You are on page 1of 3

TATA HITACHI CONSTRUCTION

MACHINERY COMPANY PRIVATE


Inspection Report LIMITED (DEPOT)
Near SBI Telco Campus Branch,
Telco Jamshedpur, 831004
PIN/VIN No.:0ACG-000099 Report No. 78485
Inspection date (dd/MM/yyyy)
21/09/2019 Inspected by: Gaurav Indaulia
Inspection place
Jai Surjana Mines
Customer information
312021 Unit: Birla Cement Works 312021 Chittorgarh Chanderia, Chittorgarh RJ IN
Birla Corporation Ltd. Tel 01472-256601
Machine Details
Model Code Model Name S/N Machine ID
ACG ZX650 000099 1
Annual inspection time limit (MM/yyyy)

Operated Hours (hr) Time since Delivery

13400hr(s) 6Year(s)5Month(s)
Emergency repair Condition

Urgent Immediate repair required


Overall inspection result
Engine inspection of Zx650 M/C S.No.0ACG-000099 is done.
There are multiple leakages from engine.
As engine has run 13400 hrs.,we strongly recommend that the engine should be sent to Tata Hitachi engine
workshop for complete overhauling.

Approver Morwal jee

TATA HITACHI CONSTRUCTION MACHINERY COMPANY PRIVATE LIMITED (DEPOT)


Attention: Machine (Overview) Normal: Name Plate, others
Overview Name Plate
Zx650 machine no.1,engine needs to be Zx650-0ACG-000099
overhauled.

Normal: Hour Meter Attention: Engine


Hour Meter General
HMR :13400 hrs. Leakages from tappet cover,leakage from
front seal,F.I.P. need to be arrested
inmediately.

Attention: Engine Attention: Engine


General General
Leakage from front seal.

TATA HITACHI CONSTRUCTION MACHINERY COMPANY PRIVATE LIMITED (DEPOT)


Normal: Engine Attention: Engine
Turbo Others
Liner is having lines and require replacement.

Attention: Engine Attention: Engine


Others Others
Intake and exhaust valves are worn.

Attention: Engine Attention: Engine


Others Others

TATA HITACHI CONSTRUCTION MACHINERY COMPANY PRIVATE LIMITED (DEPOT)