You are on page 1of 76

Pump Division

Pump Product Catalog

Experience In Motion
Pump Supplier to the World
Flowserve is the driving force in the global Product Brands of Distinction
industrial pump marketplace. No other pump
ACEC™ Centrifugal Pumps
company in the world has the depth or breadth
of expertise in the successful application of Aldrich™ Pumps
pre-engineered, engineered, and special purpose
Byron Jackson ® Pumps
pumps and systems.
Calder™ Energy Recovery Devices

Cameron™ Pumps

Durco ® Process Pumps

Flowserve ® Pumps

IDP ® Pumps

INNOMAG ® Sealless Pumps

Lawrence Pumps ®

Niigata Worthington™ Pumps

Pacific ® Pumps

Pleuger ® Pumps

Scienco™ Pumps

Sier-Bath ® Rotary Pumps

TKL™ Pumps

United Centrifugal ® Pumps

Western Land Roller ™ Irrigation Pumps

Wilson-Snyder ® Pumps

Worthington ® Pumps

2 Worthington Simpson™ Pumps


flowserve.com

Pump Designs
Flowserve offers a wide range of complementary
pump types, built to recognized global standards Committed to the Complete Pump
and customer specification. These include: System Life Cycle
• Single-stage process
• Between bearings single-stage For more than two centuries, Flowserve has
• Between bearings multistage served industries requiring solutions that add
value and reduce costs throughout the life
• Vertical
cycle of a pumping system.
• Submersible motor
• Oil and gas
• Positive displacement
• Chemical
• Nuclear
• Power generation
• Specialty
• Water
• General industry
Available Configurations
Flowserve partners
• Sealed and sealless
with customers to
• Axially and radially split respond to the
• Volute and diffuser dynamic business
• Close coupled and spacer coupled conditions that
• Single and double case affect them and to
improve efficiency, maximize throughput and
control process quality. Whether customer needs
involve on-site technical assistance, equipment
upgrades or broader project planning with full
turnkey responsibility, Flowserve delivers
professional, reliable results.

3
A Guide to Flowserve Pumps
The purpose of this publication is to provide a
brief summary of the hundreds of pumps that Oil and Gas
comprise the Flowserve product line. Pump
models are divided into five sections, beginning
with overhung pumps and continuing through Chemical
specialty designs. Each pump is identified by its
formal designation and accompanied by a full-
color cutaway illustration. Applicable engineering Power
standards are listed along with performance
characteristics and key features. The symbols
shown at right are used to identify each pump’s Water Resources
primary market applications.

For more information about Flowserve pumps, visit:


Mining
www.flowserve.com

Pulp and Paper

Primary Metals

General Industry

4
flowserve.com

Table of Contents
Pump Selection Guide.......................................... 6 – 7 Positive Displacement
Product List.............................................................51
Overhung Pumps Gear.........................................................................52
Product List...............................................................9 Screw.......................................................................53
Chemical Process.............................................10 – 15 Reciprocating...........................................................54
API Process......................................................16 – 18
Slurry and Solids Handling............................... 19 – 22 Specialty Products
Industrial Process............................................. 23 – 25 Product List.............................................................57
Nuclear Pumps and Seals.................................58 – 61
Between Bearings Pumps Extreme Temperature Pumps................................... 62
Product List.............................................................27 Others............................................................... 63 – 65
Single Case — Axially Split — Single-Stage........28 – 29
Single Case — Axially Split — Multistage..................30 Additional Information
Single Case — Radially Split — Single-Stage.............31 Introduction.............................................................67
Single Case — Radially Split — Multistage.........32 – 34 Integrated Solutions Group............................... 68 – 69
Double Case...................................................... 35 – 37 Other Flowserve Products........................................ 70
Reference Sources...................................................71
Vertical Pumps
Product List.............................................................39 Index
Wet-Pit..............................................................40 – 41 Product List...................................................... 72 – 73
Double Case......................................................42 – 43
Submersible............................................................. 44
Slurry and Solids Handling...............................45 – 47
Sump................................................................48 – 49 5
Pump Selection Oil and Gas Power Generation
Guide Downstream Upstream
Chemical Processing (Fossil, Renewables,
Nuclear)
and Pipeline

Residuum and Heavy Oil Upgrading


Gas Treating and Sulfur Recovery

Crude, Product and CO2 Pipeline


Heavy Oil, Oil Sands and Shale
Off-sites and Waste Treatment

Volatile Organic Compounds


Water Supply and Treatment

Renewable Fuel Production

Flue Gas Desulfurization


Water and CO2 Injection

Caustic and Chlor-Alkali


Drilling and Production

Condensate Extraction
Boiler Feed Booster
Waste Processing
Slurry Processing
Catalytic Cracking

Pharmaceuticals
Hydrocracking

Gas to Liquids

Cooling Water
Hydrotreating

NGL and LPG

Acid Transfer

Boiler Feed
Distillation

Polymers

Auxiliary
Solvents
FPSO
Pump

LNG
Category Sub-Category
Overhung Chemical Process — X X X X X X X X X X X X X X X X X X
ASME (ANSI), ISO
API Process X X X X X X X X X X X X X X X X X X X X X X X X
Slurry and Solids X X X X X X X X X X X X
Handling
Industrial Process X X X X X X X X X X X X
Between Single Case — X X X X X X X X X X X X X X X X X X X
Bearings Axially Split
Single Case — X X X X X X X X X X X X X X X X X X
Radially Split
Double Case X X X X X X X X X X X X X
Vertical Wet-Pit X X X X X X X X X

Double Case X X X X X X X X X
Deep Well X X X X X X
Submersible Motor
Slurry and X X X X X X X X X
Solids Handling
Sump X X X X X X X X X X
Positive Gear X X X X X X X X
Displace-
ment Screw X X X X X X X X X X X X X

Multiphase X X

Reciprocating X X X X X X X X
Specialty Nuclear Pumps
Products
Nuclear Seals

Cryogenic Pumps X X
Cryogenic Liquid X
Expander
Geothermal
Deep well
Submersible Pump
Hydraulic Decoking X
Systems
Energy Recovery — X X X
Hydroturbine
Energy Recovery —
DWEER
Thruster X X
CVP Concrete X
Volute Pumps
Barge Pump
Molten Salt
VTP Pump
X
X
X
Geothermal Well Services

X
X
Heat Transfer Fluids

X
X
X
X
Molten Salt Transfer

X
X
Transformer Cooling

X
X
X
X
X
X
X
X
X
X
X
X
X
X
Auxiliary Services

X
X
X
X
X
X
X
X
X
X
X
X
X
Nuclear)
(Fossil, Renewables,
Power Generation

Nuclear Service

X
X
X
X
X
X
X
X
X
X

X
X
Desalination

X
X
X
X
X

X
Flood Control

X
X
X
X
X
X
X
Groundwater Development and Irrigation

X
X

X
X
Sewage Collection and Treatment

X
X
X
X
X
X
X

X
Water Supply and Distribution
Water Resources

X
X
X
X
X
X

X
X
X
Water Treatment

X
X
X

X
X
Cooling Water

X
X

X
X
Descaling

X
X
X

X
X
Hydraulic Press

X
X
X

X
Plating, Galvanizing and Other Coatings
Primary Metals

X
X

X
X
Scale Recycle

X
X
X
X

X
X

X
X
X

Dewatering and Water Supply

X
X

X
X

Leaching Acid

X
X

X
X
X
Mining

Primary Processing

X
X
X
X

Slurry Transfer

X
X

X
X

Bleach Chemical
X
X

X
X

X
X

X
X
Boiler Feed
X

X
X
X

X
X

Chemical and Liquor


X

X
X

X
X
Coatings

X
X
X

Digester
Pulp and Paper

X
X
X

X
Paper Stock
X

Shower Pumps
X

X
X
X
X
X

X
X
X
X
X

X
X
Automotive
X

X
X
X
X

X
X
X
X
X

X
X

Agriculture
X

X
X
X
X

X
X
X
X
X
X

X Construction
X

X
Industrial Gases
X

X
X
X
X

X
X
X
X
X
X

X
X

Electronics
X

X
X
X
X
X

Fire Protection
X

X
X
X

X
X
X
X
X
X

X
X

Food Processing
General Industry

X
X
X

X
X
X
X

HVAC
X
X
X

X
X
X
X
X
X

X
X

OEM
X

X
X
Shipping
flowserve.com

X
X
X

X
X
X

Snowmaking
Overhung Pumps flowserve.com
Chemical Process
Mark 3™ ASME Standard 10
Mark 3 Lo-Flo™ 10
Mark 3 Unitized Self-Primer 10
Mark 3 Recessed Impeller 11

Overhung Pumps
Mark 3 In-Line 11
Guardian Magnetic Drive 11
Mark 3 ISO Standard 12
Mark 3 ISO Self-Priming 12
Mark 3 ISO Recessed Impeller 12
Mark 3 ISO Close Coupled 13
CPXV Chemical Sump 13
CPXS Magnetic Drive 13
PolyChemTM GRP 14
PolyChem VGRP 14
PolyChem S-Series 14
PolyChem M-Series 15
Polyshield 15
Polybase 15
API Process
HPX 16
HPXM 16
PHL 16
ERPN 17
PVXM 17
HWMA 17
PVML 18
MSP 18
DSVP 18
Slurry and Solids Handling
M 19
R 19
Titan Slurry™ 19
LC 20
MND 20
MNR 20
FRBH 21
FRBHJC 21
MPT 21
MF 22
MN 22
MSX 22
Industrial Process
D800 23
MEN 23
MENBLOC 23
ME 24
DS 24
SMP 24
SMX 25
F-Line 25
MVE 25

9
Mark 3 ASME Standard Mark 3 Lo-Flo Mark 3 Unitized
Self-Primer
Overhung — Chemical Process

Standards Standards Standards


• ASME (ANSI) B73.1 • ASME (ANSI) B73.1 • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4540 m3/h (20 000 gpm) • Flows to 50 m3/h (220 gpm) • Flows to 320 m3/h (1400 gpm)
• Heads to 215 m (700 ft) • Heads to 300 m (985 ft) • Heads to 120 m (400 ft)
• Pressures to 27 bar (400 psi) • Pressures to 31 bar (450 psi) • Pressures to 20 bar (285 psi)
• Temperatures from -73°C (-100°F) • Temperatures from -73°C (-100°F) • Temperatures to 370°C (700°F)
to 370°C (700°F) to 370°C (700°F) • Static suction lift to 6 m (20 ft)

Features Features Features


• Exclusive reverse vane impeller • Circular, concentric casing • Unitized casing with large priming
• Standard Mark 3A power end • Radial vane impeller chamber, air separator and volute
– External micrometer impeller • Standard Mark 3A power end • Exclusive reverse vane impeller
adjustment mechanism – External micrometer impeller standard; open impeller optional
­­­– Heavy-duty radial and thrust bearings adjustment mechanism • Standard Mark 3A power end
– Double lip oil seals ­­­– Heavy-duty radial and thrust bearings – External micrometer impeller
– Constant level oiler – Double lip oil seals adjustment mechanism
­– Large, reflective sight glass – Constant level oiler ­­­– Heavy-duty radial and thrust bearings
• Choice of lubrication systems ­– Large, reflective sight glass – Double lip oil seals
• Optional ANSI 3A power end with • Choice of lubrication systems – Constant level oiler
lifetime warranty • Optional ANSI 3A power end with ­– Large, reflective sight glass
– Certified clean room assembly lifetime warranty • Choice of lubrication systems
– Inpro/Seal® VBXX isolators – Certified clean room assembly • Optional ANSI 3A power end with
– Magnetic drain plug – Inpro/Seal VBXX isolators lifetime warranty
• SealSentry™ seal chambers – Magnetic drain plug – Certified clean room assembly
• Largest shaft and bearing components • SealSentry seal chambers – Inpro/Seal VBXX isolators
in ANSI standard pumps • Oversized shaft and bearings – Magnetic drain plug
• IPS BeaconTM electronic vibration • IPS Beacon electronic vibration and • SealSentry seal chambers
and temperature condition monitor temperature condition monitor • Oversized shaft and bearings
• IPS Beacon electronic vibration and
Related Configurations Related Configurations temperature condition monitor
• Mark 3 Lo-Flo • Mark 3 ASME Standard
• Mark 3 Unitized Self-Primer • Mark 3 Recessed Impeller Related Configurations
• Mark 3 Recessed Impeller • Mark 3 ASME Standard
• Mark 3 Sealmatic dynamically sealed See Bulletin PS-10-13.
See Bulletin PS-10-13.
® Inpro/Seal is a registered trademark of Inpro/Seal Company.
See Bulletin PS-10-13.
10
Mark 3 Recessed Mark 3 In-Line Guardian
Impeller Magnetic Drive

Overhung — Chemical Process


Standards Standards Standards
• Flowserve • ASME (ANSI) B73.2 • ASME (ANSI) B73.1 dimensions

Operating Parameters Operating Parameters Operating Parameters


• Flows to 455 m3/h (2000 gpm) • Flows to 370 m3/h (1630 gpm) • Flows to 375 m3/h (1650 gpm)
• Heads to 120 m (400 ft) • Heads to 230 m (755 ft) • Heads to 215 m (700 ft)
• Pressures to 20 bar (285 psi) • Pressures to 24 bar (350 psi) • Pressures to 24 bar (350 psi)
• Temperatures from -73°C (-100°F) • Temperatures from -73°C (-100°F) • Temperatures from -73°C (-100°F)
to 370°C (700°F) to 370°C (700°F) to 290°C (550°F)

Features Features Features


• Low shear vortex pumping action • Exclusive reverse vane impeller • Magnetic drive design
• Fractional media contact with • Standard Mark 3A power end • Alloy C-276 containment shell
the impeller – External micrometer impeller • Rare earth magnets
• Standard CD4MCuN impeller adjustment mechanism • Low NPSHR, reverse vane impeller
• Thick-wall wet end components ­­­– Heavy-duty radial and thrust bearings • Casings and impellers interchangeable
suitable for light slurries – Double lip oil seals with sealed configuration
• Standard Mark 3A power end • Optional ANSI 3A power end with • Optimized internal lubrication path
– External micrometer impeller lifetime warranty • Silicon carbide bushings and journals
adjustment mechanism – Certified clean room assembly with double spiral grooves
­­­– Heavy-duty radial and thrust bearings – Inpro/Seal VBXX isolators • Standard and contained back pullout
– Double lip oil seals • SealSentry seal chambers • Options
– Constant level oiler • Unique C-plus motor and pump shaft – Fiber optic leak detection
­– Large, reflective sight glass alignment system – Containment shell temperature
• Optional ANSI 3A power end with • Choice of bearing lubrication probes
lifetime warranty – Regreasable bearings – Process temperature probes
– Certified clean room assembly – Oil mist – External flush plans
– Inpro/Seal VBXX isolators – Permanently lubricated bearings
– Magnetic drain plug Available Configurations
• SealSentry seal chambers Related Configurations • G-Series: -75°C (-100°F) to
• Oversized shaft and bearings • Mark 3 In-Line, recessed impeller 120°C (250°F)
• IPS Beacon electronic vibration and
• H-Series: -120°C (-250°F) to
temperature condition monitor
See Bulletin PS-10-15. 290°C (550°F)
Related Configurations
See Bulletin P-10-14.
• Mark 3 ASME Standard
• Mark 3 Sealmatic, recessed impeller

See Bulletin PS-10-13. 11


Mark 3 ISO Standard Mark 3 ISO Self-Priming Mark 3 ISO Recessed
Impeller
Overhung — Chemical Process

Standards Standards Standards


• ISO 2858 • ISO 2858 • ISO 2858
• ISO 5199 • ISO 5199 • ISO 5199

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1400 m3/h (6160 gpm) • Flows to 100 m3/h (440 gpm) • Flows to 750 m3/h (3300 gpm)
• Heads to 220 m (720 ft) • Heads to 100 m (330 ft) • Heads to 100 m (330 ft)
• Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi)
• Temperatures from -80°C (-110°F) • Temperatures from -80°C (-110°F) • Temperatures from -80°C (-110°F)
to 400°C (752°F) to 400°C (752°F) to 400°C (752°F)

Features Features Features


• Heavy-duty casing with integral foot • One-piece casing with integral priming • Heavy-duty casing with integral foot
and multi-ribbed discharge flange chamber, air separator and volute and multi-ribbed discharge flange
• Reverse vane impeller standard; • High-efficiency, front vane, open-style • Vortex action minimizes abrasive
open impeller available impeller with low NPSHR wear and maintains solids integrity
• SealSentry seal chambers • Run-dry capability • Standard front vane, open-style
• Accepts multiple seal arrangements • SealSentry seal chambers impeller precision cast in CD4MCuN
• External micrometer impeller • Accepts multiple seal arrangements • SealSentry seal chambers
adjustment mechanism • External micrometer impeller • Accepts multiple seal arrangements
• Standard non-contacting labyrinth seal adjustment mechanism • External micrometer impeller
• Heavy-duty radial and thrust bearings • Standard non-contacting labyrinth seal adjustment mechanism
• Two-piece bearing housing • Heavy-duty radial and thrust bearings • Standard non-contacting labyrinth seal
• Back pullout design • Back pullout design • Heavy-duty radial and thrust bearings
• IPS Beacon electronic vibration and • IPS Beacon electronic vibration and • Two-piece bearing housing
temperature condition monitor temperature condition monitor • Back pullout design
• Optional ISO 3A power end with • Optional ISO 3A power end with • IPS Beacon electronic vibration and
lifetime warranty lifetime warranty temperature condition monitor
• CE marked; ATEX compliant; • CE marked; ATEX compliant; • Optional ISO 3A power end with
GOST certificate available GOST certificate available lifetime warranty
• CE marked; ATEX compliant;
Related Configurations Other Configurations GOST certificate available
• Mark 3 ISO Self-Priming • Mark 3 ISO Close Coupled,
• Mark 3 ISO Recessed Impeller Self-Priming Other Configurations
• Mark 3 ISO Close Coupled • Mark 3 ISO Magnetic Drive, • CPXV Recessed Impeller, Sump
• CPXV Chemical Sump Self-Priming • Mark 3 ISO Close Coupled,
• Mark 3 ISO centerline mounted Recessed Impeller
See Bulletin PS-10-31.
12 See Bulletin PS-10-31. See Bulletin PS-10-31.
Mark 3 ISO Close Coupled CPXV Chemical Sump CPXS Magnetic Drive

