SAUDI ARAMCO INSPECTION CHECKLIST
Receiving Insp of Industrial Boilers & Mech. Components SAIC-F-2021 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR
EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
A. Document Verification
Final Disposition Report was reviewed by the Contractor and Schedule "Q",
A1 submitted to Saudi Aramco within two weeks of acceptance of Att. III, Para.
material or equipment. 3.24
Boiler Manufacturer shall prepare & submit for approval & review 32-SAMSS-021,
A3
preliminary & certified drawings & data from Form NMR-7913. Para. 26.1
Bearings and seal assemblies are fully protected against the entry of 32-SAMSS-021,
A8
moisture and dirt. Para. 25.1.7
Flanges are fitted with a steel or wood cover, 3 mm thick and 32-SAMSS-021,
A10
neoprene gaskets. Para. 25.1.8
32-SAMSS-021,
A11 Threaded connections are protected with threaded plugs.
Para. 25.1.12
Boilers manufactured both in Saudi Arabia and outside Saudi Arabia 32-SAMSS-021,
B1
is Code stamped. Para. 24.1
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
D Internal Protection:
Drums and headers have been sealed vapor tight, using metallic 32-SAMSS-021,
D2
covers for inhibitors to be effective. Para. 25.2.2
Air cooled heat exchanger has no visible damage to the shell, fans or Schedule "Q",
E1
its appurtenances. Att IV, Para. 5
All outside water walls and furnace division walls shall be of the 32-SAMSS-021,
F1
membrane wll design. Para. 7.1.13
Gaps between tubes shall be proportional to the tube OD, and shall 32-SAMSS-021,
F3
not exceed 25 mm. Fins shall be at least 6.00 mm thick. Para. 7.1.14
All water, steam & fuel piping shall extend 1.0 m beyond the battery 32-SAMSS-021,
F4
limits of the boiler, exact locations specified by the Design Engineer. Para. 7.1.15
32-SAMSS-021,
F6 The boiler floor casing shall be a minimum of 1 m above grade.
Para. 7.1.16
Facilities shall be provided for the complete draining of all water from
the fire side of boiler units after washing. Drains openings shall be a 32-SAMSS-021,
F8
minimum of 75 mm diameter and be sealed against overheating and Para. 7.1.18
escape of flue gases.
The number, size, and location of ports shall ensure the visibility of all
32-SAMSS-021,
F10 burner tips, furnace rear walls, side walls, furnace exit areas, and
Para. 7.3.4
furnace roofs.
G Superheaters
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
32-SAMSS-021,
G1 Superheater headers and supports are located outside gas spaces.
Para. 7.4.6
32-SAMSS-021,
G2 All headers shall be provided with drain and vent connections.
Para. 7.4.6
The outlet header shall be provided with connections for safety 32-SAMSS-021,
G4
valves and startup vent. Para. 7.4.6
All outlet header connections shall be located upstream of the startup 32-SAMSS-021,
G5
vent. Para. 7.4.6
H Desuperheaters
32-SAMSS-021,
H1 Desuperheaters shall be of the water-spray design.
Para. 7.5.1
All tubes shall be seamless steel or electric resistance welded (ERW) 32-SAMSS-021,
I1
steel. ERW tubes shall not be used in superheaters. Para. 7.6.1
32-SAMSS-021,
I2 All tubes shall have a minimum outside diameter of 38 mm.
Para. 7.6.2
The minimum wall thicknesses of tubes shall be: 4 mm for 3" OD 32-SAMSS-021,
I4
tubes and 3 mm for 2"OD tubes and below. Para. 7.6.7
Horizontal (less than 3 degrees) tubes located in furnace floors shall 32-SAMSS-021,
I6
be covered by firebricks, 50 mm minimum thickness. Para. 7.6.9
A manway shall be provided at both ends of steam and water drums 32-SAMSS-021,
J3
and provided with hinged covers. Para. 7.8.8
32-SAMSS-021,
J4 Header handholes shall be provided.
Para. 7.8.9
32-SAMSS-021,
J5 The facings of flanged connections shall be raised face type.
