Product Overview

Emission Monitoring
Ambient Monitoring
Environmental and Process Data
Management Systems

smart solutions for combustion and environment


Devices for measuring emissions and immissions
Measurement Dust / Opacity Dust Soot Dust Dust Dust Total Ambient
Mercury Dust
Measuring Transmission Backward Scattering Forward Scattering Tribo Beta UV Photo­ Beta
principle meter
DURAG Group D-R 220 D-R 290 D-R 320 D-R 300-40 D-R 300 D-R 800 D-R 820 F D-RX 250 F-904-20 HM-1400 F-701-20
Device TRX
TÜV ● ● ● ● ● ● ● ● ● ●
DIN EN 15267-3 ● ● ● ● ● ●
US EPA ● ● ● ●
GOST / EAC ● ● ● ● ● ● ● ● ● ●
MCERTS ● ● ● ● ● ● ●
Korean ● ● ●
in-situ ● ● ● ● ● ● ● ●
extractive ● ● ● ●
Automatic zero ● ● ● ● ● ● ● ● ● ●
and control point
Automatic soiling ● ● ● ● ● ● N/A N/A N/A N/A
correction
Fail safe shutters ● ● ● ● N/A N/A N/A N/A
Range switching ● ● opt. ● ● ●
Remote control ● ● ● ● ●
unit
Calibratable in mg/m3 mg/m3 mg/m3 mg/m3 smoke spot mg/m3 mg/m3 mg/m3 mg/m3 mg/m3 mg/m3
wet wet wet wet number wet wet wet
Measuring 0-0.2...1.6 0-0.1...1.6 0–5...200 0-1...30 3 RZ 0-10...200 0-15...100 0-2...100 0-1...0-1000 0-45…500 0-0.1…10
ranges Ext Ext mg/m3 mg/m3* mg/m3 mg/m3 mg/m3 wet mg/m3 µg/Nm3 mg/m3
0-20...100%
Detection limit 20 mg/m3 10 mg/m3 0,07 mg/m3 0.01 mg/m3 0.06 RZ 0.2 mg/m3 0.2 mg/m3 0.01 mg/m3 0.5 µg/Nm3 N/A
@ stack Ø 1 m
Detection limit 8 mg/m 3
2 mg/m 3
0,07 mg/m 3
0.01 mg/m 3
0.06 RZ 0.2 mg/m 3
0.2 mg/m 3
0.01 mg/m 3
0.5 µg/Nm 3
N/A
@ stack Ø 5 m
Sample ● ●
collection/ heavy
metal analysis
*with measuring range switching up to approx. 300 mg/m3

Comparison of emission dust monitors according to application criteria


Measuring range mg/m3 0 10 100 200 1000
D-R 300-40
D-R 320
D-RX 250
D-R 820 F
D-R 800
D-R 290
D-R 220
Duct diameter 0.3 m 1m 6m 10 m 18 m
D-RX 250
D-R 300-40
D-R 220
D-R 320
D-R 800 / 820 F
D-R 290
Exhaust gas temperature dew point 50°C 100°C 200°C 300°C 400°C 500°C 600°C
D-R 820 F
F- 904-20
D-R 320
D-R 220
D-R 290
D-R 300-40
D-R 800
D-RX 250
Relative humidity 100% 80% 0%
tribo
optical
extractive

Option

2
D-R 320

Dust monitor
The new generation stray light dust
monitor for low to medium dust
concentrations

Features Measuring principle System components

●● Continuous measurement The new DURAG dust monitor D-R 320 is based ●● Measuring head
●● Easy installation on standard flange on the back-scattered light principle. The light ●● Mounting flange
●● Easy start-up without adjustment of a red laser diode illuminates the dust parti- ●● Supply unit with integrated purge air supply
●● Automatic background compensation with- cles in the measuring volume of the flue gas ●● Universal operation unit D-ISC 100
out light absorber duct. The light scattered backward by these ●● Service software D-ESI 100 incl. USB-stick
●● Automatic control functions particles is detected and evaluated. and cable
●● Integrated purge air monitoring and purge The D-R 320 does not require a light trap. The
air control background light in the stack is detected by Options
●● Minimum maintenance means of a special optical system with dual de-
●● Remote access possible tector and automatically compensated. ●● Weather protection covers
●● Digital interface according to VDI 4201-3 ●● Fully integrated failsafe shutter as protection
for the measuring device in case of a purge
Applications air failure

●● Waste incineration plants


●● Cement manufacturing plants
●● Power plants with gas, oil, coal or co-firing
●● Monitoring of ventilation systems
●● Monitoring of filter systems mounting flange measuring universal supply unit
head operation unit with integrated
D-ISC 100 purge air
Approvals supply

●● Suitability-tested by the TUV Cologne, test D-ISC 100

S1:D-FL 220

report 936/21217455/A
S1.1:D-FL 220 - Speed

3.6
m/s

0.0 10.0 20.0

●● Approved and certified acc. to EN 15267-3


Status: S1.3:Normal measurement

●● MCERTS

measurements dust concentration digital outputs 2 relay outputs, permissible load


60 VDC / 30 VAC / 0.5 A
measuring ranges min: 0 … 5 mg/m3, supply voltage 24 VDC, 0.5 A
max: 0 … 200 mg/m3
measuring backward scattering dimensions 200 x 190 x 260/410 mm
principle (h x w x d)
flue gas 0 … 600°C weight 15 kg
temperature
flue gas pressure -50 … +50 hPa, optional higher supply unit
duct diameter > 0.7 m purge air supply integrated blower
ambient -40…+60°C supply voltage 115/230 VAC, 50/60 Hz,
temperature 0.37/0.43 kW
protection IP 65 dimensions 480 x 450 x 320 mm (h x w x d)
measuring outputs 0 / 4 … 20 mA / 400 Ohm, weight 12 kg
Modbus RTU bi-directional
protection IP 65

3
D-R 300 D-R 300-40

Measuring principle
Measuring device for
The D-R 300 / D-R 300-40 meters operate ac-
smoke spot number / cording to the scattered light method. The
modulated light from a Halogen lamp illumi-
dust concentration nates the dust particles in the exhaust duct. The
scattered light reflected from these particles is
D-R 300: Extremely sensitive device measured and assessed.
for measuring smoke spot number.
Specifications
D-R 300-40: Especially sensitive D-R 300
measuring ­device for the smallest
●● Measuring range: smoke spot number 0-3.
concentration of dust, in particular
Limit value II can be set as delayed discon-
in waste incineration plants. nected contact
●● Calibration: VDI 2066, part 8.
Features
D-R 300-40
●● In-situ measurement directly in the flue gas
flow ●● Minimum measuring range 0-1 mg/m3 dust
●● Automatic system tests and correction of concentration. Other measuring ranges up
measured values to 300 mg/m3 can be set (optional automatic
●● Self-calibration in 4-h cycle switching of measuring ranges 1:3:9)
●● Optics and electronics in a hermetically ●● Calibration: EN 13284-1
sealed unit - no smoke gas can enter device
●● Maintenance-friendly, thanks to optimal
purge air conduction in front of the heated
optical end plates System components quick-closing shutter
(optional)
●● Direct access to all parameters via the oper-
measuring head
ator display ●● Measuring head
●● Automatic measuring range selection in ●● Mounting flange
control
accordance with waste incineration directive ●● Control and display unit light and
display
in relation 1:3:9* ●● light trap(s) trap
unit
●● Purge air unit
Applications
Options
●● Smoke spot number measurement in furnac-
es designed for light fuel oil ●● Automatic measuring range selection for
●● Fine dust measurements in processes dust measurement in accordance with
●● Waste incineration waste incineration directive (D-R 300-40)
●● Filter monitoring and emission-value ●● Weather protection covers
measuring in waste incineration and power ●● Quick-closing shutter to protect measuring
plants* device in the event of failure of the purge purge air unit
air supply
Approvals ●● Halar flange coating

