D-R 320
Dust monitor
The new generation stray light dust
monitor for low to medium dust
concentrations
●● Continuous measurement The new DURAG dust monitor D-R 320 is based ●● Measuring head
●● Easy installation on standard flange on the back-scattered light principle. The light ●● Mounting flange
●● Easy start-up without adjustment of a red laser diode illuminates the dust parti- ●● Supply unit with integrated purge air supply
●● Automatic background compensation with- cles in the measuring volume of the flue gas ●● Universal operation unit D-ISC 100
out light absorber duct. The light scattered backward by these ●● Service software D-ESI 100 incl. USB-stick
●● Automatic control functions particles is detected and evaluated. and cable
●● Integrated purge air monitoring and purge The D-R 320 does not require a light trap. The
air control background light in the stack is detected by Options
●● Minimum maintenance means of a special optical system with dual de-
●● Remote access possible tector and automatically compensated. ●● Weather protection covers
●● Digital interface according to VDI 4201-3 ●● Fully integrated failsafe shutter as protection
for the measuring device in case of a purge
Applications air failure
S1:D-FL 220
report 936/21217455/A
S1.1:D-FL 220 - Speed
3.6
m/s
●● MCERTS
3
D-R 300 D-R 300-40
Measuring principle
Measuring device for
The D-R 300 / D-R 300-40 meters operate ac-
smoke spot number / cording to the scattered light method. The
modulated light from a Halogen lamp illumi-
dust concentration nates the dust particles in the exhaust duct. The
scattered light reflected from these particles is
D-R 300: Extremely sensitive device measured and assessed.
for measuring smoke spot number.
Specifications
D-R 300-40: Especially sensitive D-R 300
measuring device for the smallest
●● Measuring range: smoke spot number 0-3.
concentration of dust, in particular
Limit value II can be set as delayed discon-
in waste incineration plants. nected contact
●● Calibration: VDI 2066, part 8.
Features
D-R 300-40
●● In-situ measurement directly in the flue gas
flow ●● Minimum measuring range 0-1 mg/m3 dust
●● Automatic system tests and correction of concentration. Other measuring ranges up
measured values to 300 mg/m3 can be set (optional automatic
●● Self-calibration in 4-h cycle switching of measuring ranges 1:3:9)
●● Optics and electronics in a hermetically ●● Calibration: EN 13284-1
sealed unit - no smoke gas can enter device
●● Maintenance-friendly, thanks to optimal
purge air conduction in front of the heated
optical end plates System components quick-closing shutter
(optional)
●● Direct access to all parameters via the oper-
measuring head
ator display ●● Measuring head
●● Automatic measuring range selection in ●● Mounting flange
control
accordance with waste incineration directive ●● Control and display unit light and
display
in relation 1:3:9* ●● light trap(s) trap
unit
●● Purge air unit
Applications
Options
●● Smoke spot number measurement in furnac-
es designed for light fuel oil ●● Automatic measuring range selection for
●● Fine dust measurements in processes dust measurement in accordance with
●● Waste incineration waste incineration directive (D-R 300-40)
●● Filter monitoring and emission-value ●● Weather protection covers
measuring in waste incineration and power ●● Quick-closing shutter to protect measuring
plants* device in the event of failure of the purge purge air unit
air supply
Approvals ●● Halar flange coating
4
D-R 290
Optical opacity /
dust monitor
Standard system for plants with
small to medium dust concentra-
tions
●● In-situ measuring procedure, continuous The device operates using the double-pass ●● Bus interface, e.g. Modbus or similar
measurement method according to the auto-collimation prin ●● Automatic quick-closing shutters to protect
●● Semi-conductor source with long service life ciple. The light beam traverses the measuring the measuring head and the reflector in the
●● Super-wide band diode (SWBD), which pro- distance twice. The attenuation of the light event of failure of the purge air
vides more stable measuring results in com- beam by the dust content in the measuring sec- ●● Weather protection covers, for outdoor in-
parison to devices with conventional LEDs tion is measured and evaluated stallation
●● Powerful microprocessor technology ●● Explosion proof design for EEx p, Zone 1 or
●● Measured value display on LC display in System components Zone 2
opacity, extinction or in mg/m3 ●● With an additional display unit at the meas-
●● Automatic function tests with correction of ●● Mounting flanges uring location, the control and display unit
measured values in relation to soiling ●● Measuring head can be installed in up to 1000 m distance
●● Optics and electronics in a hermetically ●● Reflector away
sealed unit – no smoke gas can enter device ●● Control and display unit ●● Temperature compensation through addi-
●● Easy adjustment without additional equip- ●● Purge air unit tional analogue input
ment ●● Special model for measuring distances up to
●● Low-maintenance thanks to optimal purge 18 m with 2 purge air units
air conduction ●● Filter set for sensitivity and linearity control
optical reflector
measuring unit
Applications
Approvals
purge air unit
●● Suitability-tested by the TÜV Cologne,
test report 936/801017 measurements opacity, extinction detection limit 0.75% @ extinction 0–0.1
●● Approved and certified acc. to EN 15267-3 switchable opacity: 0–20% ... 0–100% reference point <0.4% of measuring range/month
●● MCERTS measuring ranges extinction: 0–0.1 ... 0–1.6 drift
dust: 0–80 mg/m3 ...
