You are on page 1of 7

Checking forces in critical members of Truss as per IS

Case of symmetrical axially loaded strut / rafter / tie members


other than single angle loaded through one leg

Input in cells with grey colour Use password: 123 to un

Checking compression as

Effective Area of
Sl No. Member Section length (KL r min cross- fy fcc λ
) section

(metre) (mm) (mm2) (N/mm2) (N/mm2)


1 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
2 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
3 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
4 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
5 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
6 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
7 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
8 Rafter SHS 92x92x4.5 1.68 18.66 1130 250 243.521 1.013
rs of Truss as per IS 800 : 2007

Use password: 123 to unprotect sheet

Checking compression as per 7.1.2 of IS 800 : 2007


Design
Imperfection
Stress Design Factored design tensile Factored design
factor ( α )
φ reduction fcd compressive compression in strength tension in
[see the table
factor ( χ ) strength member due to member
below]
yielding

(N/mm2) ( kN ) ( kN ) ( kN ) ( kN )
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
0.21 1.098 0.657 149.32 168.73 125 256.82 180
Adequacy in Adequacy
compression in tension

Safe Safe
Safe Safe
Safe Safe
Safe Safe
Safe Safe
Safe Safe
Safe Safe
Safe Safe
Checking forces in critical members of

Case of single angle loaded through one leg with weld or


minimum 2 bolts (connection at the end fixed)

Input in cells with grey colour

Width of legs of angle

Radius of
Centre to Area of
Thickness gyration
Sl No. Member Section of Angle centre b1 b2 cross-
of leg (t) about minor
length (L ) section
axis (rvv)

(metre) (mm) (mm) (mm) (mm) (mm2)

1 Strut 80x80x10 2 80 80 10 15.5 1500


2 Strut 80x80x10 2 80 80 10 15.5 1500
3 Strut 80x80x10 2 80 80 10 15.5 1500
4 Strut 80x80x10 2 80 80 10 15.5 1500
5 Strut 80x80x10 2 80 80 10 15.5 1500
6 Strut 80x80x10 2 80 80 10 15.5 1500
7 Strut 80x80x10 2 80 80 10 15.5 1500
8 Strut 80x80x10 2 80 80 10 15.5 1500
tical members of Truss as per IS 800 : 2007

Use password: 123 to unprotect sheet

Stress Design
Yield stress
fy λvv λφ λe φ reduction fcd compressive
ratio (ε)
factor ( χ ) strength

(N/mm2) (N/mm2) ( kN )

250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54


250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
250 1 1.452 0.09 1.049 1.258 0.512 116.36 174.54
Design
Factored design tensile Factored design
Adequacy in Adequacy
compression in strength tension in
compression in tension
member due to member
yielding

( kN ) ( kN ) ( kN )

170 340.91 200 Safe Safe


170 340.91 200 Safe Safe
170 340.91 200 Safe Safe
170 340.91 200 Safe Safe
170 340.91 200 Safe Safe
170 340.91 200 Safe Safe
170 340.91 200 Safe Safe
170 340.91 200 Safe Safe

You might also like