●● Suitability-tested by the TÜV Cologne,


test report 936/800002
●● Approved and certified acc. to EN 15267-3
measurements smoke spot number (D-R 300) detection limit <1% measuring range
●● Suitability-tested by the TÜV Cologne, dust concentration (D-R 300-40)
test report 936/801004* measuring ranges D-R 300: reference point <0.2% of measuring range/month
●● MCERTS smoke spot number 1–3 (5) drift
*D-R 300-40 D-R 300-40: dust concentration
0–1 mg/m3 ... 0–30 mg/m3 1),
optional 0–300 mg/m3 with range
switching
measuring back scattering zero point drift <0.2% of measuring range/month
principle
flue gas above dew point up to 320°C, supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA
temperature optionally higher
flue gas pressure -50 up to +20 hPa dimensions measuring head
(h × w × d) 565 × 310 × 200 mm
duct diameter 0.3 to 4 m weight 18 kg
ambient -20 up to +50°C remarks 1)
after gravimetric calibration
temperature
protection IP65 purge air supply
measuring outputs 2× 0/4–20 mA/500 Ohm, optional purge air quantity approx. 80 m3/h
measuring range switching
digital outputs 3 relay outputs, supply voltage 115 / 230 VAC, 50 / 60 Hz,
permissible load 48 V / 0.5 A 0.37 / 0.43 kW
digital inputs 1 potential free input dimensions
(h × w × d) 350 × 550 × 500 mm
weight 12 kg
accuracy <1% of measuring range protection IP55

4
D-R 290

Optical opacity /
dust monitor
Standard system for plants with
small to medium dust concentra-
tions

Features Measuring principle Options

●● In-situ measuring procedure, continuous The device operates using the double-pass ●● Bus interface, e.g. Modbus or similar
measurement method according to the auto-collimation prin­ ●● Automatic quick-closing shutters to protect
●● Semi-conductor source with long service life ciple. The light beam traverses the measuring the measuring head and the reflector in the
●● Super-wide band diode (SWBD), which pro- distance twice. The attenuation of the light event of failure of the purge air
vides more stable measuring results in com- beam by the dust content in the measuring sec- ●● Weather protection covers, for outdoor in-
parison to devices with conventional LEDs tion is measured and evaluated stallation
●● Powerful microprocessor technology ●● Explosion proof design for EEx p, Zone 1 or
●● Measured value display on LC display in System components Zone 2
­opacity, extinction or in mg/m3 ●● With an additional display unit at the meas-
●● Automatic function tests with correction of ●● Mounting flanges uring location, the control and display unit
measured values in relation to soiling ●● Measuring head can be installed in up to 1000 m distance
●● Optics and electronics in a hermetically ●● Reflector away
sealed unit – no smoke gas can enter device ●● Control and display unit ●● Temperature compensation through addi-
●● Easy adjustment without additional equip- ●● Purge air unit tional analogue input
ment ●● Special model for measuring distances up to
●● Low-maintenance thanks to optimal purge 18 m with 2 purge air units
air conduction ●● Filter set for sensitivity and linearity control
optical reflector
measuring unit
Applications

Plants in which the dust concentration quantity


needs to be measured, e.g.:
●● Furnace plants with semi-anthracite coal,
brown coal, fuel oil and combined heating
●● Converter plants, asphalt mixing plants
●● Plants for cement manufacture.
display unit

Approvals
purge air unit
●● Suitability-tested by the TÜV Cologne,
test report 936/801017 measurements opacity, extinction detection limit 0.75% @ extinction 0–0.1
●● Approved and certified acc. to EN 15267-3 switchable opacity: 0–20% ... 0–100% reference point <0.4% of measuring range/month
●● MCERTS measuring ranges extinction: 0–0.1 ... 0–1.6 drift
dust: 0–80 mg/m3 ...
0–4000 mg/m3 1)
measuring transmission zero point drift <0.4% of measuring range/month
principle
flue gas above dew point up to 250°C, supply voltage 95–264 VAC, 47–63 Hz, 30 VA
temperature optional up to 1000°C, depending
on application
flue gas pressure -50 up to +20 hPa, dimensions measuring head
optional higher (h × w × d) 363 × 185 × 398 mm
duct diameter 1 up to 12 m, weight 7 kg
optional up to 18 m
ambient -20 up to +50°C, remarks 1)
 ith reference to one meter of
w
temperature optional higher path length after gravimetric
calibration
protection IP65, Ex optional purge air supply
measuring outputs 2× 0/4–20 mA / 500 Ohm, manual purge air quantity approx. 80 m3/h
or automatic measuring range
switching, optional Modbus RTU,
Profibus DP
digital outputs 6 programmable relay outputs, supply voltage 115/230 VAC, 50/60 Hz,
permissible load 48 V / 0.5 A 0.37 / 0.43 kW
digital inputs 6 programmable potential free dimensions 350 × 550 × 500 mm
inputs (h × w × d)
weight 12 kg
accuracy <1% of measuring range protection IP55

5
D-R 220

Optical dust and


opacity meter
Monitoring dust emissions on
smaller plants and in process ap-
plications

Features Measuring principle optical reflector


measuring unit
●● In-situ measurement directly in the flue gas The device operates using the double-pass
flow method according to the auto-collimation prin­
●● Digital operation with microprocessor ciple. The light beam traverses the measuring
●● Adjustable limit value distance twice. The attenuation of the light
supply box
●● 2 contact switch outputs beam by the dust content in the measuring sec-
●● Measuring value integral tion is measured and evaluated.
4/15/64 seconds
●● Internal event memory System components
●● PC-interface for easy maintenance
●● Modbus RTU interface ●● D-R 220 measuring head
●● Measurement results shown as opacity or ●● 2 reflectors for measuring distances 0.4 to
extinction 3.5 m and 3 to 10 m
●● No weather protection covers needed ●● Mounting flanges
●● Supply box with purge air unit
Applications ●● Zero point reflector Options