0–4000 mg/m3 1)
measuring transmission zero point drift <0.4% of measuring range/month
principle
flue gas above dew point up to 250°C, supply voltage 95–264 VAC, 47–63 Hz, 30 VA
temperature optional up to 1000°C, depending
on application
flue gas pressure -50 up to +20 hPa, dimensions measuring head
optional higher (h × w × d) 363 × 185 × 398 mm
duct diameter 1 up to 12 m, weight 7 kg
optional up to 18 m
ambient -20 up to +50°C, remarks 1)
ith reference to one meter of
w
temperature optional higher path length after gravimetric
calibration
protection IP65, Ex optional purge air supply
measuring outputs 2× 0/4–20 mA / 500 Ohm, manual purge air quantity approx. 80 m3/h
or automatic measuring range
switching, optional Modbus RTU,
Profibus DP
digital outputs 6 programmable relay outputs, supply voltage 115/230 VAC, 50/60 Hz,
permissible load 48 V / 0.5 A 0.37 / 0.43 kW
digital inputs 6 programmable potential free dimensions 350 × 550 × 500 mm
inputs (h × w × d)
weight 12 kg
accuracy <1% of measuring range protection IP55
5
D-R 220
●● Non-compliant device for smaller plants Models ●● Neutral density filters for linearity check
●● Heating stations, power stations ●● Sighting scope
●● Boiler plants in industry, barracks, hospitals, ●● System 1: for measuring sections up to ●● Display and operating unit D-ISC 100
schools 3.25 m ●● Service software D-ESI 100 incl. USB-stick
●● Dust extraction and filter plants ●● System 2: for measuring sections from and cable
●● Process monitoring 2.75 m up to 10 m
●● Filter monitoring
6
D-R 800
Dust monitor
Innovative measuring device with
laser technology to monitor small to
medium dust emission according to
the new European regulations
●● Integrated display: Measuring value, The D-R 800 device works according to the prin- ●● Measuring lance
threshold value, parameter in probe ciple of forward scattering. The concentrated ●● Supply unit with integrated purge air supply
●● In-situ measuring procedure with continu- and modulated light of a laser diode penetrates ●● Mounting flange 130 / 240 / 500 mm
ous measurement the measuring volume. The forward-scattered
●● High sensitivity light largely reflected from dust particles is Options
●● Easy installation on one side of the duct measured and assessed.
