You are on page 1of 33

BRITISH

COLUMBIA
CANADA
UNI
T ED 95 STATES CITY OF LEWISTON IDAHO
2

W ASHINGTON
2
Coeur
d’Alene
Pend
Orielle
Lake
STORMWATER DRAINAGE
90
95
OUTFALLS PROJECT
Moscow PROJECT LOCATION

12
Lewiston

95

M
O
N
93

TA
N
A
SN
A

U
K
8:18:33 AM

S
20

H
YELLOWSTONE

I
G
95 NATIONAL
OREGO N

H
PARK

W
93 15

A
75

Y
IDAHO

INDEX OF DRAWINGS

12
BOISE

W YOM ING
20

(D
26 IDAHO

I
84 20
R

K
I FALLS
V 26

E
Mountain
E

Home
R

B
95 PROJECT NO. DRAWING NO. DESCRIPTION
26

Y
American Falls POCATELLO

P
Reservoir

A
86

S
30 1 TITLE AND INDEX OF DRAWINGS
89

S
Twin Falls

)
2 SUMMARY OF QUANTITIES
30

EET
CLEARWATER RIVER
93 84 15 91 89
BE-370-1105 1-19 13th STREET AND DELSOL LANE OUTFALLS
NEVADA UTAH

STR
FEMA STORMWATER

ET
9th STREET
DRAINAGE PROJECT

RE
STORM DRAIN

7TH

ST
OUTFALL
BE-332-1209 1-9 9th STREET OUTFALL

H
FEMA II STORMWATER

8T
D DRAINAGE PROJECT
ST
M R
AI EE
N T
ST

E
R
EE

N
T

LA
13th STREET
STORM DRAIN

E
T

PL
EE
OUTFALL
DECEMBER 2012

DELSOL LANE

M
R

TE
STORM DRAIN

ST
OUTFALL

H
6T
EW
F
ST
N

R
EE

ET
T

RE

ET
ST

RE
USHI

H
GHW

ET
ST
AY1

9T
2 (
DI

RE
KE

TH
BY

ST
PA

10
MAI

ET
NS SS
I
DA TREE )

TH
HO

STRE
T
ST

11

T
RE

NS
ET

T
12TH

SO
13TH STREET

LN S
FER
FST

NCO
REE
T MAI

JEF
NS
TREE

LI
T
e_002.dgn

GS
TREE
T
tl

ET
es\332-1209_ti

DELSOL LANE
RE
RI I
DAH
GB

16TH STREET
O ST
FOR REFERENCE ONLY

ST
Y REE
LA T
NE GS
TREE

ER
T

LL
PA

MI
RK
ST
Not Official Bid Document

14TH STREET
RE

13
ET
l
lProject\Project Data\Sheet_Fi

15TH STREET
TH
ST
Contact Horrocks Engineers

RE
I
DAH
O ST
REE

ET
T

T: (208) 463-4197

For Official Bid Documents


VICINITY MAP
IOutfal
H:\!2012\BE-332-1209 FEMA I

DESIGNED DATE PROJECT NO.


BE-332-1209
SCALE WARNING STORMWATER DRAINAGE KDH 12/07/2012 BE-332-1209
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
N/A Nampa, ID 83687 OUTFALLS PROJECT MRW 12/07/2012 OF
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
TITLE AND INDEX OF DRAWINGS
TLH 12/07/2012
SHEET NUMBER 13TH STREET AND
9TH STREET
STATION - STATION DELSOL LANE
OUTFALL
OUTFALLS
ITEM NO. BID ITEM NO. ITEM UNIT TOTAL
1 201.4.1.A.1 Clearing and Grubbing AC 0.33 0.25 0.08
2 201.4.1.C.1 Removal of Obstructions LS 1.00 0.67 0.33
3 201.4.1.D.1 Removal of Sidewalk SY 115 115
4 201.4.1.E.1 Removal of Curb LF 307 307
7 206.4.1.A.1 Seedbed Preparation AC 0.25 0.19 0.06
8 206.4.1.B.1 Seeding AC 0.25 0.19 0.06
9 206.4.1.C.1 Mulching AC 0.25 0.19 0.06
10 206.4.1.E.1 Mulch Anchoring (tack) AC 0.25 0.19 0.06
12 206.4.1.G.1 Fertilizing AC 0.25 0.19 0.06
13 206.4.1.H.3 Loose riprap CY 113 113
14 2050.4.1.B.1 Riprap/Erosion Control Geotextile SY 223 223
15 SP-200A Permanent Sheet Piling SF 684 684

20 307.4.1.G.1 Main Line Type "P" Surface Restoration (Asphalt Roadway) SY 2856 2510 346 FOR REFERENCE ONLY
21a SP-308.4 Steel Casing Pipe Boring and Jacking, 54" (diameter) LS 1 1
21b SP-308.4 Steel Casing Pipe Boring and Jacking, 48" (diameter) LS 1.00 1.00 Not Official Bid Document
22 SP-308A Temporary Shoring LS 1.00 0.67 0.33
23 SP-308B Flowfill CY 14.60 10.80 3.80 Contact Horrocks Engineers
24 SP-308C Replace Railroad Base LS 1.00 0.67 0.33
25 302.4.1.A.1 Rock Excavation CY 20 10 10 T: (208) 463-4197

30 SP-404A Potable Water Main Crossing EA 3.00 3.00 For Official Bid Documents
31 SP-404B Potable Water Lateral Crossing EA 1.00 1.00
32 404.4.1.A.1 Water Service Connection - Size 2" EA 1.00 1.00
36 403.4.1.A.1 Hydrant EA 1.00 1.00

50 601.4.1.A.17A 12" Storm Drain Pipe, Type S, Corrugated Polyethylene (CPP) LF 192 192
51 601.4.1.A.17B 18" Storm Drain Pipe, Type S, Corrugated Polyethylene (CPP) LF 16 16
54 601.4.1.A.17E 36" Storm Drain Pipe, Type S, Corrugated Polyethylene (CPP) LF 384 8 376
55 601.4.1.A.17F 42" Storm Drain Pipe, Type S, Corrugated Polyethylene (CPP) LF 775 775
58 602.4.1.E.1C Storm Drain Catch Manhole, 72" Diameter EA 5.00 3.00 2.00
59 602.4.1.E.1D Storm Drain Catch Manhole, 84" Diameter EA 1 1
61 601.4.1.A.1A 30"X19" Elliptical, Storm Drain Pipe, Class III, RCP LF 336 336
62 601.4.1.A.1B 34"X22" Elliptical, Storm Drain Pipe, Class III, RCP LF 235 235
63 SP-602.4A Storm Drain Conflict Manhole EA 2 2
64 SP-602.4B Catch Basin - City of Lewiston Std ( Type 1) EA 9 9
68 SP-602.4F Junction Box, 6'x6' EA 1.00 1.00

70 704.4.1.C.1A Vault, width 48", height 60", length 20' EA 2 2


71 704.4.1.C.1B Vault, width 48", height 60", length 20' EA 2 2
72 706.4.1.A.5 Standard 6-inch Vertical Curb & Gutter LF 307.00 307.00
74 706.4.1.E.1 Concrete Sidewalks, thickness 4" SY 115 115
75 706.4.1.H.1 Pedestrian Ramp w/Detectable Warning Domes EA 2.00 2.00
76 SP-704A Concrete Headwall (42")
Concrete Headwall - Concrete CY 5.8 5.8
Concrete Headwall - Steel LBS 226.00 226.00
77 SP-704B Concrete Headwall (36")
Concrete Headwall - Concrete CY 2.3 2.3
Concrete Headwall - Steel LBS 89.00 89.00
78 SP 706.1A Pedestrian Curb LF 19.25 19.25

REVISIONS COMBINED PROJECTS SUMMARY DESIGN CHECKED


NO. DAT BY DESCRIPTION SCALES SHOWN ARE FOR 11" X 17"
PRINTS ONLY DETAILED
CITY OF LEWISTON, IDAHO
FILE NAME STORMWATER DRAINAGE DWG CHECKED

DRAWING DATE: OUTFALLS PROJECT


SHEET NUMBER 13TH STREET AND
9TH STREET
STATION - STATION DELSOL LANE
OUTFALL
OUTFALLS
ITEM NO. BID ITEM NO. ITEM UNIT TOTAL
80 1001.4.1.A.1 Sediment Control LS 1.00 0.67 0.33
81 1001.4.2.A.1 Staging Area EA 1.00 0.67 0.33
82 1001.4.2.B.1 Stabilized Construction Entrance EA 4 2 2
83 1003.4.1.B.1 Biofilter Bags LF 300 300
84 1001.4.A.1 Silt Fence LF 75 75
90 1103.4.1.B.1 Traffic Control LS 1.00 0.67 0.33

100 SP-2000A Project Quality Control LS 1.00 0.67 0.33


101 2010.4.1.A.1 Mobilization LS 1.00 0.67 0.33

FOR REFERENCE ONLY

Not Official Bid Document

Contact Horrocks Engineers

T: (208) 463-4197

For Official Bid Documents

REVISIONS COMBINED PROJECTS SUMMARY DESIGN CHECKED


NO. DAT BY DESCRIPTION SCALES SHOWN ARE FOR 11" X 17"
PRINTS ONLY DETAILED
CITY OF LEWISTON, IDAHO
FILE NAME STORMWATER DRAINAGE DWG CHECKED

DRAWING DATE: OUTFALLS PROJECT


BRITISH
COLUMBIA
CANADA
UNI
T ED 95 STATES CITY OF LEWISTON IDAHO
2

W ASHINGTON
2
Coeur
d’Alene
Pend
Orielle
Lake
13th STREET AND DELSOL LANE OUTFALLS
90
95
FEMA STORMWATER DRAINAGE PROJECT
11:48:00 AM

Moscow PROJECT LOCATION

12
Lewiston

95

M
O
N
93

TA
CLEARWATER RIVER

N
A
SN
A
K
E

20 RA DWG.
YELLOWSTONE ILR
95 NATIONAL OA NO. 6
OREGO N

PARK D
SP RA
93 15 UR I
75 LRO
IDAHO LI
NE AD
BOISE
SP
UR
INDEX OF DRAWINGS
DECEMBER 2012

W YOM ING
20 LI
NE
IDAHO RAI
LROAD
84 20 26 DWG. USHI
R

I
V FALLS 26 MAI GHWAY12(
DI
Mountain NLI KEBYPASS)
NE
E

Home NO. 4
R

95 MAI DRAWING NO. DESCRIPTION


26 American Falls POCATELLO NS
Reservoir
TREE
T
86
30 1 TITLE, LEGEND AND INDEX OF DRAWINGS
Twin Falls 89
2 GENERAL NOTES
13TH STREET
30 3 SURVEY CONTROL
STORM DRAIN
93 84 15 91 89
4 - 7 PLAN AND PROFILE
NEVADA UTAH OUTFALL 8 CONFLICT MANHOLE DETAILS

ET
DELSOL LANE 9 SERVICE CONFLICT AND PEDESTRIAN RAMP DETAILS

STRE
DWG. 10 DETAILS
STORM DRAIN
NO. 5 11 TRAFFIC CONTROL DETAILS AND GENERAL NOTES
OUTFALL
12 US 12 CROSSING DETAILS (13TH ST)

12TH
13 US 12 CROSSING DETAILS (DELSOL LN)

T
LN S
14 - 15 HEADWALL DETAILS
16 TRAFFIC CONTROL

LEGEND 17 - 18 REMOVAL AND ASPHALT REPLACEMENT PLAN

NCO
13TH STREET
19 CRITICAL ACCESS PLAN

LI
FST MAI

T
REE NS

NS
WM EXISTING WATER METER T TREE
T

DELSOL LANE
SO
EXISTING VALVE

16TH STREET
FER
e.dgn

HYD EXISTING FIRE HYDRANT

JEF
tl

EXISTING IRRIGATION SPRINKLER


\370-1105_ti

I
DA
HO GS
ST TREE
EXISTING STORM DRAIN MANHOLE RE T
ET
EXISTING STORM DRAIN INLET N
l
SolOutfal

EXISTING SANITARY SEWER MANHOLE

EXISTING STREET LIGHT

GS
TREE
cs\13th_Del

EXISTING GUY WIRE ANCHOR


T
ET
RE

EXISTING ELECTRICAL BOX


ST

RI
GB I
DAH
EXISTING SIGN Y O ST
ER

LA REE
NE T
FOR REFERENCE ONLY
LL
i
es\Hydraul

MI

EXISTING SIDEWALK AND CURB

EXISTING TREE OR SHRUB


PA
RK
Not Official Bid Document
l
on\BE-370-1105\Sheet_Fi

ST
RE
ET
PROPOSED STORM DRAIN LINE
Contact Horrocks Engineers

14TH STREET
PROPOSED STORM DRAIN MANHOLE
13

15TH STREET
T: (208) 463-4197
TH

PROPOSED STORM DRAIN INLET


I
ST

DAH

DELSOL LANE
O ST
REE
RE

16TH STREET
For Official Bid Documents
ET

NOTE:
SEE LEGEND ON PLAN AND PROFILE SHEETS FOR THE
FOLLOWING EXISTING UTILITIES:
tigati

EXISTING FIBER OPTIC


nage Mi

EXISTING GAS
EXISTING IRRIGATION
EXISTING OVERHEAD ELECTRICAL
FEMA Storm water Drai

EXISTING SANITARY SEWER


EXISTING STORM DRAIN
EXISTING TELEPHONE VICINITY MAP
EXISTING WATER
EXISTING PUBLIC WATER LATERAL
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
N/A Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 1 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE TITLE, LEGEND AND INDEX OF DRAWINGS JRS 12/03/2012
1
GENERAL CONSTRUCTION ROADWAY
1. All construction work shall conform to the City of Lewiston Standards and Specifications and the current version 1. All Contractors working within the public road right-of-way are required to secure a right-of-way construction
of the Idaho Standards for Public Works Construction (ISPWC). In the case of conflict, the Project Plans and permit from the City of Lewiston at least twenty-four (24) hours prior to any construction.
Technical Specifications will prevail over City Standards which will prevail over ISPWC.
2. The City of Lewiston will inspect all work within the public rights-of-way to include utility trenches above the pipe
2. All Contractors and Utility Contractors shall attend a pre-construction conference (and on-site meeting with the zone. The City will inspect all connections to existing infrastructure (water, sewer, and storm drain).
City of Lewiston Public Works Supervisor) prior to start of work. The Contractor shall conduct a weekly project
11:48:02 AM

meeting with the Engineer and City. WATER/SEWER


1. Construction of potable water lines shall conform to the standards in the "Idaho Rules for Public Drinking Water
3. Contractors shall notify the appropriate agency when materials are on site or inspection of the work is required. Systems (IDAPA 58.01.08)" as well as the standards and specifications referred to in General Construction
No work may begin on any project without Twenty Four (24) hour prior notice. Note No. 1.

4. Work subject to approval by any governmental agency must be approved prior to (A) backfilling trenches for 2. The horizontal separation of potable water mains and non-potable water mains (sanitary sewer, storm drain, and
pipe; (B) placing of aggregate base; (C) placing of concrete; (D) placing of asphalt paving. All newly installed irrigation) shall be a minimum of ten (10) feet. Where it is necessary for a potable water main and non-potable
lines shall be videoed per Public Works Standards prior to final payment. water main to cross with less than eighteen (18) inches of vertical separation, the crossing shall be constructed
in accordance with Section 542.07 of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08) and
DECEMBER 2012

5. Inspection, approval and final acceptance of all construction shall be by the Public Works Department, and Section 430.02 of the Wastewater Rules (IDAPA 58.01.16).
their decision shall be final. Such inspections shall not relieve the contractor from the responsibility of performing
the work in an acceptable manner in accordance with the DEQ approved construction plans. 3. The Contractor shall be responsible for notifying existing water users prior to disrupting service. No user shall be
without water or sewer service overnight. No user shall be without water for more than 4 hours during normal
6. Any deviation from the approved plans and specifications must have the applicable agency approval in writing business hours. The service line crossing the railroad tracks at the 13th Street Storm Drain Outfall may be out of
prior to construction. service for an extended period of time, not to exceeed 1 month.

7. The Contractor shall promptly remove from the vicinity of the completed work, all rubbish, mud in streets, 4. All water works components shall be ANSI/NSF 61 Certified, and must meet all AWWA and standard requirements
removed materials, all excess material, construction equipment and temporary structure and facilities used of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08). The Contractor shall give the Engineer
during construction. Final acceptance and payment will be withheld until the Contractor has satisfactorily 2 weeks advance notice of the time of installation to provide valves provided by the City.
cleaned the site as determined by the Public Works Supervisor.
STORM SEWER
\370-1105_GeneralNotes.dgn

8. Contractor shall maintain critical access points as shown in the plans. Properties with water and sewer services 1. All catch basins and manholes shall be constructed per City of Lewiston, Idaho Public Works Department Standards.
impacted by construction activities shall be notified of construction activities 2 days prior to disturbing their See drawings 6-1 through 6-9 for drawing details. Stormwater Type 1 Catch Basin, Std. Dwg 6-8 shall be provided
service(s). at all locations where pipe sizes permit. Stormwater Type 1a Catch Basin, Std. Dwg 6-9 shall be provided at all
locations where larger pipe sizes require their use. All catch basins shall have curb openings unless it is located
9. The design, construction, installation, maintenance and materials to complete a temporary dewatering system to within a driveway. Curb openings may be eliminated only in special circumstances and only as approved by the
provide adequate dewatering during construction will not be measured and paid for separately but included in the Engineer. Where inlet locations have moved along the curb from the existing location to a new location, the flow line
l
SolOutfal

project. of the gutter shall be formed to ensure positive drainage to the new inlet location. Slopes shall not exceed 20%
unless approved by the Engineer. Field verification that gutter flow can be achieved shall be performed by the
contractor prior to the installation of the inlet.
cs\13th_Del

2. Removal of existing storm drain manholes, catch basins, and pipe within the project limits shall be incidental to the
i
es\Hydraul

new pipe, manhole or inlet being installed in the same or nearby location. The City will retain ownership of all
FOR REFERENCE ONLY removed frames, grates, and lids. Contractor shall stockpile removed items in the location designated by the City.
Pipes, catch basins, inlets and manholes that shall be removed or abandoned are shown on the removal plan.
Not Official Bid Document
l
on\BE-370-1105\Sheet_Fi

Pipes to be abandoned shall be plugged at the disconnected end with a concrete plug. Manholes deeper than
4 feet, and not in conflict with proposed storm drainage, may be abandoned by removing the top 4 feet of the
Contact Horrocks Engineers
manhole riser and backfilling with 34" aggregate or flowable fill. Compaction within and above the abandoned
T: (208) 463-4197 manhole shall be required.

