Industrial Flowmeters

Pitot tube deltaflow -


an engineering approach

systec Controls Meß- und Regeltechnik GmbH


Thomas Gräber, Sales Manager
Industrial Flowmeters

Principles of dp-Measurement

- The sum of c kinetic + potential Energy is constant (= law of


conservation of energy)
- dp-measurement: transformation of potential energy
(pressure) into kinetic Energy (velocity)

EPot  EKin  const


Industrial Flowmeters

Principles of dp-Measurement
Industrial Flowmeters

Principles of dp-Measurement

 Orifice:
In the neck, velocity increases (kinetic E increases) and
pressure decreases (potential E decreases)
Industrial Flowmeters

Principles of dp-Measurement

Orifice

Nozzels

Venturi
Industrial Flowmeters

Principles of dp-Measurement

 Integrating pitot tube:


At the impact point of the probe, the velocity is zero (cinetic E
decreases) an the pressure raises (potential E increases)
Industrial Flowmeters

Principles of dp-Measurement

C  Flow Equation of
qm    d ² 2  dp   EN ISO 5167-1
1  4 4

pges dp

pstat

1 
qm    d ² 2  dp  
 4 Flow Equation of
deltaflow
Industrial Flowmeters

Principles of dp-Measurement

C  1 
qm    d ² 2  dp  qm    d ² 2  dp  
1  4 4  4

•C Flow factor, depending on dimensions and Reynolds


•ß Diameter ratio d/D
• blockage factor
• expansion factor (takes densitiy variations in account)
•dp differential pressure
• denistiy at working conditions
Industrial Flowmeters

Flow equation for liquids


C  1 
qm   d ² 2  dp  qm    d ² 2  dp  
1  4 4  4
When measuring liquids, the equation is less complicated:
•=1
•, C and  are almost constant qm  K dp
•ß, d and  are constant
mit
C 
K  d 2
2
1  4 4
bzw.
1 
K  d 2
2
 4
Industrial Flowmeters

The effect of C and 

C  1 
qm   d ² 2  dp   qm    d ² 2  dp  
1  4 4  4
C 1
The term 1   is similar to the deltaflow term
4

These are factors, which have been developed by
experiments
The blockage factor  is from Re=8000 constant
C is a function of Reynolds (Re) and depend on flow
exampel:
orifice; DN 200; ß=0,5 deltaflow, DN200
Re=100.000, C=0,6056 Re=100.000, =2,4093
Re=1.000.000, C=0,6032 Re=1.000.000, =2,4093
Error in C= 0,4% Error in  =0,0%
For big flow spans, the Re-impact on C must be compensated!
Industrial Flowmeters

The effect of 
C  1 
qm    d ² 2  dp   qm    d ² 2  dp  
1  4 4  4

Due to the pressure loss at the primary element, density of


compressible fluids change. That has an influence on the flow
measurement which is compensated by . For incompressible
fluids: =1

Exampel:
Air, 20°C, 1bar
Orifice; DN200; ß=0,6 deltaflow
200 Nm³/h =0,9999 =1,0000
2000 Nm³/h =0,9844 =0,9984
Change 1,55% 0,16%

For big flow spans, the impact of  must be compensated!


Industrial Flowmeters

Pressure loss of primary devices (see VDI/VDE 2040-1


Druckverlust [% von dp]
Bleibender Druckverlust [% von dp]
100% Blende
90% Düse
50%
80% Venturi
70% 40% deltaflow
60%
50% 30%
40%
30% 20%
20%
10%
10%
0% 0%
0,2 0,3 0,4 0,5 0,6 0,7 10 100 1000 10000
beta [-]
Durchmesser [mm]

High pressure steam example


ID 250, 185bar, 540°C, 550 t/h

deltaflow Venturi-nozzle orifice


beta 0,74 0,8
dp 2011 mbar 1998 mbar 3367 mbar
Pressure loss 169 mbar 299 mbar 1111 mbar
cost (3 cent /kWh) 12.349 EUR/p.a 21.849 EUR/p.a 81.187 EUR/p.a
Industrial Flowmeters

Energy savings by small pressure losses

deltaflow is only a small


restriction in the pipe!