●● Can also be deployed in thick-walled stone/ ●● Weather protection cover
insulated channels ●● Temperature compensation through addi-
●● Long lifetime, as there are no moving tional analogue input
parts inside the duct ●● Hastelloy probe
●● Probe with corrosion resistant nano-tech
coating
●● Hermetically sealed electronic housing
against exhaust gas
●● Parameterisation and operation with key- supply unit with
board plus easily readable display directly on integrated purge air
supply
device or via bus interface
●● Automatic function test with soiling correc-
measuring lance evaluation unit
tion
●● Two analogue outputs with adjustable
measuring ranges
●● Automatic switching of measuring ranges
according to waste incineration directive
Applications RS 485
and
ana-
logue
●● Power stations current
●● Cement plants, the metallurgy and wood output
Approvals
7
D-R 820 F
Approvals injector
exhaust
8
F- 904-20
Features
●● 14C emitter and detector (Geiger-Müller
●● Automatic zero correction counter)
●● Pre-calibrated, unaffected by particle size, ●● Sample gas cooler
colour or moisture ●● PLC control, also for calculating the concen-
●● Sample gas flow regulated at 1 - 3 m3/h tration from the dust content
●● Isokinetic sampling
●● Optional dilution sample probe for high dust Options
concentrations or after wet scrubbers Measuring principle
●● Dust collection support function for heavy ●● Special design F-904-20/BFG for measure-
metal analyses Determination of the dust concentration by ment of the dust concentration in toxic and
●● Special model with measuring chamber measuring the absorption of beta rays emitted explosive blast-furnace or converter gas with
purging and CO-TLV monitoring during dust by a radioactive emitter by particles collected shut-off valves for the sample gas during
monitoring of blast furnace gas from an exhaust gas flow. filter transport and with purge gas (usually
nitrogen) for line back purging. Additional
Applications System components gas sensors need to be installed in the de-
ployment area of the device which close all
●● Coal and oil-fired power stations ●● Heated sample probe (material 1.4571 or connections to the process gas and trigger
●● Waste incineration plants (municipal waste, titanium), with or without dilution an alarm.
industrial waste and hazardous waste) ●● Heated sample line in 1.4571 ●● Filter tape printer and protective sheet for
●● Sewage sludge incineration plants ●● Filter tape in gas-tight filter holder supporting heavy metal analyses.
●● Emission dust measurement after wet scrub-
bers or in very wet exhaust gases sample probe, nozzle
●● Heavy metal analysis pressurized air
●● Measurement of very low dust concentra- PLC
tape-filter printer
tions in emissions (option) 4–20 mA
●● Emission dust measurement in inaccessible STATI
cover foil counter tube
flues with small diameter (option)
C-14 source
●● Dust concentration measurements in pro- total flow
vacuum pump
cess applications filter housing with bypass total flow dilution
controller Venturi gas
nozzle Venturi
Approvals supply reel nozzle
9
D-FW 230 231 240/Ex
Filter monitor
Triboelectric filter monitor for
efficiency monitoring after filter
plants and for continuous dust
measuring in dry emissions
●● Compact and rugged design The filter monitor uses the triboelectric effect D-FW 231 measuring probe
●● Good price/performance ratio to determine dust loads in flowing gases. The
●● Ideal for monitoring bag filters electrical charge which the dust particles expe- ●● With complete electronics in the probe
●● Minimal maintenance required rience due to friction is picked up by a probe ●● Probe rod length 1000 mm
●● Early detection of filter malfunctions protruding into the dust channel and converted ●● Fitted via 1“(G1) thread
●● Savings in cost, as no preventative filter ex- into a measuring signal by electronics. The
change is necessary. measuring signal is proportional to the dust D-FW 230 filter monitor
concentration and is calibratable at a constant
Applications gas speed. ●● D-FW 231 measuring probe
●● Probe rod length 1000 mm
●● Power stations ●● D-FW 230-B control unit with digital display
●● Bag filter plants of all types 115/230V 50/60 Hz.
●● Dust extraction plants in the production System components
industry
●● Waste incineration plants
●● Crematoriums
✖ Not suitable for use directly behind electro
probe control unit
static precipitators.
Approvals
Options
10
D-RX 250
Combined
probe sensor
Single rod measurement probe for
simultaneous measurement of
- Dust concentration [mg/Nm³]
- Volume flow [Nm³/h]
- Temperature [°C]
- Absolute pressure [hPa]
●● Only one probe / installation opening in the ●● The tribo probe measures the electric charge ●● The temperature is measured directly in
exhaust gas channel of the incident particles. the centre of the flue gas flow in a separate
●● Compact design, no moving parts, no con- ●● The measurement of the volume flow is chamber within the probe with a tempera-
sumable parts based on the mechanical action principle. ture sensor.