Overhung — Chemical Process


Standards Standards Standards
• ISO 2858 • ISO 13709/API 610, 8th & 10th ed. • ISO 2858
• ISO 5199 • ISO 5199 • ISO 15783

Operating Parameters Operating Parameters Operating Parameters


• Flows to 750 m3/h (3300 gpm) • Flows to 1400 m3/h (6160 gpm) • Flows to 420 m3/h (1850 gpm)
• Heads to 100 m (330 ft) • Heads to 250 m (820 ft) • Heads to 160 m (525 ft)
• Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi)
• Temperatures from -80°C (-110°F) • Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 160°C (320°F) to 400°C (752°F) to 250°C (480°F)

Features Features Features


• Compact, space-saving configuration • Heavy-duty casing with multi-ribbed • Reinforced PEEK® or Alloy C-276
• Investment cast muff coupling discharge flange primary containment shell
• Heavy-duty casing with integral foot • High-efficiency, front vane, open-style • Optional Alloy C-276 secondary
and multi-ribbed discharge flange impeller containment shell
• Radiating surfaces • Column lengths to 10 m (32 ft) • High-performance rare earth magnets
• Reverse vane impeller standard; • Heavy-duty thrust bearings with axial • Large inner magnet clearances
front vane, open-style impeller adjustment above soleplate level • Optimized internal flow circulation path
available • Accepts multiple seal arrangements • Heavy-duty casing with integral foot
• SealSentry seal chambers • Elastomeric split element coupling and multi-ribbed discharge flange
• Accepts multiple seal arrangements • Options • High-efficiency, front vane, open-style
• External micrometer impeller −−Recessed impeller impeller with low NPSHR
adjustment mechanism −−Suction strainer • Advanced sintered silicon carbide
• Accepts standard electric motors −−Spacer coupling bushings and journal bearings
• Standard non-contacting −−Rectangular or circular soleplate • Standard and contained back
labyrinth seal −−Oil lubrication to thrust bearing pullout design
• Back pullout design −−Zone Ø hazardous area beneath • CE marked; ATEX compliant;
• CE marked; ATEX compliant; soleplate configuration GOST certificate available
GOST certificate available • CE marked; ATEX compliant;
GOST certificate available Other Configurations
Other Configurations • Mark 3 ISO Close Coupled,
• Mark 3 ISO Close Coupled, Other Configurations Magnetic Drive
Recessed Impeller • CPXV Recessed Impeller, Sump • Mark 3 ISO Magnetic Drive,
• Mark 3 ISO Close Coupled, • Fully jacketed, molten salt design Self-Priming
Self-Priming
See Bulletin PS-10-31. See Bulletin PS-10-31.
See Bulletin PS-10-31.
® PEEK is a registered trademark of Victrex plc Corp. 13
PolyChem GRP PolyChem VGRP PolyChem S-Series
Engineered Polymer Engineered Polymer Fluoropolymer Lined
Composite Composite Sump
Overhung — Chemical Process

Standards Standards Standards


• ASME (ANSI) B73.5 • Flowserve • ASME (ANSI) B73.1
• ISO 2858
Operating Parameters Operating Parameters • JIS drilling
• Flows to 2050 m3/h (9000 gpm) • Flows to 565 m3/h (2500 gpm)
• Heads to 150 m (500 ft) • Heads to 110 m (350 ft) Operating Parameters
• Pressures to 17 bar (250 psi) • Pressures to 17 bar (250 psi) • Flows to 420 m3/h (1850 gpm)
• Temperatures from -45°C (-50°F) • Temperatures from -30°C (-20°F) • Heads to 145 m (480 ft)
to 120°C (250°F) to 90°C (200°F) • Pressures to 17 bar (250 psi)
• Temperatures from -30°C (-20°F)
Features Features to 150°C (300°F)
• Glass-reinforced vinyl ester • Glass-reinforced vinyl ester
• Unitized casing with integrally • Unitized casing with integrally Features
molded, fully gusseted suction and molded, fully gusseted suction and • PFA-lined wet end
discharge flanges discharge flanges • Metal armor meets material
• Tapered polygon impeller drive • Externally adjustable, semi-open specifications of ASTM A395
• Seal chamber accommodates multiple impeller and GGG 40.3
seals, glands and flush arrangements • Shaft and bearing system operates • Enclosed impeller standard; open
• Standard Mark 3A power end well below the first critical speed impeller optional
– External micrometer impeller • Self-lubricated or external flush • Standard Mark 3A power end
adjustment mechanism bearings • SealSentry seal chamber
­­­– Heavy-duty radial and thrust bearings • Single-piece, lightweight, filament- accommodates multiple seal types
– Double lip oil seals wound, reinforced fiberglass • Choice of solid or sleeved shaft
– Constant level oiler composite column • Bearing housing options
• Optional ANSI 3A power end with • Single and duplex configurations – Labyrinth oil seals
lifetime warranty • Full basket strainer – Oil slinger
– Certified clean room assembly • NEMA TCV motor – Regreasable or double-shielded
– Inpro/Seal VBXX isolators • Fiberglass mounting plate bearings
– Magnetic drain plug • Tapered polygon impeller drive – Oil mist lubrication
• IPS Beacon electronic vibration and • Pullout bearing retainers • Optional ANSI 3A power end with
temperature condition monitor • Level controls lifetime warranty
• Choice of shaft metallurgy – Certified clean room assembly
Related Configurations – Inpro/Seal VBXX isolators
• PolyChem VGRP engineered polymer Related Configurations – Magnetic drain plug
composite sump • PolyChem GRP engineered polymer • IPS Beacon electronic vibration and
• Self-primer composite temperature condition monitor

See Bulletin PS-10-17. See Bulletin PS-10-17. See Bulletin PS-10-17.


14
PolyChem M-Series Polyshield Baseplate Polybase
Fluoropolymer Lined, and Foundation System Polymer Concrete
Magnetic Drive Baseplate

Overhung — Chemical Process


Standards Standards Standards
• ASME (ANSI) B73.1 • Flowserve • ANSI and ISO standard designs
• ISO 2858
• JIS drilling Operating Parameters Features
• Temperatures to 260°C (500°F) • Solid polymer concrete construction
Operating Parameters • Low installed cost
• Flows to 135 m3/h (600 gpm) Features • Superior flatness
• Heads to 145 m (480 ft) • Combines non-metallic baseplate • Enhanced vibration dampening
• Pressures to 17 bar (250 psi) and formed concrete foundation for • Excellent corrosion resistance
• Temperatures from -30°C (-20°F) pump driver in one complete unit • Outstanding resistance to twisting
to 150°C (300°F) • Excellent corrosion resistance or diaphragming
• Improved vibration dampening • 8-point™ adjuster alignment system
Features • Reduced installation costs and time • Choice of three polymer materials
• PFA-lined wet end • Solid one-piece polymer motor • Options
• Ductile cast iron casing with mounting block with four 304 SS – Polybloc™ motor mounting blocks
3 mm (0.1 in) minimum PFA liner transverse motor block adjusters – Catch basin
• PFA-lined fiberglass containment shell • Self-venting design with grout hole – Grout hole
• Enclosed PFA-lined impeller and plug – Alternate equipment inserts
• Rare earth magnets in • Standard 316 stainless steel inserts
synchronous drive • Integral catch basin with NPT See Bulletin PS-10-13.
• Metal armor meets material connection
specifications of ASTM A395 • Uses 200 bar (3000 psi) concrete
and GGG40.3 • Suitable with ANSI, ISO, API and
• Separate inner magnet and impeller other foot-mounted and centerline
components mounted pumps
• Rotating shaft design • Outstanding flatness
• Silicon carbide radial and axial • Options
thrust bearings – Choice of three polymer materials
• Choice of bearing lubrication – Alloy 20 and Alloy C-276
• Options inserts available
– Long and close coupled designs – CPVC drain connection
– ANSI 3A power end
See Bulletin PS-90-2.
See Bulletin PS-10-17.

15
HPX (OH2) HPXM (OH2) PHL (OH2)
Centerline Mounted Centerline Mounted, Centerline Mounted
Low-Flow
Overhung — API Process

Standards Standards Standards


• ISO 13709/API 610 (OH2), latest ed. • ISO 13709/API 610 (OH2), latest ed. • ISO 13709/API 610 (OH2), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2000 m3/h (8800 gpm) • Flows to 30 m3/h (130 gpm) • Flows to 900 m3/h (4000 gpm)
• Heads to 350 m (1100 ft) • Heads to 280 m (920 ft) • Heads to 400 m (1300 ft)
• Pressures to 80 bar (1160 psi) • Pressures to 80 bar (1160 psi) • Pressures to 40 bar (600 psi)
• Temperatures from -160°C (-250°F) • Temperatures from -160°C (-250°F) • Temperatures from -160°C (-250°F)
to 450°C (842°F) to 450°C (842°F) to 450°C (842°F)
• Motor sizes to 110 kW (150 hp)
Features Features
• Centerline-supported casing • Low-flow, high-head design Features
• Nozzle loading capability beyond • Replaceable volute inserts • Centerline-supported, end
ISO 13709/API 610 requirements • High-efficiency radial blade impeller suction casing
• Dynamically balanced impeller • Full interchangeability with HPX bear- • Custom-tuned hydraulics
• Rugged shaft design ing assembly and mechanical seals • Multi-channel diffuser technology
• ISO 21049/API 682 seal chamber • Choice of bearings −−Customized BEP fits
accommodates multiple seal types – Standard single row, deep groove, −−High efficiency
• Choice of bearings radial bearing and duplex, single row −−Extended MTBR
– Standard single row, deep groove, 40° angular contact thrust bearings −−Low vibration
radial bearing and duplex, single row – Special bearing arrangements for −−Low noise
40° angular contact thrust bearings high suction pressures • Low shaft deflection at any flow
– Special bearing arrangements for • ISO 21049/API 682 seal chamber • ISO 21049/API 682 seal chamber
high suction pressures accommodates multiple seal types accommodates multiple seal types
• Bearing lubrication and cooling options • Bearing lubrication and cooling including dual pressurized,
– Oil mist and oil purge options unpressurized and gas
– Fan cooling – Oil mist and oil purge • Bearing housing cooling options
– Finned cooling insert – Fan cooling – Air fan
– Finned cooling insert – Water jacket
Related Configurations • Optional inducer • Replaceable diffusers
• HPXT centerline mounted, top suction • Available boron diffusion
• HPXH centerline mounted, high Related Configurations surface treatment
suction pressure • HPX centerline mounted
• HPXSL centerline mounted, slurry Other Configurations
• HPXIND centerline mounted, inducer See Bulletin PSS-10-5.1. • Top suction nozzle
• HPXCC centerline mounted,
coke crusher See Bulletin PSS-10-5.2.
16 See Bulletin PS-10-5.
ERPN PVXM (OH3) HWMA (OH3)
Centerline Mounted Vertical In-Line Vertical In-Line, Low-Flow,
High-Head

Overhung — API Process


Standards Standards Standards
• Flowserve • ISO 13709/API 610 (OH3), latest ed. • ISO 13709/API 610 (OH3), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1100 m3/h (4800 gpm) • Flows to 500 m3/h (2200 gpm) • Flows to 45 m3/h (200 gpm)
• Heads to 230 m (750 ft) • Heads to 275 m (900 ft) • Heads to 440 m (1455 ft)
• Pressures to 60 bar (870 psi) • Pressures to 40 bar (600 psi) • Pressures to 60 bar (870 psi)
• Temperatures to 350°C (660°F) • Temperatures from -100°C (-148°F) • Temperatures from -50°C (-58°F) to
to 250°C (480°F) 260°C (500°F)
Features
• Critical parameters meet Features Features
ISO 13709/API 610 (OH2) • Space-saving design • Space-saving design
– Vibration limits • Precision-machined diffusers • Low-flow, high-head hydraulics
– Deflection limits at seal faces • Customizable hydraulics — 150 BEP • Replaceable volute inserts
– Nozzle loading capabilities hydraulic fits with 10 casings • Customizable hydraulics — 80 BEP
– Balancing grades • Casing and cover design with fits in a single pump size
• ISO 21049/API 682 seal chamber metal-to-metal fits and fully confined • Casing and cover design with metal-
accommodates multiple seal types compression gasket to-metal fits and fully confined
• Dynamically balanced, high- • ASME (ANSI) B16.5 Class 300 compression gasket
efficiency impeller raised face flanges • ASME (ANSI) B16.5 Class 600 raised
• Centerline-supported casing • Dynamically balanced impeller face flanges; flat face optional
• Double volute design for discharge • Optimized NPSHR due to suction • Radial blade impeller
flanges 80 mm (3 in) and larger box design • Optional inducer for low NPSHR
• Renewable casing and cover • ISO 21049/API 682 seal chamber • ISO 21049/API 682 seal chamber
wear rings • Heavy-duty motor support head fits • Heavy-duty motor support head fits
• Back pullout design NEMA, C-Face and IEC drivers NEMA, C-Face, P-base and IEC drivers
• Optional inducer • 100% back pullout design • 100% back pullout design
• Choice of API materials • Flexible disc spacer coupling • Flexible disc spacer coupling
• Upper and lower labyrinth bearing • Upper labyrinth bearing isolator;
Related Configurations isolators; optional radial lip seals optional radial lip seals
• ERPN-O semi-open impeller • Bearing lubrication options • Choice of bearing lubrication systems
• High suction pressure: −−Oil cascade
35 bar (500 psi) −−Oil mist Related Configurations
−−Grease lube • WMA rigidly coupled, vertical in-line
See Bulletin PS-10-20. • HWMA2 two-stage, vertical in-line
Related Configurations • WMA2 rigidly coupled, two-stage,
• PVML vertical in-line vertical in-line

See Bulletin PS-10-29. See Bulletin PS-10-25. 17


PVML (OH5) MSP DSVP (OH4)
Vertical In-Line Vertical In-Line, Vertical In-Line
Medium Speed
Overhung — API Process

Standards Standards Standards


• ISO 13709/API 610 (OH5), latest ed. • Flowserve • ISO 13709/API 610 (OH4), latest ed.
• BS 4082R
Operating Parameters Operating Parameters
Operating Parameters • Flows to 27 m3/h (120 gpm) • Flows to 3400 m3/h (15 000 gpm)
• Flows to 500 m3/h (2200 gpm) • Heads to 900 m (2955 ft) • Heads to 150 m (492 ft)
• Heads to 275 m (900 ft) • Pressures to 60 bar (870 psi) • Pressures to 40 bar (600 psi)
• Pressures to 40 bar (580 psi) • Maximum suction pressure to • Temperatures to 340°C (650°F)
• Temperatures from -100°C (-148°F) 40 bar (580 psi) • Motor ratings to 895 kW (1200 hp)
to 250°C (480°F) • Temperatures from -40°C (-40°F)
to 350°C (660°F) Features
Features • Speeds from 2000 rpm to 8000 rpm • Space-saving design
• Space-saving, alignment-free design • ISO 21049/API 682 seal chamber
• Custom-tuned hydraulics Features accommodates multiple seal types
• State-of-the-art diffuser technology • Closely follows ISO 13709/API 610 • Double-suction enclosed impeller
−−Customized BEP fits (OH4), latest edition • Double volute case design
−−High efficiency • Modified concentric volute • Standard case wear rings
−−Extended MTBR • Open impeller with balance holes • Optional impeller wear rings
−−Low vibration and scallops • Metal-to-metal case to cover
−−Low noise • Variable frequency drive sealing with confined gasket
• ISO 21049/API 682 seal chamber • Rigid coupling • Rigid spacer coupling
accommodates multiple seal types • Single- or dual-cartridge • Impeller nut design, threaded
• Dynamically balanced impeller mechanical seals to tighten with rotation
• Positively locked, anti-rotation • Options
impeller nut with threads unexposed – Inducer
to pumped fluid – Choice of materials

Related Configurations Available Configurations


• PVXM vertical in-line • Horizontal configuration
• MSP vertical in-line, single-stage
See Bulletin PS-10-28. • MSP2 vertical in-line, two-stage
(opposed impellers)

See Bulletin PS-10-1.