For Official Bid Documents 3. All manhole lids shall be rotated on structure so they are out of wheel paths.
ti
nage Mi gati

4. Locations are called out in the plans to connect existing storm drain components to new storm drain components.
All work and materials for connections shall be considered incidental to the new storm drain components. Industry
FEMA Storm water Drai

standard connections shall be used. When coring and grooving is required, a non-shrink grout shall be used.
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
N/A Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT TLH 11/27/2012 2 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE GENERAL NOTES JRS 12/03/2012
2
ET
ST

ST R

STRE
2ND

3RD
C ST
REET 3RD AVE
NUE N

4TH

ET
LEWISTON SURVEY CONTROL
D ST

RE

D
REET

IK
ST
ET

E
CONTROL POINT 1A
D STR

B
EET N 1734533.069

STRE

Y
H
N

P
E 2302172.355

7T

A
ELEV. 831.617

S
S
CITY MONUMENT

6TH
MAI
N ST U
REET S CONTROL POINT 2A
CT BOUL
EVAR H
PE

T
D IG N 1734566.387
OS

E
PR H E 2307752.025

RE
W
A ELEV. 741.815
11:48:05 AM

ST
Y CONTROL 0 250 500 1000
N CITY MONUMENT
O POINT 22C
PROSPECT BOULEV ARD

H
12

8T
NORTH STREET CL CONTROL POINT 51
SURVEY FEET EA
F RW N 1734024.882

E
N
S AT E 2303621.906

A
T
R ER

L
E ELEV. 838.897
E RI

T
T

E
VE FND TRUES #18

T
R

E
R

E
1
ST AVENUE

T
D

R
S

T
S
M T PROJECT SURVEY CONTROL

S
R

H
A E

T
IN E

H
IX
T

T
S
T

9
R CONTROL POINT 20
E
E

W
T N 1734972.690

E
N
E 2306881.626
2ND AVENUE F ELEV. 749.717
3RD STREET

5TH STREET
4TH

S
DECEMBER 2012

GLASS W AY

T
R
E CONTROL POINT 22C
E
T N 1735697.143
STREET

CONTROL
E 2304750.379
POINT 20

T
ELEV. 749.011

E
MA
I

RE
N DI
ST KE B
RE YPAS

ST
3RD AVENUE ET S
US
3RD AVENU IDA HI
GHW
E

TH
HO F AY

E
ST 13TH STREET NO
1

RE
ST

11
RE 2

12TH
RE ET STORM DRAIN

ST
ET OUTFALL
ST

ET

T
ET

E
H

RE
JO

6TH STRE

9T

STR
FUTURE

13TH STRE
DELSOL LANE CONTROL

T
H

STORM DRAIN

ST
E
CONTROL STORM DRAIN POINT 2A
N’

RE

T
POINT 1A (TYP.)
S

ET
OUTFALL

ET
E
N
ST

RE
T

SO
W

E
MA

E
IN
AY

ST

STR
RE
ST

TH

ER
RE
F ET

10

ST
ST

FF

LN
4TH AVEN RE
UE ET

H
JE

CO

NE
TH

18T
I

11
DA

REET
LIN

DELSOL LA
T
HO

NE

E
ST

RE
\370-1105_surv_001.dgn

RE

LA
CONTROL ET

ST

16TH ST
5TH AVEN
UE POINT 51

S
G FUTURE
CHURCH S MA

AM

TH
ST
ET

TREET IN
5TH AVEN
RE
ET
STORM DRAIN ST
FOR REFERENCE ONLY

T
RE

AD
RI

12
UE ET

E
3RD STRE

(TYP.)
ET

GB

RE
Y
LA
4TH STRE

ST
NE
Not Official Bid Document
ET

I
DA
HO G
ET

ER
ST ST
7TH STRE

RE RE
ET ET

LL
8TH STRE

PA
6TH AVEN RK

MI
UE
Contact Horrocks Engineers
l

ST
SolOutfal

RE
ET

ET
6TH AVEN

E
UE

14TH STRE
A
ET

ET

ET
T: (208) 463-4197
R
ET

G
5TH STRE
cs\13th_Del

11TH STRE

15TH STRE
6TH STRE

I
DA
ET

HO
ST

NE
RE
ER

ET
For Official Bid Documents
9TH STRE

ET

REET
DELSOL LA
LL

10TH STRE
MI
i

ET
es\Hydraul

16TH ST

ET
7TH AVEN
UE
3RD STRE

E)
ET

6TH AVEN

17TH STRE
UE

ET
AD
4TH STRE

18TH STRE
GR

ET
l

6T
on\BE-370-1105\Sheet_Fi

OE
AV

14TH STRE
8TH AVEN 7TH AVEN EN
UE UE UE

(P

ET
13TH STRE
7TH AVENUE
8TH AVEN
UE
7TH AVEN
UE
ET

ET
6TH STRE

ARD
8TH AVEN BOULEV
ET

UE
7TH STRE

ET

ET
8TH STRE

9TH AVEN
ET

UE
9TH STRE

ET
10TH STRE

NOTES:
11TH STRE

ET
gati

12TH STRE

ET
13TH STRE
ti

1. All Units are in U.S. Survey Feet, Grid Values are SPC Zone

14TH STRE
nage Mi

ET

REET
1103 (Idaho West), Geodetic Values are NAD83(1998/1999).
ARD
BOULEV

15TH STRE
Elevations are NAVD88.

T
9TH AVEN
UE

E
16TH ST
8TH AVEN

E
UE
FEMA Storm water Drai

2. To convert ground distances to State Plane Grid distances,

R
T
scale using a combined factor of 1.00001547 (Pt 2A). The

S
1
0 TH AVENU
E difference between grid distances and ground distances does
9TH AVEN

H
UE

T
not exceed 1:15,000 for the Idaho West Zone at all locations
ET
ET

18
within this project so scaling may not be necessary depending
6TH STRE
3RD STRE

ET

9TH AVEN on accuracy requirements.


UE
4TH STRE

1
0 TH AVENU
E
9TH AVEN
UE
1
1TH AVE
NUE
1
0 TH AVENU
H:\!2011\BE-370-1105

E
DESIGNED DATE PROJECT NO.

SCALE WARNING 5700 East Franklin Rd. 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
HORIZONTAL 0 1/2 1 Suite 160 DRAWN DATE SHEET NO.

1"=500’
5700 East Franklin Rd.
Suite 160
Nampa, ID 83687
(208) 463-4197

Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 3 OF 21


IF THIS BAR DOES NOT (208) 463-4197
VERTICAL CHECKED DATE DRAWING NO.
REV DATE BY DESCRIPTION MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
SURVEY CONTROL 3
JRS 12/03/2012
12"
HY

NE

NE

LROAD

GHW AY 12/
NE
N STREET
NOTES:

LROAD SPUR LI

LROAD SPUR LI

N LI
D

KE BYPASS
M AI
RAI
3 Removal of Sidewalk, Item 201.4.1.D.1
0 20 40 80

M AI
WM

US HI
4 Removal of Curb, Item 201.4.1.E.1
SEE DETAILS FOR

DI
ADDITIONAL INFORMATION
SURVEY FEET WATER SERVICE 83 7 Seedbed Preparation, Item 206.4.1.A.1

RAI

RAI
FUTURE 42" LINE; FIELD VERIFY;
CONSTRUCTION LIMITS SHALL NOT RETAIN & PROTECT
STORM DRAIN
EXTEND WESTWARD BEYOND THE 8 Seeding, Item 206.4.1.B.1
BORE AND LINE
14TH ST VACATED ROW
75’
9 Mulching, Item 206.4.1.C.1
63 14TH STREET VACATED 60’
AM

RIGHT-OF-WAY 83
N 1734934.79 FT EXCAVATION LIMITS 10 Mulch Anchoring (tack), Item 206.4.1.E.1
11:48:18

IN MAIN-PL DR NW FROM 1.5:1 SLOPE


E 2305599.40 FT
5 2.7SY, 10LF STA = 10+00.00 L5B
8’ STUBOUT N 1734957.62 FT 12 Fertilizing, Item 206.4.1.G.1
74 72 4 3 N 1734705.133 22 20
FOR FUTURE TEMPORARY E 2305604.63 FT
55 E 2305574.619 70 EXISTING
CONNECTION, SHORING
LIMITS OF 13TH STREET 13 Loose Riprap, Item 206.4.1.H.3
CAP END 14’
EXCAVATION FOR OUTLET
MH 0-4 (MIN) 30’ TEMPORARY 62 70 SINGLE TRENCH BOX

15"
MH MAIN-OUTLET 20 3 83 14 Riprap/Erosion Control Geotextile, Item 2050.4.1.B.1
STA = 40+21.08 64 4 SHORING
STA = 40+00.00 N 1734661.383

12"
N 1734640.915 E 2305572.877 LATERAL 5B 15 Permanent Sheet Piling, Item SP-200A
1
E 2305567.824

25’
30 50 24 Mainline Type "P" Surface Restoration

55’
20

20’
10’
68 WM (Asphalt Roadway), Item 307.4.1.G.1

85’
31 (See "REMOVAL AND ASPHALT
REPLACEMENT PLAN 1")
73’ Steel Casing Pipe Boring and Jacking, 54" (diameter),
A
DECEMBER 2012

21
L4

50 32 Item SP-308.4
1 55 55 BORE LENGTH 55 15 (30 LF) (360 SF)
RA

119’
23 22 Temporary Shoring, Item SP-308A
TE

74 72 4 3 1 LATERAL 5A 58 CASING LENGTH 7 8 9 10 13 14


12 76
LA

NEW (228 SF) 2


23 Flow Fill, Item SP-308B, See Detail
10.8SY, 13LF 55 STORM DRAIN
64 REMOVE & MH 13AR UP N 1734945.58 FT PERMANENT
50 EASEMENT
RESET EXISTING 22 STA = 42+47.14 REMOVE & E 2305658.29 FT STORMDRAIN 24 Replace Railroad Base, Item SP-308C
64 5
8’ STUBOUT N 1734883.203 RESET EXISTING EASEMENT
IRRIGATION BOTTOM OF 21
FOR FUTURE E 2305615.813 IRRIGATION
55 BOX PUSH PIT
CONNECTION, 30 Potable Water Main Crossing, Item SP-404A
IN MAIN-PL DR-SE BOX
CAP END WM
STA = 10+00.00 L4A MH_13TH_MAIN-02 MH 13AR DWN
31 Potable Water Lateral Crossing, Item SP-404B
N 1734625.669 IN MAIN-PL DR NE STA = 40+64.92 LIMITS OF 3 RETAIN & STA = 42+97.93

NE
NE
E 2305589.384 STA = 10+00.00 L5A N 1734703.760 EXCAVATION RETAIN & PROTECT; N 1734932.709

NE
PROTECT
32 Water Service Connection, Size 2", Item 404.4.1.A.1

LROAD SPUR LI
LROAD SPUR LI
N 1734698.851 FOR PUSH PIT RAIL TO REMAIN

N LI
E 2305584.114 RAIL, TIES E 2305627.139
WM E 2305601.417 OPEN AT ALL TIMES

GHW AY 12/
AND
12" Storm Drain Pipe, Type S, Corrugated Polyethylene

LROAD M AI
SECTION N 1734921.62 FT 50
(CPP), Item 601.4.1.A.17A
N STREET

KE BYPASS
74 72 4 3 E 2305652.81 FT
FUTURE 42" 42" Storm Drain Pipe, Type S, Corrugated Polyethylene
1.9SY, 10LF CLEARWATER PAPER 55
STORM DRAIN (CPP), Item 601.4.1.A.17F
ACOE EFFLUENT LINE

US HI
BOUNDARY
NOTE:

RAI

RAI

RAI
M AI

DI
Remove and reset existing irrigation boxes is incidental to
steel casing pipe boring & jacking.
\370-1105_hydr_005.dgn

N)
h

* REFER TO DRAWING 4A FOR


N)

n 13t

47 (

N)
SE)

S)
60 (
W)

FOR REFERENCE ONLY ADDITIONAL NOTES


E)

13 (
OUTLET

W)
47 (

02

E)
S)
NV OUT = 723.
ctM ai
60 (
27 (
60 (

08
NV OUT = 723.

N-

76 (
13 (
40 (
00

NV OUT = 723.
STA = 40+21.

30’
N = 723.

92
32

M H_13TH_M AI
STA = 40+00.

N = 723.
N = 733.
N = 723.

745 745
LEGEND
76

STA = 40+64.
M = 738.

N = 732.
N = 723.
N = 733.

C
L OF RR
35

Not Official Bid Document


i
M = 737.
N-

M H Confl

M = 737.

SPUR LINE
M H_M AI

EXISTING FIBER OPTIC

N)
N)
N)
N)
N)
NV I

N)
NV I
NV I
NV I

EXISTING GAS

54 (
54 (
54 (
54 (
54 (
NV I
NV I
NV I

S)
RI
l

Contact Horrocks Engineers

13 (
SolOutfal

S)
S)
S)
S)
S)
RI

I
I

EXISTING IRRIGATION

54 (
RI

NV OUT = 721.
NV OUT = 721.
NV OUT = 721.
NV OUT = 721.
NV OUT = 721.
I
I
I
I

11 (
11 (
11 (
11 (
11 (
740 740

14
I
I
I
I

NV OUT = 721.
M H_13AR_DW N
93
EXISTING OVERHEAD ELECTRICAL

M H_13AR_UP
STA = 42+47.

N = 721.
87

STA = 42+97.

N = 721.
N = 721.
N = 721.
N = 721.
N = 721.
35
EXISTING SANITARY SEWER

M = 731.
T: (208) 463-4197

M = 731.
cs\13th_Del

EXISTING STORM DRAIN

NV I
12" P_MAIN-PL_NW EXISTING TELEPHONE

NV I
NV I
NV I
NV I
NV I
735 735

RI
For Official Bid Documents EXISTING WATER

RI
I
I
I
I
I
I
12" P_MAIN-PL_NE 1

I
I
I
I
I
I
HYDRAULIC GRADE LINE
i
es\Hydraul

EXISTING 15" STEEL EXISTING CLEARWATER EXISTING GROUND


1 6
STORM DRAIN PIPE PAPER EFFLUENT LINE
12" MAIN-OUTLET_SE
730 730
54" STEEL CASING
l
on\BE-370-1105\Sheet_Fi

42" MAIN_JefftoOutlet

2’
Headwall
BOTT
INV. OM OF T
DICH

725 ELEV. 725 USHI


GHWAY12
720.49

MAI
NST
REE
T

10’

ET
P_13_Out
let
_Mai
n-PL P13t
hMa in-
PL

TRE
42I
NCH CONTRACTOR SHALL
720 42I
NCH P_13T 720

NS
H-BORE

2’
LOCATE PIPE AND

13TH STREET
L=15’ FST
L=38’ 42I
NCH P_ARRAYOF5PI REE

SO
T
PROTECT IN PLACE PES
S=0 .
91% P_13 N

DELSOL LANE
TH_

EET
S=0 OUT

FER
.91% L=177 22"
x34"ELLI
PT FALL
gati

’ I
CALPIPES
42I
NCH

JEF

STR
S=0 .
91% L=4 7’
L=69
ti

S=0 .
88% ’ GS
T

LN
REE
nage Mi

T
STUBOUT STORM DRAIN PIPES S=0 .
91%

NCO
715 AND CAP ENDS 715

LI
I
DA

15TH STREET
PERMANENT HO
ST
GS
TREE
RE T
FEMA Storm water Drai

ET
SHEET PILING

ET
I
DAH

16TH STREET
RE
O ST
REE
T

ST
ER
LL
710 710

MI
40+00 41+00 42+00 43+00 44+00

KEY PLAN
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 40’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 4 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE
13TH STREET OUTLET PLAN AND PROFILE - 1 4
JRS 12/03/2012
JEFFERSON STREET
NOTES:

NCOLN STREET
FUTURE 36"
STORM DRAIN

3 Removal of Sidewalk, Item 201.4.1.D.1


16SY, 31LF 8’ STUBOUT FOR FUTURE
CONNECTION, CONNECT
75 74 72 4 3 54 4 4 Removal of Curb, Item 201.4.1.E.1
TO EXISTING 15" STEEL
STORM DRAIN PIPE
IN MAIN-JEFFERSON-SE

LI
12" Storm Drain Pipe, Type S, Corrugated Polyethylene
50
STA = 10+00.00 L3B MH MAIN-JEFFERSON (CPP), Item 601.4.1.A.17A
FUTURE MH MAIN-LINCOLN
N 1734576.125 STA = 32+32.12 18" Storm Drain Pipe, Type S, Corrugated Polyethylene
STA = 30+00.00 51
E 2305813.310

WM
N 1734591.326 (CPP), Item 601.4.1.A.17B
N 1734540.218

WM
WM
E 2305790.222

WM
FUTURE IN MAIN-
11:48:30 AM

E 2306016.648 36" Storm Drain Pipe, Type S, Corrugated Polyethylene


CONTRACTOR SHALL 54

WM
LINCOLN-SE 8’ STUBOUT (CPP), Item 601.4.1.A.17E
FIELDVERIFY DEPTH OF

HYD
STA = 10+00.00 L3A FOR FUTURE FUTURE 42"
FUTURE 18" EXISTING STORM DRAIN 55 4 42" Storm Drain Pipe, Type S, Corrugated Polyethylene
N 1734522.597 CONNECTION, STORM DRAIN 55
STORM DRAIN AND CONNECT TO INLET (CPP), Item 601.4.1.A.17F

6"
E 2306056.359 CAP END
64
59 Storm Drain Manhole, 84" Diameter, Item 602.4.1.E.1D
LAT 2
Catch Basin - City of Lewiston Std (Type 1),

6"
2" ER 64
F AL
UT 3 Item SP-602.4B
URE 50 B
LATERA

2"
L3A 72 Standard 6-inch Vertical Curb & Gutter, Item 706.4.1.A.5

15" 3 74 Concrete Sidewalks, Thickness 4", Item 706.4.1.E.1

15" Pedestrian Ramp with Detectable Warning Domes,


2"
1 MAI
NSTREET 75
2"
1 2"
1 59 Item 706.4.1.H.1
2"
1
8’ STUBOUT 2"
1
DECEMBER 2012

FOR FUTURE
2" 4 55 1 1 Connect to Existing Storm Drain
CONNECTION, 2"
CAP END
Refer to Lateral Profile Sheets for Pipe Lateral
2
Elevations and Profiles

3 Contractor shall field locate existing storm drain and

WM

WM
connect to 84" manhole. connection at this location

"
is needed to provide drainage from the 13th Street

WM
drainage area during installation of the 13th Street
FUTURE IN-MAIN-JEFF-N Outlet and Outfall. Connection shall not be paid for

WM
N N 1734628.765 separately but shall be incidental to Storm Drain
E 2305797.334 CONTRACTOR SHALL FIELD VERIFY Manhole, 84" Diameter, Item 602.4.1.E.1D.
CONNECT TO DEPTH OF EXISTING STORM DRAIN
EXISTING STORM AND CONNECT TO MH_MAIN-JEFFERSON Cap pipe prior to backfill. See "PIPE CAP DETAIL".
4
DRAIN PIPE Pipe cap shall be incidental to the pipe stubout.

0 20 40 80
1. Northings and Eastings are shown to the center of
manhole and center of catch basin at face of curb

SURVEY FEET
\370-1105_hydr_003.dgn

FOR REFERENCE ONLY


NCOLN

750
Not Official Bid Document 750
LEGEND
W)
LI

JEFFERSON

W)
SE)
N-

03 (

SE)

48 (
E)

S)
EXISTING FIBER OPTIC
FUTURE M H_M AI

13 (
NV OUT = 731.

56 (
36 (
54 (
NV OUT = 724.
Contact Horrocks Engineers
00

EXISTING GAS

12
l

STA = 30+00.
SolOutfal

N = 734.

