You are on page 1of 1

NV BONAS MACHINERY SERIES 800 CONTROLLER

HARDWARE CONNECTIONS

The following diagram shows the connections for the full interface version of the S800 controller. The
interface board is accessible under the panel at the rear of the controller.
P2 P3 P9 P8 P4 IO1 IO2 SW3 J1

SW4

SW1

SW2
0v 48v
P1

FO1 FO2 FO3 FO3 P7 J4 J3 J7 J6

P1 Power connection to controller from Jacquard: 48V DC


P2 Data link to Jacquard head 1.
P3 Data link to Jacquard head 2.
P4 Serial link (RS485) to Loom.
P7 CAN link to Loom
P8 Watchdog connection from Jacquard
P9 Resolver connection to Jacquard

J1 Network (Ethernet) RJ45 connector


J3 Loom emergency stop connections
J4 Jacquard emergency stop connections
J6 Loom contactor supply
J7 Jacquard contactor connection

IO1 Loom parallel connections (inputs and outputs)


IO2 Extended Loom parallel connections

FO1 Fibre optic data connection head 1 receiver


FO2 Fibre optic data connection head 1 transmitter
FO3 Fibre optic data connection head 2 receiver
FO4 Fibre optic data connection head 2 transmitter

Note: Remove connector protection caps before installing fibre optic cables

SW1 Controller input source/sink selection


SW2 Input/output voltage selection
SW3 Controller output source/sink selection
SW4 CAN link termination

NOTE: ON SERIAL COMMUNICATION LOOMS, THE INTERFACE CONNECTIONS ARE REDUCED

VERSION 1.00 Page 7