Professional Documents
Culture Documents
Locating Repeatability VFL/VFM:3μm VFJ/VFK:10μm
Zero Clearance between Reference Hole and Expansion Locating Pin PAT.
Workpiece Workpiece
Clearance
Expansion
Locating Pin Locating Pin
Action Description
Expansion Locating Pin Object for Locating
General Locating Pin consists of : Round Pin and Diamond Pin.
Kosmek Expansion Locating Pin consists of : Datum Cylinder and
Cut Cylinder.
Features High-Power
Series
Simple Arrangement Easy to Check the Accuracy For Shallow Workpiece Hole
Pneumatic Series
The compact body can be installed The same core part with X on the flange The low head pin can be used for
close to the clamp, so fixture design top allows to determine the origin and shallow workpiece hole. Hydraulic Series
is more simple. measure the distance accuracy.
Valve / Coupler
Work Clamp Measure the Distance Accuracy Hydraulic Unit
Probe
Expansion Locating Pin Manual Operation
Shallow Hole
Low Head
Accessories
※1
Cautions / Others
◎ φ0.01 X
D C
Hole Clamp
X SFA
Set Close
SFC
Air blow prevents foreign substances Seating confirmation is available Release confirmation is available TLB-2
from coming in. by using the gap sensor. by using the gap sensor. TLA-1
Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
※This drawing shows VFL.
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
Low Pressure DT
Block Cylinder
MAX. 7MPa DBA
Model V FL → P.9 3 9 Mod e l VFM → P. 939 M ode l VFJ → P. 975 M ode l VFK → P. 97 5
DBC
Centering Vise
Type High Accuracy Model Multi-Purpose Model FVA
Locating Repeatability 3μm 10μm FVD
FVC
Single Action Double Action Single Action Double Action
Control Method Control Valve
(Spring Lock/Hydraulic Release) (Hydraulic Lock/Hydraulic Release) (Hydraulic Lock/Spring Release) (Hydraulic Lock/Hydraulic Release)
BZL
Operating Pressure Range 2.5 ∼ 7 MPa 2.5 ∼ 7 MPa 1.5 ∼ 7 MPa BZT
BZX/JZG
Pallet Clamp
Taper Sleeve Steel Ball
VS
VT
Expansion
Locating Pin
VF L
Action
VF M
VF J
VF K
Released State Locked State Released State Locked State
Pull Stud Clamp
FP
Taper sleeve expands. Steel balls come out from the pin.
FQ
Customized
Spring Cylinder
Sample Reference Finishing Line / Dividing Line Locating Casting Core Holes
DW A /DW B
938
Expansion Locating Pin Locating Repeatability:3μm m od e l VFL/V F M
PAT.
Hydrau l ic
Exp ansion L oc atin g P i n
Model VFL/VFM
Hydraulic・Single Action/Double Action
Locating Repeatability:3μm
Index
・ Standard P.947
・ Standard P.963
Cautions
939
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Action Description This is a simplified drawing of VFL / VFM (Standard). Series
Pneumatic Series
model VFL model VFM
Hydraulic Series
Phasing Pin
Taper Sleeve Phasing Pin
Taper Sleeve Valve / Coupler
Rod Rod Hydraulic Unit
Manual Operation
Mounting Bolt Body Accessories
Mounting Bolt Body
Cautions / Others
Hole Clamp
SFA
SFC
Air Blow Port
Air Blow Port Swing Clamp
LHA
Spring (for Lock) LHC
Base Plate
Hydraulic Release Port LHS
Piston Hydraulic Lock Port LHW
LT/LG
Base Plate
TLA-2
Hydraulic Release Port Piston
TLB-2
TLA-1
Link Clamp
LK A
About Reference Locating and Orientation LK C
LK W
Cut Mark LM/LJ
Taper Sleeve
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
360°Contact Body Shaft (High Rigidity) Thinned External Surface
TC
Air Sensing
Lift Cylinder
VFL/VFM -D:Datum V FL /V FM - C: Cut
LLW
Reference Locating One Direction Locating
Compact Cylinder
LL
model VFL model VFM LLR
LLU
DP
Workpiece Workpiece
・VFL:When release hydraulic pressure is ON, the taper sleeve DR
Base Plate Release Hydraulic Pressure When loading workpiece When unloading workpiece Control Valve
Lock Hydraulic
ON Pressure OFF BZL
Base Plate Release Hydraulic Pressure BZT
ON BZX/JZG
Pallet Clamp
VS
VT
When locating Expansion
Locating Pin
VF L
・VFL:When release hydraulic pressure is OFF, VF M
VFJ
the piston/rod descend and the taper sleeve is expanded
VFK
to locate the workpiece with high accuracy.
・VFM:When release hydraulic pressure is OFF and lock hydraulic Pull Stud Clamp
Air Blow
pressure is ON, the piston/rod descend and the taper sleeve FP
ON
FQ
is expanded to locate the workpiece with high accuracy.
Air Blow Customized
ON (Seating is required for standard and release confirmation Spring Cylinder
Lock Hydraulic
models.) Pressure ON DW A /DW B
Release Hydraulic Pressure
Release Hydraulic Pressure
OFF
OFF 940
Expansion Locating Pin Locating Repeatability:3μm model VFL/V F M
System References
● Repeated locating accuracy of 3μm ( One step locating reduces setup time! )
● Avoid deterioration of workpiece accuracy when changing pallets to perform multiple operations.
● Using with hole clamp allows for 5-face machining, minimum setup and more compact fixture!
2 4 3 4
model VFL/VFM-D model VFL/VFM-C
Expansion Locating Pin (Equivalent to Round Pin) Expansion Locating Pin (Equivalent to Diamond Pin)
5 6
Work Clamp
(Hole Clamp)
1 4
Workpiece (Pallet)
Base Plate
Application Examples
Enough
Clearance
941
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Essential Points Series
Manual Operation
Accessories
n
pe
X LK C
Per
・ VFL/VFM-C (Cut: for one direction locating) locates in one direction (Y-axis), LK W
LM/LJ
so phasing is necessary. When mounting, ensure the VFL/VFM-C (cut) cut mark T MA - 2
T MA - 1
is perpendicular to VFL/VFM-D (datum).