●● Non-compliant device for smaller plants Models ●● Neutral density filters for linearity check
●● Heating stations, power stations ●● Sighting scope
●● Boiler plants in industry, barracks, hospitals, ●● System 1: for measuring sections up to ●● Display and operating unit D-ISC 100
schools 3.25 m ●● Service software D-ESI 100 incl. USB-stick
●● Dust extraction and filter plants ●● System 2: for measuring sections from and cable
●● Process monitoring 2.75 m up to 10 m
●● Filter monitoring

measurements opacity, accuracy <2% of measuring range


extinction
measuring ranges 0–25/50/100% OP detection limit <2% of measuring range
0–0.2 / 0.4-1.6 Ext
0-160 mg/m3
0-4000 mg/m³1) dust
measuring transmission supply voltage 24 VDC, 0.4 A
principle
flue gas above dew point up to 200°C, dimensions measuring head
temperature optional up to 500°C, (h × w × d) 160 × 150 × 314 mm
depending on application
flue gas pressure -50 up to +10 hPa, weight measuring unit 2.7 kg,
optional higher reflector 1.6 kg
duct diameter 400–10,000 mm supply box
ambient -20 up to +50°C purge air supply integrated
temperature
protection IP65 supply voltage 85–264 VAC, 46–63 Hz,
50 VA
measuring output 0/4–20 mA / 400 Ohm dimensions 210 × 300 × 380 mm
(h × w × d)
digital outputs 2 relay outputs weight 13 kg
30 VA, max. 48 V / 0.5A
protection IP54
remarks 1)
with reference to one meter of path length after gravimetric calibration

6
D-R 800

Dust monitor
Innovative measuring device with
laser technology to monitor small to
medium dust emission according to
the new European regulations

Features Measuring principle System components

●● Integrated display: Measuring value, The D-R 800 device works according to the prin- ●● Measuring lance
threshold value, parameter in probe ciple of forward scattering. The concentrated ●● Supply unit with integrated purge air supply
●● In-situ measuring procedure with continu- and modulated light of a laser diode penetrates ●● Mounting flange 130 / 240 / 500 mm
ous measurement the measuring volume. The forward-scattered
●● High sensitivity light largely reflected from dust particles is Options
●● Easy installation on one side of the duct measured and assessed.
●● Can also be deployed in thick-walled stone/ ●● Weather protection cover
insulated channels ●● Temperature compensation through addi-
●● Long lifetime, as there are no moving tional analogue input
parts inside the duct ●● Hastelloy probe
●● Probe with corrosion resistant nano-tech
coating
●● Hermetically sealed electronic housing
against exhaust gas
●● Parameterisation and operation with key- supply unit with
board plus easily readable display directly on integrated purge air
supply
device or via bus interface
●● Automatic function test with soiling correc-
measuring lance evaluation unit
tion
●● Two analogue outputs with adjustable
measuring ranges
●● Automatic switching of measuring ranges
according to waste incineration directive

Applications RS 485
and
ana-
logue
●● Power stations current
●● Cement plants, the metallurgy and wood output

industries, chemical industry etc.


●● Waste incineration plants
●● Monitoring of dust filter plants

Approvals

●● Suitability-tested by the TÜV Cologne,


test report 936/21205307/A
measurements dust concentration digital outputs 4 relay outputs, programmable,
●● Approved and certified acc. to EN 15267-3 permissible load 48 V / 0.5 A
measuring ranges 0–10 mg/m3 ... 0–200 mg/m3 1)
●● MCERTS
measuring forward scattering accuracy <1% of measuring range limit
principle
flue gas above dew point up to 350°C detection limit <0.5% measuring range
temperature
flue gas pressure -50 up to +10 hPa reference point <0.7% of measuring range/month
drift
duct diameter 0.4–8 m zero point drift <0.15 % of measuring range/
month
probe length 400 / 800 mm supply voltage 85–264 VAC, 47–63 Hz, 50 VA
(from flange)
ambient -20 up to +50°C dimensions measuring lance:
temperature (h × w × d) 160 × 160 × 600 / 1000 mm
supply unit: 380 × 300 × 210 mm
protection IP65 weight measuring lance: 7 kg
supply unit: 13 kg
measuring outputs 2× 0/4–20 mA / 500 Ohm, purge air supply integrated into supply unit
Modbus RTU (RS485)
digital inputs 2 potential free inputs, remarks 1)
after gravimetric calibration
programmable

7
D-R 820 F

Dust concentration Measuring principle


monitor for wet A defined partial current is withdrawn
gases from the exhaust gas current. This par-
tial current is continuously heated and
diluted with clean, heated air directly
Sensitive system for continuous in the sampling probe. This immedi-
extractive dust concentration ately lowers the relative moisture and
aerosols get evaporated in the heated
­measurement in accordance with
the scattered light principle probe. The partial current is optically
measured in the measuring chamber.
The signal is corrected by the meas-
ured dilution ratio and is thus a meas-
Features ure of the dust content of the exhaust
gas.
●● Compact design The system comprises a special sam-
●● Very low maintenance requirement pling probe, the laser dust monitor, a
●● In-situ measuring method with continuous gas conditioning unit (dilution, tem-
measurement pering), an injector, two fans and an
●● High sensitivity electronic evaluation unit.
●● No laborious device adjustment The sampling probe and the measuring cham-
ber form an assembly. The electronic evaluation
Applications unit and one blower for operating the injec-
tor and one for generating the diluting air are
The D-R 820 F is used for measuring dust con- System components mounted together on a rack frame.
centration in wet gases.
Potential applications e.g.: probe
●● Measurements in saturated gas downstream electronics
purge air
of desulfurization plants for probe
●● Downstream of wet cleaning plants
●● Waste incineration plants (filter optional)

●● Technological processes probe heating

Approvals injector

●● Suitability-tested by the TÜV Cologne,


test report 936/21210225/A control
valve measuring
solenoid valve chamber
●● Approved and certified acc. to EN 15267-3 measuring
chamber
●● MCERTS heating air

exhaust

diluting air heating diluting air fan


injector
air fan

Measuring range Rack frame with control unit


dust in operation 0 ... 15 (max. 100) mg/m³ dimensions 600 × 1750 × 550 mm
higher on request (W × H × D)
exhaust gas > 100 % relative humidity, max. space 1100 × 1750 × 1100 mm
moisture limit 30g/m3 H2O as aerosol requirements (W × H × D)
value
Probe unit weight approx. 90 kg
dimensions 600 × 1050 × 1500 mm (W × H × D), protection class IP55
including probe
length 1000 mm
weight approx. 40 kg ambient -20 ... 50°C
temperature
probe material stainless steel, Hastelloy as option power supply 230/400 V, 50 Hz, 3x16 A, 3 L, N, PE
others optional
protection class IP65 Connections on control unit
ambient -20 ... 50°C current outputs 4x 4 ... 20 mA, galvanically isolated
temperature with common ground
measuring gas max. 280°C (higher on request) load max. 1 kOhm
temperature
measuring air flow 8–10 m³/h digital contacts 6x max. 35 V 0.4 A
rate
flange DN 80 PN 6 special version digital input optional via switching contact
tube Ø100 mm to external­ly change between
measuring/purging
terminal contacts max. 2.5 mm²

8
F- 904-20

Extractive beta gauge


particulate monitor
Dust monitor especially for wet
flues - emission temperature under
dew point - and for the monitoring
of blast furnace gas