Orifices create a
tremendus pressureloss
Industrial Flowmeters

Strength and weakness


Orifice Nozzel Venturi deltaflow
Price 3“ + O O O/+ (DF10M)
Price 8“ O - -- +
Price 20“ - -- -- ++
Price High Pres. Applications + O -- +
Installation costs - - - ++
Accuracy + O - +
Span - O O ++
Pressure loss -- - O ++
Dirty fluids -- - - ++
Small flow measurement ++ + + -
Influence of Expansion -- - O +
Influence of discharge - - + ++
coeffizient
Industrial Flowmeters

Flow optimised profile

Research co-operation with the University of Erlangen


Certificate by PTB (PTB is Germany's highest authority when it comes to
correct and reliable measurements. It is the supreme technical
authority of the Federal Ministry for Economic Affairs and Energy
Industrial Flowmeters

Flow optimised profile

High Flow Velocity Low Flow Velocity


1 
qm    d ² 2  dp  
 4
Blockage factor depends on Reynolds
(velocity)!

-> Traditional profiles: Drift


Industrial Flowmeters

Flow optimised profile

Speed-up curve -> defined


break-off point,
Smooth impact no drift

Sharp edges

The medium passes the smooth impact zone and speeds up


3 times it‘s velocity to the sharp edges. Result: defined separation point,
no drift

Result: accuracy <0,5% for Re>8000, drift-free,


tested by PTB
Industrial Flowmeters

Patented Manufacturing Process

1. welding -> Traditional manufacturing:


weak tolerances
2. milling +/- 0,5mm

3. grinding

Result: tolerance up to 1mm


1 
qm    d ² 2  dp  
 4
Blockage factor depends on width of probe
(a production tolerance of just 1mm at a pipe size of
100mm can cause a measurement error of 5% )
Industrial Flowmeters

Patented Manufacturing Process

deltaflow is robot welded in the uncritical speed up curves

tolerance: < 0,025mm!

 The width of the probe is well defined by the precision


rolling of the profile
Industrial Flowmeters

deltaflow: Advantages

 Patented flow profile – drift-free design


 Patented manufacturing process
 8mm dp tappings (Insensitive on dust)
 Kapillary free construcion (Free drain of condensate, gas bubbles)
 Integrated temperature- and pressure measurement possible
 Maintenance-free
 Low pressure loss (compared to classical dp-elements)
 Reduced installation time (up to 90% comp. to classical dp-el.)
 Flexible Configuration (1mm…15000mm, 690bar, >1000°C)
 low acquisition costs
Industrial Flowmeters

 deltaflow: Advantages

Narrowing orifice

Narrowing Venturi

Extreme less pressure


loss with deltaflow
Industrial Flowmeters

 deltaflow: Advantages

 Less pressure loss:

 orifice  deltaflow
180 bar/a 180 bar/a
550°C 550°C
76 kg/s 76 kg/s
DN 250 DN 250
orifice diameter 170mm
dp: 112,4 kPa dp: 41,48 kPa
pressure loss: pressure loss:
113,60 kPa 3,36 kPa
Industrial Flowmeters

 deltaflow: Advantages

 Less power loss


power loss = flow : density x pressure loss
Density: 53,48 kg/m3

 orifice  deltaflow
76 kg/s x 113,60 kPa 76 kg/s x 3,36 kPa
53,48 kg/m3 53,48 kg/m3
power loss: power loss:
161.43 kW 4,77 kW
Industrial Flowmeters

 deltaflow: Advantages

 Extrem energy saving

 Orifice  deltaflow

Annual energy costs: Annual energy costs:


161.4 kW x 8000h 4,77 kW x 8000h
= 1291.20 MWh = 38.16 MWh

Average annual energy saving: 1253 MWh


(80EUR/MWh = 100,243 EUR/a)

+ less operational demands of generators

+ less emission of CO2- lower costs (fees) for certificates


Industrial Flowmeters

deltaflow: Advantages
Shorter inlet requirements (1) -> less expenses for tubing

deltaflow can
already be mounted
after 7D
Industrial Flowmeters

deltaflow: Advantages

deltaflow:
ImproveIT data base
with calibration
factors (ca. 3000!)
for short inlets
Industrial Flowmeters

Straight run requirements


Industrial Flowmeters

Straight run requirements - ImproveIT


•ImproveIT is a data base which offers
calibration factors for typical obstacles
in inlet (curves)
• Factors are provided by systec on
request
• Factors can be put into deltacalc
Industrial Flowmeters

Design your deltaflow – deltaflow series

DF8 DF12 DF25 DF25HDD3 DF25 Quicklok DF44


Type Pipe Size Pressure Remarks

DF8 1-25mm 0-690bar Spool piece with integrated orifice

DF10 DN20-DN100 0-690bar Basically replaced by DF12

DF12 DN20-DN100 0-160bar


DF25 DN65-DN2500 0-PN160 (PN250)
DF25 Quick-lock DN65-DN2500 0-100bar Retractable