●● Continuous conversion to normalised dust The probe has two separate chambers, be- ●● Dust concentration is calculated from
concentration in mg/Nm3 and to normalised tween which a differential pressure builds up the triboelectric measuring signal and the
volume flow in Nm3/h under flow. volume flow. The raw data that are also
●● LCD display in mg/Nm3, Nm3/h,°C and hPa, ●● The absolute pressure in the flue gas is measured for gas temperature and absolute
one analogue output for each measurement measured by a pressure transmitter in one pressure are used to calculate the standard
value chamber of the probe dust concentration and the standard volume
●● Parameterization at the control unit without flow (wet).
the need of a PC or other tools
●● Remote connection of control and evalu-
System components
ation unit via two-wire bus interface up to probe transmitter differential control and
pressure evaluation unit
1000 m. transducer
Applications
11
D-RC 120
dust measurements
notebook
drying tower
external
sensor unit pump
12
HM- 1400 TRX
●● Maintenance-free (6 months) dry reactor In the HM 1400 TRX total ●●sampling probe
●● High operational safety mercury analyser the sam- ●●sampling line
●● Easy maintenance ple gas is converted into ●●measuring device.
●● Low cross sensitivities mercury vapour by a com-
●● Easily legible LC display bination of thermal and dry Options
●● Three month maintenance interval chemical treatment. This is
then continuously measured ●●Larger measuring range
Applications in a photometer. The probe with dilution device
gas flow is measured after a gas cooler at 2°C. ●● Side-mounted cooling device
●● Waste incinerations (municipal waste, indus- The concentration is calculated and displayed as ●● Integrated system to generate reference gas
trial waste, hospital waste) „dry flue gas“. ●● Heated sample pipe 0.6 m, 1.0 m, 1.5 m;
●● Sewage sludge incineration 600 VA, 800 VA, 1200 VA.
●● Hazardous waste incineration
●● Steel plants with scrap metal preparation
●● Contaminated soil burning plants
●● Crematoriums
●● Mercury mines and refineries
●● Fluorescent light bulb recycling plants heated
sample probe
Approvals
pump
●● Suitability-tested by the TÜV Hamburg, thermocatalytic
reactor Hg-photometer
test report GMT007/8000632287 from zero gas
30.06.11 filter liquid watchdog
●● Approved and certified acc. to EN 15267-3 calibration reactor
option
stack
reference condensate
standard
13
F- 701-20
Approvals Bypass-Valve
14
D-ISC 100 D-ESI 100
D-ISC 100
Universal operating and display
unit in stainless steel field hous-
ing for the new generation sensors
from DURAG, e.g.
D-FL 100, D-FL 220, D-R 220 or
D-R 320
●● Easy set-up and automatic detection of up to The universal operating and display unit D-ISC ●● 4 slots for expansion modules:
eight connected sensors 100 allows the connection of up to eight meas- - Modbus RTU interface acc. to VDI4201-3
●● Uniform operation of various sensors uring devices as for instance dust and volume - 4 analogue outputs 0/4-20mA / 500 Ohm
●● Large LC Display for measured value display flow monitors. - 4 analogue inputs 0-20mA/100 Ohm
●● Comfortable operation and handling via The D-ISC 100 offers access via the built-in - 4 digital inputs
keypad panel, a connected PC or remote access via the - 4 relay outputs 48 V/0.5A
●● USB interface for local device operation intranet/internet and easy parameterization of
●● Remote support via intranet/ internet the connected DURAG devices. ●● Interface converters, e.g. for
●● Modular design, expansion slots and slot for The display allows direct view of the current - Profibus DP
external converter available measuring values. ●● Software modules
●● Easy update via SD memory card
Analogue output 0/4-20 mA / 500 Ohm Housing Stainless steel 304,
●● Power supply 24 VDC/2A for one directly RAL 5017
connected sensor Digital outputs 3 relay outputs 48 V /0.5 A Dimensions (h × w × d) 122× 330 × 220 mm
Digital input 1 digital input, operation Weight 5 kg
via potential-free contact
Ambient temperature -20 up to +50 °C, Protection rating IP65
-40 up to +60 °C optional
Service-Interface USB, TCP/IP Supply voltage 90–264 VAC, 48–62 Hz
D-ESI 100
Service- and Parameterization
Software
Features
Application Requirements
D-ESI 100 is a graphical interface for operation, ●● PC with Microsoft Windows® operating
parameterisation and management of the con- system 7 or 8
nected sensors. ●● USB interface
D-ESI 100 offers access to the parameters of the ●● Serial interface RS485
connected sensors via USB interface, the DURAG ●● Ethernet interface
Modbus interface or via Modbus TCP.
