Off-Highway Equipment
Dan Spurgeon
Cab Climate Systems
Earthmoving Division
Caterpillar Inc.
Affected Models
• 120M (S/N: R9A1-126; B9C1-1430; R9C1-110; B9N1-354; B9W1-209; D9W1-513)
• 120M Series 2 (S/N: M921-107; M9C1-729; M9H1-444; R9N1-218; R9W1-197)
• 12M (S/N: B921-554; R9B1-127; B9F1-1497; B9R1-1388)
• 12M Series 2 (S/N: F9B1-220; F9M1-481; R9P1-199; R9S1-360)
• 12M Series 3 (S/N: N9B1-423; N9F1-669; N9P1-221; N9R1-280)
• 12M Series II (S/N: R9R1-105)
• 140M (S/N: B9D1-76001; B9G1-1056; D9G1-1668; B9M1-1078)
• 140M Series 2 (S/N: M9D1-1844; R9G1-372; M9J1-952; R9M1-559)
• 140M Series 3 (S/N: N9D1-758; N9G1-228; N9J1-510; N9M1-475)
• 14L (S/N: B941-228)
• 14M (S/N: B9J1-1450; R9J1-1857)
• 14M Series 3 (S/N: E9S1-250; N9S1-235)
• 160M (S/N: B9E1-1182; B9L1-506; B9T1-183; D9T1-1492)
• 160M Series 2 (S/N: M9E1-409; M9K1-425; R9L1-258; R9T1-349)
• 160M Series 3 (S/N: N9E1-110; N9K1-127; N9L1-151; N9T1-212)
• 16M (S/N: B9H1-866; R9H1-993)
• 16M Series 3 (S/N: E9Y1-235; N9Y1-230)
• 18M Series 3 (S/N: N9A1-227; E9W1-228) » EARTHMOVING DIVISION » CONFIDENTIAL YELLOW 4 4
Quality Update – Evaporator Connection Stud
Issue
The existing 325-4416 Stud fitted to the 452-0537
Conditioner Gp can fail on certain Articulated
Trucks. If the existing 325-4416 Stud fails it can be
replaced with existing parts.
Resolution
Replace the 325-4416 Studs and joint seals with
new parts. New seal p/n’s are 327-0282 and
327-0283.
Service Letter
TEBE6219-02
Affected Models
• 725C 2 (S/N: 2L600145-00146 & 2T300241-00347)
• 730C 2 (S/N: 2L700204-00308 & 2T400426-00640)
• 730C 2 EJECTOR (S/N: EJ 2L800162 & 2T500137-00149)
• 735C (S/N: TFJ00257-00299, 301-318)
• 740C EJECTOR (S/N: LFN00277-00278 & TFN00189-00198)
• 745C (S/N: LFK00916-01096 & TFK01486-01661)
Issue
Certain Articulated Trucks with 472-4671 Air Conditioner
are unable to service the fresh air filter due to clearance
issues. 443-4695 Right Panel Assembly is blocking the
wing nuts that retain the 259-3222 HVAC Fresh Air Filter.
Before
Resolution
1.Remove panel from the machine for modification
2.Trim the panel per the measurements provided
3.Ensure that the edges are smooth after performing the
modifications to panel
4.Reinstall panel and confirm that there is adequate
clearance to remove the air filter.
Issue
An improved accumulator assembly is now available for
select ADT. The improved accumulator has a larger orifice
hole to increase the oil circulation ratio (OCR).
Resolution
Replace the existing accumulator assembly with 513-7188
accumulator assembly. Also replace 320-0562 refrigerant
dryer due to system being open to the outside environment.
Affected Models
• 725C 2 (S/N: 2L0061-00146 & 2T0031-00314)
• 730C (S/N: T281-90106; LFF1-495; TFF1-1413)
• 730C EJECTOR (S/N: LFH1-UP; TFH1-160)
• 730C 2 (S/N: 2L00071-00293 & 2T0041-00591)
• 730C 2 EJECTOR (S/N: 2L00081-up & 2T00051-00142)
• 735B (S/N: L4D1-462; T4P1-490; E4R1-UP)
• 735C (S/N: TFJ00001-00292 & LFJ00001-00254)
• 740B (S/N: L4E1-41945; GLH1-143; E4S1-139)
• 740B EJECTOR (S/N: L4F1-530; T4S1-383)
• 740C EJECTOR (S/N: LFN00001-00278 & TFN00001-00197)
• 745C (S/N: LFK00001-01075 & TFK00001-01638)
» EARTHMOVING DIVISION » CONFIDENTIAL YELLOW 7 7
Service Update – Improved Sealing for Air
Conditioner Group
Issue
An improved design to the conditioner group
prevents dust/dirt from entering.
