You are on page 1of 8

Project Improvement of the 5th Industrial Intersection/Sharjah (Emirates Rd.

Structure Bridge S22_KA3-1

Stage* 1
Tendon Number 5
Location* web

SEQUENCE Tendon Reference


1 T1
2 T2
3 T3-5
4 T4
5 T31
TENDON reference T1 0 0
0 0 5000 10000 15000
TENDON sequence 1 0
0
Stressing at RIGHT END 225
0
Y Reference line - angular deviation* (deg) 0
2500

Y
-1
Z Reference line - angular deviation* (deg)
-1
-1
*In case of curved reference line -1
x,y,z : distance from the reference line to the center of the duct -1
the reference line must be continuous -1

2225
Coordinates (mm)
x y z
LEFT END 0 0 2500 1725

1000 0 2450

z
1225
2000 0 2390
3000 0 2355
725
4000 0 2330
4820 0 2325
225
5820 0 2225 0 5000 10000 15000
6820 0 1910
7820 0 1335
8820 0 745
9820 0 375
11020 0 225
12020 0 225
13020 0 225
14020 0 225
15020 0 225
16020 0 225
17020 0 225
18020 0 226
19355 0 225
20565 0 385
21565 0 755
22565 0 1350
23565 0 1915
24565 0 2225
25565 0 2325
26480 0 2330
27480 0 2355
28480 0 2395
29480 0 2450
30480 0 2500
TENDON reference T2 0 0
0 0 5000 10000 15000
TENDON sequence 2 0
0
Stressing at BOTH ENDS 225
0
Y Reference line - angular deviation* (deg) 0
3000

Y
-1
Z Reference line - angular deviation* (deg)
-1
-1
*In case of curved reference line -1
x,y,z : distance from the reference line to the center of the duct -1
the reference line must be continuous -1

2725
Coordinates (mm)
x y z 2225
LEFT END 0 0 3000
1000 0 2920 1725

z
2000 0 2700
1225
3000 0 2485
4000 0 2360 725

4820 0 2325
225
5820 0 2225 0 5000 10000 15000
6820 0 1915
7820 0 1345
8820 0 750
9820 0 380
11020 0 225
12020 0 225
13020 0 225
14020 0 225
15020 0 225
16020 0 225
17020 0 225
18020 0 225
19355 0 225
20565 0 380
21565 0 750
22565 0 1345
23565 0 1915
24565 0 2225
25565 0 2325
26480 0 2365
27480 0 2495
28480 0 2700
29480 0 2920
30480 0 3000
TENDON reference T3-5 0 0
0 0 5000 10000 15000
TENDON sequence 3 0
0
Stressing at BOTH ENDS 225
0
Y Reference line - angular deviation* (deg) 0
2500

Y
-1
Z Reference line - angular deviation* (deg)
-1
-1
*In case of curved reference line -1
x,y,z : distance from the reference line to the center of the duct -1
the reference line must be continuous -1

2225
Coordinates (mm)
x y z
LEFT END 0 0 2500 1725

1000 0 2450

z
1225
2000 0 2390
3000 0 2355
725
4000 0 2330
4820 0 2325
225
5820 0 2225 0 5000 10000 15000
6820 0 1915
7820 0 1345
8820 0 750
9820 0 380
11020 0 225
12020 0 225
13020 0 225
14020 0 225
15020 0 225
16020 0 225
17020 0 225
18020 0 225
19355 0 225
20565 0 380
21565 0 750
22565 0 1345
23565 0 1915
24565 0 2225
25565 0 2325
26480 0 2330
27480 0 2325
28480 0 2395
29480 0 2450
30480 0 2500
TENDON reference T4 0 0
0 0 5000 10000 15000
TENDON sequence 4 0
0
Stressing at BOTH ENDS 225
0
Y Reference line - angular deviation* (deg) 0
3000

Y
-1
Z Reference line - angular deviation* (deg)
-1
-1
*In case of curved reference line -1
x,y,z : distance from the reference line to the center of the duct -1
the reference line must be continuous -1

2725
Coordinates (mm)
x y z 2225
LEFT END 0 0 3000
1000 0 2920 1725

z
2000 0 2700
1225
3000 0 2485
4000 0 2360 725

4820 0 2325
225
5820 0 2225 0 5000 10000 15000
6820 0 1915
7820 0 1345
8820 0 750
9820 0 380
11020 0 225
12020 0 225
13020 0 225
14020 0 225
15020 0 225
16020 0 225
17020 0 225
18020 0 225
19355 0 225
20565 0 380
21565 0 750
22565 0 1345
23565 0 1915
24565 0 2225
25565 0 2325
26480 0 2365
27480 0 2405
28480 0 2700
29480 0 2920
30480 0 3000
TENDON reference T31 0727
0 0 5000 10000 15000 2
TENDON sequence 5 1226
0
Stressing at BOTH ENDS 0225
Y Reference line - angular deviation* (deg) 0
2500

Y
-1
Z Reference line - angular deviation* (deg)
-1
-1
*In case of curved reference line -1
x,y,z : distance from the reference line to the center of the duct -1
the reference line must be continuous -1

2225
Coordinates (mm)
x y z
LEFT END 0 1226 2500 1725

1000 1179 2455

z
1225
2000 1091 2405
3000 985 2365
725
4000 888 2340
5000 785 2330
225
5650 727 2325 0 5000 10000 15000
6650 728 2225
7650 728 1910
8650 727 1335
9650 728 745
10650 728 375
11850 728 225
12850 728 225
13850 728 225
14850 728 225
15850 728 225
16850 728 225
17850 728 225
18850 728 225
20185 727 225
21185 727 385
22185 727 755
23185 727 1350
24185 727 1915
25185 727 2225
26395 727 2325
27195 805 2330
28195 893 2345
29195 995 2370
30195 1090 2405
31195 1185 2455
32195 1226 2500
TENDON reference
TENDON sequence
Stressing at RIGHT END
Y Reference line - angular deviation* (deg)
Z Reference line - angular deviation* (deg)

*In case of curved reference line


x,y,z : distance from the reference line to the center of the duct
the reference line must be continuous

Coordinates (mm)
x y z
LEFT END

You might also like