STA = 32+32.
86

N = 728.
N = 733.
N = 724.
EXISTING IRRIGATION

54
M = 738.

745 745

M = 738.
N-
EXISTING OVERHEAD ELECTRICAL

M H_M AI
T: (208) 463-4197 EXISTING SANITARY SEWER
NV I

NV I
NV I
NV I
cs\13th_Del

EXISTING STORM DRAIN


RI

RI
I
I

I
I
I
I
EXISTING TELEPHONE
740 For Official Bid Documents 740
EXISTING WATER
HYDRAULIC GRADE LINE
i
es\Hydraul

EXISTING GROUND
STUBOUT STORM DRAIN
PIPE AND CAP END
735 735
l
on\BE-370-1105\Sheet_Fi

12" P_MAIN-JEFF_SE 2 BOTTOM OF T


DICH

730 730 USHI


GHWAY12
FUTURE
12" MAIN-JEFF_SE
MAI
FUTUREMAI
N_Li
n
NST
REE
col
n-t
o-J
e f
fer
son T
18I
NCH

ET
Existing 15" Steel Storm Drain

TRE
L=227’
725 Approx. Inv elev = 726.34 725

NS
S=1.09%

13TH STREET
Connect to manhole FST
REE

SO
T
N

DELSOL LANE
EET
FER
gati

JEF

STR
2 36" JEFFERSON_FtoMain FUTUREMAI
ti

STUBOUT STORM DRAIN N_Jef


ft
oOut
let GS
T

LN
REE
nage Mi

T
42I
NCH

NCO
PIPES AND CAP ENDS
720 L=22 720
1 ’

LI
I
DA
S=0 .
40%

15TH STREET
HO GS
ST TREE
RE T
FEMA Storm water Drai

ET

ET
I
DAH

16TH STREET
RE
O ST
REE
T

ST
ER
LL
715 715

MI
30+00 31+00 32+00 33+00 34+00

KEY PLAN
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 40’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 5 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
CHECKED
REV DATE BY DESCRIPTION MEASURE 1" THEN MAIN STREET PLAN AND PROFILE - 1
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE 5
JRS 12/03/2012
NOTES:

58 Storm Drain Manhole, 72" Diameter, Item 602.4.1.E.1C

LATERAL 5A LATERAL 5B 62
22"X34" Elliptical, Storm Drain Pipe, Class III, RCP,

FOR REFERENCE ONLY Item 601.4.1.A.1B (Refer to 13th Street Outlet Detail)

63 Storm Drain Conflict Manhole, Item SP-602.4A


750 750

Not Official Bid Document 64


Catch Basin - City of Lewiston Std (Type 1),
Item SP-602.4B

N)

N)
W)

E)
13 (

13 (
W)

W)
02

02
00 L5B
E)
S)

E)
S)
PL DR_NW

50 (
00 L5A
11:48:33 AM

68 Junction Box, 6’x6’, Item SP-602.4F

PL DR_NE

03 (

N-

N-
Contact Horrocks Engineers

76 (
13 (
40 (

76 (
13 (
40 (
NV OUT = 723.

NV OUT = 723.
15
59

11
NV OUT = 733.
96

M H_13TH_M AI

M H_13TH_M AI
NV OUT = 733.
745 745 Vault, width 48", height 60", length 20’,

GRATE = 737.
STA = 10+17.

STA = 10+09.
GRATE = 736.
70

N = 732.
N = 723.
N = 733.

N = 732.
N = 723.
N = 733.
STA = 10+00.
35

35
STA = 10+00.
Item 704.4.1.C.1A (Refer to 13th Street Outlet Detail)

M = 737.

M = 737.
N-
T: (208) 463-4197

N-
72 Standard 6-inch Vertical Curb & Gutter, Item 706.4.1.A.5

N_M AI
N_M AI

NV I
NV I
NV I

NV I
NV I
NV I
74 Concrete Sidewalks, Thickness 4", Item 706.4.1.E.1

RI

RI
740 740
For Official Bid Documents

I
I
I
I

I
I
I
I
I

I
I

I
Concrete Headwall (42"), Item SP-704A
76
(Refer to Headwall Details)

83 Biofilter Bag, Item 1003.4.1.A.1

735 735

WATER LATERAL
4 Refer to Lateral Profile Sheets for Pipe Lateral
CONFLICT 1
Elevations and Profiles
DECEMBER 2012

12" P_MAIN-PL_NW 12" P_MAIN-PL_NE

730 730 54" Steel Casing Begins 30 feet South from Center Line
2
of Rail Road Spur Line; Ends at Vault

42" P_13TH-BORE 42" P_13TH-BORE Area disturbed by pit shall be restored to the existing
3
condition. Pavement replacement shall be paid for
as Item 307.4.1.G.1. Curbing, landscaping, irrigation
water lines, fence and planting shall all be incidental to
725 725
42" P 13th Main-PL 42" P 13th Main-PL the SP 308.4.
Existing mapping indicates a water line is in conflict
4
with existing inlet. Contractor shall field verify the
P_MAIN-PL P_MAIN- depth of the water line and avoid the conflict or
_NE PL_NW
12I
NCH 12I
NCH adjust the waterline depth.
720 L=1 720
4’ L=5’ Cap pipe prior to backfill. See "PIPE CAP DETAIL".
S=2 5
.00% S=2.00% Pipe cap shall be incidental to the pipe stubout.

715 715

10+00 L5A 10+00 L5B 1. Northings and Eastings are shown to the center of
manhole and center of catch basin at face of curb
\370-1105_hydr_005A.dgn

* REFER TO DRAWING 4 FOR


LATERAL 4A LATERAL 3B ADDITIONAL NOTES

JEFFERSON_SE
750 750

JEFFERSON

W)
LEGEND

W)

SE)
N)

48 (
E)

S)
SE)
W)

00 L3B
60 (

19 (
W)
E)

56 (
36 (
54 (
OUTLET

NV OUT = 724.
00 L4A
PL DR_SE

53
70 (

60 (
27 (
60 (

95
l

NV OUT = 723.
SolOutfal

NV OUT = 734.

STA = 10+27.
30

N = 731.
N = 733.
N = 724.
GRATE = 737.

54
EXISTING FIBER OPTIC
01

STA = 10+00.
NV OUT = 733.

STA = 10+26.

N = 723.
N = 733.
N = 723.

745 745

M = 738.
N-
76
GRATE = 737.
STA = 10+00.

M = 737.
N-

M H_M AI
N-
M H_M AI

EXISTING GAS

N_M AI
N-

NV I
NV I
NV I
cs\13th_Del

N_M AI

NV I
NV I
NV I

RI
I
I
I
I
RI

EXISTING SANITARY SEWER

I
I
I
I
I

740 740
I

EXISTING TELEPHONE
i
es\Hydraul

EXISTING WATER
735 735
18" MAIN_Lincoln-to-Jefferson
HYDRAULIC GRADE LINE
l
on\BE-370-1105\Sheet_Fi

EXISTING GROUND
P_MAI
MAI
N-OUT N-
JEF
730 LET_SE 12I F_SE 730
12I NCH
NCH
L=23 36" JEFFERSON_FtoMain
L=22’ ’
42" MAIN_13thtoOutlet S=3.
S=2.0 61%
0%
6 Survey data indicates that the existing pipe is in
the same horizontal path as the proposed storm
725 725 drain pipe. A potential conflict with the jacking
and boring may exist. At a location between the
inlet and the outfall, the 15" Steel Pipe is connected
gati

42" MAIN_JefftoOutlet
42" MAIN_JefftoOutlet to an 18" CMP. Camera information indicates that
ti

a grade change may occur at this connection.


nage Mi

720 720 A vertical conflict cannot be determined at this time.


When the jacking and receiving pits are prepared,
the Contractor shall field locate the existing pipe
FEMA Storm water Drai

and determine at that time if a conflict is probable.


Horizontal adjustment of the 42" storm drain pipe
and the vaults may be required. Pipeline
715 715 grades and elevations MUST be maintained as
designed if a horizontal adjustment is required.
10+00 L4A 10+00 L3B
Adjustments shall be as approved by the Engineer
and shall be minimized as much as possible.
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 40’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW/DLJ 11/27/2012 6 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE LATERAL PROFILES JRS 12/03/2012
5A
NE

NE
EET

LROAD SPUR LI

N LI
NOTES:

STR

LROAD M AI
3 Removal of Sidewalk, Item 201.4.1.D.1

N
M AI
0 20 40 80 4 Removal of Curb, Item 201.4.1.E.1

64

RAI
Mainline Type "P" Surface Restoration

RAI
IN MAIN-DELSOL SW
20
STA = 10+00.00 L19A (Asphalt Roadway), Item 307.4.1.G.1
IN MAIN-DELSOL SW LATERAL 19B 1 SURVEY FEET 29’ 50’ (See "REMOVAL AND ASPHALT
N 1734374.080
STA = 10+06.75 L19A E 2306744.431 REPLACEMENT PLAN 2")
LATERAL 19D
N 1734371.518 Steel Casing Pipe Boring and Jacking, 54" (diameter),
IN MAIN-DEL NW
AM

21

6’
E 2306750.414 IN BRUNEEL_N Item 308.4.1.A.1
STA = 10+70.26 L19B
IN BRUNEEL_S MH BRUNEEL_CONN
11:48:44

22.1 SY, 44LF 64 N 1734420.127 STA = 10+0.00 L19D

15"
50 STA = 10+0.00 L19B STA = 140+83.34 30 Potable Water Main Crossing, Item SP-404B
E 2306757.602 N 1734636.891

00
5 78 75 74 72 4 3 N 1734614.970 50
N 1734489.268

12"
E 2306758.238

NE STA.142+00.
E 2306753.696 E 2306768.700 12" Storm Drain Pipe, Type S, Corrugated Polyethylene
64 61.8SY, 35LF 30’ 50
LATERAL 19A HY (CPP), Item 601.4.1.A.17A
FUTURE 42" D

NG 6
STORM DRAIN 3 4 72 74 64 18" Storm Drain Pipe, Type S, Corrugated Polyethylene
1 55 30 51
55 (CPP), Item 601.4.1.A.17B
55

SEE DRAW I
50 64 42" Storm Drain Pipe, Type S, Corrugated Polyethylene
55

25’
(CPP), Item 601.4.1.A.17F

6"
2"

69’
2"
50 58 Storm Drain Manhole, 72" Diameter, Item 602.4.1.E.1C
8"

M ATCH LI
63
DELSOL LANE MH DELSOL MAIN N 58
30 63 Storm Drain Conflict Manhole, Item SP-602.4A
STA = 138+70.39
8’ STUBOUT 58 21
N 1734394.820 Catch Basin - City of Lewiston Std (Type 1),
FOR FUTURE 20 64
6 55 E 2306761.339 Item SP-602.4B
29’
DECEMBER 2012

CONNECTION,
BOTTOM OF
CAP END 72 Standard 6-inch Vertical Curb & Gutter, Item 706.4.1.A.5
PUSH PIT 2 BORING/CASING
FUTURE 18"
LENGTH
STORM DRAIN 74 Concrete Sidewalks, Thickness 4", Item 706.4.1.E.1

3-PHASE UNDERG
WM
Pedestrian Ramp with Detectable Warning Domes,
Survey data indicates that the existing pipe is in 75

12"
7
FUTURE Item 706.4.1.H.1
FUTURE MH MAIN-DELSOL the same horizontal path as the proposed storm
IN MAIN-
MH MAIN- STA = 138+33.85 drain pipe. A potential conflict with the jacking LIMITS OF 78 Pedestrian Curb, Item SP-706.1A

12"
DELSOL SE
DELSOL E N 1734360.658 and boring may exist. At a location between the 3 EXCAVATION
E 2306763.426 inlet and the outfall, the 15" Steel Pipe is connected OF PUSH PIT Refer to Lateral Profile Sheets for the Pipe Lateral
1
2"

WM 8’ STUBOUT to a 24" CMP. Camera information indicates that Elevations and Profiles
FOR FUTURE a grade change may occur at this connection.
51 6 RETAIN & PROTECT
CONNECTION, A vertical conflict cannot be determined at this time. 54" Steel Casing Begins 30 feet South from Center Line

NE
EXISTING TRACK

NE
2

ROUND
CAP END When the jacking and receiving pits are prepared, of Rail Road Spur Line; Ends at Vault

N LI
AND BASE

LROAD SPUR LI
the Contractor shall field locate the existing pipe
FUTURE 18" Area disturbed by pit shall be restored to the existing
and determine at that time if a conflict is probable.

LROAD M AI
STORM DRAIN 3
condition. Pavement replacement shall be paid for
EET

Horizontal adjustment of the 42" storm drain pipe


as Item 307.4.1.G.1. Curbing, landscaping, irrigation
WM and the vaults may be required. Pipeline
water lines, fence and planting shall all be incidental to
STR

grades and elevations MUST be maintained as


the SP 308.4.
designed if a horizontal adjustment is required.
N

Adjustments shall be as approved by the Engineer


M AI

RAI
5 Refer to Drawing No. 9 for Pedestrian Ramp Detail.

RAI
and shall be minimized as much as possible.
\370-1105_hydr_019.dgn

Cap pipe prior to backfill. See "PIPE CAP DETAIL".


N)

N)
DELSOL_N

NW )
N)

Pipe cap shall be incidental to the pipe stubout.


36 (

M H BRUNEEL CONN
NW )

N)
S)

54 (
S)
65 (
E)
S)

96 (
36 (
DELSOL

07

NV OUT = 725.

59 (
45 (
34

NV OUT = 723.
1. Northings and Eastings are shown to the center of
07 (
65 (
97 (

STA = 138+68.
85

NV OUT = 725.

STA = 140+88.
N = 732.
N = 725.
STA = 138+33.

41

manhole and center of catch basin at face of curb

N = 723.
N = 734.
01
N = 730.
N = 725.
N = 734.

M = 739.
63

N-

M = 739.
M = 738.

745 745
N-

LEGEND
M H M AI
M H_M AI

NV I
NV I

NV I
NV I
EXISTING FIBER OPTIC
NV I
NV I
NV I

RI

RI
30’ FROMC
I
I
I

L EXISTING GAS
RI

I
I
I
l
SolOutfal

I
I
I
I

SPUR LINE EXISTING IRRIGATION


740 740
EXISTING OVERHEAD ELECTRICAL
EXISTING SANITARY SEWER
cs\13th_Del

EXISTING 15" STEEL PIPE 7 12" P BRUNEEL_N EXISTING STORM DRAIN


1 12" P MAIN-DELSOL_SW-2 1

00
12" P MAIN-DELSOL_NW-2 EXISTING TELEPHONE

NE STA.142+00.
735 735
EXISTING WATER
HYDRAULIC GRADE LINE
i
es\Hydraul

18" P MAIN-DELSOL_MH SE 54" STEEL CASING EXISTING GROUND

730 730
l
on\BE-370-1105\Sheet_Fi

M ATCH LI
BOTTOM OF T
DICH

725 725 USHI


GHWAY12

DELSOL_BORE MAI
NST
42I
NCH PDEL REE
SOL _MAI
N-BRUN
T

ET
L=28’ 42I
NCH

TRE
S=1.03% L=2 PDELSOLBORE
720 14’ 720

NS
13TH STREET
S=0.83 42I
NCH FST
% REE

SO
T
L=155’ N

DELSOL LANE
EET
STUBOUT STORM DRAIN PIPES

FER
gati

S=0
AND CAP ENDS
FOR REFERENCE ONLY .85%

JEF

STR
ti

GS
T

LN
REE
nage Mi

NCO
715 715

LI
Not Official Bid Document I
DA

15TH STREET
HO GS
ST TREE
RE T
FEMA Storm water Drai

ET

ET
I
DAH

16TH STREET
RE
O ST
REE
T

ST
Contact Horrocks Engineers

ER
LL
710 710

MI
138+00 139+00 140+00 141+00 142+00
T: (208) 463-4197
KEY PLAN
For Official Bid Documents
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 40’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 7 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE
DELSOL LANE PLAN AND PROFILE - 1 6
JRS 12/03/2012
LATERAL 19A LATERAL 19B

S)

N)
750 750

00 L19B

DELSOL_N
SE)

N)

88 (

36 (
S)
NW )

N)
DELSOL_SW

E)

S)
NW )
00 L19A

DELSOL_SW

65 (

60 (
N)
E)
S)

71
41 (

96 (
36 (
DELSOL
32 (

NV OUT = 735.

NV OUT = 725.
N BRUNEEL_S

42
GRATE = 739.
07 (
65 (
97 (

60 (
DEL_NW
32 (

STA = 10+00.
NV OUT = 725.

63
49

NV OUT = 733.
43

STA = 10+95.
78

26
NV OUT = 735.

N = 732.
N = 725.
AM

NV OUT = 735.
75

41
GRATE = 738.
GRATE = 738.

GRATE = 738.

STA = 10+23.

STA = 10+70.
N = 730.
N = 725.
N = 734.

N = 734.
STA = 10+00.

STA = 10+06.

M = 739.
N = 735.

63

N-
11:48:47

M = 738.
745 745

N-

M H M AI
N-

N-
M H_M AI
N-
N_M AI

NV I
NV I
N M AI
N M AI

NV I
NV I
NV I

NV I
NV I

RI
I

I
I
I
RI
I
I
I
I

I
I
I

I
I
740 740

FIELD VERIFY DEPTH OF WATER LINE FOR REFERENCE ONLY


ADJUST 12" STORM DRAIN VERTICALLY
735 TO AVOID 735
Not Official Bid Document
PBRUNEE
18" P MAIN-DELSOL_MH SE L_S
MAI
N-DEL 12I
NCH
SOL_SW
DECEMBER 2012

730
12I
NCH
L=5’ 42" P DELSOL MAIN MID N
L=6
S=1
8
.

86% 730
Contact Horrocks Engineers
S=2 42" DELSOL_BORE
.00%

T: (208) 463-4197
42" DELSOL_BORE
42" P DELSOL_MAIN-BRUN

725
PMAIN-DEL PMAI
725
For Official Bid Documents
SOL_SW- N-DEL
12I
NCH 2 SOL_
12I
NCH NW-
2
L=13’ L=21’
S=2.73% S=3.
00%
720 720

715 715

10+00 L19A 10+00 L19B


\370-1105_hydr_019A.dgn

LATERAL 19D

750 750
N)
SE)

NW )
M H BRUNEEL CONN

LEGEND
00 L19D

54 (
S)
86 (

59 (
45 (
NV OUT = 723.
74
69
NV OUT = 734.
N BRUNEEL_N

STA = 10+24.
GRATE = 738.
l

N = 723.
N = 734.
SolOutfal

STA = 10+00.

01

EXISTING FIBER OPTIC


M = 739.