15
D-FL 100
Volume flow
measuring system
Measuring system to measure flow
rate in dry emissions with a probe
using the differential pressure prin-
ciple
●● Measurement of gas velocity The D-FL 100 measuring system operates ac- ●● Mounting flange
●● Calculation of volume flow at standard con- cording to the differential pressure principle. ●● Flow probe
ditions The probe has two separate chambers, between ●● Counter-support
●● Adjustable parameters which the flow builds up a differential pressure. ●● Differential pressure transducer
●● Automatic back purging device (optional) Taking account of the other flow parameters ●● Cross-over cock
●● Versions with or without counter-support such as, e.g. absolute pressure and temperature, ●● Probe adapter
and for point measurement. the volume flow can be converted from opera- ●● Microprocessor evaluation unit D-FL100-20
●● Three month maintenance interval ting to standard conditions with the evaluation ●● Absolute pressure transducer
unit. ●● Temperature transducer
Applications
Models Options
●● Volume flow measurement at high temper-
atures ●● D-FL 100 probe assembly ●● Display and control unit D-ISC 100
●● Plants with large or small flue cross-sections with assembly of measuring transducer on ●● Service software D-ESI 100
●● Volume flow measurement at high pressure the probe (not for probe 3) ●● Weather protection covers
●● D-FL 100 hose assembly ●● Automatically controlled back purging de-
Approvals with the measuring transducer connection vice
via hose line ●● Special designs in other materials for appli-
●● Suitability-tested by the TÜV Cologne, cations with particularly aggressive exhaust
test report 936/21218492/A Probes gases or high gas temperatures
●● Approved and certified acc. to EN 15267-3 ●● dP-transducer in Ex-version
●● MCERTS ●● Probe 1: 0.4–2 m
●● Probe 2: up to 4 m
differential pressure transducer
●● Probe 3: up to 8 m
flow 4 ... 20 mA
evaluation
4 ... 20 mA unit
4 ... 20 mA
cross-over cock
absolute temperature
pressure transducer
transducer
flow probe
flow direction
measurements flue gas velocity, volume flow digital outputs 2 relay outputs,
permissible load 48 V / 0.5 A
measuring ranges 0–3000000 m3/h / 2–50 m/s accuracy <2% of measuring range
measuring differential pressure detection limit <3 m/s
principle
flue gas above dew point up to 450°C, reference point <0.5% of measuring range/month
temperature optional up to 850°C drift
flue gas pressure ±200 hPa, optional higher zero point drift <0.5% of measuring range
duct diameter 0.4–8 m supply voltage 90 / 264 VAC, 50–62 Hz, 100 VA
optional 18–32 VDC
ambient -20 up to +50°C dimensions probe: 380 × 160 × (300 + probe
temperature (h × w × d) length) mm
protection IP65, Ex optional weight 32 kg + 6,8 kg/m probe length
measuring outputs 0/4–20 mA / 500 Ohm, Modbus purge air supply 6–8 bar for back purging if
RTU, RS485, acc. to VDI 4201-3 necessary
16
D-FL 220
Volume flow
measuring system
Measuring system for ultra-sonic
measuring of flow and volume flow,
especially for wet and aggressive
smoke emissions (waste incinera-
tion)
●● In-situ measuring method The D-FL 220 measuring system works accord- ●● Temperature transducer
●● Measurement possible below dew point and ing to the acoustic transit time differential ●● Absolute pressure transducer
for high dust concentrations method as well. The flow velocity resp. volume ●● Universal display and control unit D-ISC 100
●● Continuous measurement of normal volume flow of the waste gas is precisely calculated ●● D-ESI 100 Service- and Parameterization
flow and gas velocity from the transit time difference dependent on Software
●● Automatic zero point and reference point the direction.
