You are on page 1of 209

Design of footing

Square footing
1 Dimensions :- SBC 250 KN/m2
Pu (load from column) 1500 KN P 1000 KN
Size of column γs 20 KN/m2
Lx 600 mm Φ 30 degree
Ly 300 mm sin(30) 0.5
Muc (column) 150 KN
fck 25 N/mm2
fy 500 N/mm2

Depth of foundation
Df 1.388888889
Dfpro 1.4
2 Load calculation:-
P 1000 KN
SELF WEIGHT 100 KN
TOTAL LOAD 1100 KN

3 Size of footing:-
Area 4.4 m2
B 2.1 m2 2097.6176963403 mm
Size (2.1m x 2.1m) 2100.00

4 Upward pressure intensity


Pu 340.9 KN/m2

5 Caculation for maxm projection


e 0.1 m 100 mm
x (from figure) 1m 1000 mm

6 BM
Mu 357.548471 KNm 357548470.9671 Nmm

7 Depth of footing
d 226.288243 mm
d 407.3188374 mm
d' 50 mm
D 457.3188374 mm
Dpro 500 mm
dpro 450 mm

8 Checks
Punching shear
b1 750 mm 0.75 m
d1 1050 mm 1.05 m
U 268.4659091 KN

9 Vu 1231.534091 KN
bo 3600 mm
Tv 0.760206229 N/mm2
Tc 1.25 N/mm2 SAFE

Main R/F
Ast 1904.305934 mm2 assume 16mmΦ
N 9.471240704
Npro 8 Nos
0.523599 radians
Design of footing (Rectangular Footing)
1 Dimensions:- 5 Depth calculation
P (load from column) 566.9333 KN Pu 850.4 KN d
Size of column B 230 mm 0.23 m d
450 mm 0.45 m dpro
SBC 200 KN/m 2
D
γs 18 KN/m 3

fck 25 N/mm2 Check for 2 way shear


fy 500 N/mm2 6 B'
Φ 30 ° 0.5236 D'
SinΦ 0.5 Uplift pr. U
Vu
2 Load Calculation τv=Vu/boxd
W 623.6267 KN τc

3 Area of foundation
A 3.118133 m2 x= 0.71462 -1.0546
B 1.6 m 1600 mm 8 Main R/F
L 2m 2000 mm Ast1
Ap 3.2 1B 1.65925 asuume
xb 0.685 xl 0.775 N
Np
4 Upward pressure intensity
pu 265.75 KN/m2 Ast2
N
Bending moment calculation Np
Mu1 99.75724 KNm
Mu2 159.6161 KNm
epth calculation
154.9271 mm
278.8689 mm OR dmin 290
340 mm
400 mm

heck for 2 way shear 7 Check for 1 way shear


570 mm 0.57 L 2000 1600
790 mm 0.79 b 345 435
119.6672 KN Vu 183367.5 184962
730.7328 KN Tv 0.2696581 0.26575
0.790152 N/mm2 %P 0.1395525 0.12815625
1.25 N/mm2 SAFE Tc 0.2826868 0.274709375 Naruto Naruto
0.15 0.29 0.15 0.29
0.1395525 0.2826868 0.128156 0.274709
0.25 0.36 0.25 0.36

692.4569 mm2 Astmin= 768 Ast 820.2 SPACING 153.2111


10 mmΦ
10.44311
19 Nos

1116.414 mm2 Astmin 960 Ast 1116.42 SPACING 140.6994


14.2147
21 Nos
1 Restricted "B" of footing 2m
P1 (load from column) 840 Pu1 1260 KN 7 Depth calculation
P2 (load from column) 1200 KN Pu2 1800 KN d 417.317787
Size of columns B 400 mm 0.4 400 0.4 dpro 930
400 mm 0.4 400 0.4 d' 60
SBC 150 KN/m2 D 990
γs 18 KN/m 3

fck 20 N/mm2 B 400


fy 415 N/mm2 D 400
Φ 30 ° 0.523599 8 Check for 2 way shear
SinΦ 0.5 B' 1330
C/C Bet. Columns 5m D' 1330
Uplift pr. U 360.8556
2 Load Calculation
W 2244 KN Vu 1439.1444
3 ẍ= 2.9411765 τv=Vu/bod 0.29087727
τc 1.11803399
4 Area of foundation
A 14.96 m2 x= 1.733908 9 Main R/F
B 2m 2000 mm Ast1 399.433122
L 7.5 m 7500 mm asuume Φ 16
Ap 15 1B 3.867816 -2.13391 N 11.8172545
L1 0.8088235 L2 1.691176 Np 12
Ast2 1773.59289
5 Upward pr. intensity N 11.8172545
pu 204 KN/m2 Np 12
pu 408 KN/m Ast3 2851.35566
N 14.1817001
6 S.F. & B. M. Calc. Np 15
SF L1 LHS L1 RHS L2 LHS L2 RHS
330 -930 1110 -690 10 Design of Transverse R/F
Upward pr. intensity
X 2.2794118 pu 398.230088
BMmax -926.4706 926.5 Mu 104.659845

B.M. at C1 at C2 Area of trans. R/F


133.45588 583.456 Ast 320.518874
BMmax (max of 3) 926.5 N 5.90862726
Design of shear R/F
mm OR dmin 290
mm 0.93
mm
mm

mm 1.33
mm 1.33
KN

Pu 1800
N/mm2 169.244
N/mm2 SAFE

Astmin= 2376 Ast 2376 SPACING 169.244

Astmin 2376 Ast 2376 SPACING 169.244

Astmin 2376 Ast 2851.4 SPACING 141.0268

sverse R/F

KN/m2

Φ1 12
Φ2 25
dtrans 911.5
Astmin 1188 Ast 1188 SPACING 169.244