Features
●● 14C emitter and detector (Geiger-Müller
●● Automatic zero correction counter)
●● Pre-calibrated, unaffected by particle size, ●● Sample gas cooler
colour or moisture ●● PLC control, also for calculating the concen-
●● Sample gas flow regulated at 1 - 3 m3/h tration from the dust content
●● Isokinetic sampling
●● Optional dilution sample probe for high dust Options
concentrations or after wet scrubbers Measuring principle
●● Dust collection support function for heavy ●● Special design F-904-20/BFG for measure-
metal analyses Determination of the dust concentration by ment of the dust concentration in toxic and
●● Special model with measuring chamber measuring the absorption of beta rays emitted explosive blast-furnace or converter gas with
purging and CO-TLV monitoring during dust by a radioactive emitter by particles collected shut-off valves for the sample gas during
monitoring of blast furnace gas from an exhaust gas flow. filter transport and with purge gas (usually
nitrogen) for line back purging. Additional
Applications System components gas sensors need to be installed in the de-
ployment area of the device which close all
●● Coal and oil-fired power stations ●● Heated sample probe (material 1.4571 or connections to the process gas and trigger
●● Waste incineration plants (municipal waste, titanium), with or without dilution an alarm.
industrial waste and hazardous waste) ●● Heated sample line in 1.4571 ●● Filter tape printer and protective sheet for
●● Sewage sludge incineration plants ●● Filter tape in gas-tight filter holder supporting heavy metal analyses.
●● Emission dust measurement after wet scrub-
bers or in very wet exhaust gases sample probe, nozzle
●● Heavy metal analysis pressurized air
●● Measurement of very low dust concentra- PLC
tape-filter printer
tions in emissions (option) 4–20 mA
●● Emission dust measurement in inaccessible STATI
cover foil counter tube
flues with small diameter (option)
C-14 source
●● Dust concentration measurements in pro- total flow
vacuum pump
cess applications filter housing with bypass total flow dilution
controller Venturi gas
nozzle Venturi
Approvals supply reel nozzle

●● Suitability-tested by the RW TÜV, filter advance


stepping motor
take-up reel sample cooler
with automatic
test reports 3.5.2/209/88-338529 and drain
252/740/94577412
dilution gas control valve

measurements dust concentration detection limit <0.1 mg/Nm3


measuring ranges 0–1 ... 0–1000 mg/Nm3 reference point <1% of measuring range/month
drift
measuring beta ray absorption zero point drift automatic zero point correction
principle
flue gas 0–250°C, supply voltage 115 / 230 VAC, 50 / 60 Hz
temperature optional up to 500°C measuring device: 1300 VA
sample probe: 1700 VA
flue gas pressure -100 up to +200 hPa sample line: 120 VA/m
duct diameter >0.5 m separate cooling unit or cabinet
heating (option): 100VA
ambient 0 up to +50°C, cooler optional
temperature
protection IP43 (with filter blower),
upgradable to IP54
measuring outputs 2× 0/4–20 mA / 500 Ohm dimensions 1600 × 800 × 800 mm
(h × w × d)
digital outputs 11 relay outputs, weight 250 kg
permissible load 24 V / 25 VA
digital inputs 2 potential free inputs purge air supply pressurized air 6–8 bar
Error limit <5% of measuring range option dust monitoring of blast furnace
gas

9
D-FW 230 231 240/Ex

Filter monitor
Triboelectric filter monitor for
­efficiency monitoring after filter
plants and for continuous dust
measuring in dry emissions

Features Measuring principle System versions

●● Compact and rugged design The filter monitor uses the triboelectric effect D-FW 231 measuring probe
●● Good price/performance ratio to determine dust loads in flowing gases. The
●● Ideal for monitoring bag filters electrical charge which the dust particles expe- ●● With complete electronics in the probe
●● Minimal maintenance required rience due to friction is picked up by a probe ●● Probe rod length 1000 mm
●● Early detection of filter malfunctions protruding into the dust channel and converted ●● Fitted via 1“(G1) thread
●● Savings in cost, as no preventative filter ex- into a measuring signal by electronics. The
change is necessary. measuring signal is proportional to the dust D-FW 230 filter monitor
concentration and is calibratable at a constant
Applications gas speed. ●● D-FW 231 measuring probe
●● Probe rod length 1000 mm
●● Power stations ●● D-FW 230-B control unit with digital display
●● Bag filter plants of all types 115/230V 50/60 Hz.
●● Dust extraction plants in the production System components
industry
●● Waste incineration plants
●● Crematoriums
✖ Not suitable for use directly behind electro­
probe control unit
static precipitators.

Approvals

●● Suitability-tested by the TÜV Hamburg,


test report 98CU026

Options

●● Measuring gas temperature up to 500°C ●● Various mounting options (flange, connec-


●● Ex version D-FW 240/Ex tion piece)
●● Weather protection cover ●● Probe rod lengths 80, 250, 700, 1000 mm

measurements dust mass flow digital inputs* 2 potential free inputs


measuring ranges 0–100% accuracy <2% of measuring range
(flue gas velocity >5 m/s)
measuring tribo electric detection limit <2% of measuring range/month
principle
flue gas above dew point up to 200°C, reference point <0.3% of measuring range/month
temperature optional up to 500°C, drift
flue gas humidity <80%
flue gas pressure -500 up to +500 hPa zero point drift <0.3% of measuring range/month
duct diameter 0.3–4 m supply voltage 24 VDC, 5 VA
115 / 230 VAC, 50 / 60 Hz, 10 VA*
ambient -20 up to +50°C dimensions probe: 180 × 80 × (270 + probe
temperature (h × w × d) length) mm
probe length 80, 250, 400, 700 mm
protection IP65 weight probe: max. 4.5 kg
control unit: 3 kg
measuring outputs 0/4–20 mA / 500 Ohm
digital outputs* 1 relay output, remarks *D-FW 230 only
permissible load 250 V / 100 VA

10
D-RX 250

Combined
probe ­sensor
Single rod measurement probe for
simultaneous measurement of
- Dust concentration [mg/Nm³]
- Volume flow [Nm³/h]
- Temperature [°C]
- Absolute pressure [hPa]

Features Measuring principle

●● Only one probe / installation opening in the ●● The tribo probe measures the electric charge ●● The temperature is measured directly in
exhaust gas channel of the incident particles. the centre of the flue gas flow in a separate
●● Compact design, no moving parts, no con- ●● The measurement of the volume flow is chamber within the probe with a tempera-
sumable parts based on the mechanical action principle. ture sensor.
●● Continuous conversion to normalised dust The probe has two separate chambers, be- ●● Dust concentration is calculated from
concentration in mg/Nm3 and to normalised tween which a differential pressure builds up the ­triboelectric measuring signal and the
volume flow in Nm3/h under flow. volume flow. The raw data that are also
●● LCD display in mg/Nm3, Nm3/h,°C and hPa, ●● The absolute pressure in the flue gas is measured for gas temperature and absolute
one analogue output for each measurement measured by a pressure transmitter in one pressure are used to calculate the standard
­value chamber of the probe dust concentration and the standard volume
●● Parameterization at the control unit without flow (wet).
the need of a PC or other tools
●● Remote connection of control and evalu-
System components
ation unit via two-wire bus interface up to probe transmitter differential control and
pressure evaluation unit
1000 m. transducer