Para. 7.8.11
Steam and water drums shall be welded, postweld heat treated, and 32-SAMSS-021,
J6
100% radiographically tested in accordance with the Code. Para. 7.8.12
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Separate drain valves shall be provided at the lowest point of water 32-SAMSS-021,
L2
drums as a means for the draining of boilers. Para. 7.10.2
M Casing
Access doors shall be easy to enter from floor levels or platforms, 32-SAMSS-021,
M3
and shall be clear of all obstructions. Para. 7.11.3
N Structural Steel
Burner platforms shall be provided with at least one stairway and 32-SAMSS-021,
N2
have access to all other platforms. Para. 7.12.9
Where several levels of burners are installed, each level shall be 32-SAMSS-021,
N4
provided with a separate platform & minimum headroom of 2.1 m. Para. 7.12.11
O Valves
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
All fuel shutoff valves shall be slow-opening, quick-closing, tight shut- 32-SAMSS-021,
O1
off valves, and shall be certified fire-safe. Para. 7.14.2
Fuel gas and fuel oil shut-off valves shall be either ball or non- 32-SAMSS-021,
O2
lubricated plug types. Para. 7.14.3
Position indicator handles shall be supplied for all ball and plug type 32-SAMSS-021,
O3
valves. Para. 7.14.4
P Sootblower
Drain valves shall be interlocked with the control valve to ensure that
32-SAMSS-021,
P5 upstream condensate is drained during warm-up and prior to the
Para. 8.2.2
operation of sootblowers.
Q Air Pre-heaters
Economizers shall be designed for upward water flow. Water outlet 32-SAMSS-021,
R1
connections shall be located below the LLCO of the steam drum Para. 10.1.1
32-SAMSS-021,
R2 Economizer shall be provided with a block valve and a safety valve.
Para. 10.1.4
Finned tubes, with a maximum of six fins per 25 mm, shall be used.
The fins shall be attached by high-frequency continuous resistance 32-SAMSS-021,
R3
welding. The fin thickness shall be a minimum of 1.25 mm and the fin Para. 10.2.2
height shall not exceed 25 mm.
Oil gun assemblies shall be provided with flexible stainless steel 32-SAMSS-021,
S6
hoses for fuel oil and atomizing steam. Para. 11.2.5
Air diffusers located at the ends of burner positioning tubes shall be 32-SAMSS-021,
S7
fabricated from heat-resistant alloy. Para. 11.2.6
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
All parts of air registers shall be shielded from furnace radiation and 32-SAMSS-021,
S11
protected against conducted heat as covered in NFPA 85. Para. 11.4.2
Burner shall be furnished with windboxes, with bolted access doors, 32-SAMSS-021,
S13
and acoustic insulation where required. Para. 11.6.1
Windboxes shall have dampers & guide vanes to assure equal 32-SAMSS-021,
S14
distribution of combustion air to air registers for each burner. Para. 11.6.2
32-SAMSS-021,
S15 Tie-ins for burner piping shall be from the top of headers.
Para. 11.7.2
32-SAMSS-021,
S16 Fuel headers shall be supplied with blow-down connections.
Para. 11.7.3
All piping and valving shall be located, from a single-point entry, for 32-SAMSS-021,
S17
each fuel to the burner assembly. Para. 11.7.4
Hoses are used only for atomizing steam & liquid fuels heavier than
68° API, (0.709 relative density). Design & materials shall be:
1) Three ply construction comprising of the following:
a) An inner hose of close pitch corrugated Monel tubing
32-SAMSS-021,
S19 b) A middle layer of type 321 stainless steel braid
Para. 11.7.7
c) An outer layer of interlocked galvanized steel armor
2) Either weld-end or flanged connections
3) Hoses are installed so the manufacturer's minimum bend radius is
not exceeded, or any moment is applied while in service
Fans shall be heavy duty, low speed types connected to drivers by 32-SAMSS-021,
T1
flexible couplings with coupling guards. Para. 12.1.1
32-SAMSS-021,
T4 Fan housings shall be a minimum of 5 mm thick.
Para. 12.2.5
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Air intakes of fans located outdoors shall be provided with bird 32-SAMSS-021,
T8
screens & with means to avoid pickup of rain & wind-driven sand. Para. 12.2.7
Air intake and discharge ducts shall be provided with silencers in 32-SAMSS-021,
T9
order to meet the noise level limitations specified. Para. 12.2.8
32-SAMSS-021,
T10 Turbine drivers shall conform with requirements of 32-SAMSS-009.
