Comprehensive range

of pipes, fittings and


Cast Iron Drainage Systems couplings for waste
water and rainwater
drainage within
buildings.
SAINT-GOBAIN

The SAINT-GOBAIN Group and Habitat strategy This innovation-driven group is continuously
designing solutions to build more comfortable,
Saint-Gobain, the world leader in the habitat
cost-efficient and sustainable construction projects
and construction markets, designs, manufactures
worldwide. The market leader in all its businesses,
and distributes building materials, providing
SAINT-GOBAIN is divided into four activities:
innovative solutions to meet growing demand in
Construction Products, Innovative Materials,
emerging economies, for energy efficiency and
Building Distribution and Packaging which are
for environmental protection.
either European or world leader.

The Pipe Division belongs to Construction Products


activity and acts in both new construction and
renovation sectors.

2
SAINT-GOBAIN PAM
Cast Iron Pipe Systems

The Pipe Activity in figures:


Turnover: 2.2 billion
More than 12000 employees
and 30 plants throughout the
world.

The Pipe Division

The Pipe Division of the SAINT-GOBAIN - a comprehensive range of municipal


Group is world leading manufacturer and castings: manhole covers, gully gratings,
export leader of ductile iron and cast iron access covers & surface boxes,
complete technical solutions. - complete pipe systems for waste water
The Pipe Division manufactures and sells: and rainwater drainage systems for
- complete pipe systems for water supply buildings.
(including valves and hydrants) and sewage
applications,

From SML to PAM-GLOBAL®

PAM-GLOBAL® S is worldwide manufactured over the last 25


synonymous of socketless, years, in France
cast-iron drainage systems. at SAINT-GOBAIN PAM
The PAM-GLOBAL® pipe factory.
systems have been

Choose PAM GLOBAL for cast iron soil and drain systems

PAM-GLOBAL
Leading brand
for cast iron drainage
pipes and fittings.

3
PAM-GLOBAL ® – Soil and Drain

PAM-GLOBAL®
Cast Iron Pipe Systems

Suitable for
every site condition
Fit for every job configuration,
PAM-GLOBAL® S = Drainage systems for buildings

PAM-GLOBAL® drainage systems PAM-GLOBAL® Couplings = Couplings to connect the pipe system elements
provide a wide modular range of
products. EPAMS® = Syphonic roof drainage system
The large number of product
references helps meeting all drainage
configurations and coping with most
installation constraints.
4
Benefits of PAM-GLOBAL ®
®
PAM-GLOBAL cast iron drainage
spigot systems specification
• The pipes are manufactured in a plant
complying with ISO 9001 quality management
and using the De Lavaud spinning process.
• The material of the system is made of cast iron
according to EN 1561.
• The tensile strength on samples is 300 MPa,
New lining for pipes for Corrosion protection of Strictly compatible fitting ring crush strength in average on DN 100 pipe
optimised properties fittings through KTL systems in the very highest
HPS 2000 cataphoresis coating quality is 450 MPa and Brinnell surface hardness is 220
(inside and outside)
HB degrees in average, which altogether indicate
greater resistance to impacts, easier machining
and cutting onsite.
• The spigot pipes and fittings, their couplings
and accessories comply with EN 877 standard
and RAL-GZ 698 special quality mark with specific
testing requirements. The rubber gaskets of the
coupling comply with EN 681-1.
• Marking: The brand logo, the reference to the
High durability far beyond
the requirements specified
High abrasion resistance
with a smooth surface for
Robust, dimension stable
and shock resistant
standard and to the quality marks, the diameter
in EN 877 excellent flow properties in DN, and the manufacturing date are marked
on the products as required in EN 877.
• The inner coating of the pipes is made of epoxy-
resin 130µm and the external coating is a primer
acrylic paint 40µm.
According to the standard requirement, the internal
coatings can withstand hot water at 95°C for 24
hours and withstand fluids between pH 2-12 for
30 days, without loosing their properties.
High acoustic Preventative fire Insensitive to heat and
• The fittings are mostly coated through a
performance, protection. PAM- cold, very low thermal cataphoresis (KTL) process.
progressive sound GLOBAL® pipes and expansion (0.0105
dampening according to fittings are mm/m K), similar to that • The drainage system belongs to the A1 Class
DIN 4109 (and VDI 4100) noncombustible in
keeping with DIN
of concrete so that their
relative movement
for Building Material according to
4102. will not cause any DIN 4102 in Germany and is non combustible.
problem.
It is CE marked on EN 877, and after tests in a
third party accredited laboratory, is ranking
“A2-s1, d0”, for the complete system.
• The thermal expansion coefficient of cast iron
is only 0.0105 mm/m.°K and similar to that of
steel and concrete; there is no need for expansion
joints.
• The noise insulation properties are complying
Primer coated in the 100% recyclable to Resources are not wasted with DIN 4109.
works, permanent eliminate all waste as 95% of the material
adhesion and attractive disposal problems used to produce PAM- • Cast iron is 100% recyclable and environment
appearance due to special
external finishing coats by
GLOBAL® S pipes consists
of scrap metal
friendly.
the works (e.g. with bridge The manufacturing plant is certified ISO 14001.
structures)

5
PAM-GLOBAL ® About Us

Located in Cologne - Germany,


SAINT-GOBAIN HES operates
within SAINT-GOBAIN
Construction Products Activity.
Part of SAINT-GOBAIN
PAM - one of the world largest
cast iron drainage systems
manufacturers -
SAINT-GOBAIN HES is the
branch in Germany for cast
iron wastewater pipe systems
which promotes and supplies
PAM-GLOBAL® cast iron pipes
to customers in Germany and
abroad.

SAINT- GOBAIN HES and SAINT-GOBAIN PAM closely work to promote the quality of the PAM cast
iron products worldwide. The teams in Germany and France are ready to support your building projects
everywhere and supply you with the relevant information.

Liability
The PAM-GLOBAL® S manual is written for general guidance only. Therefore no responsibility can be
accepted for any mistakes, omissions or incorrect assumptions. SAINT-GOBAIN HES does not accept
liability for any claims on installations where components not manufactured by SAINT-GOBAIN PAM
should be involved in a system failure.
Whilst every care has been taken to ensure that information contained in this catalogue is correct,
SAINT-GOBAIN HES or its agents do not accept responsibility for any mistakes herein. Our policy is
one of continuous improvement. We therefore reserve the right to change or alter any product
characteristics without prior notice.

Infringement of SAINT-GOBAIN HES Copyright ©


No part of this manual can be partly copied, biased or modified by any means without the written
consent of the copyright owner.

6
PAM-GLOBAL ® Systems

In the De Lavaud process the molten metal is gradually input into a steel mould rotating
at high speed. The process is characterised by its quick cooling that gives a finer
solidification matrix and a more homogeneous metallurgical structure.

Main advantages of the De Lavaud process


Heat treatment
After being spun the PAM-GLOBAL® pipes
are placed and rotated in a heat treatment
furnace at 950°C and then gradually cooled
again. This step is essential to the process
as it transforms the cast iron's metallurgical
structure. The reduction of iron carbides and
the increase of ferrite content considerably
improve the mechanical properties of cast
iron and reduce its surface hardness. The
graphite of the cast iron resulting from the
SAINT-GOBAIN PAM process forms
clustered graphite, halfway between lamellar
and ductile iron.

SEM Photo: Rosette-shaped SEM Photo: Graphite formation in


graphite formation of regular lamellar cast iron
PAM-GLOBAL® pipes

Saint Gobain PAM


The pipes process Others EN 877 requirements

Tensile Strength on samples


300 270 200 min.
in MPa (average value)
Ring Crush Strength
450 360 350 min.
in MPa (average value, DN 100 pipes)
Brinnell Surface Hardness
220 245 260 max.
in HB degree (average value)

These results indicate greater resistance to impacts and crushing, easier machining and cutting. This also
means the products are easier to install on job sites.

8
PAM-GLOBAL ® S Pipes - Coating

New epoxy-resin

1 inner coat with


optimised properties
(130 µm)

2 Cast iron
De Lavaud process

3 Outer coat
(acrylic primer 40 µm)

The coatings principle is to offer consistent performance for pipes, fittings and accessories without any weak
points. So that you can be sure of the products you specify and to fit important changes recently noticed on fluids
carried – disinfectants, hygiene products… - SAINT-GOBAIN PAM regularly makes assessments on coatings.
They are continuously upgraded to provide high protection level against corrosion, and long-lasting properties
to protect the pipe work lifespan.

The inner coating of the PAM-GLOBAL® S pipes has been designed to withstand most chemical stress and resist
abrasion. Made of an epoxy-resin regularly assessed, this coating benefits from continuous improvement to meet
waste water drainage increasing constraints. Its smooth surface enhances flow capacity and prevents incrustations
and deposits. The inner coatings of pipes and fittings have been paired for PAM-GLOBAL® S system consistency,
to withstand equivalent stress and to ensure no weak link could affect the pipe work durability.
The coatings performance of PAM-GLOBAL® S pipes and fittings exceeds by far EN 877 requirements.