18
M R Titan Slurry
Hard Metal, Radially Split, Heavy-Duty, Radially Split,
Abrasive Slurry Rubber-Lined Slurry Lined Slurry

Overhung — Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 10 000 m3/h (44 000 gpm) • Flows to 10 000 m3/h (44 000 gpm) • Flows to 3600 m3/h (16 000 gpm)
• Heads to 90 m (300 ft) • Heads to 50 m (165 ft) • Heads to 90 m (300 ft)
• Pressures to 10 bar (150 psi); • Pressures to 10 bar (150 psi) • Pressures to 40 bar (580 psi)
50 bar (725 psi) with the high- standard; 24 bar (350 psi) optional • Temperatures to 110°C (225°F)
pressure model • Temperatures to 110°C (225°F) • Sizes from 50 mm (2 in) to
• Temperatures to 120°C (250°F) • Solids from 2% to 70% by weight 350 mm (14 in)
• Solids from 2% to 70% by weight
Features Features
Features • Concentric, cast iron casing with • Fully interchangeable elastomeric
• One-piece high chrome iron, replaceable, abrasion-resistant or hard metal liners
concentric casing with replaceable rubber liner • Radially split casing
gland and suction side wear plates • Rubber-lined, closed impeller with • High-efficiency, closed impeller
• Closed impeller with pump-out vanes front and rear pump-out vanes • Ample seal chamber accommodates
on front and rear shrouds • Standard packing stuffing box with a variety of packing and seal types
• Standard packing stuffing box with replaceable wear plate • Heavy-duty bearing frame sized
replaceable wear plate • Full and low-flow flush connections to handle belt loads
• Full and low-flow flush connections • Heavy-duty bearing frame • Bearing cartridge with back-to-back
• Heavy-duty bearing frame • Three-point external end clearance angular contact thrust bearings
designed for V-belt loads adjustment • Roller-type radial bearings
• Cartridge style bearings • Parts interchangeable with M pump • Contact lip seals
• Parts interchangeable with R pump • Directly coupled or V-belt driven • Dimensionally compatible with the
• Three-point external end • Options industry’s most widely used pumps
clearance adjustment – Acid-resistant stuffing box kits • Optional expeller for dynamic sealing
• Options – Hard metal expeller
– Vortex semi-recessed impeller – Mechanical seal housing Available Configurations
– Hard metal expeller – Choice of liner materials • Metal-lined model
– Mechanical seal housing • Rubber-lined model
Related Configurations • High-pressure model
Related Configurations • RJ rubber-lined, slurry sump
• Severe-duty model • RJC cantilever rubber-lined, See Bulletin PS-10-8.
• High-pressure model slurry sump
• MJ slurry sump
• MJC cantilever slurry sump See Bulletin PS-10-18.

See Bulletin PS-10-19. 19


LC MND MNR
Chemical Slurry Hard Metal Rubber-Lined
Absorber Recirculation Absorber Recirculation
Overhung — Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 8000 m3/h (35 200 gpm) • Flows to 17 500 m3/h (77 000 gpm) • Flows to 17 500 m3/h (77 000 gpm)
• Heads to 90 m (300 ft) • Heads to 40 m (130 ft) • Heads to 40 m (130 ft)
• Pressures to 25 bar (360 psi) • Sizes from 600 mm (24 in) to • Sizes from 600 mm (24 in) to
• Temperatures to 140°C (285°F) 1000 mm (40 in) 1000 mm (40 in)
• Specific gravities to 1.7
Features Features
Features • One-piece, high-efficiency impeller • One-piece, high-efficiency impeller
• Concentric casing with tangential with mixed flow vane design with mixed flow vane design
discharge • Multiple materials of construction • Removable one-piece elastomeric
• Rigid, one-piece bearing frame • Replaceable casing wear ring casing liner
with two angular contact outboard • Opposed tapered roller bearings • Radially split casing
bearings and roller inboard bearings designed for a minimum B10 life • Multiple materials of construction
• Large diameter, heavy-duty shaft of 100 000 hours • Replaceable casing wear ring
• Choice of shaft sealing options • Product flush slurry seal • Opposed tapered roller bearings
– Wet gland packing • External end clearance adjustment designed for a minimum B10 life
– Single or double mechanical seal • Front and back pullout of 100 000 hours
– High-pressure double • Product flush slurry seal
mechanical seal Related Configurations • External end clearance adjustment
– Special high solids seals • Vertical mounting • Front and back pullout
– Alumina industry seal • MNR rubber-lined absorber
• Choice of materials of construction recirculation Related Configurations
• Multiple impeller designs • Vertical mounting
• Direct-coupled or belt-driven See Bulletin PS-10-32. • MND hard metal absorber
• Choice of six drive arrangements recirculation
• Options
– Inducer See Bulletin PS-10-32.
– Stuffing box cooling system

Related Configurations
• PL-C cantilever, chemical
slurry sump
• LC-S lineshaft, chemical
slurry sump
20 See Bulletin PS-10-11.
FRBH FRBHJC MPT
Heavy-Duty Paper Stock Cantilever Sump Self-Priming,
and Process Solids Handling

Overhung — Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 9085 m3/h (40 000 gpm) • Flows to 2700 m3/h (12 000 gpm) • Flows to 600 m3/h (2650 gpm)
• Heads to 100 m (330 ft) • Heads to 100 m (330 ft) • Heads to 35 m (115 ft)
• Pressures to 14 bar (200 psi) • Temperatures to 150°C (300°F) • Working pressures to 5 bar (72 psi)
• Temperatures to 150°C (300°F) • Speeds to 1780 rpm • Temperatures to 75°C (165°F)
• Sizes 50 mm (2 in) to 200 mm (8 in)
Features Features • Solids to 75 mm (3 in) diameter
• Self-venting, top centerline • True stiff shaft cantilever design,
discharge casing without bottom bearing or Features
• Semi-open, full vane impeller with flushing water • Two-vane, semi-open, solids
back pump-out vanes • Steep head capacity handling impeller
• Large suction inlet • Semi-open, full vane impeller with • External impeller adjustment
• Seal chamber accepts packing or back pump-out vanes • Abrasion-resistant, double
mechanical seal • Direct coupled or V-belt driven mechanical seal
• Three-point end clearance adjustment • Extra heavy-duty alloy steel shaft • Quick-disconnect cover plate
• Back pullout design • Heavy-duty volute casing
• Heavy-duty, oil-lubricated bearings Related Configurations • Replaceable seal housing
• Fully split interlocking glands • FRBH heavy-duty paper stock • Replaceable and reversible
• Extra heavy-duty alloy steel shaft and process wear plate
• Contoured wearplate match • FRBHJ vertical lineshaft sump • Solid one-piece flap valve
machined with impeller • Back pullout design
• Dry shaft construction with sealed See Bulletin PS-10-16. • Multiple drive options
impeller nut and stainless steel • Extra large diameter shaft
hook sleeve
• Rigid, one-piece bearing frame See Bulletin PS-10-9.
• Options
– Large conical seal housing
– Inducer
– Expeller
– Recessed impeller

Related Configurations
• FRBHJC cantilever sump
• FRBHJ sump

See Bulletin PS-10-16. 21


MF MN MSX
Solids Handling Large Capacity, Solids Handling,
Solids Handling Submersible
Overhung — Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2275 m3/h (10 000 gpm) • Flows to 45 500 m3/h (200 000 gpm) • Flows to 4545 m3/h (20 000 gpm)
• Heads to 90 m (300 ft) • Heads to 90 m (300 ft) • Heads to 90 m (300 ft)
• Sizes to 400 mm (16 in) • Sizes to 1800 mm (72 in) • Temperatures to 40°C (104°F)
• Discharge sizes from 80 mm (3 in)
Features Features to 500 mm (20 in)
• Variety of nozzle position options • Variety of nozzle position options • Motor ratings to 224 kW (300 hp)
• Direct or independent motor mounting • Direct or independent motor mounting • Solids handling to 80 mm (3 in)
• Minimal shaft deflection • Minimal shaft deflection diameter spherical
• Oversized shaft and reduced overhang • Oversized shaft and reduced overhang
• Hardened chrome steel wear rings • Hardened chrome steel wear rings Features
• Seal chamber accommodates packing • Seal chamber accommodates packing • High-efficiency hydraulics
or mechanical seals or mechanical seals • EPACT-rated motor
• Adjustable impeller clearance • Adjustable wear ring clearance • Spike-resistant windings
• Shaft sleeve options • Shaft sleeve options • Class H insulation system
– 316 stainless steel – 316 stainless steel • Dynamically balanced shaft
– Hardened chrome steel – Hardened chrome steel and rotor
• Bearing housing features • Bearing housing features • Mounting options
– Ball or tapered roller bearings – Tapered roller bearings – Wet-pit
– Integral jacking bolts for wear – Integral jacking bolts for wear – Dry-pit
ring adjustment ring adjustment – Transportable
– Accessible lubrication points – Accessible lubrication points
Available Configurations
Available Configurations Available Configurations • MSX Series 1: sizes from
• MF horizontal, end suction • MN horizontal, end suction 75 mm (3 in) to 150 mm (6 in)
• MFV vertical with motor on • MNF vertical, bottom suction, direct • MSX Series 2/3: sizes to
separate floor (shown) connected motor 500 mm (20 in)
• MFC vertical with direct connected • MNZ vertical, bottom suction, motor
motor on separate floor See Bulletin PS-50-2.
• MNC vertical with base elbow, direct
See Bulletin PS-10-3. connected motor
• MNV vertical with base elbow, motor
on separate floor (shown)

See Bulletin PS-10-4.


22
D800 Series MEN MENBLOC
Cast Iron End Suction Close Coupled

Overhung — Industrial Process


Standards Standards Standards
• Flowserve • DIN 24255 • DIN 24255
• EN 733 • EN 733
Operating Parameters • Flowserve • Flowserve
• Flows to 340 m3/h (1500 gpm)
• Heads to 120 m (395 ft) Operating Parameters Operating Parameters
• Pressures to 15 bar (220 psi) • Flows to 800 m3/h (3520 gpm) • Flows to 340 m3/h (1500 gpm)
• Temperatures to 120°C (250°F) • Heads to 140 m (450 ft) • Heads to 100 m (330 ft)
• Pressures to 16 bar (230 psi) • Pressures to 16 bar (230 psi)
Features • Temperatures to 120°C (250°F) • Temperatures to 110°C (230°F)
• High-efficiency closed impeller
• Centerline discharge Features Features
• Sealed-for-life, pre-lubricated motor • 33 sizes available • Compact, space-saving configuration
bearings with two-year minimum life • Volute casing with top discharge • End suction, top discharge,
• Renewable wear rings and shaft • Dynamically balanced, precision cast volute casing
sleeves closed impeller with extended hub • Dynamically balanced, precision cast
• Pre-set mechanical seal assembly and machined shroud high-efficiency closed impeller with
• Bell-type mechanical seal cover • Impeller balance chamber and extended hub
• Standard NEMA C-face motor holes minimize axial thrust • Impeller balance chamber and holes
• Back pullout design • Open seal chamber with integral minimize axial thrust
• Threaded and flanged connections vortex breaking ribs • Open seal chamber with integral
• Oversized stainless steel shaft vortex breaking ribs
Available Configurations • Oversized bearings • Oversized stainless steel shaft
• Type D-814 frame mounted • Standard case wear rings • Oversized bearings
• Type D-824 close coupled • Back pullout design • Standard case wear rings
• Type D-834 vertical in-line • Back pullout design
Related Configurations • Baseplate and coupling not required
See Bulletin PS-10-6. • MEN-SP vertical cantilever sump • CE marked in Europe
• MHP high-pressure
• MENBLOC close coupled Related Configurations
• ME horizontal high-capacity • MEN horizontal end suction
• MEV vertical high-capacity • MEN-SP vertical cantilever sump
• MHP high-pressure
See Bulletin PS-10-2. • ME horizontal high-capacity
• MEV vertical high-capacity

See Bulletin PS-10-2.


23
ME DS SMP
End Suction Double Volute, Standard Motor
End Suction
Overhung — Industrial Process

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 3000 m3/h (13 200 gpm) • Flows to 5700 m3/h (25 000 gpm) • Flows to 135 m3/h (600 gpm)
• Heads to 90 m (295 ft) • Heads to 110 m (350 ft) • Heads to 70 m (220 ft)
• Pressures from 4 bar (58 psi) to • Pressures to 27 bar (400 psi) • Pressures to 12 bar (175 psi)
16 bar (232 psi) • Temperatures to 120°C (250°F) • Temperatures from -40°C (-40°F)
• Temperatures to 120°C (250°F) to 120°C (250°F)
Features
Features • Double volute, end suction casing Features
• Single volute, end suction casing with centerline discharge • Glass reinforced polymer, high-
with tangential discharge • Mechanically balanced, radial flow efficiency, semi-open or closed
• Back pullout design impeller impellers standard
• Radial flow impeller shrouded, • Impeller balance holes minimize • Industry standard NEMA motors
keyed on shaft axial thrust • Stainless steel, self-aligned
• Impeller balance holes minimize • Seal chamber accommodates packing mechanical seal
axial thrust and multiple mechanical seal types • Back pullout design
• Bearings • Back pullout design • Clamp-type mounting plate
−−Radial ball bearing and roller • Angular contact thrust bearing and • Options
bearings (depending on size) parallel roller radial bearing – Cast iron, bronze or 316 stainless
−−Sealed-for-life for lower frames, • Grease lubrication standard; oil steel impellers
rationalized with MEN sizes lubrication optional – Stub shaft design
−−Grease-lubricated for higher frames • Choice of materials from cast iron
to super duplex Related Configurations
Related Configurations • SMX non-metallic, standard
• MEV vertical, end suction Related Configurations motor pump
• MEN horizontal, end suction • DSV vertical • VSMP vertical, standard
(low-capacity) • Directional discharge motor pump
• MHP horizontal, end suction (90° on the right or on the left)
(low-capacity, high-pressure) • Centerline mounted See Bulletin PS-10-26.
• DS horizontal, end suction
(high-capacity)

24
SMX F-Line MVE
Non-Metallic End Suction, Multistage End Suction
Standard Motor

Overhung — Industrial Process


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 25 m3/h (100 gpm) • Flows to 500 m3/h (2200 gpm) • Flows to 2700 m3/h (11 890 gpm)
• Heads to 20 m (60 ft) • Heads to 250 m (820 ft) • Heads to 15 m (50 ft)
• Pressures to 12 bar (175 psi) • Discharge pressures to 25 bar • Pressures to 7 bar (100 psi)
• Temperatures to 80°C (180°F) (365 psi) • Temperatures to 100°C (212°F)
• Temperatures to 105°C (220°F)
Features Features
• Polyphenylene sulfide (PPS) casing, Features • Single volute casing with end
adapter and impeller • Modular design suction and side discharge;
• Standard NEMA 56J frame – 8 sizes top discharge optional
C-faced motor – 15 hydraulics • Mechanically balanced, mixed
• Stainless steel, self-aligned – 2 impeller types flow impeller
mechanical seal • To 9 stages, depending on model • Seal chamber accommodates packing
• Back pullout design and operating speed and multiple mechanical seal types
• 40 mm (1.5 in) port size for hose • Sleeved shaft under sealing system • Back pullout design
connection • Cast iron EN-GJL 250 pressure • Standard angular contact radial and
casings thrust bearings
Related Configurations • Cast iron EN-GJL 250 or NORYL® • Standard grease lubrication; oil
• SMP standard motor pump impellers, depending upon model lubrication optional
• VSMP vertical standard motor pump • Steel grade C 35 E shaft • Choice of materials
• 13% chromium steel sleeve −−Cast iron
See Bulletin PS-10-26. −−Ni-Resist®
Available Configurations −−Bronze
• FP horizontal, overhung impeller −−Super duplex stainless steel
• FM horizontal, close coupled
® Ni-Resist is a registered trademark of the International
• FD vertical Nickel Co., Inc.
• FS vertical, suspended shaft wet-pit
• FMD vertical, close coupled
• FAD vertical, rigid coupled
® NORYL is a registered trademark of General Electric Company.

