ALONG X-DIRECTION:

1-1 2-2. 3-3.


PIER 1 PIER 2 PIER 3 PIER 1 PIER 2 PIER 1 PIER 2 PIER 3
-1.613 -5.64 -1.633 -5.235 -5.27 -1.633 -5.954 -1.637
-5.214 -5.629 -5.139 -4.908 -5.508 -5.433 -5.953 -5.476
-4.051 -4.214 -4.218 -7.273 -11.301 -4.196 -4.454 -4.504
-4.303 -4.219 -3.966 -8.679 -10.595 -4.479 -4.445 -4.238
-9.655 -9.664
-8.371

15.181 19.702 14.956 35.75 50.709 15.741 20.806 15.855

ALONG Y-DIRECTION:
A-A B-B
PIER 1 PIER 2 PIER 3 PIER 1 PIER 2 PIER 3
-3.014 -2.974 -2.991 -2.415 -6.546 -2.483
-7.239 -7.426 -4.111 -6.271 -6.813 -6.205
-6.328 -2.645 -6.036 -5.497 -6.708 -6.574
-6.958 -7.281 -7.024 -6.077 -7.197 -5.784
-6.695 -7.548 -6.419 -5.341
-7.626 -6.29
-7.599 -7.085
23.539 27.021 42.935 20.26 47.058 26.387
INDUCED SHEAR STRESSES (Vi)

Length of Induced Shear


Wall Thk
Wall Pier SF (KN) Stress
(m) pier (m) (N/mm2)
11 1 15.181 0.45 1.35 0.0250
2 19.702 0.45 1.35 0.0324
3 14.956 0.45 1.35 0.0246
22 1 35.75 0.45 2.025 0.0392
2 50.709 0.45 2.475 0.0455
33 1 15.741 0.45 1.35 0.0259
2 20.806 0.45 1.35 0.0342
3 15.855 0.45 1.35 0.0261
AA 1 23.539 0.45 1.563 0.0335
2 27.021 0.45 1.563 0.0384
3 42.935 0.45 2.8 0.0341
BB 1 20.26 0.45 1.563 0.0288
2 47.058 0.45 2.676 0.0391
3 26.387 0.45 1.563 0.0375
Vi = 0.0455 maxm

SHEAR STRENGTH OF UNREINFORCED MASONRY (Fvm)

Allowable Unreinforced
Shear Wall Thk Length of Masonry
Wall Pier Stresses (m) pier (m) Shear
(N/mm2) Strength (KN)

11 1 0.1 0.45 1.35 60.75


2 0.1 0.45 1.35 60.75
3 0.1 0.45 1.35 60.75
22 1 0.1 0.45 2.025 91.13
2 0.1 0.45 2.475 111.38
33 1 0.1 0.45 1.35 60.75
2 0.1 0.45 1.35 60.75
3 0.1 0.45 1.35 60.75
AA 1 0.1 0.45 1.563 70.34
2 0.1 0.45 1.563 70.34
3 0.1 0.45 2.8 126.00
BB 1 0.1 0.45 1.563 70.34
2 0.1 0.45 2.676 120.42
3 0.1 0.45 1.563 70.34

SHEAR RESISTANCE DUE TO HORIZONTAL BARS (Fvh)


No. Of Area of
No. Of bars/band fs
Wall Pier Horizontal bar/band fy (N/mm2) (N/mm2) Fvh (KN)
Band (mm2)
11 1 4 2 100.57 415.00 232.4 93.49
2 4 2 100.57 415.00 232.4 93.49
3 4 2 100.57 415.00 232.4 93.49
22 1 4 2 100.57 415.00 232.4 93.49
2 4 2 100.57 415.00 232.4 93.49
33 1 4 2 100.57 415.00 232.4 93.49
2 4 2 100.57 415.00 232.4 93.49
3 4 2 100.57 415.00 232.4 93.49
AA 1 4 2 100.57 415.00 232.4 93.49
2 4 2 100.57 415.00 232.4 93.49
3 4 2 100.57 415.00 232.4 93.49
BB 1 4 2 100.57 415.00 232.4 93.49
2 4 2 100.57 415.00 232.4 93.49
3 4 2 100.57 415.00 232.4 93.49

SHEAR RESISTANCE DUE TO VERTICAL BARS (Fvv)


Wall Pier n1 d1 (mm) n2 d2 (mm) fc fy fs
(N/mm2) (N/mm2) (N/mm2)
corner 8 8 2 4.75 5 415 232.4
middle 8 8 0 0 5 415 232.4
T 15 8 0 0 5 415 232.4

Now,
Fv = Fvm+Fvh+Fvv

Wall Pier Fvm Fvh Fvv Fv =


Fvm+Fvh+Fvv
11 1 60.75 93.49 15.31 169.55
2 60.75 93.49 14.07 168.31
3 60.75 93.49 15.31 169.55
22 1 91.13 93.49 15.31 199.92
2 111.38 93.49 15.31 220.17
33 1 60.75 93.49 15.31 169.55
2 60.75 93.49 14.07 168.31
3 60.75 93.49 15.31 169.55
AA 1 70.34 93.49 15.31 179.13
2 70.34 93.49 15.31 179.13
3 126.00 93.49 15.31 234.80
BB 1 70.34 93.49 15.31 179.13
2 120.42 93.49 26.38 240.29
3 70.34 93.49 15.31 179.13
168.31 KN (minm)

Total Shear Capacity = 168.31 KN


Wall thickness = 0.35 m
Length = 1.35 m

Shear Strength (v) = 0.36 N/mm2 > Vi So,OK


201.1429 50.28571
Fvv (KN)

15.31
14.07
26.38