You are on page 1of 8

SICHARGE UC

The Flexible Solution for


the Future Urban Mobility

siemens.com/eMobility
2|

Energizing the world


of utility vehicles
Many towns, communities and companies your electricity bill and most important,
have already discovered the benefits of provides you with the safety that all your
an electrified fleet for their public buses, vehicles are always available when you need
delivery or waste removal trucks. Successful them. Furthermore, it has to seamlessly
projects can be found in numerous places integrate in any existing environment. Small
around the world, and we can expect an footprints in highly frequented areas and a
exponential growth of such installations as design which supports your brand need to
both electric utility vehicles and available be considered.
charging infrastructures are now adapted
With the SICHARGE UC family, Siemens
to perfectly fit the needs.
provides such a set of building blocks which
The future-oriented charging setup takes adapts to the various requirements and
care of a diverse mix of vehicles, considers restrictions you encounter in energizing
restrictions in power supply setup, optimizes your fleet now and in the future.

Sample of a bus depot


configuration with
various components
of the SICHARGE UC
family

The Sicharge UC Charging Center Pantograph Technical


Introduction
family & Frontend & Hood data
|3

The SICHARGE UC family


Providing you always with the best fitting hard- and software for your specific
needs is our mission. For this, you can freely choose from the components of the
SICHARGE UC family in its various power classes. One or multiple Charging Centers
are always the core of the system as it contains the AC grid connection and the
DC power electronics for your charging purposes.

Cloud based
software solution
including Load
Managemant

e.g. 150 kW max. e.g. 600 kW max.

Up to AC
1000 V

DC

Grid Battery Charging Up to 5 Frontends


Pantograph or Hood
connection storage Center with cable connection

Depot charging
The easiest way to connect to an electric Frontends which you can install flexibly
vehicle is via a charging cable from the within your charging setup. As this cable
Charging Center. As space is valuable in connection requires some user interaction,
many public places and logistic sites, you and is dedicated for longer charging times,
might want to distribute the DC power from we generally see this installed in bus or
the Charging Centers via up to 5 additional logistic depots.

Opportunity charging
Also used in depots but often dedicated possibilities via a mast mounted Panto-
for short-term opportunity charging, we graph or respectively via fix contact rails
see the use of Pantograph solutions, installed in the mast or roof mounted
either installed on the vehicle or as part Hood. Either of such option is again
of the off-board infrastructure. The powered by the Charging Center and if
SICHARGE UC family provides solutions you want to combine frontends and
also for these automated connection Pantograph, you also have this flexibility.

The Sicharge UC Charging Center Pantograph Technical


Introduction
family & Frontend & Hood data
4|

The SICHARGE UC family


Charging Center High degree of
protection IP54 against
The Charging Center is the dust and spray water Multilingual 7‘‘ outdoor
core of your system. It touchscreen display at an
contains the charging ergonomic height,
controller, the DC convert- accessible and easy to read
ers and optionally a direct – also in bright sunlight
cable connection to the
Covered plug holder
vehicle. Several other (optional)
vehicle connections like the
cable based Frontend,
Emergency stop button
inverted Pantograph and
Cable holder for
Hood can be powered by convenient and clean
this unit. operation C3 painted for outdoor
usage
Power cable with
comfortable length for
rough environments
Large doors for easy
maintainance access

Frontend
Inclined rain protection
The cable connected hood directs water to
Frontend of the UC family the rear
is installed close to the Multilingual 7‘‘ outdoor
vehicles connection with a touchscreen display at
small footprint and elegant an ergonomic height,
design. High degree of accessible and easy to read
protection IP54 against – also in bright sunlight
For investment and space dust and spray water
optimization, several
Frontends can be powered Cable holder for convenient
in sequence by a single and clean operation
Charging Center.
Covered plug holder
(optional)
Power cable for application
in rough environments
with comfortable length

Cable optionally cooled


for up to 400 A Air ventilation slots for the
continuous, 500 A max. liquid cooled cable

The Sicharge UC Charging Center Pantograph Technical


Introduction
family & Frontend & Hood data
|5

Easy maintenance
Cantilever arm
Inverted Pantograph access through the
door, 230 V sockets
urban design inside
Inverted Pantograph
The inverted Pantograph is your
fully automated option to connect LED signal lamp to
to your fleet e.g. on feeding WLAN antenna for the indicate the status
opportunities along the route. secured and reliable Wi-Fi of charging
communication to
This “urban design” was created charging infrastructure
to accommodate modern urban Baseplate for safe
architecture. Robust charger mast to attachment to the
carry the Pantograph foundation

Cantilever arms available Stabilizing tension rod Inverted Pantograph


in short or long with a industrial design
big variety of colors to fit
individual environment With similar features as the urban
of the city design, the industrial design of
Easy maintenance the mast has its advantages of a
Inverted Pantograph access through the moduar installation as well as
door, 230 V sockets optimized cost.
WLAN antenna for the inside
secured and reliable Wi-Fi
communication to
charging infrastructure
Baseplate for safe
LED signal lamp to indicate attachment to the
the status of charging foundation

Robust charger mast

Mast mounted Hood


For electic vehicles with
integrated Pantograph, the Cantilever arm
Hood is the connecting
counter­part. You have the
Lightweight mast and
choice of a single as well as a Connection Hood with simple architecture
double design for sequential insulated 4-pole contact easy to setup
charging.