PAM-GLOBAL ® S Products and couplings with EPDM gaskets


To provide clearer guidance on the
Test
chemical resistance of S range in Dilution pH 23° 50° 65° 70°
duration
domestic applications,
SALT WATER Same as sea water
SAINT-GOBAIN PAM has carried out 30g/l

20 additional tests to the EN 877 DETERGENTS 28j


Standard requirements on detergent L aundry detergents P hosphate free wash 2ml / l 7,7 28j
products and special products of Softener 2ml/ l 7,6 28j
common use. The tests were carried Dish washer detergents Washing tablet 3g/ l 9,3 28j
out on samples, under the temperature Washing gel 3g/ l 9,8 28j
of use recommended by the
Washing up liquid 2ml/ l 7,65 not applicable 28j
manufacturers and where it was
Stain remover Type “ACE GENTL E"
relevant, up to 70°C since hot water 7,7 28j

is normally supplied in dwellings around COMBINATION Wash + stain remover 2ml/l+ 3ml/ l 7,7 28j
50 - 60°C. After stopping the test, the Wash + Softener 2 ml + 3ml/ l 7,7 28j
pipes and fittings shall be washed CL EANING P RODUCTS Floor cleaning product 8ml/ l 8,2
not
applicable 28j
immediately to eliminate any stains and Bleach 8ml/ l 8,25 not applicable 28j
the coatings shall be examined with
WC CL EANERS Toilet bowl cleaner (gel) 20ml/ l 5,45 28j
regard to blistering and rusting both
Drain cleaner gel 0,33 ml/ l
according to ISO 4628-2 and 3. 13 not applicable 4j

(Accepted levels according EN 877) L iquid descaler 80ml/ l 2,07 28j

The duration of the test would potentially be equivalent to the extrapolation of a real chemical stress undergone during 7
or 10 years (a 10 to15 min stress per day). This test method however simulates a more severe stress since the samples lie
in direct contact with the solution, the temperature being maintained and the test includes no rinsing over its duration.
= Resistance
9
PAM-GLOBAL ® Fittings - Coating

Coating Process for PAM


GLOBAL® Fittings :
The common coating for
fittings is an epoxy resin
deposited through a
cataphoresis process.
However other processes,
like fluidised bed, can be
used to meet specific
requirements.

Internal - external:
Epoxy-film - brown-red colour
- deposited by cataphoresis
and thermoreticulated.

Technology:
Cataphoresis is a coating
process which deposits a film
of regular thickness on
an electrically charged
metallic surface.

This process has long been


recognized as the most
successful technology for
surface coating in the
automotive field, but it was
first used for cast components
by SAINT-GOBAIN PAM. in order to enhance the excellent adhesion and
coating's covering power. high impact resistance.
Reliability: The coating is composed of
The optimised process by pigments and an epoxy Performance:
SAINT-GOBAIN PAM is bonding in a water solution, Resistance to salt
based on a careful shot- which uniformly deposit on spray test above 1500
blasting and a specific the fittings surface.
hours.
chemical surface treatment, The deposited film shows

1 2 3 4 5 6 7 8

1 Shot blasting 3 Hot phosphate process 5 Superior cataphoresis 7 Oven drying180˚C

2 Rinsing 4 Rinsing 6 Rinsing 8 Cooling

The cast iron components are conveyed through different tanks after being shot blasted.
Cataphoresis is a fully automated painting process offering significant benefits.
10
Advanced coating method
for PAM-GLOBAL® fittings
provides flawless adhesion
and good protection of the
edges and thus a better
corrosion resistance.

Identification Marking
PAM-GLOBAL® fittings
supplied by SAINT-GOBAIN
HES GmbH are marked with
a framed label. These
embossed frames
are patented.

PAM-GLOBAL® pipes are marked PAM-GLOBAL® S DN 100. GEG marking indicates a


as shown in the above image. CE marking indicates that the superior Quality Mark for cast
“DN” attribute varies product meets basic safety iron drainage pipes and fittings.
according to the nominal requirements. A2-s1,d0 stands 01-10 stands for the week and
diameter of each pipe: e.g. for the reaction to fire ranking year the pipe was manufactured.
we chose to display.

11
PAM-GLOBAL ® – Quality Certifications

Complete and compatible


pipes, couplings, fittings and
accessories: PAM-GLOBAL®
offers a comprehensive range of
products.
Combined with coatings and
couplings the PAM-GLOBAL® range
builds consistent pipe systems
benefiting from the outstanding
robust properties of cast iron.

ISO, International Standards

ISO 9001 certification is the recognition by a third party (accredited organization)


that the quality management system of the company fully complies with the standard’s
requirements.
It is recognized in more than 70 countries. It covers such company activities
as quality control, R&D, production technologies, company organization and customer
service.

ISO 14001:2004 Environmental Management System.


The certificate of compliance proves that the company has a global approach to minimize
the impact made to the environment throughout manufacturing process: Gwuidelines for
improvement, action plans and better follow-up procedures.
®
PAM-GLOBAL cast iron elements are made from 95% of metal scrap and are 100% recyclable;
thus, the impact on environment is really minimized.

EN 877 Standard

The European standard EN 877 “Cast iron pipes and fittings, their joints and accessories for
the evacuation of water from buildings” , known to be the most demanding standard worldwide,
sets up technical specifications as well as test methods and quality control.

This leads to:


• Mechanical performances
• Respect of dimensions
• Special requirements on couplings
• Efficient traceability of production sites.

12
Voluntary Quality Mark GEG RAL-GZ 698

Being self declared, EN 877 is only proved when third party validated on all criteria and
periodically tested.
Recognised quality mark, GEG (Gütezeichen Entwasserungstechnik Guss) has set forth a
list of testing criteria and quality requirements far exceeding those included in EN 877.
Meeting all these requirements is the first and foremost condition to obtain a RAL-GEG
marking. Third-party inspections are carried out by MPA-NRW twice a year.

Quality marks are voluntary. Their scope is aiming at fitness for purpose and at valuing the
CE Marking
product in a customer-supplier relationship.
Unlike Quality Marks, CE marking is mandatory to be allowed pass into the European Union
and between member states.
Made compulsory by the European Directive for Construction product, its scope is limited to
health and operational safety. CE marking is a minimum precondition to guarantee that
construction products are not dangerous for the European consumers and users. It sets the
same safety criteria shared all over Europe and is mainly intended for the authorities in charge
of market control.
Reaction to fire alone was retained as safety criterion for drainage systems (see Fire protection
chapter).
Based on EN 877, CE marking became mandatory on cast iron drainage products leaving
the factory, from 2009 September the 1st.
For Construction Products, reaction to fire is assessed on the basis of standardised tests and
described in a EUROCLASS classification. For complete ranges – pipes, fittings, couplings
and accessories SAINT-GOBAIN PAM has obtained the excellent EUROCLASS ranking:
A2, s1-d0, now mentioned on the products.
EUROCLASS being based on test methods and a classification harmonised throughout Europe,
the scoring can be used to compare materials and product performances you specify.

Compliance with standards

European Standard International Standard


Cast iron pipes and fittings, their joints and accessories for the evacuation
of water from buildings. EN 877
Requirements, test methods and quality assurance

Cast iron drainage pipes and fittings (spigot) ISO 6594


Elastomeric seals - Material requirements EN 681-1 ISO 4633
Requirements for a quality management system design, product development, ISO 9001
production, installation and after sales support
Environmental management system
ISO 14001
Requirements with guidance for use
Testing standards
Fire tests
Fire classification of construction products and building elements. EN 13501
Classification using data from reaction to fire tests
Reaction to fire tests for building products - Part 1. Building products
excluding floorings exposed to the thermal attack by a single burning item EN 13823

Measurement of noise
Laboratory measurement of noise from waste EN 14366
water installations

13
Fire Protection

System Characteristics

PAM-GLOBAL® cast iron pipe


systems are flame proof ,
and have outstanding
properties not to spread the
fire. This is confirmed by tests
carried out both domestically
and abroad
(C.T.I.C.M./IBMB).
Test certificate No.:
P-3725/4130-MPA BS.
For high fire proofing
requirements in the structural
engineering sector,
specifying PAM-GLOBAL®
pipe systems is the
reasonable choice.

