You are on page 1of 3

Mechanical Civil Defense sample Exam

Exam duration: 90 minutes

No. of questions: 25

1 ---------. Equipment, materials, or services included in a list published by an


organization that is acceptable to the authority having jurisdiction and concerned
with e-valuation of products or services, that maintains periodic inspection of

production of listed equipment or materials or periodic evaluation. of services,


and whose listing states that either the equipment. material , or service meets
appropriate designated standards. or has been tested and found suitable a specified
purpose.
Listed . labelled.

Calibrated . approved .

2 ------Equipment or materials to which has been attached a label, symbol, or


other identifying mark of an organization that is acceptable to the authority having
jurisdiction and concerned with product evaluation. that maintains periodic
inspection of production of labeled equipment or materials, and by whose labeling
the manufacturer indicates compliance with appropriate standards or performance
in a specified manner.
Listed Labelled

Approved Certified

3--------Indicates a mandatory requirement.


Shall Should

Approved Listed

4 -If we have a sprinkler system of 300 sprinkler heads, the stock sprinkler shall
be --------
3 sprinkler 12 sprinkler
Never fewer than six 0“c

5- For extra high temperature classification, the glass bulb color shall be -------
Yellow Purple

Black blue

6-An approved or listed source of heat shall be provided for maintaining the
temperature of a pump room or pump house, where required, above ------
(4"C). (0"C).

(10"C). (6"C).

7- Where the suction pipe and pump suction flange are not of the same size, they
shall be connected with an ----------------------------installed in such a way a5 to
avoid air pockets.
Eccentric tapered reducer or Concentric tapered reducer or increaser
increaser

Flexible couplings Rigid coupling

8 – Return bends shall be used where-------------


Return bends shall not be required for deluge systems
Return bends shall not be required where dry pendant sprinklers are used
--------------
All of the above

9- Carbon dioxide hose assemblies that pass a conductivity test shall have the test
information recorded on a suitable metallic label that shall include:
Month and year the test was performed,

Name or initials of person performing the test

Name of the agency performing the test

All of the above

10-where a break tank is used, The tank shall be sized for a minimum
duration of --------------------
15 minutes with the fire pump operating at150 percent of rated capacity.
30 minutes with the fire pump operating at100 percent of rated capacity.
15 minutes with the fire pump operating at100 percent of rated capacity.
15 minutes with the fire pump operating at100 percent of rated capacity.

11-Suction and discharge piping shall be hydrostatically tested at not less than
----- psi pressure or at 50 psi (3.4 bar) in excess of the maximum pressure to be
maintained in the system, whichever is greater.
200 250
175 300

12-An internal combustion engine in which the fuel is ignited entirely by the heat
resulting from the compression or the air supplied for combustion.
Diesel engine Internal Combustion Engine.
----------- -------------------
13- A pump in which the pressure is developed principally by the action of
centrifugal force.
Centrifugal pump Vertical turbine pump
Positive displacement pump Rotary pump
14-In Qatar the used approval is--------------
ANSI / UL 405 ANSI/IEEE
------- --------------- NOTE: answer not known
15- One question of nfpa 16 but not remembered
16- Standard for the installation of stand pipe and hose system.
Nfpa 20 Nfpa 24
Nfpa 14 Nfpa 25

I cannot remember more


25- Sketch the riser diagram for a high rise building (2B+G+10) floors indicating
all details and equipments used in the system on the drawing (12 degree)
Notes :
- The pass degree is 70% .
-The exam is open book .
- The exam time is only enough for quick searching in nfpa
- the used nfpa books for firefighting engineer are (10,13,14,16,20,24,25,101,2001)

Good luck .