Operation
K 604244 E / 01
1-11.220.200
OPERATION USER INTERFACE MX-UI
Summary This document contains information about the handling of the User Interface
MX-UI for MX-GC with Variodyn VF22BR/VF33BR/VF30BR/VF50BR/VF85BR.
Herein you will find a description of the functions of the keys and LEDs, informa-
tion on parameters and their setting values as well an explanation of test func-
tions.
Modification: 01
KA No. 107004
KA Date: 23.08.2002
Restrictions This Manual is the property of INVENTIO AG and shall only be used by SCHINDLER personal or authorized SCHINDLER agents
for purposes which are in the interest of SCHINDLER. This design and information is our intellectual property. Without written
consent, it must neither be copied in any manner, nor used for manufacturing, nor communicated to third parties. Application for
such consent should be addressed to: INVENTIO AG, Postfach, CH-6052 Hergiswil NW
Page 1 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Page 2 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
1 General Notes
Danger !
• Do not use the keys on MX-UI when the elevator is in operation (no parame-
ter changes or test functions).
• Observe the outlines regarding "CMOS/MOS Handling" when working with
PCBs.
Caution !
In order to prevent a loss of previously changed parameter values at a reset or
when the installation is switched ON and OFF, always execute the function
"EndCo".
Note !
The personnel is familiar with the product and has acquired the necessary techni-
cal skills through proper training.
Summary This chapter contains further information about MX-GC and VF22BR/VF33BR/
VF30BR/VF50BR/VF85BR.
Page 3 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Page 4 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
LM Load measurement
LOC Locarno
LON Local Operating Network / (LED display)
LONC LON Car (LED display)
LONLMS-3 Load measuring system with hitchplate
LONP LON Periphery (LED display)
LR-D LED direction down
LR-U LED direction up
LTRT LED indication door trigger
LUEISK LED monitoring current in safety circuit
LUET LED, display bridging of door safety circuit
MA Mode display (key with LED display)
MH Hoisting motor
MX-UI User interface
P Parameter (key with LED display)
PCT Parameter configuration table
PMA350 Permanent magnet synchronous motor for Aramid ropes
PMS230 Permanent magnet synchronous motor for steel ropes
REC/RH Inspection / recall (LED mode indication)
RSK/RSK1 Relay safety circuit (LED display)
RUET/RUET1 Relay bridging of door safety circuit (LED display)
Rx Receive data (Ethernet LED display)
SH Main contactor (mains)
SINCOS Sine wave generator (speed tacho)
SK Safety circuit
T Test (key with LED display)
T1 ....T5 Parts/sections of the safety circuit (LED displays)
T1/T2 Door1/door2 (LED display LON communication to door1/door2)
Tx Transmit data/data output (Ethernet LED display)
VecSys Vector drive regulation system
+ Increase (key)
- Decrease (key)
List of Relevant Abbreviations and their Meaning
Page 5 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
MX-UI User
Interface
3
COM SK
Chip Card
T1 T2 T3A T3B T4 T5 1
5 Ethernet RSK
Rx
RSK1
Lift ID VRSK
CCS Tx
DUEISK-A
4 C
A
LON
1 0 LR-U T1 2
JMOF
LUET T2
JLF
BATT LR-D L
JKFM LONP
LTRT
JRVM 24 V RUET G
RUET1 REC/RH
+ -
6 7
9 MA DC KOS T P
Page 6 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
DUEISK-A
VRSK
DUEISK red Short-circuit or no voltage supply in
the safety circuit
DUEISK-A: Reset switch (must be
activated after clearing a short-circuit
in the safety circuit)
Safety Circuit
A
red not lit Normal state
T1 blinks No communication with drive
T2
lit Drive has error or is not configured
L
LONP T1 / T2 green not lit Normal state
G blinks Door opens or closes
REC / RH
lit Door is open
red not lit Normal state
blinks No communication with door drive
lit Door drive has an error
L green not lit Elevator control is not available
blinks A service is active (INSP, JAB etc.)
lit Elevator control is in normal state (N)
Page 7 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Page 8 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Note !
LEDs (yellow) are lit when the corresponding service is active!
Priorities: JMOF > JLF > JKFM > JRVM
24 V
24 V green lit 24 VDC available
Voltage Supply
Page 9 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
MA DC KOS T P
+ Increase value
- Decrease value
MA The mode displays are described on the following
pages
• LED is lit when the corresponding key function is
active
Function Keys with LED / 7 Segment Displays
Note !