VFL/VFM-D (Datum) VFL/VFM-C (Cut) Work Support
(There is a cut mark (▲) on top of the flange on the VFL/VFM-C unit that For Reference Locating (X-axis / Y-axis) For One Direction (Y-axis) LD
shows the locating direction.) (Equivalent to Round Pin) (Equivalent to Diamond Pin) LC
T NC
TC
Air Sensing
Lift Cylinder
4 Distance Accuracy between Expansion Locating Pins and between Workpiece Holes Compact Cylinder
LL
Work-
・ The distance accuracy for the expansion locating pin should be better than ±0.02mm. piece LLR
LLU
・ The distance accuracy of workpiece holes (pallet holes) (※1) should be DP
DR
within allowable difference. (Refer to Notes for Design .)
Base Plate DS
DT
Cylinder Distance
better than ±0.02 Block Cylinder
DBA
DBC
・ Standard model and -M:Release Confirmation model have no seating surface FVC
Control Valve
(reference surface towards Z-axis). Please prepare the seat separately. Z Seat
BZL
BZT
Base Plate BZX/JZG
Expansion
Work Clamp Expansion locating pin can be used for locating only. Locating Pin
942
Expansion Locating Pin Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL
VFL 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7
1 Body Size
2 Design No.
0 :Revision Number
Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
+ 0.022 + 0.022
Workpiece Hole Diam. φWA H8 8 0 9 0 10 + 0.022
0 11 + 00.027 12 + 00.027 13 + 00.027 14 + 00.027 15 + 00.027 16 + 00.027 17 + 00.027 18 + 00.027 19 + 00.033 20 + 00.033
VFL2000 Selection Range
VFL3000 Selection Range
VFL4000 Selection Range
4 Functions
Datum Cut
5 Seating Height
Model No.
15 20 25 30
VFL2000 Selection Range
VFL3000 Selection Range
VFL4000 Selection Range
VFL5000 Selection Range Note:
VFL6000 Selection Range Prepare the seat separately for 6 Option Blank:Standard
and M:Release Confirmation Model.
943
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Series
Pneumatic Series
Hydraulic Series
Valve / Coupler
Hydraulic Unit
Manual Operation
Accessories
7 Port Position Required only when selecting 6 Option:B (with Seating Surface), M (Release Confirmation Model). LHW
LT/LG
TLA-2
R :Refer to External Dimensions TLB-2
Note: TLA-1
L :Refer to External Dimensions
Refer to Port Position on each External Dimension page for details. Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VF L
VFM
VFJ
VFK
944
Expansion Locating Pin Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL
Specifications:VFL5000 / VFL6000
Model No. VFL5000 VFL6000
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300
Workpiece Hole Diam. (Standard Diam.) mm φ21H8 + 0.033
0 φ22H8 + 0.033
0 φ23H8 + 0.033
0 φ24H8 + 0.033
0 φ25H8 + 0.033
0 φ26H8 + 0.033
0 φ27H8 + 0.033
0 φ28H8 + 0.033
0 φ29H8 + 0.033
0 φ30H8 + 0.033
0
Notes:
※1. Expanding force shows the calculated value when coefficient friction is μ0.2.
Refer to the following for the relative equation of expanding force and allowable workpiece weight for locating.
※2. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates with spring and releases with hydraulic pressure. (Hydraulic Pressure Single Action)
2. This cylinder is used only for locating and does not have a clamping function.
Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating
F W F
945
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Thrust Load/Displacement Curve Series
Pneumatic Series
This graph shows the relationship between thrust load and displacement.
Thrust load is the static load applied perpendicular to the center axis of the VFL (Hydraulic Expansion Locating Pin).
Hydraulic Series
Note :
Valve / Coupler
This graph shows the thrust load (static load) on a single datum (VFL-D) cylinder
Hydraulic Unit
that is not used with any other cylinders, etc.
Manual Operation
Accessories
Displacement
Cautions / Others
【How to Read the Thrust Load/Displacement Curve】
Workpiece
ex.) When using VFL2000-100
Thrust Load
Requirement : When a 2000N thrust load is Hole Clamp
Displacement (mm)
0.014 0.014 TLA-1
0.010 0.010 LK A
LK C
0.008 0.008
VFL2000-090 LK W
0.006 0.006
LM/LJ
0.004 0.004 T MA - 2
0.002 0.002 T MA - 1
0 0 Work Support
0 1000 2000 3000 4000 0 1000 2000 3000 4000
LD
Thrust Load (N) Thrust Load (N) LC
T NC
VFL4000 VFL5000 TC
Air Sensing
0.020 0.020 Lift Cylinder
VFL4000-160 VFL5000-210 VFL5000-250
0.018 0.018 LLW
0.016 0.016
Compact Cylinder
Displacement (mm)
Displacement (mm)
0.014 BZT
0.012 VFL6000-300 BZX/JZG
946
Expansion Locating Pin Standard Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL2 / VFL3 / VFL4
Full Stroke
φR
U V
(Expanding Area)
(E)
(E)
Datum Diameter Datum Diameter
J
A
S
Q Q
⊥ 0.05 Y
WB or more
6.3S
View A
6.3S
1 or less
1 or less
5 Seating Height:H15
φL
φM
Expanding Area
60°
φN
G ◎ φ0.01 X
C
※2
H
Notes:
A
Y
B
F
X
9.5
60°
Datum Diameter
K
E
φN
1
◎ φ0.01 X
C
G
H
A
※2
B
Y
F
φDh6
6.5
X
9.5
※3
1-O-ring (Included)
W
947
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
Q Q 2-ME Thread
Hydraulic Series
★ ★
Valve / Coupler
Hydraulic Unit
Manual Operation
MA
★ ★ Accessories
Cautions / Others
※4
Air Blow Port MC
φMB
Hole Clamp
Mounting
6.3
Swing Clamp
Surface roughness of mounting surface, but this is not a malfunction. LHA
※6. Prepare the hydraulic release port on the bottom within
MF or more
LHC
8.5±0.1
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD
Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 0.033 LC
0 0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 32 37 42 32 37 42 32 37 42 32 37 42 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 34 39 44 34 39 44 34 39 44 34 39 44 34 39 44
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 Compact Cylinder
C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 LL
0 0 0 LLR
D h6 (Body Side) 15 - 0.011 15 - 0.011 18 - 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DS
DT
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Block Cylinder
φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt
Full Stroke
S
(E)
(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)
30°
30°
.Q
6.3S
(Cut:One Direction Locating)
7 or more
6.3S
View A
1 or less
1 or less
φL
φM
Expanding Area
60°
φN
◎ φ0.01 ZA
C
1.5
G
H
A
※2
ZB Notes:
B
F
ZA
AB
949
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
.Q
Hydraulic Series
P.C.D
※4
Air Blow Port 3-ME Thread
Valve / Coupler
φ4
Hydraulic Unit
Manual Operation
Accessories
Cautions / Others
★ ★
30°
30°
Hole Clamp
SFA
※4 SFC
Air Blow Port
φ4 Swing Clamp
LHA
LHC
30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3
※5
※4. Install the air blow port choosing one port from two ★ parts. LT/LG
S
6.3S
Mounting
6.3
※5. There might be foam near the flange bottom depending on TLA-2
Surface
roughness of mounting surface, but this is not a malfunction. TLB-2
MF or more
MG±0.1
※6. Prepare the hydraulic release port on the bottom within TLA-1
the range of φMD.