745 745

EXISTING GAS
NV I
NV I
cs\13th_Del

RI
I
I
I
I

EXISTING SANITARY SEWER


740 740

EXISTING TELEPHONE
i
es\Hydraul

EXISTING WATER
735 735

HYDRAULIC GRADE LINE


l
on\BE-370-1105\Sheet_Fi

PBRUNEE
L_N
12I
NCH EXISTING GROUND
L=21’
730 S=2 730
.00%

42" P DELSOL_MAIN-BRUN

725 725
42" P DELSOL BORE
ti
nage Mi gati

720 720
FEMA Storm water Drai

715 715

10+00 L19D
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 40’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW/DLJ 11/27/2012 8 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE
LATERAL PROFILES 6A
JRS 12/03/2012
LROAD
NE

NE

N
GHW AY 12/
LROAD SPUR LI

N LI
83 NOTES:

KE BYPASS
M AI
RAI
0 20 40 80 4 Removal of Curb, Item 201.4.1.E.1

US HI
7 Seedbed Preparation, Item 206.4.1.A.1

DI
SURVEY FEET

RAI
8 Seeding, Item 206.4.1.B.1

VER
RETAIN & PROTECT
1 83

RI
EXISTING RAIL LINE 9 Mulching, Item 206.4.1.C.1
AND SECTION

W ATER
11:48:58 AM

100’ 10 Mulch Anchoring (tack), Item 206.4.1.E.1

EXCAVATION LIMITS
SEE DETAILS FOR 12 Fertilizing, Item 206.4.1.G.1
FROM 1.5:1 SLOPE

CLEAR
3 ADDITIONAL
INFORMATION
13 Loose Riprap, Item 206.4.1.H.3
84
TEMPORARY 83
4 72 76 LF

00
14 Riprap/Erosion Control Geotextile, Item 2050.4.1.B.1
SHORING

NE STA.142+00.
The Main Railroad Mainline Track shall Remain Open
71 1
23 61 at all Times 15 Permanent Sheet Piling, Item SP-200A
22

NG 5
55 55 EXISTING
DELSOL LANE 54" Steel Casing Begins 30 feet South from Center Steel Casing Pipe Boring and Jacking, 54" (diameter),
2 21
OUTLET Line of Rail Road Spur Line; Ends at Vault Item SP-308.4

SEE DRAW I

67’
Area disturbed by pit shall be restored to the existing

65’
3 22 Temporary Shoring, Item SP-308A
condition. Pavement replacement shall be paid for
as Item 307.4.1.G.1. Curbing, landscaping, irrigation
23 Flow Fill, Item SP-308B
water lines, fence and planting shall all be incidental to
M ATCH LI

20’
DECEMBER 2012

the SP 308.4.
24 Replace Railroad Base, Item SP-308E
21 Survey data indicates that the existing pipe is in
71 4 42" Storm Drain Pipe, Type S, Corrugated Polyethylene
7 8 9 the same horizontal path as the proposed storm 55
47’ 15 (27 LF) (324 SF) (CPP), Item 601.4.1.A.17F
drain pipe. A potential conflict with the jacking
10 12 and boring may exist. At a location between the 19"X30" Elliptical, Storm Drain Pipe, Class III, RCP,
BORING/CASING 61
13 14 inlet and the outfall, the 15" Steel Pipe is connected Item 601.4.1.A.1A (5 Pipe Array)
LENGTH
2 MH DELSOL BORE-UP to a 24" CMP. Camera information indicates that Vault, width 48", height 60", length 20’, Item 704.4.1.C.1B
76 71
a grade change may occur at this connection.

3-PHASE UNDERG
STA = 142+50.37 (Refer to DelSol Lane Outlet Detail Sheet)
N 1734774.660 A vertical conflict cannot be determined at this time.
When the jacking and receiving pits are prepared, 72 Standard 6-inch Vertical Curb & Gutter, Item 706.4.1.A.5
E 2306771.479
ACOE 4 72 50 LF LIMITS OF the Contractor shall field locate the existing pipe
Concrete Headwall (42"), Item SP-704A
BOUNDARY EXCAVATION FOR and determine at that time if a conflict is probable. 76
(Refer to Headwall Detail Sheet)
NE

NE

MH DELSOL-12 PL SINGLE TRENCH BOX Horizontal adjustment of the 42" storm drain pipe
LROAD SPUR LI

N LI

STA = 143+21.30 and the vaults may be required. Pipeline 83 Biofilter Bags, Item 1003.4.1.B.1

GHW AY 12/
N 1734845.559 grades and elevations MUST be maintained as
LROAD M AI

PERMANENT
E 2306772.738 designed if a horizontal adjustment is required.
KE BYPASS
STORMDRAIN 84 Silt Fence, Item 1001.4.A.1
Adjustments shall be as approved by the Engineer
ROUND

CLEARWATER PAPER EASEMENT


and shall be minimized as much as possible.
EFFLUENT LINE
84
US HI

1. Northings and Eastings are shown to the center of


RAI

RAI

manhole and center of catch basin at face of curb


DI
\370-1105_hydr_020.dgn

UP

N)
N)
N)
N)
N)
M H_DELSOL_BORE-

745 745

N)
LEGEND
14 (
14 (
14 (
14 (
14 (
S)

48 (
12_PL

S)
S)
S)
S)
S)
22 (
06

NV OUT = 722.
NV OUT = 722.
NV OUT = 722.
NV OUT = 722.
NV OUT = 722.

EXISTING FIBER OPTIC

57 (
57 (
57 (
57 (
57 (
98

NV OUT = 721.
STA = 142+48.

STA = 143+18.
N = 722.

EXISTING GAS
72

M H_DELSOL-

N = 721.
N = 721.
N = 721.
N = 721.
N = 721.
l

21
SolOutfal

M = 734.

EXISTING IRRIGATION
M = 734.

740 740
EXISTING OVERHEAD ELECTRICAL
NV I

NV I
NV I
NV I
NV I
NV I
EXISTING SANITARY SEWER
FOR REFERENCE ONLY
RI
cs\13th_Del

RI
I
I
I
I
I
I

EXISTING STORM DRAIN


I
I
I
I
I
I
00

EXISTING TELEPHONE
EXISTING CLEARWATER
NE STA.142+00.

735 735
EXISTING 24" CMP 4
PAPER EFFLUENT LINE
Not Official Bid Document EXISTING WATER
HYDRAULIC GRADE LINE
i
es\Hydraul

EXISTING GROUND

Concrete
Contact Horrocks Engineers
730 730

2’
Headwall
54" STEEL CASING
l

T: (208) 463-4197
on\BE-370-1105\Sheet_Fi

M ATCH LI

INV.
ELEV. BOTTOM OF T
DICH

721.08
725
For Official Bid Documents 725 USHI
GHWAY12

10’
MAI
NST
REE
T

ET
TRE
2’
720 720

NS
P_

13TH STREET
ARRAYOF5PI PES FST
REE

SO
19"
x DELSOL_OUTLET
T
30"ELLI
PTI
CALPI N

DELSOL LANE
PES

EET
FER
42I
gati

L=6 7’ NCH

JEF

STR
S=0 L=47’
.
85%
ti

GS
S=0 PERMANENT T

LN
REE
.85%
nage Mi

NCO
SHEET PILING
715 715

LI
I
DA

15TH STREET
HO GS
ST TREE
RE T
FEMA Storm water Drai

ET

ET
I
DAH

16TH STREET
RE
O ST
REE
T

ST
ER
LL
710 710

MI
142+00 143+00 144+00 145+00 146+00

KEY PLAN
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 40’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 9 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE
DELSOL LANE PLAN AND PROFILE - 2 7
JRS 12/03/2012
MANHOLE FRAME, COVER
8’-0"
AND CONCRETE COLLAR
RIM ELEV., SEE (PER ISPWC STANDARD
4’-0" 4’-0" PROFILE SHEET DRAWINGS SD-616, SD-617)

CONNECT TO
MANHOLE FRAME, COVER EXISTING 15" DIA.

N.
AND CONCRETE COLLAR EXISTING

8"
CLAY PIPE AT

MI
(PER ISPWC STANDARD 15" DIA. CLAY PIPE
NEAREST JOINT
DRAWINGS SD-616, SD-617)

FY BURY DEPTH
15" DIA. PVC
11:49:01 AM

GRAVITY
SEWER PIPE MANHOLE STEPS

0"
(PER ISPWC
24" DIA. STEEL PIPE

-
1’
STANDARD
CASING (PROTECT IN
PRECAST CONCRETE DRAWING SD-509)
PLACE) (SEE NOTE 6)
VAULT, BASE, AND

)
TYP.
ELD VERI

0"
COVER GROUT AROUND REDWOOD BLOCK SPACER

NG

-
1’
PIPE (TYP.) (SEE (TYP. AS REQUIRED TO SPACE

OR TO ORDERI

(
NOTES 2 AND 7) THE 15" DIA. PVC PIPE
42" DIA. RCP 42" DIA. RCP 42" DIA. UNIFORMLY INSIDE THE

FI
STORM STEEL PIPE CASING)
0"

PE SUPPORT
DRAIN PIPE 42" DIA. STORM DRAIN PIPE
-
4’

CONCRETE

FY PRI
DECEMBER 2012

PI

ELD VERI
0"

0"
A A
-

-
8’

1’

FI

SEE NOTE 8)
15" DIA. PVC
GRAVITY

A"
SEWER PIPE

"
-
4’0"

NK GROUT
M ETER
INV. ELEV. (SEE
24" DIA. STEEL PIPE PROFILE SHEET) INV. ELEV. (SEE

DE PERI
CASING (PROTECT IN PROFILE SHEET)
PLACE) (SEE NOTE 6)

SHRI
_001.dgn

1/4" x 6" STEEL STRAP CONCRETE PRECAST CONCRETE


PIPE SUPPORT

NSI
6"NON-
SECURED WITH BASE

15" PVC GRAVITY 1/2" x 6" ANCHOR BOLTS

AT I
NON-SHRINK GROUT
CONNECT TO
\370-1105_hydtl

SEWER PIPE TROWEL TO FLOW LINE


EXISTING 15" DIA.
OF 42" DIA. RCP
CLAY PIPE AT
NEAREST JOINT SECTION A-A
EXISTING
15" DIA. CLAY PIPE
l
SolOutfal

CONFLICT MANHOLE PLAN NOTES:


1. CONFLICT MANHOLE SHALL CONFORM TO SECTION 602 - STORM
cs\13th_Del

DRAIN INLETS, CATCH BASINS, MANHOLES, AND GRAVITY IRRIGATION


STRUCTURES OF THE CURRENT IDAHO STANDARDS FOR PUBLIC
WORKS CONTRACTS. ALL REINFORCEMENT SHALL HAVE A
MINIMUM CONCRETE COVER OF 2" AND/OR 3" IF CAST AGAINST
EARTH.
i
es\Hydraul

2. ALL CONNECTIONS AND BROKEN AREAS SHALL BE GROUTED


SMOOTH TO FORM A WATER TIGHT MANHOLE. CONSTRUCTION
FOR REFERENCE ONLY JOINTS SHALL CONFORM TO AASHTO AND ASTM REQUIREMENTS.
l
on\BE-370-1105\Sheet_Fi

3. THE MANHOLE LIDS SHALL BE DESIGNED FOR AASHTO HS-25

Not Official Bid Document (ENGLISH MEASUREMENT) LIVE LOADS.

4. MANHOLE STEP SHALL CONFORM TO IDAHO STANDARDS FOR


PUBLIC WORKS CONSTRUCTION, STANDARD DRAWING SD-509
Contact Horrocks Engineers AND SECTION 504.06 PLASTIC COATED MANHOLE STEPS.

5. STANDARD DRAWINGS SD-616 AND SD-617 SHALL ACCOMPANY

T: (208) 463-4197 THIS DRAWING.

6. GRAVITY SEWER PIPE SHALL MEET THE REQUIREMENTS OF


ISPWC SECTION 500 AND IS INCIDENTAL TO THE CONFLICT
gati

For Official Bid Documents MANHOLE.


ti
nage Mi

7. KNOCKOUTS IN MANHOLE WALLS SHALL BE A MINIMUM 3" CLEAR


FROM ALL SIDES OF THE 42" DIA. RCP PIPES AND THE 24" DIA,
STEEL PIPE CASING.
FEMA Storm water Drai

8. THE HEIGHT OF THE CONCRETE PIPE SUPPORT, DIMENSION "A",


SHALL BE FIELD VERIFIED. THE ANTICIPATED HEIGHT FOR THE
CONFLICT MANHOLE AT MAIN STREET AND DEL SOL LANE IS 2’-3".
THE ANTICIPATED HEIGHT FOR THE CONFLICT MANHOLE AT MAIN
STREET AND 13TH STREET IS 1’-7".
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
3/8" = 1’-0" Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW/TLH 11/27/2012 10 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
CONFLICT MANHOLE DETAILS 8
JRS 12/03/2012
NOTES:

Potable Water Service Conflict Pedestrian Ramp Detail Standard 6-inch Vertical Curb & Gutter
72 Item 706.4.1.A.5

Type A (See Drawing No. 6)

1
5" Concrete Sidewalks, Thickness 4"
TOP OF GROUND
74 Item 706.4.1.E.1
(See Drawing No. 6)
STORM DRAIN
Pedestrian Ramp w/Detectable Warning
AM

75 Domes, Item 706.4.1.H.1


11:49:04

(See Drawing No. 6)


Pedestrian Curb, Item SP-706.1A
MAI 78
EXISTING WATER SERVICE NST (See Drawing No. 6)
REE
T
MATCH EXISTING SERVICE
LINE SIZE AND MATERIAL R= 20.
00
T=27.
39
PIN:1734370.
657

N.
11 Retain and Protect Hydrant

18"
E:2306760.
932

MI
CC N:1734354.
380
E:2306740.
887

o o 72
22 OR 45 BEND
DECEMBER 2012

10’ 11

8"
2"
MATCHEXI
STI
NG CURB
THRUST BLOCKING PER
DWG. 4-4 OR APPROVED
JOINT RESTRAINT (SEE
NOTES 3, 4, & 5)
Type B
TOP OF GROUND
75

N.
MATCH EXISTING SERVICE

4’M I
LINE SIZE AND MATERIAL MATCHEXI
STI
NG SI
DEWALK
o o 6.
00
22 OR 45 BEND ’
7.00’ 6"

YD
THRUST BLOCKING PER
DWG. 4-4 OR APPROVED 10’ 74

H
JOINT RESTRAINT (SEE N. BEGI
NPEDESTRIANCURB 5.25’
18"

N:1734366.322
MI
NOTES 3, 4, & 5)
E:2306742.
591 7.00’
N:1734365.
831 78
E:2306744.
948
_002.dgn

EXISTING WATER SERVICE


N:1734362.
906 3.
75’
\370-1105_hydtl

E:2306751.
199
STORM DRAIN MATCHEXI ST I
NG
RADIUS 15.0FT
N:1734356.
408

38’
FOR REFERENCE ONLY

DELSOL LANE
E:2306755.
934

9.
Type C ENDPEDESTRIANCURB
l
SolOutfal

N:1734354.
431
EXISTING WATER SERVICE
TOP OF GROUND
E:2306755.
892 Not Official Bid Document
10’ N
cs\13th_Del

MATCHEXI
STI
NG SI
DEWALK
Contact Horrocks Engineers
N.
18"

MATCHEXI
STI
NG CURB
T: (208) 463-4197
MI
i
es\Hydraul

MATCH EXISTING SERVICE For Official Bid Documents


LINE SIZE AND MATERIAL
l
on\BE-370-1105\Sheet_Fi

STORM DRAIN

Notes
ti
nage Mi gati

1. Field verify location and type of material prior to disrupting water or sewer service
2. Installed pipe and fittings shall be of a type compatible with existing pipe material
3. Approved joint restraints for mechanical joints 12" and smaller include GripRing (Romac Industries), MJ Field Lok (US Pipe), and AllGrip/PVCGrip (Star Pipe)
FEMA Storm water Drai

ring-type gripping restraints or equivalent.


4. Approved joint restraints for mechanical joints larger than 12" include RomaGrip (Romac Industries), Megalug (EBAA Iron), Stargrip (Star Pipe), and Uniflange
series 1400/1500 (Ford Meter box) radial-wedge type mechanical joint restraints or equivalent.
5. All joint restraints shall be of a type compatible with the pipe material.
6. If storm drain can be installed without damaging water or sewer service lines for Type C crossings. The crossing will not include replacing water or sewer service pipe.
7. If 18" of clearance is not practical, storm drain may be constructed of water class pipe and pressure tested for water-tightness for 10 ft either side of crossing.
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
NTS Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT TLH 11/27/2012 11 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS NTS DRAWING IS NOT TO SCALE
SERVICE CONFLICT AND PEDESTRIAN RAMP DETAILS 9
JRS 12/03/2012
1
SURFACE REPAIR WIDTH
CROSS-HATCHED AREAS ON PLANS
Cut Asphalt in Neat Line REMOVAL OF CURB, REMOVAL OF
GUTTER, & REMOVAL OF SIDEWALK BACK OF
12 (ITEMS 201.4.1.D.1, 201.4.1.E.1, ) SIDEWALK
LEGEND:

Existing Asphalt 1 LOCAL CUT BACK, ONLY IF REQUIRED.


Existing Base
NEAREST EXISTING NEAREST EXISTING
2 UPPER COMPACTION ZONE

DTH
CONSTRUCTION JOINT CONSTRUCTION JOINT

DEWALK WI
AM

13
5 3 LOWER COMPACTION ZONE
11:49:07

SUBGRADE OR 4 IDENTIFYING TAPE PER DWG No 1-8

NG SI
NATURAL GROUND
0"

5
-

TRENCH BACK SLOPE PER O.S.H.A. OR SUITABLE SHORING

STI
4’

MATCH EXI
.
NG

VERTICLE WALLS 6 TRENCH BACKFILL PER SECTION 306


THOUT SHORI

ALLOWED WITH
PROPER SHORING
OR LESS THAN 5’ 7
6 VERTICAL TRENCH WALLS SHORING PER O.S.H.A.

2
8 PIPE BEDDING PER SECTION - 305
.W I

FOUNDATION STABILIZATION MAY VARY PER SOIL TYPE AND


ench Depth

9
DECEMBER 2012

3 CALLOUT POINT
.
0"M AX.

es Per

STABILITY (PER SECTION - 304)


4
7
FACE OF
i

10 TRACE WIRE
Var
-
5’

CURB
Tr

11 UNDISTURBED SOIL (TYP)


N.

10
8"

12 4" CLASS I PLANT MIX PAVEMENT


MI

8
es Per
ze

CATCH BASIN LIP OF


pe Si

GRATE GUTTER
13 12" TYPE I CRUSHED AGGREGATE FOR BASE
Vari
Pi

CURB, GUTTER AND SIDEWALK REMOVAL AND REPAIR


AT CATCH BASIN
NOTE B NOTES (ITEMS 201.4.1.D.1, 201.4.1.E.1,
NOTES: 706.4.1.A.6, 706.4.1.E.1 AND 706.4.1.H.1)
9 A TRENCH EXCAVATION PER SECTION - 301
11
B TYPE A-1 PIPE BEDDING PER SECTION - 305 1. CROSS-HATCHED AREAS AS SHOWN ON THE DETAIL AND IN THE PLANS INDICATE AREA IN SY OR LENGTH IN LF OF CURB AND GUTTER AND SIDEWALK TO BE REMOVED. REMOVAL IS PAID
FOR AS REMOVAL OF SIDEWALK, ITEM 201.4.1.D.1 AND REMOVAL OF CURB, ITEM 201.4.1.E.1.
C BACKFILL AND COMPACTION PER SECTION - 306

D TACK ALL COLD JOINTS W/ EMULSION WHICH HAS 2. CROSS HATCHED AREAS (WITH NO PATTERN CONCRETE) SHOWN TO HAVE CURB AND GUTTER AND SIDEWALK CONSTRUCTED AS SHOWN ON THE PLANS AND SHALL BE PAID
FOR AS STANDARD 6-INCH VERTICAL CURB AND GUTTER, ITEM 706.4.1.A.5 AND CONCRETE SIDEWALKS, THICKNESS 4", ITEM 706.4.1.E.1. PLACEMENT AND COMPACTION OF BASE DISTURBED
_003.dgn

BEEN BROKEN PRIOR TO PATCHING


DURING REMOVAL OF CURB, GUTTER AND SIDEWALK SHALL BE INCIDENTAL TO ITEMS 706.4.1.E.1 AND 706.4.1.A.5.
E ASPHALT PAVEMENT PER SECTION 810
OUTSIDE DIA. OF
\370-1105_hydtl

F CRUSHED AGGREGATE FOR BASE PER SECTION 802


PIPE PLUS 2’-0"

TYPICAL TENCH DETAIL


i
es\Hydraulcs\13th_Del l
SolOutfal

RETRIEVAL STRAP

FOR REFERENCE ONLY

Not Official Bid Document


l
on\BE-370-1105\Sheet_Fi

Contact Horrocks Engineers

T: (208) 463-4197

For Official Bid Documents


gati

OVERFLOW
(PEAK STORM)
ti
nage Mi
FEMA Storm water Drai

SEDIMENT ACCUMULATION

GEOTEXTILE FABRIC

INLET PROTECTION
(Item 1006.4.1.C.1)
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
3/8" = 1’-0" Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW/TLH 11/27/2012 12 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
DETAILS 10
JRS 12/03/2012
w o rk
END
W1-4R
G20-2
36"x36"

ro a d
36"x18"

W20-1
36"x36"

A H EA D
W O RK
RO A D
W1-4R
100’ 125’ 36"x36"
11:49:09 AM

CHANNELIZING
CONE (TYP.)

