What is the purpose an FAI?
Yellow – Required
Blue – Conditionally Required
White – Optional
1 – Goodrich Part Number
The actual part number that is being FAI
2 – Part Name
The part name listed on the drawing
3 – S/N
The Serial Number for the part being FAI.
7 – Drawing Revision
The revision of the Goodrich drawing for this part that this FAI is being performed to.
8 – Additional Changes
Always ‘N/A’
14 – Type of FAI
What is a Full FAI?
– All Notes and Dimensions with the exception of reference
dimensions on the drawing are measured and/or inspected at
the appropriate step in the process.
•The index of part numbers or subs that need to be on this list are all parts
from the parts list. If the part is MS put N/A for the FAI Report Number,
otherwise all the parts must all have documented FAI’s on file.
•All columns must be filled out. If NOT the “FAI Complete” Check box can
NOT be checked and “FAI Not Complete” must be checked
Sign off -19, 20, 21, 22, 23, and 24
Is the page number and grid location on the Engineering drawing. For
Example: sh2 – C6, sh1 – A10. For multiple sheet numbers make sure
you put in a sheet number.
7 – Characteristic Designator
If applicable, record characteristic type (e.g., key, flight safety, critical,
major, etc.).
8 – Requirement
Enter the specified requirement for the characteristic for example,
drawing dimensional characteristics with nominal and tolerances, for
notes just specifying note number will be enough (Note 2).
More Example – Characteristic Evaluations
9 – Results
Enter measurement(s) obtained for the characteristics.
•For Multiple Characteristics list each characteristic as individual values or list once with the minimum and
maximum of measured values attained. If a characteristic is found to be nonconforming then that characteristic
must be listed separately with the measured value noted.
•If a Design Requirement requires verification testing, then the actual results will be recorded on the form. If a
laboratory report or certificate of test is included in the FAI, then these results need not be written on the form,
record the reference number in this field. The laboratory report or certificate of test must show specific values for
requirements and actual results.
•For metallurgical characteristics with visual verification requirement that are rated against standard photographs,
list the photo number of the closest comparison. A statement of conformance is acceptable (record the reference
number in this field).
•For processes that require verification per Design Characteristic, include statement of compliance (e.g.,
certification of compliance, verification indicator such as “accept”, etc.).
•For part marking, ensure that marking is legible, correct in content and size and properly located, per applicable
specification.
11 – Nonconformance #:
Record a nonconformance document reference number (IE – Waver
Number) if the characteristic is found to be nonconforming.
http://www.sae.org/iaqg/publications/faq9102.htm