25
Between Bearings Pumps
Single Case — Axially Split —
Single-Stage
LR 28
LNN 28

Between Bearings Pumps


DVSH 28
LPN 29
Single Case — Axially Split —
Multistage
EC 30
UZDL 30
DMX 30
Single Case — Radially Split —
Single-Stage
HDX 31
HDX-TT 31
DVSR 31
Single Case — Radially Split —
Multistage
HED 32
HED-DS 32
WTB 32
WD 33
WDX 33
NM 33
WX 33
CSX 34
WXH 34
Double Case
WXB 35
WXB-B 35
WNC 35
CSB 35
CHTA 36
HDB 36
HSB 36
BP 36
WCC 37
HDO 37
HSO 37
WIK 37
WIKO 37

27
LR LNN DVSH (BB1)
Axially Split, Single-Stage Axially Split, Double- Axially Split, Double-
Suction, Single-Stage Suction, Single-Stage
OverhungBearings
Between – General
— Industry
Single Case — Axially Split — Single Stage

Standards Standards Standards


• Flowserve • Flowserve • ISO 13709/API 610 (BB1), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2000 m3/h (8800 gpm) • Flows to 30 000 m3/h (132 000 gpm) • Flows to 12 000 m3/h (52 835 gpm)
• Heads to 170 m (560 ft) • Heads to 300 m (985 ft) • Heads to 565 m (1854 ft)
• Pressures to 21 bar (300 psi) • Pressures to 40 bar (580 psi) • Pressures to 150 bar (2175 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 140°C (285°F) • Temperatures to 204°C (400°F)
to 150°C (300°F) • Speeds to 6000 rpm
Features
Features • Heavy-duty, double volute casing Features
• Split-case design with lifting lugs with side suction and side discharge • Double volute casing
• Low NPSH double-suction impeller • Flanges to ANSI, DIN and ISO • Hydraulically balanced double-
on many sizes standards suction impeller
• Flat or raised face suction and • Hydraulically balanced double- • ISO 21049/API 682 seal chambers
discharge flanges to ANSI, DIN and suction impeller accommodate multiple seal types
ISO standards • Optimum axial and radial thrust • Stiff shaft design
• Oil- or grease-lubricated radial and balance • Baseplate designs and pump
thrust bearings • Standard casing wear rings; optional packages engineered to contract
– Single row, deep groove ball bear- impeller wear rings requirements
ings or duplex thrust ball bearings • Seal chamber accommodates packing • Choice of bearings
– 100 000 hours typical L10 and multiple mechanical seal types – Ball radial and thrust
bearing life • 360° supported bearing housing – Sleeve radial and ball thrust
• Seal chamber accommodates • Choice of bearings – Sleeve radial and tilting pad thrust
multiple seal types −−Standard ball radial and ball thrust • Choice of materials
• Standard case wear rings; optional −−Optional double row, angular −−Carbon steel
serrated groove designs contact thrust bearings −−12% chrome
• Optional impeller wear rings −−Optional sleeve bearings −−Austenitic stainless steels
• Available high-performance coatings • Grease lubrication standard; oil mist −−Duplex stainless steels
and bath optional
Related Configurations • Choice of materials See Bulletin PS-20-2.
• LRV vertical, axially split,
single-stage Related Configurations
• LLR axially split, two-stage • LNNV vertical, single-stage
• LNNC single-stage, bottom suction
See Bulletin PS-20-3. • LNE, LNS, LNST and LNGT axially
split, single-stage
28 See Bulletin PS-20-1.
LPN (BB1)
Axially Split, Double-
Suction, Single-Stage

OverhungBearings
Between – General
— Industry
Single Case — Axially Split — Single Stage
Standards
• ISO 13709/API 610 (BB1), latest ed.

Operating Parameters
• Flows to 15 000 m3/h (65 000 gpm)
• Heads to 250 m (820 ft)
• Pressures to 25 bar (365 psi); 50 bar
(725 psi) with LPN-H model
• Temperatures from -80°C (-110°F)
to 204°C (400°F)

Features
• Double volute, near-centerline
supported casing
• ASME (ANSI) B16.5 Class 150 or
Class 300 raised face flanges
• Confined gasket design
• Hydraulically balanced double-
suction impeller
• ISO 21049/API 682 seal chambers
• Baseplate designs and pump
packages engineered to contract
• Heavy-duty, bracketed, 180°
supported carbon steel bearing
housing
• Standard non-contacting labyrinth seals
• Choice of bearings
−−Ball radial and ball thrust with oil
flinger system
−−Split sleeve radial and ball thrust
with ring oil system
−−Split sleeve radial and tilting pad
thrust with pressure lubrication

Other Configurations
• LPN-H high-pressure, double-suction
• LPN-V vertical in-line

See Bulletin PS-20-5. 29


EC UZDL (BB1) DMX (BB3)
Axially Split, Multistage Axially Split, Two-Stage Axially Split, Multistage
OverhungBearings
Between – General
— Industry
Single Case — Axially Split — Multistage

Standards Standards Standards


• Flowserve • ISO 13709/API 610 (BB1), latest ed. • ISO 13709/API 610 (BB3), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2340 m3/h (10 300 gpm) • Flows to 2950 m3/h (13 000 gpm) • Flows to 2950 m3/h (13 000 gpm)
• Heads to 650 m (2130 ft) • Heads to 685 m (2250 ft) • Heads to 2130 m (7000 ft)
• Pressures to 88 bar (1300 psi) • Pressures to 64 bar (910 psi) • Pressures to 275 bar (4000 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 204°C (400°F) • Temperatures to 204°C (400°F)
to 150°C (300°F) • Speeds to 2000 rpm • Speeds to 6000 rpm

Features Features Features


• Horizontally split case with integral • Double volute hydraulic passages • Double volute hydraulic passages
mounting feet • ISO 21049/API 682 seal chambers • Renewable case and impeller
• In-line mounted impellers • Shaft options wear rings
• Rotating assembly balanced as a unit – Double extension for connection • ISO 21049/API 682 seal chambers
• Case wear rings standard at to auxiliary pumps or hydraulic • Axially split center bushing
impeller eye turbines • Shaft options
• Diaphragm rings standard at impeller – Special shaft end machining for – Double extension for connection
back shroud hydraulic fitted couplings to auxiliary pumps or hydraulic
• Shaft protected by interstage and • Baseplate designs and pump turbines
packing sleeves packages engineered to contract – Special shaft end machining
• Seal chambers accommodate • Dynamic balancing and TIR for hydraulic fitted couplings
packing or mechanical seals verifications on assembled rotors • Interstage take-off option
• Double-row antifriction radial and • Choice of bearings • Baseplate designs and pump
thrust bearings – Ball radial and thrust packages engineered to contract
• Grease lubrication – Sleeve radial and ball thrust • Dynamic balancing and TIR
– Sleeve radial and tilting pad thrust verifications on assembled rotors
– Tilting pad radial and tilting • Choice of bearings
pad thrust – Ball radial and thrust
• Choice of materials – Sleeve radial and ball thrust
– Carbon steel – Sleeve radial and tilting pad thrust
– 12% chrome • Choice of bearing lubrication systems
– Austenitic stainless steels • Choice of bearing cooling systems
−−Duplex stainless steels • Choice of materials
– Monel®
See Bulletin PS-30-3.
See Bulletin PS-30-2.
30 ® Monel is a registered trademark of International Nickel Co.
HDX (BB2) HDX-TT (BB2) DVSR (BB2)
Radially Split, Double- Radially Split, Power Radially Split, Volute
Suction, Single-Stage Recovery Turbine Casing, Single-Stage

OverhungBearings
Between – General
— Industry
Single Case — Radially Split — Single-Stage
Standards Standards Standards
• ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4100 m3/h (18 000 gpm) • Flows to 4100 m3/h (18 000 gpm) • Flows to 3635 m3/h (16 000 gpm)
• Heads to 450 m (1500 ft) • Heads to 760 m (2500 ft) • Heads to 250 m (820 ft)
• Pressures to 42 bar (610 psi); • Pressures to 100 bar (1450 psi) • Pressures to 260 bar (3750 psi)
100 bar (1450 psi) with HDX-H model • Temperatures to 450°C (842°F) • Temperatures to 204°C (400°F)
• Temperatures to 450°C (842°F) • Speeds to 4000 rpm
Features
Features • Double volute, centerline supported, Features
• Double volute, centerline supported, self-venting casing with diffuser • Double volute casing
self-venting casing • ASME (ANSI) B16.5 Class 300 • Hydraulically balanced double-
• ASME (ANSI) B16.5 Class 300 flanges; optional Class 600 and suction impeller
flanges; optional Class 600 and 900 flanges • Staggered vane impellers
900 flanges • Dynamically balanced, double- • Stiff shaft design
• Dynamically balanced, double- suction, radial inflow turbine runner • IS0 21049/API 682 seal chambers
suction impeller • Stiff shaft design • Baseplate designs and pump packages
• Stiff shaft design • ISO 21049/API 682 seal chambers engineered to contract
• ISO 21049/API 682 seal chambers • Standard dual single-row, back-to- • Choice of bearings
• Standard dual single-row, back-to- back mounted, angular contact −−Sleeve radial and ball thrust
back mounted, angular contact thrust bearing −−Sleeve radial and tilting pad thrust
thrust bearing • Bearing options −−Tilting pad radial and tilting
• Bearing options – Sleeve radial and ball thrust pad thrust
– Sleeve radial and ball thrust – Sleeve radial and tilting pad thrust • Choice of materials
– Sleeve radial and tilting pad thrust – Lubrication systems available −−Carbon steel
– Lubrication systems available • 360° supported bearing housing −−12% chrome
• 360° supported bearing housing • Double case covers
• Double case covers
Other Configurations
Related Configurations • High-pressure
• HDX-H high-pressure, radially split, • In-line side nozzles
double-suction • Side-side nozzles (90° rotated)
• In-line side nozzles
• Same-side nozzles (90° rotated)

See Bulletin PS-20-4.


31
HED (BB2) HED-DS (BB2) WTB (BB2)
Radially Split, Two-Stage Radially Split, Double- Radially Split, Double-
Suction, Two-Stage Suction, Three-Stage
OverhungBearings
Between – General
— Industry
Single Case — Radially Split — Multistage

Standards Standards Standards


• ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1000 m3/h (4400 gpm) • Flows to 2500 m3/h (11 000 gpm) • Flows to 1400 m3/h (6165 gpm)
• Heads to 650 m (2100 ft) • Heads to 750 m (2460 ft) • Heads to 1100 m (3610 ft)
• Pressures to 120 bar (1750 psi) • Pressures to 120 bar (1750 psi) • Pressures to 108 bar (1565 psi)
• Temperatures to 450°C (842°F) • Temperatures to 450°C (842°F) • Temperatures to 430°C (800°F)
• Speeds to 3600 rpm
Features Features
• Heavy-duty, double volute casing • Double-suction, first-stage impeller Features
with 180° staggered volutes • Heavy-duty, double volute casing • Meets intent of key ISO/API
• Top-top nozzle configuration with 180° staggered volutes requirements
• ISO 21049/API 682 seal chambers • Top-top nozzle configuration • Heavy-duty, centerline supported,
• Dynamic balancing and TIR verifica- • ISO 21049/API 682 seal chambers double volute casing with integral
tions on assembled rotating element • Dynamic balancing and TIR verifica- crossover
• Baseplate designs and pump packages tions on assembled rotating element • ASME (ANSI) B16.5 Class 300 flanges;
engineered to contract • Baseplate designs and pump Class 600 and 900 flanges optional
• Choice of bearings packages engineered to contract • Dynamically balanced, double-suction
– Ball radial and thrust • Choice of bearings first-stage impeller; single-suction on
– Sleeve radial and ball thrust – Ball radial and thrust smallest three-stage only
– Sleeve radial and tilting pad thrust – Sleeve radial and ball thrust • Balance holes on second- and third-
• Choice of materials – Sleeve radial and tilting pad thrust stage impellers
– Carbon steel • Choice of materials • IS0 21049/API 682 seal chambers
– 12% chrome – Carbon steel • 360° supported bearing housing
−−Austenitic stainless steel – 12% chrome • Choice of bearings
−−Duplex stainless steel −−Austenitic stainless steel −−Sleeve radial and ball thrust
−−Monel lining −−Duplex stainless steel −−Sleeve radial and tilting pad thrust
−−Monel lining −−Dual, single row, angular contact
Other Configurations antifriction thrust bearings installed
• HED-DS radially split, double-suction, Other Configurations back-to-back and single row, deep
two-stage • HED radially split, two-stage groove antifriction radial bearing
• In-line side nozzles • In-line side nozzles
• Same-side nozzles • Same-side nozzles Available Configurations
• High-pressure • High-pressure • WTB three-stage, double-suction
• WTB two-stage, single-suction
See Bulletin PS-30-4. See Bulletin PS-30-4. • WTB two-stage, double-suction
32 See Bulletin PS-30-14.
WD and WDX NM WX
Radially Split, Multistage, Radially Split, Radially Split,
Ring Section Multistage, Ring Section Multistage, Ring Section

OverhungBearings
Between – General
— Industry
Single Case — Radially Split — Multistage
Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 190 m3/h (800 gpm) • Flows to 3000 m3/h (13 210 gpm) • Flows to 300 m3/h (1320 gpm)
• Heads to 700 m (2300 ft) • Heads to 500 m (1640 ft) • Heads to 1200 m (3940 ft)
• Pressures to 75 bar (1090 psi) • Pressures to 60 bar (870 psi) • Pressures to 150 bar (2175 psi)
• Temperatures to 210°C (410°F) • Temperatures to 140°C (285°F) • Temperatures from -50°C (-58°F)
to 204°C (400°F)
Features Features
• Multivane diffusers • Modular design Features
• Identical radially split ring – 15 sizes • Separate cast diffusers and
section sets – 22 hydraulics channel rings
• O-ring interstage sealing • Low NPSH suction volute design • Centerline mounted, self-venting
arrangement • Machined impeller shrouds for casing
• Deep groove ball bearing design increased efficiency • Top-top nozzles
• Angular contact, double row • Impeller balance holes minimize • Interstage O-ring seals
thrust bearing axial thrust • Individual impeller balance
• 360° machine registered bearing • Shrouded diffusers with return guide • Precision-fit rotor
housing fits vanes minimize radial thrust • Optional inducer for low NPSHR
• Dynamically balanced, precision • Removable seal housings
machined enclosed impellers accommodate gland packing and
• Packing or mechanical sealing mechanical seals
• Options • Standard cast iron construction;
– Multiple flange orientations high alloy construction available
– End suction design with product
lubricated sleeve bearing Other Configurations
– Radial suction design with product • NMV vertical, multistage ring section
lubricated sleeve bearing • NMD vertical, multistage ring section
– Inducer • NM-S vertical, suspended shaft
wet-pit
• NMAD vertical, rigid shaft coupling

33
CSX WXH
Radially Split, Radially Split, Multistage,
Multistage, Ring Section High-Pressure,
Ring Section
OverhungBearings
Between – General
— Industry
Single Case — Radially Split — Multistage

Standards Standards
• Flowserve • Flowserve

Operating Parameters Operating Parameters


• Flows to 600 m3/h (2650 gpm) • Flows to 900 m3/h (4000 gpm)
• Heads to 900 m (2950 ft) • Heads to 2650 m (8700 ft)
• Pressures to 100 bar (1450 psi) • Pressures to 310 bar (4500 psi)
• Temperatures to 250°C (480°F)
Features
• Multistage, ring section, foot Features
mounted design • Cast suction and discharge heads
• Dynamically balanced, precision with integral nozzles
cast, high-efficiency impellers • Single- or double-suction, first-stage
• Renewable case wear rings impeller designs
• Precision cast diffuser and • Investment cast diffusers and return
channel rings channel hydraulic passages
• Flexible nozzle orientation • Compression interstage O-ring
• Self-compensating balancing device • Separate, high-strength, sub-base
• Symmetrical suction and • Replaceable stationary wear parts
discharge heads mounted in the diffusers
• Generously proportioned shaft • Standard flanged balance drum with
• Choice of bearings serrated running clearances; optional
−−Ball radial and thrust straight balance drum
−−Sleeve radial and ball thrust • Seal chamber accepts single, double
−−Sleeve radial and tilting pad thrust and tandem mechanical seals
• Corrosion-resistant construction with • Large diameter shaft with staggered
options including duplex stainless impeller and balancing device keyways
steels, super duplex stainless steels, • No pre-warming required
and proprietary Alloy 885 • Chrome steel nozzles
• Choice of bearings
−−Ball radial and thrust
See Bulletin PS-30-15. −−Sleeve radial and ball thrust
−−Sleeve radial and tilting pad thrust

See Bulletin PS-30-1.

34
WXB and WXB-B WNC CSB
Diffuser Casing, Diffuser Casing, Diffuser Casing,
Multistage, Process Barrel Multistage, Utility Barrel Multistage, Utility Barrel

OverhungBearings
Between – General
— Industry
Double Case
Standards Standards Standards
• ASME Section VIII • ASME Section VIII • ASME Section VIII

Operating Parameters Operating Parameters Operating Parameters


• Flows to 300 m3/h (1320 gpm) • Flows to 1400 m3/h (6200 gpm) • Flows to 1500 m3/h (6600 gpm)
• Heads to 1200 m (3940 ft) • Pressures to 350 bar (5075 psi) • Discharge pressures to 300 bar
• Pressures to 150 bar (2175 psi) • Temperatures to 200°C (390°F) (4350 psi)
• Temperatures to 200°C (390°F) • Temperatures to 250°C (480°F)
Features • Speeds to 8000 rpm
Features • Diffuser case construction
• Diffuser case construction • Shear ring design Features
• Removeable cartridge inner case • High-strength forged steel barrel; • Internal casing with segmented
subassembly alloy barrels available stage elements
• Large eye first-stage impeller • Removable cartridge inner case • Diffuser guide-vane construction
• Low-flow, high-head Barske impeller subassembly • Precision cast in-line impellers of
on WXB-B • Shear ring barrel closing system high-quality chrome steel
• Proprietary balancing device • Single- or double-suction, first- • Heavy-duty barrel with forged steel
• Sleeve mounted deep groove radial stage impeller discharge cover
and back-to-back mounted angular • Standard antifriction or sleeve • Fully enclosed or shrouded precision
contact bearings radial bearings cast diffusers on high-energy
• High-capacity, antifriction thrust • High-capacity antifriction thrust applications
bearing bearing; tilting pad thrust • Tilt pad thrust and tri-land radial
• Bearing lubrication system with bearing available bearings
oil bath, constant level oiler and • Renewable casing rings • Renewable casing rings and sleeves
sight glass • Straight balance drum forged from • Flanged balance drum forged from
• Renewable casing and impeller rings hardened stainless steel hardened stainless steel; straight
• High shaft diameter to bearing • Chrome-plated shafting under drum optional
span ratio journal bearings • Chrome-plated shafting under
• Options • Ground forged steel shafting journal bearings
– Hydrodynamic sleeve radial bearings • Ground forged steel shafting
– Thrust bearing cooling system (air) Related Configurations
– Labyrinth end seals • WNC-HP high-pressure, diffuser See Bulletin PS-30-12.
casing, multistage, utility barrel
Available Configurations
• WXB: standard hydraulics See Bulletin PS-30-12.
• WXB-B: low-flow, high-head hydraulics

See Bulletins PS-30-6 and PSS-30-6.1.


