You are on page 1of 3

PAH8001EI-2G Product Brief

PixArt Imaging Inc. Optical Heart Rate Detection Sensor

PAH8001EI-2G: Optical Heart Rate Detection Sensor


General Description Key Parameters
The PAH8001EI-2G is a high performance and low power
Parameter Value
CMOS-processed optical sensor with Green LED and Operating Junction -20 to +60
integrated Digital Signal Processor serving as a Heart Rate Temperature (°C)
Detection sensor. It is based on optical technology which Interfaces I2C, 2-Wire SPI, 4-Wire SPI
measures the variation of human blood movement in the
Input Clock (MHz) 6.8Mhz
vessel and using this measured data to estimate heart
Supply Voltage (V) VDDM: 3.3 – 3.6
beat rate.
VDDIO: 1.62 – 3.6
Average Supply Current Run: 1.5
Key Features
(mA) Sleep1: 0.16
 Heart rate detection function Note: including LED current Sleep2: 0.04
 Ultra-low power consumption with power saving without I/O toggling Power down: 0.015
modes during no touch movement period Frame Rate (fps) Up to 3000
 LPT sleep1
Heart Rate Measurement
 LPT sleep2 Range (bpm)
30 - 210
 Flexible sleep rate control
Package Size (mm) 3.0 x 4.7 x 1.0
 Flexible communication interface
 I2C
 4-wire SPI
Ordering Information
 2-wire SPI Part Number Package Type
 I2C interface up to 1 Mbit/s PAH8001EI-2G 16-pin LGA Package
 SPI interface up to 1 Mbit/s
 Hardware reset support
 Hardware power down support
 Integrated chip-on-board LED with wavelength of
525nm For any additional inquiries, please contact us at
http://www.pixart.com/contact.asp
Applications
 Healthcare/Sports wearable device
 Photoplethysmogram waveform
 Smart wearable eg. watch, wrist-band

Version 1.1 | 13 Sep 2015 | 30000EN

PixArt Imaging Inc. http://www.pixart.com


All rights reserved. Any portion in this paper shall not be reproduced, copied, or transformed to any other forms without permission. 1
PAH8001EI-2G
PixArt Imaging Inc. Optical Heart Rate Detection Sensor

1.1 System Overview


The heart rate detection of PAH8001 is based on optical measurement technique that uses a light source and a detector to
detect cardio-vascular pulse wave that propagates through body. The detected signal (pulse wave) is called
photoplethysmography and its acronym in some literatures is PPG or PTG. The PPG signal reflects the blood movement in
the vessel, which goes from the heart to the fingertips through the blood vessels in a wave-like motion. Therefore, we can
use this PPG signal to estimate heart rate. This optical based technology could offer significant benefits to healthcare
application as it is noninvasive yet accurate and simple to use.
1.2 Block Diagram

LED Driver POWER ON


Green LED RESET
CMOS IMAGE
TOUCH/ SENSOR VDDI O

AND POWER CONTROL


SCI

VOLTAGE REGULATOR
WAKE UP VDD18V
VDD28V
CSN_ID1
4-wire SPI SCK VSS
Interface SDIO
SDI_ID0 DIGITAL
SERIAL SIGNAL
PROCESSOR VDDM
2-wire SPI SCK INTERFACE
&
Interface SDIO ALGORITHM

I2C SCK
Interface SDIO CONTROL REGISTER OSCILLATOR

Figure 1. PAH8001 Functional Block Diagram

Figure 2. System Block Diagram

Version 1.1 | 13 Sep 2015 | 30000EN

PixArt Imaging
All rights Inc. http://www.pixart.com
reserved. Any portion in this paper shall not be reproduced, copied, or transformed to any other forms without permission. 2
Thank you for using www.freepdfconvert.com service!

Only two pages are converted. Please Sign Up to convert all pages.

https://www.freepdfconvert.com/membership

You might also like