"+ / -" keys can be used for navigation too.
Summary The description of the following mode displays is based on a potential final version
of the software, exhausting all functional possibilities. Depending on the MX-GC
SW version (1.20, 1.30 etc.) installed, not all mode displays described below
may be active.
Page 10 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Mode Display
Mode--: Current position of car (floor)
"MA"
Page 11 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
15
Temporal blockage
16
Permanent blockage
17
Test
18
Evacuation using "Sicurtronic"
19
Bridging of door interlocking
20
Docking (control) travel
Mode6:
Frequency Converter State
0
Undefined State
1
Not available
2
Pre-commissioning executed
3
Pre-commissioning not executed
4
Commissioned
5
In operation
6
Idle
7
Error (not fatal)
8
Temporarily unavailable
Page 12 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Confirmation
Adjustment of
Leveling First entry Select target floor using "+/-" keys
Accuracy "KOS" "1".." z"
Confirmation
Page 13 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
4 Parameters
Note !
• Based on the value of parameter P1 (setting), the correct inverter parameters
will be selected from the VecSys database
• Based on the value of parameter P2 (setting), consisting of the last 4 digits of
the Id. No., the correct motor parameters will be selected from the VecSys da-
tabase.
• In case the Id. No. of the hoisting motor is not specified in CADI – Motor Con-
trol - Help - “FC Motor Data Sheets”, VecSys does not contain the relevant
motor parameters. The setting of P2 has to be “0”.
• During the commissioning, the settings, respectively the parameters will auto-
matically be downloaded/initialized either as PCT or as COS values.
Page 14 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Page 15 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
P37 Nominal Motor Nominal hoisting motor current. Automatically set as soon
Current [A] as P2 receives the last 4 digits of the hoisting motor Id.
Number. If P2 is “....0”, the value specified on the motor
plate must be entered.
In case the MH has more than one motor winding: Be
careful to enter the correct current value specified for the
motor winding which will be supplied by the FC (usually
the 4 pole / 2 pole pair winding, if available)
P46 Pole Pairs Number of hoisting motor pole pairs. Automatically set as
soon as P2 receives the last 4 digits of the hoisting motor
Id. Number.
Examples:
“....2” for MH with 1500 rpm (50 Hz)
“....3” for MH with 1000 rpm (50 Hz)
“...33” for EuroLift PMS230 motor type
“...33” for EuroLift PMA350 motor type
If P2 is “....0”, the value deduced from the speed rpm
specified on the motor plate must be entered
P54 Impu Rev Number of signals (pulses or sine waves) from motor
tacho/speed tacho sent to “Motor Control” (VecSys) per
one revolution of the hoisting motor.
Examples:
“.2000” (pulses) for IG2000
“10000” (pulses) for IG10000
“.2048” (sinusoidal signals) for sine wave generator 2048
with EnDat function (encoder SINCOS 2048 En-
Dat) e.g. with PMS230, PMA350
P55 Gear Ratio Gear ratio IW. Effective value of the gear ratio.
Examples:
“13.67” for IW 41/3
“17.34” for IW 52/3
“....1” for gearless machine e.g. PMS230, PMA350,
FM280
P56 Trac Dia [m] Traction sheave diameter DD
Examples:
“.0.45” for traction sheave with diameter 450 mm
“.0.57” for traction sheave with diameter 570 mm
“.0.41” for traction sheave with diameter 410 mm e.g.
PMS230
P57 Roping Reeving factor KZU.
Examples:
“....2” for KZU 2:1
“....1” for KZU 1:1
“....2” for KZU 4:2
Page 16 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
P58 Inertia [kg*m²] Total inertia of all moving parts at rated load.
Examples:
• New Installation:
During commissioning, the value P58 will be automati-
cally initialized as PCT-/Chip card parameter and
therefore does not need to be entered.
• Modernization:
If the value is not available as PCT or chip card pa-
rameter, it will be calculated when executing test "t4"
and then written into P58
P59 LM Type Load Measurement.
“ ....0” if no load measurement available
“ ....1” for load measurement using contacts
“ ....2” for load measurement using DMS
“ ....3” for HP_DMS (Hitch Plate DMS) e.g. EuroLift
P60 Nominal Load Value in kg.
