You are on page 1of 4

日立造船㈱

Standard
calculation Engineering sheet 環境・ソリューション本部
設計部 設計総括(ヨセカ)
Checki
Approval Created
Equipment name ng
Heat exchanger capacity calculation
Waste heat for high-temperature water
utilization
equipment 10/25/2019
Heat exchanger for high temperature water Quantity: 1
Exchange
heat Q= Required heat quantity×Margin ratio Type:Shell & tube
quantity
Q MJ/h  = 10050 × 1.3 = 13065 ≒ 13065 MJ/h

Hot water
Circulation water quantity
F=Q/(to-ti)/4.1868= 208.0 ≒ 209 m3/h Inlet temperatur 80
Log average (ts-to)-(td-ti) Outlet temperat 95
ΔT=
Temperature difference ts-to td ts Steam condition
ln
Calculation formula

td-ti 134 ### Designed / General use


ΔT℃ to Pressur / 0.4 MPa
#MACRO? 95
=
### ti Tempera / 165 ℃
ln
(134-80) 80 (Saturated temp
### ℃)
Steam enthalpy
= ### ℃
h"= ### kJ/kg
Condensate enthalpy
Overall heat transfer coefficient
K= 4,187 kJ/m2h℃とする。 h'= ### kJ/kg
Material

Heat transfer area


S=Q/(ΔT×K)= ### ≒ ### m 2
Heating pipe:
Amount of steam
G=Q/(h"-h')= ### ≒ ### kg/h Steam chamber:
Hot water tank Valid 35 m 、Dimensions 3

Note Hot water tank capacity=amount of hot


209water
×10/60=
circulated×storage
35 ≒ 35 time=
m3
Heat exchanger for hot water Quantity:1
Exchange
heat Q= Required heat quantity × Margin ratio Type: Suction heater
quantity
Q MJ/h  = 10050 × 1.3 = 13065 ≒ 13065 MJ/h Shell & tube
Amount of
Hot water

water F=Q/(to-ti)/4.1868= 208.0 ≒ 208 m3/h Inlet temp.(ti) 80


circulated
Log average (ts-to)-(td-ti) Outlet temp.(to 95
ΔT=
Temp. difference ts-to td ts Steam condition
ln
Calculation formula

td-ti ### ### Designed / General use


ΔT℃ to Pressur / 0.4 MPa
#MACRO? 95
=
### ti Tempera / 165 ℃
ln
### 80 (Saturated temp
### ℃)
Steam enthalpy
= ### ℃
h"= ### kJ/kg
Condensate enthalpy
C Overall heat K= 4,187 kJ/m2h℃ h'= ### kJ/kg

Material
Heat transfer area
S=Q/(ΔT×K)= ### ≒ ### m2 Heating pipe:
Amount of steam
G=Q/(h"-h')= ### ≒ ### kg/h Steam chamber:
Hot water tank Valid 35 m 、Dimensions
3

Note Hot water tank capacity=amount of hot


208water
×10/60=
circulated×storage
35 ≒ 35 time=
m3
日立造船㈱
Standard
calculation Engineering sheet 環境・ソリューション本部
設計部 設計総括(ヨセカ)
Approv Checki Create
Equipment name al ng d by
Heat exchanger capacity calculation
Waste heat
utilization
for in-house hot water supply/heating
equipment 10/25/2019
Heat exchanger for in -house hot water supply Quantity: 1
Hot water supply F
q= maximum hot water quantity of an hour (according to ba Type:Suction heater
F ㎥/h = 4.54 × 1.2 = 5.448 ≒ 5.4 ㎥/h

Hot water
Heat exchange quantity
Q=F×(to-ti)×4.1868≒
Q 1695.654 MJ/h Inlet temp.(ti 5 ℃
Log average (ts-ti)-(td-to) Outlet temp.( 80 ℃
ΔT=
Temp. difference ts-ti td ts Steam condition
ln
td-to ### #MACRO? Designed
General
/ use
Calculation formula

ΔT℃ to Press / 0.7 MPa


#MACRO? 80
=
### ti Temp / 200 ℃
ln
### 5 (Saturated t ### ℃)
Steam enthalpy
= ### ℃
h"= ### kJ/kg
Condensate enthalpy
Overall heat
transfer K= 4,187 kJ/㎡h℃ h'= ### kJ/kg
co-efficient

Material
Heat transfer areaS=Q/(ΔT×K)= ### ≒ ### ㎡ Heating pipe:
Steam quantity G=Q/(h"-h')= ### ≒ ### kg/h Steam chamber:
Hot water tank Valid 3 ㎥、Dimensions
Note Hot water tank capacity=amount of hot water
5.4 circulated×Storage
×30/60= time=
2.7 ≒ 3 ㎥
Heat exchanger for in-house heating Quantity: 1
Exchange heat Q=required heat quantity (according to balance calculations)× Type: Suction heater
Q MJ/h  = × 1.2 = 0 ≒ 0 MJ/h Shell & tube
Hot water

Circulated water quantity


F=Q/(to-ti)×4.1868= 0.0 ≒ 0 m3/h Inlet temp.(ti 55 ℃
Log average (ts-ti)-(td-to) Outlet temp.( 65 ℃
ΔT=
Temp. difference ts-ti td ts Steam condition
ln
td-to ### #MACRO? Designed/ General use
Calculation formula

ΔT℃ to Press / 0.5 MPa


#MACRO? 65
=
### ti temp / 200 ℃
ln
### 55 ted temp. ts= ### ℃)
Steam enthalpy
= ### ℃
h"= ### kJ/kg
Condensate enthalpy
Overall heat
transfer K= 4,187 kJ/㎡h℃ h'= ### kJ/kg
co-efficient
Material

Heat transfer areaS=Q/(ΔT×K)= ### ≒ ### ㎡ Heating pipe:


Steam quantity G=Q/(h"-h')= ### ≒ ### kg/h Steam chamber:
Hot water tank Valid 0 ㎥、Dimensions
Note 0 ×10/60=
Hot water tank capacity=circulated hot water quantity×storage time= 0 ≒ 0 ㎥


General use

You might also like