30’ 125’ 45’ 100’ 100’ COVER END OF PIPE


(TYP.) WITH 3/8" DIAMOND
(SHIFTING (SHLDR
PLATE STEEL
TAPER) TAPER)

3/8" DIAMOND
PLATE STEEL
MAIN STREET

COMPACTED
3/4" AGGREGATE

AM ETER + 4"
DECEMBER 2012

TYPE III
TYPE II WORK BARRICADE
100’ 100’ 45’ 125’ BARRICADE ZONE 100’ 125’ 100’
TYPE II
(SHLDR (SHIFTING BARRICADE
TAPER) TAPER)

OUTER DI
R11-2 road
AHEAD

DEWALK
48"x30"

DEW A LK CLOSED
WORK
ROAD

closed
SI

CLOSED
CLOSED

road work

C R O S S H ER E
DEWALK

A HEA D
R9-9 R9-9
W20-1
24"x12" 24"x12"

END
36"x36"

SI

SI

)
TYP.
4"
R9-11
24"x18"

(
W1-4L
COMPACTED
36"x36" G20-2
NOTE: 3/4" AGGREGATE
CONTRACTOR SHALL MAINTAIN ONE LANE OF TRAFFIC 36"x18" 4"
IN EACH DIRECTION AT ALL TIMES ON MAIN STREET (TYP.)
EXCEPT WHEN PIPE CROSSINGS AT DELSOL LANE SIDE VIEW FRONT SECTION
AND 13TH STREET ARE BEING INSTALLED.

PIPE CAP DETAIL


_004.dgn

TYPE III
BARRICADE
l
SolOutfal\370-1105_hydtl

road CLOSED
R11-4
AHEAD
60"x30"
LOCAL TRAFFIC ONLY
cs\13th_Del

TYPICAL MAIN STREET TRAFFIC CONTROL


i

FOR REFERENCE ONLY


es\Hydraul

GENERAL NOTES:
Not Official Bid Document
l
on\BE-370-1105\Sheet_Fi

1. IF THE TRAFFIC CONTROL PLAN AS SHOWN DOES NOT CONFORM TO 7. ALLOW ACCESS TO PROPERTY OWNERS AT ALL TIMES.
THE CONTRACTOR’S METHOD OF OPERATION, THE CONTRACTOR
SHALL SUBMIT NEW TRAFFIC CONTROL PLANS TO THE ENGINEER
FOR APPROVAL PRIOR TO BEGINNING CONSTRUCTION.
8. MAINTAIN ONE TRAVEL LANE IN EACH DIRECTION DURING
NON-WORKING HOURS.
Contact Horrocks Engineers
2. ALL REQUIRED CONSTUCTION SIGNING AND TUBULAR MARKERS 9. THE CONTRACTOR SHALL HAVE FLAGGING OPERATIONS AT ONE
SHALL BE IN PLACE PRIOR TO ANY DIVERSION OF TRAFFIC WITHIN INTERSECTION AT A TIME. FLAGGING OF TWO OR MORE T: (208) 463-4197
THE PROJECT. INTERSECTIONS AT A TIME WILL NOT BE ALLOWED UNLESS
OTHERWISE APPROVED BY THE ENGINEER. NO LANE CLOSURES
3. ADDITIONAL SIGNING MAY BE REQUIRED AS DIRECTED BY THE
ENGINEER.
BETWEEN THE HOURS OF 7:00 AM TO 9:00 AM AND 4:00 PM TO 6:00 PM
WILL BE ALLOWED WITHOUT WRITTEN APPROVAL.
For Official Bid Documents
gati

4. ALL CONSTRUCTION WARNING SIGNS SHALL HAVE TWO WARNING 10.STREET CLOSURES WILL BE ALLOWED FOR A LENGTH OF 1 BLOCK
FLAGS. A BATTERY OPERATED FLASHING WARNING LIGHT SHALL BE INCREMENTS. ADJACENT STREET CLOSURES WILL NOT BE ALLOWED.
ti
nage Mi

IN PLACE DURING HOURS OF DARKNESS. THE CONTRACTOR SHALL


NOT IMPEDE TRAFFIC DURING NON-WORKING HOURS WITHOUT 11.THE CONTRACTOR MAY WORK IN THE AREAS NORTH OF MAIN STREET
WRITTEN APPROVAL FROM THE ENGINEER. 24-HOURS PER DAY.
FEMA Storm water Drai

5. WORK ZONE SIGNS SHALL BE MOUNTED AT A MINIMUM 5’ (FOOT)


MOUNTING HEIGHT, MEASURED TO THE BOTTOM OF THE SIGN.
SIGNS AND SIGN SUPPORTS SHALL MEET THE NCHRP-350 CRASH
WORTHINESS STANDARD.

6. FLAGGERS SHALL BE USED AS DIRECTED DURING CONSTRUCTION


DAYLIGHT HOURS.
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
NTS
5700 East Franklin Rd.
Suite 160
Nampa, ID 83687
(208) 463-4197

Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 13 OF 21


IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE TRAFFIC CONTROL DETAILS AND GENERAL NOTES JRS 12/03/2012
11
GHW AY 12/
KE BYPASS

N
PERMANENT POINT TABLE
STORMDRAIN

US HI
EASEMENT
0 10 20 40
POINT DESCRIPTION NORTHING EASTING

DI
A CORNER OF VAULT 1734882.85 2305605.50
1
75’ SURVEY FEET B CORNER OF VAULT 1734888.04 2305606.70

C CORNER OF VAULT 1734883.56 2305626.13


STORM DRAIN STORM DRAIN D CORNER OF VAULT 1734878.36 2305624.93
11:49:21 AM

VAULT VAULT
LIMITS OF
E CORNER OF VAULT 1734932.35 2305616.82
EXCAVATION FOR F CORNER OF VAULT 1734937.55 2305618.02
SINGLE TRENCH BOX EXISTING
E G CORNER OF VAULT 1734933.06 2305637.45
TEMPORARY B 13TH STREET
SHORING OUTLET
A B 42" STORM DRAIN PIPE H CORNER OF VAULT 1734927.87 2305636.25
6 F
1 1 PIPE INVERT IN 1734886.80 2305609.11
A 2
7 2 PIPE INVERT IN 1734885.98 2305612.69
3
3 PIPE INVERT IN 1734885.15 2305616.26

4 PIPE INVERT IN 1734884.33 2305619.83

5 PIPE INVERT IN 1734883.50 2305623.40


1
6 PIPE INVERT OUT 1734932.41 2305619.55
DECEMBER 2012

55’

20’
7 PIPE INVERT OUT 1734931.58 2305623.12

8 PIPE INVERT OUT 1734930.76 2305626.69

9 PIPE INVERT OUT 1734929.93 2305630.27


PERMANENT 10 PIPE INVERT OUT 1734929.11 2305633.84
SHEET PILING
4 8 (30 LF) (360 SF)

D 9 G
5
10
C MH 13AR DWN CONCRETE HEADWALL
A’ B’ STA = 42+97.93
54" STEEL
CASING
H
N 1734932.709 FOR REFERENCE ONLY
E 2305627.139

Not Official Bid Document


ARRAY OF 5 - 22"x34"
MH 13AR UP ELLIPTICAL PIPES Contact Horrocks Engineers
STA = 42+47.14
_005.dgn

N 1734883.203
E 2305615.813
T: (208) 463-4197
NE

GHW AY 12/
N LI
\370-1105_hydtl

KE BYPASS

RETAIN & PROTECT;


For Official Bid Documents
LROAD M AI

RAIL TO REMAIN OPEN


AT ALL TIMES
US HI
DI

CLEARWATER PAPER
RAI

EFFLUENT LINE
ACOE BOUNDARY
l
SolOutfal
cs\13th_Del

VAULT & PIPE DETAIL PIPE ARRAY DETAIL


N.T.S. N.T.S.

EXISTING GROUND EXISTING GROUND


i
es\Hydraul

NOTES:
l
on\BE-370-1105\Sheet_Fi

CLEARWATER PAPER
1. SEE "13TH STREET OUTLET PLAN AND PROFILE" FOR ADDITIONAL
EFFLUENT LINE
INFORMATION

CITY OF
LIMIT DISTURBANCE OF US 12/DIKE BYPASS TO THE MAXIMUM
1 LEWISTON 42" STORM DRAIN PIPE
AS SHOWN ON THE PLANS. PATCHING AND REPAIR SHALL BE
STANDARD STORM DRAIN VAULT
PAID FOR AS ITEM 307.4.1.F.1, MAIN LINE TYPE "P" SURFACE
MANHOLE
gati

RESTORATION (ASPHALT ROADWAY). PAVING OF US-12/ 22"X34" ELLIPTICAL


AND COLLAR (TYP) LIMITS OF
DIKE BYPASS ROAD SHALL MEET ITD STANDARD SPECIFICATIONS. STORM DRAIN PIPE LIMITS OF
ti

EVENLY SPACED PERMANENT


nage Mi

PERMANENT
EASEMENT
EASEMENT

FLOW FILL 22"X34" ELLIPTICAL


FEMA Storm water Drai

0.25’ (Typ)
VAULT BEDDING STORM DRAIN PIPE
0.25’ (Typ)
PIPE BEDDING
0.96’ (Typ)
A 0.29’ (Typ) A’ B B’
20.00’

ALONG CENTERLINE OF CLEARWATER EFFLUENT LINE


H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160

1"=20’
Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT DLJ 11/27/2012 14 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
CHECKED
REV DATE BY DESCRIPTION MEASURE 1" THEN US 12 CROSSING DETAILS (13TH ST)
REVISIONS DRAWING IS NOT TO SCALE 12
N/A JRS 12/03/2012
1
100’
EXCAVATION LIMITS
POINT TABLE

N
FROM 1.5:1 SLOPE

POINT DESCRIPTION NORTHING EASTING


0 10 20 40
A CORNER OF VAULT 1734771.99 2306761.51
STORM DRAIN STORM DRAIN
TEMPORARY SHORING VAULT VAULT B CORNER OF VAULT 1734777.33 2306761.51
SURVEY FEET
E C CORNER OF VAULT 1734777.33 2306781.45
B
D CORNER OF VAULT 1734771.99 2306781.45
11:49:32 AM

A B
6 F
42" STORM E CORNER OF VAULT 1734842.89 2306762.77
1
DRAIN PIPE
A F CORNER OF VAULT 1734848.23 2306762.77
2
7 42" STORM EXISTING
3 DRAIN PIPE 13TH STREET G CORNER OF VAULT 1734848.23 2306782.71
OUTLET
H CORNER OF VAULT 1734842.89 2306782.71

1 PIPE INVERT IN 1734776.66 2306764.18


1
2 PIPE INVERT IN 1734776.66 2306767.85

67’
65’
3 PIPE INVERT IN 1734776.66 2306771.51

4 PIPE INVERT IN 1734776.66 2306775.18

5 PIPE INVERT IN 1734776.66 2306778.85

20’
6 PIPE INVERT OUT 1734843.56 2306765.37
DECEMBER 2012

7 PIPE INVERT OUT 1734843.56 2306769.04


8
4 PERMANENT 8 PIPE INVERT OUT 1734843.56 2306772.74
D G
9 SHEET PILING
5 9 PIPE INVERT OUT 1734843.56 2306776.37
(27 LF) (324 SF)
C 10 PIPE INVERT OUT 1734843.56 2306780.04
A’ B’
10 H
54" STEEL CONCRETE HEADWALL
PERMANENT
CASING
STORMDRAIN ARRAY OF 5 - 19"x30"
EASEMENT ELLIPTICAL PIPES

FOR REFERENCE ONLY


LIMITS OF
MH DELSOL BORE-UP
3-PHASE UNDERG

EXCAVATION FOR
STA = 142+50.37
N 1734774.660
MH DELSOL-12 PL
STA = 143+21.30
SINGLE TRENCH BOX Not Official Bid Document
RETAIN & PROTECT; N 1734845.559
E 2306771.479
RAIL TO REMAIN OPEN E 2306772.738
AT ALL TIMES Contact Horrocks Engineers
_006.dgn

ACOE
CLEARWATER PAPER
T: (208) 463-4197
BOUNDARY
ROUND

EFFLUENT LINE
\370-1105_hydtl

NE

GHW AY 12/
N LI

For Official Bid Documents


KE BYPASS
LROAD M AI

US HI
DI
l
SolOutfal

RAI
cs\13th_Del

VAULT & PIPE DETAIL PIPE ARRAY DETAIL


N.T.S. N.T.S.
i
es\Hydraul

EXISTING GROUND EXISTING GROUND


l
on\BE-370-1105\Sheet_Fi

NOTES:

CLEARWATER PAPER
1. SEE "DELSOL LANE PLAN AND PROFILE" FOR ADDITIONAL EFFLUENT LINE
STORM DRAIN VAULT LIMITS OF (48" HDPE )
INFORMATION
PERMANENT
EASEMENT

CITY OF
LIMIT DISTURBANCE OF US 12/DIKE BYPASS TO THE MAXIMUM
1 LEWISTON
gati

AS SHOWN ON THE PLANS. PATCHING AND REPAIR SHALL BE 42" STORM DRAIN PIPE
STANDARD
PAID FOR AS ITEM 307.4.1.F.1, MAIN LINE TYPE "P" SURFACE
ti

MANHOLE 19"X30" ELLIPTICAL


nage Mi

RESTORATION (ASPHALT ROADWAY). PAVING OF US-12/


AND COLLAR (TYP) STORM DRAIN PIPE (TYP)
DIKE BYPASS ROAD SHALL MEET ITD STANDARD SPECIFICATIONS.
EVENLY SPACED LIMITS OF
STORM DRAIN VAULT
FLOW FILL PERMANENT
FEMA Storm water Drai

EASEMENT

0.63’ (Typ) 30"X19" ELLIPTICAL


VAULT BEDDING PIPE BEDDING
0.63’ (Typ) STORM DRAIN PIPE

A 0.48’ (Typ) A’ B 1.15’ (Typ) B’


20.00’

ALONG CENTERLINE OF CLEARWATER EFFLUENT LINE


H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1"=20’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT DLJ 11/27/2012 15 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
US 12 CROSSING DETAILS (DELSOL LN) JRS 12/03/2012
13
3"

" NC MACHINE BOLT


3"
6"+D/24 W/NUT AND LOCK NUT
A B
B-4
11:49:35 AM

SEE B-4 DETAIL


"
SEE BEVEL DETAIL

8"+D/12
A-1"
6" 2"
(2) B-4
BARS
"

H
7"

D
B-4 DETAIL

9"
9"
1:1 BEVEL (SEE NOTE 42" STORM
KEY
DECEMBER 2012

NO. 5 & BEVEL DETAIL) 42" STORM DRAI


N PI
PE
DRAIN PIPE

-0"
2’
A B 6" 6"

1:1 BEVEL (SEE NOTE


ELEVATION SECTION A-A SECTION B-B NO. 5 & BEVEL DETAIL)
_007.dgn
\370-1105_hydtl

3"

"-1"
A’ " DIA. BAR

"
6"+D/24 CENTERED ON
l

2
SolOutfal

B-3 INNER BARS


D/24

"
2"
cs\13th_Del

1
* a B-1
TYP. 40

Z
L

KEY DETAIL

X
Q

"
SEE KEY DETAIL
P
i

1" TYP.
es\Hydraul

2
X-2
6" TYP.
N

U
1
ISOMETRIC VIEW
l
on\BE-370-1105\Sheet_Fi

1
" (TYP.) B-2 (TYP.)
6" . B-2 SIZE (TYP.)
P 1:1
Y HEADWALL TOP Y
T BEVEL
"
B A B
6
FOR REFERENCE ONLY
PIPE * a BARS SHALL BE EQUALLY SPACED IN GRATE
NOT TO EXCEED 8" CENTER TO CENTER
V
D/24 OR LESS THAN 6" CENTER TO CENTER. Not Official Bid Document
PLAN
Contact Horrocks Engineers
D

45
gati

INLET GRATE DETAIL


(SEE "HEADWALL DETAILS", DRAWING NO. 15, FOR DIMENSIONS)
ti
nage Mi

T: (208) 463-4197
BEVEL DETAIL
FEMA Storm water Drai

For Official Bid Documents


H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS ITD STD 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
3/8" = 1’-0" Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT KDH 11/27/2012 16 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
HEADWALL DETAILS JRS 12/03/2012
14
C * b MAX. 2’-0" * b MAX. 2’-0"

2" MIN.
SPACING SPACING
H-1A H-1A
W-1A

* b * b CONCRETE TABLE
H-1B

W -2
H-1B CONCRETE (C.Y.)

W -2
W-2 NOMINAL

W -2
W -2

W -2
SIZE WINGS
H-1B & FLOOR LIP TOTAL
DIA. (IN.)

2" MIN.
BCKWL.
AM

H-1B H-1B
11:49:37

42 1.3 1.3 0.3 2.9


METAL REINFORCEMENT TABLE
H-1A H-1A
BAR
MARK LOCATION SKETCH
SIZE

* b W -1C

L-2
W -1B
W -1A

W -1A

L-2
L-2
F-1 FLOOR NO. 4
L-1
TOP & BOTTOM
L-1 OF INLET NO. 4 SEE NOTE NO. 3
LIP IN FLOOR

SECTION C-C
HORIZ. IN TOP
ELEVATION
DECEMBER 2012

0
OF WING WALL
H-1A NO. 4 C

13
& IN FLOOR
2" MIN. * b ADDITIONAL BARS NEEDED WHEN

2" MIN.
BACK WALL
SPACE IS GREATER THAN 2’-0"
H-1A
2" MIN.
2" MIN.

