TECHNICAL DOCUMENT

DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0
Fecha Edición / Edition Date: 18/01/13
Edición / Edition: Joan Perelló
Fecha Revisión / Revision Date: 18/01/13
Revisión / Revision: Carmelo Poyatos
Aprobación / Approval: Jaume Borràs

INDEX
INDEX..................................................................................................................................................................................1
INTRODUCTION................................................................................................................................................................2
SETTINGS...........................................................................................................................................................................3
CONSOLE MENU...............................................................................................................................................................5
LIST MENU.......................................................................................................................................................................12
OPTION MENU.................................................................................................................................................................12
SERIAL MENU.................................................................................................................................................................12
GRAPHIC MENU..............................................................................................................................................................13
CONNECT MENU.............................................................................................................................................................13

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 1 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

INTRODUCTION
This document presents the USB interface software with several tools that permit to control,
program and get information from the Fermator controllers.

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 2 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

SETTINGS
Install the USB driver CP210x_VCP_Win_XP_S2K3_Vista_7.exe, it will create a virtual serial
port in Windows which configuration can be seen in the Device Manager.
To acces to the Device Manager press:

Windows Key + Pause/Inter

Pressing this keys the system properties window will appear, then select the Device Manager
and configure the port as shown in the figure.

COM-LPT (windows)

Note: The port number assignment is automatic, in the case that is higher than which can be
selected from the application WinConsola, it can be modified manually (Port
configurationadvanced options).

To configure the port in the WinConsola execute the Settings menu.

Select the Language, the serial COM port where the interface is connected to the computer,
and the communication baud rate. Once configured execute the Run command.

If the communication is not well established a window advise will be shown:

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 3 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

If communication is established correctly the application will enable the menus as shown in the
image below.

The menus can be selected from the menu bar or from the toolbar, when a communication is
established a log bar is created that shows information about the device at internal level.

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 4 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

CONSOLE MENU

With the console three main objectives can be achieved:


1.-To see the value of the VVVF parameters and options.
2.-To detect possible errors in the system and the signals
coming from the lift controller.
3.-To modify the internal program parameters changing the
different opening and closing movement curves.

Connect the programming tool to the VVVF “SERIAL PORT” connection (#13,14,15,16).
The green 4 pole connector is to connect to the VVVF3 and VVVF4.
The phone jack connector (RJ-11) is to connect to the VVVF5.
Once the tool is connected it is supplied by the VVVF and it will show its software version
Fermator VVVF and the Software release of the VVVF connected to Fermator VVVF
Vers. 127 . 5010 .

There are 2 main menus TEST and PROG menus with different submenus depending on the
VVVF version.
The submenus are available pressing TEST or PROG key only with the VVVF-5, with older
versions the variables are in the main menu.
The TEST submenus are:

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 5 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

The PROG submenus are:

To select the submenu press the ENTER key and pressing this key the next parameter will be
shown.

The different options and variables are explained in the next pages.

Pressing the keys the screen will show the safety force of the
programmed re-opening function in case of obstruction reflected in a scale from 4 to 15.
or the opening and closing maximum speeds mm/s respectively.

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 6 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

The TEST menu

Press or to move up/down parameters by parameter.

SUPPLY VOLTAJE 230V


This indicates the rectified voltage supply, and it informs if the protection fuse is blown.

MOTOR CURRENT It will show the motor current.


ACTIVE ALARM Alarm code if an error is detected. The alarm code references are:
00 - 1- Driver 2- Bl.Open 4- Bl.Close 8- Friction 16- Temperature 32- Autoadjust 64- Encoder

DOOR POSITION Door position in centimeters from the closed door position. So, when
0 the door is opened it will show the clear entrance.
(Clear entrance plus 7 pulses if the door has a skate for automatic landing door. For example a
door with a clear opening of 800mm will show 87 pulses with the door opened.)
It is useful to check the encoder performance.

TEST PHOTOCELL It informs about the photocell status.


BLOCKED / FREE

PROGRAMMING DIP It informs about the DIL switches programming. O


N
1 2 3 4

0101 “0” if OFF mode and “1” if ON mode.

