KPa abs
ATING CONDITIONS
ERS CHARACTERISTICS
Intermittent
ONSTRUCTION
SEAL
COUPLINGS (Driver-Blower)
Purchaser
NO.
AIR BLOWERS DATA SHEET REV. 0
SHEET:2 of 3
AIR BLOWERS DATA SHEET
53 MATERIALS OF CONSTRUCTION SURFACE PREPARATION AND PAINT
54 Casing Cast Iron Manufacturer's standard
55 Impeller Aluminium Other
56 Shaft Stainless Steel Blower Driver Base Plate
57 Gear VTA Surface preparatVTA VTA VTA
58 Drive & driven pullVTA Primer VTA VTA VTA
59 Safety valve VTA Finish coat VTA VTA VTA
60 Frame Finish color VTA VTA VTA
Carbon Steel
61 Shipment
62 BASE PLATE Domestic Export Export boxing required
63 By blower manufacturer Outdoor storage more than 6 months
64 Suitable for epoxy grout Spare rotor assembly packaged for :
65 Extended for Blower + Driver Horizontal storage Vertical storage
66 Subsole plates by blower manufacturer Type of shipping preparation
67 Drain rim WEIGHTS
68 Drain pan Blower kg VTA
69 Earth boss Driver kg VTA
70 Material Carbon steel Housing kg VTA
71 Lifting lugs Base plate kg VTA
72 Spread bars Total kg VTA
73 INSTRUMENTATION ACCESSORIES
74
mounting
Provision
winding
Blower
Driver
✘
only
for
76 ✘ Silencers
77 ✘ Safety valve
78 ✘
Sound proof housing (if required)
79 Brg.Thermometer ✘ Check valve
80 Temp. Sensors ### ✘ Ant vibratory pads
81 Vib. Sensors ✘ V- belt
82 Temp. Switches ✘ Base frame
83 Vib. Switches ✘ Belt guard
84 Temp. Transmetter ✘ Foundation bolts
85 Vib. Transmetter ✘ Motor pulley & blower pulley
86 Flat surface required
87 Resistance temperature detector INSPECTION AND TEST (1 & 2)
88 Monitors and cables ✘ Hydrostatic
89 Vendor recommendations ✘ Mechanical Perfor
90 Instruments Data Sheet ✘ Electrical Performa
91 ✘ Noise test
92 Suction Dicharge ✘ Vibration Test
93 Pressure gauge ✘ Complet unit test
94 Pressure transmitter Notes:
95 Pressure switch 1/
2/ Approval
Tests shallofbe
Manufacturer
conducted inProcedure
accordance is required.
96 Instruments Data Sheet with the specified standards approved by
97 Control Panel the
3/ AirPurchaser
filters shall be provided of sufficient
98 Control monitor capacities to furnish at all times an air
99 Junction box supply sufficiently free from
### dust to prevent damage to blowers and clogging of the diffuser system used. Air
### Filter shall be a heavy duty type suitable for Oman environment.
### 4/ Automated lub-oil circulation with water cooling system shall be provided.
### 5/ The Supplier shall ensure that the plant room shall not rise more than 10°C above
the ambient temperature when the maximum numbers of aeration and grit blowers
are in operation.
5/ The Supplier shall ensure that the plant room shall not rise more than 10°C above
### the ambient temperature when the maximum numbers of aeration and grit blowers
are in operation.
NO.
AIR BLOWERS DATA SHEET REV. 0
SHEET:3 of 3
1 ELECTRIC MOTOR DATA SHEET
2 DESIGN DATA
3 Motor data
4 Make VTA Type VTA Rated power VTA Kw
5 No of poles VTA Nos Rated voltage 415 V Frequency ### 50 Hz
6 Efficiency VTA Power facto VTA Rotation VTA RPM
7 Duty Continuous ✘ Intermittent Duty cycle S1 Cycle duration fac- %
9 Start up Direct ✘ Star/delta Auto transformer ✘ OthersSoft starter
10 Cooling Fan
11 Lubrication Pumped fluid Ring oil Oil mist Constant level oiler
12 External Oil flood Grease
13 Execution and degree of protecEnclosureIP 56 Execution - Terminal bo IP 56
14 Supply data
15 Electrical area classification Class Safe Group Division
16 Phases 3 Ph Operation voltage ( 415 V ± % Frequency 50 Hz ± %
17 Combined variation of V an ± %
18 Neutral point Solidly earthed Earthed through resistance
19 Min. voltage on terminals at st %UE %
20 Data of driven machine (blower)
21 Type - Stalling torque (TR)
22 I = MR2 - KgM2 Thrust - Kg
23 PERFORMANCE AND COSTRUCTION DATA
24 Manufacturer and construction type -
25 Service Factor - Rated current - A
26 Rated torque (TN) - NM Start up current (ma - P.U.± - %
27 Minimum torque (TU)- PU Full load Current - P.U.
28 Load 2/4 3/4 4/4 Locked Locked rotor current - P.U.
29 Efficiency - - - - Locked rotor time (TI) P.U.
30 Power factor - - - - Maximum torque (TB) - P.U.
31 No. of successive starts - Full load speed - RPM
32 Overall noise level - dBA Specific start up time (TAS -) s
33 Lubricant - Locked rotor time (TRB) - s
34 Bearings Tye - Number Insulation class F
35 Radial - / - Temperature rise Class B
36 Thrust - / - Lubricating interval - hours
37 Rotation direction with phase time sequenL.O.A -
38 connections L1 - U, L2 - V, L3 - - Motor fan yes
39 Earth cable terminal -
40 Terminal box Quantity/entry diamet - Nos / - mm Position -
41 Entry type ✘ Cable gland Cone ThreadedThread typ -
42 Enclosure dimensions - I = MR 2
- KgM 2
54
RPM