You are on page 1of 5

TEST FACILITIES AT DQA(N)

Name of the Sl. Test Facility Range Remarks


Establishment and No.
address, name of
Nodal officer and
contact No.
(1) (2) (3) (4) (5)
Chief Quality 1 Dry Heat (High Temperature) Amb to 3000C JSS 55555
Assurance +/-3o C<100oC IS 9000,
Establishment (WE) Chamber Size: 1x1x1 m +/-5o C>100oC DEF 133,
Jalahalli Camp Road MIL 810 &
Yashwanthpur PO Max. Weight & Max. JSS 50101
Bangalore- 560 022 permissible size of test sample
(width X height X depth) (*):
Cdr G 200 kg, 0.5x0.5x0.5m
Subramanyam
2 Damp Heat ( Steady State) 400C+/-2oC JSS 55555
Phone No.: 95%RH(Min) IS 9000,
080-23571176 Extn Chamber Size: 1.5x1.5x1.5m DEF 133 &
125 JSS 50101
E-mail:cqae-bng- Max. Weight & Max.
dgqa@nic.in permissible size of test sample
(width X height X depth) (*):
300 kg, 0.75x0.75x0.75m

3 Damp heat ( Cyclic) / Tropical Amb to JSS 55555


exposure 550C+/-2oC, IS 9000,
95% RH(Min) DEF 133,
Chamber Size: 1.5x1.5x1.5m MIL 810 &
JSS 50101
Max. Weight & Max.
permissible size of test sample
(width X height X depth) (*):
300 kg, 0.75x0.75x0.75m

4 Damp Heat (Moisture Amb to JSS 50101


Resistance) 0 o
65 C+/-2 C,
95% RH(Min)
Chamber Size: 1.5x1.5x1.5m

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
300 kg, 0.75x0.75x0.75m
5 Dry Cold (Low Temperature) Up to – JSS 55555
600C+/-3oC IS 9000,
Chamber Size: 1x1x1m DEF 133,
MIL 810 &
Max. Weight & Max. JSS 50101
permissible size of test sample
(width X height X depth) (*):
300 kg, 0.5x0.5x0.5m

6 Mould Growth / Fungus 29oC+/-1oC JSS 55555


Resistance 90%RH(Min) IS 9000,
DEF 133,
Chamber Size: 1.2x1.2x1.2m MIL 810 &
JSS 50101
Max. Weight & Max.
permissible size of test sample
(width X height X depth) (*):
200 kg, 0.6x0.6x.0.6m

7 Corrosion (Salt) 350C+/-2oC JSS 55555


90 to 95% RH IS 9000,
Chamber Size: 1.5x1.5x1.5m DEF 133,
MIL 810 &
Max. Weight & Max. JSS 50101
permissible size of test sample
(width X height X depth)
(*):500 kg, 0.75x0.75x0.75m

8 Rain 200kPa+/-15% JSS 55555


450 litres +/- IS 9000,
Chamber Size: 2x2x2m 10% per hour DEF 133,
MIL 810 &
Max. Weight & Max. JSS 50101
permissible size of test sample
(width X height X depth)
(*):1000 kg, 1x1x1m

9 Drip Proof 1m from top of JSS 55555


equipment DEF 133,
Chamber Size: 1.0x1.0m JSS 50101

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
NA , 0.75 x 0.75m
10 Contamination 50oC+/-2 o C JSS 55555
DEF 133.
Chamber Size: 1x1x1m

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
200 kg, 0.5x0.5x0.5m

11 Rapid temperature cycling / - 40 to + 1000 JSS 55555


Thermal shock C,+/-2oC IS 9000,
95% RH(Min) DEF 133,
Chamber Size: 1x1x1m MIL 810 &
JSS 50101
Max. Weight & Max.
permissible size of test sample
(width X height X depth) (*):
100 kg, 0.5x0.5x0.5m

12 Shock NSS I & II, JSS 55555


Half Sine
Chamber Size: 0.75x0.75m pulse only
base size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
500 kg for NSS-I & 800 kg for
NSS-II including jig
0.75x0.75x1.0m

13 Vibration ( Manual sweep & 5 to 33 Hz JSS 55555,


Endurance at fixed 0.125 mm DEF 133
frequencies) constant disp.

Chamber Size: 1x1 m base


size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
500 kg including jig 1x1x1 m
14 Vibration 7 to 350 Hz, JSS 50101
( Endurance by sweep) 2G
tolerance in
Chamber Size: 0.15x0.15 m accelerations
base size <150Hz +/-
15%
Max. Weight & Max. >150Hz +/-
permissible size of test sample 25%
(width X height X depth) (*): 2
kg including jig 0.1x0.1x0.1 m

15 Random/Sine Vibration 5 to 2000 Hz, JSS 55555,


100G MIL & DQAN
Chamber Size: 1x1 m base Guideline
size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
400 kg including jig 1x1x1 m

16 Bump Machine 10, 40g, JSS 55555


6, 11 ms IS 9000,
Chamber Size: 1x1 m 1 or 2 bump DEF 133,
base size per sec. JSS 50101

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
250 Kg, including jig
0.75x0.75x0.75 m

17 Bump Machine 0 to 100g, 5 to


20 ms ,1
Chamber Size: 1.3 x 1.3 mtr bump per sec.

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
1000 kgs

18 Ship motion +/- 15 deg


fixed
Chamber Size: 1.2x1.2 m
base size

Max. Weight & Max.


permissible size of test sample
(width X height X depth) (*):
200 kg 0.9x0.9x0.9 m
19 High voltage Break Down 10 KV NES

20 Insulation Up to 1000 V NES


DC

21 Load Tank 40Kw, 3


phase

22 Shock & Vibration 0.7 to 3000 Hz


Measurement System , +600g

23 3 phase Variable Power Supply 0v – 460v AC ,


2000Amp

24 400Hz Variable Frequency 0v – 250v AC,


Supply 40 – 450 Hz

25 Multimeter 750v AC,


1000v DC

26 Lux Meter 0.1mv –


200mv

27 IR Laser Temperature Sensor -20 to +65


Deg

28 Clamp Meter AC/DC 0 – 400 amp,


1000v DC,
750v AC

29 Clamp Meter AC 1000Amp,


750v

(*) - Following tolerances are permissible on the sample size mentioned in Col. (3) above.

(i) +30% of any one side, if only one side of the sample exceeds the maximum
permissible size of the sample.

(ii) +15% of any two sides, if only 2 sides of the sample exceeds the maximum
permissible size of the sample.

(iii) +10% of all three sides, if all the three sides of the sample exceed the
maximum permissible size of the sample.