You are on page 1of 8

WELLHEAD API-14B CRITICAL FUNCTION TEST

Well No.: W-0224 (DD-1P)


Date of Test: 20-Oct-17
SITHP: 2,727 Kpag SITHT: 29.0 ºC
SIBHP: 6,016 Kpag SIBHT: 78.8 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.: SDV-22378
Operations: 1. Differential Pressure 230 psi
2. Closure time 2 seconds
3. Leak rate test 14 (psi / 10 min)
Results/Comments: Bad passing, exceed API 14B limitation

Valve Name: Wing Valve


Tag No.: WSV-02379
Operations: 1. Differential Pressure 395 psi
2. Closure time 38 seconds
3. Leak rate test 1 (psi / 10 min)
Results/Comments:

Valve Name: Swap Valve


Tag No.: HV-02014
Operations: 1. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.: XV-04462
Operations: 1. Differential Pressure 516 psi
2. Closure time 2 seconds
3. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.: XV-04463
Operations: 1. Differential Pressure 185 psi
2. Closure time 2 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.: SSV-02377
Operations: 1. Differential Pressure 380 psi
2. Closure time 42 seconds
3. Leak rate test 4 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.: HV-02013
Operations: 1. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.: SCSSV-02375
Operations: 1. Differential Pressure 380 psi
2. Closure time 2 seconds
3. Leak rate test 1 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
WELLHEAD API-14B CRITICAL FUNCTION TEST
Well No.: W-0227A (DD-2P)
Date of Test: 20-Oct-17
SITHP: 2,520 Kpag SITHT: 29.5 ºC
SIBHP: 13,331 Kpag SIBHT: 78.3 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.: SDV-22381
Operations: 1. Differential Pressure 650 psi
2. Closure time 2 seconds
3. Leak rate test 20 (psi / 10 min)
Results/Comments: Bad passing, exceed API 14B limitation

Valve Name: Wing Valve


Tag No.: WSV-02397
Operations: 1. Differential Pressure 360 psi
2. Closure time 31 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Swap Valve


Tag No.: HV-02023
Operations: 1. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.: XV-04468
Operations: 1. Differential Pressure 320 psi
2. Closure time 2 seconds
3. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.: XV-04469
Operations: 1. Differential Pressure 300 psi
2. Closure time 2 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.: SSV-02395
Operations: 1. Differential Pressure 350 psi
2. Closure time 34 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.: HV-02022
Operations: 1. Leak rate test 9 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.: SCSSV-02393
Operations: 1. Differential Pressure 420 psi
2. Closure time 2 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
WELLHEAD API-14B CRITICAL FUNCTION TEST
Well No.: W-0222 (DD-3P)
Date of Test: 20-Oct-17
SITHP: 1,734 Kpag SITHT: 29.4 ºC
SIBHP: 11,889 Kpag SIBHT: 72.8 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.:
Operations: 1. Differential Pressure 623 psi
2. Closure time 2 seconds
3. Leak rate test 34 (psi / 10 min)
Results/Comments: Bad passing, exceed API 14B limitation

Valve Name: Wing Valve


Tag No.:
Operations: 1. Differential Pressure 250 psi
2. Closure time 39 seconds
3. Leak rate test 1 (psi / 10 min)
Results/Comments:

Valve Name: Swap Valve


Tag No.:
Operations: 1. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.:
Operations: 1. Differential Pressure 238 psi
2. Closure time 2 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.:
Operations: 1. Differential Pressure 230 psi
2. Closure time 2 seconds
3. Leak rate test 4 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.:
Operations: 1. Differential Pressure 242 psi
2. Closure time 48 seconds
3. Leak rate test 10 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.:
Operations: 1. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.:
Operations: 1. Differential Pressure 235 psi
2. Closure time 2 seconds
3. Leak rate test 1.0 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
WELLHEAD API-14B CRITICAL FUNCTION TEST
Well No.: W-0225 (DD-4P)
Date of Test: 20-Oct-17
SITHP: 1,720 Kpag SITHT: 29.1 ºC
SIBHP: 12,965 Kpag SIBHT: 72.8 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.: SDV-22380
Operations: 1. Differential Pressure 457 psi
2. Closure time 2 seconds
3. Leak rate test 40 (psi / 10 min)
Results/Comments: Bad passing, exceed API 14B limitation

Valve Name: Wing Valve


Tag No.: WSV-02385
Operations: 1. Differential Pressure 260 psi
2. Closure time 30 seconds
3. Leak rate test 4 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Swap Valve


Tag No.: HV-02017
Operations: 1. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.: XV-04464
Operations: 1. Differential Pressure 243 psi
2. Closure time 2 seconds
3. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.: XV-04465
Operations: 1. Differential Pressure 230 psi
2. Closure time 2 seconds
3. Leak rate test 6 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.: SSV-02383
Operations: 1. Differential Pressure 251 psi
2. Closure time 35 seconds
3. Leak rate test 1 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.: HV-02016
Operations: 1. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.: SCSSV-02381
Operations: 1. Differential Pressure 240 psi
2. Closure time 2 seconds
3. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
WELLHEAD API-14B CRITICAL FUNCTION TEST
Well No.: W-0227B (DD-6P)
Date of Test: 20-Oct-17
SITHP: 1,915 Kpag SITHT: 29.4 ºC
SIBHP: 12,462 Kpag SIBHT: 75.6 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.: SDV-22379
Operations: 1. Differential Pressure 550 psi
2. Closure time 2 seconds
3. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Wing Valve


