You are on page 1of 1

CHATTERBOX 10-12-10

10:42am
1 of 1
KeyBeam® 4.506a
kmBeamEngine 4.508e
Materials Database 1197

Member Data
Description: Member Type: Beam Application: Roof
Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: None
Standard Load: Moisture Condition: Dry Building Code: IBC / IRC
Dead Load: 17 PLF Deflection Criteria: L/240 live, L/180 total 0.500" max. LL
Snow Load: 42 PLF Deck Connection: Nailed Member Weight: 43.4 PLF
Filename: KYB1

Other Loads
Type Trib. Dead Other
(Description) Begin End Width Start End Start End Category
Replacement Uniform (PLF) 0' 0.00" 31' 3.00" 716 1059 Snow

3 10 0 23 7 0 3 10 0
1 2

31 3 0

Bearings and Reactions


Location Type Input Length Min Required Gravity Reaction Gravity Uplift
1 3' 10.000" Wall 6.000" 4.775" 28412# --
2 27' 5.000" Wall 6.000" 4.775" 28413# --

Maximum Load Case Reactions


Used for applying point loads (or line loads) to carrying members
Dead Snow
1 11866# 16547#
2 11866# 16547#
Design spans
3' 10.000" (left cant) 23' 7.000" 3' 10.000" (right cant)

Product: 1-3/4" x 23-7/8" x 2.0E WS-LAM LVL 4 ply


Component Member Design has Passed Design Checks.**
Design assumes continuous lateral bracing along the top chord.
Design assumes no lateral bracing along the bottom chord.

Allowable Stress Design


Actual Allowable Capacity Location Loading
Positive Moment 113058.'# 179058.'# 63% 15.62' Total load D+S
Negative Moment 13360.'# 179058.'# 7% 27.42' Total load D+S
Negative Unbrcd 13360.'# 204552.'# 6% 27.42' Cants Only D+S
Shear 17824.# 36517.# 48% 26.24' Total load D+S
Max. Reaction 28413.# 35700.# 79% 27.42' Total load D+S
TL Deflection 0.6960" 1.5722" L/406 15.62' Total load D+S
LL Deflection 0.4053" 0.5000" L/698 15.62' Total load S
TL Defl., Lt. -0.3435" 0.5111" 2L/267 0' Total load D+S
LL Defl., Lt. -0.2001" 0.3833" 2L/459 0' Total load S
TL Defl., Rt. -0.3435" 0.5111" 2L/267 31.25' Total load D+S
LL Defl., Rt. -0.2001" 0.3833" 2L/459 31.25' Total load S
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives

All product names are trademarks of their respective owners


SCOTT MEYER
WAUSAU SUPPLY CO. 1-800-236-1528
Copyright (C)1989-2005 by Keymark Enterprises, LLC. ALL RIGHTS RESERVED.

**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet.
The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.