Link Clamp
1. Make sure to check the cautions for cylinder mounting distance
LK A
accuracy, workpiece hole distance accuracy and mounting phase LK C
before installation. (Refer to P.1011.) LK W
φMD ±0.05※6 Hydraulic Release Port
※6
LM/LJ
T MA - 2
T MA - 1
Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 38 43 48 38 43 48 38 43 48 38 43 48 38 43 48 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 LLU
B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC
N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp
U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-119 (90°) Expansion
Locating Pin
AB 11 12.5 VF L
AC 8 8.3 VFM
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFJ
VFK
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5
MD 21.1 24.6 Pull Stud Clamp
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more FP
MF 12.5 14 FQ
Customized
MG 10 11.5
Spring Cylinder
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 DW A /DW B
Weight g 190 220 250 190 220 260 190 230 260 200 230 260 200 230 270 350 400 440 350 400 450 350 400 450 360 410 460 360 410 460
950
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL2-B / VFL3-B / VFL4-B
Full Stroke
φR
U V
(Expanding Area)
(K)
(K)
S
J
A (When Releasing) (At Full Stroke)
45°
45°
BL
FC
O
W
.Q
P.C.D
BB
⊥ 0.05 Y
WB or more
6.3S
View A
6.3S
1 or less
1 or less
5 Seating Height:H15
φL
φM
60°
Expanding Area
G φN
C
◎ φ0.01 X
1
H±0.005
Notes:
A
Y
F
X 1-O-ring (Included)
9.5
※2. Set the O-ring to the mounting hole side (fixture side) before
BC
※2 mounting the body.
1-O-ring (Included)
1. When mounting the product, use two mounting bolts
W
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
5 Seating Height:H20 / H25 (BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
φL
seating confirmation air port.
φM
60°
Expanding Area
φN
R L
C
◎ φ0.01 X
1
Y
F
φDh6
6.5
X 1-O-ring (Included)
9.5
High-Power
Machining Dimensions for Mounting Series
Manual Operation
Accessories
45°
45°
45°
45°
Cautions / Others
Hole Clamp
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFA
φMB φMA φMA φMB SFC
※3 Notes: LHC
S
Mounting
6.3S
6.3
Surface ※3. There might be foam near the flange bottom depending on LHS
LHW
roughness of mounting surface, but this is not a malfunction.
MF or more
8.5±0.1
LT/LG
※4. Prepare the hydraulic release port on the bottom within
TLA-2
the range of φMD.
TLB-2
1. Make sure to check the cautions for cylinder mounting distance
TLA-1
accuracy, workpiece hole distance accuracy and mounting phase
※4 before installation. (Refer to P.1011.) Link Clamp
Hydraulic Release Port
LK A
※4
φMD±0.05 LK C
LK W
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD
Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 0.033 LC
0 0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 32 37 42 32 37 42 32 37 42 32 37 42 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 34 39 44 34 39 44 34 39 44 34 39 44 34 39 44
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Compact Cylinder
D h6 (Body Side)
0
15 - 0.011 15 - 00.011 0
18 - 0.011 LL
+ 0.018 + 0.018 + 0.018 LLR
D H7 (Machining Hole) 15 0 15 0 18 0
LLU
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DP
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DR
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 DS
DT
J 4.6 5.1 6
K 7.5 8 9.5 Block Cylinder
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7 DBA
DBC
M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18
N 15.5 16.5 17.5 18.5 19.5 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 Centering Vise
P 4 4 5 FVA
FVD
Q 24 28 35
FVC
R 33 37 47
Control Valve
S 9.5 9.5 11.5
BZL
U M5×0.8×12 M5×0.8×12 M6×1×16
BZT
V M6×1 M6×1 M8×1.25 BZX/JZG
W AS568-013 (90°) AS568-013 (90°
) AS568-015 (90°)
Pallet Clamp
BA 12 13 14 14 15 16 17 18 19 20 21 22 23 VS
BB 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 VT
BC AS568-006 (90°) AS568-006 (90°
) AS568-007 (90°) Expansion
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5 Locating Pin
VF L
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5
VFM
MA 3 3 4
VFJ
MB 3 3 4 VFK
MD 12.1 12.1 15.1
Pull Stud Clamp
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FP
MF 10.5 10.5 11
FQ
+ 0.022 + 0.022
WA 8 0 9 0 10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0
+ 0.027 + 0.033 + 0.033
Customized
WB 4 4.5 5.5 Spring Cylinder
DW A /DW B
Weight g 70 80 100 70 80 100 70 80 100 70 80 100 80 100 110 80 100 110 80 100 120 80 100 120 130 160 180 130 160 190 130 160 190 140 160 190 140 160 190
952
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL5-B / VFL6-B
Full Stroke
S
Datum Diameter Datum Diameter
12
12
A (When Releasing) (At Full Stroke)
30°
BD
BL
OW
°
60
BB
FC
.Q
φ1.5
6.3S
(Cut:One Direction Locating)
7 or more
6.3S
View A
1 or less
1 or less
φL
φM
60°
Expanding Area
7.5
φN
C
1.5
G ◎ φ0.01 ZA
H±0.005
A
ZB Notes:
F
ZA
AB
1-O-ring (Included)
※2. Set the O-ring to the mounting hole side (fixture side) before
BC
※2 mounting the body.
1-O-ring (Included)
W 1. When mounting the product, use three mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
seating confirmation air port.