Applications

●● For measurements in accordance with TI Air


(Technical Instructions for Maintaining Air
­Purity), 13., 17. and 27. BImSchV
✖ Not suitable for use behind electro­static pre-
cipitators. Please consult us
max. 1000 m
Approvals
●● Suitability-tested by the TÜV Cologne, Options
test report 936/800006/A ●● Automatic cyclic probe back purging for
●● MCERTS ●● Weather protection cover high dust concentrations
●● Switch-over cock for back purging / zero ●● Hastelloy probes for corrosive gases
point control ●● Purge air connection at flange
measurements dust concentration, volume flow, detection limit <2% of measuring range
absolute pressure, temperature
measuring ranges 0–10 ... 0–500 mg/Nm³ reference point <1% of measuring range/month
0–9,999,999 Nm³/h 1) drift
0–200°C, optional 0–350°C
800–1,300 hPa
measuring dust: tribo electric zero point drift <1% of measuring range/month
principle volume flow: differential pressure
flue gas above dew point up to 200°C, supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA
temperature optional up to 350°C,
flue gas humidity <80%
flue gas pressure -200 up to 200 hPa dimensions probes: 180 × 180 × (340 + probe
(h × w × d) length) mm
probe length 250, 400, 700, 1000 mm
duct diameter 0.3–5 m weight probe 9.5 kg
electronics 22 kg
ambient -20 up to +50°C probe back purge air supply 3 bar
temperature purging (option)
protection IP65 insulator purging continuous purge air supply
(option) approx. 2 m3/h
measuring outputs 4x 0/4–20 mA / 500 Ohm,
Modbus RTU (RS485)
digital outputs 7 relay outputs, permissible load
48 V / 0.5 A
digital inputs 6 potential free inputs remarks 1)
f lue gas velocity >5 m/s
concentration after gravimetric
accuracy <2% of measuring range calibration

11
D-RC 120

Automatic sampling
 combination probe with Pitot tube and thermocouple


device for gravimetric filter head device

dust measurements
notebook
drying tower
external
sensor unit pump

System components control unit

●● D-RC 120 MD, consisting of control unit,


Features pump, drying tower, external sensor unit,
Windows software and accessories
●● Portable system ●● D-RC 120 FD filter head device, suitable for
●● Easy handling plane or tubular filters
●● Automatic isokinetic control ●● D-RC 120 P combination probe, heatable Option
●● Suitable for in- and out-stack sampling incl. gooseneck with nozzles
●● Highest measuring accuracy ●● Filter head device heater for out-stack
●● Available in stainless steel and titanium sampling
●● Compliant to EN 13284-1, 
VDI 2066, EN ISO
9096 and US-EPA Method 5 Technical data
Applications measuring principle gravimetric analysis
measuring result dust concentration
●● Calibration of dust monitors
●● Control measurements sampling In-stack, out-stack
●● Measurements at filter plants measuring range dust concentration: 0.1 ... 2000 mg/m3
differential pressure: 0.01 ... 10 hPa
Description
absolute pressure: 400 ... 1300 hPa
The D-RC 120 extracts isokinetically a partial gas temperature: 0 ... 500 °C
stream from the measuring gas duct whereas
the extraction is controlled fully automatically. Sample volumetric flow rate: 0.5 ... 4 m3/h
The device can be conveniently operated via Sample Gas
Windows software. The partial gas stream is
- temperature 0 ... 500 °C
sucked through a filter in which the contained
dust is deposited. - velocity 2 ... 39 m/s
- pressure -200 ... +20 hPa
The dust concentration is determined by weigh-
ing the filter before and after the extraction. - relative humidity 0 ... 95 % relative humidity, optional measurement
in saturated gas below the dew point
In parallel to the gas sampling, the measure-
ments of the dust monitor under test can be Probe
recorded and averaged. - length 1000 ... 3000 mm, others on request
- diameter 70 mm, quick release mounting for 3“ port
- weight 1.5 kg + 5.4 kg / m
- probe material stainless steel, optional titanium
Control unit
- power supply 230 VAC, 50/60 Hz, optional 115 VAC, 50/60 Hz
- ambient temperature -10 ... 60 °C
- protection IP 33
- electrical interfaces 1x 12 V output for audible signal
1x 4 ... 20 mA input, e.g. for AMS
1x RS 485 with USB converter
- operation operating software, requires netbook/notebook
(not scope of delivery) with Windows 7 or
Windows 8
- dimensions (h x w x d) approx. 350 x 280 x 250 mm
- weight approx. 8.5 kg

12
HM- 1400 TRX

Total mercury analyser


Measuring device for fully-automat-
ic and continuous mercury analysis
in smoke gas (without wet chemis-
try)

Features Measuring principle System components

●● Maintenance-free (6 months) dry reactor In the HM 1400 TRX total ●●sampling probe
●● High operational safety mercury analyser the sam- ●●sampling line
●● Easy maintenance ple gas is converted into ●●measuring device.
●● Low cross sensitivities mercury vapour by a com-
●● Easily legible LC display bination of thermal and dry Options
●● Three month maintenance interval chemical treatment. This is
then continuously measured ●●Larger measuring range
Applications in a photometer. The probe with dilution device
gas flow is measured after a gas cooler at 2°C. ●● Side-mounted cooling device
●● Waste incinerations (municipal waste, indus- The concentration is calculated and displayed as ●● Integrated system to generate reference gas
trial waste, hospital waste) „dry flue gas“. ●● Heated sample pipe 0.6 m, 1.0 m, 1.5 m;
●● Sewage sludge incineration 600 VA, 800 VA, 1200 VA.
●● Hazardous waste incineration
●● Steel plants with scrap metal preparation
●● Contaminated soil burning plants
●● Crematoriums
●● Mercury mines and refineries
●● Fluorescent light bulb recycling plants heated
sample probe
Approvals
pump
●● Suitability-tested by the TÜV Hamburg, thermocatalytic
reactor Hg-photometer
test report GMT007/8000632287 from zero gas
30.06.11 filter liquid watchdog
●● Approved and certified acc. to EN 15267-3 calibration reactor

●● MCERTS gas/liquid separator

option

stack

reference condensate
standard

measurements total mercury digital outputs 4 relay outputs,


permissible load 250 V, 100 VA
measuring ranges 0–45, 0–75, ... 0–500 µg/Nm³ digital inputs 1 potential free outputs
measuring UV-absorption detection limit <0.1 µg/Nm³
principle
flue gas 0–250°C reference point <2% ZRE
temperature drift
flue gas pressure -50 up to +50 hPa zero point drift <0.5% ZRE
automatic zero correction
duct diameter >0.5 m supply voltage 230/400 VAC, 50 Hz, 3x L, N, PE
instrument: 1200 VA,
ambient +5 up to +30°C sample probe: 650 VA,
temperature sample line: 100 VA/m
heated sample pipe:
600 VA, 800 VA, 1200 VA
protection IP40 (IP54) dimensions cabinet
(h × w × d) 1700 × 800 × 500 mm
measuring outputs 2× 0/4–20 mA/500 Ohm weight 220 kg
relative expanded 5.5% CR purge air supply pressurized air 6–8 bar (for
uncertainty reference gas generator only)

13
F- 701-20

Beta gauge particulate


monitor
A measuring device for the con-
tinuous monitoring of the smallest
­concentration of particles in the
­ambient air (fine dust)