P83 Acceleration Acceleration [mm/s2]. Default value = 600
P84 Deceleration Deceleration [mm/s2]. Default value = 600
P85 Code Type Depending on country-specific regulations the value in
“Code Type” allows different handling of parameters.
“....0” for EN81 European Standard, Asia, Africa
“....1” for US Standard A17
Further information can be found in “CADI Help”
P89 Encoder Type Type of motor/speed tacho.
“....0” for pulse transmitter type e.g. IG2000/IG10000
“....1” for sine wave tacho e.g. Sine wave gen. 2048
“....2” if no motor tacho available
“....3” for sine wave generator 2048 with EnDat function
(encoder SINCOS 2048 EnDat) e.g. with
PMS230, PMA350
P90 ETSL Type Deceleration monitoring at the hoistway ends for elevators
with short buffer stroke.
“ ....0” for “RSE” centrifugal switch with RSE contact
and relay
“ ....1” for “ETSL” independent speed monitoring with
optical sampling at the hoistway ends
“ ....2” for no deceleration monitoring at the hoistway
ends
P91 Gear Type Gear type.
“ ....0”: for gearless machine
“ ....1”: for worm gear
“ ....2”: for planetary gear
Page 17 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
P92 Inverter Input Input voltage to FC. Mains voltage or adapter transformer
Voltage [V] output voltage as input to the FC.
“....2” for 380 VAC
“....3” for 400 VAC
“....4” for 415 VAC
P93 Shaft Info Selection of shaft information system.
Setting “ ....0” for PHUET, PHNR-D, PHS
“ ....1” for KUET, KS, KS1
“ ....2” for DOM
“ ....3” for KUET/2KUET e.g. MX-GC
Based on the value in P93, the system expects the corre-
sponding shaft info signals
P94 Brake Setting Selection of brake type
“ ..100” for SB Einschütz (one-contactor solution) e.g.
with hoisting motor PMS230, PMA350 (EuroLift)
and with brake module for MGB 36..180 VDC,
MGB 205 VDC and MB 3 x 400 VAC.
Based on the number entered, the correct brake pa-
rameters will be selected from the database and set as
operating values
P95 Nominal speed Nominal speed of the car.
[mm/s] During commissioning, the value P58 will automatically be
initialized as chip card parameter
P96 Phase Dir Direction of the motor rotational field at FC output.
"....0" for all MH except PMS230, PMA350: This value
"....1" ("0" / "1") should not be inverted because the
direction of the rotational field at the FC output is
determined by test “t3”
Car
" ....1" for PMS230, PMA350 only:
Traction sheave turns
clockwise when the elevator
travels upwards
Car
" ....0" for PMS230, PMA350 only:
Traction sheave turns
counterclockwise when the
elevator travels upwards
Page 18 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Caution !
• Changing the value of parameter P150 causes all motor parameters to be
erased.
• Reading the state of p150 proceed as follows: Select P150 and leave the
menu using the MA key.
Page 19 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
5 Tests
Test Display The 7-segment display at the end of the tests should be evaluated as follows:
Display Interpretation
Test unsuccessfully terminated
Test Display
Page 20 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Note !
• If a test is terminated too early by the system, please refer to the product re-
lated document “Diagnostics”.
• If a test is terminated too early and an error number is displayed, the inter-
pretation of the error can be found in the related diagnostics document.
Page 21 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Page 22 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Note !
Acceptance
The following acceptance tests are only listed for the sake of completeness.
For a detailed description of the acceptance test procedure, please refer to the
product related document “Acceptance Tests”.
T6 EN81 Zero Current Required by EN81. Monitoring MH for current flow with
Test car stationary. Current flow results in blocking of FC.
Execution of the test according to “Acceptance Tests”
K 604298
T14 Brake Test Confirming that, with an emergency stop the elevator
brakes properly. Execution of the test according to
“Acceptance Tests” K 604298
T19 Friction on Traction Checking the friction between suspension elements
Sheave and traction sheave. Execution of the test according to
“Acceptance Tests” K 604298
T26 Speed at Door Function test “Door bridging” during leveling at floor.