Para. 12.3.2
32-SAMSS-021,
T11 Motor drivers shall conform with requirements of 17-SAMSS-503
Para. 12.3.3
Y Ductwork
The Boiler Manufacturer has furnish a complete ductwork system for 32-SAMSS-021,
U1
combustion air travel from air intake fans to burner windboxes. Para. 13.1.1
Flue gas ducting from the outlet to the stack, with all the necessary
32-SAMSS-021,
U3 appurtenances, shall be furnished by the Boiler supplier when
Para. 13.1.3
specified on the data sheet.
Ducts shall be airtight and gastight. The maximum velocity of air and 32-SAMSS-021,
U4
flue gas shall not exceed 20.0 m/s. Para. 13.2.2
The minimum thickness of flue gas ducts shall be 5 mm and air ducts 32-SAMSS-021,
U6
shall be 5 mm minimum thickness. Para. 13.2.4
Casing and Duct Leakage Testing : A smoke test or soap test at the
32-SAMSS-021,
U11 forced draft (FD) fan shutoff pressure shall be performed onsite to
Para. 23.1
check for casing and ducting leakage.
V Stacks
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Clips or welding studs for holding wires and bands shall be spaced a 32-SAMSS-021,
W4
maximum of 450 mm on center. Para. 15.2.2
Exposed supports, duct doors, and other parts that project through 32-SAMSS-021,
W5
insulated surfaces shall be insulated for protection of personnel. Para. 15.2.2
A sealing air system shall be provided from forced draft fan discharge
ducts for all burner removal openings, sootblower wall boxes, and
32-SAMSS-021,
X6 observation ports. Flexible connections between the sealing system
Para. 17.1.7
and air supply lines may be used to compensate for differential
expansion.
Safety valves for drums, superheater outlets, & economizers per the
requirements of Code and 34-SAMSS-611. Valves shall be complete 32-SAMSS-021,
Y1
with discharge piping to a point 3 m above the nearest platform. Para. 17.2 (1)
Safety valves shall be equipped with lifting levers.
32-SAMSS-021,
Y4 Boiler feedwater shutoff and check valves.
Para. 17.2 (4)
32-SAMSS-021,
Y5 Boiler vent valves, using two valves in series at each location.
Para. 17.2 (5)
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Chemical feed valves, using two block valves in series and a check 32-SAMSS-021,
Y8
valve. Para. 17.2 (8)
Superheater drain and vent valves, using two valves in series at each 32-SAMSS-021,
Y9
location. Para. 17.2 (9)
Lower header drain valves, using two valves in series for each 32-SAMSS-021,
Y10
connection. Para. 17.2 (10)
32-SAMSS-021,
Y12 Lower drum drain valves, using two valves in series at each location.
Para. 17.2 (12)
Three sample coolers (in accordance with ASTM D1066), each with a
rack, valving and drainage trough. The sample piping and valving 32-SAMSS-021,
Y13
shall be arranged such that boiler water, saturated steam, and final Para. 17.2 (13)
steam each have a dedicated cooler.
32-SAMSS-021,
Y14 Desuperheater water shutoff and check valves.
Para. 17.2 (14)
32-SAMSS-021,
Y15 Sootblower steam valves, using two valves in series at each location
Para. 17.2 (15)
Economizer outlet stop valve and screwdown nonreturn valve, where 32-SAMSS-021,
Y16
a water bypass is included Para. 17.2 (16)
Economizer safety valve (in accordance with the Code) if a bypass is 32-SAMSS-021,
Y18
included. Para. 17.2 (17)
32-SAMSS-021,
Z3 Connections for flame monitoring and scanning
Para. 17.4.1 (3)
Connections for draft gages at fan inlet and discharge, air outlet of
32-SAMSS-021,
Z5 the air preheater, windbox, furnace, boiler outlet, economizer outlet,
Para. 17.4.1 (5)
flue gas outlet of the air preheater, and stack entry.
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
AA PAINTING
32-SAMSS-021,
AA2 Gasket contact surfaces shall not be painted.
Para. 19.2
AB Fabricated Items:
AC P&ID Walkthrough
REMARKS:
REFERENCE DOCUMENTS:
1. 32-SAMSS-021, Manufacture of Industrial Boilers, (12 January 2013)
2. Schedule Q, Contractor's Quality Requirements, (Project Specific)