FLYBACK TRANSFORMER P/N TR-310H PAGE 1/1

SPECIFICATION
1. DIMENSION:

INFOUNLTD

2. SCHEMATIC:

3. SPECIFICAION:
MEAST. ITEM DATA TEST INSTRUMENT/CONDITION
INDUCTANCE L1 22.0 uH ± 15 % LCR METER (1KHZ)
INDUCTANCE L2 18.0 uH ± 15 % LCR METER (1KHZ)
INDUCTANCE L3 1.80 H ± 15 % LCR METER (1KHZ)
RESISTANCE L1 115 mΩ ± 15 % LCR METER (1KHZ)
RESISTANCE L2 140 mΩ ± 15 % LCR METER (1KHZ)
RESISTANCE L3 155.0 KΩ ± 15 % LCR METER (1KHZ)
HI-POT L1. L2 TO L3 5KVAC/3mA/1min INSULATION/PUNCHER/TESTER

Turns Ratio = 286:1

INFORMATION UNLIMITED INC APPROVAL CHECKED WRITTER


WWW.AMAZING1.COM
Sample Circuit Using TR310H MULTPLIER SECTION
1 STAGE FOR 5KV/10ma
+12 INPUT RED
2 stages for 10 kv/5ma
LEAD
4 stages for 20kv/2.5ma
3 amp S1/R10 R2 C20A 5 stages 35 kv 1.5ma
10 500 7 stages 50kv/1ma
T1
R7 Output
47K
+
D20J R7A are carbon or
RI IRF540 D20A
50v 10K silicon
4 8 R3 TPX
C1 1K
100 2 .1 R4 C20J
6 10 Multiplier 500
3
5-6 usec 100 1 5 C6 R30-35 is 5 10 meg R6
C4 Q1
14-15 usec I1 1watt resistors inside
2200 .47PP R5 a plastic tube TRY5
-
35V 250 1K 200ua/10kv
HV RETURN LEAD EXITS FROM BACK OF UNIT
COM BLACK LEAD C2 C3 15 volt AND IS BLACK OR GREEN
.0022 .01

COMMON D12 M1 R8K


EXT EARTH GROUND 1N4937
GREEN LEAD
Oscillator 2KT
0-5
scale

Connect scope to test point TPX.

Adjust R1 to the wave shape shown with


unit connected to a 12 volt 4 amp R28
C17
2.2k
supply. .1
R22
2.2K
Out put voltage should be 45kv RESCAP 1UFD
indicating a current of over 1 ma. Input FREQ=37KHZ R24
current will be 3.5 amps with a power
output in excess of 45 watts! USE .224pp FOR 60-70KHZ 3
+ 1M

LED2 7
6 R23
Q2 I2
4 100KP C19
TIP31
R3 2 .001
1K - R25
1M

Z2 Z1 100KT
1N5225 1N5233
TR310H OC PRI=20.5uH SC=3.5uH R27 3V 6.V
1K CHANGE
TO 3 VOLT
5225