DF44 200mm-15m 0-100bar


DF25HDD3 60-690bar 0-690bar weld-in (high-pressure)
Industrial Flowmeters

Design your deltaflow – required parameters (1)


dp-connection
Stud (e.g. cut ring or flange)

Profile crosses whole diameter ->


length customized to application
Insulation IT • Internal Diameter ID
WT
• Wall thickness WT
• Thickness of isolation IT
ID
are required

Profile
Industrial Flowmeters

Design your deltaflow – required parameters (2)


Material Designation

1.4571 (SS316Ti) Stainless Steel, Standard


Material (>>90% of all
applications),
up to 500°C
1.4828 High-temperature
applications (up to 1040°C)
1.4539, Hastelloy corrosive media
C4, Haynes Alloy
High-pressue See seperate chapter

• In most cases neck and parts outside of the pipe can be made of
standard SS316 (1.4571) also when profile is made of special material
• Material of weld-in stud should be equal or similar to pipe material
Industrial Flowmeters

Calculate (design) your deltaflow – calculation software


deltacalc ? ..\..\..\..\..\Program Files (x86)\systec
Controls\DeltaCalc 8 Web\deltacalc8web.exe
Industrial Flowmeters

Design your deltaflow – Required dp


deltaflow requires a minimum differential pressure to ensure
reliable measurement:
As rule of thumb you should have at least:
• Gases / Liquids: >0.2mbar @ Qmin
• Steam: >5mbar (steam applications are more sensitive against
misinstallation than gas / liquids) @ Qmin
dp‘s can be calculated for each application by using deltacalc
software
Industrial Flowmeters

Mounting – Liquid Service

• Mounting should allow gas bubbles to vent off


• When installed sidewards probe should be slightly slanted
(-3…0°)
Industrial Flowmeters

Mounting – Gas Service

• Mounting should allow condensate to drain back into pipe


(Otherwise condensate might accumulate in internal piping
and generate water column (which generates faulty dp))
• When installed sidewards probe should be slightly slanted
(0..3°)
Industrial Flowmeters

Mounting – Steam Service

• Condensate is used to transmit dp to transmitter


• Mounting should allow excessive condensate to drain back
into pipe
• When installed sidewards probe should be slightly slanted
(0..3°)
Industrial Flowmeters

Mounting your deltaflow

Lower mounting times and costs (-90%)

Drilling installation hole 5 min


Welding in flange stud 20 min
Mounting deltaflow 10 min
Mounting manifold 5 min
Mounting dp transmitter 10 min
Wiring 10 min

Ready in 60 min !
Industrial Flowmeters

Design your deltaflow – required dp

How can I handle low flows?


• Sometimes velocity is too low to provide sufficient dp values
• Spool Pieces with reduction can be used to speed up media
Widening (e.g.
Reduction
DN65/DN100
(e.g. DN100/DN65)

By using spool pieces with


reduction deltaflow can serve also
typical low flow applications (e.g.
Biogas)
Industrial Flowmeters

Opposite Support - Background

 Probe has a specific resonance frequency


(RF) depending on length and width of probe
 Flow generates Vortex („turbulence“) with a
specific frequency (VF) at probe depending
on velocity and width of probe („probe is
stimulated“)
[RF and VF are mentioned at deltacalc calculation protocol]

 If Vortex frequency = resonance frequency


(or multiple) probe might resonate and might
break!

Vortex  To ensure mechanical stability an opposite


support might be required
Industrial Flowmeters

Frequency calculation without opposite support


Application: Steam, DN200, 7bar, 200°C, various flows, without opposite support
v=7.73m/s v=24.58m/s v=61.46m/s
RF VF SF VF SF VF SF
DF25 248.9 70,2 3,55 234,1 1,06 585,3 0,43

DF32 264.5 43,8 6,04 145,9 1,81 364,7 0,73

DF44 383.3 33,5 11,44 111,7 3,43 279,4 1,37

RF = Resonance Frequency of Probe / VF=Vortex Frequency


Saftey Factor SF = RF/VF
SF should be >= 1.3 to ensure mechanical stability
Industrial Flowmeters

Frequency calculation with opposite support

Application: Steam, DN200, 7bar, 200°C, various flows, with opposite support
v=7.73m/s v=24.58m/s v=61.46m/s
RF VF SF VF SF VF SF
DF25 995,8 70,2 14,19 234,1 4,25 585,3 1,7

DF32 1058,0 43,8 24,16 145,9 7,25 364,7 2,9

DF44 1535,2 33,5 45,83 111,7 13,74 279,4 5,49

Opposite Support quadruples Resonance Frequency and Saftey!


