Sandvik

Conveyor Components
11/99

BELT ROTATION DETECTOR ES10


Rotation detector stops the belt conveyor when the speed ORDERING EXAMPLE: ES10 - 63 - 108 - C - H
lowers under the nominated minimun speed. Lowering of the
speed is always caused by some disturbances in operation
conditions and the conveyor must be stopped to clear up the Type code
disturbance. In larger conveyor systems the equipment and Tube diameter of return idler D1 (mm)
the conveyors before this belt conveyor will usually stop also.
Outer diameter of return idler D (mm)
Belt rotation detector ES10 is meant to be installed to the
return idler support. Thus are avoided the problems of the Switch type
rotation detector situated on the end of the traditional tail C = PULSE DETECTOR
pulley (for ex. rubbing the pulley into the material, often the D = PROXIMITY SWITCH
long cabling ways to the tail pulley). Installation to the Speed area of the belt
conveyor leg or other frame construction is easy. Placing near L = ( v = 0.1 ... 0.5 m/s )
the drive-end will reduct the guiding cablings on long belt H = ( v = 0.6 ... 5.0 m/s )
conveyors. Speed area of ES10 is wide; v = 0.1 m/s ... 5 m/s.
It is reliable even in frost.
In the delivery of rotating detector is include control detector
Our selection includes a compact pulse detector ( C ), and according to speed area, control disc, switch box and the
proximity switch ( D ), which is fixed to the separate rotation support with fixing screws and the stickers ’Rotation
control (not incl. in our product range). Both switches are detector’, ’switch no.- and conveyor no.’ to the switch frame.
two-wire switches. The language of the installation- and maintenance
instructions must be informed when placing the order, as well
as the language of the sign and the stickers.

ROTATION DETECTOR

SWITCH NO

Rotation belt detector is not allowed to be installed to the belt TECHNICAL PROPERTIES:
bending return idler. The idler where the detector is installed, Compact pulse detector ( C ) DI0001
must be chosen so that it is favorable and safe considering
the dirt and conditions and so that the cabling distance is short. - 20 ... 250 VAC / VDC
- Adjusting range 5 ... 300 imp/min
- IP 67
Compact pulse detector ( C ) DI0002
- 20 ... 250 VAC / VDC
- Adjusting range 50 ... 3000 imp/min
- IP 67
Proximity switch ( D ) II0012
Diameter of the standard idlers
- 20 ... 250 VAC / VDC
Support of the rotation - Adjusting range maximum 1500 imp/min
R eturn idler D1 D
indicator is meant to Roxon’s - IP 67
RA108-, RB108 63 108 return idler supports BDH6-,
RA133-, RB133 89 133
BDH9-, BDH10-, BDL4-,
RRS1-, SB10 and also for BN
L(+)
RA159-, RB159 89 159 most idler supports of other
RA219-, RB219 108 219 manufactures.
Other D and D1 measures N(-)
BU
also possible.

We reserve the right for modifications without prior notice.