You are on page 1of 4

SAUDI ARAMCO ID/PIEU - 30-Apr-2017 - REV. 2015.03.00 (Standards Cutoff - March 2015) Rev. 2015.03.

00 31-Mar-15
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Receiving Inspection of Power Piping & Auxillaries SAIC-F-2022 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A. General:

Damage was avoided during shipment, to all instruments and valves, 32-SAMSS-021,
A1
including auxiliary systems. Para. 25.1.5

All exposed finished and machined surfaces, including bolts, are 32-SAMSS-021,
A2
coated with a rust-inhibiting compound. Para. 25.1.6

Bearings and seal assemblies are fully protected against the entry of 32-SAMSS-021,
A3
moisture and dirt. Para. 25.1.7

Flanged connections and all other machined surfaces are protected 32-SAMSS-021,
A4
by a coating, such as MIL-C-16173 Grade IV. Para. 25.1.8

Flanges are fitted with a steel or wood cover, 3 mm thick and 32-SAMSS-021,
A5
neoprene gaskets. Para. 25.1.8
32-SAMSS-021,
A6 Threaded connections are protected with threaded plugs.
Para. 25.1.12

B. Improper practices or careless handling are likely to result in pipe damage of the following types:

Dents or ovalness of the pipe due to improper supports, or too widely 01-SAMSS-024,
B1
spaced supports and excessive stacking height. Para. 4.3
End damage due to use of improper end hooks for lifting or due to
improper nesting or denesting techniques, or due to longitudinal 01-SAMSS-024,
B2
shifting of the pipe and striking the end of the pipe, which would Para. 4.3
cause cutting of the bevel.
Fatigue cracks due to excessive static and cyclic loads as a result of 01-SAMSS-024,
B3
vertical vibrations during transportation. Para. 4.3
Abrasion or peening due to rubbing or striking of the pipewall against 01-SAMSS-024,
B4
other objects. Para. 4.3
REMARKS:

REFERENCE DOCUMENTS:
1. 32-SAMSS-021, Manufacture of Industrial Boilers, (28 January, 2003)
2. 01-SAMSS-024, Pipe Handling and Nesting, (29 October, 2003)

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others

Saudi Aramco: Company General Use


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 30-Apr-2017 - REV. 2015.03.00 (Standards Cutoff - March 2015) Rev. 2015.03.00 31-Mar-15
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Receiving Inspection of Power Piping & Auxillaries SAIC-F-2022 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME

SAUDI ARAMCO USE ONLY


SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A General:

Damage was avoided during shipment, to all instruments and valves, 32-SAMSS-021,
A1
including auxiliary systems. Para. 25.1.5

All exposed finished and machined surfaces, including bolts, are 32-SAMSS-021,
A2
coated with a rust-inhibiting compound. Para. 25.1.6

Bearings and seal assemblies are fully protected against the entry of 32-SAMSS-021,
A3
moisture and dirt. Para. 25.1.7

Flanged connections and all other machined surfaces are protected 32-SAMSS-021,
A4
by a coating, such as MIL-C-16173 Grade IV. Para. 25.1.8

Flanges are fitted with a steel or wood cover, 3 mm thick and 32-SAMSS-021,
A5
neoprene gaskets. Para. 25.1.8

32-SAMSS-021,
A6 Threaded connections are protected with threaded plugs.
Para. 25.1.12

No Dents or out-of-round pipe was found, due to improper support, or 01-SAMSS-024,


A7
too widely spaced supports and excessive stacking height. Para. 4.3

No end damage exists due to use of improper end hooks for lifting or
due to improper nesting or denesting techniques, or due to 01-SAMSS-024,
A8
longitudinal shifting of the pipe and striking the end of the pipe, which Para. 4.3
would cause cutting of the manufacturer's bevel.

No Fatigue cracks exist due to excessive static and cyclic loads as a 01-SAMSS-024,
A9
result of vertical vibrations during transportation. Para. 4.3

No Abrasion or peening exists due to rubbing or striking of the pipe 01-SAMSS-024,


A10
wall against other objects. Para. 4.3

API RP 5L1, American Petroleum Institute Recommended Practice


for Railroad Transportation of Line Pipe shall be followed and shall
be considered part of 01-SAMSS-024. The same recommendations
01-SAMSS-024,
A11 shall apply to transportation other than by rail, except as modified in
Para. 4.3
this Specification. Attachment 1 is API RP 5L1 Spec in entirety.
Piping shall be properly handled and
stored per spec.

B Packing:

02-SAMSS-005,
C1 All fittings must be protected from mechanical damage.
Para. 10.5

Welding ends must be protected with suitable wood, plastic, or metal 02-SAMSS-005,
C2
covers. Para. 10.5

Fittings must be packaged in steel-banded wooden crates or secured 02-SAMSS-005,


C3
to skids. Para. 10.5

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 30-Apr-2017 - REV. 2015.03.00 (Standards Cutoff - March 2015) Rev. 2015.03.00 31-Mar-15

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Receiving Inspection of Power Piping & Auxillaries SAIC-F-2022 30-Apr-17 MECH-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM RE-INSP
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A
No. DATE

REMARKS:

ATTACHMENTS:

REFERENCE DOCUMENTS:
1. 32-SAMSS-021, Manufacture of Industrial Boilers, (12 January 2013)
2. 01-SAMSS-024, Pipe Handling and Nesting, (21 June 2011)
3. 02-SAMSS-005, Butt Welding Pipe Fittings, (20 Feb 2012)

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Saudi Aramco: Company General Use