Port Position
R L
Note:
3. Please make sure that the port positions are correct.
953
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
.Q
P.C.D
Hydraulic Series
P.C.D
.Q
Air Blow Port 3-ME Thread 3-ME Thread Air Blow Port
Valve / Coupler
φ4 φ4
Hydraulic Unit
Manual Operation
Accessories
Cautions / Others
30°
30°
°
60
60
°
Hole Clamp
SFA
SFC
Seating Confirmation Air Port Seating Confirmation Air Port Swing Clamp
φ4 φ4 LHA
LHC
30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3
※3 ※3. There might be foam near the flange bottom depending on LT/LG
S
Mounting
6.3S
6.3
Work Support
Model No. VFL5000-□-□-B□ VFL6000-□-□-B□
LD
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 LC
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 T NC
Workpiece Hole Diameter (Standard Diam.) φ21H8 + 0.033
0 φ22H8 + 0.033
0 φ23H8 + 0.033
0 φ24H8 + 0.033
0 φ25H8 + 0.033
0 φ26H8 + 0.033
0 φ27H8 + 0.033
0 φ28H8 + 0.033
0 φ29H8 + 0.033
0 φ30H8 + 0.033
0 TC
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less Air Sensing
Datum Diameter Lift Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more LLW
Full Stroke 1
Compact Cylinder
A 38 43 48 38 43 48 38 43 48 38 43 48 38 43 48 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5
LL
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LLR
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 LLU
AC 8 8.3 VS
VT
BA 24 25 26 27 28 29 30 31 32 33
BB 12.5 13 13.5 14 14.5 15 15.5 16 16.5 17 Expansion
Locating Pin
BC AS568-007 (90°) 1BP5 VF L
BD 12.5 13 13.5 14 14.3 15 15.5 16 16.5 16.5 VFM
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFJ
VFK
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5
MD 21.1 24.6 Pull Stud Clamp
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more FP
MF 12.5 14 FQ
Customized
MG 10 11.5
Spring Cylinder
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 DW A /DW B
Weight g 190 220 250 190 220 260 190 230 260 200 230 260 200 230 270 350 400 440 350 400 450 350 400 450 360 410 460 360 410 460
954
Expansion Locating Pin Release Confirmation Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL2-M / VFL3-M / VFL4-M
Full Stroke
φR
U V
T
EX
(Expanding Area)
S
(E)
(E)
Datum Diameter Datum Diameter
J
A (When Releasing) (At Full Stroke)
45°
45°
R
BL
O
NS
O
W
SE
.Q
P.C.D
⊥ 0.05 Y
WB or more
6.3S
View A
6.3S
1 or less
1 or less
5 Seating Height:H15
φL
φM
Expanding Area
60°
G φN
C
◎ φ0.01 X
1
Notes:
A
Y
B
F
X
9.5
※2. Set the O-ring to the mounting hole side (fixture side) before
※2
1-O-ring (Included) mounting the body.
W 1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
5 Seating Height:H20 / H25 (EXT:Air Vent Port, BLOW:Air Blow Port, SENSOR:Release
Confirmation Air Port) Continuously supply air pressure to
φL
the air blow port and release confirmation air port.
φM
3. This product has no seat. Choose option -B:with Seating
Expanding Area
Datum Diameter
Port Position
K
E
φN
R L
1
C
Y
F
φDh6
6.5
X
9.5
Note:
4. Please make sure that the port positions are correct.
955
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
Air Vent Port 2-ME Thread 2-ME Thread Air Vent Port
Hydraulic Series
φMC φMC
Valve / Coupler
P.C.D .Q
.Q P.C.D
Hydraulic Unit
T
T
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port
SFC
φMB φMA φMA φMB
φDH7 Swing Clamp
30° ⊥ 0.01 Z
Z LHA
Must be 1.3
※3 Notes: LHC
S
6.3S
Mounting
6.3
Surface LHS
※3. There might be foam near the flange bottom depending on
LHW
roughness of mounting surface, but this is not a malfunction.
MF or more
8.5±0.1
LT/LG
※4. Prepare the hydraulic release port on the bottom within
TLA-2
the range of φMD. TLB-2
1. Make sure to check the cautions for cylinder mounting distance TLA-1
accuracy, workpiece hole distance accuracy and mounting phase
※4 Link Clamp
Hydraulic Release Port before installation. (Refer to P.1011.)
※4
LK A
φMD±0.05 LK C
LK W
External Dimensions and Machining Dimensions for Mounting (mm) LM/LJ
T MA - 2
Model No. VFL2000-□-□-□-M□ VFL3000-□-□-□-M□ VFL4000-□-□-□-M□
T MA - 1
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25
LD
Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022
0 φ9H8 + 0.022
0 φ10 + 0.022
H8 0 φ11 + 0.027
H8 0 φ12 + 0.027
H8 0 φ13 + 0.027
H8 0 φ14 + 0.027
H8 0 φ15 + 0.027
H8 0 φ16 + 0.027
H8 0 φ17 + 0.027
H8 0 φ18 + 0.027
H8 0 φ19 + 0.033
H8 0 φ20 + 0.033
H8 0
LC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less T NC
Datum Diameter
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more TC
Air Sensing
Full Stroke 0.65 0.75 1.0
Lift Cylinder
A 32 37 42 32 37 42 32 37 42 32 37 42 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 34 39 44 34 39 44 34 39 44 34 39 44 34 39 44 LLW
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5
Compact Cylinder
C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4
LL
0
D h6 (Body Side) 15 - 0.011 15 - 00.011 0
18 - 0.011 LLR
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0 LLU
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10
DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11
DS
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DT
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25
Block Cylinder
J 4.6 5.1 6 DBA
K 7.5 8 9.5 DBC
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7
Centering Vise
M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18
FVA
N 14.5 9 9 14.5 10 10 14.5 11 11 14.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 22.5 17 17 22.5 18 18 22.5 19 19 22.5 20 20 22.5 21 21 FVD
P 4 4 5 FVC
Q 24 28 35 Control Valve
R 33 37 47 BZL
S 9.5 9.5 11.5 BZT
BZX/JZG
T 35° 30° 30°
U M5×0.8×12 M5×0.8×12 M6×1×16 Pallet Clamp
MF 10.5 10.5 11 FQ
+ 0.022 + 0.022 Customized
WA 8 0 9 0 10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0
+ 0.027 + 0.033 + 0.033
Spring Cylinder
WB 4 4.5 5.5 DW A /DW B
Weight g 70 80 100 70 80 100 70 80 100 70 80 100 80 100 110 80 100 110 80 100 120 80 100 120 130 160 180 130 160 190 130 160 190 140 160 190 140 160 190
956
Expansion Locating Pin Release Confirmation Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL5-M / VFL6-M
φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt
Full Stroke
S
(E)
(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)
30°
BL
°
OW
60
OR
30
EX
T NS
SE
°
.Q
6.3S
(Cut:One Direction Locating)
7 or more
6.3S
View A
1 or less
1 or less
φL
φM
Expanding Area
60°
φN
◎ φ0.01 ZA
C
1.5
G
H
A
ZB Notes:
B
F
ZA
AB
※2. Set the O-ring to the mounting hole side (fixture side) before
※2
1-O-ring (Included) mounting the body.