Features Measuring ­principle


●● C-14 method, no measurable decrease in The measuring principle of the F-701-20 ambi-
­activity ent dust monitor is based on the absorption of
●● Lowest radioactivity of all beta gauges, usa- the beta rays (electrons) emitted by a radioac- Options
ble without licence, or disclosure tive emitter through particles collected from an
●● Automatic zero correction ambient air flow. In the F-701-20 the count ­rate Sample inlets:
●● Pre-calibrated measuring device of the unloaded filter tape is measured before ●● PM-2.5 according to EN
●● Mass-flow controlled sample flow 1m3/h each collecting cycle, then dust is collected on 14907
●● Extraction of a constant sample flow, irre- this precise filter spot over a pre-defined ­period, ●● PM-10 according to EN 12341
spective of the ambient temperature and finally the count rate of the loaded filter ●● Total dust according to VDI 2463
and ambient pressure tape is measured. The difference between the ●● PM-2.5 according to US-EPA
●● Repeated collection on the same spot, col- two count rates is evaluated in the device and ●● PM-10 according to US-EPA
lected particles available for compositional displayed as dust concentration in µg/m3.
analysis (heavy metals)
●● RS-232 interface and 2 analogue outputs,
status signals

Applications Sample Probe Heater


(optional) Sample Inlet
Measurement of T
●● Ambient air measuring systems for monitor- and rel. Humidity
ing fine dust (optional)
●● Mobile air pollution monitoring
●● Dust measurement in health and safety ap- Data processing,
Options Control
plications
interface
●● Interior dust measurements
●● Measurement and collection of dust par- GM Counter Tube
ticles for compositional analysis (heavy
C-14 Source
metals) Cover Foil
Filter Adapter
(optional)
●● Long-term background studies in ambient
Filter Tape Printer
dust concentration (optional)
●● Dust measurement and collection at prob- measured strip chart Supply Reel
value recorder Stepping Motor for
lem sites and repositories printer Filter Transport
●● Dust measurement for secondary emission vacuum
Take-up Reel pump
of repositories (e.g. coal). sample
●● Dust measurement in supply air and exhaust volume
flow Filter
ducts Read/ Write Data
from/ to Instrument Flow-Meter

Approvals Bypass-Valve

●● Suitability-tested by the TÜV Munich,


test report 720349
●● Suitability-tested by the TÜV Cologne, measurements dust concentration accuracy fulfills the quality requirements
test report 936/21220478/A acc. to 2008/50/EU
measuring ranges 0–100 µg/m³ ... 0–10 mg/m3 detection limit <1 µg/m³
measuring beta-ray absorption reference point <1% of measuring range/month
principle drift
ambient device: 0 up to +40°C zero point drift automatic zero point correction
temperature sample inlet: -20 up to 50°C
protection IP30 supply voltage 230 VAC / 50 Hz, 110 V / 60 Hz,
400 VA
measuring outputs 2× 4–20 mA / 500 Ohm dimensions 320 × 450 × 500 mm,
(h × w × d) 19“-rack mount / desk unit
digital outputs 8 relay outputs, weight 31 kg
permissible load 24 V, 12 VA
digital inputs 3 potential free inputs probe tube length standard 2 m
0.5–3 m possible
digital interface RS 232

14
D-ISC 100 D-ESI 100

D-ISC 100
Universal operating and display
unit in stainless steel field hous-
ing for the new generation sensors
from DURAG, e.g.
D-FL 100, D-FL 220, D-R 220 or
D-R 320

Features Application Options

●● Easy set-up and automatic detection of up to The universal operating and display unit D-ISC ●● 4 slots for expansion modules:
eight connected sensors 100 allows the connection of up to eight meas- - Modbus RTU interface acc. to VDI4201-3
●● Uniform operation of various sensors uring devices as for instance dust and volume - 4 analogue outputs 0/4-20mA / 500 Ohm
●● Large LC Display for measured value display flow monitors. - 4 analogue inputs 0-20mA/100 Ohm
●● Comfortable operation and handling via The D-ISC 100 offers access via the built-in - 4 digital inputs
keypad panel, a connected PC or remote access via the - 4 relay outputs 48 V/0.5A
●● USB interface for local device operation intranet/internet and easy parameterization of
●● Remote support via intranet/ internet the connected DURAG devices. ●● Interface converters, e.g. for
●● Modular design, expansion slots and slot for The display allows direct view of the current - Profibus DP
external converter available measuring values. ●● Software modules
●● Easy update via SD memory card
Analogue output 0/4-20 mA / 500 Ohm Housing Stainless steel 304,
●● Power supply 24 VDC/2A for one directly RAL 5017
connected sensor Digital outputs 3 relay outputs 48 V /0.5 A Dimensions (h × w × d) 122× 330 × 220 mm
Digital input 1 digital input, operation Weight 5 kg
via potential-free contact
Ambient temperature -20 up to +50 °C, Protection rating IP65
-40 up to +60 °C optional
Service-Interface USB, TCP/IP Supply voltage 90–264 VAC, 48–62 Hz

D-ESI 100
Service- and Parameterization
­Software

Features

●● Easy set-up and automatic detection of the


connected sensors
●● Uniform parameterisation of various sensors
●● Remote support via Intranet/ Internet
●● Communication via USB, DURAG-Modbus or
Modbus TCP

Application Requirements

D-ESI 100 is a graphical interface for operation, ●● PC with Microsoft Windows® operating
parameterisation and management of the con- ­system 7 or 8
nected sensors. ●● USB interface
D-ESI 100 offers access to the parameters of the ●● Serial interface RS485
connected sensors via USB interface, the DURAG ●● Ethernet interface
Modbus interface or via Modbus TCP.

15
D-FL 100

Volume flow
measuring ­system
Measuring system to measure flow
rate in dry emissions with a probe
using the differential pressure prin-
ciple

Features Measuring principle System components

●● Measurement of gas velocity The D-FL 100 measuring system operates ac- ●● Mounting flange
●● Calculation of volume flow at standard con- cording to the differential pressure principle. ●● Flow probe
ditions The probe has two separate chambers, between ●● Counter-support
●● Adjustable parameters which the flow builds up a differential pressure. ●● Differential pressure transducer
●● Automatic back purging device (optional) Taking account of the other flow parameters ●● Cross-over cock
●● Versions with or without counter-support such as, e.g. absolute pressure and temperature, ●● Probe adapter
and for point measurement. the volume flow can be converted from opera- ●● Microprocessor evaluation unit D-FL100-20
●● Three month maintenance interval ting to standard conditions with the evaluation ●● Absolute pressure transducer
unit. ●● Temperature transducer
Applications
Models Options
●● Volume flow measurement at high temper-
atures ●● D-FL 100 probe assembly ●● Display and control unit D-ISC 100
●● Plants with large or small flue cross-sections with assembly of measuring transducer on ●● Service software D-ESI 100
●● Volume flow measurement at high pressure the probe (not for probe 3) ●● Weather protection covers
●● D-FL 100 hose assembly ●● Automatically controlled back purging de-
Approvals with the measuring transducer connection vice
via hose line ●● Special designs in other materials for appli-
●● Suitability-tested by the TÜV Cologne, cations with particularly aggressive exhaust
test report 936/21218492/A Probes gases or high gas temperatures
●● Approved and certified acc. to EN 15267-3 ●● dP-transducer in Ex-version
●● MCERTS ●● Probe 1: 0.4–2 m
●● Probe 2: up to 4 m
differential pressure transducer
●● Probe 3: up to 8 m
flow 4 ... 20 mA
evaluation
4 ... 20 mA unit
4 ... 20 mA
cross-over cock