35
CHTA HDB and HSB BP (BB5)
Diffuser Casing, Volute Casing, Diffuser Casing,
Multistage, Utility Barrel Multistage, Utility Barrel Multistage, Process Barrel
OverhungBearings
Between – General
— Industry
Double Case

Standards Standards Standards


• ASME Section VIII • ASME Section VIII • ISO 13709/API 610 (BB5), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 5220 m3/h (23 000 gpm) • Flows to 4000 m3/h (17 610 gpm) • Flows to 1050 m3/h (4620 gpm)
• Heads to 4270 m (14 000 ft) • Heads to 4300 m (14 000 ft) • Heads to 3500 m (11 480 ft)
• Discharge pressures to 517 bar • Discharge pressures to 450 bar • Discharge pressures to 295 bar
(7500 psi) (6525 psi) (4260 psi)
• Temperatures to 250°C (480°F) • Temperatures to 425°C (800°F) • Temperatures to 425°C (800°F)
• Speeds to 6000 rpm • Speeds to 9000 rpm • Speeds to 6000 rpm

Features Features Features


• Internal casing with segmented • Axially split inner casing • Diffuser guide-vane inner casing with
stage elements • Double volute design with segmented stage elements
• Diffuser guide-vane construction symmetrical upper and lower halves • Inner casing bolted head at one end
• Precision cast in-line impellers • Opposed impeller design • Heavy-duty barrel with forged steel
of high-quality chrome steel • Volute and impellers are cast of discharge cover
• Heavy-duty barrel with forged steel high-quality chrome steel • Multi-vane diffuser and channel
discharge cover • Heavy-duty forged steel barrel ring design
• Fully enclosed or shrouded and discharge cover • Precision cast diffusers
precision cast diffusers on high- • Individually mounted and secured • Precision cast keyed impellers;
energy applications impellers optional shrink-fit impellers for high-
• Balance drum and sleeve made from • Dynamic balancing and TIR speed or high-temperature service
hardened stainless steel forgings verifications on assembled rotor • Single- or double-suction, first-stage
• Tilt pad thrust and tri-land radial • Minimal pressure breakdowns impeller
bearings across running clearances • Straight style balance drum
• Serrated running fits • Sleeve radial and tilting pad • Forged shaft; optional stepped
• Renewable casing rings and sleeves thrust bearings shaft for high-speed or high-
• Flanged balance drum design • Baseplate designs and pump temperature service
• Chrome-plated shafting under packages engineered to contract • Choice of bearings
journal bearings requirements −−Ball radial and ball thrust with oil
• Ground forged steel shafting flinger lubrication system
See Bulletin PS-30-12. −−Sleeve radial and tilting pad
See Bulletin PS-30-13. thrust bearings with pressure
lubrication system

See Bulletin PS-30-11.


36
WCC (BB5) HDO and HSO (BB5) WIK and WIKO (BB5)
Diffuser Casing, Volute Casing, Multistage, Diffuser Casing,
Multistage, Process Barrel Process Barrel Multistage, Process Barrel

OverhungBearings
Between – General
— Industry
Double Case
Standards Standards Standards
• ISO 13709/API 610 (BB5), latest ed. • ISO 13709/API 610 (BB5), latest ed. • ISO 13709/API 610 (BB5), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1000 m3/h (4400 gpm) • Flows to 4000 m3/h (17 610 gpm) • Flows to 4000 m3/h (17 610 gpm)
• Heads to 2800 m (9200 ft) • Heads to 5365 m (16 000 ft) • Heads to 7000 m (23 000 ft)
• Discharge pressures to 275 bar • Discharge pressures to 450 bar • Discharge pressures to 650 bar
(3987 psi) (6525 psi) (9425 psi)
• Temperatures to 425°C (800°F) • Temperatures to 425°C (800°F) • Temperatures to 450°C (842°F)
• Speeds to 3580 rpm; 6000 rpm • Speeds to 9000 rpm • Speeds to 13 000 rpm
with high-speed option
Features Features
Features • Axially split inner casing • Radially split inner casings
• Internal casing with segmented • Double volute design with • Multi-vane diffuser and channel
stage elements symmetrical upper and lower halves ring design
• Diffuser guide-vane construction • Opposed impeller design • Tandem or imposed impellers
• Multi-vane, diffuser-channel • Heavy-duty forged steel barrel • Inner casing with a bolted head at
ring collectors and discharge cover one end
• Precision cast chrome steel in-line • Individually mounted and secured – Optional cartridge element design
impellers impellers – Optional shear ring design
• Single- or double-suction, first-stage • Dynamic balancing and TIR • Heavy-duty forged steel barrel casing
impeller verifications on assembled rotor and discharge head
• Heavy-duty barrel with discharge cover • Sleeve radial and tilting pad • Precision cast and milled diffusers
• Removable cartridge inner case thrust bearings • Precision cast impellers
subassembly • Baseplate designs and pump • Shrink-fit and double-keyed impellers
• Straight or flanged balance drum packages engineered to contract • Straight balance drum
with serrated running surfaces requirements • Tilt pad thrust and sleeve radial
• Tilt pad thrust and heavy-duty • Metallurgies per ISO 13709/API 610 bearings
journal bearings • Large diameter shaft stepped at each
• Force feed lubricated bearings Other Configurations impeller and balance drum
• Precision-ground forged • Coke crusher (for most sizes) • NEMA taper shaft extension
steel shafting
See Bulletin PS-30-8. Available Configurations
See Bulletin PS-30-7. • WIK: tandem impellers
• WIKO: opposed impellers
• Coke crusher (for most sizes)

See Bulletin PS-30-9.


37
Vertical Pumps
Wet-Pit
WUJ 40
VTP 40
QL 40
QLQ 40

Vertical Pumps
VCT 41
AFV 41
CVP 41
Double Case
QLC 42
QLQC 42
VPC 42
WUC 42
APKD 43
Submersible
Pleuger SUBM 44
Byron Jackson SUBM 44
MSX 44
Slurry and Solids Handling
MVX 45
MFV 45
MNV 45
FRBHJC 46
MJ 46
MJC 46
RJ 46
RJC 46
Terra-Titan™ 47
MSX 47
Drain-Titan™ 47
Sump
CPXV Chemical Sump 48
ESP3 Chemical Sump 48
PolyChem VGRP 48
Drain-Titan 49
VSMP 49
ECPJ 49

39
WUJ (VS1) VTP QL and QLQ
Vertical Lineshaft, Vertical Turbine Vertical, Double-Suction,
Multistage Double Volute
Vertical — Wet-Pit

Standards Standards Standards


• ISO 13709/API 610 (VS1), latest ed. • Flowserve • Flowserve
• ASME Sections VIII and IX • ASME Sections VIII and IX
• Directive 94/9/EC (ATEX 100) Operating Parameters
• Flows to 13 600 m3/h (60 000 gpm) Operating Parameters
Operating Parameters • Heads to 700 m (2300 ft) • Flows to 25 000 m3/h (110 000 gpm)
• Flows to 3000 m3/h (13 200 gpm) • Pressures to 100 bar (1450 psi) • Heads to 500 m (1640 ft)
• Heads to 2000 m (6560 ft) • Temperatures from -45°C (-50°F) • Pressures to 70 bar (1015 psi)
• Pressures to 200 bar (2900 psi) to 300°C (570°F) • Temperatures to 204°C (400°F)
• Temperatures from -200°C (-328°F) • Sizes from 150 mm (6 in) to • Column sizes to 1500 mm (60 in)
to 350°C (660°F) 1375 mm (54 in)
• Settings to 365 m (1200 ft) Features
Features • Heavy-wall double volute casing
• Radial or mixed flow hydraulics Features • Double-suction, first-stage impeller
• Multivane diffuser design • Above- or below-grade discharge • Open lineshaft standard; enclosed
• Optional axial thrust tilting pad • Enclosed or semi-open impellers lineshaft optional
bearing configuration • Open or enclosed lineshaft • Heavy-duty discharge head
• Stiff shaft design construction • Sealed-for-life bottom bearing
• ISO 21049/API 682 seal chamber • Product or enclosed oil lubrication • Options
accommodates multiple seal types • Flanged or threaded column pipe – ISO 13709/API 610 (VS2), latest ed.,
• Flanged spacer coupling • High-pressure stuffing box and Directive 94/9/EC (ATEX 100)
• Screen-type, non-sparking • Rigid, adjustable coupling compliant configurations
coupling guard • Drive options – Vertical solid shaft or hollow
• Casing and impeller wear rings – Hollow or solid shaft motor shaft motors with thrust bearing
• Centerline aligned and flanged – Dry or submersible electric motors – Oiler and solenoid switch for
columns – Variable speed drives pump bearing lubrication
• Reinforced motor stand – Engine with right angle gear – Water, grease or oil lubricant
• Optional inducer – Steam turbine – Lubrication lines for bottom bearing
• Options – Antifriction (self-lubricated) or tilting
Related Configurations – Thrust-balanced impeller pad axial thrust bearing assembly
• WUC (VS6) double case, – O-ring bowl – Rigid, adjustable spacer coupling
multistage – Adjustable flanged coupling
Available Configurations
See Bulletin PS-40-8. Related Configurations • QL single-stage
• VTP molten salt design • QLQ multistage
• VPC vertical turbine, double case • QLC double case, single-stage
• QLQC double case, multistage
See Bulletin PS-40-7.
40 See Bulletin PS-40-4.
VCT AFV CVP
Vertical, Mixed Flow Vertical, Axial Flow Vertical, Concrete Volute

Vertical — Wet-Pit
Standards Standards Standards
• Hydraulic Institute • Flowserve • Flowserve
• AWWA • Hydraulic Institute
Operating Parameters
Operating Parameters • Flows to 181 700 m3/h Operating Parameters
• Flows to 181 700 m3/h (800 000 gpm) • Flows to 200 000 m3/h (800 000 gpm)
(800 000 gpm) • Heads to 11 m (35 ft) • Heads to 60 m (197 ft)
• Heads to 110 m (350 ft) • Speeds to 1770 rpm
• Sizes from 1200 mm (48 in) to • Sizes from 200 mm (8 in) to Features
3380 mm (133 in) 3.1 m (123 in) • Vertical dry-pit design
• Settings to 8 m (25 ft) • Removable metallic pump pullout
Features unit within a concrete volute
• Five-mitered elbow discharge head Features • Suction bell connected to preformed
with above- or below-grade discharge • Three- or four-vane axial flow design high-efficiency, vortex-free concrete
• Pullout or non-pullout construction • Cast or fabricated bowl assembly suction box
• Flanged outer column with integral • Flanged outer column pipe with • Open mixed flow and closed mixed
bearing bracket integral bearing bracket flow impeller options
• Enclosed or semi-open impellers • Oil, freshwater or self-lubricating • Dry shaft design
• Oil, freshwater or self-lubricating lineshaft construction • No submerged bearings
column construction • Fabricated discharge with mitered • Bearings and sealing systems
• Seal chamber accepts packing or elbow easily accessible
mechanical seal • Above- or below-ground discharge • Prefabricated concrete segments
• Three-piece rigid, adjustable • Multiple drive options • Highly corrosion and erosion resistant
motor coupling −−Solid or hollow shaft motor • Liquidyne® or mechanical shaft seal
• Shaft sleeves under the bearings and −−Steam turbine • Inflatable static seal
seal chamber −−Diesel engine • Engineered to customer specifications
• Options • Options
– Discharge head with integral axial −−Casing liners Available Configurations
thrust bearing assembly −−Integral axial thrust bearing • BSV open mixed flow impeller design
– Cast or fabricated bowl assembly assembly • BCV closed mixed flow impeller design
– Integrated suction bell bearing
bracket See Bulletin PS-40-3. See Bulletin PS-40-1.
– Multiple stages ® Liquidyne is a registered trademark of IHC.
– Thrust collar
– Sand cap
• Engineered to customer specifications

See Bulletin PS-40-6.


41
QLC and QLQC VPC WUC (VS6)
Vertical, Double Case, Vertical Turbine, Vertical, Double Case,
Double-Suction, Double Case Multistage
Double Volute
Vertical — Double Case

Standards Standards Standards


• Flowserve • ASME Sections VIII and IX • ISO 13709/API 610 (VS6), latest ed.
• ASME Sections VIII and IX • Hydraulic Institute • ASME Sections VIII and IX
• AWWA • German Pressure Vessel
Operating Parameters Association (AD)
• Flows to 25 000 m3/h (110 000 gpm) Operating Parameters • British Standard BS 5500
• Heads to 500 m (1640 ft) • Flows to 13 600 m3/h (60 000 gpm) • Compliance with Pressure
• Pressures to 70 bar (1015 psi) • Heads to 1070 m (3500 ft) Equipment Directive 97/23/EC
• Temperatures from -45°C (-50°F) • Pressures to 100 bar (1450 psi)
to 204°C (400°F) • Temperatures from -45°C (-50°F) Operating Parameters
to 230°C (450°F) • Flows to 3000 m3/h (13 200 gpm)
Features • Heads to 2000 m (6560 ft)
• Double case construction Features • Pressures to 200 bar (2900 psi)
• Heavy-wall double volute casing • Diffuser design • Temperatures from -200°C (-328°F)
• Double-suction, first-stage impeller • Above- or below-grade discharge to 350°C (660°F)
• Open lineshaft construction • ASME Class 150 or 300 slip-on flanges
• Seal chamber accommodates • Single or multistage designs Features
cartridge-style single, dual • Enclosed or semi-open impellers • Radial or mixed flow hydraulics
unpressurized and dual pressurized • Large eye first-stage impeller • Low suction velocity can design
mechanical seals • Product or oil bearing lubrication • Optional axial thrust tilting pad
• Heavy-duty discharge head • Flanged column pipe bearing configuration
• Options • High-pressure stuffing box • Stiff shaft design
−−ISO 13709/API 610 (VS7), latest • Rigid, adjustable flanged coupling • ISO 21049/API 682 seal chamber
ed., compliant designs • Drive options accommodates multiple seal types
−−Directive 94/9/EC (ATEX 100) – Hollow or solid shaft motor • Flanged spacer coupling
available – Variable speed drive • Screen-type, non-sparking
−−Hollow or solid shaft motor with – Engine with right angle gear coupling guard
thrust bearing – Steam turbine • Inside drain line
−−Antifriction (self-lubricated) or tilting • Other options • Casing and impeller wear rings
pad axial thrust bearing assembly – Integral axial thrust bearing • Reinforced motor stand
– Rigid, adjustable spacer coupling assembly • Optional inducer
– O-ring construction
Available Configurations – Keyed impellers Related Configurations
• QLC double case, single-stage – Bowl and impeller wear rings • WUJ (VS1) vertical line shaft,
• QLQC double case, multistage multistage
• QL single-stage Related Configurations • WUC-LNG cryogenic (VS6) double
• QLQ multistage • VTP vertical turbine case, multistage
42 See Bulletin PS-40-4. See Bulletin PS-40-2. See Bulletin PS-40-9.
APKD
Vertical, Double Case,
Double-Suction

Vertical — Double Case


Standards
• Flowserve

Operating Parameters
• Flows to 4600 m3/h (20 200 gpm)
• Heads to 500 m (1640 ft)
• Pressures to 50 bar (725 psi)
• Temperatures from -18°C (0°F)
to 95°C (200°F)
• Speeds to 1800 rpm

Features
• Double-suction, first-stage impeller
• Double case construction
• Impellers keyed with lock collars
• Double volute casing
• Heavy-duty discharge head
• Open lineshaft construction
• Flanged column assembly with
bearing retainers
• Large shaft with keyed lineshaft
couplings
• Mechanically sealed
• Rigid, adjustable flanged coupling
• Solid shaft motor with NEMA or IEC
thrust bearing
• Optional suction can drain

Related Configurations
• APKC single-suction design

See Bulletin PS-40-10.