W 1. When mounting the product, use three mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(EXT:Air Vent Port, BLOW:Air Blow Port, SENSOR:Release
Confirmation Air Port) Continuously supply air pressure to
the air blow port and release confirmation air port.
3. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
Port Position
R L
High-Power
Machining Dimensions for Mounting Series
.Q
P.C.D
Hydraulic Series
P.C.D
.Q
Air Blow Port 3-ME Thread 3-ME Thread Air Blow Port
Valve / Coupler
φ4 φ4
Hydraulic Unit
Manual Operation
Accessories
Cautions / Others
30°
30°
°
60
60
Hole Clamp
°
30
SFA
30
°
SFC
Air Vent Port Release Confirmation Air Port Release Confirmation Air Port Air Vent Port Swing Clamp
φ4 φ4 φ4 φ4 LHA
LHC
30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3
※3 ※3. There might be foam near the flange bottom depending on LT/LG
S
Mounting
6.3S
6.3
1. Make sure to check the cautions for cylinder mounting distance Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase LK A
before installation. (Refer to P.1011.) LK C
LK W
φMD ±0.05※4 Hydraulic Release Port
※4
LM/LJ
T MA - 2
T MA - 1
Work Support
H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
5 Seating Height
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 38 43 48 38 43 48 38 43 48 38 43 48 38 43 48 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 LLU
B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC
N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp
U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-119 (90°) Expansion
Locating Pin
AB 11 12.5 VF L
AC 8 8.3 VFM
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFJ
VFK
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5
MD 21.1 24.6 Pull Stud Clamp
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more FP
MF 12.5 14 FQ
Customized
MG 10 11.5
Spring Cylinder
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 DW A /DW B
Weight g 190 220 250 190 220 260 190 230 260 200 230 260 200 230 270 350 400 440 350 400 450 350 400 450 360 410 460 360 410 460
958
Expansion Locating Pin Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM
VFM 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7
1 Body Size
2 Design No.
0 :Revision Number
Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
+ 0.022 + 0.022
Workpiece Hole Diam. φWA H8 8 0 9 0 10 + 0.022
0 11 + 00.027 12 + 00.027 13 + 00.027 14 + 00.027 15 + 00.027 16 + 00.027 17 + 00.027 18 + 00.027 19 + 00.033 20 + 00.033
VFM2000 Selection Range
VFM3000 Selection Range
VFM4000 Selection Range
4 Functions
Datum Cut
5 Seating Height
Model No.
15 20 25 30
VFM2000 Selection Range
VFM3000 Selection Range
VFM4000 Selection Range
VFM5000 Selection Range Note:
VFM6000 Selection Range Prepare the seat separately for 6 Option Blank:Standard
and M:Release Confirmation Model.
959
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Series
Pneumatic Series
Hydraulic Series
Valve / Coupler
Hydraulic Unit
Manual Operation
Accessories
7 Port Position Not required only when selecting 6 Option:Blank (Standard) of VFM2000 / VFM3000 / VFM4000. LHW
LT/LG
TLA-2
R :Refer to External Dimensions TLB-2
Note: TLA-1
L :Refer to External Dimensions
Refer to Port Position on each External Dimension page for details. Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VFL
VF M
VFJ
VFK
960
Expansion Locating Pin Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM
Specifications:VFM5000 / VFM6000
Model No. VFM5000 VFM6000
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300
Workpiece Hole Diam. (Standard Diam.) mm φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +00.033 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
Notes:
※1. Expanding force shows the calculated value when coefficient friction is μ0.2.
Refer to the following for the relative equation of expanding force and allowable workpiece weight for locating.
※2. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates and releases with hydraulic pressure. (Hydraulic Pressure Double Action)
2. This cylinder is used only for locating and does not have a clamping function.
Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating
F W F
961
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Thrust Load/Displacement Curve Series
Pneumatic Series
This graph shows the relationship between thrust load and displacement.
Thrust load is the static load applied perpendicular to the center axis of the VFM (Hydraulic Expansion Locating Pin).
Hydraulic Series
Note :
Valve / Coupler
This graph shows the thrust load (static load) on a single datum (VFM-D) cylinder
Hydraulic Unit
that is not used with any other cylinders, etc.
Manual Operation
Accessories
Displacement
Cautions / Others
【How to Read the Thrust Load/Displacement Curve】
Workpiece
ex.) When using VFM2000-100
Thrust Load
Requirement : When a 2000N thrust load is Hole Clamp
Displacement (mm)
0.014 0.014 TLA-1
0.010 0.010 LK A
LK C
0.008 0.008
VFM2000-090 LK W
0.006 0.006
LM/LJ
0.004 0.004 T MA - 2
0.002 0.002 T MA - 1
0 0 Work Support
0 1000 2000 3000 4000 0 1000 2000 3000 4000
LD
Thrust Load (N) Thrust Load (N) LC
T NC
VFM4000 VFM5000 TC
Air Sensing
0.020 0.020 Lift Cylinder
VFM4000-160 VFM5000-210 VFM5000-250
0.018 0.018 LLW
0.016 0.016
Compact Cylinder
Displacement (mm)
Displacement (mm)
0.014 BZT
0.012 VFM6000-300 BZX/JZG
962
Expansion Locating Pin Standard Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM2 / VFM3 / VFM4
Full Stroke
φR
U V
(Expanding Area)
(E)
(E)
Datum Diameter Datum Diameter
J
A
S
Q Q
⊥ 0.05 Y
WB or more
6.3S
View A
6.3S
1 or less
1 or less
5 Seating Height:H15
φL
φM
Expanding Area
60°
φN
G ◎ φ0.01 X
C
※2
H
Y Notes:
B
F
X
※2. Do not use spring washer or toothed lock washer.
1-O-ring (Included)
18
※3. Set the O-ring to the mounting hole side (fixture side) before
W
mounting the body.
