You are on page 1of 3

BOOK II

PART 4 TECHNICAL REQUIREMENT


Section 4.3 General Technical Requirements
Sub-Section 4.3.17 Fuel Analysis

TABLE OF CONTENT

BOOK II

PART 4 TECHNICAL REQUIREMENT


SECTION 4.3 GENERAL TECHNICAL REQUIREMENTS

SUB-SECTION 4.3.17 FUEL ANALYSIS

4.3.17 FUEL ANALYSIS................................................................................................1


4.3.17.1 GENERAL.........................................................................................1
4.3.17.2 FUEL ANALYSIS...............................................................................1
4.3.17.3 COAL CHARACTERISTICS..............................................................2

Revision 0 Sub-Section 4.3.17 - i Lontar Extension CFSPP (1 x 315 MW)


BOOK II
PART 4 TECHNICAL REQUIREMENT
Section 4.3 General Technical Requirements
Sub-Section 4.3.17 Fuel Analysis

4.3.17 FUEL ANALYSIS

4.3.17.1 GENERAL

The Coal Fired Power Plant and its accessories furnished under this
contract shall be designed to perform satisfactorily burning coal
(bituminous, sub bituminous or lignite) and light oil fuel or the range of
values indicated.

The guaranteed performance shall be based on this fuel analysis. If the


Bidder requires further data on coal and light oil fuel to confirm his design,
he shall conduct the additional tests at his own expense.

4.3.17.2 FUEL ANALYSIS

Fuel analyses specified herein, are preliminary and provided to the Bidder
for his reference.

When a detailed analysis of coal (bituminous, sub bituminous or lignite) and


light oil fuel is available and confirmed by the Owner, the subject analysis
will be forwarded to the Bidder.

In case the Bidder requires any other item to be covered by the fuel and
analysis compared to those listed below, the Bidder must state that in the
Proposal.

Light Oil (HSD) Specification

No. Component Unit Value

1. Specified gravity 15/15 ºC - 0.847 or more


2. Viscosity at 30 ºC cst 5.2 or more
3. Viscosity at 100 ºC cst 1.0 or more
4. Pour Point ºC - .5 or less
5. Flash Point ºC 50 or more
6. Sulphur Content % wt Max 1.2
7. Water Content % wt 0.02
8. Sodium ppm 1.90
9. Potassium cst 2.40
10. Vanadium ppm < 0.5 ppm
11. Lead ppm -
12. Low Heating Value kCal/kg 10.140
13. Ash Content % wt Trace

Note: LFO (HSD) analysis for reference only

Revision 0 Sub-Section 4.3.17 - 1 Lontar Extension CFSPP (1 x 315 MW)


BOOK II
PART 4 TECHNICAL REQUIREMENT
Section 4.3 General Technical Requirements
Sub-Section 4.3.17 Fuel Analysis

4.3.17.3 COAL CHARACTERISTICS

All equipment/system (including Boiler, Electrostatic Precipitator, Coal &


Ash Handling) shall be designed based on the following Coal. The
preliminary data of the coal characteristic are as follows:

Range
Parameter Typical
Minimum Maximum
Proximate Analysis (% as received)
Total Moisture 25 38 35
Inherent Moisture 13.8 25 18
Ash 3.3 6 5
Volatile Matter 27.9 40 35
Fixed Carbon 23 41 30
Specific Energy (as received)
High Heating Value (kCal/kg) 3900 4700 4200
Ultimate Analysis (% dry ash free)
Carbon 65 80 68.57
Hydrogen 3 5.9 5.16
Nitrogen 0.54 1.2 1.18
Oxygen 12 30 24.76
Sulphur 0.25 0.50 0.40
Ash Analysis (%)
2
SiO2 60 16
3
AI2O3 52 9
4.7
Fe2O3 52.5 36
0.02
TiO2 4.1 0.48
0.2
Mn3O4 8.8 4
0.8
CaO 27.7 19.7
0.02
MgO 32.6 10
0.05
Na2O 4.12 0.18
0.1
K2O 2.4 1.3
0.03
P2O5 0.8 0.51
0.2
SO3 24.6 2.83
Ash Fusion Temperature (0C) Reducing Reducing Reducing
I.D.T. (deformation) 1120 1150
S.T. (softening) 1200
H.T. (hemispherical) 1250
F.T. (fluid) 1300

Slagging Index >Medium Low


Fouling Index >Medium Medium
Hardgrove Grindability Index (HGI) 45 65 55

The Minimum and Maximum Range of Design Coal shall be used to design the Boiler.

The Typical Design Coal shall be used for Performance Test Guarantee purposes.

Revision 0 Sub-Section 4.3.17 - 2 Lontar Extension CFSPP (1 x 315 MW)