It must be the same as the DIP-switch programmed. If not, there must be a problem with the
component, the socket connection or the control.
From left to right, the information offered is the following:
1) 1 or 2 Inputs 2) Automatic/Semiautomatic - 3) Left-Central / Right 4) Master / Slave

OPTIONS 1 It informs about the status of some options (see them in page 10):
87654321
“0” if option not activated (OFF) and “1” if activated (ON).

8 7 6 5 4 3 2 1
Parking Aljo Compact Close Robusta 2 motors Photocell Hong Kong
mode option reducted priority door timer Firefighting

OPTIONS 2 It informs about the status of some extra options (see them in page 10):
87654321
“0” if option not activated (OFF) and “1” if activated (ON).

8 7 6 5 4 3 2 1
PM Encoder PM Motor 125V LB door Voltage Reopening CE8P V30F
door protection NO/NC

OPTIONS 3 It informs about the status of some extra options (see them in page 10):
87654321
“0” if option not activated (OFF) and “1” if activated (ON).

8 7 6 5 4 3 2 1
PM Encoder PM Motor 125V LB door Voltage Reopening CE8P V30F
door protection NO/NC

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 7 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

INPUTS It shows if the control inputs connected to the VVVF are activated or not.
0100 0000 “0” if input not activated (OFF) and “1” if activated (ON).

By means this screen we can check if the door operator works correctly with the lift controller.
From left to right, the information offered is:
Close Open Re-open Test Encoder Slow closing Floor level Autoadjustment

OUTPUTS It shows if any output of the VVVF is activated.


0100 0000 “0” if output not activated (OFF) and “1” if activated (ON).

From left to right, the information offered is:


Opened Closed Photocell Obstruction Status - - -

FUNCTION Identify the movement of the door:


1 0.Waiting 1.Opening 2.Open 3.Closing 4.Middle opened 5.Stopped 6.Blockage 7.CDL
8.Spring force 9.Stop COM 10.Syncro learning

SHORTCIR.CYCLES No. times over current protection activated.(Short circuit or motor blocked)
PHOTOCELL FAULT No. times the photocell has been obstructed more than 2 minutes.
BLOCKAGE CYCLES No. times the door has been blocked at opening.

The next field are only activated for the VVVF-4 control version:

TEMPERATURE Temperature in the VVVF power rectified area (ºC).


COMP. CLOSE Close compensation factor of the adaptive process.
COMP. OPEN Open compensation factor of the adaptive process.
SUPPLIER CODE Supplier identification code.
SERIAL NUMBER Identification serial number for each unit.
To identify every unit it is needed the supplier code/Serial number Ex. 1/125008.
HARDWARE Hardware version of the VVVF control
VERSION
LOT REFERENCE Lot number identification.
LEARN CYCLES No. learning cycles made by pressing the autoadjustment button.
REOPEN CYCLES No. re-open cycles.
HOURS No. working hours.
No.MAIN FAULTS No. connections to the mains supply or blackouts suffered.
No.OVERTEMPERAT No. overtemperature protection activated (Active if T>74ºC).
U
FRICTION Friction value detected when making the autoadjustment function.

CLEAR OPENING N-1 Clear entrance detected one autoadjustment before.


CLEAR OPENING N-2 Clear entrance detected two autoadjustments before.
CLEAR OPENING N-3 Clear entrance detected three autoadjustments before.

TOTAL CYCLES No. cycles done by the door.

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 8 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

The PROG menu Press ENTER to access the next parameter and or
keys to change the VALUES or go back to the previous parameter.

Some parameters and options are only available with some software versions as they
did not exist previously.
PARAMETERS
Ma x.sp ed

l.o pe ni ng

De c. op
en in g
O PE N

Ac ce
Skat esp ace En dop eni spg ace
O ENP ED CLO SED

M ax. spe ed

D
i ng

e c .cl osi ng
c el. cl os
C LO S ED

A
A U TO M A TIC S E M IA UT O M AT IC

(standard values)
CLEAR ENTRANCE 087 It shows the door’s clear entrance. (cm)

OPEN LENGTH 002 The space at the final opening at slow speed. (in cm)
CLOSE LENGTH 004 The space at the final closing at slow speed. (in cm)

