Professional Documents
Culture Documents
Doc-Tc Ie DT 013008 En-0 0 PDF
Doc-Tc Ie DT 013008 En-0 0 PDF
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0
Fecha Edición / Edition Date: 18/01/13
Edición / Edition: Joan Perelló
Fecha Revisión / Revision Date: 18/01/13
Revisión / Revision: Carmelo Poyatos
Aprobación / Approval: Jaume Borràs
INDEX
INDEX..................................................................................................................................................................................1
INTRODUCTION................................................................................................................................................................2
SETTINGS...........................................................................................................................................................................3
CONSOLE MENU...............................................................................................................................................................5
LIST MENU.......................................................................................................................................................................12
OPTION MENU.................................................................................................................................................................12
SERIAL MENU.................................................................................................................................................................12
GRAPHIC MENU..............................................................................................................................................................13
CONNECT MENU.............................................................................................................................................................13
INTRODUCTION
This document presents the USB interface software with several tools that permit to control,
program and get information from the Fermator controllers.
SETTINGS
Install the USB driver CP210x_VCP_Win_XP_S2K3_Vista_7.exe, it will create a virtual serial
port in Windows which configuration can be seen in the Device Manager.
To acces to the Device Manager press:
Pressing this keys the system properties window will appear, then select the Device Manager
and configure the port as shown in the figure.
COM-LPT (windows)
Note: The port number assignment is automatic, in the case that is higher than which can be
selected from the application WinConsola, it can be modified manually (Port
configurationadvanced options).
Select the Language, the serial COM port where the interface is connected to the computer,
and the communication baud rate. Once configured execute the Run command.
If communication is established correctly the application will enable the menus as shown in the
image below.
The menus can be selected from the menu bar or from the toolbar, when a communication is
established a log bar is created that shows information about the device at internal level.
CONSOLE MENU
Connect the programming tool to the VVVF “SERIAL PORT” connection (#13,14,15,16).
The green 4 pole connector is to connect to the VVVF3 and VVVF4.
The phone jack connector (RJ-11) is to connect to the VVVF5.
Once the tool is connected it is supplied by the VVVF and it will show its software version
Fermator VVVF and the Software release of the VVVF connected to Fermator VVVF
Vers. 127 . 5010 .
There are 2 main menus TEST and PROG menus with different submenus depending on the
VVVF version.
The submenus are available pressing TEST or PROG key only with the VVVF-5, with older
versions the variables are in the main menu.
The TEST submenus are:
To select the submenu press the ENTER key and pressing this key the next parameter will be
shown.
The different options and variables are explained in the next pages.
Pressing the keys the screen will show the safety force of the
programmed re-opening function in case of obstruction reflected in a scale from 4 to 15.
or the opening and closing maximum speeds mm/s respectively.
DOOR POSITION Door position in centimeters from the closed door position. So, when
0 the door is opened it will show the clear entrance.
(Clear entrance plus 7 pulses if the door has a skate for automatic landing door. For example a
door with a clear opening of 800mm will show 87 pulses with the door opened.)
It is useful to check the encoder performance.
It must be the same as the DIP-switch programmed. If not, there must be a problem with the
component, the socket connection or the control.
From left to right, the information offered is the following:
1) 1 or 2 Inputs 2) Automatic/Semiautomatic - 3) Left-Central / Right 4) Master / Slave
OPTIONS 1 It informs about the status of some options (see them in page 10):
87654321
“0” if option not activated (OFF) and “1” if activated (ON).
8 7 6 5 4 3 2 1
Parking Aljo Compact Close Robusta 2 motors Photocell Hong Kong
mode option reducted priority door timer Firefighting
OPTIONS 2 It informs about the status of some extra options (see them in page 10):
87654321
“0” if option not activated (OFF) and “1” if activated (ON).
8 7 6 5 4 3 2 1
PM Encoder PM Motor 125V LB door Voltage Reopening CE8P V30F
door protection NO/NC
OPTIONS 3 It informs about the status of some extra options (see them in page 10):
87654321
“0” if option not activated (OFF) and “1” if activated (ON).
8 7 6 5 4 3 2 1
PM Encoder PM Motor 125V LB door Voltage Reopening CE8P V30F
door protection NO/NC
INPUTS It shows if the control inputs connected to the VVVF are activated or not.
0100 0000 “0” if input not activated (OFF) and “1” if activated (ON).
By means this screen we can check if the door operator works correctly with the lift controller.
From left to right, the information offered is:
Close Open Re-open Test Encoder Slow closing Floor level Autoadjustment
SHORTCIR.CYCLES No. times over current protection activated.(Short circuit or motor blocked)
PHOTOCELL FAULT No. times the photocell has been obstructed more than 2 minutes.