Baseplate for safe


attachment to the
foundation

The Sicharge UC Charging Center Pantograph Technical


Introduction
family & Frontend & Hood data
6|

Technical data
SICHARGE UC
Charging Center
The Charging Center is delivered 100-percent
factory-tested, including controllers, the device
as a whole and, optionally, communication
with the Frontend

Technical data Siemens eBus / eUtility Charging Center


Power class 50 100 150 225 300 450 600
Vehicle interface
CCS cable on Charging Center × × × - - - -
Frontend or Charging Center
× × - - - - -
with GB/T cable
Frontend with CCS cable × × × - - - -
up to
Frontend with cooled CCS cable × × × × × -
15 min
Mast mounted Hood × × × × × × ×
Mast mounted (inverted)
× × × × × × ×
Pantograph
Nominal input
Voltage 3 phases + PEN, 400 Vac ±10%
Current at nominal voltage
79 198 317 475 633 950 1267
per phase, A
Frequency, Hz 50/60
Power factor (cos phi) > 0.98
DC output
Power (max.), kW 50 125 200 300 400 600 800
Power (rated at 750 Vdc), kW 38 94 150 225 300 450 600
Current (max.), A 50 125 200 300 400 600 800
Voltage (range), Vdc 10 ... 1000
Efficiency factor η (at load 100%) 96% ... 97%
Environmental conditions
Operating Temperature -25 ºC ... +45 ºC (extended upon request)
Mechanical specifications
Operational environment Indoor and outdoor
Protection enclosure IP54, IK10
Casing material Galvanized steel, painted, C3
Color Main housing: RAL 9006 – White aluminium; roof and base: RAL 9017 – Traffic black matt
  915 × 1000 × 1000 ×
Overall dimensions W x D x H (mm) 700 × 800 × 1800 1000 × 1000 × 1400 × 2000 2400 × 2800 ×
2000 2000 2000
Approx. weight, kg 700 1000 1400 2000 2600 4000 5200
General specifications
Charge control unit Siemens SIMATIC S7
Local user interface Siemens SIPLUS HMI TP700
Network connection Ethernet interface / 3G and 4G / WLAN
Communications protocol OCPP 1.6 (J-SON)
Charging standards EN 61851-1/23/24, ISO 15118 (DIN 70121)*
EMC standards EN 55016-2-1 & -3; EN 61000-4-2 & -3 & -4 & -5 & -6
Compliance CE declaration
* Complies with ISO15118-1 standard use-cases, further use-cases being implemented

The Sicharge UC Charging Center Pantograph Technical


Introduction
family & Frontend & Hood data
|7

SICHARGE UC SICHARGE UC SICHARGE UC


Frontend Inverted Pantograph Mast mounted Hood
Cooled cables as an option Inverted Pantograph is a The mast mounted Hood is
can be installed in the same plug-and-play solution for designed for the efficient
Frontend housing, increas- top-down Pantograph connection of any ISO 15118
ing charging power up to charging – each mast bottom-up Pantograph
400 A continuous (500 A arrives fully preinstalled, system. Each mast arrives
for 15 min) electrically checked and fully preinstalled, electrically
equipped with the Panto- checked and equipped with
graph. the contact Hood.

Technical data Siemens eBus / eUtility Charging


Frontend & masts SICHARGE UC SICHARGE UC SICHARGE UC
Frontend Inverted Pantograph Mast mounted Hood
Design variants UD ID ID-E ID ID-T
Urban Industrial Industrial Industrial Industrial
design design design- design design,
extended T-shape
Connector
Frontend with CCS or GB/T cable × - - - - -
Mast mounted Hood - - - - × ×
Mast mounted (inverted) Pantograph - × × × - -
DC output
Power (max.) standard, kW 200 800 800
Power (max.) liquid-cooled cable
500 n/a n/a
(option), kW
Power (rated at 750 Vdc) standard, kW 150 600 600
Current (max.) standard, A 200 800 800
Current (max.) liquid-cooled cable
500 n/a n/a
(option), A
Voltage (range), Vdc 10…1000
Mechanical specifications
Protection IP54, IK10
Height, installed (mm) 1765 5805 6573 6573 5000 5000
Road clearance (mm) n/a 4550 to 4650 4635 4635
Cantilever length (mm) n/a 3955 4200 5200 3500 7000
Approx. distance mast to curb (mm) n/a 1400 1400 2400 1900 1900
Footprint on sidewalk (mm) 600 × 300 940 × 315 1300 × 330 1300 × 330 350 × 300 350 × 300
Operating range Pantograph (mm) n/a 900 n/a
Approx. weight, kg 100 / 150* 1975 1870 2300 900 1100
Main housing:
RAL 9006 – White
aluminium;
Color RAL 9006 – White aluminium
roof and base:
RAL 9017 – Traffic
black matt
Galvanized
Galvanized
steel with
Material powder coated Galvanized steel, painted, min. C3
fiber glass
steel
panel
General specifications
Communication standard PLC WiFi IEEE 802.11a PLC
Number of possible connectors
up to 5 1 1 2
(sequential charging)
*1
 00 kg with standard 200 A cable; 150 kg with liquid cooled 500 A cable
n/a = not applicable

The Sicharge UC Charging Center Pantograph Technical


Introduction
family & Frontend & Hood data
Siemens AG
Smart Infrastructure
Distribution Systems

Mozartstrasse 31c
91052 Erlangen, Germany

© 10/2019, Siemens AG

Subject to changes and errors. The information given


in this document only contains general descriptions
and/or performance features which may not always
specifically reflect those described, or which may
undergo modification in the course of further
development of the products. The requested
performance features are binding only when they
are expressly agreed upon in the concluded contract.

You might also like