Overall savings Wide Range of Applications Easy Operation High Image Quality
These systems are excellent space savers and can The X-ray tube supports, with their wide range of These systems are designed with the user’s needs in The Bucky device employs the renowned oscillating
be installed swiftly. Built to have a long working movement, are ideal for a large variety of mind, and have excellent positioning characteristics. system, so clear images are a matter of course. In
life, they use fully reliable components. radiographic functions. The Bucky table has a Furthermore, the generators are provided with addition, the generators employ a high-frequency
wide range of accessories which are designed to be microprocessor and memory functions. Various inverter, ensuring a stable, high output and
easily attached (optional). They support the lateral radiographic parameters can be registered and then high-quality images.
radiographic procedure and compression of the retrieved with a one-touch operation.
abdomen, expanding the variety of examinations. Simple and easy cassette (or FPD) loading.
Tabletop protective mat reduce the burden of Just a touch is enough to operate the anatomical
patients. positioning functions.
2 3
System variations
Toshiba Radrex could maximize productivity, performance and patient care with the
variety of system for optimization of clinical application. All of Radrex system have
availability to Digital Radiography system by combining with Toshiba Portable Flat Panel
MRAD-A80S MRAD-A50S
Detector (TFD-2010A).
High Power Full System Standard System
MRAD-A32S MRAD-A25S
Compact System Basic System
4 5
Raising the standard for
productivity and performance
Availability to Digital radiography system with cassette size FPD
Reducing examination time
Providing optimum image quality
Enhancing various clinical application
6 7
Components
X-ray generator Ceiling-suspended tube support
KXO-80S KXO-50S
80 kW, 150 kV, 1000 mA
Color liquid touch panel
50 kW, 150 kV, 630 mA
One-touch control
DST-2000A DST-1000A
One-touch control Max. 140 programs (7 × 5 × 4) Column vertical movement: Approx. 170 cm Column vertical movement: Approx. 170 cm
Max. 672 programs (7 × 24 × 4) High frequency new inverter Distance from the ceiling mounting surface Distance from the ceiling mounting surface
High frequency new inverter Small foot print cabinet to the X-ray tube focus: Approx. 85 cm to 255 cm to the X-ray tube focus: Approx. 85 cm to 255 cm
Small foot print cabinet CR/DR serial communication (option) (varies depending on the X-ray tube unit and X-ray beam (varies depending on the X-ray tube unit and X-ray beam
CR/DR serial communication (option) Solidet AEC detector combination (option) limiting device used in combination.) limiting device used in combination.)
Solidet AEC detector combination (option) Locking system: Electromagnetic brake Locking system: Electromagnetic brake
KXO-32S KXO-25SC
32 kW, 150 kV, 500 mA 25 kW, 150 kV, 320 mA DS-PH-1
One-touch control One-touch control
Max. 140 programs (7 × 5 × 4) Max. 100 programs (4 × 5 × 5) Column vertical movement: Approx. 120 cm
High frequency new inverter High frequency new inverter Distance from the ceiling mounting surface
to the X-ray tube focus:
DS-TA-5A
Small foot print cabinet CR/DR serial communication (option)
CR/DR serial communication (option) ・For the angled type: Approx. 80 cm to 200 cm Floor-to-ceiling type
Solidet AEC detector combination (option) ・For the straight type: Approx. 100 cm to 220 cm Longitudial movement : 250 cm
(varies depending on the X-ray tube unit and X-ray beam Lateral movement : 40 cm
limiting device used in combination.) Vertical movement : 166 cm
Locking system: Electromagnetic brake and mechanical lock Locking system : Electromagnetic brake
8 9
Components
Bucky table Bucky table
EBT-100A Elevator-type Bucky table FBT-10A Floating-top Bucky table DTBT-10A Bucky table CBT-10A Compact Bucky table
DRX-3724HD
① Focal spot : 0.6 mm/1.2 mm
Anode heat capacity : 210 kJ (300 kHU)
① ④ Maximum rating : 40 kW/100 kW
⑤ ②
④ ③
② ⑥
⑤
③
⑥
DRX-1824B
Focal spot : 0.6 mm/1.2 mm
Anode heat capacity : 100 kJ (140 kHU)
Maximum rating : 17.5 kW/40 kW