Service Directive

August 24, 2012


BEHRINGER X32 Input Channel Noise Issue
ISSUE: X32 Console exhibits heightened noise floor on Input Channel 16, 32 or both.
CAUSE: DC Power cable bundle routed too close to input preamplifiers.
REMEDY: Re-route cable bundle away from microphone preamplifier boards as indicated below.

1 2 3

Remove end panels and set aside. Remove screws holding top panel Remove screws along bottom edge
on side of console. under arm rest.

4 5 6

Remove Center Screw on chassis Remove screws holding top panel Lift top cover from FRONT of console
bottom next to center support. along rear of console. and note position of cables shown here.

7 8 9

Carefully cut tie wrap holding cables. Using a screwdriver, remove ribbon Pull cables away from area indicated.
cable as shown.

10 11

Replace ribbon cable in socket by Finished rework shows rerouted cables


aligning pins. and connected ribbon cable.

WARNING: Disconnect Power Supply. Do Not Attempt Unless Qualified.