control
●● New design, digital signal processing System components
●● D-FL 200 compatible follow-up model
●● Remote access possible, digital interface ac- ●● 2 Measuring heads
cording to VDI 4201-3 ●● 2 Purge flanges (material 1.4571)
●● Operation with or without control unit ●● 2 Mounting flanges (Mat. 1.4571, FRP)
●● Very low maintenance ●● Purge air unit for cleaning and cooling the
sensors
Applications ●● Terminal Box for power supply of the sensors
purge air
measurements flue gas velocity, volume flow 1), detection limit <0.3% of measuring range
temperature
measuring ranges 0–3,000,000 m3/h / 0–40 m/s reference point <0.3% of measuring range/month
0–400°C drift
measuring acoustic propagation delay zero point drift <0.2% of measuring range/month
principle
flue gas 0–300°C, optional higher supply voltage 24 VDC, 0.5 A
temperature
flue gas pressure -50 up to +20 hPa, optional higher dimensions standard measuring head:
(h × w × d) 190 Ø × 570 mm
duct diameter 0.5–13 m, temperature dependent weight 17 kg
ambient -20 up to +50°C remarks 1)
ptional pressure and
o
temperature measuring head -40 up to 70°C temperature correction
protection IP65 purge air supply
measuring outputs 0/4–20 mA / 400 Ohm, purge air quantity approx. 80 m3/h
Modbus RTU bi-directional
digital outputs 2 relay outputs, supply voltage 115 / 230 V, 50 / 60 Hz,
permissible load 48 V / 0.5 A 0.37 / 0.43 kW
digital inputs none dimensions 350 × 550 × 500 mm
weight 12 kg
accuracy <2% protection IP55
17
D-EMS 2000
m US
A
EL
R
Me ing
>3 mor
2d y
TC
ay
P
R s
/I
Me ing
P
>3 mor
4- OD fib
M ro PC N
20 B us
2d y
P O A
m US
ay
A
s
EL
Pe (A
..8
D
rs ut
-M
1.
on h
S
50
in rit
0
K
C y)
E
h
o
ar
D C
-E li
g
e
M en
S t
20
00
w
w
D C
-E li
w
M en
S t
R
Me ing
20
00
>5 mor
Ind yea y
iv rs
v idu
Proalue al -
D C
-E li
toc s
M en
S t
ols
20
00
Sy
st
Ra em
id
1
Sy -
st EM
em
D
Ba
c
W 2
on kup
or 0
HD ext
ks 0
S
/SS .
ta 0
D
ti
TC
on
P
/I
P
D P
C S
F7
G
18
D-EMS 2000 CS
4- OD s, E
20 B la
M bu C
Pr
A
ofi O
m S n,
u
A
th
U
or
P
it
y
D C
-E li
R
M en
6 Ying M
S t
20
w
00
ea e
w
+ rs mo
Features
w
30 ProtInt, Dry
D C
-E li
M en
Da oco ay
S t
Ba
20
cku y
+ 1s 1mls
00
o p
HD n
●● Compact system, no additional evaluation /SS s in
D C
D
D-
-E li
M en
EM
S t
PC required
20
S2
00
●● Modern flash memory technology instead of 00
0C
S
hard disks
●● Independently operating module for acqui-
sition, long-term storage, calculation and
visualisation of environmental and process
D P
C S
TC
F7
data
P
/I
P
●● Instrument for monitoring officially pre- Main features
scribed limit values with automatic logging
●● Continuous monitoring of 1 to 12 compo- ●● Windows based and certified D-EMS 2000 software
nents connected via bus communication or ●● All modules from the D-EMS 2000 system are usable
hard wired ●● Excellent cost/performance ratio
Options
Applications
Computer Intel based Dual core PC with Windows 7 & 8, 2 GB Ram and > 100 GB SSD
inputs / outputs up to 3 cards:
combined card: 4 AI / 8 DI / 2 AO / 4 DO
input card: 8 AI / 15 DI
output card: 8 AO
output card: 16 DO
bus system connections Modbus RTU / TCP, PROFIBUS, Elan, OPC UA