The bigger the profile the higher the resonance frequency
Industrial Flowmeters

Opposite Support – Examples

DF25 prepared for use with (upper) and


without (lower) opposite support
High-pressure probe with
opposite support
Industrial Flowmeters

Opposite Support – Summary / Design Rules

Opposite Support Required if:


• Pipe Size >= DN1000
• dp >= 20mbar and RF/VF <= 1.3
• High-pressure probe

Check (if required or not) is done automatically by deltacalc (except


because of size!)
Industrial Flowmeters

Integrated pressure/temperature measurement - background

1 
qm    d ² 2  dp   Density, depends on
 4 pressure (p) and
Temperature (T)

• If pressure and/or temperature change, density also changes


• Density influences flow (e.g. T +10% -> density +10% -> q +srt(10%)=3.16%
• To compensate influence, p and/or T should be measured in order to calculate
correct density (flowcom / multi variable transmitter)
• Only recommended/required when p and/or T fluctuate
Industrial Flowmeters

Flowcomputer flowcom

• p&T compensation + Mass flow calculation


• Heat transfer measurement
• Data Logger + Display
• Easy handling (on-site with buttons)
Industrial Flowmeters

Integrated pressure/temperature measurement

Cable Box

Integrated PT100

Presseure measurement
(here: Steam Service)

- Can be removed under pressurized - Can be removed under pressurized


conditions Conditions (when having valve)
- 0…400 (600°C) - direct PT100 or 4…20mA
- direct PT100 or 4…20mA (with transmitter)
Industrial Flowmeters

Integrated pressure/temperature measurement - Examples

DF44 with preparation for external


pressure transmitter (supplied by DF12 with spool piece, integrated
customer) temperature measurement
(here: Liquid Service) (Gas Service)
Industrial Flowmeters

Integrated pressure/temperature measurement - Examples

DF10 with integrated DF8 with preparation for DF8 with preparation for
temperature (Gas Service) pressure measurement pressure measurement
(Gas Service) (Steam Service)
Industrial Flowmeters

Integrated pressure/temperature measurement

Model Integrated Integrated


pressure Temperature
DF8 X X Integrated in
spool piece
DF10 X X Integrated in
spool piece
DF12 (x) (x) Only with
spool piece
DF25 X X
DF25HDD3
DF44 X X
Industrial Flowmeters

dp-Connection - 3-way-manifold

direct
+ Easy setting of zero point by using by-pass
+ Shut-off of media (e.g. allows remove of transmitter)
+ high pressure / temperature (PN400)
- Smaller internal piping -> not recommended for wet gases
Industrial Flowmeters

Design your deltaflow - Mounting of dp-transmitter

Direct Mounting Remote Mounting


Industrial Flowmeters

Splitting Range Measurement


How can I handle big measurement ranges?
• deltaflow offers a span of typically 1 to ……
• 1 to 10 in flow means 1 to 100 (!) in dp
How does that influence my measurement?
Example:
dp_min = 2mbar / dp_max = 240mbar
span dp-transmitter: 250mbar, uncertainty 0.1% (=0.25mbar)
0.25mbar at 2mbar means relative uncertainty of 12.5%
With splitting range. e.g:
1. Transmitter: 0…20mbar
2. Transmitter: 20…240mbar
Industrial Flowmeters

Design your deltaflow – splitting range

How can I realize a splitting range measurement?

• You need two (or more) (stacked) transmitters


• You need evaluation unit (e.g. flowcom or PCS)
which decides which transmitter should be used
(depending on dp)

Connectors („T-bone“)
Industrial Flowmeters

Splitting range - summary

• With splitting range up to 4 dp-transmitters can be used


• Span of 1..30 and more can be realized
(pay attention to mechanical stability)
Industrial Flowmeters

Air purging system LSP

• Highly Polluted media might clog deltaflow‘s dp-tappings


• When dust-load >=50mg/m3 automatical cleaning is
required
• systec offers automatic air purging system LSP for
periodical cleaning
• LSP blows pressurized air into deltaflow pressure
chambers
Industrial Flowmeters

Air purging system LSP - Principle


dp-transmitter can be mounted
Valves: When purging
directly on LSP by using
connection to dp-
mounting plate
transmitter is closed and
connection to pressurized
air is open