Comparison: 1 kg of consisting of carbon


The most important Material Classification
polyethylene (PE) produces monoxide, carbon dioxide
benefits of a fire load of 12 KWh. 1 kg and soot.*
PAM-GLOBAL ® PAM-GLOBAL® pipes and
fittings are made of cast iron of heating oil has a gross
cast iron pipe calorific value of 11.7 KWh.* Thermal Expansion
with lamellar graphite
systems according to DIN EN 1561.
This material conforms to the Smoke Development The thermal expansion
Class A1 Building Material coefficient of cast iron is only
according to DIN 4102 in In the event of a fire, the 0.0105 mm/m.°K.
Germany and is non PAM-GLOBAL® pipe system Under a temperature change
combustible. remains sealed; smoke that of 50 K, the expansion of a
could develop inside the DN 100 pipe of 10 m length
Fire Load pipes is dissipated via the is only 5.3 mm. This
rooftop main ventilation. expansion is absorbed by
Cast iron pipes and fittings Comparison: 10 kg of the couplings.
are considered non polyethylene (PE) or
combustible. polypropylene (PP) produces * Source: Bernd Prümer
Their fire loads do not need approximately 23,000 m3 of “ Brandschutz in der
to be taken into account. highly toxic smoke, Haustechnik” Gentner Verlag.
The “Fire load” of a product
is defined as follows: it is the
quantity of energy released
during combustion. It highly
depends on the type and
quantity of flammable
materials used for the product
manufacturing.
Formerly, a fire load of 7
KWh/m was authorised in
emergency corridors.

This regulation is no longer


applicable due to the general
Pipe Systems Guidelines,
whereby fire loads are no
more permitted on
emergency corridors or
emergency exits.
14
Fire Protection

Cast iron as a material itself is classified as A1


in the Euroclass classification for reaction to fire.
In tests carried out by the CSTB accredited
laboratory, SAINT-GOBAIN PAM cast iron ranges
(pipes, fittings and accessories including elastomer
gaskets and coatings) received the following
excellent Euroclass ranking: A2 -s1, d0.
For smoke emission and the production of flaming
droplets, the SAINT-GOBAIN PAM products
respectively achieved the highest possible rating:
s1 and d0.
So, cast iron remains one of the safest drainage
material for fire safety.

Fire resistance is a construction component's


ability to withstand fire for a given period of time
and to retain its serviceability in the event of fire.

For fire safety in a building, the major responsibility SAINT-GOBAIN PAM cast iron has a melting point
rests with the project manager who must respect over 1000°C. In most cases it requires no
the regulation in force. In buildings at risk, such additional fire protection. SAINT-GOBAIN PAM
as multi-storey buildings, materials with reduced has carried out a non exhaustive series of tests
flammability should be selected to apply on its cast iron pipe systems in order to make
precautionary principle. precise recommendations for fire resistance
Reaction to fire is the instant behaviour when a requirements up to 240 minutes (4 hours).
fire breaks out, its propensity to ignite or feed a
fire. For drainage systems to obtain CE marking, SAINT-GOBAIN PAM cast iron pipes are
“Reaction to fire” requires a mandatory certificate, non combustible, they do not feed the fire, nor
stipulating their EUROCLASS classification, issued give off either gases or smokes liable to delay fire
by an accredited and independent laboratory. fighters or damage other equipment.

Examples of tested downpipes penetrating slabs solutions with PAM-GLOBAL® S system


DN 50 to DN 150

(Cert. No: P-MPA-E-07-028)

E.g. in production plants,


• Slab penetration shall For acoustic requirements parking lots, warehouses,
be limited to the beware that if cement regardless of noise
technically required size. only is used, the sealing insulation
• Slab sealing for open can cause sound bridges.
hoppers shall be made of • According to MLAR,
non combustible shafts used for insulation concrete
materials, e.g. cement or sound insulation, in For combustible pipes filling
mortar, concrete or the vicinity of the ducts (HDPE, PVC, PP etc.)
mineral wool. surface or walls with fire larger than DN 32, fire
If mineral wool is used, it break requirements, shall spreading measurements
must have, in accordance also be made of mineral and test results are an
with MLAR, a melting casings of the above absolute requirement, so
point ≥ 1000° C and a mentioned quality. that the fire regulation
concrete
filling
relative density of at least can be applied.
90 kg/m3.

15
Noise Insulation

What Exactly is Plumbing Noise?

Waste water and rainwater drainage generates airborne and structure-


borne noise between rooms, which usually result from a mixed flow, when
the pipe is filled with water and air.
Under such circumstances a pipe will radiate noise outwards to any
lightweight ceilings, cupboards and similar areas wherever it makes contact.

Airborne noise (A)


When a material is dense and thick, the
pipe walls prevent air transmission;
as is the case with cast iron which offers
intrinsic acoustic properties.

Structure-borne noise (B)


When the noise produced within a pipe
is not transmitted by the air, the
residual noise is transmitted by
structural vibrations. Whilst the
mass of the cast iron limits the
vibratory level, the junctions and
fixing to the building will propagate
noise. Objective: Dampen the
vibrations at the connections with
the solid structure.

PAM-GLOBAL® Acoustic Dampener


The acoustic dampener is designed to reduce structure-borne
noise propagating through connections between the pipe system
and the building. This accessory, made of a stainless steel casing
surrounding an elastomer shock absorber, is fitted between the
back of the bracket and the structure (wall, ceiling, etc...). It can
be used on any cast iron pipe bracket from DN 50 to DN 150,
installed horizontally or vertically. With PAM-GLOBAL® dampener,
such low values as 5 dB(A) in a 2 l/s flow rate can be achieved
independent of how tight the bracket is screwed.

02 - 07
DIN 50 - 150
(Date of Manufacture)

DN Weight Product Code


50 - 150 0,11 205113

Airplane Noise Music Traffic Clock Snowfall

16
Noise Insulation

Requirements defined
by DIN 4109 and VDI
Drainage installations must within the same dwelling.
be designed in accordance As a result of its endorsement
with DIN 4109/A1. This by the building authorities
standard defines the DIN 4109/A1 is now made
expected requirements for compulsory under public law.
noise control with the aim of
protecting people in However, it only sets a
residential rooms from minimum requirement.
unreasonable nuisance The VDI Guidelines 4100
caused by sound define 3 sound insulation
transmission. levels (SSt).
These 3 levels can cover all
DIN 4109-1989 specifies sound insulation requirements
the expected requirements and they are to be promoted
regarding the maximum between all actors involved
noise level for in building projects including
rooms requiring noise further occupants on the basis
insulation. These include of private law.
living rooms, bedrooms, To avoid subsequent disputes
workrooms and classrooms. it is highly recommended that
the sound insulation level
Such requirements do not requirements (SSt) should be
apply to room partitions stipulated in the contracts.

Test results for the PAM-GLOBAL® pipe systems

35 dB(A) 30 dB(A) 26 dB(A) 19 dB(A) 5 dB(A)


standard for standard for living PAM-GLOBAL® pipe PAM-GLOBAL® pipe PAM-GLOBAL® pipe
kitchen and room and bedroom with standard bracket with rubber lined with acoustic dampener
bathroom noise is divided bracket noise is noise is divided
divided
by 2,5 by 25
by 5

EN 14366 complying test results obtained for a flow rate of 2 l/s and a wall thickness of 250±50 kg/m2 (IBP laboratory)

17
Environmental Awareness

PAM-GLOBAL® cast iron pipe


100% recyclable systems are made of
indefinitely without recycled scrap metals and so
losing any of its save natural resources. Unlike
properties. plastics, it can be completely
and systematically recycled
at the end of its life through
processes that are not harmful
to the environment.
As the world leader in
construction products,
SAINT-GOBAIN aims at
providing innovative solutions
to take up the challenges for
the future posed by
environment protection and
energy savings. All the
products of the Group are
designed with a view to
making full allowance for
environmental issues and
enhancing the energy
efficiency of buildings.

PAM-GLOBAL® cast iron pipe systems are based on the principle of


modular ranges of removable components. Their mechanical assemblies
are reversible. You can change your mind today or even tomorrow.
When pipe systems are disassembled or modified, these components
can be reused, which cuts down waste dumping.

PAM-GLOBAL® pipe systems can be recycled without any deterioration


The Right Choice of their properties, so they can be reused for exactly the same purpose.
For Green Buildings In other words, a pipe can be recycled as pipe.

Owing to the stability of their mechanical properties, it is currently


admitted that the service life of PAM-GLOBAL® pipe systems is twice
that of alternative products made of plastic materials.

For its recycled content, its actual recycling and long lasting properties,
PAM-GLOBAL® cast iron can be considered environment friendly.
18
PAM-GLOBAL ® S - Products

PAM-GLOBAL® S Pipes and Fittings (DIN EN 877 and DIN 19522)

Pipe Coupling Fitting

Nominal Coupling Weight


Exterior-Ø Wall Thickness Surface
Diameter distance (approx.)

Tolerance of pipes empty full approximate m2


and fittings
DN DE Tolerance e t kg/m kg/m per meter
50 58 3,5 -0,5 30 4,2 4,3 0,18
70 78 +2 3,5 -0,5 35 5,9 9,9 0,25
80 83 -1 3,5 -0,5 35 6,1 10,6 0,26
100 110 3,5 -0,5 40 8,1 16,4 0,35
125 135 +2 4,0 -0,5 45 11,4 24,1 0,42
150 160 -2 4,0 -0,5 50 13,6 31,7 0,50
200 210 5,0 -1,0 60 22,5 53,9 0,65
+2,5
250 274 5,5 -1,0 70 32,4 86,7 0,85
-2,5
300 326 6,0 -1,0 80 42,3 119,7 1,02

On request for DN 400, 500 and 600.