analogue-/digital inputs: 12/24
analogue-/digital outputs: 12/24
interfaces 1x VGA, 2x USB, 1x RJ 45, 3x serial (RS232 or RS485), BNC for DCF 77- radio clock
ambient temperature 5 up to +40°C
protection IP 20
operating voltage 115/230 VAC / 50/60 Hz / 100 VA
19
DURAG Sales and Marketing DURAG Niederlassung Nord DURAG Niederlassung West DURAG Niederlassung Süd
GmbH & Co. KG Kollaustraße 105 An der Pönt 53a Weidenweg 16
Kollaustraße 105 22453 Hamburg, Germany 40885 Ratingen, Germany 73087 Bad Boll, Germany
22453 Hamburg, Germany Tel. +49 40 55 42 18-0 Tel. +49 2102 74 00-0 Tel. +49 7164 912 25-0
Tel. +49 40 55 42 18-0 Fax +49 40 58 41 54 Fax +49 2102 74 00 28 Fax +49 7164 912 25-50
Fax +49 40 58 41 54 E-Mail: durag-nord@durag.de E-Mail: durag-west@durag.de E-Mail: durag-sued@durag.de
E-Mail: info@durag.de
DURAG Niederlassung Ost
Halsbrücker Straße 34
09599 Freiberg, Germany
Tel. +49 3731 30 04-0
Fax +49 3731 30 04-22
E-Mail: durag-ost@durag.de
DURAG GmbH DURAG data systems GmbH DURAG process & systems DURAG Siena do Brasil Ltda
Kollaustraße 105 Kollaustraße 105, technology gmbh Rua Vinte e Dois de Agosto, 66
22453 Hamburg, Germany 22453 Hamburg, Germany Kollaustraße 105 Diadema - SP
Tel. +49 40 55 42 18-0 Tel. +49 40 55 42 18-3000 22453 Hamburg, Germany 09941-530 Brazil
Fax +49 40 58 41 54 Fax +49 40 55 42 18-3099 Tel. +49 40 55 42 18-0 Tel. +55 11 4071-5050 r.28
E-Mail: info@durag.de E-Mail: info@durag-data.de Fax +49 40 58 41 54 Fax +55 11 4077-1718
E-Mail: info@durag-process.de E-Mail: info@duragsiena.com.br
DURAG Brazil DURAG France S.a.r.l. DURAG, Inc., USA DURAG India Instrumentation
DURAG Siena do Brasil Ltda Parc GIP Charles de Gaulle 1355 Mendota Heights Road Private Limited
Rua Vinte e Dois de Agosto, 66 49, rue Léonard de Vinci, BP 70166 Suite 200 #27/30, 2nd Main Road
Diadema - SP 95691 Goussainville CEDEX, Mendota Heights Industrial Town, Rajajinagar
09941-530 Brazil France MN 55120, USA Bengaluru 560 044, India
Tel. +55 11 4071-5050 r.28 Tel. +33 1 301 811 80 Tel. +1 651 451-1710 Tel. +91 80 2314 5626 / 4215 1191
Fax +55 11 4077-1718 Fax +33 1 393 383 60 Fax +1 651 457-7684 Fax +91 80 2314 5627
E-Mail: info@duragsiena.com.br E-Mail: info@durag-france.fr E-Mail: durag@durag.com E-Mail: info@duragindia.com
©DURAG GROUP 08/2014 · Subject to change without notice
DURAG Instrumentation DURAG Italia S.r.l. DURAG Japan Office DURAG Korea Office
(Shanghai) Co., Ltd. Via Carlo Panseri, 118 c/o TMS Planning Inc. RM #1131, Manhattan Building,
Room 706, Dibao Plaza, No. 3998 CIM uffici, P. secondo 291-2 Umena, Mishima-shi, 36-2, Yeouido-Dong,
Hongxin Rd., Minhang District, 28100 Novara Shizuoka-ken, Yeongdeungpo-Gu, Seoul,
Shanghai, 201103 PR China Italy 411-0816 Japan Korea
Tel. +86 21 60732979-206 Tel. +39 0321 679569 Tel. +81 55 977 3994 Tel. +82 2 761 8970
Fax +86 21 60732980 Fax +39 0321 474165 Fax +81 55 977 3994 Fax +82 2 761 8971
E-Mail: info@durag-cn.com E-Mail: info@durag.it E-Mail: info@durag.jp E-Mail: info@durag-group.co.kr
www.durag.de
Fax +7 499 4180091 Fax +44 1785 760 014
E-Mail: info@durag-group.ru E-Mail: durag.uk@durag.de