Connections
for dp-impulse
pipes (Ermeto, Purging is controlled by SPS.
others on Frequency of purging as well as
request) length of purging can be set by
Connection for user
pressurized air
(max. 6bar)
Industrial Flowmeters

Air purging system LSP - Example

deltaflow DF50 (old


style), flange type

Shut-off (ball valves)

LSP with mounted dp- Connected by impulse


transmitter piping
Industrial Flowmeters

Air purging system LSP - Summary

• With LSP measurements at high degrees of pollution (up to


200 g/m3 (!)) become possible
• During purging dp is hydraulically locked -> no lost of dp-
signal during purging
• Option „Signal holding“ available. Here, last value of dp
before purging is holded electronically by SPS
• Direct mounting of dp-transmitter possible (on top of LSP)
• Pressurized Air required on site (max. 6 bar)
• Impulse piping required (LSP - deltaflow)
Industrial Flowmeters

High pressure probe


When do I need high pressure probe?

• Limits for standard DF25: PN160 (steam), PN250 (Liquids)


Finally, it has to be determined by customer, but there are
indications when to use high-pressure probe:
• When weld-in probe is required (e.g. sealings are not
accepted)
• When pipe is made of high grade material (e.g. P91, 10CrMo
9 10))
Industrial Flowmeters

High pressure probe


For high pressure applications a special version of the DF25
(DF25HDD3) is available
Condensate Pots • Profile made of massive block (no
(for steam only) welding seams)
Weld-in part
(„neck) • Material of Profile: 1.4828
• Materials of weld-in parts:
Double valves 16Mo3, 10CrMo 9 10, P91
Profile • Material of valves:
16Mo3, 10CrMo 9 10
• opposite support always required
Industrial Flowmeters

High pressure probe - Examples

- Steam, 540°C, 100bar


- Profile: 1.4828
- Steam, 535°C, 190bar - Weld-in part: 10 CrMo9 10
- spool piece - Condensate Pots:
- Profile: 1.4828 10 CroMo 9 10 (=1.7380)
- Weld-in part: P91
- Condensate Pots: P91
Industrial Flowmeters

High pressure probe – Required certificates / testings


Requirements are regulated by PED97/23/EG
16 Mo 3 13CroMo44 10CrMo9 10 X20CrMoV12 1 P91
(1.5415) (1.7335) (1.7380/1.7383) (1.4922) (1.4903)

X-Ray X

TÜV acceptance x x x x X
test (dye penetration,
hardness test, material
identification check)

Heat x x x x
treatment

Documentation incl. x x x x x
3.2 certificate
Industrial Flowmeters

Calibration

1  Formula for flow calculation


qm    d ² 2  dp  
 4
• During calibration flow, dp (at deltaflow), p, T are measured at
different points
• Corrected Blockage Factor Zeta is extracted
• Corrected Zeta will be then used for your appliaction
-> Improved accuracy (0.4%)
• Calibration can be done at PtB or at systec
• Spool Piece always required
• PtB or systec issue calibration certificate
Industrial Flowmeters

Factory Certificate PtB Certificate


Industrial Flowmeters

weld-in stud with Quicklock with Quicklock with


DIN/ANSI flange chain (max PN16) - spindle (max
retractable PN100) -
retractable

weld-in stud (max


PN40)
Industrial Flowmeters

-½” NPT female oval flanges DIN ball valve R ½”


EN 61518

oval flanges on ball


three way manifold
valve shut off valve
on oval flanges
welding ends, SS
Industrial Flowmeters

Design your deltaflow – deltaflow types

Flange-type

Cut-Ring Type
Industrial Flowmeters

Design your deltaflow – deltaflow types

Spool Piece Weld-in (DF25HDD3) Weld-in (DF12)


Industrial Flowmeters

Design your deltaflow – deltaflow types

DF8 – spool piece (block) with


integrated orifice
DF25 Quick-lock system allows
mounting/extraction under
pressurized conditions (max.
100bar)
Industrial Flowmeters

deltaflow types - Summary

DF8 DF12 DF25 DF25 DF44 Remarks


HDD3
Flange-stud X X X Max. PN250
(PN160 for steam)

Cut-Ring X X Max. PN40


Weld-in X X
Quick-lock o.r. X Max. 100bar
Spool Piece X X X X max DN250 (other o.r.)

