Tank Agitator
by Allied on July 1, 2013
Equipment Information
Reported Defect
Figure 2: 1x Turning Speed and Harmonics Indicating Looseness
Problem Statement:
There is looseness in the vibration spectrum. Examination of the coupling reveals that
the coupling is cocked on the shaft.
Recommendation:
Check coupling for signs of wear, such as cracks. Repair or replace as needed. Check
shaft keys for proper length and size. Line shaft key was 180 degrees offset. Check
motor for soft foot; laser align motor to gearbox. Tighten all bolts to proper torque.
Follow-up Findings
In June of 2010, vibration data was collected on the blend tank agitator. Looseness was
seen in the vibration spectrum, as indicated in Figure 2 by a frequency peak at 1x
turning speed and several harmonics. A work order was issued to check the condition of
the coupling. While time was charged to this work order, no comments were attached.
A change in the work order’s status triggered vibration data to again be acquired and the
looseness could still be seen in the vibration spectrum. The coupling was superficially
examined by the analyst while the asset was running, with no problems noted. The work
order was closed and the analyst continued investigating for another source of the
looseness.
On December 8, 2010, vibration data was again collected on the blend tank agitator, and
the data suggested that the amount of looseness had increased. The coupling was again
examined and this time it appeared to be cocked on the shaft and wobbling. The actual
wobble of the coupling due to it being cocked could be seen in the time waveform, as
shown in Figure 3. Another work order was issued to repair or replace the coupling as
needed.
Examination of the coupling revealed that components were in pieces and worn
(Figures 4 through 9). While still operational, the coupling would have soon failed
catastrophically.
Figure 4: Coupling Cocked on the Asset Shafts
Good Work
Ken Nygaard