PAM-GLOBAL® S Pipes
L = 3000 mm
DN weight Product Code
50 12,50 156361
70 17,00 156454
80 18,20 156550
100 24,30 156561
125 34,30 156734
150 40,90 156825
200 67,40 156949
250 97,30 157048
300 126,80 157113

All dimensions are in mm and nominal weights in kg.

19
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S - Fittings
PAM-GLOBAL ® S - 88˚ Bend
DN X Weight Product Code
50 75 0,72 155749
70 90 1,24 155778
80 95 1,30 176706
100 110 2,00 155813
125 125 3,20 155867
150 145 4,10 155900
200 180 7,80 155930

PAM-GLOBAL ® S - 68˚ Bend


DN X Weight Product Code
50 65 0,72 155750
70 75 1,20 155779
80 80 1,05 176705
100 90 1,75 155814
125 105 2,90 155868
150 120 4,10 155901
200 145 7,10 156968

PAM-GLOBAL ® S - 45˚ Bend DN X Weight Product Code


50 50 0,56 155751
70 60 0,90 155780
80 60 0,79 176704
100 70 1,40 155815
125 80 2,25 155869
150 90 3,00 155902
200 110 5,30 155931
250 130 9,50 155947
300 155 15,90 155959

PAM-GLOBAL ® S - 30˚ Bend DN X Weight Product Code


50 45 0,47 155753
70 50 0,92 155782
80 50 0,79 176703
100 60 1,40 155817
125 70 2,00 155871
150 80 3,00 155904
200 95 5,10 155933
250 110 9,50 155948
300 130 13,80 155960

PAM-GLOBAL ® S - 15˚ Bend DN X Weight Product Code


50 40 0,47 155752
70 45 0,63 155781
80 45 0,68 176702
100 50 1,15 155816
125 60 1,77 155870
150 65 2,40 155903
200 80 4,35 155932

20
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S - 88˚ Bend (long tail)


DN X1 X2 K Weight Product Code
70 250 90 160 2,80 155785
80 250 95 160 2,90 179681
100 250 110 140 3,60 155823

PAM-GLOBAL ® S - 45˚ Bend (long tail)


DN X1 X2 K Weight Product Code
70 250 60 190 2,60 155786
80 250 60 190 2,70 179680
100 250 70 180 4,20 155824

PAM-GLOBAL ® S - 88˚ Double Bend

DN X1 X2 x3 Weight Product Code


50 50 100 121 1,00 155754
70 60 120 145 1,70 155783
80 60 120 145 1,50 176707
100 70 140 170 3,10 155819
125 80 160 195 4,20 155872
150 90 180 219 7,00 155905

PAM-GLOBAL ® S - 88˚ Double Bend (long tail)


(For connecting downpipes with
horizontal lines, DIN 1986-100)
DN X1 X2 x3 Weight Product Code
70 60 301 273 3,20 155784
80 60 301 273 3,20 179679
100 70 312 291 4,80 155820
125 80 322 308 6,10 155873
150 90 334 326 9,60 155906

PAM-GLOBAL ® S Offset PAM-GLOBAL ® S Offset (A) = 65mm


DN X L Weight Product Code
100 70 205 2,00 155812

PAM-GLOBAL ® S Offset (A) = 130mm


DN X L Weight Product Code
100 70 270 3,76 155821

PAM-GLOBAL ® S Offset (A) = 200mm


DN X L Weight Product Code
100 70 340 4,50 155822

21
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S - 45˚ Branch


DN X1 X2 X3 L Weight Product Code
50x50 50 135 135 185 1,35 155769
70x50 40 150 150 190 1,87 155789
80x50 45 135 135 180 1,60 173786
70x70 55 160 160 215 2,10 155806
80x80 60 155 155 215 2,20 173787
100x50 35 165 165 200 2,40 155828
100x70 50 185 185 235 2,80 155831
100x80 50 185 185 235 3,18 173788
100x100 70 205 205 275 3,80 155857
125x50 20 185 185 205 3,24 155877
125x70 40 200 200 240 4,30 155879
125x80 51 189 189 240 4,20 176716
125x100 60 220 220 280 5,60 155882
125x125 80 240 240 320 5,70 155895
150x70 30 215 215 245 5,10 155910
150x80 50 220 220 255 5,30 176733
150x100 55 240 240 295 6,12 155912
150x125 70 255 255 325 7,00 155914
150x150 90 265 265 355 8,75 155926
200x70 15 240 240 255 7,00 155934
200x80 20 240 240 260 7,34 176734
200x100 40 280 270 310 9,33 155935
200x125 55 295 285 340 10,69 155936
200x150 75 315 300 375 12,32 155937
200x200 115 340 340 455 16,78 155944
250x100 15 310 310 325 15,40 155949
250x125 35 335 335 370 16,00 155950
250x150 55 350 350 405 17,25 155951
250x200 90 385 385 475 22,40 155952
250x250 130 430 430 560 29,00 155956
300x100 5 345 345 350 19,30 155961
300x125 15 360 360 375 21,00 155962
300x150 35 380 380 415 28,00 155963
300x200 70 440 415 485 28,10 155964
300x250 115 465 465 580 37,60 155965
300x300 155 505 505 660 46,30 155968

PAM-GLOBAL ® S - 135˚ Bend

DN X K L Weight Product Code


100 312 100 150 5,00 155818

K= Maximum zone of possible cut

22
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S - 88˚ Branch


DN X1 X2 X3 L Weight Product Code
50x50 79 80 66 145 1,00 155767
70x50 83 90 72 155 1,33 155787
80x50 85 90 75 160 1,40 176718
70x70 97 95 83 180 1,70 155804
80x80 95 95 85 180 1,80 176719
100x50 94 105 76 170 2,05 155827
100x70 102 110 88 190 2,46 155829
100x80 100 110 90 190 2,44 176720
100x100 115 115 105 220 2,65 155855
125x50 98 120 82 180 2,80 155876
125x70 107 125 93 200 3,20 155878
125x80 105 125 100 205 2,90 176722
125x100 125 130 110 235 4,20 155880
125x125 137 135 123 260 5,00 155894
150x50 100 140 100 200 3,90 155908
150x70 115 140 100 215 4,70 155909
150x80 115 140 105 220 4,36 176723
150x100 130 145 115 245 5,50 155911
150x125 147 150 128 275 6,10 155913
150x150 158 155 142 300 5,75 155925
200x100 145 175 125 270 8,80 156980
200x200 10,40 157024

PAM-GLOBAL ® S - 88˚ Double Branch


DN X1 X2 X3 X4 X5 L Weight Product Code
100x50x50 94 94 105 76 76 180 2,20 155825
100x70x70 102 102 110 88 88 190 2,70 155826
100x80x80 100 100 110 90 90 190 2,70 179685
100x100x100 115 115 120 105 105 230 3,70 155858
125x100x100 130 130 135 115 115 245 5,00 155874
150x100x100 130 130 145 115 115 245 7,10 155907

PAM-GLOBAL ® S - 70˚ Branch


DN X1 X2 X3 L Weight Product Code
50x50 55 80 80 135 1,00 155768
70x50 55 90 90 145 1,30 155788
70x70 70 100 100 170 1,70 155805
100x100 85 130 130 215 2,75 155856
125x100 85 145 140 225 3,93 155881

PAM-GLOBAL ® S - 45˚ Double Branch


DN X1 X2 X3 L Weight Product Code
100x100 70 190 190 260 4,60 156709
125x125 75 230 230 305 7,50 156817
X2

150x150 90 270 270 360 12,00 156936


L
X3
X1

23
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S 88˚ Corner Branch

DN X1 X2 X3 L Weight Product Code


80x80x80 95 95 85 180 2,00 179682
100x70x70 102 110 88 190 2,70 155839
100x80x80 100 110 90 190 2,75 179683
100x100x100 115 120 105 220 3,43 155860
125x70x70 107 125 93 200 3,70 155888
125x100x100 125 130 110 235 5,00 155889
150x100x100 130 145 115 245 7,10 155919

PAM-GLOBAL ® S 88˚ Corner Branch (long tail)


with 90° Corner Angle
DN X1 X2 X3 L K Weight Product Code
100x100x100 325 115 105 430 210 5,20 155862

Particulary suitable for slab penetration.

PAM-GLOBAL ® S 88˚ Branch (long tail)


DN X1 X2 X3 L K Weight Product Code
100x100 325 115 105 430 210 4,60 155861

Particulary suitable for slab penetration.

