Professional Documents
Culture Documents
202096B5 SP 160-5-AA 60 Hz
H SP 160-5-AA, 3*460 V, 60Hz eta
[m] [%]
Q = 183.2 m³/h
H = 135 m
Es = 0.5412 kWh/m³
Pumped liquid = Water
Density = 998.2 kg/m³
220
200
180
160
140
120
100 100
80 80
60 60
40 40
20 20
Eta pump = 77 %
Eta pump+motor = 67.8 %
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
P NPSH
[kW] [m]
120 60
100 P1 50
P2
80 40
60 30
40 20
20 10
P1 = 99.17 kW
P2 = 87.31 kW
NPSH = 11.59 m
0 0
5700394812719
180
Technical:
Pump speed on which pump data are based: 3450 rpm 160
Actual calculated flow: 183.2 m³/h
140
Resulting head of the pump: 135 m
Stages: 5 120
Impeller reduc.: AA
Shaft seal for motor: CER/CARBON 100 100
Liquid: GN
RP6
213
20 P1 = 99.17 kW 10
P2 = 87.31 kW
Pumped liquid: Water NPSH = 11.59 m
Maximum liquid temperature: 313 K 0 0
U V W PE
M
3
202096B5 SP 160-5-AA 60 Hz
cos phi SP160-5-AA + MMS8000 92 kW 3*460 V, 60 Hz, SF = 1,15 I
eta [A]
cos phi
eta
0.8 400
0.6 300
0.4 200
0.2 100
0.0 0
0 20 40 60 80 100 120 140 160 P2 [kW]
n P1
[rpm] [kW]
n
3400 200
P1
3200 160
3000 120
2800 80
2600 40
2400 0
202096B5 SP 160-5-AA 60 Hz
RP6
213 GN
1274
3104
1830
192