Tag No.: WSV-02403
Operations: 1. Differential Pressure 274 psi
2. Closure time 29 seconds
3. Leak rate test 4 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Swap Valve


Tag No.: HV-02026
Operations: 1. Leak rate test 6 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.: XV-04470
Operations: 1. Differential Pressure 269 psi
2. Closure time 2 seconds
3. Leak rate test 10 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.: XV-04471
Operations: 1. Differential Pressure 253 psi
2. Closure time 2 seconds
3. Leak rate test 6 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.: SSV-02401
Operations: 1. Differential Pressure 262 psi
2. Closure time 42 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.: HV-02025
Operations: 1. Leak rate test 6 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.: SCSSV-02399
Operations: 1. Differential Pressure 268 psi
2. Closure time 2 seconds
3. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
WELLHEAD API-14B CRITICAL FUNCTION TEST
Well No.: W-0223A (DD-7P)
Date of Test: 20-Oct-17
SITHP: 2,279 Kpag SITHT: 29.4 ºC
SIBHP: 13,924 Kpag SIBHT: 77.8 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.: SDV-02380
Operations: 1. Differential Pressure 653 psi
2. Closure time 2 seconds
3. Leak rate test 53 (psi / 10 min)
Results/Comments: Bad passing, exceed API 14B limitation

Valve Name: Wing Valve


Tag No.: WSV-02367
Operations: 1. Differential Pressure 320 psi
2. Closure time 28 seconds
3. Leak rate test 4 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Swap Valve


Tag No.: HV-02008
Operations: 1. Leak rate test 11 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.: XV-04458
Operations: 1. Differential Pressure 304 psi
2. Closure time 2 seconds
3. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.: XV-04459
Operations: 1. Differential Pressure 296 psi
2. Closure time 2 seconds
3. Leak rate test 5 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.: SSV-02365
Operations: 1. Differential Pressure 308 psi
2. Closure time 39 seconds
3. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.: HV-02007
Operations: 1. Leak rate test 7 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.: SCSSV-02363
Operations: 1. Differential Pressure 330 psi
2. Closure time 2 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
WELLHEAD API-14B CRITICAL FUNCTION TEST
Well No.: W-0223B (DD-9P)
Date of Test: 20-Oct-17
SITHP: 7,659 Kpag SITHT: 29.7 ºC
SIBHP: 14,574 Kpag SIBHT: 83.1 ºC
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: Gaslift SDV Valve


Tag No.: SDV-22377
Operations: 1. Differential Pressure 580 psi
2. Closure time 2 seconds
3. Leak rate test 17 (psi / 10 min)
Results/Comments: Bad passing, exceed API 14B limitation

Valve Name: Wing Valve


Tag No.: WSV-02373
Operations: 1. Differential Pressure 1,010 psi
2. Closure time 41 seconds
3. Leak rate test 1 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Swap Valve


Tag No.: HV-02011
Operations: 1. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Test Header


Tag No.: XV-04460
Operations: 1. Differential Pressure 200 psi
2. Closure time 2 seconds
3. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: XV Valve to Production Header


Tag No.: XV-04461
Operations: 1. Differential Pressure 180 psi
2. Closure time 2 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Master Valve


Tag No.: SSV-02371
Operations: 1. Differential Pressure 1,010 psi
2. Closure time 44 seconds
3. Leak rate test 2 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: Manual Master Valve


Tag No.: HV-02010
Operations: 1. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SCSSV


Tag No.: SCSSV-02369
Operations: 1. Differential Pressure 520 psi
2. Closure time 2 seconds
3. Leak rate test 3 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The
SDV RISER API-14B CRITICAL FUNCTION TEST
Valve No.: DONG DO SDVs RISER
Date of Test: 16-Oct-17
Test Pre-conditions:
(if any) Within API 14B limitations, leak rate not exceed 11.8 psi/min

Valve Name: SDV-09357 on Production Riser


Tag No.:
Operations: 1. Differential Pressure 190.0 psi
2. Closure time 2.0 seconds
3. Leak rate test 3.0 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SDV-22382 on Gaslift Riser


Tag No.:
Operations: 1. Differential Pressure 580.0 psi
2. Closure time 2.0 seconds
3. Leak rate test 2.0 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Valve Name: SDV-32350 on SWI Riser


Tag No.:
Operations: 1. Differential Pressure 720 psi
2. Closure time 8 seconds
3. Leak rate test 4.0 (psi / 10 min)
Results/Comments: No passing. Within API 14B limitation

Work group perform CFT: 1 Le Van Nin


2 Nguyen Duc Thanh
3 Do Duc The