24
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® Combination Branch

DN H Weight Product Code


100 x 70 x 100 230 4,50 171524
100 x 80 x 100 230 4,27 176658
100 x 100 x 100 230 4,30 175605

The combination branch downpipes in shafts,


enables simultaneous adjacent sanitary blocks
connection of multiple and generally wherever
plumbing elements. Due the space for wastewater
to its specific shape, it connections is limited.
can be used to connect

PAM-GLOBAL ® S Typical Applications For Combination Branches

Sink Sink

WC WC

Tub
Finished Floor

The combination branch bathtub), at the same floor level. combination branch to be
enables connection of WC and The 45° angle of outlets is installed in a 180° rotated
another plumbing element (e.g. double-sided to allow the position.

PAM-GLOBAL ® S Special Used in the simultaneous The remaining 2 outlets


Fittings connection of multiple with an internal diameter
plumbing elements (main of 59 cm are for push-fit
pipe and WC outlet DN connectors.
100).
Special Fittings Weight Product Code Special Fittings Weight Product Code
Left 5,80 155848 Right 6,00 155847

25
PAM-GLOBAL ® S - Products

PAM-GLOBAL® S Taper DN A L t2 t1 Weight Product Code


70 x 50 10 75 35 30 0,64 155763
80 x 50 13 80 35 30 0,70 176727
100 x 50 25 80 40 30 0,80 155764
100 x 70 16 85 40 35 1,05 155801
100 x 80 14 90 40 35 0,95 176728
125 x 50 38,5 85 45 30 1,50 155765
125 x 70 28,5 90 45 35 1,40 155802
125 x 80 26 95 45 35 1,30 176730
125 x 100 12,5 95 45 40 1,60 155842
150 x 50 51 95 50 30 1,90 155766
150 x 70 41 100 50 35 1,80 155803
150 x 80 39 100 80 35 2,00 176732
150 x 100 25 105 50 40 1,95 155843
150 x 125 12,5 110 50 45 2,00 155892
200 x 100 50 115 60 40 3,60 155844
200 x 125 37,5 120 60 45 3,80 155893
200 x 150 25 125 60 50 3,40 155922
250 x 150 57 140 70 50 6,30 155923
250 x 200 32 145 70 60 10,70 155942
300 x 150 83 150 80 50 10,70 155924
300 x 200 58 160 80 60 10,20 155943
300 x 250 26 170 80 70 10,70 155955

PAM-GLOBAL ® S Stack
Support Pipe
DN D L Weight Product Code
50 87 220 1,30 156372
70 106 220 1,60 155773
80 118 220 1,80 156462
100 145 220 2,40 156577
125 170 220 3,20 156745
150 195 220 4,10 156837
200 245 220 5,90 156959
250 340 300 12,35 157058
300 390 300 17,80 157123

PAM-GLOBAL ® S Stack Support Bracket


DN D1 D2 A B C kg. Nr.
50 150 108 195 33 17 0,80 179217
70 170 112 215 30 19 1,10 179218
80 175 133 218 33 20 1,20 176713
100 214 162 259 33 20 1,30 179219
125 228 187 275 33 20 1,50 179220
150 255 222 300 33 22 2,00 179221
200 310 278 362 36 22 2,30 179222
250 394 354 444 40 25 5,60 179223
300 448 406 398 40 30 7,40 179224

26
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S Short Pipe With Access Door, Round Opening


For Connecting, Vertical and Horizontal pipe works
DN H d1 d2 L Weight Product Code
50 59 53 105 190 2,30 179191
70 69 73 125 210 3,00 155799
80 71 73 125 210 3,20 179647
100 84 104 159 260 5,00 179192

EPDM O-Ring gasket


Hardness: 45 Shore A

PAM-GLOBAL ® S Short Pipe With Access Door, Rectangular Opening


For Ground, Vertical and Horizontal pipe works
DN H G d A F L Weight Product Code
100 83 160 100 200 230 340 7,60 179196
125 101 190 125 225 255 370 10,30 179197
150 112 215 150 250 280 395 14,50 179198
200 137 262 200 300 330 485 22,00 179199
250 170 330 260 350 380 570 38,50 179200
300 195 380 310 400 430 640 50,00 179201

Supplied with EPDM sealing Supplied with 6 screws and


system in DN 100-200 EPDM sealing system in
Hardness: 45 Shore A DN 250-300

PAM-GLOBAL ® S Short pipe with Access Door Round, Twist-on Opening


For Vertical and Horizontal pipe works
DN H d1 d2 L Weight Product Code
50 73 75 108 160 1,96 156414
80 89 101 134 205 3,15 156513
100 102 128 160 250 4,50 156659
125 125 154 189 280 6,48 156794
150 142 181 224 320 10,38 156905
200 165 181 224 360 14,00 157015
250 196 181 225 380 19,70 157098
300 222 181 227 400 26,30 157161

1 2 3 4

1- Operation safety: 2- Convenience: 3-4 The cast iron plug and the
Possible bleeding before Ease of opening and closing internal sealing can be removed
opening in case of the cast iron plug with separately.
accidental overpressure. standard tools or a T-handle
operating wrench

27
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S Blank End


DN L Weight Product Number
50 30 0,25 155747
70 35 0,40 155776
80 35 0,45 176700
100 40 0,80 155809
125 45 1,20 155865
150 50 1,70 155898
200 60 3,20 155928
250 70 5,90 155945
300 80 10,00 155957

PAM-GLOBAL ® S Blank End With Clamp


DN a1) Weight Product Number
100 90 2,50 179234
125 90 3,50 179235
150 95 4,50 179236
200 95 6,00 179237

Clamp material: St 37. The clamp consists of a1) Min. length top edge
Supplied with galvanized 3 parts in sizes DN of nut
EPDM sealing. 150 and DN 200.

PAM-GLOBAL ® S Expansion Plug


DN DE L Weight Product Number
50 62 25 0,34 156374
70 85 45 0,66 156468
80 90 45 0,7 156464
L 100 118 57 1,25 156579
125 143 55 1,7 156747
150 168 53 2,4 156839
200 220 54 5,2 156961

For DN 250 and 300 expansion plugs are now replaced with blank ends

28
PAM-GLOBAL ® S - Products

PAM-GLOBAL ® S Stench Trap

DN I h X1 X2 X3 X4 w Weight Product Number


50 190 250 182 68 122 68 60 2,90 156420
70 265 293 200 93 172 93 60 5,48 156521
80 265 293 200 93 172 93 60 5,85 176714
100 325 392 282 110 215 110 100 9,50 156668
125 390 446 316 130 260 130 100 14,35 156801
150 470 493 348 145 325 145 100 21,75 156912
200 600 600 420 180 400 200 100 38,38 157018
®
PAM-GLOBAL S branch the adequate depth of vertical pipe works if
traps are preferably used water seal but are suitable combined with bends.
on rainwater systems. for horizontal and/or Arrows stamped on the
Branch traps must be vertical pipework route. body indicate flow
Cleaning access on the bottom from installed vertically to keep They can be installed on direction.
DN 50 to 150.

WC Connector

DN L K Weight Product Number


100 225 170 2,90 155845

90˚ Bend WC Connector

DN X1 X2 X3 X4 Weight Product Number


80 145 55 50 105 2,00 176725
100 150 44 40 84 3,00 155852

90˚ Double Bend WC Connector


Only Fit For Vertical Assembly

DN X1 X2 A K Weight Product Number


100 225 85 250 50 5,70 155853

29
PAM-GLOBAL ® S - Products

Connecting PAM-GLOBAL ® S Pipes to the Sewer System

Connecting PAM-GLOBAL ®
Pipes to Clay Pipe With Socket Type “L” acc. to DIN EN295
DN 100 - 200

PAM-GLOBAL ® pipe Stepping ring


DN Product Code
100 179686
125 179687
Stepping ring in
compliance with EN 295 150 179688
200 179689

“L” socket

PAM-GLOBAL ® Pipe to PVC Sewage Pipe

Rollfix KGUG-Adaptor
PAM-GLOBAL ® pipe DN Code Code
100 180983 179801
125 180984 179802
150 180985 179803
200 180986 179804
Rollfix connector

l
KGUG cast iron adaptor
Size chart for KGUG cast iron adaptor
DN D d l
d mm mm mm
100 124 110 60
KG sewage pipe in compliance 125 151 125 65
with DIN 19534 150 176 160 70
200 226 200 80

Connections to other materials

Connecting cast iron pipe systems to other


materials may be required in new
construction projects or to ease renovation.
Their external diameters may differ and
solutions exist for compensation.
Please check the page 35 and contact our
Technical Support for solutions available
and dimension tables per material.

30
PAM-GLOBAL ® Couplings

PAM-GLOBAL ® RAPID NG Coupling


DN 50 - DN 300

DN D≈ H≈ L≈ Weight Code
Max. dimensions after installation S
50 70 80 42 0,10 210424
70 85 98 42 0,12 210425
80 90 103 42 0,12 210426
100 125 139 48 0,18 210427
125 147 161 56 0,28 210428
150 172 187 56 0,32 210429
200 223 240 70 0,40 210430
DN 250 and DN 300 on request.

