You are on page 1of 1

Building Better Business

PRODUCT BULLETIN

February 2, 2018

Update Guide for Platform Software on Pre-production CPB539 Boards

Purpose of this guide

This guide is aimed at users who have PSS 5000 systems where the The following procedure describes how to bring your system up to a
CPB539 boards run the software: Rootfs vers. 799-01-103 or earlier. level where all the latest software releases (except PSS Applications)
Before these systems can be updated using the standard update pro- are running.
cess/procedures, it is necessary to bring them into a state where they Note: PSS Application software cannot be updated unless you purchase
use the Rootfs version 799-01-104. an update or have a valid Software Maintenance Agreement.

Note: If the file names of any of the software packages on your system contain the letter “t”, do not continue with the update.
Contact Doms (support@doms.dk) and they will tell you how to make the software updates.

Preparations Update Procedure

Before you start, make sure that you can access to the Doms Down- 1. Use menu 5.2 Software Update to install 799-61-104.
load Center (https://downloadcenter.doms.com). 2. Use menu 5.8.1 System Reboot to reboot the system.
1. Download the following software package versions: 3. Use menu 5.2 Software Update to install the latest release of
• CPB539 Rootfs: 799-61-104 CPB539 Rootfs 799-61-xxx and then reboot the system again.
And the latest versions for: 4. Install the latest version of the FCC Web Application 900-01-xxx.
• CPB539 Rootfs: 799-61-xxx
• FCC Web Appl: 900-01-xxx 5. Install the latest release of CPB539 U-Boot 467-01-xxx and then
• CPB539 U-Boot: 467-01-xxx reboot the system. (Systems with Rootfs 799-61-109 or later will
• PSS Manager: 469-01-xxx reboot automatically when necessary).

2. Finalize all the transactions on the site & close all the forecourt 6. Install the latest version of the PSS Manager 469-01-xxx
devices. 7. If necessary, use menu 5.1. Backup/Restore to restore the PSS
3. Use menu 5.1. Backup/Restore to make a backup of the current Setup and PSS Configuration.
PSS Setup & PSS Configuration. 8. Open the forecourt devices for normal operation.

Doms ApS, Formervangen 28, 2600 Glostrup, Denmark


806002/01

Tel.: +45 4329 9490 I Fax.: +45 4329 9484


www.doms.com I sales@doms.dk