1-O-ring (Included)
※3 1. When mounting the product, use two mounting bolts
W (Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
5 Seating Height:H20 / H25 2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
φL
φM
Expanding Area
60°
Datum Diameter
K
E
φN
1
◎ φ0.01 X
C
G
H
※2
B
Y
A
φDh6
5
X
1-O-ring (Included)
18
※3
1-O-ring (Included)
W
963
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
Q Q 2-ME Thread
Hydraulic Series
★ ★
Valve / Coupler
Hydraulic Unit
Manual Operation
MA
★ ★ Accessories
Cautions / Others
※4
Air Blow Port MC
φMB
Hole Clamp
Mounting※5
6.3
Swing Clamp
Surface roughness of mounting surface, but this is not a malfunction. LHA
※6. Prepare the hydraulic lock port within . LHC
7.5
LHS
17±0.1
1. Make sure to check the cautions for cylinder mounting distance LT/LG
7
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD
Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 0.033 LC
0 0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41 46 51 41 46 51 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 Compact Cylinder
C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 LL
0 0 0 LLR
D h6 (Body Side) 15 - 0.011 15 - 0.011 18 - 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DS
DT
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Block Cylinder
φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt
Full Stroke
S
(E)
(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)
30°
30°
BL
CK
OW
LO
.Q
6.3S
(Cut:One Direction Locating)
7 or more
6.3S
View A
1 or less
1 or less
φL
φM
Expanding Area
60°
φN
C
◎ φ0.01 ZA
1.5
G
A
ZB Notes:
B
F
φDh6
direction locating). indicates the locating direction.
5
ZA
8
1-O-ring (Included)
1. When mounting the product, use three mounting bolts
BC
(Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
W Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
Port Position
R L
Note:
4. Please make sure that the port positions are correct.
965
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
.Q
P.C.D
Hydraulic Series
P.C.D
.Q
3-ME Thread 3-ME Thread
Valve / Coupler
Hydraulic Unit
Manual Operation
Accessories
Cautions / Others
30°
30°
30°
30°
Hole Clamp
SFA
SFC
Air Blow Port Hydraulic Lock Port Hydraulic Lock Port Air Blow Port
φ4 φ4 φ4 φ4 Swing Clamp
LHA
LHC
30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3
※2. There might be foam near the flange bottom depending on LT/LG
S
6.3S
Mounting※2
6.3
Surface
roughness of mounting surface, but this is not a malfunction. TLA-2
8.5 or more
※3. Prepare the hydraulic release port on the bottom within TLB-2
the range of φDH7. TLA-1
1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.) LK C
LK W
※3
Hydraulic Lock Port LM/LJ
T MA - 2
T MA - 1
Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 40 45 50 40 45 50 40 45 50 40 45 50 40 45 50 LLU
B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC
N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp
U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-022 (90°) Expansion
Locating Pin
BC AS568-007 (90°) 1BP5 VFL
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VF M
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5 VFJ
VFK
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 Pull Stud Clamp
Weight g 180 210 250 180 220 250 190 220 250 190 220 260 190 220 260 320 370 420 330 380 420 330 380 430 340 380 430 340 380 440 FP
FQ
Customized
Spring Cylinder
DW A /DW B
966
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM2-B / VFM3-B / VFM4-B
Full Stroke
φR
U V
(Expanding Area)
(K)
(K)
S
J
A (When Releasing) (At Full Stroke)
45°
45°
BL
FC
O
W
.Q
P.C.D
BB
⊥ 0.05 Y
WB or more
6.3S
View A
6.3S
1 or less
1 or less
5 Seating Height:H15
φL
φM
60°
Expanding Area
G φN
C
◎ φ0.01 X
1
H±0.005
Y Notes:
F
X 1-O-ring (Included)
※2. Set the O-ring to the mounting hole side (fixture side) before
BC
18
φN
R L
C
◎ φ0.01 X
1
Y
A
φDh6
5
X 1-O-ring (Included)
Seating Confirmation Air Port
BC
18
High-Power
Machining Dimensions for Mounting Series
Manual Operation
Accessories
45°
45°
45°
45°
Cautions / Others
Hole Clamp
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFA
φMB φMA φMA φMB SFC
Notes: LHC
S
Mounting※3
6.3S
6.3
Surface LHS
※3. There might be foam near the flange bottom depending on
LHW
roughness of mounting surface, but this is not a malfunction.
7.5
LT/LG
MF or more
TLA-2
※5. Prepare the hydraulic release port on the bottom within TLB-2
※4
TLA-1
1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.)
LK C
Hydraulic Lock Port ※4 Hydraulic Release Port ※5
LK W
±0.05 ※5
φMD LM/LJ
T MA - 2
External Dimensions and Machining Dimensions for Mounting (mm) T MA - 1
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LC
T NC
Workpiece Hole Diameter (Standard Diam.) φ8 + 0.022
H8 0 φ9 + 0.022
H8 0 φ10 + 0.022
H8 0 φ11 + 0.027
H8 0 φ12 + 0.027
H8 0 φ13 + 0.027
H8 0 φ14 + 0.027
H8 0 φ15 + 0.027
H8 0 φ16 + 0.027
H8 0 φ17 + 0.027
H8 0 φ18 + 0.027
H8 0 φ19 + 0.033
H8 0 φ20 + 0.033
H8 0
TC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less Air Sensing
Datum Diameter
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Lift Cylinder
LLW
Full Stroke 0.65 0.75 1.0
A 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41 46 51 41 46 51 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 Compact Cylinder
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LL
0 LLR
D h6 (Body Side) 15 - 0.011 15 - 00.011 18
0
- 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DR
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DS
DT
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25
J 4.6 5.1 6 Block Cylinder
N 15.5 16.5 17.5 18.5 19.5 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 FVA
FVD
P 4 4 5
FVC
Q 24 28 35
Control Valve
R 33 37 47
BZL
S 9.5 9.5 11.5
BZT
U M5×0.8×12 M5×0.8×12 M6×1×16 BZX/JZG
V M6×1 M6×1 M8×1.25
Pallet Clamp
W AS568-013 (90°) AS568-013 (90°) AS568-015 (90°) VS
BA 12 13 14 14 15 16 17 18 19 20 21 22 23 VT
BB 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 Expansion
BC AS568-006 (90°) AS568-006 (90°) AS568-007 (90°) Locating Pin
VFL
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5
VF M
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5
VFJ
MA 3 3 4 VFK
MB 3 3 4
Pull Stud Clamp
MD 12.1 12.1 15.1
FP
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FQ
MF 19 19 19.5 Customized
WA 8
+ 0.022
0 9 + 0.022
0 10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0
+ 0.027 + 0.033 + 0.033 Spring Cylinder
DW A /DW B
WB 4 4.5 5.5
Weight g 80 90 110 80 90 110 80 90 110 80 100 110 90 110 130 90 110 130 90 110 130 100 110 130 150 170 200 150 180 200 150 180 200 150 180 210 150 180 210 968
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM5-B / VFM6-B
Full Stroke
S
Datum Diameter Datum Diameter
12
12
A (When Releasing) (At Full Stroke)
30°
30°
BD
BL
CK
OW
LO
°
BB
FC
30
.Q
φ1.5
6.3S
(Cut:One Direction Locating)
7 or more
6.3S
View A
1 or less
1 or less
φL
φM
60°
Expanding Area
7.5
φN
C
1.5
G ◎ φ0.01 ZA
H±0.005
A
ZB Notes:
F
φDh6
direction locating). indicates the locating direction.
