You are on page 1of 1

- +

ACC START Ignition


RUN Switch
LOCK
OFF

Fuse

Battery Starter Relay


Junction
Box

2
3
Start
Inhibit Transmission P
Switch Range 1 PCM
R 2
Manual Selector N D
Transmission

4
Pull-in
Starter Motor Coil Hold
Coil
Solenoid

Operation Where to check


1). Fused power flows from battery junction to ignition 1). Check for power at igntion switch (1). If none,
switch. check fuse.
2). User turns key to START and power flows to control coil 2). Check for power (2) and ground (3) at starter
of starter relay. relay with key in START position
3). PCM determines that passive anti-theft system (PATS) has 3). Check transmission range selector for
received proper key and provides ground to starter relay continuitiy. Connector known for corrosion
control coil. problems.
4). Starter relay switches power to solenoid coils on starter 4). Check for battery on the (4) grey wire at
motor. Magnetic force pulls contact closed to switch battery starter motor with key in START position.
power to starter motor
© 2012 Rick Muscoplat