You are on page 1of 2

II.

MATERIALS
Emission Power II:
Apparatus: 1. Same procedure with Emission
1. TRTC software Power I, the only difference is that it
2. SCADA system introduces split before the ST
3. TRTC equipment apparatus.
4. Plates with the thermocouples 2. 1st split is 1 cm
5. Radiation meter 3. 2nd split is 2 cm.
6. Recipient with some water
7. Variable slit
IV. DATA AND RESULTS
Materials: hand gloves (clothed)
Equipment: 30% EMISSION without Split
1. AR-1 Heat radiator Distance Trial 1 Trial 2 Trial 3
2. Apertura (cm) (W/m^2) (W/m^2) (W/m^2)
3. SR 1 Radiometer 10 22 64 65
4. Computer with built-in SCADA
program TRTC 15 29 35 34

III. PROCEDURE 20 29 22 21

25 20 17 18
Emission Power I:
1. Connect the SCADA program TRTC. 30 14 13 13
2. Verify all the temperatures sensors
and the heating resistance have been 35 10 10 11
connected.
3. Fix a distance between the 40 8 7 8
radiometer and the heat source of 10
cm and additional 5cm for another
trial 30% EMISSION with 1st Split (1 cm)
4. Fix a power for the heating surface of Distanc Trial 1 Trial 2 Trial 3
30% power. e (W/m^ (W/m^ (W/m^
5. Wait until the system is stationary (cm) 2) 2) 2)
and the temperature in the 10 10 8 9
resistance reaches an stable value.
Take the measurement that can be 15 6 6 7
seen in the monitor measured in
20 5 4 3
flux(W/m^2)
6. Repeat the previous steps for a 25 3 3 2
distance between radiometer and
resistance of 10cm, 15cm, 20cm, 30 2 2 1
25cm, 30cm, 35cm, 40cm.
7. Repeat the experiment for AR-1=60% 35 2 1 1
40 1 1 1 60% EMISSION with 1st Split (1cm)
Distanc Trial 1 Trial 2 Trial 3
e (W/m^ (W/m^ (W/m^
(cm) 2) 2) 2)
30% EMISSION with 2nd Split (2 cm) 10 211 208 210
Distanc Trial 1 Trial 2 Trial 3
e (W/m^ (W/m^ (W/m^ 15 109 109 108
(cm) 2) 2) 2)
10 21 14 16 20 71 72 71

15 13 9 11 25 52 50 50

20 9 6 8 30 40 40 42

25 7 5 7 35 31 33 31

30 5 4 5 40 20 21 21

35 4 3 4
60% EMISSION with 2nd Split (2cm)
40 3 3 3 Distanc Trial 1 Trial 2 Trial 3
e (W/m^ (W/m^ (W/m^
(cm) 2) 2) 2)
60% EMISSION without Split 10 357 349 353
Distanc Trial 1 Trial 2 Trial 3
e (W/m^ (W/m^ (W/m^ 15 228 192 214
(cm) 2) 2) 2)
10 530 599 598 20 156 124 140

15 402 469 467 25 113 86 108

20 241 263 261 30 96 74 96

25 202 219 220 35 84 68 81

30 133 136 137 40 72 56 67

35 102 111 111

40 84 91 92

You might also like