Maximum Flow rate Check valve
Nominal adjustment range*1 Free flow Mass
Model code operating pressure Cracking pressure
diameter L/min kg
MPa {kgf/cm2} L/min MPa {kgf/cm2}
JF -G02- 30-15
JFC -G02- 30-15
¼ Up to 30 30 3.9
21 {210} 0.035 {0.35}
JF -G03-105-16
JFC -G03-105-17
⅜ Up to 105 105 8.3
Note: *1 The minimum control flow rate varies depending on the pressure difference between the inlet and outlet ports. See the valve
differential pressure - minimum control flow rate characteristics for details.
JF-03M Rc⅜
3.2
JF-03M06 ⅜ Rc¾
JF-03M08 Rc1 4.5
Refer to Page S-7 for the dimensions of the sub-plate.
Handling
When controlling a flow rate of 0.2 L/min or less with JF(C)-G02 or 0.5 L/min or less with JF(C)-G03, use the valve in
combination with a line filter with a filtration accuracy of 10 μm or better.
To ensure good pressure compensation performance, maintain a pressure difference of 1 MPa {10 kgf/cm2} minimum between
the inlet and outlet ports.
Seal the O-ring (Part No. 25 in the sectional structural diagram) at the rear of the flow rate adjusting handle with the gasket face.
F-5
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
25
30 30
Flow rate (L/min)
15 20 20
10
10 10
5
0 0 0
0 1 2 3 4 0 3.5 7 10.5 14 17.5 21 0 10 20 30 40 50 60
Scale (Number of revolutions) Valve differential pressure (MPa) {×10 kgf/cm } 2 Fluid temperature (°C)
0.5
60
Flow rate (cm3/min)
0.4
40 0.3
0.2
20
0.1
0 0
0 3.5 7 10.5 14 17.5 21 0 10 20 30
Valve differential pressure (MPa) {×10 kgf/cm2} Flow rate (L/min)
JF(C)-G03
Scale - Flow rate characteristics Valve differential pressure - Fluid temperature - Flow rate characteristics
Pressure difference between inlet and outlet ports: Flow rate characteristics Pressure difference between inlet and outlet ports: 21 MPa {210 kgf/cm2}
21 MPa {210 kgf/cm2} Fluid used: equivalent to ISO VG32
120 120 120
80 80 80
60 60 60
40 40 40
20 20 20
0 0 0
0 1 2 3 4 0 3.5 7 10.5 14 17.5 21 0 10 20 30 40 50 60
Scale (Number of revolutions) Valve differential pressure (MPa) {×10 kgf/cm } 2 Fluid temperature (°C)
500 0.5
Flow rate (cm3/min)
400 0.4
300 0.3
200 0.2
100 0.1
0 0
0 3.5 7 10.5 14 17.5 21 0 20 40 60 80 100
Valve differential pressure (MPa) {×10 kgf/cm2} Flow rate (L/min)
F-6
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
11.2
G
φU
Jumping
φT
prevention stopper
(option code II: N)
φ6
K
9 1
W F
J
11
H
F
8 2
I N
D E
φ45
C
7 3
φR
φS
6 4
5
Dimensions
Model No.
A B C D E F G H J K M N P Q R S T U V W
JF (C) -G02 95.3 9.5 76.2 53.8 38.1 101.6 9.5 82.6 52.4 47.1 86 62 50 42 14 22 14 9 9.5 6.5
JF (C) -G03 124 11.2 101.6 74.9 50.8 124 11.2 101.6 86.6 62.8 108 84 71.5 63.5 23 34 17.5 11 20.6 6
23 24 21 1 9 11 27 10 21 6 22 26 7 8
18
16
28
20
17
19
15
25 3 4 2 29 30 5 21 21 12 14 13
F-7