Standard version W2 technical The PAM-GLOBAL® RAPID NG Its profile, with edges directed
specifications: coupling, single bolt, allows fast and towards the pipe, encases the
• Strap, clamps: reliable installation. SAINT-GOBAIN elastomer gasket and prevents any
1.4510/11 (AISI 430Ti / 439) PAM’s new design ensures optimized risk of it being expelled during
• Screw: coated steel class 8.8 water-tightness and pressure tightening. In case of fire, the rubber
• Nut: coated steel class 8 resistance and better than ever gasket is not exposed to flames.
corrosion resistance. When fully tightened, the coupling
ensures a built-in electrical continuity,
A wide stainless steel collar allows without any added clip.
tolerance during installation.

DN D≈ H≈ L≈ Weight Code
Max. dimensions after installation INOX
50 70 80 42 0,10 185635
70 85 98 42 0,12 207818
80 90 103 42 0,12 207819
100 125 139 48 0,18 185636
125 147 161 56 0,28 207820
150 172 187 56 0,32 207831
All stainless steel version W5 200 223 240 70 0,40 185637
technical specifications: DN 250 and DN 300 on request. Recommended for pipe systems exposed to climatic
• Strap, clamps: stresses, i.e rainwater spigot systems, drainage systems for bridges, or open multi-storey
1.4404/1.4571 car parks.
(AISI 316 L/361Ti)
• Screw and nut: austenitic
stainless steel A4-70 on AISI 316

Specific offer for a complete Nitrile coupling.


For waste water liable to contain hot oil, solvents or hydrocarbons, it is recommended
to use couplings equipped with specific NBR gaskets.
The PAM Rapid NG is designed
for a full tightening “null gap”, From now on, to meet these special requirements the PAM Rapid NG all stainless
there is no need for checking steel W5 coupling alone will be delivered with NBR gasket.
the torque. Please ask the complete product codes for couplings with NBR gasket.

31
PAM-GLOBAL ® Couplings

PAM-GLOBAL ® CV - CE NG Couplings
DN 50 - DN 300

DN A B D≈ L Weight Code
Max. dimensions after installation CV
50 14 22,5 70 45 0,10 210398
70 14 22,5 90 48 0,12 210400
80 14 22,5 95 48 0,15 210413
100 18 25,5 122 54 0,20 210416
125 18 25,5 147 54 0,30 210417
150 18 25,5 172 54 0,35 210418
200 18 38 222 78 0,70 210420
250 18 38 287 78 0,85 210422
300 18 38 339 78 0,90 210423
Standard version technical
specifications: These two bolts basic couplings are The PAM design ensures better than
• Collar: Ferritic Stainless Steel - mostly appreciated because simple ever water tightness and pressure
1.4510/11 or AISI 430Ti/439 and easy to remove and reinstall resistance and noticeably improves
• Plates: Ferritic Stainless Steel - without damage. corrosion resistance for these couplings.
1.4373 or 1.4510/11 or AISI
202 or AISI 430Ti/439
• Screws: Coated Stell class 8.8
(minimum of 350 h/salt spray test)

Tightening torques:
CV Couplings : 8-10 N•m for all DN
CE Couplings : 5-8 N•m for DN 50-75/80
10-12 N•m for DN 100-125
12-15 N•m for DN 150-300

All stainless steel version technical DN A B D≈ L Weight Code


specifications: Max. dimensions after installation CE
• Identifying feature: W4 0,10
50 14 22,5 70 45 185627
• Collar: Austenitic Stainless Steel
70 14 22,5 90 48 0,12 207811
1.4301 or AISI 304
• Plates: Stainless Steel A2-70 or 80 14 22,5 95 48 0,15 207813
1.4301 or AISI 304 100 18 25,5 122 54 0,20 185628
• Screws: Stainless Steel A2-70 with 125 18 25,5 147 54 0,30 207814
coating to avoid seizing 0,35
150 18 25,5 172 54 207815
200 18 38 222 78 0,70 207816
250 18 38 287 78 0,85 207817
300 18 38 339 78 0,90 185629

32
PAM-GLOBAL ® Couplings

PAM-GLOBAL ® GRIP HP COUPLINGS


Two Different Grades For A2 type For A4 type
S INOX Pressure Torque Pressure Torque
DN A2 type A4 type A mm B mm D mm E2 mm ≈Weight Resistance Nm Resistance Nm
100 227336 227344 94 45 133 15 1,3 10 20 10 20
125 227337 227345 95 45 158 15 1,9 10 20 10 20
150 227338 227346 95 45 183 15 2,1 10 30 10 30
200 227339 227347 141 60 251 35 5,3 10 50 10 30
250 227340 227348 141 60 305 35 8,7 10 65 10 50
300 227351 227349 141 60 356 35 9,9 10 80 10 80
400 227352 227350 141 60 438 35 11,7 6 80 10 90
500 227353 227361 142 60 557 35 12,8 3 80 6 90
600 227354 227362 144 60 660 35 14,1 2 120 4 80

A2 Type: A4 Type:
Casing : 1.4307 Casing : 1.4404
Screws : 1.4301 Screws : 1.4401
Barrels : 1.4307 Barrels : 1.4404
Strengthening plates : 1.4307 Strengthening plates : 1.4404
Grips : 1.4310 Grips : 1.4310

Sealing gasket : EPDM and NBR on request

PAM-GLOBAL ® FLEX HP COUPLINGS


Two Different Grades For A2 type For A4 type
S INOX Pressure Torque Pressure Torque
DN A2 type A4 type A mm B mm D mm E2 mm ≈Weight Resistance Nm Resistance Nm
100 228257 228623 94 45 129 15 1,4 10 10 10 10
125 228258 228624 94 45 152 15 1,5 10 10 10 10
150 228259 228625 94 45 180 15 1,7 10 10 10 10
200 228260 228626 139 86 229 35 3,8 10 20 10 20
250 228271 228627 139 86 294 35 4,3 10 25 10 25
300 228272 228628 139 86 346 35 4,7 10 25 10 25
400 226261 228629 139 86 449 35 7,1 6 25 10 25
500 226262 228630 139 86 551 35 6,7 3 30 6 30
600 228273 228631 139 86 653 35 7,6 2 35 4 35

A2 Type: A4 Type:
Casing : 1.4307 Casing : 1.4404
Screws : 1.4301 Screws : 1.4401
Barrels : 1.4307 Barrels : 1.4404
Strengthening plates : 1.4307 Strengthening plates : 1.4404

Sealing gasket : EPDM and NBR on request

33
PAM-GLOBAL ® Connectors

PAM-GLOBAL ® UNIGRIP Collars


DN 50 - DN300

DN P D L Max. Pressure Weight Screw Product


[mm] [mm] [mm] [bar] [mm] Code

50 22 88 76 10 0,45 M8 221261
70 22 110 79 10 0,54 M8 221267
80 25 105 78 10 0,53 M8 221268
100 33 145 93 10 0,90 M8 220750
125 32 165 93 10 0,99 M8 221269
150 32 196 102 5 1,23 M8 221270
200 32 252 118 5 1,72 M 10 221271
*DN 250 and DN 300 on request.

The grip collar is an added The requirements for these performance and the corrosion
device used to lock the products are very high for resistance of the
coupling and ensure both mechanical strength and PAM-GBLOBAL ® UNIGRIP
water tightness and mechanical pressure resistance. collar offer extended lifespan
stability of the pipework. The stability of the mechanical and operation safety over time.

Grips Stainless Steel + Treatment

Frames Galvanised Steel

Tightening plates Galvanised Steel

Screws Coated Steel - Class 8-8

PAM-GLOBAL ® SVE- Coupling


DN 50 - DN 200
Registry No: Z - 42.5-273
DN D L L1 A Weight Product Code
50 77 60 29 2 0,08 180953
80 103,5 65,5 32 2 0,11 180964
100 134 82 39,5 3 0,20 180954
125 161 103 50 3 0,31 180955
150 186 103 50 3 0,38 180956
200 238 114 55,5 3 0,50 180957

PAM-GLOBAL® SVE is tested in Red-coloured, polypropylene double It is manufactured in size DN 50


compliance with DIN 19543. rubber gasket is supplied with to DN 200 as prescribed by
NR-SBR sealing gaskets. construction and control regulations.

34
PAM-GLOBAL ® Connectors

PAM-GLOBAL ® Konfix
For Transition Connections
Registry No: Z - 42.5 - 240
ø Da
DN D1 D Connecting Pipe
L1 L Insert Depth Weight Product
mm Code
mm

50 57 72 40-56 20 58 35 0,11 155759


70 77 92 56-75 22 66,5 40 0,20 155790
80 82 92 56-75 22 71,5 45 0,16 180852
80* 81 112 83-90 20 88 60 0,17 179905
100 108 126 102-110 27,5 89,5 57 0,30 155833
125 132 151 125 35,5 108,5 65 0,64 155883

* For connection to the WC pipes and fittings in 90 mm diameter

Transitional connectors DN 50- The connections with these flexible Material: EPDM. Clamp made of
125 are devoted to connecting connectors are easy and safe: chrome steel material n° 1.4016.
cast iron ranges S and Plus to one pre-cut lid and a lip seal
other materials, be they steel inside (see figure).
or plastic.