OPEN ACCELERATION 010 The opening acceleration.. (in dm/s2)


CLOSE ACCELERATION 010 The closing acceleration. (in dm/s2)
OPEN BRAKE 008 The opening deceleration. (in dm/s2)
CLOSE BRAKE 004 The closing deceleration. (in dm/s2)

END SPEED 070 The approximation speeds at opening/closing movements. (in


mm/s)

0 VOLTAGE 055 The Inverter Voltage reference. (V)


V/F OPEN 020 The Voltage/Frequency ratio at opening.
V/F CLOSE 015 The Voltage/Frequency ratio at closing.
We recommend to do not modify these 3 parameters without clear comprehension
about their influence.
These 3 parameters does not exist when a VVVF-PM Motor is used.

HOLD TORQUE OPEN 045 The voltage applied to the motor to keep the door opened. (V)
Change this value just enough to maintain the door in opened position.

H. TORQUE CLOSE 045 The voltage applied to the motor to keep the door closed. (V)
OPENSKATE SPEED100 The speed applied to the motor at opening. (Up to 200 mm/s).
LENGTH SKATE 007 The required space to open the skate. (in cm)
GEAR RATIO 10:N 10 Gear ratio when special cogged pulley is used
(Ratio in tenths 10 = 1:1)
No.PAIR POLES 3 Nº.of pair poles. (For example 3 pair for a 6 poles motor)
SPEED LIM.OPEN 700 Speed limit at opening. (mm/s)
SPEED LIM.CLOSE 400 Speed limit at closing. (mm/s)
S.LIMIT OPEN 2 200 Speed limit at opening (Only if USA option enable) (mm/s)
S.LIMIT CLOSE 2 200 Speed limit at closing (Only if USA option enable) (mm/s)

MIN.VOLT.OPENING 50 Minimum voltage applied at the final opening movement (V)


MIN.VOLT.CLOSING 50 Minimum voltage applied at the final closing movement (V)
SKATE VOLTAGE 60 Voltage applied at the dragging skate movement. (V)
PARKING DELAY 240 Delay time before activation of Parking mode. (s)

LENGTH PFO AUX 005 Additional space at the final open movement. (only VVVF5)
LENGTH PFT AUX 005 Additional space at the final close movement. (only VVVF5)

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 9 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

OPTIONS 1

PHOTOCELL TIMER This bit enables or disables the Photocell Timer timeout
performance.
HK FIREFIGHTING Firefighting mode in some countries to run in slave mode in the
startup.
2 MOTORS Special conditions for 2 motors door system.
ROBUSTA DOOR Special conditions for special heavy doors.
CLOSE PRIORITY Priority at closing if open and close signals applied at the same
time.
COMPACT REDUCT Special conditions for a Compact door system with reduction gear.
ALJO OPTION Special conditions for ALJO systems (Advanced Logic Joint
Operation).
PARKING MODE Activates the parking mode with door closed (no motor force).
OPTIONS 2

V-30F Activates the V-30F mode with signals de-activated with voltage.
CE8P Activates the reduced opening with emergency voltage.
NC REOPEN INPUT Reopen input (#21) with Normally Closed contact to activate it.
CYCLES LAST T.S. Protection of the voltage parameters against automatic changes.
LB DOOR Special conditions for Linear Bus door system.
125V DOOR Special conditions for door system supplied to 125V.
USA Activates the special software functions according to USA norms.
CAR LOCK Activates the special conditions when car door lock is
detected(TEC4047 and newer)
EUNAP Activates the unified software for SCH door systems in EU, NA and
AP (TEC4047)
LAST ALARM Code of the last alarm activated (see codes in TEST MENU).

MOTOR PM Activates the special control software for door systems with the
synchronous Permanent Magnet motor (only VVVF5).

PROTECTION It protects the modified parameters.


NO : means that a new auto adjustment would automatically bring back all the standard parameters adjusted
with the door, losing all the modifications done with the console.
PARTIAL : this protection will only protect the energy parameters not the movement ones.
FULL : to save all the modifications.
Remember that you have to protect the modified parameters against the autoadjustment function that
will establish the standard ones for the type of door.