HORIZ. IN

H
WING WALL * b MAX. 2’-0"

-
W -1B
PIPE

1B
H-1B BETWEEN SPACING
NO. 4
H-1As’ F-1
GRATE DIMENSION & MATERIALS TABLE
* b W-1C
(PAIRS ONLY) W-1A
IN INCHES

W -1A
W -1A
CULVERT
SIZE DIMENSIONS BAR SIZES

2
DIA. (IN.)

"
A’ * c X Y Z B-1 B-2 B-3 B-4

M
L-1

IN
42 44 65 116 72 1x 2x 2x2x 2xx9

.
EACH SIDE OF 2" MIN. * c ALLOW "-1" EXTRA BAR
PIPE IN PLAN * b MAX. 2’-0"
LENGTH FOR HOLE FABRICATION
_008.dgn

W-1A BACKWALL, NO. 4 SPACING


9

FLOOR, & BAR LOCATION DETAILS


0
9

INLET LIP
\370-1105_hydtl

HEADWALL DIMENSION TABLE


0

NOMINAL
9

IN INCHES
IN FLOOR, & SIZE NOTES
W-1B NO. 4
l
SolOutfal

INLET LIP DIA. (IN.) D/24 B M P V


A H L N Q U

42 1 45 47 53 67 57 53 61 64 43 140
cs\13th_Del

1. CAST-IN-PLACE HEADWALLS SHALL CONFORM TO SECTION


0
9

703 - CAST IN PLACE CONCRETE, OF THE CURRENT IDAHO


IN FLOOR, & STANDARD FOR PUBLIC WORK CONSTRUCTION (ISPWC) SPECIFICATIONS.
W-1C NO. 4
INLET LIP
2. THE METAL REINFORCEMENT SHALL BE NO. 4 BARS. ALL
i
es\Hydraul

METAL REINFORCEMENT TABLE


REINFORCEMENT SHALL HAVE A MINIMUM CONCRETE COVER OF
PIPE SIZE DIAMETER (IN.) 2" AND 3" MINIMUM COVER IF CAST AGAINST EARTH.

VERTICAL BAR 42 3. ALL EDGES TO HAVE " CHAMFER OR TOOLED EDGES.


l
on\BE-370-1105\Sheet_Fi

L-2 IN FLOOR, & NO. 4 NO./LGTH.


4. ALL PIPE CULVERTS WITH A CONCRETE HEADWALL SHALL
INLET LIP
F-1 2 79/109 HAVE THE INLET HEADWALLS BEVELED.
H-1A 2 182
5. THE METAL FOR THE GRATE SHALL MEET THE REQUIREMENTS
H-1B 6 67
FOR REFERENCE ONLY OF ASTM A 36. WELDING OF THE METAL GRATE SHALL MEET
L-1 2 136 THE REQUIREMENTS OF THE AMERICAN WELDING SOCIETY
VERTICAL IN 2
L-2 19 D1.1. GRATES NEED NOT BE
W-2
WING WALLS
NO. 4
2 127
Not Official Bid Document PAINTED OR GALVANIZED.
W-1A
gati

W-1B 1 68
Contact Horrocks Engineers 6. NOT TO SCALE.
ti
nage Mi

W-1C 2 47

W-2 6 57
T: (208) 463-4197
FEMA Storm water Drai

TOT. WT. 113 lbs.

For Official Bid Documents


H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS ITD STD 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
3/8" = 1’-0" Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT KDH 11/27/2012 17 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
HEADWALL DETAILS JRS 12/03/2012
15
2
1
S
U

3 CONSTRUCTI
ON DETOUR SI
GNI
NG
18 18
11:49:39 AM

18 W20-2B
Do 10 48" X 48"
wnRi
v 2 DETOUR
erRoa
ROAD
9 d 16 1 CLOSED
W20-3B AHEAD
48" X 48"
500 FT
15
17 17 DIKE BYPASS D-3A(o)
ROAD
20 36" X 18"
17
26
14 DIKE BYPASS ROAD
DIKE BYPASS
ROAD D-3A(o)
DIKE BYPASS
ROAD D-3A(o)
13 36" X 18"
(US 12) CLOSED 4 5 36" X 18"
d 3 DETOUR DETOUR
lRoa AHEAD USE M4-9L M4-9R
ai
tona 30"X 24" 30"X 24"
12
Rece
r ALTERNATE ROUTE

aland 23
dusr
ti SC-1
n
I 72" X 48"
DECEMBER 2012

U
4 DIKE BYPASS D-3A(o) DIKE BYPASS D-3A(o) DIKE BYPASS D-3A(o)

S
ROAD ROAD
17 36" X 18" 36" X 18" ROAD
36" X 18"
8

-1
18 2 7 5 6 M4-8 7 M4-8 M6-3(o)
DE
TOUR DE
TOUR

2
6 24" X 12" 24" X 12" 21"X 15"

/D
M5-1L M5-1R
8 25 21"X 15" 21"X 15"
10

i
19

ke
8
16
Bridge Street 24
DE
TOUR
M4-8
DE
TOUR
M4-8
DE
TOUR
M4-8
5 B 24" X 12" 24" X 12" 24" X 12"
8 1
DSt 7 yp 9 WEST M3-4
10 WEST M3-4
11 EAST M3-4
reet as WORK ZONE
24" X 12" 24" X 12" 24" X 12"
8 s M1-4 M1-4 M1-4
3 13 6 R
oa 12 24" X 24"
12 24" X 24"
12 24" X 24"
d M5-1L M5-1L M5-1L
FOR REFERENCE ONLY 4 24 21" X 15" 21" X 15" 21" X 15"
eet

1
r

Not Official Bid Document


h St

M4-8 M4-8 M4-8


5 DE
TOUR 24" X 12"
DE
TOUR DE
TOUR

eet
24" X 12" 24" X 12"
-1.dgn

7
15t

M3-4 M3-2 M3-2


12 EAST 13 EAST 14 EAST
Contact Horrocks Engineers 8 24" X 12" 24" X 12" 24" X 12"

r
\370-1105_trafcntl

25

h St
M1-4 M1-4 M1-4
8
Mai
nSt
12 24" X 24"
12 24" X 24" 12 24" X 24"
T: (208) 463-4197 ree
M5-1L M6-1 M6-1

5t
t 21" X 15" 21" X 15" 21" X 15"
22
22 2
For Official Bid Documents 8

eet
20
l
SolOutfal

M4-8 M4-8 M4-8


4 DE
TOUR DE
TOUR 24" X 12"
DE
TOUR 24" X 12"
24" X 12"

r
h St
21 15 WEST M3-4 16 WEST M3-4
17 EAST M3-2
24" X 12" 24" X 12" 24" X 12"
cs\13th_Del

M1-4 M1-4 M1-4


NOTES

18t
2 14 12 24" X 24" 12 24" X 24"
M6-1
12 24" X 24"
M6-3

eet
M6-1
21" X 15" 21" X 15" 21" X 15"
1. THE CLOSURE AS SHOWN SHALL NOT EXCEED

eet
12

r
i

h St
es\Hydraul

TWO WEEKS TOTAL TIME.

r
verAvenue

21stSt
8t
END END
2. WHILE THE US-12/DIKE BYPASS ROAD IS CLOSED, DE
TOUR M4-8 G20-5 G20-5
17 DETOUR DETOUR
24" X 12" 30" X 24" 30" X 24"
l

MAIN STREET MUST BE PAVED WITH ALL LANES


on\BE-370-1105\Sheet_Fi

M3-4 M3-4 M3-4


16th Avenue 18 WEST 19 20
OPEN TO TRAFFIC. NO WORK SHALL BE DONE ON 24" X 12" WEST 24" X 12" EAST 24" X 12"

US-12 AND MAIN STREET CONCURRENTLY. S M1-4 M1-4 M1-4


ou
t
hw 14
12 24" X 24"
M6-3 12
24" X 24"
12
24" X 24"
Snake Ri

3. THIS TRAFFIC CONTROL PLAN IS FOR THE ay 17 26 13


21" X 15"

B 12
STORMWATER DRAINAGE OUTFALL PROJECT ri
dg
WHICH INCLUDES 13th STREET, DELSOL LANE, e 17
DETOUR
M4-10L
DETOUR
M4-10R

Th
DIKE BYPASS
AND 9th STREET OUTFALLS. D-3A(o) 48" x 18" 48" x 18"
ROAD ROAD CLOSED ROAD CLOSED
gati

36" x 18" 0.25 MILES AHEAD 0.70 MILES AHEAD


21 22 R11-3 23 R11-3

ai
LOCAL TRAFFIC ONLY LOCAL TRAFFIC ONLY
END G20-5
ti

60" x 30" 60" x 30"

nR
nage Mi

DETOUR 30" X 24"


Br

TYPE III TYPE III


yd

BARRICADE BARRICADE

oa
DE
TOUR
M4-8 14 LEGEND
en
FEMA Storm water Drai

24" X 12" R11-2

d
26 13 48" X 30"
M3-4
26 EAST SIGN
C

24" X 12" ROAD


an

ROAD W20-3B
M1-4 3 24 25 CLOSED
CLOSED 48" X 48"
BARRICADE
12 24" X 24"
yo

1000 FT
M5-1L
n

21" X 15"
DIRECTION OF TRAVEL TYPE III BARRICADES
R
oa
d
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DEL SOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.

NTS
5700 East Franklin Rd.
Suite 160
Nampa, ID 83687
(208) 463-4197

FEMA STORMWATER DRAINAGE PROJECT BRS 11/27/2012 18 OF 21


IF THIS BAR DOES NOT
VERTICAL CHECKED DATE DRAWING NO.
REV DATE BY DESCRIPTION MEASURE 1" THEN TRAFFIC CONTROL
REVISIONS N/A DRAWING IS NOT TO SCALE 16
JRS 12/03/2012
Remove existing storm drain pipe. Removal is incidental to the new
2
stormdrain components and no separate payment will made.

N
Remove existing manhole or inlet. Removal is incidental to the new
3
stormdrain components and no separate payment will made.

Removal and replacement of curb and gutter, irrigation pipes, valve boxes etc.
4
0 50 100 200 for the bore excavation (see plan) will be considered incidental to bid item No. 21
SP-308.4, Steel Casing Pipe Boring and Jacking, 54" (diameter). No separate
payment will be made for this work.
FEET
11:49:59 AM

FOR REFERENCE ONLY


NOTES:
Not Official Bid Document
Mainline Type "P" Surface Restoration, (Asphalt Roadway)
20
Item 307.4.1.G.1

Contact Horrocks Engineers

T: (208) 463-4197
T
REE
O ST

For Official Bid Documents


DAH
DECEMBER 2012

1. Curb & gutter, sidewalk, manholes and utilities not shown to be removed or abandoned
I

shall be preserved and protected in place.

MI
LLERS
TREE 2"
T

"
2"
_001.dgn
\370-1105_rem vl

T
EE
STR
13TH

6"
15" CONC
2
REMOVAL: 265 LF
l

FUTURE WORK
SolOutfal

4"

6"
3
cs\13th_Del

4
i
es\Hydraul

3
F STREET

20

309 SY

RAI

US-
l
on\BE-370-1105\Sheet_Fi

4"
T

LROAD M AI

12/
EE
"

STR
3TH

DI
G STREET

1
6"

KE BYPASS ROAD
N LI
NE
gati

FUTURE WORK "


ti
nage Mi

2"
FEMA Storm water Drai

J
EFFERSONSTREET
DAHO STREET

20 ACOE BOUNDARY

178 SY
6"
I
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS DLJ 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 50’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 19 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE
REMOVAL AND ASPHALT REPLACEMENT PLAN 1 17
KDH 12/03/2012
STREET

N STREET

N
2"

RAI
DAHO

LRO
M AI
0 50 100 200

AD S
I

G STREET

PUR
FEET
AM
11:50:24

US H
I
RAI

GH
RAI

W AY
LRO
LRO

AD M
MAIN LINE TYPE "P"

12 (
SURFACE RESTORATION

AD S
20
T

DI
REE (ASPHALT ROADWAY)

AI
THST

KE
14 AREA = 1118 SY

N LI
PUR
2"

BYPA
NE
N STREET

SS)
DECEMBER 2012

M AI
18" CERAMIC
REMOVAL:
REMOVAL: 280 LF:
2" 2

6"
46 LF 18" CMP 2
REMOVAL
REMOVAL: 2
150 LF
28 LF
(APPROXIMATE)
3

3-PH
2"
3

ASE
2"
T 2"
REE
HST

UNDE
15T
SALVAGE AND REPLACE
MAIN LINE TYPE "P" EXISTING GRAVEL BASE

RG
6"
SURFACE RESTORATION MATERIAL
20

ROUN
(ASPHALT ROADWAY)
AREA = 170 SY
_003.dgn

D
2"
\370-1105_rem vl

FUTURE WORK
2"

2"
l
SolOutfal

2"
6"
cs\13th_Del

LANE
SOL
DEL
i
es\Hydraul

ET

6"
TRE
l

T
on\BE-370-1105\Sheet_Fi

REE
6THST
1
O S
DAH

6"

NOTES:
I

3 Removal of Sidewalk, Item 201.4.1.D.1 Remove existing storm drain pipe. Removal is incidental to the new
2
stormdrain components and no separate payment will made.
2" Mainline Type "P" Surface Restoration
20
(Asphalt Roadway), Item 307.4.1.G.1 Remove existing manhole or inlet. Removal is incidental to the new
3
stormdrain components and no separate payment will made.
gati

FOR REFERENCE ONLY


ti
nage Mi

G STREET

Not Official Bid Document


FEMA Storm water Drai

Contact Horrocks Engineers

T: (208) 463-4197
1. Curb & gutter, sidewalk, manholes and utilities not shown to be removed or abandoned shall be
preserved and protected in place.

For Official Bid Documents


H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS DLJ 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 50’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 20 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE
REMOVAL AND ASPHALT REPLACEMENT PLAN 2 18
KDH 12/03/2012
CLEARWATER RIVER

N
FOR REFERENCE ONLY
AM

DURING ACCESS CLOSURE TO PARKING AREA.

13TH STREET
PROVIDE BARRICADES/TRAFFIC CONES Not Official Bid Document
11:50:44

0 100 200 400 AS REQUIRED. A DETAILED DESCRIPTION


STORM DRAIN
OF CONSTRUCTION WORK AND DURATIONS
OUTFALL
NEAR ACCESS CLOSURE SHALL BE PROVIDED
BY THE CONTRACTOR TO THE ENGINEER FOR Contact Horrocks Engineers
FEET APPROVAL. CONTRACTOR SHALL MINIMIZE
ACCESS CLOSURE TIME.
U.
S.HI
GHWAY12
T: (208) 463-4197
DELSOL LANE
CLOSURES DURATIONS AT THIS LOCATION STORM DRAIN
SHALL BE AS SHORT AS POSSIBLE. WHEN MAIN OUTFALL For Official Bid Documents
STREET ACCESS IS BLOCKED, 13TH STREET
AND F STREET SHALL BE KEPT OPEN.
TRUCKS WILL REQUIRE ACCESS
WHEN MAIN STREET ACCESS THROUGH THIS LOCATION.
IS BLOCKED, 13TH STREET PROVIDE TEMPORARY FENCE
DECEMBER 2012

AND F STREET SHALL BE AND GATE FOR CONSTRUCTION


KEPT OPEN AREA. GATE SHALL BE LOCKED
DURING NIGHT HOURS.

MAI
NST
REE
T

FST
REE
T

13TH STREET

ET
TRE
NS
SO
ty.dgn

EET
FER

STR
ni

JEF
ci
\370-1105_Vi

LN
NCO

DELSOL LANE
LI
l
SolOutfal

GS
TREE
T
i
es\Hydraulcs\13th_Del

ET

15TH STREET
PT 641
RE

IN WEST 732.01 18"


ST

IN SE 732.21 18"
l
on\BE-370-1105\Sheet_Fi

ER

RI
LL

GB I
DAH
OS
MI

Y TREE
LA T
NE

16TH STREET
14TH STREET
NOTES:
gati

1. Critical access requirements as shown on this sheet shall be included in the


work traffic control plan developed by the Contractor. Work and materials
ti
nage Mi

necessary to meet these requirements shall not be paid for separately but
shall be included under Bid Item 1103.4.1.B.1 Traffic Control.

2. These critical access requirements shall be in addition to the roadway traffic


FEMA Storm water Drai

control as required for the installation of the storm drainage system.

3. The Contractor shall provide notification of any access closures to the Engineer
prior to closing the access. Approval of the closure by the Engineer will be
required prior to construction causing restriction of the access. The Contractor shall
cooperate with the Engineer and the City of Lewiston personnel to minimize disturbance
to businesses, public facilities and residences. Where possible alternate access
or detours shall be provided for durations lasting longer than one business day.
H:\!2011\BE-370-1105

DESIGNED DATE PROJECT NO.

SCALE WARNING 13th STREET AND DELSOL LANE OUTFALLS KDH 11/27/2012 BE-370-1105
5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
1" = 200’ Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/27/2012 21 OF 21
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
CRITICAL ACCESS PLAN JRS 12/03/2012
19
BRITISH
COLUMBIA
CANADA
UNI
T ED 95 STATES CITY OF LEWISTON IDAHO
2

W ASHINGTON
2
Coeur
d’Alene
Pend
Orielle
Lake
9th STREET OUTFALL
90
95
FEMA II STORMWATER DRAINAGE PROJECT
Moscow PROJECT LOCATION

12
Lewiston

95

M
O

U
N
93

S
TA

H
N

I
A

G
H
W
SN

A
Y
A
K
AM

12
E

20

(D
YELLOWSTONE

N
8:08:04

I
95

K
NATIONAL
OREGO N

E
PARK

93

B
15
75

Y
P
IDAHO

INDEX OF DRAWINGS

A
BOISE

S
W YOM ING
20

S
)
26 IDAHO
84 20
R

I FALLS
V 26
Mountain
E

Home
R

95 DRAWING NO. DESCRIPTION


26 American Falls POCATELLO
Reservoir

86
30 CLEARWATER RIVER 1 TITLE, LEGEND AND INDEX OF DRAWINGS
Twin Falls 89
2 GENERAL NOTES
30 3 SURVEY CONTROL
93 84 15 91 89
4 9TH STREET OUTFALL PLAN AND PROFILE
NEVADA UTAH
5 TRAFFIC CONTROL DETAILS AND GENERAL NOTES
6 US 12 CROSSING DETAILS (9TH ST)
7 - 8 HEADWALL DETAILS

EET
9 TRAFFIC CONTROL

STR
7TH
LEGEND

ET
RE
ST
DECEMBER 2012

H
8T
WM EXISTING WATER METER

EXISTING VALVE D
ST
R
EE
HYD EXISTING FIRE HYDRANT T
M
EXISTING IRRIGATION SPRINKLER AI
N
ST
R
EE
EXISTING STORM DRAIN MANHOLE T

EXISTING STORM DRAIN INLET

E
N
LA
EXISTING SANITARY SEWER MANHOLE
9th STREET

E
PL
STORM DRAIN
EXISTING STREET LIGHT
OUTFALL

M
TE
ET

EXISTING GUY WIRE ANCHOR


RE
ST

EXISTING ELECTRICAL BOX


H
6T

EXISTING SIGN
FOR REFERENCE ONLY
W
e_001.dgn

NE

EXISTING SIDEWALK AND CURB


US
HI
GH
W
Not Official Bid Document
EXISTING TREE OR SHRUB AY
tl

ET
RA 12
es\332-1209_ti

IL (
DI
RO
RE
KE

PROPOSED OUTFALL LINE


F
ST
R
ST RA
ILR
OA
AD
MA
I
N
BY
PA
SS
Contact Horrocks Engineers
EE D L )
I
NE
H

T SP R
9T

UR AIL
PROPOSED STORM DRAIN MANHOLE ROA
LI
NE DS
PU
RL
T: (208) 463-4197
PROPOSED STORM DRAIN INLET I
NE
l

ET
lProject\Project Data\Sheet_Fi

ET
For Official Bid Documents
RE

RE
MAI
ST
NS
TREE

ST
NOTE: T
TH

SEE LEGEND ON PLAN AND PROFILE SHEETS FOR THE

TH
10

FOLLOWING EXISTING UTILITIES:

11
EXISTING FIBER OPTIC
EXISTING GAS
EXISTING IRRIGATION
EXISTING OVERHEAD ELECTRICAL
EXISTING SANITARY SEWER
EXISTING STORM DRAIN
EXISTING TELEPHONE VICINITY MAP
EXISTING WATER
IOutfal

EXISTING PUBLIC WATER LATERAL


H:\!2012\BE-332-1209 FEMA I

DESIGNED DATE PROJECT NO.