Resolution
Replace 302-8727 seal with a newer version,
along with adding a 520-6380 bracket.
Affected Models
• 950K (S/N: R4A1-UP; J5M1-UP; FER1-UP)
• 950M (S/N: EMB1-UP; ENE1-UP; XCJ1-UP; FTR1-UP; LCR1-UP; J1S1-UP)
• 950M Z (S/N: HE81-UP)
• 962K (S/N: T6A1-UP; FLL1-UP; X4T1-UP)
• 962M (S/N: EJB1-UP; JYD1-UP; LSE1-UP; RCL1-UP; J2S1-UP; F2T1-UP)
• 962M Z (S/N: SA81-UP)
• 966K (S/N: PBG1-UP; TFS1-UP)
• 966K Series XE (S/N: NGX1-UP)
• 966M (S/N: EJA1-UP; DYC1-UP; R8D1-UP; LMM1-UP; KJP1-UP; L8R1-UP)
• 966M Series XE (S/N: P6C1-UP; B8P1-UP)
• 972K (S/N: PEM1-UP; Z4W1-UP)
• 972M (S/N: L8E1-UP; LSJ1-UP; GGN1-UP; A8P1-UP; JPR1-UP; M8W1-UP)
• 972M Series XE (S/N: M5S1-UP; EDW1-UP)
• 980K (S/N: W7K1-UP; NEP1-UP; GTZ1-UP)
• 980M (S/N: MK21-UP; MGD1-UP; KRS1-UP; N8T1-UP)
• 982M (S/N: MK61-UP; F9A1-UP; LRS1-UP; K1Y1-UP)
» EARTHMOVING DIVISION » CONFIDENTIAL YELLOW 8 8
Quality Update – HVAC Control Panel
Issue
For certain machines using the 267-5243 control panel, the fan speed setting
may not functioning properly
Resolution
Solder is being added between the metal pathways for better connection
at the intersection of the printed circuit board.
1. If the fan speed setting is not functioning properly and the date
code is before 1638, replace the control panel.
2. If a fan speed setting is not functioning properly and the date
code is after 1638, then additional troubleshooting steps may be
required.
Resolution
The addition of a 524-2229 harness with relay will extend the
service life of the HVAC panel.
Disconnect main cab
harness (C) from
control panel, and
then install 524-2229.
Affected Models
• 120M (S/N: B9C739-807,1000-1443; R9C1-110; B9N347-354; B9W209-209; D9W195-
208,400-419,500-519)
• 120M Series 2 (S/N: M921-107; M9C1-791; M9H201-482; R9N102-218; R9W1-104,106-
197)
• 12M (S/N: B921-644; B9F1015-1121,1300-1497; B9R173-182,1388-1388)
Using two cable
• 12M Series 2 (S/N: F9B1-220; F9M1-481; R9P1-199; R9S1-360)
straps, secure relay
• 12M Series 3 (S/N: N9B1-101,103-488; N9F1-736; N9P1-229; N9R1-314)
• 140M (S/N: B9D3139-3329,3500-4959,76001-76001; D9G1158-1190,1300-1707)
tab (D) and relay (E) to
• 140M Series 2 (S/N: M9D207-310,500-1844; R9G1-372; M9J207-249,400-952; R9M1-559)
main harness bundle.
