You are on page 1of 1

Technical Specification for Foundation Works

SECTION 102 BAGIAN 102


SPECIFIC REQUIREMENT FOR KEBUTUHAN SPESIFIK UNTUK
FOUNDATION WORK PEKERJAAN PONDASI

1. Precast Prestressed Spun Pile:


1. Tiang Pancang Pra-tarik Pra-cetak :
The pile diameters are Ø 600 mm and Ø 500 mm, driven to -16m up to
-20 m from the ground surface. Diameter tiang pancang adalah Ø 600 mm dan Ø 500 mm, dipancang
-16 m sampai -20 m dari permukaan tanah.
2. Allowable load for piles
2. Beban yang diijinkan untuk tiang pancang
2.1 Design vertical load
a. Ø 600 mm = 125 metric tonnes 2.1 Beban vertical desain :
b. Ø 500 mm = 90 metric tonnes a. Ø 600 mm = 125 metrik ton
2.2 Design horizontal load : b. Ø 500 mm = 90 metrik ton
a. Ø 600 mm = 5.5 metric tonnes 2.2 Beban horisontal desain :
b. Ø 500 mm = 4.5 metric tonnes a. Ø 600 mm = 5.5 metrik ton
b. Ø 500 mm = 4.5 metrik ton
3. Proof-load tests
3. Uji Proof-Load
3.1 Tests to be conducted by kentledge method
3.2 Vertical load test: 3.1. Pengujian dilakukan dengan menggunakan metoda kentledge
a. 10 nos Ø 600 mm has to be tested for vertical load of 2 x 125 3.2. Uji beban vertical :
metric tonnes a. 10 nos Ø 600 mm harus diuji untuk beban vertikal 2 x 125
b. 2 nos Ø 500 mm has to be tested for vertical load of 2 x 90 metrik ton
metric tonnes b. 2 nos Ø 500 mm harus diuji untuk baban vertikal 2 x 90
metrik ton
3.3 Horizontal load test 3 3. Uji beban horisontal
a. 1 nos C.600 mm has to be tested for horizontal load of 2 x a. 1 nos Ø.600 mm harus diuji untuk beban horisontal 2 x 5.5
5.5 metric tonnes metrik ton
b. 1 nos 0 500 mm has to be tested for horizontal load of 2 x b. 1 nos Ø 500 mm harus diuji untuk beban horisontal 2 x 4.5
4.5 metric tonnes metrik ton
Test should be stopped If lateral deflection at the head of the Pengujian harus dihentikan jika defleksi lateral di kepala
pile exceeds 12.5 mm. tiang pancang melebihi 12.5 mm.

4. Pile Integrity Testing (PIT) 4. Uji Integritas Tiang Pancang (PIT Test)

To ensure the integrity of the pile 30 Nos of pile has to be tested for Untuk memastikan integritas tiang pancang 30 nos tinang pancang
integrity by the PIT method. harus diuji untuk integritas dengan metoda PIT.

Section 102 Section 102 – Page 1


Specific Requirement for Foundation Work

You might also like