absolute temperature
pressure transducer
transducer

flow probe

flow direction

measurements flue gas velocity, volume flow digital outputs 2 relay outputs,
permissible load 48 V / 0.5 A
measuring ranges 0–3000000 m3/h / 2–50 m/s accuracy <2% of measuring range
measuring differential pressure detection limit <3 m/s
principle
flue gas above dew point up to 450°C, reference point <0.5% of measuring range/month
temperature optional up to 850°C drift
flue gas pressure ±200 hPa, optional higher zero point drift <0.5% of measuring range
duct diameter 0.4–8 m supply voltage 90 / 264 VAC, 50–62 Hz, 100 VA
optional 18–32 VDC
ambient -20 up to +50°C dimensions probe: 380 × 160 × (300 + probe
temperature (h × w × d) length) mm
protection IP65, Ex optional weight 32 kg + 6,8 kg/m probe length
measuring outputs 0/4–20 mA / 500 Ohm, Modbus purge air supply 6–8 bar for back purging if
RTU, RS485, acc. to VDI 4201-3 necessary

16
D-FL 220

Volume flow
measuring system
Measuring system for ultra-sonic
measuring of flow and volume flow,
especially for wet and aggressive
smoke emissions (waste incinera-
tion)

Features Measuring principle Options

●● In-situ measuring method The D-FL 220 measuring system works accord- ●● Temperature transducer
●● Measurement possible below dew point and ing to the acoustic transit time differential ●● Absolute pressure transducer
for high dust concentrations method as well. The flow velocity resp. volume ●● Universal display and control unit D-ISC 100
●● Continuous measurement of normal volume flow of the waste gas is precisely calculated ●● D-ESI 100 Service- and Parameterization
flow and gas velocity from the transit time difference dependent on Software
●● Automatic zero point and reference point the direction.
control
●● New design, digital signal processing System components
●● D-FL 200 compatible follow-up model
●● Remote access possible, digital interface ac- ●● 2 Measuring heads
cording to VDI 4201-3 ●● 2 Purge flanges (material 1.4571)
●● Operation with or without control unit ●● 2 Mounting flanges (Mat. 1.4571, FRP)
●● Very low maintenance ●● Purge air unit for cleaning and cooling the
sensors
Applications ●● Terminal Box for power supply of the sensors

●● Volume flow measuring at low speeds duct measuring


●● Plants with damp and/or aggressive exhaust head
gas, e.g. in waste incineration plants.
●● Volume flow measurement at high dust
content
purge air
Approvals

●● Suitability-tested by the TÜV Cologne,


test report 936/21218490/A
●● Approved and certified acc. to EN 15267-3
●● MCERTS

purge air

measurements flue gas velocity, volume flow 1), detection limit <0.3% of measuring range
temperature
measuring ranges 0–3,000,000 m3/h / 0–40 m/s reference point <0.3% of measuring range/month
0–400°C drift
measuring acoustic propagation delay zero point drift <0.2% of measuring range/month
principle
flue gas 0–300°C, optional higher supply voltage 24 VDC, 0.5 A
temperature
flue gas pressure -50 up to +20 hPa, optional higher dimensions standard measuring head:
(h × w × d) 190 Ø × 570 mm
duct diameter 0.5–13 m, temperature dependent weight 17 kg
ambient -20 up to +50°C remarks 1)
 ptional pressure and
o
temperature measuring head -40 up to 70°C temperature correction
protection IP65 purge air supply
measuring outputs 0/4–20 mA / 400 Ohm, purge air quantity approx. 80 m3/h
Modbus RTU bi-directional
digital outputs 2 relay outputs, supply voltage 115 / 230 V, 50 / 60 Hz,
permissible load 48 V / 0.5 A 0.37 / 0.43 kW
digital inputs none dimensions 350 × 550 × 500 mm
weight 12 kg
accuracy <2% protection IP55

17
D-EMS 2000

Data acquisition and Data acquisition, evaluation and Main Features


­reporting according to:
handling system ●● Windows based DAHS with modern de-
signed software running on a standard pc
●● German regulations for all plants requiring ●● User friendly, menu-driven software avail-
family of modular DAHS systems for approval able in 19 languages
management of environmental and ●● European Industrial Emissions Directive (IED) ●● Data communication unit with internal data
2010/75/EC storage system for up to 96 days for high
process data
●● US EPA 40 CFR Part 60 & 75 data availability
●● GHG Emission Monitoring (European-, UN- ●● Handling of up to 320 analogue/ 640 binary
FCCC-Guidelines, etc.) in- and outputs, resolution 1 second
D-EMS 2000 ●● Country-specific requirements ●● Interfaces for hardwired 0(4) to 20 mA and/
or bus communications TCP/ IP, OPC UA,
●● QAL 1 certified according to EN 15267 Approvals Modbus, PROFIBUS, Elan etc.
●● MCERTS certified ●● Encrypted database on 2 Hard Disk Drive/
●● Suitability-tested by TÜV in accordance with Solid State Drive as Raid-1-Array
D-EMS 2000 CS German TA-Luft, 1., 2.,13., 17., 27. 30. and ●● Menu leaded screens for representation of
31.BImSchV as well as the European Direc- current, prognostic and historic measured
●● QAL 1 certified according to EN 15267 tives 2010/75/EC , 2000/76/EC and 2001/80/ data in bar graph/ chart form
●● MCERTS certified EC considering EN 14181 ●● Free configurable screen masks, time dia-
●● Approved and certified acc. to EN 15267-2 grams and reports on customer request
D-DAS 2010 ●● MCERTS certified ●● Automatic alarm and information system
with comment functionality
●● Cost effective system Management for: ●● Communication with customer data network
●● MCERTS certified incl. interface to MS-Excel
●● Emission data ●● Automatic data transfer to authority via
D-DAS 2000 ●● Water data standard remote communication if required
●● Greenhouse gas (GHG) data ●● Providing of relevant data in the internet/
●● Cost effective system ●● Ambient Air data Intranet for person in charge, authority or
●● Excellent cost/performance ●● Meteorological data public
ratio ●● Process data ●● Remote Service Interface for cost effective
●● etc. service and support
4- OD fib
M o PC
20 B us
Pr O AN

m US
A
EL

R
Me ing
>3 mor
2d y
TC

ay
P

R s
/I

Me ing
P

>3 mor
4- OD fib
M ro PC N
20 B us

2d y
P O A

m US

ay
A

s
EL
Pe (A

..8
D
rs ut

-M

1.
on h

S
50
in rit

0
K
C y)

E
h
o

ar

D C
-E li
g
e

M en
S t
20
00
w
w

D C
-E li
w

M en
S t

R
Me ing
20
00

>5 mor
Ind yea y
iv rs
v idu
Proalue al -
D C
-E li

toc s
M en
S t

ols
20
00

Sy
st
Ra em
id
1
Sy -
st EM
em
D

Ba
c
W 2

on kup
or 0

HD ext
ks 0
S

/SS .
ta 0

D
ti

TC
on

P
/I
P
D P
C S
F7
G

18
D-EMS 2000 CS

Data acquisition and


handling system
Price effective compact system for
small and middle sized plants

4- OD s, E
20 B la
M bu C
Pr
A

ofi O

m S n,
u

A
th

U
or

P
it
y

D C
-E li
R

M en
6 Ying M

S t
20
w

00
ea e

w
+ rs mo
Features

w
30 ProtInt, Dry

D C
-E li
M en
Da oco ay

S t
Ba

20
cku y
+ 1s 1mls

00
o p
HD n
●● Compact system, no additional evaluation /SS s in

D C
D
D-

-E li
M en
EM

S t
PC required

20
S2

00
●● Modern flash memory technology instead of 00
0C
S
hard disks
●● Independently operating module for acqui-
sition, long-term storage, calculation and
visualisation of environmental and process