Note: Spool Pieces are available with welding ends or flanges


Industrial Flowmeters

dp-Connection – Miscellaneous
Fitting (e.g. Ermeto) Welding Ends for
for remote mounting remote mounting

Ball Valve with fitting (e.g. Oval Adapter (direct mounting)


Ermeto) for remote mounting (acc. to EN61518)
Industrial Flowmeters

dp-Connection – Miscellaneous (2)

Weather Protection Box


+ provides heating and protection for electrical equipment (transmitters)
+ Can be mounted remotley or direct on deltaflow‘s flange
Industrial Flowmeters

• deltaflow vs. Vortex

+ Large span (nominell 1…30/40)


+ compact
+ price (DN100, ca. 1400-2000€)
+ accuracy (like deltaflow)

- Max. DN250-DN400, max. 250°C-400°C, max. 100 bar (typical)


- spool piece required (cut-off of pipe -> mounting costs)
- High-pressure loss -> real span comparable to deltaflow
- Long straight run required (min. 20xD)
- very sensitive (twice as deltaflow) against p/T fluctuations
(when not compensated)
Industrial Flowmeters

• deltaflow vs. magnetic-inductive flowmeter

+ price (DN300, ca. 2500€)


+ accuracy (0.5% (cutting-edge meters)

- Expensive @ big diameters


- Only liquids can be measured
- Liquid must be electrically conductible
- e.g. works not for desalinated water (cooling water)
- Not recommended for hot-water
(disposal of magnetite at electrodes -> drift)
Industrial Flowmeters

• deltaflow vs. thermal mass flow

+ big span (1…100)


+ suited for low flow
+ gives mass flow
+ cheap (starts at 200€ for low quality)

- Decreasing accuracy at higher velocities


- Sensitive / highly sensitive (low cost) against condensate, (oil) films
- Single point measurement (deltaflow: averaging)
- Limited accuracy (2% for cutting-edge meters
typical 10% for low cost.
Industrial Flowmeters

• deltaflow vs. mechanical flowmeters

+ cheap (starts at 300€)


+ integrated flow indicator

- Expensive at large diameters (typical limited to DN200)


- Limited accuracy (5% of FS, most of cases worse)
- moving mechanical parts subject to wear and tear
- risk of drift caused by wear and tear (e.g. of bearings)
- More an indication than measurement
- Mounting costs: Rip up of pipe required
Industrial Flowmeters

deltaflow vs. classical dp-elements (orifice)

+ cheap (orifice itself)


+ standardize (EN DIN5167)
+ widespread, accepted
+ self-made by some engineering companies

- Expensive @ big diameters


- High mounting cots (rip-up of pipe required
- High pressure lost (see example below)
-Long straight runs required (min. 15xD)
High operational costs (energy loss) [calculation with systec
spread-sheet possible)
Industrial Flowmeters

Example 1:

Powerplant

deltaflow for steam with integrated p&T measurement


Industrial Flowmeters

Example 1:
Powerplant

deltaflow for steam


material P91
Pressure 285 bar/ü
Temperature 565 °C
Industrial Flowmeters

Under Pressure

deltaflow for natural gas


PN320, 100% Humidity,
protection box, Ex
Industrial Flowmeters

Small Pipes

deltaflow DF8 for steam


Industrial Flowmeters

Chemistry

deltaflow for process gas, Bayer AG, Hastelloy


C4, 180°C, HCl, Ex
Industrial Flowmeters

Waste Water Plants

deltaflow for Biogas


Industrial Flowmeters

Car manufacturers (and others)


deltaflow for compressed air, integrated p&T-measurement,
Daimler-Chrysler
Industrial Flowmeters

Oil & Gas Industry

deltaflow for natural gas, PN160, integrated p- and T-


measurement, protection box, ex
Industrial Flowmeters

Geothermal Power Plant (near Munich)

2 crossed deltaflows in spool piece (calibrated)


Industrial Flowmeters

Under Pressure

deltaflow for natural gas


PN320, 100% Humidity,
protection box, Ex
Industrial Flowmeters

Chemistry

deltaflow for process gas, Bayer AG, Hastelloy


C4, 180°C, HCl, Ex
Industrial Flowmeters

Emission Monitoring

deltaflow for chimney, including. P, T, dp and flowcom


in protection box
Industrial Flowmeters

Municipalities

deltaflow for hot water, bi-directional, splitting range


Heat transfer measurement
Industrial Flowmeters

Extraction systems

- Allows installation / extraction under pressure


- Rated up to 100 bar
Industrial Flowmeters

Thank you for your attention