You are on page 1of 2

Cooling Water Requirement-NEO

SR. NO Equipment Descprtion Tag No. CWS/CWR Line Size (inch) Flow Requirement , m3/hr Remarks
1 Al.Hyd.Water Removal Reactor R-1010 CWS 3 CW Line size is 10 " and reduce to 3" at R-1010
2 Al.Hyd.Water Removal Reactor R-1010 CWR 3 CW Line size is 10 " and reduce to 3" at R-1010
3 Hydrolysis Reactor R-1009 CWS 3 CW Line size is 10 " and reduce to 3" at R-1010
4 Hydrolysis Reactor R-1009 CWR 3 CW Line size is 10 " and reduce to 3" at R-1010
5 Catalyst Preparation Reactor R-1005 steam header CWS 2 CW line size is 10" and reduce to 2" at R-1005
6 Catalyst Preparation Reactor R-1005 steam header CWR 2 CW line size is 10" and reduce to 2" at R-1005
7 Catalyst Preparation Reactor R-1005 CWS 1 CW line size is 10" and reduce to 1" at R-1005
8 Catalyst Preparation Reactor R-1005 CWR 1 CW line size is 10" and reduce to 1" at R-1005
9 Al.Hyd.Water Removal Reactor R-1010 CWS 1 CW line size is 3" and reduce to 1" at R-1010
10 Al.Hyd.Water Removal Reactor R-1010 CWR 1 CW line size is 3" and reduce to 1" at R-1010
11 Feed Pump P-1127 CWS 1 CW line size is 10" and reduce to 1" at P-1127
12 Feed Pump P-1127 CWR 1 CW line size is 10" and reduce to 1" at P-1127
13 Catalyst Preparation Pump P-1008 CWS 1.5 CW line size is 10" and reduce to 1.5" at P-1008
14 Catalyst Preparation Pump P-1008 CWR 1.5 CW line size is 10" and reduce to 1.5" at P-1008
15 Pump P-1061A CWS 1 CW line size is 3" and reduce to 1" at P-1061A
16 High Boiler Cooler E-1037 CWS 3 CW Line size is 10 " and reduce to 3" at E-1037
17 High Boiler Cooler E-1037 CWR 3 CW Line size is 10 " and reduce to 3" at E-1037
18 OT Cooler E-1145 CWS 3 CW Line size is 10 " and reduce to 3" at E-1045
19 OT Cooler E-1145 CWR 3 CW Line size is 10 " and reduce to 3" at E-1045
20 shell and tube heat exchanger E-2226 CWS 10 CW Line size is 16 " and reduce to 10" at E-2226
21 shell and tube heat exchanger E-2226 CWR 10 CW Line size is 16" and reduce to 10" at E-2226
22 Product MEA Cooler E-1038 CWS 3 CW Line size is 10 " and reduce to 3" at E-1038
23 Product MEA Cooler E-1038 CWR 3 CW Line size is 10 " and reduce to 3" at E-1038
24 Distilled OT Cooler E-1027 CWS 1.5 CW Line size is 10 " and reduce to 1.5" at E-1027
25 Distilled OT Cooler E-1027 CWR 1.5 CW Line size is 10 " and reduce to 1.5" at E-1027
26 Water Condenser E-1017 CWS 3 CW Line size is 6 " and reduce to 3" at E-1017
27 Water Condenser E-1017 CWR 3 CW Line size is 6 " and reduce to 3" at E-1017
28 OT Vent Condenser E-1026 CWS 2 CW Line size is 3" and reduce to 2" at E-1026
29 OT Vent Condenser E-1026 CWR 2 CW Line size is 3" and reduce to 2" at E-1026
30 MEA Vent Condenser E-1036 CWS 2 CW Line size is 3" and reduce to 2" at E-1036
31 MEA Vent Condenser E-1036 CWR 2 CW Line size is 3" and reduce to 2" at E-1036
32 OT Condenser E-1025 CWS 2 CW Line size is 6" and reduce to 2" at E-1025
33 OT Condenser E-1025 CWR 2 CW Line size is 3" and reduce to 2" at E-1025
34 MEA Condenser E-1035 CWS 2 CW Line size is 3" and reduce to 2" at E-1035
35 MEA Condenser E-1035 CWR 2 CW Line size is 3" and reduce to 2" at E-1035
36 Condenser E-1006 CWS 3 CW Line size is 10 " and reduce to 3" at E-1006
37 Condenser E-1006 CWR 3 CW Line size is 10 " and reduce to 3" at E-1006
38 Heat Exchanger E-1094 CWS 1 CW Line size is 6 " and reduce to 1" at E-1094
39 Heat Exchanger E-1094 CWR 1 CW Line size is 6 " and reduce to 1" at E-1094
40 Heat Exchanger E-1093 CWS 3 CW Line size is 6 " and reduce to 3" at E-1093
41 Heat Exchanger E-1093 CWR 3 CW Line size is 6 " and reduce to 3" at E-1093
42 shell and tube heat exchanger E-2405 CWS 10 CW Line size is 16" and reduce to 10" at E-2405
43 shell and tube heat exchanger E-2405 CWR 10 CW Line size is 16" and reduce to 10" at E-2405
44 shell and tube heat exchanger E-2207 CWS 6 CW Line size is 10 " and reduce to 6" at E-2207
45 shell and tube heat exchanger E-2207 CWR 6 CW Line size is 10 " and reduce to 6" at E-2207
46 Heat Exchanger E-1165 CWS 3 CW Line size is 6 " and reduce to 3" at E-1165
47 Heat Exchanger E-1165 CWR 3 CW Line size is 6 " and reduce to 3" at E-1165
48 Scrubber CWS 3 CW Line size is 10 " and reduce to 3" at Scrubber
49 Scrubber CWR 3 CW Line size is 10 " and reduce to 3" at Scrubber
CW Line size is 6 " and reduce to 1" at 1st Stage
50 CWS
1st stage condesate 1 Condensate
CW Line size is 6 " and reduce to 1" at 1st Stage
51 CWR
1st stage condesate 1 Condensate
52 Heat Exchanger E-1135 CWS 3 CW Line size is 6 " and reduce to 3" at E-1135
53 Heat Exchanger E-1135 CWR 3 CW Line size is 10 " and reduce to 3" at E-1135
Cooling Water Requirement-NEO
SR. NO Equipment Descprtion Tag No. CWS/CWR Line Size (inch) Flow Requirement , m3/hr Remarks
1 SEAL COOLER PHE PHE-1 CWS 2
2 SEAL COOLER PHE PHE-1 CWR 1.5
3 PRIMARY SURFACE CONDENSER-01 PSC1 CWS 3 For MEE 85 m3/hr flow required
85 m3/hr Δ T = 5 deg C
4 PRIMARY SURFACE CONDENSER-01 PSC1 CWR 3 Pressure = 2.5 kg/cm2
5 SECONDARY SURFACE CONDENSER SSC1 CWS 3
6 SECONDARY SURFACE CONDENSER SSC1 CWR 3

7 CWS 3 For ATFD 12 m3/hr flow required


PRIMARY SURFACE CONDENSER-02 PSC2 20 m3/hr Δ T = 5 deg C
8 PRIMARY SURFACE CONDENSER-02 PSC2 CWR 4 Pressure = 2.5 kg/cm2
9 FLASH CONDENSER 3E-0102 CWS 3 For Stripper 58 m3/hr flow required
58 m3/hr Δ T = 5 deg C
10 FLASH CONDENSER 3E-0102 CWR 4 Pressure = 2.5 kg/cm2

You might also like