D P
C S

TC
F7
data

P
/I
P
●● Instrument for monitoring officially pre- Main features
scribed limit values with automatic logging
●● Continuous monitoring of 1 to 12 compo- ●● Windows based and certified D-EMS 2000 software
nents connected via bus communication or ●● All modules from the D-EMS 2000 system are usable
hard wired ●● Excellent cost/performance ratio

Options

Three device types are available:


●● 19“ 3HU rack with monitor/ keyboard/
mouse
●● 19“ 1HU unit with slide-in keyboard and
­retractable monitor
●● Desktop version with monitor/keyboard/
mouse

Applications

●● Emissions evaluation computer for small to


medium-sized installations in all types of
plants and industries

Computer Intel based Dual core PC with Windows 7 & 8, 2 GB Ram and > 100 GB SSD
inputs / outputs up to 3 cards:
combined card: 4 AI / 8 DI / 2 AO / 4 DO
input card: 8 AI / 15 DI
output card: 8 AO
output card: 16 DO
bus system connections Modbus RTU / TCP, PROFIBUS, Elan, OPC UA
analogue-/digital inputs: 12/24
analogue-/digital outputs: 12/24
interfaces 1x VGA, 2x USB, 1x RJ 45, 3x serial (RS232 or RS485), BNC for DCF 77- radio clock
ambient temperature 5 up to +40°C
protection IP 20
operating voltage 115/230 VAC / 50/60 Hz / 100 VA

19
DURAG Sales and Marketing DURAG Niederlassung Nord DURAG Niederlassung West DURAG Niederlassung Süd
GmbH & Co. KG Kollaustraße 105 An der Pönt 53a Weidenweg 16
Kollaustraße 105 22453 Hamburg, Germany 40885 Ratingen, Germany 73087 Bad Boll, Germany
22453 Hamburg, Germany Tel. +49 40 55 42 18-0 Tel. +49 2102 74 00-0 Tel. +49 7164 912 25-0
Tel. +49 40 55 42 18-0 Fax +49 40 58 41 54 Fax +49 2102 74 00 28 Fax +49 7164 912 25-50
Fax +49 40 58 41 54 E-Mail: durag-nord@durag.de E-Mail: durag-west@durag.de E-Mail: durag-sued@durag.de
E-Mail: info@durag.de
DURAG Niederlassung Ost
Halsbrücker Straße 34
09599 Freiberg, Germany
Tel. +49 3731 30 04-0
Fax +49 3731 30 04-22
E-Mail: durag-ost@durag.de

DURAG GmbH DURAG data systems GmbH DURAG process & systems DURAG Siena do Brasil Ltda
Kollaustraße 105 Kollaustraße 105, ­technology gmbh Rua Vinte e Dois de Agosto, 66
22453 Hamburg, Germany 22453 Hamburg, Germany Kollaustraße 105 Diadema - SP
Tel. +49 40 55 42 18-0 Tel. +49 40 55 42 18-3000 22453 Hamburg, Germany 09941-530 Brazil
Fax +49 40 58 41 54 Fax +49 40 55 42 18-3099 Tel. +49 40 55 42 18-0 Tel. +55 11 4071-5050 r.28
E-Mail: info@durag.de E-Mail: info@durag-data.de Fax +49 40 58 41 54 Fax +55 11 4077-1718
E-Mail: info@durag-process.de E-Mail: info@duragsiena.com.br

Hegwein GmbH SMITSVONK Holland B.V. A Brand of


Am Boschwerk 7 P.O. Box 180, 2700 AD Zoetermeer DURAG GmbH
70469 Stuttgart Goudstraat 6, 2718 RC Zoetermeer Kollaustraße 105
Germany Netherlands 22453 Hamburg, Germany
Tel. +49 711 135 788-0 Tel. +31 79 361 35 33 Tel. +49 40 55 42 18-0
Fax +49 711 135 788-5 Fax +31 79 361 13 78 Fax +49 40 58 41 54
E-Mail: info@hegwein.de E-Mail: sales@smitsvonk.nl E-Mail: verewa@durag.de

DURAG Brazil DURAG France S.a.r.l. DURAG, Inc., USA DURAG India Instrumentation
DURAG Siena do Brasil Ltda Parc GIP Charles de Gaulle 1355 Mendota Heights Road Private Limited
Rua Vinte e Dois de Agosto, 66 49, rue Léonard de Vinci, BP 70166 Suite 200 #27/30, 2nd Main Road
Diadema - SP 95691 Goussainville CEDEX, Mendota Heights Industrial Town, Rajajinagar
09941-530 Brazil France MN 55120, USA Bengaluru 560 044, India
Tel. +55 11 4071-5050 r.28 Tel. +33 1 301 811 80 Tel. +1 651 451-1710 Tel. +91 80 2314 5626 / 4215 1191
Fax +55 11 4077-1718 Fax +33 1 393 383 60 Fax +1 651 457-7684 Fax +91 80 2314 5627
E-Mail: info@duragsiena.com.br E-Mail: info@durag-france.fr E-Mail: durag@durag.com E-Mail: info@duragindia.com
©DURAG GROUP 08/2014 · Subject to change without notice

DURAG Instrumentation DURAG Italia S.r.l. DURAG Japan Office DURAG Korea Office
(Shanghai) Co., Ltd. Via Carlo Panseri, 118 c/o TMS Planning Inc. RM #1131, Manhattan Building,
Room 706, Dibao Plaza, No. 3998 CIM uffici, P. secondo 291-2 Umena, Mishima-shi, 36-2, Yeouido-Dong,
Hongxin Rd., Minhang District, 28100 Novara Shizuoka-ken, Yeongdeungpo-Gu, Seoul,
Shanghai, 201103 PR China Italy 411-0816 Japan Korea
Tel. +86 21 60732979-206 Tel. +39 0321 679569 Tel. +81 55 977 3994 Tel. +82 2 761 8970
Fax +86 21 60732980 Fax +39 0321 474165 Fax +81 55 977 3994 Fax +82 2 761 8971
E-Mail: info@durag-cn.com E-Mail: info@durag.it E-Mail: info@durag.jp E-Mail: info@durag-group.co.kr

DURAG RUSS OOO DURAG UK GmbH


Andropova avenue 18/6, Lullington House, Ashby Road
Office 2-03 Burton-on-Trent, Staffordshire,
115432 Moscow E15 0YZ
Russia Great Britain
Tel. +7 499 4180090 Tel. +44 1283 553 481

www.durag.de
Fax +7 499 4180091 Fax +44 1785 760 014
E-Mail: info@durag-group.ru E-Mail: durag.uk@durag.de

smart solutions for combustion and environment