Professional Documents
Culture Documents
TG 8000
TG 8000
SSAS option
First you must create a Hyperlink connection from your PC, you can create a connection
by COM port or LAN connection on your PC.
: su sysadm “Enter”
Note: after you entered your password (minimum 8 digits) every time you will log onto
the terminal to make changes you must write: su sysadm “Enter” and the password which
you have configured as indicated above.
Remember you can change the sysadm password again, when you are log in as sysadm
level: su “Enter” now you can see which level the unit is log in as:
Current user: sysadm
Please type: password sysadm “Enter”
Enter new password: ******** (87654321)
Confirm new password: ******** (87654321)
Password for user sysadm changed.
:
Now you are ready to input the Fax, Telex, email or SMS details to where the alert
message will be sent to as indicated below.
The command (set -am) “space”, then the entry code (0, 1, 2) “comma” then type (6)
“comma” and then the Mobile Number 4525414111 followed by (LES SMS CODE) and
press “enter” see example below for TELENOR LES.
: set –am 0,6,4525414111,66 (enter)
Except France Telecom they have special setting so if you like to use France Telecom use
type the following:
: set –am 0,6,SMS+4525414111,29 (enter)
Remember lock the unit to the LES you want to use for the SMS service with the
command set –m:
: set -m 4,104,204,304
: SEt -m ALL_OCEANS
2
To set up an email address you type the following:
The command (set -am) “space”, then the entry code (0, 1, 2) “comma” then type (254)
“comma” and then the email address ssasalert@tt.dk and press “enter” see example
below.
: set –am 0,254,ssasalert@tt.dk (enter)
You can add more then one address at the same line for the E-mail and Fax service,
Max 79 characters per line.
You can NOT do it for SMS service, please see below.
: set -am
Message Types:
Examples:
The second address (1) is set to receive both alert- and test messages:
3
: set –ame 1,3<Enter>
Note:
If an illegal, combination of parameters is used, following error code will appear:
:set –ame 0,2<Enter>
ERROR 121: Bad parameter(s)
: set -m ALL_OCEANS
You are able to add up to 199 characters in the free ALERT text for a SSAS unit.
Please type your text in Notepad, whit the tr long.txt command before the text as below.
Copy the text from Notepad, and past it in the mini-C when it is on sysadm level.
5
CONFIGURE COVERT/SECURITY ALERT
Please note that this command is only accessible for users with authority level
sysadm.
The cfg -c command is also used to enter SSA activation key for the TT-3026C
model.
DELETING ENTRIES
se –am (entry),255