PAM-GLOBAL ® Konfix-Multi
For Multiple Transition Connections
Registry No:. Z - 42.5 - 240
ø Da
DN D1 D Connecting Pipe
L1 L Insert Depth Weight Product
mm Code
mm

100 108 134 32-56 35,5 90,5 40 0,32 176811

To connect up to three iron pipe system DN 100. of chrome steel material n°


pipes, 32-56 mm, made of Material: EPDM. Clamp made 1.4016.
other materials to a cast

PAM-GLOBAL ® Multiquick
For Transition Connections Of Various Diameters
Registry No: Z - 42.5 - 240

DN øD1 øD2 øD3 øD4 ød1 ød2 ød3 ød4 H Weight Product
Code
100x70 117 111 101 81 108 104 94 74 107 0,15 176812

The Multiquick connector DN from 72 to 110 mm, to Several pre-cut options.


100x70 allows connections PAM-GLOBAL ® cast iron Material: EPDM. Clamp made
between other materials, with range DN 100 with a of chrome steel material
outside diameter ranking maximum outside diameter of n° 1.4016.
115 mm.

35
PAM-GLOBAL ® Application Guide

Simple Installation
With Greatest
Accuracy
PAM-GLOBAL® pipes up to DN
300 are generally supplied in
3 m length which can be cut to
length.
Where the pipes are cut on
site, they should be cut clean
and square and burrs removed.
Cut ends should be re-coated
with the EXTREM 1 one
component touch-up paint.

Cutting Techniques
PAM-GLOBAL® pipes can be readily cut by the use of a powered disc-cutter, or with wheel cutter.
Ensure correct grade of disc appropriate to cast iron are used, and that cutting wheels or saw blades are changed on
a regular basis. Angle grinders are not advisable for cast iron, but should they be used, make sure a secure hold of
the pipe is made. Warning: Chain cutters or snap cutters should not be used to serve the purpose

Hacksaw Pipe cutter Powered disc cutter Band saw


S range
DN50
DN75
DN100
DN125
DN150
DN200
DN250
DN300
DN400
DN500
DN600
Reciprocating saw can be used but is not so well adapted.
The pipe cutter from Ridgid or Rothenberger (see above) ensure fast, neat and square cutting.

Installation Instructions
For PAM-GLOBAL®
RAPID Coupling

1. Push the supplied 2. Push the next pipe spigot 3. Tighten the screw to “null
assembled coupling onto the into the other end of the gap” position, completely
pipe spigot up to the middle coupling. closed, with a ratchet spanner
spacing ring of the seal. or an electric screwdriver
36
PAM-GLOBAL ® Application Guide

PAM-GLOBAL ® Suspended pipe works shall in case of a standard


Bracketing be secured with fix points average 2.5 m between
recommendations for every 10 or 15 meters so floors, or more generally
cast iron pipe works. to prevent disconnection. every 15 m. The pipe work
illustrated here indicates
Pipework stability On vertical runs, waste the basic support and
A pipework is submitted to water or rainwater bracketing rules.
different forces liable to downpipes, the bracketing PAM-GLOBAL® includes a
affect its stability; for cast aims at preventing the comprehensive range of PAM-GLOBAL®
iron, the bracketing system pipework to fall over due clamps and accessories to Cast Iron Pipe
is designed to carry only to its own load. secure your cast iron
the weight of the pipe and The downpipes shall pipeworks.
its content (see table 1 on likewise be secured by two These accessories are
page 19). brackets spaced no more available in 3 sizes to
The bracketing rules aim at than 2 m, including one in match different load levels.
keeping the pipeworks the immediate vicinity of a For further technical details
stable, based on the pipe branch. please contact us.
loads. Pipe supports and PAM-GLOBAL® lines
fixings shall be adapted To address both pipe load experiencing pressure: Non
accordingly . and end thrust force, a gripped waste-water pipes
Basic rules: The pipes stack installed through open subject to internal pressure
brackets should be hoppers must be secured loads must be secured so
regularly spaced and the with fix points-like stack that they do not undergo
distance between two supports-to prevent the pipe dislocating forces are not
brackets should generally works from falling over. pushed out of axial
not exceed 2m. For buildings up to 5 alignment.
The pipes of 2 or 3 m storeys and a pipe diameter The adequate longitudinal
length should be supported DN 100, we recommend frictional connection can
with two brackets. Shorter to position the first stack be achieved with
pipe lengths should be fixed support pipe at the base of PAM-GLOBAL® grip collars.
with one or two brackets, the first floor, and then Please contact us for details.
depending on the diameter every subsequent fifth floor,
(or pipe load).
The brackets should be Downpipe
support
uniformly spaced in relation
Side View
to the junctions between
two elements. The distance
on either side of a coupling
should not be longer than
0.75 m.
Horizontal runs must be
adequately secured at
changes of direction and
wherever a fitting is
installed.

Top View

All dimensions
are in mm

37
PAM-GLOBAL ® Syphonic Roof Drainage System

38
PAM-GLOBAL ® Syphonic Roof Drainage System

Conventional
System

designed roof or channel outlets,


PAM-GLOBAL® EPAMS® which prevent air infeed into the
Syphonic Roof Drainage System pipe when the calculated volume
of rainwater has been reached.
The EPAMS® high-capacity With the EPAMS® system the air
syphonic roof drainage system is prevented from flowing (air cone
was developed approximately 35 buildup) into the pipes when the
years ago in Scandinavia. It is calculated rain volume has been
mainly used for draining roofs reached.
with large surface areas, such as The applicable regulation for the
factories, storage facilities, calculation of pipe sections for
shopping centres, as well as rainwater drainage is EN 12056.
buildings used for sports, leisure, However, the syphonic drainage
transportation and administration. system as a possibility for roof
The EPAMS® system is a The air in the middle of the outlet drainage is merely mentioned
technically mature development is sucked in through the eddies. here. Further details on the design
in roof drainage. It complies with This lowers the outlet's capacity and construction of such drainage
the DIN 1986-100 (version: May level. systems are not provided. This is
2008). Meanwhile, pressure-flow In contrast to open channel why the DIN 1986-100 has
roof syphonic systems, laid within drainage (according to EN universal validity. This directive
the PAM-GLOBAL® S pipe system, 12056), pressure-flow roof sets out guidelines for planning,
are being used by thousands in drainage pipes systematically calculation and construction, while
Germany. operate at the designed rain yield the corresponding system
The EPAMS® roof drainage system factor. When the pipe system has components of individual
has been taken into account by reached maximum capacity, the manufacturers have fundamental
Part 1 since 1988 and Part 2 geodetic height difference between distinctions with regards to
since 1995. In traditional the roof outlet and the transition assembly and mounting directives.
rainwater drainage systems, after pipe is used in open channel
the rain falls to the roof, it flows drainage in order to overcome
to the roof outlet or gutter via flow loss. This is why smaller
partially-filled drainage pipes. dimensions are required than in
Inside buildings, the maximum fill open channel drainage systems.
factor in rain water pipes is 0.7 The pipes can be laid without
(h/d = 0.7) according to EN gradients under the roof
12056. This fill factor means that construction due to the typical
traditional rainwater drainage operating conditions of these
How the
systems must have adequate pipe systems.
EPAMS® outlet
ventilation. There is no need for a wide-spread functions
Traditional flat roof outlets form branched pipe network. As a rule,
water eddies and cones of air. our EPAMS® high capacity roof
The undesired air infeed is affected drainage system, with all of its
by the Coriolis force (eddy benefits and advantages, offers
forming) and also depends on the extremely economical solutions.
atmospheric pressure, gravity and However, the pipes can only reach
the Earth's rotation. maximum capacity using specially

For additional information, please ask for a brochure.

