liquid-cooled
For tough environment
High-performance converters
siemens.com/sinamics-s120
Low voltage DC Medium voltage
AC AC
For basic applications For demanding applications For basic servo For sophisticated applications For basic and sophisticated For applications with high power ratings
applications applications
SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS SINAMICS
G110 G110D G120P G120D G120C G120 G130/G150 S110 S120 S150 DCM GL150 / GM150 / SM150 / SL150
V/f control/FCC/
Servo Closed-loop speed/
V/f control V/f control/FCC vector control V/f control/FCC/vector control with and without encoder V/f control/vector control/servo control V/f control/vector control
control torque control
without encoder
0.55 – 6 kW – 30 MW
0.12 – 3 kW 0.75 – 7,5 kW 0.37 – 90 kW 0.75 – 7.5 kW 0.37 – 250 kW 75 – 2700 kW 0.12 – 90 kW 0.12 – 4500 kW 75 – 1200 kW 0.8 – 120 MW
18.5 kW
SINAMICS –
the optimum drive for every task
The drive family for drive solutions that are fit for the future
SINAMICS S120 liquid-cooled – Independent of the ambient air Liquid-cooled SINAMICS S120 –
the alternative for tough ambient Advantages at a glance
conditions The thermal power loss of SINAMICS S120
units can be extremely effectively dissi- •• Highest power density through
Liquid-cooled SINAMICS S120 chassis pated to the cooling liquid. This means efficient cooling
units are predestined for tough conditions. that hermetically sealed electrical cabinets •• Predestined for use where space is
High degrees of protection can be easily can be easily implemented in degree of tight
implemented. This means that they can protection IP54 or higher. This protects •• High degrees of protection can be
confidently handle dirty and aggressive the drive unit from dusty and aggressive easily implemented
ambient air. When space is tight, the 60 % air – but the same is also true for humidi- •• Perfectly suitable for dusty and
smaller footprint pays off when compared ty, spray water or salt-laden sea air in aggressive ambient air
to air-cooled versions. As a result of the marine applications. Even high ambient •• Permits modular machine concepts
lower envelope dimensions, new modular temperatures are less critical when com- •• Quiet and low maintenance
machine concepts can be implemented. pared to air-cooled drive units, as it is •• Electrical rooms do not have to be
But this isn’t all – the liquid-cooled drive essentially the cooling water temperature climate-controlled
systems are especially quiet, efficient that defines the thermal load. At the same •• Additional cost-saving potential by
and require little maintenance. In many time, the temperature inside the elec- recovering heat
applications, the heat recovery provides trical room does not increase. For Ex p
additional cost-saving potential. The hazardous zones, the inside of the cabinet
cooling water that is heated up can be can be pressurized to prevent the ingress
used for process heat, heating or water of explosive gases.
for general usage.
Compact, low maintenance
and highly versatile
Up to 60 % smaller footprint makes these drive units predestined for as a free-of-charge heating source for
drive applications where quiet equipment process heat, heating or water for gen-
The liquid-cooled version with its ex- is mandatory, for example in cruise ships eral usage. With such a system, the
tremely compact design is the optimum and production workstations close the normal heating goes into the dormant
choice where space is at a premium drive systems. Further, the drive does mode when the drive is operational.
(ships, offshore platforms) or where the not have a fan, which means there is no High energy-saving potential is especially
drive system is mounted in the driven wearing part to fail, therefore increasing obtained if warm water is required for
machine. When compared to an air- the reliability of the drive and in turn the the production process – for example in
cooled unit with the same power rating, overall plant availability. paper production. The cost savings for
it has an up to 60 % smaller footprint, heating and warm water for general
because the water-cooled drive converter Climate control is not required usage in production and the neighboring
requires significantly less surrounding office buildings have a positive impact on
construction as a result of the more in- For liquid-cooled versions, almost all of the wallet. This is the reason that these
tensive cooling. If the drive units require the thermal power loss is dissipated drive units often pay for themselves in
less space, then the electrical room can through the cooling medium – therefore less than two years.
also be dimensioned smaller – which in the temperature around the drive con-
turn reduces construction costs. verter hardly increases. This means that Range of power ratings
expensive climate control systems can be
Quiet and lower maintenance eliminated – an important factor when The power ratings of liquid-cooled
retrofitting and modernizing drives. SINAMICS S120 extend up to 1,500 kW.
