You are on page 1of 3

®

CONCRESIVE 1315
Low viscosity epoxy resin with long pot life for crack injection

Description Standards
CONCRESIVE 1315 is a two-component, low CONCRESIVE 1315 meets requirements of ASTM
viscosity epoxy resin based crack injection resin C881, Type 1 & 4, Grade 1, Class B & C
system, with long mixed pot life designed for sealing
cracks in concrete and restoring its structural integrity. Specification Clause
The two-component epoxy injection resin shall be
Uses CONCRESIVE 1315, low viscosity resin system having
CONCRESIVE 1315 is recommended for grouting of viscosity less than 350 cps at ambient temperatures.
0.1 mm to 10 mm wide cracks, cold joints and other The injection resin shall be high strength and shall
such undesirable voids in structural elements, which develop compressive strength in excess of 55 MPa at
are threatening the structural integrity or water 1 day & 65 MPa at 7 days. The product shall exceed
tightness. Applications include: 55 MPa in flexural strength at 7 days and shall exceed
■ Cold joints between subsequent pours of 15 MPa in slant sheer bond strength. The product
concrete. shall have minimum pot life of 30 minutes at ambient
■ Stabilised cracks in structural elements. temperatures. The injection resin shall comply with
■ Unfilled voids behind tiles, stone facades. ASTM C881, Type 1 & 4, Grade 1, Class B &C. The
■ Gap behind the steel plate for epoxy plate injection resin must have pass rating for shrinkage test
bonding. as per ASTM C881 and shall be impermeable.

Advantages Directions for use


■ Excellent bond strength restores structural Injection can be effected through ports that are glued
integrity over the crack opening or through nipples fixed in
■ High elastic modulus ensures effective transfer of holes drilled on the crack. The intervals at which the
stresses at bond interface ports or nipples are fixed depend on the severity and
extent of crack and the type of structure.
■ Low viscosity – effective penetration of even 0.1
mm cracks
Surface Preparation
■ Long pot life enables single line pumping. Correct and high quality preparation is critical for
■ Pre proportioned to give consistent performance. optimum performance.
■ High HDT helps sustaining repair effectiveness
even at high service temperature. Cracks or cold joints: Clean the concrete surface, 2
■ Resistance to creep even at high service cm on either side of the crack or joint, free from dust,
temperatures. fungus, curing membrane and other such
contaminants or if necessary, remove the
Typical properties contaminated layer. Vacuum free from dust. If using
Aspect : Pale yellow liquid nipples for injection, drill 10mm diameter, 50mm deep
Mix density : 1.05 Kg/litre holes at predetermined locations. Use pneumatic drills
Mixing Ratio, by weight : 77 : 23 underwater. Ensure the holes are vacuumed before
Viscosity : 270±50 cps at 25°C fixing nipples.
Pot Life : 50 Minutes at 25°C
: 30 Minutes at 40°C
Use CONCRESIVE 2200i to glue the ports on cracks
Tack free time : 6½ Hours at 25°C
or fix the nipples in holes.
Compressive Strength : 65 MPa at 24 Hours
(ASTM C579) : 70 MPa at 7 Days
The frequency of ports or the nipples depends on the
Flexural Strength : 45 MPa at 24 Hours
crack severity and the nature of the structure but with
(BS 6319, Part 3) : 55 MPa at 7 Days
maximum centre -to-centre distance of 1000mm.
Tensile Strength (ASTM D638) : 18 MPa at 7 Days
If the crack runs through the section of more than
Slant Shear Bond Strength : 18 MPa at 7 Days
500mm thick structural elements, ports / nipples may
(ASTM C882)
be required on both the faces of the elements.
Shrinkage, (ASTM C881) : Passes
Seal the whole length of crack opening using
V.O.C. : < 1.5 %
CONCRESIVE 2200i
Full Chemical Cure : 7 Days at 25°C

Page 1 of 3
Other applications: For epoxy plate bonding, fix Coverage
injection nipples into the pre-drilled holes on the plate The quantity of CONCRESIVE 1315 required is
and seal all the gaps around the plate using dependent on the total volume of the void to be
CONCRESIVE 2200i. grouted, absorption of the substrate, loss and
wastage.
To fill voids behind tiles, stone facade etc., drill holes
to reach the location of void and fix nipples. At least 2 Packaging
holes should be drilled to grout each void. Available in 1 & 4 litre packs

Mixing Storage and Shelf life


Being a small pack, hand mixing is possible. Mix the Store under cover, out of direct sunlight and protect
entire contents of both Base and Hardener containers from extremes of temperature. In tropical climates the
to avoid batching errors. product must be stored in an air-conditioned
environment.
Placing
Place the mixed resin system into cracks or joints on Shelf life is 12 months when stored as above.
horizontal surfaces by ponding (gravity grouting) or
injection and on vertical or overhead surfaces by Failure to comply with the recommended storage
injection. conditions may result in premature deterioration of the
product or packaging. For specific storage advice
To grout by gravity build a bund on either side of the please consult BASF's Technical Services
crack and pond the mixed CONCRESIVE 1315. Department.
Scrape out the resin left over after 2-3 hours.
To grout by injection use a low pressure, air operated Safety precautions
injection equipment or hand operated cartridge gun As with all chemical products, care should be taken
depending on the location & size of the crack. during use and storage to avoid contact with eyes,
mouth, skin and foodstuffs (which can also be tainted
Inject into the crack or joint starting from the widest with vapour until product fully cured or dried). Treat
part if it is a horizontal surface or from the lowest point splashes to eyes and skin immediately. If accidentally
if it is a vertical surface. ingested, seek immediate medical attention. Keep
away from children and animals. Reseal containers
Inject in each port or nipple (keeping all others closed
after use. Do not reuse containers for storage of
except the next immediate one). When the resin starts
consumable item. For further information refer to the
issuing out of the next port/nipple, close it and
material safety data sheet. MSDS available on demand
continue injection until the pressure can be
or on BASF construction chemicals web site.
maintained. After maintaining the pressure for 1 to 5
minutes to allow for total penetration, close the port
Note
and then disconnect the pump. Continue the process
until all the ports or nipples are similarly injected. All BASF Technical Data Sheets are updated on
regular basis; it is the user's responsibility, to obtain
24 hours after the injection remove all the nipples or the most recent issue.
ports and fill in the resulting cavities with Field services where provided, does not constitute
CONCRESIVE 2200i. supervisory responsibility, for additional information
contact your local BASF representative.
Equipment
Disclaimer
Injection: Hand operated cartridge-type gun or air Whilst any information contained herein is true,
operated (pressure pot type) injection equipment. accurate and represents our best knowledge and
experience, no warranty is given or implied with any
Cleaning: Clean tools and equipment first with rags, recommendations made by us, our representatives or
then wipe off using a suitable solvent such as distributors, as the conditions of use and the
CLEANING SOLVENT NO. 2. competence of any labour involved in the application
are beyond our control.
TDS Ref. No. : Ccrx1315/03/0307
BASF Construction Chemicals (India) Private Limited
C-68, MIDC, Thane Belapur Road, Turbhe, Navi Mumbai - 400 613
India
Tel: +91 22 27619992/3, Fax: +91 22 27619242
e-mail: basfcc@vsnl.net www.basf-cc.co.in Page 2 of 3
TDS Ref. No. : Ccrx1315/03/0307
BASF Construction Chemicals (India) Private Limited
C-68, MIDC, Thane Belapur Road, Turbhe, Navi Mumbai - 400 613
India
Tel: +91 22 27619992/3, Fax: +91 22 27619242
e-mail: basfcc@vsnl.net www.basf-cc.co.in Page 3 of 3