43
Pleuger SUBM Byron Jackson SUBM MSX
Deep-Well Submersible Deep-Well Submersible Solids Handling,
(Water-Filled Design) (Oil-Filled Design) Submersible
Vertical — Submersible

Standards Standards Standards


• Flowserve • Flowserve • Flowserve
• CSA, WIMES 3.03, EMV, KTV, CE, • NSF Standard 61 Certification
VDE and other certifications • Certification program accredited by Operating Parameters
RvA, Dutch Council for Accreditation • Flows to 4545 m3/h (20 000 gpm)
Operating Parameters • Heads to 90 m (300 ft)
• Flows to 6000 m3/h (26 415 gpm) Operating Parameters • Temperatures to 40°C (104°F)
• Heads to 800 m (2625 ft) • Flows to 6000 m3/h (26 415 gpm) • Discharge sizes from 80 mm (3 in)
• Motor sizes to 5000 kW (6700 hp) • Heads to 800 m (2625 ft) to 500 mm (20 in)
• Speeds from 200 to 3600 rpm • Motor sizes to 1650 kW (2200 hp) • Motor ratings to 224 kW (300 hp)
• Speeds from 1000 to 3600 rpm • Solids handling to 80 mm (3 in)
Features diameter spherical
• Wet-type motors with watertight Features
insulated windings • Oil-filled motors with self-contained Features
• Dynamically balanced impellers force feed, filtered, cooled oil • High-efficiency hydraulics
• Pre-filled motors with food grade circulation system • EPACT-rated motor
additives • Vacuum pressure impregnated (VPI) • Spike-resistant windings
• Heavy-duty, adjustable, self-aligning epoxy, Class F insulation system • Class H insulation system
thrust bearings • Double-acting thrust bearing system • Dynamically balanced shaft
• Friction-welded shafts • Dynamically balanced, heavy-duty, and rotor
• Non-toxic Class Y winding insulation high-efficiency impellers • Mounting options
for potable water services • Variable frequency drive and high- – Wet-pit
• Variable frequency drive and high- temperature options – Dry-pit
temperature options • Choice of materials – Transportable
• Choice of materials – Cast iron
– Cast iron – Bronze Available Configurations
– Bronze – Austenitic stainless steels • MSX Series 1: sizes from
– Austenitic stainless steels −−Duplex stainless steels 75 mm (3 in) to 150 mm (6 in)
−−Duplex stainless steels – Reinforced composite • MSX Series 2/3: sizes to
– Reinforced composite • Choice of seals 500 mm (20 in)
– Mercury seal
Related Configurations – Double mechanical seal See Bulletin PS-50-2.
• Byron Jackson SUBM deep-well – Single, pressurized mechanical seal
submersible (oil-filled design)
Related Configurations
See Bulletin PS-50-3. • Pleuger SUBM deep-well
submersible (water-filled design)
44 See Bulletin PS-50-3.
MVX MFV MNV
Solids Handling, Wet-Pit Solids Handling Large Capacity,
Solids Handling

Vertical — Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 17 000 m3/h (75 000 gpm) • Flows to 2275 m3/h (10 000 gpm) • Flows to 45 500 m3/h (200 000 gpm)
• Heads to 40 m (130 ft) • Heads to 90 m (300 ft) • Heads to 90 m (300 ft)
• Sizes 250 mm (10 in) to 1200 mm • Sizes to 400 mm (16 in) • Sizes to 1800 mm (72 in)
(48 in)
• Drivers to 950 kW (1250 hp) Features Features
• Solids up to 150 mm (6 in) • Variety of nozzle position options • Variety of nozzle position options
• Direct or independent motor mounting • Direct or independent motor mounting
Features • Minimal shaft deflection • Minimal shaft deflection
• Heavy-duty fabricated discharge • Oversized shaft and reduced overhang • Oversized shaft and reduced overhang
head designed with fabricated flange • Hardened chrome steel wear rings • Hardened chrome steel wear rings
and splitter vane • Seal chamber accommodates packing • Seal chamber accommodates packing
• Symmetrical bowl with multi- or mechanical seals or mechanical seals
volute design • Adjustable impeller clearance • Adjustable wear ring clearance
• Hydraulically balanced design • Shaft sleeve options • Shaft sleeve options
• Enclosed non-clog impeller – 316 stainless steel – 316 stainless steel
• Enclosed lineshaft – Hardened chrome steel – Hardened chrome steel
• Splitter vane in the column and • Bearing housing features • Bearing housing features
discharge head – Ball or tapered roller bearings – Tapered roller bearings
• Mechanical seal or soft packing shaft – Integral jacking bolts for wear – Integral jacking bolts for wear
sealing options ring adjustment ring adjustment
• Hollow or solid shaft motor style – Accessible lubrication points – Accessible lubrication points
• 416 stainless steel lineshafts
• Separate steel soleplate Available Configurations Available Configurations
• Bronze lineshaft bearings • MF horizontal, end suction • MN horizontal, end suction
• Suction bell • MFV vertical with motor on • MNF vertical, bottom suction,
• Standard suction bell wear rings separate floor (shown) direct connected motor
• Optional impeller wear rings • MFC vertical with direct connected • MNZ vertical, bottom suction,
motor motor on separate floor
See Bulletin PS-40-5. • MNC vertical with base elbow,
See Bulletin PS-10-3. direct connected motor
• MNV vertical with base elbow,
motor on separate floor (shown)

See Bulletin PS-10-4.


45
FRBHJC MJ and MJC RJ and RJC
Cantilever Sump Hard Metal, Slurry Sump Rubber-Lined, Slurry Sump
Vertical — Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2700 m3/h (12 000 gpm) • Flows to 1350 m3/h (6000 gpm) • Flows to 1350 m3/h (6000 gpm)
• Heads to 100 m (330 ft) • Heads to 30 m (100 ft) • Heads to 30 m (100 ft)
• Temperatures to 150°C (300°F) • Pressures to 10 bar (150 psi) • Pressures to 10 bar (150 psi)
• Speeds to 1780 rpm • Temperatures to 110°C (225°F) • Temperatures to 110°C (225°F),
• Solids from 2% to 70% by weight depending on material
Features • Speeds to 1780 rpm • Solids from 2% to 70% by weight
• True stiff shaft cantilever design, • Speeds to 1780 rpm
without bottom bearing or Features
flushing water • Abrasion- and corrosion-resistant Features
• Steep head capacity high chrome iron concentric casing • Radially split casing with anti-
• Semi-open, full vane impeller with • Integrally cast straightening vanes prerotation vanes in suction nozzle
back pump-out vanes in the suction nozzle • Casing liners pressure molded
• Direct-coupled or V-belt driven • Closed impeller with pump-out vanes on steel backing plates; multiple
• Extra heavy-duty alloy steel shaft on front and rear shrouds materials available
• MJ has fluted cutlass rubber • Rubber, pressure-molded closed
Related Configurations bearings impeller with pump-out vanes on
• FRBH heavy-duty paper stock • MJC has restriction bushing front and rear shrouds
and process • Directly coupled or V-belt driven • RJ has fluted cutlass rubber
• FRBHJ vertical lineshaft sump • Options bearings
– Hard metal expeller • RJC has restriction bushing
See Bulletin PS-10-16. – Open and recessed impellers • Directly coupled or V-belt driven
– Choice of materials • Options
– Hard metal expeller
Available Configurations – Choice of liner materials
• MJ submerged bearing and
lineshaft design Available Configurations
• MJC cantilever design • RJ submerged bearing and
• M horizontal, hard metal, lineshaft design
abrasive slurry • RJC cantilever design
• R horizontally split, rubber
See Bulletin PS-10-19. lined, slurry

See Bulletin PS-10-18.


46
Terra-Titan MSX Drain-Titan
Cantilever Sump Solids Handling, Urethane-Lined,
Submersible Double-Suction Sump

Vertical — Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 250 m3/h (1100 gpm) • Flows to 4545 m3/h (20 000 gpm) • Flows to 160 m3/h (700 gpm)
• Heads to 45 m (150 ft) • Heads to 90 m (300 ft) • Heads to 40 m (130 ft)
• Pressures to 5 bar (70 psi) • Temperatures to 40°C (104°F) • Pressures to 4 bar (55 psi)
• Temperatures to 100°C (212°F) • Discharge sizes from 80 mm (3 in) • Sizes from 40 mm (1.5 in) to
• Sizes from 40 mm (1.5 in) to to 500 mm (20 in) 100 mm (4 in)
125 mm (5 in) • Motor ratings to 224 kW (300 hp) • Solids to 15 mm (0.6 in)
• Sump depths from 700 mm • Solids handling to 80 mm (3 in)
(28 in) to 1800 mm (72 in) diameter spherical Features
• Double-suction, urethane-coated,
Features Features wet end
• One-piece suspended, oversized • High-efficiency hydraulics • Robust, integral unit construction
cantilever shaft construction • EPACT-rated motor • Large diameter, stiff cantilever
• Interchangeable urethane or hard • Spike-resistant windings drive shaft
metal wetted parts • Class H insulation system • No submerged bearings or seals
• Concentric casing design • Dynamically balanced shaft and • Double-sided impeller with
• Double-suction, hydraulically rotor pre-set clearance
balanced open impeller • Mounting options • Keyed and bored shaft coupling
• External impeller adjustment – Wet-pit • Standard single lip oil seal
• Renewable Terraprene urethane – Dry-pit • Urethane-lined, slotted outlet
shaft sleeve – Transportable pipe flange
• Greased-for-life, heavy-duty, • Grease-lubricated, single row,
self-aligning roller bearings Available Configurations deep groove ball bearings
• Upper and lower strainers • MSX Series 1: sizes from • No priming required
• Run-dry capability 75 mm (3 in) to 150 mm (6 in) • Run-dry capability
• ANSI and ISO configurations • MSX Series 2/3: sizes to
• Portable 500 mm (20 in) See Bulletin PS-10-7.
• Lifting lugs
• Rigid motor mount pivot bar See Bulletin PS-50-2.
• Available bottom suction tailpipe
• Multiple drive options

See Bulletin PS-10-7.

47
CPXV ESP3 PolyChem VGRP
Chemical Sump Chemical Sump Engineered Polymer
Composite Sump
Vertical — Sump

Standards Standards Standards


• ISO 13709/API 610, 8th & 10th ed. • Flowserve • Flowserve
• ISO 5199
Operating Parameters Operating Parameters
Operating Parameters • Flows to 1300 m3/h (5700 gpm) • Flows to 565 m3/h (2500 gpm)
• Flows to 1400 m3/h (6160 gpm) • Heads to 90 m (300 ft) • Heads to 110 m (350 ft)
• Heads to 250 m (820 ft) • Pressures to 12 bar (175 psi) • Pressures to 17 bar (250 psi)
• Pressures to 25 bar (365 psi) • Temperatures to 180°C (350°F) • Temperatures from -30°C (-20°F)
• Temperatures from -40°C (-40°F) to 90°C (200°F)
to 350°C (660°F) Features
• Optimized lineshaft bearing design Features
Features to ISO 13709/API 610 spacing • Glass-reinforced vinyl ester
• Heavy-duty casing with multi-ribbed requirements • Unitized casing with integrally
discharge flange • Double row external thrust bearings molded, fully gusseted suction
• High-efficiency, semi-open impeller • Single and duplex configurations and discharge flanges
• Column lengths to 10 m (32 ft) • Flanged discharge • Externally adjustable, semi-
• Heavy-duty thrust bearings with axial • Large basket strainer open impeller
adjustment above soleplate level • Industry standard TCV motors • Shaft and bearing system operates
• Accepts multiple seal arrangements • Lubrication options well below the first critical speed
• Elastomeric split element coupling – Product lube for clear liquids • Self-lubricated or external
• Options – Dual particle separator for flush bearings
−−Recessed impeller light solids • Single-piece, lightweight, filament-
−−Suction strainer – Grease lubrication wound, reinforced fiberglass
−−Spacer coupling • Mounting plate sealing options composite column
−−Rectangular or circular soleplate – Vapor-tight • Single and duplex configurations
−−Oil lubrication to thrust bearing – Vapor-proof • Full basket strainer
−−Zone Ø hazardous area beneath – Pressurized design • NEMA in-line motor
soleplate configuration • Options • Fiberglass mounting plate
• CE marked and compliant with – Upper stuffing box • Tapered polygon impeller drive
applicable European directives such – Sealing ring • Pullout bearing retainers
as ATEX; available with GOST – Suction tailpipes • Level controls
certification – Level controls • Choice of shaft metallurgy

Other Configurations Related Configurations Related Configurations


• CPXVR recessed impeller, • ESP3 Lo-Flo • PolyChem GRP engineered
chemical sump • ESP3 recessed impeller polymer composite
• Fully jacketed, molten salt design • ESP3 high chrome iron
See Bulletin PS-10-17.
48 See Bulletin PS-10-30. See Bulletin PS-10-24.
Drain-Titan VSMP ECPJ (VS4)
Urethane-Lined, Vertical Standard Motor Sump
Double-Suction Sump

Vertical — Sump
Standards Standards Standards
• Flowserve • Flowserve • ISO 13709/API 610 (VS4), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 160 m3/h (700 gpm) • Flows to 135 m3/h (600 gpm) • Flows to 1000 m3/h (4400 gpm)
• Heads to 40 m (130 ft) • Heads to 70 m (220 ft) • Heads to 150 m (500 ft)
• Pressures to 4 bar (55 psi) • Pressures to 12 bar (175 psi) • Pressures to 20 bar (285 psi)
• Sizes from 40 mm (1.5 in) to • Temperatures from -40°C (-40°F) • Temperatures to 350°C (660°F)
100 mm (4 in) to 120°C (250°F) • 45 sizes available
• Solids to 15 mm (0.6 in)
Features Features
Features • Glass-reinforced polymer, high- • Lineshaft configuration
• Double-suction, urethane-coated efficiency, semi-open or closed • Four impeller designs
wet end impellers standard – Closed multivane impeller with
• Robust, integral unit construction • Industry standard NEMA motors front wear rings and back vanes
• Large diameter, stiff cantilever • Stainless steel, self-aligned – Closed multivane impeller with
drive shaft mechanical seal front and rear wear rings
• No submerged bearings or seals • Back pullout design – Open multivane impeller with
• Double-sided impeller with • Clamp-type mounting plate back vanes
pre-set clearance • Options – Free flow impeller with back vanes
• Keyed and bored shaft coupling – Cast iron, bronze or 316 stainless • Multiple shaft sealing options
• Standard single lip oil seal steel impellers – V-ring
• Urethane-lined, slotted outlet – Stub shaft design – Throttle bushing
pipe flange – Lip seal with grease-filled
• Grease-lubricated, single row, Related Configurations stuffing box
deep groove ball bearings • SMP standard motor pump – Soft packing
• No priming required • SMX non-metallic standard • ISO 21049/API 682 seal chamber
• Run-dry capability motor pump accommodates multiple seal types
• Column lengths to 6 m (22 ft);
See Bulletin PS-10-7. See Bulletin PS-10-26. suction pipe available
• Choice of ISO/API materials
• NACE MR0175 materials available
• Internal or external bearing flushing
• Bearing cooling
• Suction strainer

See Bulletin PS-10-10.


49
Positive Displacement
Gear
GR Series 52
GA Series 52
Gearex 52

Positive Displacement
Screw
TSP 53
MP1 53
MP1 Systems Packaging 53
Reciprocating
YHT 54
HS 54
VTE 54
VQE 54
V 54
VSE 54

51
GR Series GA Series Gearex
Double Helical, Gear Double Helical, Gear Double Helical,
Timed Gear
OverhungDisplacement
Positive – General Industry
— Gear

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 275 m3/h (1200 gpm) • Flows to 27 m3/h (120 gpm) • Flows to 180 m3/h (800 gpm)
• Pressures to 35 bar (500 psi) • Pressures to 17 bar (250 psi) • Pressures to 20 bar (300 psi)
• Temperatures to 350°C (650°F) • Temperatures to 175°C (350°F) • Temperatures from -50°C (-60°F)
• Speeds to 1800 rpm • Speeds to 1800 rpm to 450°C (842°F)
• Viscosities to 20 000 cP • Viscosities to 5000 cP • Viscosities to 20 000 cP
Features Features Features
• Double helical, herringbone gears • Double helical, herringbone gears • Double helical, herringbone gears
• Quiet, pulse-free flow • Quiet, pulse-free flow • Quiet, pulse-free flow
• High-speed pump capability • High-speed pump capability with • External timing gears
• Between bearings design off-the-shelf motors • Between bearings design
• Hydraulically balanced design • Between bearings design • Heavy-duty, double row roller
• Stuffing box accommodates packing • Self-lubricated babbitted carbon bearings
or mechanical seals sleeve bearings standard; bronze • Direct coupled
• High-capacity, double row roller bearing bearings optional • Options
• Self-priming • Hydraulically balanced design requires – Water-cooled bearings
• Run-dry capability no thrust bearings – Steam- or water-jacketed bodies
• Low NPSHR • Convertible stuffing box accommo- – Vertical mounting configuration
• Back pullout design dates packing or mechanical seals – Mechanical seals
• Options • Threaded ports – Lantern rings
– Mechanical seal • Back pullout design – Shaft slingers
– Direct V-belt drive • Available integral safety relief valve – Split bearing brackets
– Extra deep jacketed stuffing box • Multiple mounting configurations – Flange mounting brackets
– Jacketed body – Jackshafts for V-belt drives
– Babbitted carbon sleeve bushing Related Configurations
– INSUROCK® wearplates • GAS foot mounting (standard) See Bulletin PS-60-4.
– Integral safety relief valve • GAF flange mounting
• GAC close coupled
Available Configurations
• GSX series stainless steel, double
• GR standard gear width
helical, rotary gear pumps
• GRW wide gears for high flows
• GRH narrow gears for high pressures
See Bulletin PS-60-4.
See Bulletin PS-60-4.
52 ® INSUROCK is a registered trademark of Richardson Company, Inc.
TSP MP1 MP1
Double-Suction, Multiphase Twin-Screw Systems Packaging
Twin-Screw