BLOCKAGE CYCLES No. times the door has been blocked at opening.
The next field are only activated for the VVVF-4 control version:
The PROG menu Press ENTER to access the next parameter and or
keys to change the VALUES or go back to the previous parameter.
Some parameters and options are only available with some software versions as they
did not exist previously.
PARAMETERS
Ma x.sp ed
l.o pe ni ng
De c. op
en in g
O PE N
Ac ce
Skat esp ace En dop eni spg ace
O ENP ED CLO SED
M ax. spe ed
D
i ng
e c .cl osi ng
c el. cl os
C LO S ED
A
A U TO M A TIC S E M IA UT O M AT IC
(standard values)
CLEAR ENTRANCE 087 It shows the door’s clear entrance. (cm)
OPEN LENGTH 002 The space at the final opening at slow speed. (in cm)
CLOSE LENGTH 004 The space at the final closing at slow speed. (in cm)
HOLD TORQUE OPEN 045 The voltage applied to the motor to keep the door opened. (V)
Change this value just enough to maintain the door in opened position.
H. TORQUE CLOSE 045 The voltage applied to the motor to keep the door closed. (V)
OPENSKATE SPEED100 The speed applied to the motor at opening. (Up to 200 mm/s).
LENGTH SKATE 007 The required space to open the skate. (in cm)
GEAR RATIO 10:N 10 Gear ratio when special cogged pulley is used
(Ratio in tenths 10 = 1:1)
No.PAIR POLES 3 Nº.of pair poles. (For example 3 pair for a 6 poles motor)
SPEED LIM.OPEN 700 Speed limit at opening. (mm/s)
SPEED LIM.CLOSE 400 Speed limit at closing. (mm/s)
S.LIMIT OPEN 2 200 Speed limit at opening (Only if USA option enable) (mm/s)
S.LIMIT CLOSE 2 200 Speed limit at closing (Only if USA option enable) (mm/s)
LENGTH PFO AUX 005 Additional space at the final open movement. (only VVVF5)
LENGTH PFT AUX 005 Additional space at the final close movement. (only VVVF5)
OPTIONS 1
PHOTOCELL TIMER This bit enables or disables the Photocell Timer timeout
performance.
HK FIREFIGHTING Firefighting mode in some countries to run in slave mode in the
startup.
2 MOTORS Special conditions for 2 motors door system.
ROBUSTA DOOR Special conditions for special heavy doors.
CLOSE PRIORITY Priority at closing if open and close signals applied at the same
time.
COMPACT REDUCT Special conditions for a Compact door system with reduction gear.
ALJO OPTION Special conditions for ALJO systems (Advanced Logic Joint
Operation).
PARKING MODE Activates the parking mode with door closed (no motor force).
OPTIONS 2
V-30F Activates the V-30F mode with signals de-activated with voltage.
CE8P Activates the reduced opening with emergency voltage.
NC REOPEN INPUT Reopen input (#21) with Normally Closed contact to activate it.
CYCLES LAST T.S. Protection of the voltage parameters against automatic changes.
LB DOOR Special conditions for Linear Bus door system.
125V DOOR Special conditions for door system supplied to 125V.
USA Activates the special software functions according to USA norms.
CAR LOCK Activates the special conditions when car door lock is
detected(TEC4047 and newer)
EUNAP Activates the unified software for SCH door systems in EU, NA and
AP (TEC4047)
LAST ALARM Code of the last alarm activated (see codes in TEST MENU).
MOTOR PM Activates the special control software for door systems with the
synchronous Permanent Magnet motor (only VVVF5).
There are different possibilities depending on the doors weight, number of motors, mechanical conditions,
skate modifications, etc. The particular conditions could lead to small modifications in the standard
parameters.
PARAMETER VVVF5
Side Central
OPEN LENGTH 5 5
CLOSE LENGTH 5 5
OPEN ACCEL. 8 4
CLOSE ACCEL. 4 3
OPEN BRAKE 8 5
CLOSE BREAK 5 4
APROX SPEED 50 60
OPEN SKATE SPEED 80 80
LENGTH SKATE 21 21
MIN.VOLT.OPENING 200 200
MIN.VOLT.CLOSING 100 100
HOLD TORQUE OPEN 200 220
HOLD TORQUE CLOSE 200 220
MIN.SKATE VOLTAGE 120 120
LENGTH PFO AUX 0 5
LENGTH PFT AUX 5 5
Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 11 / 13
Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0
LIST MENU
OPTION MENU
SERIAL MENU
GRAPHIC MENU
CONNECT MENU
The server will show the IP address which is the same that
have to be configured in the Menu Connect with the computer
port.