SCALE WARNING 9th STREET OUTFALL KDH 11/15/2012 BE-332-1209


5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
N/A Nampa, ID 83687 FEMA II STORMWATER DRAINAGE PROJECT MRW 11/15/2012 1 OF 9
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
TITLE, LEGEND AND INDEX OF DRAWINGS 1
TLH 12/03/2012
GENERAL CONSTRUCTION ROADWAY
1. All construction work shall conform to the City of Lewiston Standards and Specifications and the current version 1. All Contractors working within the public road right-of-way are required to secure a right-of-way construction
of the Idaho Standards for Public Works Construction (ISPWC). In the case of conflict, the Project Plans and permit from the City of Lewiston at least twenty-four (24) hours prior to any construction.
Technical Specifications will prevail over City Standards which will prevail over ISPWC. Paving US-12 shall be
per ITD Standard Specifications. 2. The City of Lewiston will inspect all work within the public rights-of-way to include utility trenches above the pipe
zone. The City will inspect all connections to existing infrastructure (water, sewer, and storm drain).
2. All Contractors and Utility Contractors shall attend a pre-construction conference (and on-site meeting with the
City of Lewiston Public Works Supervisor) prior to start of work. The Contractor shall conduct a weekly project WATER/SEWER
meeting with the Engineer and City. 1. Construction of potable water lines shall conform to the standards in the "Idaho Rules for Public Drinking Water
Systems (IDAPA 58.01.08)" as well as the standards and specifications referred to in General Construction
3. Contractors shall notify the appropriate agency when materials are on site or inspection of the work is required. Note No. 1.
No work may begin on any project without Twenty Four (24) hour prior notice.
2. The horizontal separation of potable water mains and non-potable water mains (sanitary sewer, storm drain, and
8:08:06 AM

4. Work subject to approval by any governmental agency must be approved prior to (A) backfilling trenches for irrigation) shall be a minimum of ten (10) feet. Where it is necessary for a potable water main and non-potable
pipe; (B) placing of aggregate base; (C) placing of concrete; (D) placing of asphalt paving. All newly installed water main to cross with less than eighteen (18) inches of vertical separation, the crossing shall be constructed
lines shall be videoed per Public Works Standards prior to final payment. in accordance with Section 542.07 of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08) and
Section 430.02 of the Wastewater Rules (IDAPA 58.01.16).
5. Inspection, approval and final acceptance of all construction shall be by the Public Works Department, and
their decision shall be final. Such inspections shall not relieve the contractor from the responsibility of performing 3. The Contractor shall be responsible for notifying existing water users prior to disrupting service. No user shall be
the work in an acceptable manner in accordance with the DEQ approved construction plans. without water or sewer service overnight. No user shall be without water for more than 4 hours during normal
business hours.
6. Any deviation from the approved plans and specifications must have the applicable agency approval in writing
prior to construction. 4. All water works components shall be ANSI/NSF 61 Certified, and must meet all AWWA and standard requirements
of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08).
7. The Contractor shall promptly remove from the vicinity of the completed work, all rubbish, mud in streets,
removed materials, all excess material, construction equipment and temporary structure and facilities used STORM SEWER
during construction. Final acceptance and payment will be withheld until the Contractor has satisfactorily 1. All catch basins and manholes shall be constructed per City of Lewiston, Idaho Public Works Department Standards.
DECEMBER 2012

cleaned the site as determined by the Public Works Supervisor. See drawings 6-1 through 6-9 for drawing details. Stormwater Type 1 Catch Basin, Std. Dwg 6-8 shall be provided
at all locations where pipe sizes permit. Stormwater Type 1a Catch Basin, Std. Dwg 6-9 shall be provided at all
8. Adjacent streets shall not be simultaneously closed. Contractor shall maintain critical access points. Properties locations where larger pipe sizes require their use. All catch basins shall have curb openings unless it is located
with water and sewer services impacted by construction activities shall be notified of construction activities 2 days within a driveway. Curb openings may be eliminated only in special circumstances and only as approved by the
prior to disturbing their service(s). Engineer. Where inlet locations have moved along the curb from the existing location to a new location, the flow line
of the gutter shall be formed to ensure positive drainage to the new inlet location. Slopes shall not exceed 20%
9. If needed, the design, construction, installation, maintenance and materials to complete a temporary dewatering unless approved by the Engineer. Field verification that gutter flow can be achieved shall be performed by the
system to provide adequate dewatering during construction will not be measured and paid for separately but contractor prior to the installation of the inlet.
included in the project.
2. Removal of existing storm drain manholes, catch basins, and pipe within the project limits shall be incidental to the
new pipe, manhole or inlet being installed in the same or nearby location. The City will retain ownership of all
es\332-1209_Gen Notes_001.dgn

removed frames, grates, and lids. Contractor shall stockpile removed items in the location designated by the City.
Pipes, catch basins, inlets and manholes that shall be removed or abandoned are shown on the removal plan.
FOR REFERENCE ONLY Pipes to be abandoned shall be plugged at the disconnected end with a concrete plug. Manholes deeper than
4 feet, and not in conflict with proposed storm drain, may be abandoned by removing the top 4 feet of the
Not Official Bid Document
manhole riser and backfilling with 34" aggregate or flowable fill. Compaction within and above the abandoned

Contact Horrocks Engineers manhole shall be required.


l
lProject\Project Data\Sheet_Fi

T: (208) 463-4197 3. All manhole lids shall be rotated on structure so they are out of wheel paths.

For Official Bid Documents 4. Locations are called out in the plans to connect existing storm drain components to new storm drain components.
All work and materials for connections shall be considered incidental to the new storm drain components. Industry
standard connections shall be used. When coring and grooving is required, a non-shrink grout shall be used.
IOutfal
H:\!2012\BE-332-1209 FEMA I

DESIGNED DATE PROJECT NO.

SCALE WARNING 9th STREET OUTFALL KDH 11/15/2012 BE-332-1209


5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
N/A Nampa, ID 83687 FEMA II STORMWATER DRAINAGE PROJECT MRW 11/15/2012 2 OF 9
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
CHECKED
REV DATE BY DESCRIPTION MEASURE 1" THEN GENERAL NOTES
REVISIONS N/A DRAWING IS NOT TO SCALE 2
TLH 12/03/2012
6TH AVEN LEWISTON SURVEY CONTROL
UE N

CONTROL POINT 1A

ET N
N 1734533.069

ET N
E 2302172.355

15TH STRE

ET N
ELEV. 831.617
CITY MONUMENT

17TH STRE
N

18TH STRE
CONTROL POINT 2A
5THNA1734566.387
VENUE N
E 2307752.025
ELEV. 741.815
CITY MONUMENT
3
R
D
A CONTROL POINT 51
V
B ST E N 1734024.882
REET 0 250 500 1000 N
U
E E 2303621.906
N
4THELEV. 838.897

ET
AVENUE
ET

FND TRUESN #18

DI
SURVEY FEET
ET

STRE
STRE

B ST

KE
REET
ET
STRE

C ST
S T RE

ET

BY
REET PROJECT SURVEY CONTROL

5TH
1ST

PA
STRE
8:08:08 AM

2ND

SS
CONTROL POINT 20
3RD

C ST
REET 3RD A
NVE
1734972.690
NUE N
4TH

ET
E 2306881.626
D ST ELEV. 749.717

RE
REET

ST
ET
D STR CONTROL POINT 22C
EET

STRE
N 1735697.143

H
7T
E 2304750.379
ELEV. 749.011
CL

6TH
U
MAI S EA
N ST
REET H RW
BOUL IG
CT EVAR AT
PE

T
D H ER
OS W

E
PR A RI

RE
Y VE
N R

ST
O CONTROL
12 POINT 22C
PROSPECT BOULEV ARD

H
8T
NORTH STREET
F

E
N
S

A
T
R

L
E
E

T
T

E
E

T
E
9th STREET

E
R

E
1
ST AVENUE T STORM DRAIN
D
FOR REFERENCE ONLY

R
S

T
S OUTFALL
M T

S
R
H

A E
DECEMBER 2012

IN E

H
IX

T
S
T
Not Official Bid Document
S

9
R
E
E
W

T
E
N

2ND AVENUE F
Contact Horrocks Engineers
3RD STREET

5TH STREET
4TH

S
GLASS W AY

T
R
E
E
T
STREET

CONTROL
POINT 20
T: (208) 463-4197

T
E
MA
I

RE
N
ST
RE
For Official Bid Documents

ST
3RD AVENUE ET DI
KE B
3RD AVENU I YPAS
E DA S
T

TH
HO F
E

ST US
RE

ST

11
RE HI

12TH
RE ET GHW
AY
ST

ET NO
ST

1
2
ET

T
ET

E
H

RE
JO

6TH STRE

9T

STR

13TH STRE
CONTROL
T
H

ST
E

CONTROL POINT 2A
N’

RE

EE

T
POINT 1A
S

ET
E
N
ST

RE
es\332-1209_surv_001.dgn

SO
W

E
MA
E

IN
AY

ST

STR
RE

ST
TH

ER
RE
F ET
10

ST

ST

FF

LN
4TH AVEN RE
UE ET

H
JE

CO

NE
TH

18T
I
11

DA

REET
LIN

DELSOL LA
ET

HO
NE

ST
RE

RE
LA

CONTROL ET
ST

16TH ST
5TH AVEN
UE POINT 51
S

CHURCH S G MA
AM

TH

ST
ET

TREET RE IN
5TH AVEN ET ST

ET
RE
AD

RI
12

UE ET
3RD STRE

ET

GB
l

RE
lProject\Project Data\Sheet_Fi

Y
LA
4TH STRE

ST

NE
ET

I
DA
HO G
ET

ER

ST ST
7TH STRE

RE RE
ET ET
LL
8TH STRE

6TH AVEN
PA
RK
NOTES:
MI

UE
ST
RE 1. All Units are in U.S. Survey Feet, Grid Values are SPC Zone
ET

ET
6TH AVEN
E

UE 1103 (Idaho West), Geodetic Values are NAD83(1998/1999).


D

14TH STRE
A
ET

ET

Elevations are NAVD88.

ET
R
ET

G
5TH STRE

11TH STRE

15TH STRE
6TH STRE

I
DA 2. To convert ground distances to State Plane Grid distances,
ET

HO
ST scale using a combined factor of 1.00001547 (Pt 2A). The

NE
RE
ER

ET
9TH STRE

ET difference between grid distances and ground distances does

REET
DELSOL LA
LL

10TH STRE

not exceed 1:15,000 for the Idaho West Zone at all locations
IOutfal

MI

within this project so scaling may not be necessary depending


ET

16TH ST
on accuracy requirements.

ET
7TH AVEN
UE
3RD STRE

E)
ET

6TH AVEN
H:\!2012\BE-332-1209 FEMA I

17TH STRE
UE

ET
AD
4TH STRE

18TH STRE
GR

ET
6T
H
OE

AV

14TH STRE
EN
UE
(P

DESIGNED DATE PROJECT NO.

5700 East Franklin Rd. 9th STREET OUTFALL KDH 11/15/2012 BE-332-1209
HORIZONTAL 0 1/2 1 Suite 160 DRAWN DATE SHEET NO.

NTS
5700 East Franklin Rd.
Suite 160
Nampa, ID 83687
(208) 463-4197

Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/15/2012 3 OF 9


IF THIS BAR DOES NOT (208) 463-4197
VERTICAL CHECKED DATE DRAWING NO.
REV DATE BY DESCRIPTION MEASURE 1" THEN
NTS DRAWING IS NOT TO SCALE
SURVEY CONTROL 3
TLH 12/03/2012
NE

NE
NOTES:

LRO AD

12/
NE
UR LI

LI
NOTE:

N LI
N

AD SPUR

SS
GHW AY
RAI
M AI
1. RIGHT OF WAY LINES SHOWN ARE APPROXIMATE.

LRO AD SP
2 Removal of Obstruction, Item 201.4.1.C.1

KE BYPA
ITD ROW

US HI
0 20 40 80 7 Seedbed Preparation, Item 206.4.1.A.1

LRO

DI
FUTURE 24"

RAI

RAI
8 Seeding, Item 206.4.1.B.1
STORMDRAIN
SURVEY FEET ITD ROW
MAIN STREET ROW 9 Mulching, Item 206.4.1.C.1

36 10 Mulch Anchoring (tack), Item 206.4.1.E.1


8:08:30 AM

TEMPORARY 50’
MAIN STREET 4 22 60’ EXCAVATION LIMITS 4
SHORING
ROW FROM 2:1 SLOPE 12 Fertilizing, Item 206.4.1.G.1

CONSTRUCTION LIMITS SHALL TEMPORARY PRESERVE AND PROTECT


24 22 Main Line Type "P" Surface Restoration (Asphalt
NOT EXTEND BEYOND THE SHORING EXISTING IRRIGATION 20
Roadway), Item 307.4.1.F.1
EXISTING 9TH ST ROW
FUTURE 12" MH O-3 22 Temporary Shoring, Item SP-308A
54 20 3
STORMDRAIN STA. 13+36.08

25’
218 SY N 1735672.655 23 Flow Fill, Item SP-308B, See Detail
E 2304280.833

40’
LIMITS OF 24 Replace Railroad Base, Item SP-308C
EXCAVATION FOR 4
SINGLE TRENCH BOX Steel Casing Pipe Boring and Jacking, 48" (diameter),
26
Item SP-308.4
58 20 76’ PERMANENT STORM
2
23 36 Hydrant, Item 403.4.1.A.1
BORELENGT DRAIN EASEMENT
MH O-2 128 SY BOTTOM OF H
DECEMBER 2012

STA. 10+51.63 LIMITS OF PUSH PIT 36" Storm Drain Pipe, Type S, Corrugated Polyethylene
4 2 58 54
N 1735429.372 EXCAVATION 122’ 54 (CPP), Item 601.4.1.A.17F
E 2304133.444 FOR PUSH PIT CASI
NG LENGTH
58 Storm Drain Manhole, 72" Diameter, Item 602.4.1.E.1C
8’ STUBOUT FOR FUTURE 7 8 9 10 12
FUTURE 36" 54 1
CONNECTION, PLUG END
STORMDRAIN 77 Concrete Headwall (36")
FUTURE 36"
STORMDRAIN
26
FUTURE MH O-1
STA. 10+00.00 Cap pipe prior to backfill. See "PIPE CAP DETAIL".
1
FUTURE 36" N 1735377.743 Pipe cap shall be incidental to the pipe stubout.

STORMDRAIN E 2304132.692 RETAIN & 20
HEADWALL
RETAIN & PROTECT; Restore gravel surface to existing
PROTECT STA. 14+37.97 2
RAIL TO REMAIN condition. Restoration shall not be
RAIL, TIES N 1735687.897
OPEN AT ALL TIMES paid for separately but shall be
AND E 2304381.585

2/
incidental to 36" Storm Drain Pipe.
SECTION

BM
GHW AY 1
SS
Paving US Highway 12 Dike Bypass shall
EXISTING CLEARWATER 3
D STREET

KE BYPA
be per ITD Standard Specifications.
EFFLUENT LINE
PRESERVE AND PROTECT

US HI
4 Limits of Excavation are shown for estimating purposes
CONCRETE
77 only. The Contractor must confine construction activities

DI
HEADWALL
to be within the 20’ Storm Drain Easement as shown for
the construction of the outfall.
00 RT

NE)

EXISTING GROUND
00 RT

45 (

745 745
63, 0.

LEGEND
S)
00, 0.

55 (
NV OUT = 721.
14

EXISTING FIBER OPTIC


00
NV OUT = 722.

STA = 10+51.
1

N = 721.
FUTURE M H 0-

18
19

Head Loss1.

EXISTING GAS
00
STA = 10+00.

M = 735.

EXISTING CLEARWATER
N = 722.
13

Head Loss1.

EFFLUENT LINE EXISTING IRRIGATION


M = 734.

740 740
2
M H 0-

EXISTING OVERHEAD ELECTRICAL


NV I
RI

EXISTING SANITARY SEWER


NV I

I
I
RI

EXISTING STORM DRAIN

00 RT
I
I

E)
EXISTING TELEPHONE

SW )
71 (
08, 0.
735 735
EXISTING WATER

83 (
NV OUT = 717.
HYDRAULIC GRADE LINE
es\332-1209_hydr_001.dgn

00
STA = 13+36.

N = 717.
26
EXISTING GROUND

Head Loss1.
M = 725.
ESTIMATED FULL BUILD HYDRAULIC GRADE LINE

3
730 730

M H 0-

NV I
RI
I
I
Headwall
48" STEEL CASING
725 725
l
lProject\Project Data\Sheet_Fi

720
F
INV. 720
FOR REFERENCE ONLY
UTURE3 6INCH
ELEV.
L=8’
36I
NCH 716.37
Not Official Bid Document
43

S=1.30%
STA.11+41.

Fl
ow= L=280’
103.
28CFS(112Ac
43

r
es) STUBOUT STORM DRAIN PIPES S=1
Fl
ow=103. .30%
56CF
STA.12+53.

S(100Ac
res) 3
AND CAP ENDS Fl
ow=103.
18 6INCH
715 CFS(
112Acres 715
)
Fl
ow=103.
42CFS(100Ac
res)
L=9
S=1
0
.
3

5%
Contact Horrocks Engineers
Fl
ow=102.
61CFS(
112Acres)
Fl
ow=102.
64CFS(100Ac
res) T: (208) 463-4197
710 710
IOutfal

10+00 11+00 12+00 13+00 14+00


For Official Bid Documents
H:\!2012\BE-332-1209 FEMA I

DESIGNED DATE PROJECT NO.

SCALE WARNING 9th STREET OUTFALL KDH 11/16/2012 BE-332-1209


5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.

1" = 40’
Suite 160
Nampa, ID 83687
FEMA II STORMWATER DRAINAGE PROJECT MRW 11/16/2012 4 OF 9
IF THIS BAR DOES NOT
VERTICAL (208) 463-4197 CHECKED DATE DRAWING NO.
REV DATE BY DESCRIPTION MEASURE 1" THEN 9TH STREET OUTFALL PLAN AND PROFILE
REVISIONS 1" = 10’ DRAWING IS NOT TO SCALE 4
TLH 12/03/2012
W20-1
36"x36"

A H EA D
W O RK
w o rk

RO A D
END
G20-2

DEWALK
CLOSED
W1-4L

ro a d
36"x18"

DEW A LK CLOSED
36"x36"

C R O S S H ER E
R9-9

A HEA D
24"x12" R9-11

SI
24"x18"

SI
100’ 125’ 125’ 45’ 100’ 100’

(SHIFTING (SHLDR
COVER END OF PIPE
TAPER) TAPER)
WITH 3/8" DIAMOND
PLATE STEEL

3/8" DIAMOND
TYPE II
PLATE STEEL
BARRICADE
8:08:33 AM

D STREET
WORK
ZONE
COMPACTED
3/4" AGGREGATE

AM ETER + 4"
CHANNELIZING
CONE (TYP.)
100’ 100’ 125’ 100’

OUTER DI
AHEAD W1-4R
WORK
ROAD

road work
36"x36"

END
W20-1
36"x36"

)
TYP.
4"
(
W1-4R COMPACTED
G20-2 3/4" AGGREGATE
36"x36"
36"x18" 4"
(TYP.)
SIDE VIEW FRONT SECTION
DECEMBER 2012

9TH STREET
PIPE CAP DETAIL

NOTE:
CONTRACTOR SHALL MAINTAIN ONE LANE OF TRAFFIC
AT ALL TIMES ON D STREET.