• 140M Series 3 (S/N: N9D1-848; N9G1-255; N9J1-570; N9M1-519)
• 14L (S/N: B941-188,191-204)
• 14M (S/N: R9J121-1857)
• 14M Series 3 (S/N: E9S1-206,250-257; N9S1-108,202-203,207-207,209-210,225-247)
• 160M (S/N: B9E523-570,700-1205; D9T165-182,300-311,1303-1520)
• 160M Series 2 (S/N: M9E206-213,400-409; M9K203-209,400-425; R9L1-258; R9T1-349)
• 160M Series 3 (S/N: N9E1-110; N9K1-127; N9L1-161; N9T1-236)
• 16M (S/N: R9H138-993)
• 16M Series 3 (S/N: E9Y1-206,225-245; N9Y1-108,201-203,207-209,225-231)
• 18M Series 3 (S/N: N9A1-228; E9W1-228)
• 24M (S/N: B931-206; B9K407-662,75001-75002)
» EARTHMOVING DIVISION » CONFIDENTIAL YELLOW 10 10
Quality Update – Blower Inlet Duct
Issue
The gasket can lose adhesion and be drawn into HVAC blower
inlet.
Resolution
An improved 525-4816 duct assembly for the HVAC is now
used on certain Motor Graders. The improved duct assembly
includes a flange for side support of gasket.
1. 249-0410 Gasket.
Affected Models 2. Fan housing
• 120M (S/N: R9A1-125; B9C512-1448; R9C1-110; B9N270-354; B9W188-209; D9W135-521) 3. 525-4816 Duct As
• 120M Series 2 (S/N: M921-107; M9C1-795; M9H201-488; R9N1-218; R9W1-197)
• 12M (S/N: B921-652; B9R159-1388)
• 12M Series 2 (S/N: F9B1-220; F9M1-481; R9P1-199; R9S1-360)
• 12M Series 3 (S/N: N9B1-449; N9F1-738; N9P1-233; N9R1-316)
• 12M Series II (S/N: R9R1-105)
• 140M (S/N: B9D2071-4963; B9G1001-1056; D9G1001-1714; B9M908-1078)
• 140M Series 2 (S/N: M9D1-1844; R9G1-372; M9J1-952; R9M1-558)
• 140M Series 3 (S/N: N9D1-856; N9G1-261; N9J1-582; N9M1-526)
• 14L (S/N: B941-204)
• 14M (S/N: B9J1063-1450; R9J1-1857)
• 160M (S/N: B9E388-1205; B9L478-505; B9T156-183; D9T121-1520)
• 160M Series 2 (S/N: M9E1-409; M9K1-425; R9L1-258; R9T1-349)
• 160M Series 3 (S/N: N9E1-110; N9K1-127; N9L1-167; N9T1-240)
• 16M (S/N: B9H707-866; R9H1-993)
• 16M Series 3 (S/N: E9Y1-247; N9Y1-231)
• 18M Series 3 (S/N: N9A1-228; E9W1-229)
Regulation:
– Paris agreement- Adopted by EU and
124 other countries including the US,
Canada, Australia
– Ratified Oct 2016 – EU
– Regulation (EU) No 517/2014
• The EU F-Gas Regulation will compel a
large-scale conversion to climate-
friendly technologies in new
equipment and products by 2030
• It will transform the European
economy with implications on
producers, importers, distributors,
manufacturers, operators, contractors
and consumers.
This chart is for EU only the other 124 countries have a different
methodology for implementation
1
7
System Design
• SAE J639 – Safety Standards for Motor Vehicle Refrigerant Compression Systems
• SAE J2772 – Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant
Leakage Conditions
• SAE J2773 – Standard for Refrigerant Risk Analysis for Mobile Air Conditioning Systems
• SAE J2842 – R-1234yf and R744 Design Criteria and Certification for OEM Mobile Air Conditioning Evaporator
and Service Replacements
Considerable effort required to develop internal specs and standards to address gaps!
R-1234yf R-1234yf
w/subcooler
Cab Temp compared to R-134a (°C)
Machine #1 - 1.5 Not Tested
Machine #2 0.1 - 0.4
Machine #2 (high ambient) 1.1 - 0.9
Machine #4 0.5 Not Tested
Sequence of Events
1. Compressor is seized resulting in slipping clutch
2. Heat generated on clutch surface increases coil
temperature
3. Thermal fuse reacts to excessive temperature – opens
circuit and deactivates clutch
4. Compressor pulley can rotate freely preventing further
catastrophic damage