SAVE YES / NO It saves the changed parameter values.

VVVF5: The voltage parameters values are in Volts=Value/10.

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 10 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

List of parameters for some VVVF drives:

PARAMETER VVVF 4+ 2 Motors Motor Compact 125V VVVF 3 VVVF 4


125V Reduct Door
Side Central
OPEN LENGTH 2 2 5
CLOSE LENGTH 3 4 9
OPEN_ACCEL. 10 8 24
CLOSE ACCEL. 10 6 22
OPEN BRAKE 8 9 20
CLOSE BRAKE 4 5 12
END SPEED 70 70 180
0 VOLTAGE 55 55 50 80 40 80 55 65
V/F OPEN 20 20 15 24 10 24 27 27
V/F CLOSE 15 15 10 20 9 20 19 19
HOLD TORQUE OPEN 45 45 40 75 40 75 45 55
HOLD TORQUE CLOSE 45 45 40 50 40 50 45 55
OPEN SKATE SPEED 100 100
LENGTH SKATE 7 7
GEAR RATIO 10 10 28
No.PAIR POLES 3 3 2
MIN.VOLT.OPENING 700 700 1680
MIN.VOLT.OPENING 400 400 1120
MIN.VOLT.OPENING 50 70 60
SKATE VOLTAGE 60 70 60

There are different possibilities depending on the doors weight, number of motors, mechanical conditions,
skate modifications, etc. The particular conditions could lead to small modifications in the standard
parameters.

PARAMETER VVVF5
Side Central

OPEN LENGTH 5 5
CLOSE LENGTH 5 5
OPEN ACCEL. 8 4
CLOSE ACCEL. 4 3
OPEN BRAKE 8 5
CLOSE BREAK 5 4
APROX SPEED 50 60
OPEN SKATE SPEED 80 80
LENGTH SKATE 21 21
MIN.VOLT.OPENING 200 200
MIN.VOLT.CLOSING 100 100
HOLD TORQUE OPEN 200 220
HOLD TORQUE CLOSE 200 220
MIN.SKATE VOLTAGE 120 120
LENGTH PFO AUX 0 5
LENGTH PFT AUX 5 5
Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 11 / 13
Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

LIST MENU

With the list three main objectives can be achieved:


1.-To see the value of the VVVF parameters and options.
2.-To detect possible errors in the system and the signals
coming from the lift controller.
3.-To modify the internal program parameters changing the
different opening and closing movement curves.

Their value can be changed clicking on it directly.


Then possible range is shown.

The big difference with the Console menu is that the


parameters are displayed in a list, this facilitates a better
comfort to consult or modify parameters.

OPTION MENU

It informs about the active options.

It also permits to Enable or Disable each one.

Some of them could be unavailable depending on the software


version of the VVVF, so they will appear as not selectable.

SERIAL MENU

This feature offers the possibility to control the door by the


serial communication port.
The program sends the proper codes for every selected signal
when the CONTROL bit is activated. This part of the PC
Console program just shows how it works this protocol.

The serial control is an open protocol that offers the possibility


to control everything (inputs signal activation, output reading,
internal memory information reading, …) just by 4 wires.
To get the control it have to be enabled, active the control bit
and active the control order:
Open, close, reopen or forced closing (slow close).

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 12 / 13


Tel. +34 977 774 065 • Fax. +34 977 771 615 • www.fermator.com • NIF. A-43128784
TECHNICAL DOCUMENT
DOC-TC.IE.DT.013008.EN
Software PC WinConsola
Versión / Version: 0.0

GRAPHIC MENU

This feature provides the possibility to show graphically the


speed ramps and tension ramps of the circuit.

Modifying the programming parameters the changes that


occur can be observed in the graphic.

CONNECT MENU

The program provides the possibility to connect remotely


through a server, to implement that function run the
application ServerWinVVVF.exe. Then select the local
computer's serial port and configure a port for the connecting
Network.

The server will show the IP address which is the same that
have to be configured in the Menu Connect with the computer
port.

Tecnolama s.a. • Ctra. Constantí km.3 • 43206 Reus, Spain Pág. 13 / 13