Generator Sets

60 Hz
Powered By:
160 kWe - 270 kWe
(200 kVa - 338 kVa)

Generation II
Output Ratings
Tradewinds Model TJ 160 II - 60 TJ 184 II - 60 TJ205 II - 60 TJ 226 II - 60 TJ 270 II - 60

Engine Model 6068H 6068H 6068H 6081A 6081H


Engine Performance 6068H275 6068HF150 6068HF475 6081AF001 6081HF001
Emissions Cert. Level T2 T2 T2 T1 T1

Alternator Type Magnaplus Magnaplus Magnaplus Magnaplus Magnaplus


Alternator Model 431PSL6202 431PSL6204 431PSL6206 431PSL6206 432PSL6210

60 Hz - 3 Phase (12 Lead Reconnectable Generator)

Standby kWe Output 160 184 205 226 270


Continous kwe Output 148 160 180 190 228

Standby kVa Output 200 230 256 283 338


Continous kVa Output 185 200 225 238 285

60 Hz - 1 Phase Output Ratings (3 phase generator set reconnected to 1 phase)

kWe Standby 125 140 175 175 206


kWe Continous 120 133 165 165 200

kVa Standby 156 175 219 219 258


kVa Continous 150 166 206 206 250

60 Hz - 1 Phase Output Ratings (4 lead dedicated single phase or oversized 12 lead generator)

Tradewinds Model TJD163 II - 60 TJD184 II - 60 TJD205 II - 60 TJD226 II - 60 *TJS250 II - 60

Alternator Type Magnaplus Magnaplus Magnaplus Magnaplus Magnaplus


Alternator Model 431PSL6224 431PSL6226 432PSL6228 432PSL6228 433PSL6216

kWe Standby 165 185 205 225 250


kWe Continous 155 175 180 210 240

kVa Standby 206 231 256 281 313


kVa Continous 194 219 225 263 300
* Oversized 12 lead reconnectable generator connected for 1 phase output

03 / TJ 160 - 270 II - 60 www.tradewindspower.com Page 1 of 3


Generator Sets
60 Hz
Powered By:
160 kWe - 270 kWe
(200 kVa - 338 kVa)

Generation II
Generator Set and Engine Standard Features

Generator Set Standard Features


•Tropicalized cooling system rated for up to 122°F (50°C) ambient temperature.
•Radiator mounted on vibration isolators for maximum durability.
•Duralite air cleaner for easier maintenance.
•Fan and belt guards for operator safety.
•12 volt D.C. electrics (battery, starter, battery charging alternator, and control panel primary circuits).
•Auto start with engine shut down protection from over speed, high coolant temperature, low oil pressure,
under frequency, excessive crank attempts.
•Engine and alternator mounted on vibration isolators for increased durability, reduced noise and vibration.
•Generator set mounted on cross members for installation ease and flexibility.
•All generator sets are tested at .8 power factor and full load capacity prior to shipping.
•Limited Warranty of 1 year with unlimited hours or 2 years up to 2,000 hours.

Engine Standard Specifications


•Make - John Deere
•Models - 6068H, 6081H, or 6081A
•Displacement: For 6068 - 6.8 Liters ( 415 cu. In.) or for 6081 - 8.1 Liters ( 496 cu. In.)
•Aspiration: 6068H & 6081H (Turbo charged and air to air after cooled) or for 6081A (Turbo Charged and
water to air aftercooled).
•6 cylinders in line.
•Low friction high ring pistons with 3 rings provide low emissions, low fuel and oil consumption.
•Replaceable wet type cylinder liners with top liner cooling for longer life and rebuildable to original
specifications.
•Dynamically balanced crankshaft with induction hardened journals for long hours of reliable service.
•Seven main bearings with large main and connecting bearing surface areas for durability.
•Poly-vee belt drive with automatic tensioner for longer life and reduced maintenance.

•View engine model and engine performance spec sheets for a complete list of features and
specifications.

03 / TJ 160 - 270 II - 60 www.tradewindspower.com Page 2 of 3


Generator Sets
60 Hz
Powered By:
160 kWe - 270 kWe
(200 kVa - 338 kVa)

Generation II
Generator and Panel Standard Features

Alternator Standard Specifications


•Type: Brush less air cooled, external voltage regulated.
•Insulation NEMA class H rated 150°C standby and 125°C continuos.
•Insulation is of multiple dips and bakes of 100% solids epoxy.
•Coupling: Flexible disc, single bearing sealed for life of unit.
•12 lead re-connectable.
•Voltage Regulator: SE350 with voltage control accuracy of 1%.
•Over speed capacity of 25% at 2250 rpm.

•View alternator type and alternator model data sheets for a complete list of features and
specifications.

Standard Control Panel Features


•Three modes of operation (Stop, Manual, and Auto) with one push button for each provide simple operation.
•Automatic start with 3 attempts and crank disconnect.
•Low oil pressure and high coolant temperature shutdown protection.
•Overspeed and underspeed (frequency) protection.
•Charge fail alarm.
•Two fully configurable auxiliary inputs.
•All alarms are indicated by high visibility LED’s.
•Microprocessor solid state design for maximum reliability.

•View control panel data sheet for a complete list of of features and specifications.

Check our generator set options brochure for a list of available options.

Tradewinds Power Corp can custom build a generator set to meet your specific needs.
Please contact one of our sales representatives for details.
03 / TJ 160 - 270 II - 60 www.tradewindspower.com Page 3 of 3