Overhung
Positive Displacement
– General Industry
— Screw
Standards Standards Standards
• API 676, latest ed. • API 676, latest ed. • Flowserve
• ASME
Operating Parameters Operating Parameters
• Flows to 2550 m3/h (11 200 gpm) • Flows to 2255 m3/h (9617 gpm) Features
• Pressures to 100 bar (1450 psi) • Pressures to 50 bar (720 psi) • Standard or custom engineered
• Temperatures to 450°C (842°F) • Temperatures to 450°C (842°F) system packaging available
• Speeds to 1800 rpm • Speeds to 2000 rpm • Driver options
• Viscosities to 55 million cP • Viscosities to 8000 cP −−Electric motor
• Slurry concentrations to 70% • Multiphase pumping to 100% GVF −−Electric motor with variable speed
by weight (gas volume fractions) drive (VSD)
−−Diesel or natural gas engine
Features Features • Complete piping systems
• Positive displacement timed • Non-contacting design with −−Suction, discharge, bypass and
two-screw one-piece pump shafts recycle piping
• Double-suction design • Three pumping locks for low −−Block, control and check valves
• Split bearing bracket for ease pulsation flow −−Filters and strainers
of maintenance • Through-bolt bearing bracket design −−Pressure, temperature and flow
• Versatile ISO 21049/API 682 • ISO 21049/API 682 seal chamber instrumentation
compliant stuffing box design with split brackets accommodates • Complete, integrated control systems
• Integral or pinned screw elements single and double cartridge seals −−PLC-based
• Spur-tooth timing gears • Double-suction design with low −−Controls for pump, valves,
• Chrome-plated pump bores NPSH capability instrumentation and alarms,
• Options • AGMA 11 helical timing gears VSD, etc.
– Fully external bearings and • Chrome-plated bores and −−Motor control center
timing gears hard-coated screws • Single and multiple skid options
– Internal bearings and timing gears • Options for integration of controls, pump
– Temperature control packages −−Multiple hard coatings for bores and piping
– Hopper-top construction and screws • Special enclosures for arctic-
– Vertical barge configuration −−Choice of materials, including NACE like conditions or other harsh
– Choice of materials −−Customized pitch environments
– Multiple hard coatings for bores −−Customized packaging
and screws −−Variable speed drive
−−Natural gas or diesel engine drive
See Bulletin PS-60-1.
Other Configurations
• High pressure: 100 bar (1450 psi)

See Bulletin PS-60-2. 53


YHT and HS VTE , VQE, V and VSE
Horizontal Reciprocating Vertical Reciprocating
OverhungDisplacement
Positive – General Industry
— Reciprocating

Standards Standards
• API 674, latest ed. • API 674, latest ed.
• ASME section III • ASME section III

Operating Parameters Operating Parameters


• 75 mm (3 in) to 250 mm • 140 mm (5.5 in) to 225 mm
(10 in) stroke (9 in) stroke
• Flows to 775 m3/h (3400 gpm) • Flows to 1140 m3/h (5000 gpm)
• Standard pressures to 555 bar • Standard pressures to 619 bar
(8030 psi); custom pressures to (8975 psi); custom pressures to
2070 bar (30 000 psi) 2070 bar (30 000 psi)
• Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 350°C (650°F) to 350°C (650°F)
• Power to 2560 kW (3430 hp) • Power to 3450 kW (4625 hp)
• Speeds to 530 rpm • Speeds to 360 rpm

Features Features
• Self-aligning plungers • Outboard packed inverted design
• Sectionalized fluid end components • Easily accessible stuffing box
• Fully enclosed power end with • Integrated suction and discharge
generous oil reservoir manifold
• Independent crosshead extension rod • Complete separation of liquid end
• Integrally cast and precision-machined from power end
cylindrical crosshead guides • Valve design suitable for conditions
• Triple lip seal at crosshead extensions of service
• Fully reversible crankshaft for V-belt • Spherical feature for plunger alignment
drive or direct coupling • Power-end maintenance
• Stuffing box assemblies individually inspection covers
bolted to fluid cylinder • Forced feed lubrication
• Splash-type or full-pressure • Options
lubrication system −−Spring-loaded packing
• Threaded primary drain −−Pulsation dampeners
• Options −−Sectionalized fluid ends
– Overhead motor mounting
– Spring-loaded stuffing box See Bulletin PS-70-1.
– Discharge pulsation dampeners

See Bulletin PS-70-1.


54
Overhung – General Industry

55
Specialty Products
Nuclear Pumps and Seals
DFSS 58
DVSS 58
N-Seal 58
WDF 58

Specialty Products
DVSR 59
CN 59
HDR 59
CA 60
CAM 60
CAV 60
EG 61
MEV 61

Extreme Temperature
WUC-LNG Cryogenic 62
VKW Cryogenic 62
TKW Cryogenic 62
Byron Jackson 62
SUBM Geothermal
Others
Hydraulic Decoking Systems 63
IPS Products 63
Pleuger WFSD 64
Azimuthing Thruster
DWEER™ 64
ERT 64
CVP 65
Barge Pump 65
Molten Salt VTP 65

57
DFSS and DVSS N-Seal WDF Nuclear
Nuclear Radially Split, Nuclear Mechanical Seals Vertical, Single-Stage
Single-Stage
Overhung Products
Specialty – General
— Industry
Nuclear Pumps and Seals

Standards Standards Standards


• ASME Section III, Class 1 • ASME Section III, Class 1 • ASME Section III, Class 2 and 3

Operating Parameters Operating Parameters Operating Parameters


• Flows to 24 500 m3/h (108 000 gpm) • Pressures to 150 bar (2175 psi) • Flows to 900 m3/h (4000 gpm)
• Heads to 250 m (820 ft) • Temperatures to 80°C (180°F) • Heads to 245 m (800 ft)
• Pressures to 170 bar (2500 psi) • Speeds to 1800 rpm
• Temperatures to 300°C (580°F) Services
• Speeds to 1800 rpm Services • Containment spray
• Power rating to 9400 kW (12 600 hp) • Primary coolant • Low-pressure safety injection
• Reactor recirculation • Residual heat removal
Services • Primary heat transport
• Primary coolant Features
• Reactor recirculation Features • Vertical, single-stage design
• Primary heat transport • Controlled leakage seal design • Bottom suction, horizontal discharge
• Design life of five years or • Forged diffuser casing design
Features 50 000 hours • Optimized hydraulic performance
• Fourth generation design • Reduced man-rem exposure   • Unique spacer coupling design
• One-piece cast pump casing • Unique one- or two-piece cartridge • Mechanical seal replacement without
• Double volute design case for BWR construction motor or casing cover removal
and PHWR • Two-, three- and four-stage • Upgraded rotor design
• Diffuser with torus-type design configurations – Radial bearing located between
casing for PWR • Assured redundancy with each stage coupling and seal
• Upgraded rotating element able to handle full system pressure – Reduced shaft deflection
– One-piece welded shaft-impeller- • Interchangeable stage components   – Improved pump and mechanical
journal assembly • Hydrodynamic seal face technology   seal life and reliability
– Fully machined and balanced as • Three different seal face lift designs • Cartridge mechanical seal
single rotating unit available   • Reduced assembly time
• Hydrostatic-pressurized radial bearing • Multiple seal face materials available
– Operates submerged in radioactive • Provisions for monitoring pressure, See Bulletin FPD-2.
system water at loop temperature temperature and flow at each stage
of approximately 300°C (580°F) • Internal screens for trapping particles
• Seal faces are supported by gaskets
See Bulletin FPD-2. to minimize pressure points and
deflection

See Bulletin PS-80-2.


58
DVSR Nuclear CN Nuclear HDR Nuclear
Radially Split, Volute Radially Split, Diffuser Radially Split, Volute
Casing, Single-Stage Casing, Single-Stage Casing, Single-Stage

Overhung Products
Specialty – General
— Industry
Nuclear Pumps and Seals
Standards Standards Standards
• ASME Section VIII • ASME Section VIII • ASME Section VIII

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4535 m3/h (19 945 gpm) • Flows to 5065 m3/h (22 300 gpm) • Flows to 5065 m3/h (22 300 gpm)
• Heads to 800 m (2625 ft) • Heads to 800 m (2625 ft) • Heads to 800 m (2625 ft)
• Pressures to 100 bar (1470 psi) • Pressures to 100 bar (1470 psi) • Pressures to 100 bar (1470 psi)
• Temperatures to 210°C (410°F) • Temperatures to 210°C (410°F) • Temperatures to 210°C (410°F)
• Power to 8000 kW (10 700 hp) • Power to 11 200 kW (15 000 hp) • Power to 11 200 kW (15 000 hp)
• Speeds to 6000 rpm • Speeds to 6000 rpm • Speeds to 6000 rpm

Services Services Services


• Reactor and steam generator feedwater • Reactor and steam generator • Reactor and steam generator
feedwater feedwater
Features
• Cast volute casing configuration Features Features
• Double cover design • Diffuser casing configuration • Volute casing configuration
• High-speed pump design • Forged barrel • Forged barrel
• Double-suction impeller • High-speed pump design • High-speed pump design
• Centerline mounted • Double-suction impeller • Double-suction impeller
• Pressure breakdown bushing or • Special impeller designs for low • Special impeller designs for low
mechanical seal NPSHA conditions NPSHA conditions
• Sleeve radial and tilting pad thrust • Centerline mounted • Centerline mounted
bearings standard • Pressure breakdown bushing or • Pressure breakdown bushing or
mechanical seal mechanical seal
See Bulletin FPD-2. • Sleeve radial and tilting pad thrust • Sleeve radial and tilting pad thrust
bearings standard bearings standard

See Bulletin PS-80-4.

59
CA Nuclear CAM Nuclear CAV Nuclear
Diffuser Casing, Diffuser Casing, Vertical, Double Case,
Multistage, Utility Barrel Multistage, Utility Barrel Multistage
Overhung Products
Specialty – General
— Industry
Nuclear Pumps and Seals

Standards Standards Standards


• ASME Section III, Class 2 and 3 • ASME Section III, Class 2 and 3 • ASME Section III, Class 2 and 3

Operating Parameters Operating Parameters Operating Parameters


• Flows to 5250 m3/h (23 000 gpm) • Flows to 45 m3/h (200 gpm) • Flows to 60 m3/h (265 gpm)
• Discharge pressures to 450 bar • Heads to 1920 m (6300 ft) • Heads to 2000 m (6560 ft)
(6500 psi) • Pressures to 235 bar (3410 psi) • Pressures to 235 bar (3410 psi)
• Temperatures to 250°C (480°F) • Temperatures to 120°C (250°F) • Temperatures to 100°C (212°F)
• Speeds to 6000 rpm • Speeds to 3600 rpm
Services
Services • CVCS charge Services
• Safety injection • Control rod drive • CVCS charge

Features Features Features


• Internal casing with segmented • Multistage, double case design • Multistage, double case design
stage elements • Unique, compact design • Barrel-rated at full discharge pressure
• Diffuser guide-vane construction • Modular impellers • Suction and discharge connections at
• Precision cast in-line impellers – Low-flow stability and reliability bottom of barrel
• Heavy-duty forged barrel with forged over a wide range of flows • Diffuser design with back-to-back
steel discharge cover – No surging or pulsations impeller mounting to minimize thrust
• Balance drum and sleeve, made • Ball-ball construction • Cartridge mechanical seal
from hardened stainless forgings • Dry disk spacer coupling • Thrust bearings provided in either
• Ball thrust and ball radial bearings • Flanged axial thrust balancing device pump or motor as required
• Fan-cooled bearing housings • Modularized assembly and • Spacer coupling
• Renewable casing rings and sleeves disassembly may be conducted
• Ground forged steel shafting without the use of a torch See Bulletin FPD-2.
• Cartridge seals • Forged barrel with no
attachment welds
See Bulletin FPD-2. • Cartridge mechanical seals with
no attachment welds
• No auxiliary cooling required

See Bulletin FPD-2.

60
EG Nuclear MEV Nuclear
Radially Split, Vertical, Single-Stage
Double-Suction

Overhung Products
Specialty – General
— Industry
Nuclear Pumps and Seals
Standards Standards
• ASME Section III, Class 3 • ASME Section III, Class 3

Operating Parameters Operating Parameters


• Flows to 4000 m3/h (17 610 gpm) • Flows to 5400 m3/h (23 760 gpm)
• Heads to 60 m (200 ft) • Heads to 50 m (160 ft)
• Pressures to 14 bar (200 psi) • Pressures to 14 bar (200 psi)
• Temperatures to 80°C (180°F) • Temperatures to 80°C (180°F)
• Power to 950 kW (1275 hp) • Speeds to 3600 rpm
• Speeds to 3600 rpm
Services
Services • Essential and non-essential
• Component cooling water service water

Features Features
• Cast volute casing • Cast casing and cover
• Double cover design • Bottom suction, horizontal discharge
• Double-suction impeller configuration
• Centerline mounting • Single-stage, enclosed impeller
• Side suction and side discharge • Fabricated motor stand
located above the mounting feet • Cartridge mechanical seal
• Cartridge mechanical seal • Radial roller and double ball
• 360° bearing housings thrust bearings
• Ball radial and ball thrust bearings • Grease-lubricated bearings

See Bulletin FPD-2. See Bulletin FPD-2.

61
WUC-LNG Cryogenic (VS6) VKW and TKW Cryogenic Byron Jackson SUBM
Vertical, Double Case, Liquid Expander (VS6) Geothermal Deep-Well
Multistage Double Case, Multistage, Submersible
Electric Generator
Overhung Products
Specialty – General
— Industry
Extreme Temperature Pumps

Standards Standards Standards


• ISO 13709/API 610 (VS6), • ISO 13709/API 610 (VS6), • IEC/VDE and other certifications
latest edition latest edition
• ASME Sections VIII and IX • ASME Sections VIII and IX Operating Parameters
• German Pressure Vessel • Flows to 720 m3/h (3170 gpm)
Association (AD) Operating Parameters • Heads to 800 m (2625 ft)
• British Standard BS 5500 • Expander flows to 2500 m3/h • Temperatures to 160°C (320°F)
• Compliance with Pressure Equipment (11 000 gpm) • Motor sizes to 1500 kW (2000 hp)
Directive 97/23/EC • Inlet pressures to 70 bar (1000 psi) • Speeds from 2900 to 3500 rpm
• Temperatures to -180°C (-290°F) • Inner well diameters from 340 mm
Operating Parameters • Power to 3 MW (4000 hp) (13-3/8 in) to 508 mm (20 in)
• Flows to 3000 m3/h (13 000 gpm) • Runaway speed to 5400 rpm
• Heads to 1200 m (3900 ft) Features
• Pressures to 200 bar (3000 psi) Features • Pump and motor design for
• Temperatures from -200°C (-328°F) • Variable or fixed geometry geothermal application
to -45°C (-50°F) • Externally driven remote and local • Oil-filled motor with self-contained
controlled variable wickets force feed, filtered, cooled oil
Features • Optimal isentropic efficiency circulation system
• Coffer dam system • Overall improvement of compressor • Vacuum pressure impregnated (VPI)
• Radial or mixed flow hydraulics power efficiency epoxy, Class F insulation system
• Low suction velocity can design • Air-cooled generator • Class C winding insulation system
• Optional axial thrust tilting pad • Temperature reduction through • Double cable plug construction
bearing configuration liquid expansion • Double-acting thrust bearing system
• Stiff shaft design • Additional electric generation • Dynamically balanced heavy-duty,
• ISO 21049/API 682 compliant • Low vibration high-efficiency impellers
mechanical seal chamber • Low noise level • Optional variable frequency
• Flanged spacer coupling • State-of-the-art gas seal • Choice of materials
• Screen-type, non-sparking • Optimum specific speed selection • Double mechanical seal
coupling guard • Motor design with breather diaphragm
• Inside drain line Available Configurations for pressure compensation
• Casing and impeller wear rings • TWK variable geometry, double • Non-return design for high pressure
• Reinforced motor stand case, multistage, electric generator • Downhole monitoring system
• Optional inducer • VKW fixed geometry, double case,
multistage, electric generator Other Configurations
Related Configurations • Byron Jackson SUBM deep-well
• WUC (VS6) double case, See Bulletin PSS-90-7.1. submersible (oil-filled design)
multistage
62 See Bulletin PSS-40-9.1.
Hydraulic Decoking Systems IPS Equipment Monitoring
and Control Products

Overhung Products
Specialty – General
— Industry
Others
Flowserve Automated Hydraulic • Provides greater system automation Intelligent Process Solutions (IPS)
Decoking Systems and improved efficiency while • Family of equipment monitoring
• Increase delayed coking unit (DCU) improving operator safety, reducing and control products that helps to
capacity and improve operator safety cycle time and easing maintenance proactively manage plant assets
• Installed in more than 95% of the • Mode shifting helps to free impeded −−Collect key system parameters
world’s DCUs tools from slumped beds −−Analyze and synthesize data into
• Complete systems with virtually all actionable information
equipment needed to operate and Advanced Cutting Control −−Protect process equipment via
control the hydraulic decoking process • Complete systems and enclosures automated responses
• Extensive aftermarket support to monitor and control the operations −−Transmit information to enable a
including specialists to evaluate • Continuous feedback signals timely manual response
system performance, improve indicate equipment and drum status • Increase uptime
reliability, and recommend operational (i.e., position in drum, rotational • Reduce operating costs
and safety best practices speed, wore rope tension, etc.)
• Embedded intelligence to process IPS Wireless
Complete Coke Cutting Systems data for monitoring and control; • Cost-effective and scalable data
• Jet pump train: ISO 13709/API 610 operator interface only required acquisition system
(BB5) jet pump, driver, lube oil skid for sequence exception • Open platform architecture
and control system panel • Video and acoustic equipment to • Omni-directional technology
• Coke cutting system: decoking monitor cutting deck operations and
control valve, AutoShift™ combination coke chute conditions IPS APEX
cutting tool, rotary joint, isolation and • Remote winch and rotary joint • Advanced diagnostics
bleed valves, drill stem, tool guide and operation • Intelligent control algorithms protect
enclosure and high-pressure hose • Remote sensing of cutting jet against high-risk process conditions
• Cutting assembly lifting system: impingement on the coke drum
crosshead, free-fall arresters, winches • Interlocking safety systems IPS Tempo
and winch controls, pulley blocks, • IPS APEX™ data monitoring, • Variable frequency drive
and latch mechanism to stow transmission and control systems • Intelligent system optimization
the crosshead
• Automation, controls and Online Assurance Programs IPS Power Monitor
instrumentation • Access to data aggregation tools via • Monitors actual power usage
the Technology Advantage™ Portal • Programmable start-up delay and
AutoShift Combination Cutting Tool • Enable experts to monitor, diagnose low and high trip points
• Removes the operator from the and communicate operating
cutting deck solutions to increase unit uptime See Bulletin PS-90-11.
• Mode shifting is accomplished
automatically and remotely by water See Bulletin PS-90-6.
pressurization and depressurization
63
Pleuger WFSD DWEER TM
ERT
Azimuthing Thruster Dual Work Exchange Energy Recovery Turbine
Energy Recovery
Overhung Products
Specialty – General
— Industry
Others