D STREET TRAFFIC CONTROL


_001.dgn

FOR REFERENCE ONLY


es\332-1209_hydtl

GENERAL NOTES:
1. IF THE TRAFFIC CONTROL PLAN AS SHOWN DOES NOT CONFORM TO
THE CONTRACTOR’S METHOD OF OPERATION, THE CONTRACTOR
7. ALLOW ACCESS TO PROPERTY OWNERS AT ALL TIMES.
Not Official Bid Document
SHALL SUBMIT NEW TRAFFIC CONTROL PLANS TO THE ENGINEER 8. MAINTAIN ONE TRAVEL LANE IN EACH DIRECTION DURING
FOR APPROVAL PRIOR TO BEGINNING CONSTRUCTION. NON-WORKING HOURS.
Contact Horrocks Engineers
2. ALL REQUIRED CONSTUCTION SIGNING AND TUBULAR MARKERS 9. NO LANE CLOSURES BETWEEN THE HOURS OF 7:00 AM TO
SHALL BE IN PLACE PRIOR TO ANY DIVERSION OF TRAFFIC WITHIN 9:00 AM AND 4:00 PM TO 6:00 PM WILL BE ALLOWED WITHOUT
l
lProject\Project Data\Sheet_Fi

THE PROJECT. WRITTEN APPROVAL.


T: (208) 463-4197
3. ADDITIONAL SIGNING MAY BE REQUIRED AS DIRECTED BY THE
ENGINEER.
For Official Bid Documents
4. ALL CONSTRUCTION WARNING SIGNS SHALL HAVE TWO WARNING
FLAGS. A BATTERY OPERATED FLASHING WARNING LIGHT SHALL BE
IN PLACE DURING HOURS OF DARKNESS. THE CONTRACTOR SHALL
NOT IMPEDE TRAFFIC DURING NON-WORKING HOURS WITHOUT
WRITTEN APPROVAL FROM THE ENGINEER.

5. WORK ZONE SIGNS SHALL BE MOUNTED AT A MINIMUM 5’ (FOOT)


MOUNTING HEIGHT, MEASURED TO THE BOTTOM OF THE SIGN.
SIGNS AND SIGN SUPPORTS SHALL MEET THE NCHRP-350 CRASH
IOutfal

WORTHINESS STANDARD.

6. FLAGGERS SHALL BE USED AS DIRECTED DURING CONSTRUCTION


H:\!2012\BE-332-1209 FEMA I

DAYLIGHT HOURS.

DESIGNED DATE PROJECT NO.

5700 East Franklin Rd.


9th STREET OUTFALL KDH 11/15/2012 BE-332-1209
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
NTS
5700 East Franklin Rd.
Suite 160
Nampa, ID 83687
(208) 463-4197

Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT MRW 11/15/2012 5 OF 9


IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
N/A DRAWING IS NOT TO SCALE
TRAFFIC CONTROL DETAILS AND GENERAL NOTES TLH 12/03/2012
5
2/
GHW AY 1
NOTES:

SS

N
KE BYPA
1. SEE 9TH STREET OUTFALL PLAN AND PROFILE FOR ADDITIONAL
INFORMATION.

US HI
2. RIGHT OF WAY LINES SHOWN ARE APPROXIMATE.

DI
0 10 20 40

1 LIMIT DISTURBANCE OF US 12/DIKE BYPASS TO THE MAXIMUM


50’ SURVEY FEET
1 AS SHOWN ON THE PLANS. PATCHING AND REPAIR SHALL BE
PAID FOR AS ITEM 307.4.1.F.1, MAIN LINE TYPE "P" SURFACE
RESTORATION (ASPHALT ROADWAY).

TEMPORARY
SHORING

PERMANENT
STORMDRAIN
EASEMENT
A
8:08:45 AM

PIPE DETAIL
MH 0-3
1 N.T.S.
STA = 13+36.08
40’

N 1735672.655 EXISTING GROUND


E 2304280.833

M ATELY 8"
ELD SURVEY
CLEARWATER PAPER

APPROXI
EFFLUENT LINE

PER FI
A’

LIMITS OF EXCAVATION
FOR SINGLE TRENCH BOX, FLOW FILL
(SEE "9TH STREET OUTFALL
PLAN AND PROFILE" SHEET)
36" STORM DRAIN PIPE
DECEMBER 2012

PIPE BEDDING
A A’

ALONG CENTERLINE OF CLEARWATER EFFLUENT LINE


36" STORM DRAIN PIPE

FOR REFERENCE ONLY


_002.dgn

EXISTING ROW
EXISTING CLEARWATER
PAPER EFFLUENT LINE CONCRETE HEADWALL
Not Official Bid Document
es\332-1209_hydtl

2/

Contact Horrocks Engineers


GHW AY 1
SS
KE BYPA

’ T: (208) 463-4197
US HI

20
DI
l
lProject\Project Data\Sheet_Fi

For Official Bid Documents


IOutfal
H:\!2012\BE-332-1209 FEMA I

DESIGNED DATE PROJECT NO.

SCALE WARNING 9th STREET OUTFALL KDH 11/16/2012 BE-332-1209


5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160

1"=20’
Nampa, ID 83687 FEMA II STORMWATER DRAINAGE PROJECT DLJ 11/16/2012 6 OF 9
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
REV DATE BY DESCRIPTION CHECKED
MEASURE 1" THEN
REVISIONS N/A DRAWING IS NOT TO SCALE
US 12 CROSSING DETAILS (9TH ST) TLH 12/03/2012
6
3"

" NC MACHINE BOLT


3"
6"+D/24 W/NUT AND LOCK NUT
A B
SEE B-4 DETAIL B-4
"
SEE BEVEL DETAIL

8"+D/12
A-1"
6" 2"
(2) B-4
BARS
"

H
7"

D
AM

B-4 DETAIL
8:08:47

9"
9"
1:1 BEVEL (SEE NOTE 36" STORM
KEY
NO. 5 & BEVEL DETAIL) 36" STORM DRAI
N PI
PE
DRAIN PIPE

-0"
2’
A B 6" 6"

1:1 BEVEL (SEE NOTE


ELEVATION SECTION A-A SECTION B-B NO. 5 & BEVEL DETAIL)
DECEMBER 2012

3"

"-1"
A’ " DIA. BAR

"
6"+D/24 CENTERED ON

2
B-3 INNER BARS
D/24

"
2"

1
* a B-1
TYP. 40

Z
L

KEY DETAIL

X
Q
_003.dgn

"
SEE KEY DETAIL
P

1" TYP.

2
X-2
6" TYP.
N
es\332-1209_hydtl

U
1
ISOMETRIC VIEW
1
" (TYP.) B-2 (TYP.)
6" . B-2 SIZE (TYP.)
P 1:1
Y HEADWALL TOP Y
T BEVEL
"
6
B A B
PIPE * a BARS SHALL BE EQUALLY SPACED IN GRATE FOR REFERENCE ONLY
l
lProject\Project Data\Sheet_Fi

V NOT TO EXCEED 8" CENTER TO CENTER


D/24 OR LESS THAN 6" CENTER TO CENTER.
Not Official Bid Document
PLAN
D

45
INLET GRATE DETAIL
(SEE "HEADWALL DETAILS", DRAWING NO. 8, FOR DIMENSIONS) Contact Horrocks Engineers

BEVEL DETAIL T: (208) 463-4197

For Official Bid Documents


IOutfal
H:\!2012\BE-332-1209 FEMA I

DESIGNED DATE PROJECT NO.

SCALE WARNING 9th STREET OUTFALL ITD STD N/A BE-332-1209


5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
NTS Nampa, ID 83687 FEMA II STORMWATER DRAINAGE PROJECT KDH 11/15/2012 7 OF 9
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
CHECKED
REV DATE BY DESCRIPTION MEASURE 1" THEN HEADWALL DETAILS
REVISIONS N/A DRAWING IS NOT TO SCALE 7
TLH 12/03/2012
C * b MAX. 2’-0" * b MAX. 2’-0"

2" MIN.
SPACING SPACING
H-1A H-1A
W-1A

* b * b CONCRETE TABLE
H-1B

W -2
H-1B CONCRETE (C.Y.)

W -2
W-2 NOMINAL

W -2
W -2

W -2
SIZE WINGS
H-1B & FLOOR LIP TOTAL
DIA. (IN.)

2" MIN.
BCKWL.
H-1B H-1B
36 1.0 1.0 0.3 2.3
METAL REINFORCEMENT TABLE
H-1A H-1A
BAR
MARK LOCATION SKETCH
SIZE

* b W -1C

L-2
W -1B
W -1A

W -1A

L-2
L-2
F-1 FLOOR NO. 4
L-1
8:08:48 AM

TOP & BOTTOM


L-1 OF INLET NO. 4 SEE NOTE NO. 3
LIP IN FLOOR

SECTION C-C
HORIZ. IN TOP
ELEVATION

0
OF WING WALL
H-1A NO. 4 C

13
& IN FLOOR
2" MIN. * b ADDITIONAL BARS NEEDED WHEN

2" MIN.
BACK WALL
SPACE IS GREATER THAN 2’-0"
H-1A
2" MIN.
2" MIN.

HORIZ. IN

H
WING WALL * b MAX. 2’-0"

-
W -1B
PIPE

1B
H-1B BETWEEN SPACING
NO. 4
H-1As’ F-1
GRATE DIMENSION & MATERIALS TABLE
* b W-1C
(PAIRS ONLY) W-1A
IN INCHES

W -1A
W -1A
CULVERT
SIZE DIMENSIONS BAR SIZES

2
DIA. (IN.)

"
A’ * c X Y Z B-1 B-2 B-3 B-4

M
L-1

IN
36 38 56 98 61 1x 1x 1x1x 1xx9

.
EACH SIDE OF
DECEMBER 2012

2" MIN. * c ALLOW "-1" EXTRA BAR


PIPE IN PLAN * b MAX. 2’-0"
LENGTH FOR HOLE FABRICATION
0

W-1A BACKWALL, NO. 4 SPACING


9

FLOOR, & BAR LOCATION DETAILS


0
9

INLET LIP

HEADWALL DIMENSION TABLE


0

NOMINAL
9

IN INCHES
IN FLOOR, & SIZE NOTES
W-1B NO. 4 DIA. (IN.)
INLET LIP D/24 A B H L M N P Q U V

36 1 39 42 47 58 51 47 54 56 37 123
1. CAST-IN-PLACE HEADWALLS SHALL CONFORM TO SECTION
0
9

703 - CAST IN PLACE CONCRETE, OF THE CURRENT IDAHO


IN FLOOR, & STANDARD FOR PUBLIC WORK CONSTRUCTION (ISPWC) SPECIFICATIONS.
W-1C NO. 4
INLET LIP
_004.dgn

2. THE METAL REINFORCEMENT SHALL BE NO. 4 BARS. ALL


METAL REINFORCEMENT TABLE
REINFORCEMENT SHALL HAVE A MINIMUM CONCRETE COVER OF
PIPE SIZE DIAMETER (IN.) 2" AND 3" MINIMUM COVER IF CAST AGAINST EARTH.
es\332-1209_hydtl

VERTICAL BAR 36 3. ALL EDGES TO HAVE " CHAMFER OR TOOLED EDGES.


L-2 IN FLOOR, & NO. 4 NO./LGTH.
4. ALL PIPE CULVERTS WITH A CONCRETE HEADWALL SHALL
INLET LIP
F-1 1 83 HAVE THE INLET HEADWALLS BEVELED.
H-1A 2 158
5. THE METAL FOR THE GRATE SHALL MEET THE REQUIREMENTS
H-1B 4 58
OF ASTM A 36. WELDING OF THE METAL GRATE SHALL MEET
l
lProject\Project Data\Sheet_Fi

L-1 2 119 THE REQUIREMENTS OF THE AMERICAN WELDING SOCIETY


VERTICAL IN 2
W-2 NO. 4 L-2 19 D1.1. GRATES NEED NOT BE
WING WALLS
2 114 PAINTED OR GALVANIZED.
W-1A
FOR REFERENCE ONLY
W-1B 1 62
6. NOT TO SCALE.
W-1C 2 43

W-2 6 51
Not Official Bid Document
TOT. WT. 89 lbs.
Contact Horrocks Engineers
IOutfal

T: (208) 463-4197
H:\!2012\BE-332-1209 FEMA I

For Official Bid Documents

DESIGNED DATE PROJECT NO.

SCALE WARNING 9th STREET OUTFALL ITD STD N/A BE-332-1209


5700 East Franklin Rd.
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
NTS Nampa, ID 83687 FEMA II STORMWATER DRAINAGE PROJECT KDH 11/15/2012 8 OF 9
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
CHECKED
REV DATE BY DESCRIPTION MEASURE 1" THEN HEADWALL DETAILS
REVISIONS N/A DRAWING IS NOT TO SCALE 8
TLH 12/03/2012
2
1
S
U

3 CONSTRUCTI
ON DETOUR SI
GNI
NG
18 18
18 W20-2B
Do 10 48" X 48"
wnRi
v 2 DETOUR
erRoa
ROAD
9 d 16 1 CLOSED
W20-3B AHEAD
48" X 48"
500 FT
15
17 17 DIKE BYPASS D-3A(o)
ROAD
20 36" X 18"
17
26
14 DIKE BYPASS ROAD
DIKE BYPASS
ROAD D-3A(o)
DIKE BYPASS
ROAD D-3A(o)
13
8:08:50 AM

(US 12) CLOSED 4 36" X 18" 5 36" X 18"


d 3 DETOUR DETOUR
lRoa AHEAD USE M4-9L M4-9R
ai
tona 30"X 24" 30"X 24"
12
Rece
r ALTERNATE ROUTE

aland 23
dusr
ti SC-1
n
I 72" X 48"

U
4 DIKE BYPASS D-3A(o) DIKE BYPASS D-3A(o) DIKE BYPASS D-3A(o)

S
ROAD ROAD
17 36" X 18" 36" X 18" ROAD
36" X 18"
8

-1
18 2 7 5 6 M4-8 7 M4-8 M6-3(o)
DE
TOUR DE
TOUR

2
6 24" X 12" 24" X 12" 21"X 15"

/D
M5-1L M5-1R
8 25 21"X 15" 21"X 15"
10

i
19

ke
8
16
Bridge Street 24
DE
TOUR
M4-8
DE
TOUR
M4-8
DE
TOUR
M4-8
5 B 24" X 12" 24" X 12" 24" X 12"
8 1
DSt 7 yp 9 WEST M3-4
10 WEST M3-4
11 EAST M3-4
reet as 24" X 12" 24" X 12" 24" X 12"
8 s M1-4 M1-4 M1-4
3 13 6 R
oa 12 24" X 24"
12 24" X 24"
12 24" X 24"
d 24
M5-1L M5-1L M5-1L
4 21" X 15" 21" X 15" 21" X 15"
FOR REFERENCE ONLY
eet

1
r
h St
DECEMBER 2012

Not Official Bid Document 5 DE


TOUR
M4-8
24" X 12"
DE
TOUR M4-8
DE
TOUR M4-8

eet
24" X 12" 24" X 12"
7
15t

M3-4 M3-2 M3-2


8 12 EAST 13 EAST 14 EAST
24" X 12"
Contact Horrocks Engineers 24" X 12" 24" X 12"

r
25

h St
M1-4 M1-4 M1-4
8
Mai
nSt
12 24" X 24"
M5-1L
12 24" X 24" 12 24" X 24"
M6-1 M6-1
T: (208) 463-4197 ree

5t
t 21" X 15" 21" X 15" 21" X 15"
22
22 2
8
For Official Bid Documents

eet
20
M4-8 M4-8 M4-8
4 DE
TOUR DE
TOUR 24" X 12"
DE
TOUR 24" X 12"
24" X 12"

r
h St
21 15 WEST M3-4 16 WEST M3-4
17 EAST M3-2
24" X 12" 24" X 12" 24" X 12"
M1-4 M1-4 M1-4
NOTES

18t
2 14 12 24" X 24" 12 24" X 24"
M6-1
12 24" X 24"
M6-3

eet
M6-1
21" X 15" 21" X 15"
_001.dgn

21" X 15"
1. THE CLOSURE AS SHOWN SHALL NOT EXCEED

eet
12

r
h St
TWO WEEKS TOTAL TIME.

r
es\332-1209_trafcntl

verAvenue

21stSt
8t
END END
2. WHILE THE US-12/DIKE BYPASS ROAD IS CLOSED, DE
TOUR M4-8 G20-5 G20-5
17 DETOUR DETOUR
24" X 12" 30" X 24" 30" X 24"
MAIN STREET MUST BE PAVED WITH ALL LANES M3-4 M3-4 M3-4
16th Avenue 18 WEST 19 20
OPEN TO TRAFFIC. NO WORK SHALL BE DONE ON 24" X 12" WEST 24" X 12" EAST 24" X 12"

US-12 AND MAIN STREET CONCURRENTLY. WORK S M1-4 M1-4 M1-4


ou
t
hw 14
12 24" X 24"
M6-3 12
24" X 24"
12
24" X 24"
SHALL BE COORDINATED WITH THE 13TH STREET
Snake Ri

AND DELSOL LANE OUTFALLS PROJECT. ay 21" X 15"


l

17 26 13
lProject\Project Data\Sheet_Fi

B 12
ri
dg
3. THIS TRAFFIC CONTROL PLAN IS FOR THE e 17
DETOUR
M4-10L
DETOUR
M4-10R

Th
DIKE BYPASS
STORMWATER DRAINAGE OUTFALL PROJECT D-3A(o) 48" x 18" 48" x 18"
ROAD ROAD CLOSED ROAD CLOSED
36" x 18" 0.25 MILES AHEAD 0.70 MILES AHEAD
21 22 R11-3 23 R11-3

ai
WHICH INCLUDES 13th STREET, DELSOL LANE, END G20-5
LOCAL TRAFFIC ONLY LOCAL TRAFFIC ONLY

60" x 30" 60" x 30"

nR
DETOUR 30" X 24"
AND 9th STREET OUTFALLS.
Br

TYPE III TYPE III


yd

BARRICADE BARRICADE

oa
DE
TOUR
M4-8 14 LEGEND
en

24" X 12" R11-2

d
26 13 48" X 30"
M3-4
26 EAST SIGN
C

24" X 12" ROAD


an

ROAD W20-3B
M1-4 3 24 CLOSED
IOutfal

CLOSED 25
BARRICADE 48" X 48"
12 24" X 24"
yo

1000 FT
M5-1L
n

21" X 15"
H:\!2012\BE-332-1209 FEMA I

DIRECTION OF TRAVEL TYPE III BARRICADES


R
oa
d

DESIGNED DATE PROJECT NO.

5700 East Franklin Rd.


9th STREET OUTFALL KDH 11/15/2012 BE-332-1209
HORIZONTAL 0 1/2 1 DRAWN DATE SHEET NO.
Suite 160
NTS Nampa, ID 83687 FEMA STORMWATER DRAINAGE PROJECT BRS 11/15/2012 9 OF 9
IF THIS BAR DOES NOT
VERTICAL
(208) 463-4197 DATE DRAWING NO.
CHECKED
REV DATE BY DESCRIPTION MEASURE 1" THEN TRAFFIC CONTROL
N/A DRAWING IS NOT TO SCALE 9
TLH 12/03/2012

You might also like