Highlights

• Single phase or Three phase


• Accuracy Classes: 0.2, 0.1, 0.05 (C/B/A)
• Electricity Meter On Site Testing
• Voltage Measurement up to 500V
• Direct Current Sensor up to 20A
• Current Clamp Type Sensors up to 120 A
or 240 A
• Flexible Current Probe up to 6000 A
• Integrated Error Calculator
• Snap Switch, Impulse Input
• Measured quantities
– power and energy - active, reactive,
apparent
– voltage, current, phase, frequency,
distortion, harmonic content
• Rechargeable batteries
Applied Precision Ltd. www.appliedp.com 2
Highlights

• Color graphic display and alphanumerical


keypad
• Vector diagram and signal shape display
(oscilloscope mode)
• Harmonics analysis in graphical format
• Synchronous differential energy
consumption measurement
• Optional wireless communication interface
and wireless scanning head network for
simultaneous testing of multiple delivery
nodes
• Configuration and data stored in high
capacity memory (min. 2 GB)
• Enhanced internal database system for
tested meters and measured results with
search capabilities

Applied Precision Ltd. www.appliedp.com 3


Highlights

• Lightweight compact size


• Two universal input channels for any
combination of Voltage and Current
probes for Power or CT / VT ratio
measurement
• Push-pull system for connecting-
disconnecting accessories and probes

• USB, RS-232 and optical interface for


local data exchange with multifunctional
meters according to IEC 62056-21

Applied Precision Ltd. www.appliedp.com 4


Highlights

• Transport case with high protection degree


• Enhanced self-adjusting optical scanning
head
• LED and TTL impulse outputs with
programmable energy proportional meter
constant or programmable frequency
• PC software for MS Windows
• Optional portable printer for printing of
results and actual display content
• Configurable user interface
(regional and functional modifications)

Applied Precision Ltd. www.appliedp.com 5


Voltage Measurement

• Voltage Transducer VT 2x50B


• Voltage Range: 0.1V – 500V
• Basic Error:
0.05% with WS 2x20A
0.1% with WS 2x20B
0.2% with WS 2x20C
• Standard accessories

Applied Precision Ltd. www.appliedp.com 6


Current Measurement – CC 2x12B

• Current Clamps CC 2x12B


• Current Range: 1mA – 120A
• Basic Error:
0.1%, 0.1° with WS 2x20B or WS 2x20A
0.2%, 0.2° with WS 2x20C
• Compensated clamps
• Max. cable size: ∅12mm
• Standard accessories

Applied Precision Ltd. www.appliedp.com 7


Current Measurement – CC 3x24C

• Current Clamps CC 3x24C


• Current Range: 1mA – 240A
• Basic Error:
0.2%, 0.2° with WS 2x20B or WS 2x20A
0.3%, 0.3° with WS 2x20C
• Compensated clamps
• Max. cable size: ∅20mm
• Optional accessories

Applied Precision Ltd. www.appliedp.com 8


Current Measurement – CT 2x20

• Current Transducer CT 2x20


• Current Range: 1mA – 20A
• Basic Error:
0.05%, 0.05° with WS 2x20A
0.1%, 0.1° with WS 2x20B
0.2%, 0.2° with WS 2x20C
• Direct current input
• Optional accessories

Applied Precision Ltd. www.appliedp.com 9


Current Measurement – FCP 3x10

• Flexible Current Probe FCP 3310C


• Current Range: 0.2A – 6000A
• Basic Error:
0.2%, 0.2° with WS 2x20B or WS 2x20A
0.3%, 0.3° with WS 2x20C
• Optional accessories

• Flexible Current Probe FCP 3310D


• Current Range: 0.2A – 6000A
• Basic Error:
0.5%, 0.3° with WS 2x20B or WS 2x20A
0.6%, 0.4° with WS 2x20C
• Optional accessories

Applied Precision Ltd. www.appliedp.com 10


Optical Sensor – OPTS 2100

• Sensing LED, Disk or LCD segment of


tested meter
• Self-calibration function
• Indication LEDs
• Mark
• Info
• Error

• Fixing Clamp for attaching the Optical


Sensor to any type of tested meter
• Standard accessories

Applied Precision Ltd. www.appliedp.com 11


Impulse Input / Snap Switch

• Impulse Input Base


• Impulse Input cable for sensing the meter
impulse output
• Snap Switch for manual capturing of meter
mark
• Standard accessories

Applied Precision Ltd. www.appliedp.com 12


Portable Printer

• Enables to print meter test report on site


HEADER
• Interconnected with WS via RS-232 cable DATE: 15.02.2009
SNUM: 1315050166
• Powered by rechargeable batteries TYPE: ET 420
YMAN: 1998
• Optional accessories VOLTAGE: 3 x 230/400V
CURRENT: 10-40A
CONSTANT: 375r/kWh
CLASS: 2 %
CUSTOMER: Applied Precision
ADDRES: Stavitelska 1, Bratislava
NOTE1: Note 1
NOTE2: Note 2
NOTE3: Note 3
NOTE4: Note 4

LOADPOINT 1
U[V] 230.02 229.48 229.92
I[A] 120.09 120.20 120.01
P[W] 13855.27 13855.27 13855.27
Q[var] 23873.34 23816.44 23874.72
S[VA] 27599.07 27606.00 27581.49
PF 0.50 0.50 0.50
Phi 59.86 59.62 59.94
f[Hz] 50.00
Error[%] 0.327
St.Dev[%] 0.003

Applied Precision Ltd. www.appliedp.com 13


Other accessories

• Car Outlet Adapter (12V)


• Standard accessories

• Impulse Output Cable with BNC


connector
• User programmable output frequency
proportional to measured active,
reactive or apparent power
• Standard accessories

Applied Precision Ltd. www.appliedp.com 14


Measurement – Basic Screens

Applied Precision Ltd. www.appliedp.com 15


Meter Testing

/AME5AMK 64E‐CRG     
031109130243)(00)
(AMT B0B‐FA4TR)
(01010101B10100)
C.1.0(00004562)
1.8.0(002400.8*kWh)
1.8.1(000000.0*kWh)
1.8.2(002400.8*kWh)
1.8.3(000000.0*kWh)
1.8.4(000000.0*kWh)
0.1.2(01‐11‐09 00:00:00)
1.8.0*1(002400.8*kWh)
1.8.2*1(002400.8*kWh)
1.8.3*1(000000.0*kWh)

Applied Precision Ltd. www.appliedp.com 16


Transformer Test

Applied Precision Ltd. www.appliedp.com 17


Database of Meters

Applied Precision Ltd. www.appliedp.com 18


Control Software

• Data readout from Working


Standard
• Data archiving to archive
database
• Data viewing, sorting and
filtering
• Output protocol printing