If cooling water is available anyway, it Even higher ratings can be achieved by
certainly makes sense to also use the Additional cost-saving potential by connecting units in parallel.
water-cooled version at conventional lo- recovering heat
cations. This is because the climate-con-
trolled systems of the room in which the In addition to the cost savings as a result
drive converter is installed require less of the efficient cooling concept, there is
equipment and power. For typically only also the possibility of recovering heat.
52 db (A), no additional noise-damping The cooling water that is heated up as
measures are required. This feature part of the cooling process can be used
Sophisticated cooling system Often the ideal sector solution such as cement plants, mining operations,
coal-fired power stations – and printing
The compact design and the high effi- The liquid-cooled concept offers signifi- shops. Applications in the food and
ciency of the liquid-cooled SINAMICS S120 cant advantages in the widest range of beverage industry are another prime
are based on a well-conceived cooling sectors. Every single square meter counts example where electrical cabinets located
system. The cooling circuit cools all of in shipbuilding and on offshore platforms. in the production area must be cleaned
the main components such as power In this case, the space-saving design pays using a water jet for hygiene reasons. For
semiconductors, DC link capacitors and off – also due to the fact that the heat applications in tough environments, the
balancing resistors. Only a low quan- generated in the already hot machinery reduced space requirement, the lower
tity of cooling liquid – water with drink- spaces has to be dissipated anyway as costs for controlling the climate of rooms
ing water quality – is required. This is part of the cooling process and transfer- and heat recovery for warm process
because these drive units only require a red to the seawater through a heat ex- water and water for general usage
comparatively low flow rate to achieve an changer. As a result of the hermetically certainly pay off.
adequate cooling effect. Derating is not sealed cabinet, the salt-laden atmosphere
even required when antifreeze is used. cannot come into contact with the drive Cabinet units in a liquid-cooled version
unit electronics. For plastics machines –
Application-based standard such as extruders and injection molding SINAMICS S120 drives in the liquid-cooled
machines –, the drives are directly mount- version are also available as cabinet
There is a complete range of components ed in the machine. For these types of units. These are designed for the specific
available for the liquid-cooled SINAMICS applications, the liquid-cooled SINAMICS requirements and represent a tailored all-
S120. The standard as well as type-tested S120 permits modular machine concepts in-one solution for each and every drive
components can be adapted to the spe- as a result of its compact design. The application.
cific requirements as required and com- process industry is also predestined for
bined to create the optimum solution for this type of drive solution where a her-
the individual application. The supple- metically sealed cabinet solution makes
mentary components such as cooling sense because of the prevailing chemical-
system and piping can be easily integrat- ly aggressive atmospheres. Other seg-
ed. Liquid-cooled SINAMICS S120 drive ments where this drive solution is ideal
units can also be mounted horizontally. include plants with high levels of dust –
SINAMICS S120 liquid-cooled
Availiable range of units
Siemens AG Subject to change without prior notice The information provided in this brochure contains merely
Industry Sector Order No.: E20001-A180-P570-V1-7600 general descriptions or characteristics of performance which
in actual case of use do not always apply as described or
Large Drives DISPO 21503
which may change as a result of further development of the
P.O. Box 47 43 MK.LD.XX.SISX.52.2.01 WS 11113. products. An obligation to provide the respective characteris-
90025 Nuremberg Printed in Germany tics shall only exist if expressly agreed in the terms of contract.
GERMANY © Siemens AG 2011
All product designations could be trademarks or product
names of Siemens AG or other companies which, if used by
third parties, could infringe the rights of their owners.