39
PAM-GLOBAL ® Syphonic Rainwater Drainage System

Advantages of PAM-GLOBAL® Conventional Rainwater Drainage


Roof Drainage System

Pipes can be laid without Lower insulation costs DN100 DN100 DN100 DN100
gradients through smaller pipe
dimensions
High flow rate enables
self-cleaning Structural suspended
ceiling height can be
Pipe dimensions significantly reduced
reduced
Skirting protection savings
Limited number of pipe thanks to fewer downpipes PAM-GLOBAL® EPAMS® System
trenches, shafts or buried pipes
Price advantage gained by
Easier installation shortens lower material and labor DN 50 DN 80
construction time costs
DN 100
Slab can be cast immediately

Roof Outlets (In Compliance With DIN EN 1253)


PAM-GLOBAL® UNO 24/DN 80 Stainless Steel Flat-Roof Outlet

Available as one or two component models, stainless steel


Material no: 1.4301, with flanges

Capacity:
Up to 24 l/s

Accessories:
Galvanized steel connector flange, 600x800 mm
(for trapezoidal sheet metal roof)
Stainless steel connector flange
as a loose and fixed flange combination, ø325 mm
(for concrete roof)
Inspection chamber (for inverted or landscaped roofs, where
allowed by local regulations)
Heating strip, PUR 10 Watt, 230 V

40
PAM-GLOBAL ® Syphonic Rainwater Drainage System

Available as one or two component models,


stainless steel

PAM-GLOBAL® UNO 24 Material no: 1.4301, with flanges


Stainless Steel Outlet-
Edge Gated Horizontal Capacity:
Connection 1 l/s to 5 l/s (DN50)
1 l/s to 8 l/s (DN80)

Available in one or two component models, cast iron

Capacity:
PAM-GLOBAL® INO-
Up to 24 l/s (DN 80)
GGG Flat-Roof Outlet
In Cast Iron
Accessories:
Insulating bodies made of cellular glass for thermal insulation
Heating strip, 20 Watt, 230 V

HDE gutter outlets DN 50, special production DN 70


Rounded design, aluminium, copper and stainless steel A4,
PAM-GLOBAL® material 1.4571, stainless steel outlets also available with
Gutter Outlet connector flanges.

All run-offs with leaf traps and reinforced outlet supports.

Capacity:
Up to 4 l/s (DN 50)
Up to 8 l/s (DN 80)

41
REFERENCES

Airports Commercial and Admin. Build.


• A380 Maintenance Hangar / Airport • Ak MerkezShopping Center (Turkey)
(Germany) • ARBED (ARCELOR) Administrative Building
• Airport Terminal (Germany) (Luxemburg)
• Airports Vnukovo and Sheremetyevo 3 • Arcades Mall Center (Hungary)
(Russia) • Auchan commercial center (Russia)
• Domodedowo Airport (Russia) • Auchan Commercial Center, Luxembourg
• Frankfurt Airport (Germany) (Luxemburg)
• Tour A, Luxembourg/Kirchberg • Banque d'Investissement Européenne,
(Luxemburg) Luxembourg (Luxemburg)
• Bayrische Landesbank, Luxembourg
(Luxemburg)
Bridges
• BMW - World (Germany)
• Beverbach Talbrücke / bridge (Germany)
• Business Center “Diplomat Hall” (Ukraine)
• Bridge Köröshegy (Hungary)
• Business Center Strassen (Luxemburg)
• Theistalbrücke / bridge (Germany)
• Business Park Sofia (Bulgaria)
• Zoobrücke Köln / bridge (Germany)
• Business Park Varna (Bulgaria)
• Casper Business Center (Turkey)
Hospitals • CK Business Center Leudelange (Luxemburg)
• Hospital Samara (Russia) • Dedeman Hotel and Shopping Mall (Turkey)
• Moscow Hospital (Russia) • Dunajski Mozaik Commercial Centre
• Novokutsnesk Hospital - Siberia (Russia) (Slovenia)
• Oncological Clinic (Russia) • Exhibition Center (Germany)
• Reko Hospital (Russia) • Forum Shopping Mall (Turkey)
• Gazpron Tower (Russia)
• General Post Office (Germany)
Hotels • Gimat Shopping Mall (Turkey)
• 2 Hilton Hotels (Turkey) • IKEA Mega-Mall Rostov/Don Moscow,
• Club Mediterannee (Turkey) Ekaterienburg (Russia)
• Elysee Hotel (Germany) • IKEA Mega-Mall St. Petersburg, Novosibirsk,
• Falez Hotel (Turkey) Krasnodar, Perm (Russia)
• Grand Hotel Mariott (Russia) • Kanyon Shopping Mall and Residentials
• Hilton Hotel (Turkey), (Ukraine) (Turkey)
• Hilton Hotel (Turkey) • Kursker Railway station Shopping Center
• Holiday Inn (Turkey) (Russia)
• Hotel “Premier Palast” (Ukraine) • Office “Surgutneftgaz” (Russia)
• Hotel Corinthia (Russia) • Office “UralSib” (Russia)
• Hotel Hilton (Azerbaidjan) • Petrovsky Passage (Russia)
• Hotel Ritz Carlton (Russia) • Sabanci Centre (Turkey)
• Hotel Svjosdny (Russia) • Shopping Center “Köln Arkaden”
• Hotel Theatralnaya (Ukraine) (Germany)
• Hyatt Regency Hotel (Turkey) • Shopping Center City Park (Slovenia)
• Kempiski Ciragan Hotel (Turkey) • Shopping Center Phoenix Center (Germany)
• Kosmos Hotel (Russia)
• Mariottt Hotel (Turkey)
• Movenpick Radisson Hotel (Turkey)
• Penta Lufthansa Hotel (Turkey)
• Pierre Loti Hotel (Turkey)
• Raddisson SAS Royal Hotel (Russia)
• Ramada Inn Crowne Plaza (Turkey)
• Sheraton Hotel (Turkey), (Turkey)
• Swiss Hotel Bosphorus (Turkey)
• Yalta Hotel (Russia)

42
Productions Sites
• Audi cars Works (Germany)
• Cadburys Factory (Russia)
• Eon RWE Energiezentralen (Netherlands)
• Factory “Tetra Pack” Lobny ( Moscow region) (Russia)
• Factory General Motors (Russia)
• Factory Volkswagen (Russia)
• Perfetti van Melle Sweet Factory (Netherlands)
• Porsche Cars (Germany)
• Renault Factory (Turkey)
• Technology Park (Slovenia)

Public Buildings
• Administration Building of Luxembourg County (Luxemburg)
• Centre Socio-Culturel, Luxembourg (Luxemburg)
• Chambre of Commerce (Luxemburg)
• Cours des Comptes Européenne (Luxemburg)
• European Community Conference Center (Luxemburg)
• German Embassy (Russia)
• Latvian National Library (Latvia)
• Metro Line (Turkey)
• N.A.T.O. Bases (Turkey)
• Palais de Justice de Paix, Esch/Alzette (Luxemburg)
• Parliament and Government Building (Germany)
• Parliament Building (Hungary)
• Philharmonie Music Hall (Luxemburg)
• Railway Station "Lehrter Bahnhof" (Germany)
• Railway Station Central (Ukraine)
• Rijaset Islamske Zajednice (Bosnia)
• Sabanci University (Turkey)
• Youth Centre Astana (Kazakhstan)

Residential Build.
• Baranovitchi Military Housing (Russia)
• Baytur Residentiazl Buildings (Turkey)
• Housing “Panorama Plaza” (Latvia)
• Housing complex “Begowaya”, “Kutusov Riviera”, “MIRAX-Park" (Russia)
• Housing complex “Jantarny Gorod” (Russia)
• Mashattan Towers (Turkey)
• Moscow City, pilot 13, Federation Tower A (Russia)
• Moscow City, pilot 4, Imperia Tower (Russia)
• Moscow City, pilot 9, Gorod Stolitz, High Rise Building (Russia)
• Slonim Military Housing (Russia)
• Vila Urbana (Slovenia)

Stadiums
• Ice Arena (Russia)
• Olimpia Stadium (Turkey)
• Olympic Sport Center (Latvia)
• Olympic Stadium (Ukraine)
• Schalke-Arena Stadium (Germany)
• StadiumAllianz-Arena (Germany)

43
Contents

SAINT-GOBAIN HES - Cast Iron Pipe Systems 2-3

PAM-GLOBAL® - Soil and Drain 4

Cast Iron Specification 5

About Us 6

PAM-GLOBAL® Systems 8

PAM-GLOBAL® S Pipes - Coating 9

PAM-GLOBAL® Fittings - Coating 10-11

Quality Certifications 12-13

Fire Protection 14-15

Noise Insulation 16-17

Environmental Awareness 18

PAM-GLOBAL® S - Products 19-30

PAM-GLOBAL® - Couplings, Grip Collars and Connectors 31-35

Installation Instructions 36-37

PAM-GLOBAL® EPAMS® Syphonic Roof Drainage System 38-41

References 42-43

7
Cast Iron Drainage Systems

Fire resistant, durable, long-lasting, silent and


low-maintenance PAM-GLOBAL®
cast iron drainage pipes are the world’s number
one choice for wide-ranging areas of usage.

Business Centers / Car Parkings

Hotels / Residential Buildings

Public Buildings / Shopping Malls

Hospitals / Manufacturing Plants

Schools / Gymnasiums and stadiums

Saint-Gobain PAM
Head Office
91. Avenue de la libération
54076 NANCY Cedex
France

Tel: +33 (0)3 83 95 20 00


Fax: +33 (0)3 83 95 29 51
Web: http://www.pam-cast-iron.com
January 2012