Opening Execution of the test according to “Acceptance Tests”
K 604298
T32 Travel into the Confirming that buffer and car can withstand the al-
Buffer lowed buffer impact speed. Execution of the test ac-
cording to “Acceptance Tests” K 604298
T33 Overspeed Confirming that the pre-contacts trigger when pre-
Governor contact speed is reached. Execution of the test ac-
cording to “Acceptance Tests” K 604298
T34 GBV Tripping Confirming that the Overspeed governor actuates the
Speed safety gear when tripping speed is reached.
Execution of the test according to “Acceptance Tests”
K 604298
T37 Monitoring Travel Confirming that the travel is terminated after a maxi-
Time mal operating time of the drive. Execution of the test
according to “Acceptance Tests” K 604298
T41 Braking Distance Displays the braking distance from test “t14”. Execu-
tion of the test according to “Acceptance Tests”
K 604298
T51 Freeze LON Tree Saves the LON nodes. In case a new LON node is
added, T51 has to be repeated. Further explanations
can be found in "MX-GC Diagnostics" K 604107
T53 LED Test MX-UI Select T53. All LEDs and 7-segment displays light up
as long as the “T” key is pressed
T55 Not Available Reserve
Page 23 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
Note !
Load Measurement
To get the correct LMS Commissioning Instruction Number, please refer to:
• Overall Commissioning Miconic MX-GC with Variodyn VF22BR/VF33BR
K 604105.
• Overall Commissioning Miconic MX-GC with Variodyn VF30BR/VF50BR/
VF85BR K 604160.
Commissioning T80 Nom. Load [kg] Rated (nominal) load. Select T80 and confirm by
Steps pressing the “T” key. The rated load value will then be
Example displayed by MX-UI (may be corrected)
LONLMS3
T81 Basic Load Car is empty. Select T81 and confirm by pressing the
“T” key. MX-UI displays “T81 1” which confirms that
basic load, empty car, has been registered
T82 Full Load Load the car with 40% to 100% of the rated load (pref-
erable 100%). Select T82, confirm by pressing the “T”
key.
Check that the current load [kg] is displayed. If not,
correct the value. Confirm by pressing the “T” key.
MX-UI displays “T82r“.
Wait a couple of seconds. The display “T82 1” on
MX-UI will then confirm that the load has been regis-
tered
T83 System Check Reduce the load in the car to between 30 % and 70 %
of the previously used load for test T82. Select T83,
con-firm by pressing the “T” key.
Check that the current load [kg] is displayed. If not,
correct the value. Confirm by pressing the “T” key.
MX-UI displays “T83r “.
Wait a couple of seconds. The display “T83 1” on
MX-UI will then confirm that the load has been regis-
tered
T84 Empty Bottom Unload the car. Select T84, confirm by pressing the “T”
key. MX-UI displays “T84r “. KFM mode gets automati-
cally activated and, if required, the car will be sent to
the lowest floor.
Wait a couple of seconds. The display "84 1"on MX-UI
will confirm that empty car at the lowest floor has been
registered
T85 Empty Top Car is empty. Select T85, confirm by pressing the "T”
key. MX-UI displays "T85 r ". KFM mode gets auto-
matically activated and, if required, the car will be sent
to the uppermost floor.
Wait a couple of seconds. The display "T85 1” on
MX-UI will confirm that empty car at the uppermost
floor has been registered
Page 24 - 25
User Interface MX-UI: LEDs - Parameters - Test Functions INVENTIO AG
Operation
K 604244 E / 01
T86 Empty Middle Car is empty. Select T86, confirm by pressing the "T”
key. MX-UI displays "T86 r ". KFM mode gets auto-
matically activated and, if required, the car will be sent
to the middle floor.
Wait a couple of seconds. The display "T86 1” on
MX-UI will confirm that empty car at the middle floor
has been registered.
T87 Adaptation Test Important: This test must not be carried out on in-
Empty Car stallations with LMS Type "Hitch Plate" e.g. Euro-
Lift
Car is empty. Select T87, confirm by pressing the "T”
key. MX-UI displays "T87 r ".
Wait a couple of seconds. The display "T87 1” on
MX-UI will confirm that adaptation test of empty car
has been executed
T89 Status Display The 7-segment display indicates which commissioning
steps were successful. Select T89, confirm by pressing
"T”. MX-UI could display the following:
Successful tests
Unsuccessful
tests
Test 87 86 85 84 83 82 81 80