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Applications Operating Parameters Operating Parameters


• Semi-submersible drilling rigs • Brine flows to 350 m3/h (1.4 MGD); • Brine flow to 1200 m3/h (5280 gpm)
• Floating production, storage and greater flows can be achieved • Pressures to 80 bar (2715 ft)
offloading vessels by placing multiple DWEER units • Efficiency up to 90%
• Drill ships in parallel • Power to 1500 kW (2025 hp)
• Crane vessels and pipelay vessels • Pressures to 75 bar (1090 ft) • Special designs available on request

Features Features Features


• Up to 5 m (16.5 ft) propeller diameter • Highest efficiency energy recovery • Specially designed for sea water
• Up to 4500 kW (6000 hp) input device available reverse osmosis (SWRO) applications
• 4- or 5-blade fixed pitch propeller • Noise levels below 83 dBa • Standardized product line
• 7° tilted propeller shaft • Self-adjustable to changing operating • Wetted parts in super duplex
−−Propulsion and steering with thrust conditions stainless steel and non-metallics
in any direction • Super duplex stainless steel or • Proven long-term reliability with more
−−Minimal thruster-hull and fiber-reinforced plastic pressure than 25 years of operating experience
thruster-thruster interaction for vessel • Simple plant integration and control
higher net thruster output • No leakage lubrication required • Horizontal split casing
−−Mounting and dismantling • LinX™ valve regulates flow into • External standard bearings
underwater without dry-docking vessels • Labyrinth double seals
−−Customization to meet specific • Proven long-term reliability • Flat operating curve over typical RO
application needs • Capable of passing solids performance range
• Duplex thrust bearing allows (no additional strainers required) • No mixing, overflush or leakage
windmilling at any speed • System responsibility with
• Automatic pressure compensation integrated controls See Bulletin FPD-18.
system adapts differential pressure • Slow operating speed
to draft • Smooth increase and decrease of
• Fully flooded gear housing provides system pressure during startup and
optimum lubrication shutdown
• Easy underwater mounting; secured
during installation by hydraulically See Bulletin FPD-18.
operated locking mechanism
• Fully redundant closed-loop hydraulic
steering system as standard

See Bulletin PSS-90-8.1.


64
CVP Barge Pump Molten Salt VTP
Vertical, Concrete Volute

Overhung Products
Specialty – General
— Industry
Others
Standards Standards Standards
• Flowserve • Flowserve • Flowserve
• Hydraulic Institute
Operating Parameters Operating Parameters
Operating Parameters • Flows to 1020 m3/h (4500 gpm) • Flows to 13 600 m3/h (60 000 gpm)
• Flows to 200 000 m3/h (800 000 gpm) • Heads to 185 m (600 ft) • Heads to 530 m (1740 ft)
• Heads to 60 m (197 ft) • Pressures to 8.6 bar (125 psi) • Pressures to 100 bar (1450 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 600°C (1100°F)
Features to 230°C (450°F) • Settings to 20 m (65 ft)
• Vertical dry-pit design • Discharge flanges to 250 mm (10 in)
• Removable metallic pump pullout Features
unit within a concrete volute Features • Low pump submergence allows for
• Suction bell connected to preformed • Pollution prevention design greater energy generation
high-efficiency, vortex-free concrete • Discharge head with access ports • Low NPSHR for enhanced suction
suction box • Rabbeted-fit motor shaft to headshaft performance
• Open mixed flow and closed mixed • 1.5 m (5 ft) column pieces with • Excellent heat dissipation prevents
flow impeller options integrally fabricated bearing support distortion at high temperatures
• Dry shaft design • Automatic stuffing box bleed-off • Advanced fluid sealing system
• No submerged bearings and valved drain line • Materials engineered to equalize
• Bearings and sealing systems • Special low NPSH priming thermal growth and forestall distortion
easily accessible stage impeller • Wet-pit or tank-mounted
• Prefabricated concrete segments • Semi-open series stage impeller • Dynamically balanced enclosed
• Highly corrosion and erosion resistant • Automatic air separation chamber impellers
• Liquidyne® or mechanical shaft seal with continuous seal • Flanged column pipe with open
• Inflatable static seal lineshaft construction
• Engineered to customer specifications See Bulletin PSS-40-7.2. • Product lubricated bearings
• Cooling fan/disc
Available Configurations • Drain tubes
• BSV open mixed flow impeller design • Other options
• BCV closed mixed flow impeller design −−Integral axial thrust bearing
−−Thrust-balanced impeller
See Bulletin PS-40-1. −−Coupling bellows
® Liquidyne is a registered trademark of IHC.
−−ISO 13709/API 610 construction

Related Configurations
• FRBHJC cantilever sump
• CPXV chemical sump

See Bulletin FPD-16. 65


Additional Information
Services and Solutions 68
Other Flowserve Products 70
Reference Sources 71

Additional Information

67
Services and Solutions for the Global Infrastructure Markets
The business and operational challenges within
a process plant are numerous. Plant operators
face the pressures of increased productivity and
profits that are seemingly at odds with the every-
day realities of decreased operating budgets,
rising energy costs and increasing operational
costs. But Flowserve Services and Solutions can
help relieve the stresses and reduce the life cycle
90%
Operating Cost

costs associated with the most important aspects


of plant operation. Dedicated to delivering the
highest quality support, Flowserve Services and
Integrated Solutions That Support
Solutions integrates hydraulic, mechanical, and
the Complete Life Cycle
Typically, 90% of the total life cycle cost (LCC)
materials engineering knowledge with creative
of a flow management system is accumulated
operating and business solutions to: after the equipment is purchased and installed.
• Improve equipment reliability and performance Flowserve offers a comprehensive suite of
services and solutions designed to provide
• Reduce energy consumption customers with unprecedented value and cost
• Manage inventories savings throughout the life span of the system.
• Maintain flow management equipment • Asset Management and Optimization
• Engineering and Technical Services
• Education and Training
• Aftermarket Parts and Services

68
flowserve.com

Asset Management and Optimization Education and Training


Flowserve has developed the human resources, Flowserve offers a wide range of innovative
technology platforms and business alliances to help programs to help plant operators, reliability
customers realize more payback from their plant assets. specialists, engineers and maintenance personnel
• Business Assessments — ­­ Flowserve business deepen their understanding of process systems.
consultants can benchmark operational performance, • Customer Site — Flowserve can design, develop,
define the key metrics and implement the necessary and deliver training programs tailored specifically
steps to achieve specific goals. around the people, equipment and processes at a
• Asset Data Management — By employing customer’s facility.
sophisticated tools and technologies to collect, • Learning Resource Center — At its state-of-the-art
examine and understand data, Flowserve enables Learning Resource Centers, Flowserve provides
customers to reveal hidden opportunities for asset hands-on training and instruction in the principles
improvement. of equipment operation, maintenance and reliability.
• Asset Optimization Solutions — Flowserve offers a • Online — Flowserve offers Web-based modules
suite of performance-based contract services to with online testing and data tracking to ensure
address the key business and operational challenges comprehension of the most important principles.
of plant managers.
Aftermarket Parts and Services
Engineering and Technical Services Investments in well-equipped Quick Response
With unrivaled engineering and technical resources in Centers, mobile service fleets, and advanced
more than 55 countries, Flowserve delivers value-added manufacturing technologies along with the unrivaled
solutions that improve operational performance and expertise of its engineers, technicians and craftsmen
increase revenues for its customers. enable Flowserve to address virtually every service
• Engineering Support — Flowserve engineers can requirement for process equipment, on- or off-site,
engage remotely or on-site to support grassroots regardless of OEM.
project planning, system design or project • Repair and Maintenance — From machining to
management requirements. mechanical upgrades to on-site management,
• Technical Assessments — Flowserve can perform Flowserve repair and maintenance services focus
comprehensive system audits to identify operational on improving equipment performance while
issues that may be constraining output or elevating reducing downtime and costs.
operating costs and propose solutions based upon life • Replacement Parts and Components — Through
cycle cost (LCC) calculations. quick response programs, rapid prototyping, and
• Equipment Performance Improvements — Flowserve other innovative approaches, Flowserve can supply
routinely implements LCC-justified solutions to customers with the quality parts needed to keep
improve equipment performance, system throughput operations running smoothly and profitably. 69
and unit profitability.
Providing Complete
Fluid Motion
Control Equipment
and Services

Other Flowserve Products


Flowserve has the systems, products, and Flowserve Valves
experience to help processes run smarter, safer With the industry’s most complete range of valves,
and more efficiently. In addition to its extensive actuators, positioners, controls, switches and steam
pump product line, Flowserve offers high-quality systems, Flowserve provides customers a one-stop
solution for their flow control needs.
seals and valves.
With comprehensive research and development,
engineering and global support, Flowserve offers
Flowserve Seals valve applications solutions from simple isolation
Flowserve manufactures and markets highly engineered service to intelligent process control.
mechanical shaft seals for containing corrosive, volatile, To learn more about Flowserve valves and seals,
abrasive, precious or flammable fluid. They are used on visit www.flowserve.com.
pumps and other rotating equipment.
The complete seal line includes cartridge, dry-running,
metal or elastomer bellows, split and zero-emission gas
barrier seals. Offering innovative seal design and
service on demand, Flowserve is
committed to the development of
new technologies to further reduce
maintenance and operating costs
for its customers.

70
flowserve.com

Reference Sources
FlowSelex™ Interactive Pump Cameron Hydraulic Data
Selection Application First published in 1926 and now in
FlowSelex is a Web-based interactive pump selection its 19th edition, the Cameron
program that allows users to access an extensive Hydraulic Data book is an
database of Flowserve pump sizing information indispensable aid to engineers
anytime, anywhere. involved with the specification,
selection and application of pumping
This versatile tool delivers a wide range of information, equipment. This comprehensive
from pump descriptions and operating parameters to reference tool includes:
custom application package specifications with
• Hydraulic principles and formulae
supporting technical documentation, including:
• Friction data
• Performance curves • Properties of common liquids
• Hydraulic data sheets • Steam and electrical data
• General arrangement drawings • Weights, dimensions, and ratings of pipe
• Construction data sheets flanges and fittings
• Metric conversions
FlowSelex can be accessed at
www.Flowserve.com/FlowSelex. To obtain a copy of the Cameron Hydraulic Data
book, visit: www.cameronbook.com.

Pump Engineering Manual


This publication is devoted to
explaining centrifugal pump principles.
It covers the basics, from application
analysis and affinity laws through
hydraulics and mechanical phenomena
to troubleshooting.
To obtain a copy of the Pump
Engineering Manual, visit:
www.cameronbook.com.

71
Index

A E L
AFV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
APKC (see APKD) . . . . . . . . . . . . . . . . . . . . . . . 43 ECPJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 LLR (see LR) . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
APKD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 EG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 LNN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
ERPN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 LPN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
B ERT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 LR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Barge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 ESP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 LRV (see LR). . . . . . . . . . . . . . . . . . . . . . . . . . . 28
BCV (see CVP). . . . . . . . . . . . . . . . . . . . . . . 41, 65
BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 F M
BSV (see CVP). . . . . . . . . . . . . . . . . . . . . . . 41, 65 F-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Byron Jackson SUBM (Geothermal). . . . . . . 62 FRBH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Mark 3 ASME Standard. . . . . . . . . . . . . . . . 10
Byron Jackson SUBM (Oil-Filled Design). . . 44 FRBHJC . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 46 Mark 3 In-Line (ASME) . . . . . . . . . . . . . . . . 11
Mark 3 ISO Close Coupled. . . . . . . . . . . . . 13
C G Mark 3 ISO Recessed Impeller. . . . . . . . . 12
CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 GA Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Mark 3 ISO Self-Priming. . . . . . . . . . . . . . . 12
CAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Gearex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Mark 3 ISO Standard . . . . . . . . . . . . . . . . . . 12
CAV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 GR Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Mark 3 Lo-Flo (ASME). . . . . . . . . . . . . . . . . 10
CHTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Guardian. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Mark 3 Recessed Impeller (ASME) . . . 11
CN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Mark 3 Unitized Self-Primer (ASME). . . 10
CPXS Magnetic Drive. . . . . . . . . . . . . . . . . . 13 H
ME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
CPXV Chemical Sump. . . . . . . . . . . . . . 13, 48 HDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
CSB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 HDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 MENBLOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
CSX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 HDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 MEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
CVP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41, 65 HDX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 MF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
HDX-TT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 MFV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
D HED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 MJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
D800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 HED-DS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 MJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
DFSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 HPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DMX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 HPXM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Drain-Titan. . . . . . . . . . . . . . . . . . . . . . . . 47, 49 HS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 MNR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 HSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MNV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
DSVP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 HSO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Molten Salt VTP. . . . . . . . . . . . . . . . . . . . . . . 65
DVSH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 HWMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 MP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
DVSR (non-nuclear). . . . . . . . . . . . . . . . . . . 31 HWMA2 (see HWMA). . . . . . . . . . . . . . . . . . . . 17 MP1 Systems Packaging . . . . . . . . . . . . . . 53
DVSR (nuclear) . . . . . . . . . . . . . . . . . . . . . . . 59 Hydraulic Decoking Systems. . . . . . . . . . . 63 MPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DVSS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
DWEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 I
IPS Products. . . . . . . . . . . . . . . . . . . . . . . . . . 63
72
flowserve.com

MSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 R VSMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
MSP2 (see MSP). . . . . . . . . . . . . . . . . . . . . . . . 18 R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 VTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
MSX. . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 44, 47 RJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 VTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
MVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 RJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
MVX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 W
S WCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
N WD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
SMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
NM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SMX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 WDF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
N-Seal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 SUBM WDX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
(see Byron Jackson SUBM or Pleuger SUBM) . . 44 WFSD Thruster
P (see Pleuger WFSD Azimuthing Thruster) . . . . . 64
PHL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 WIK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Pleuger SUBM (Water-Filled Design) . . . . 44 T WIKO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Pleuger WFSD Azimuthing Thruster. . . . 64 Terra-Titan. . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 WMA (see HWMA). . . . . . . . . . . . . . . . . . . . . . . 17
Polybase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Titan Slurry. . . . . . . . . . . . . . . . . . . . . . . . . . . 19 WMA2 (see HWMA) . . . . . . . . . . . . . . . . . . . . . 17
PolyChem GRP . . . . . . . . . . . . . . . . . . . . . . . 14 TKW Cryogenic Liquid Expander. . . . . . . 62 WNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PolyChem M-Series. . . . . . . . . . . . . . . . . . . 15 TSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 WNC-HP (see WNC). . . . . . . . . . . . . . . . . . . . . 35
PolyChem S-Series. . . . . . . . . . . . . . . . . . . . 14 WTB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
PolyChem VGRP . . . . . . . . . . . . . . . . . . . 14, 48
U WUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Polyshield . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 UZDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 WUC-LNG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
PVML. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 WUJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
V
PVXM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 WX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
WXB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Q VCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
WXB-B (see WXB). . . . . . . . . . . . . . . . . . . . . . . 35
QL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 VKW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
WXH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
QLC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 VPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
QLQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 VQE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Y
QLQC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 VSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 YHT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

73
USA and Canada
Flowserve Corporation
5215 North O’Connor Blvd.
Suite 2300
Irving, Texas 75039-5421 USA
Telephone: +1 937 890 5839

Europe, Middle East, Africa


Flowserve Corporation
Parallelweg 13
4878 AH Etten-Leur
The Netherlands
Telephone: +31 76 502 8100

Latin America
Flowserve Corporation
Martín Rodriguez 4460
B1644CGN-Victoria-San Fernando
Buenos Aires, Argentina
Telephone: +54 11 4006 8700
Telefax: +54 11 4714 1610

Asia Pacific
Flowserve Pte. Ltd.
10 Tuas Loop
Singapore 637345
Telephone: +65 6771 0600
Telefax: +65 6862 2329

Bulletin FPD-100m (E) May 2014. © 2014 Flowserve Corporation

To find your local Flowserve representative:

For more information about Flowserve Corporation,


visit www.flowserve.com or call +1 937 890 5839.

flowserve.com

You might also like