Professional Documents
Culture Documents
2 Service LOX
3 Location IN VESSEL
4 Equipment System DCS
5 Line number P&ID NA A10239.10
GENERAL
6 Hazardous area class Ignition temp ident number Z one - 2 T6
7 Ambient temperature Min Max -45° C 65° C
8
9 NACE Requirement IBR Certification NA NA
10
PIPE 11 Line size Line schedule 3/4" 40S
LINE 12 Pipe material class Pipe material Pipe insulation SA312 TP304
13 Fluid name Fluid state LOX GAS
14 Corrosive Erosive Toxic Build-up tendency
15 PROCESS DESIGN CONDITIONS Units Minimum Maximum
16 Design pressure BAR(g) 14.4
PROCESS 17 Design temperature °C -45 65
CONDITIONS 18
19
OPERATING CONDITIONS Units Minimum Normal Maximum
20
Pressure BAR(g) 13.4
21
Temperature °C -20 15
22
Density kg/m3 422
23 Body/Flange type STD DUAL COMPARTMENT 316 SS 52 Seal type NA
24 Process conn size Rtg 1/2" 53 Process conn size Rtg
25 Process conn typ Style NPT 316 L SST 54 Process conn typ Style
26 Vent/Drain location BOTTOM 55 Diaphragm extension lg
27 Vent/Drain size Style 8 MM SS 316 SS 56 Flush conn qty Size
TRANSMITTER 28 Mounting type 2" PIPE, ANGLE BRACKET 57 Instr conn nom size
BODY 29 Body/Flange material AL / THREAD TYPE 58 CapillaryFitting dia Length
30 Vent/Drain material 316 SST DIAPHRAGM 59 Diaphragm material
31 Bolting material 316 SST SEAL 60 Capillary-armor matl
32 Gasket/O ring material GLASS FILLED PTFE 61 Bolting material
33 Mounting kit material 316 SST 62 Upper housing material
34 63 Lower/Flange material
35 Detector type CAPCITANCE TYPE 64 Gasket/O ring
36 Min press span Max -1 55 bar 65 Fill fluid material
SENSING
37 Diaphragm/Wetted matl DIAPHRAGAM WITH FILL FLUID SS316 66
ELEMENT 38 Fill fluid material 0.04%
SILICONE 67 Pressure accuracy
39 68 Pressure LRL URL -1.01bar 55.16 bar
40 Output signal type 4 To 20 mA PERFORMANCE 69 Zero supp/Elev Required
41 Enclosure type number 4 X IP 68 70 Fill fluid sp gr AT -14.7
42 Digital communication HART 71 zero span adjustment Required
43 Signal power source 24V DC 72 M R No.
PURCHASE
44 Integral indicator style LCD METER 73 Item No.
45 Signal termination type MANUFACTURER STD Notes:
TRANSMITTER
46 Cert/Approval type CCOE ONE 1/2" NPT 316SS PLUG SHALL BE SUPPLIED BY VENDOR.
47 Enclosure material Aluminium Epoxy Coated FOR BLINDING UNUSED CABLE ENTRY
48 Write Protection AVAILABLE
Model number
49 Elect. conn size Type 1/2" NPTF
3051S
50 Instrument Range Min -1 bar
51 Instrument Range Max 55 bar
74 Tag No. Measurement/Test Input LRV Input URV Units Action Output LRV Output URV Units
75 Pressure - output signal
76 --- Pressure scale 0 35 bar
77
78 Instrument type Manufacturer
79 Pressure Transmitter Emerson
80
Confidential Document. This Document contains confidential information proprietary to RIL.
Proj No. DEC/PV Proj Name
Neither whole nor part of this document may be reproduced, disclosed without prior permission of the copyright owner. All rights are reserved.
(2) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory
configured, add option code HR7.
(3) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(4) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(5) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(6) “Assemble-to” items are specified separately and require a completed model number.
(8) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges,
assemble-to manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish
certification (Q16 code), and remote seal system report (QZ code).
(10) Only available with HART 4-20 mA output (output code A).
(12) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(13) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
(14) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
(16) Only available with Standard 3051. See specification section for more information.
(17) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option.
(18) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(19) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
Product Data Sheet
00813-0100-4001, Rev MA
May 2012 Rosemount 3051
4.85
(123)
4.1
(105)
6.25
(159)
6.15
[156]
2.81
[71]
6.15
[156]
3.49
[89]
4.78