5
ZA
8
2-O-ring (Included)
1. When mounting the product, use three mounting bolts
BC
(Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
W Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(BLOW:Air Blow Port, FC:Seating Confirmation Air Port,
LOCK:Hydraulic Lock Port) Continuously supply air pressure
to the air blow port and seating confirmation air port.
Port Position
R L
Hydraulic Lock Port
Note:
3. Please make sure that the port positions are correct.
969
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
.Q
P.C.D
Hydraulic Series
P.C.D
.Q
3-ME Thread 3-ME Thread
Valve / Coupler
Hydraulic Unit
Manual Operation
Accessories
Cautions / Others
30°
30°
30°
30°
° Hole Clamp
30
SFA
Hydraulic Lock Port Hydraulic Lock Port
30
°
SFC
Air Blow Port φ4 φ4 Air Blow Port
φ4 Seating Confirmation Air Port Seating Confirmation Air Port φ4 Swing Clamp
φ4 φ4 LHA
LHC
30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3
※3. There might be foam near the flange bottom depending on LT/LG
S
Mounting※3
6.3S
6.3
※4. Prepare the hydraulic release port on the bottom within TLB-2
the range of φDH7. TLA-1
1. Make sure to check the cautions for cylinder mounting distance Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase LK A
before installation. (Refer to P.1011.) LK C
※4
Hydraulic Release Port LK W
LM/LJ
T MA - 2
Work Support
Model No. VFM5000-□-□-B□ VFM6000-□-□-B□
LD
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 LC
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 T NC
Workpiece Hole Diameter (Standard Diam.) φ21H8 + 0.033
0 φ22H8 + 0.033
0 φ23H8 + 0.033
0 φ24H8 + 0.033
0 φ25H8 + 0.033
0 φ26H8 + 0.033
0 φ27H8 + 0.033
0 φ28H8 + 0.033
0 φ29H8 + 0.033
0 φ30H8 + 0.033
0 TC
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less Air Sensing
Datum Diameter Lift Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more LLW
Full Stroke 1
Compact Cylinder
A 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 40 45 50 40 45 50 40 45 50 40 45 50 40 45 50
LL
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LLR
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 LLU
Weight g 180 210 250 180 220 250 190 220 250 190 220 260 190 220 260 320 370 420 330 380 420 330 380 430 340 380 430 340 380 440 Pull Stud Clamp
FP
FQ
Customized
Spring Cylinder
DW A /DW B
970
Expansion Locating Pin Release Confirmation Model Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM2-M / VFM3-M / VFM4-M
Full Stroke
φR
U V
T
EX
(Expanding Area)
S
(E)
(E)
Datum Diameter Datum Diameter
J
A (When Releasing) (At Full Stroke)
45°
45°
R
BL
O
NS
O
W
SE
.Q
P.C.D
⊥ 0.05 Y
WB or more
6.3S
View A
6.3S
1 or less
1 or less
5 Seating Height:H15
φL
φM
Expanding Area
60°
G φN
C
◎ φ0.01 X
1
Y Notes:
B
F
X
※2. Set the O-ring to the mounting hole side (fixture side) before
1-O-ring (Included)
18
Datum Diameter
K
Port Position
E
φN
1
C
Y
A
φDh6
5
X
Release Confirmation Air Port
1-O-ring (Included)
18
1-O-ring (Included)
※2 Note:
W 4. Please make sure that the port positions are correct.
971
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009
High-Power
Machining Dimensions for Mounting Series
Air Vent Port 2-ME Thread 2-ME Thread Air Vent Port
Hydraulic Series
φMC φMA
Valve / Coupler
P.C.D .Q
.Q P.C.D
Hydraulic Unit
T
T
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFA
φMB φMA φMC φMB SFC
φDH7 30°
Z ⊥ 0.01 Z Swing Clamp
Must be 1.3
LHA
S
Mounting※3
6.3S
6.3
※3. There might be foam near the flange bottom depending on LHS
LHW
roughness of mounting surface, but this is not a malfunction.
7.5
MF or more
LT/LG
※4. Prepare the hydraulic lock port within .
17±0.1
TLA-2
※5. Prepare the hydraulic release port on the bottom within the
※4
TLB-2
7
range of φMD.
TLA-1
1. Make sure to check the cautions for cylinder mounting distance
accuracy, workpiece hole distance accuracy and mounting phase Link Clamp
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD
Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 00.033 LC
0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41 46 51 41 46 51 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 Compact Cylinder
C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 LL
0 0 0 LLR
D h6 (Body Side) 15 - 0.011 15 - 0.011 18 - 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DS
DT
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Block Cylinder
φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt
Full Stroke
S
(E)
(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)
30°
30°
BL
CK
OW
LO
EX OR °
30
T NS
SE
30
°
.Q
6.3S
(Cut:One Direction Locating)
7 or more
6.3S
View A
1 or less
1 or less
φL
φM
Expanding Area
60°
φN
C
◎ φ0.01 ZA
1.5
G
A
ZB Notes:
B
F
φDh6
direction locating). indicates the locating direction.
5
ZA
8
1-O-ring (Included)
1. When mounting the product, use three mounting bolts
BC
(Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
W Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(EXT:Air Vent Port, BLOW:Air Blow Port,
SENSOR:Release Confirmation Air Port, LOCK:Air Lock Port)
Continuously supply air pressure to the air blow port and
release confirmation air port.
3. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
Port Position
R L
Hydraulic Lock Port
High-Power
Machining Dimensions for Mounting Series
.Q
P.C.D
Hydraulic Series
P.C.D
.Q
Air Blow Port 3-ME Thread 3-ME Thread Air Blow Port
Valve / Coupler
φ4 φ4
Hydraulic Unit
Manual Operation
Accessories
Cautions / Others
30°
30°
30°
30°
Hole Clamp
°
°
30
30
30
SFA
Hydraulic Lock Port Hydraulic Lock Port
30
°
°
SFC
φ4 φ4
Air Vent Port Release Confirmation Air Port Release Confirmation Air Port Air Vent Port Swing Clamp
φ4 φ4 φ4 φ4 LHA
LHC
30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3
※2. There might be foam near the flange bottom depending on LT/LG
S
Mounting※2
6.3S
6.3
※3. Prepare the hydraulic release port on the bottom within the TLB-2
range of φDH7. TLA-1
1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.) LK C
LK W
※3
Hydraulic Release Port LM/LJ
T MA - 2
T MA - 1
Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 40 45 50 40 45 50 40 45 50 40 45 50 40 45 50 LLU
B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC
N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp
U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-022 (90°) Expansion
Locating Pin
BC AS568-007 (90°) 1BP5 VFL
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VF M
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5 VFJ
VFK
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 Pull Stud Clamp
Weight g 180 210 250 180 220 250 190 220 250 190 220 260 190 220 260 320 370 420 330 380 420 330 380 430 340 380 430 340 380 440 FP
FQ
Customized
Spring Cylinder
DW A /DW B
974
Expansion Locating Pin Locating Repeatability:10μm model VFJ/V F K
PAT.
Hydraul ic
E xpans ion L oc atin g P i n
Model VFJ/VFK
Hydraulic・Single Action/Double Action
Locating Repeatability:10μm
Index
・ Standard P.981
・ Standard P.997
Cautions
975
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Action Description This is a simplified drawing of VFJ / VFK (Standard). Series
Pneumatic Series
model VFJ model VFK
Hydraulic Series
Steel Ball
Steel Ball Valve / Coupler
Stopper Hydraulic Unit
Stopper
Manual Operation
Mounting Bolt Body Accessories
Mounting Bolt Body
Cautions / Others
Hole Clamp
SFA
SFC
Air Blow Port
Air Blow Port Swing Clamp
Link Clamp
LK A
About Reference Locating and Orientation LK C
LK W
Steel Ball (3 Parts) Steel Ball (2 Parts) LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
VFJ/VFK- D:Datum V FJ/V FK - C:Cut
LLW
Reference Locating One Direction Locating
Compact Cylinder
LL
model VFJ model VFK LLR
LLU
DP
Workpiece Workpiece
・ VFJ:When lock hydraulic pressure is OFF, DR
the piston rod descends and steel balls are free to move. DS
Pallet Clamp
VS
VT
VFJ 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7
1 Body Size
2 Design No.
0 :Revision Number
Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150
Workpiece Hole Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8 φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
Diameter (mm) Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8 φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
VFJ2000 Selection Range
VFJ3000 Selection Range
4 Functions
Datum Cut
5 Seating Height
H15 :15mm
Seating Height
Note:
H20 :20mm
Prepare the seat separately for 6 Option Blank:Standard
H25 :25mm and M:Release Confirmation Model.
977
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Series
Pneumatic Series
Hydraulic Series
Valve / Coupler
Hydraulic Unit
Manual Operation
Accessories
7 Port Position Only for 6 Options:B (with Seating Surface), and M (Release Confirmation Model) LHW
LT/LG
R Vent Port Vent Port L TLA-2
R :As Illustrated TLB-2
Only for 6 M Only for 6 M TLA-1
L :As Illustrated
Link Clamp
LK A
Air Blow Port Air Blow Port LK C
LK W
Air Port Air Port LM/LJ
6 B :Seating Confirmation 6 B :Seating Confirmation T MA - 2
T MA - 1
6 M:Release Confirmation 6 M:Release Confirmation
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VFL
VFM
VF J
VFK
978
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ
Specifications:VFJ2000
Model No. VFJ2000-080 VFJ2000-090 VFJ2000-100
Workpiece Hole Diameter Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8
mm Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.4 ±0.4 ±0.5
at 2.5MPa 50
Expanding Force (F) ※2
at 5.0MPa 130
N
at 7.0MPa 190
Allowable Thrust Load ※3 N 450 600 800
Cylinder Capacity (Empty Action) cm3 0.08 0.10 0.12
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32
Specifications:VFJ3000
Model No. VFJ3000-110 VFJ3000-120 VFJ3000-130 VFJ3000-140 VFJ3000-150
Workpiece Hole Diameter Straight Hole φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
mm Taper Hole φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.6 ±0.6 ±0.7 ±0.7 ±0.8
at 2.5MPa 130
Expanding Force (F) ※2
at 5.0MPa 290
N
at 7.0MPa 420
Allowable Thrust Load ※3 N 1000 1000 1300 1300 1800
Cylinder Capacity (Empty Action) cm3 0.29 0.29 0.32 0.32 0.36
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32
Notes:
※1. It shows locating repeatability under the specific condition (no load).
※2. Expanding force shows the calculated value when coefficient friction is μ0.1.
Refer to the next page for the relative equation of expanding force and allowable workpiece weight for locating.
※3. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates with hydraulic pressure and releases with spring. (Hydraulic Pressure Single Action)
2. This cylinder is used only for locating and does not have a clamping function.
979
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating Series
Pneumatic Series
Hydraulic Series
F W
F
Horizontal Attitude μ Vertical Attitude Valve / Coupler
Hydraulic Unit
Seat
W Manual Operation
Accessories
Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5 Cautions / Others
Workpiece Weight (W) ≦ Workpiece Weight (W) ≦ Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5
Friction Coefficient of Workpiece Seat Face (μ)
Hole Clamp
SFA
SFC
Swing Clamp
LHA
LHC
LHS
LHW
LT/LG
TLA-2
TLB-2
TLA-1
Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VFL
VFM
VF J
VFK
980
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ2
φ3
φWA
M5×0.8×12 R2 or less 2.5°or less
K+0.5 or more
K+0.5 or more
19
2 or less
Workpiece Hole Diameter
φWC
12 12
VFJ-C
(Cut:One Direction Locating)
Notes:
※1. Do not use spring washer or toothed lock washer.
5 Seating Height:H15 1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Datum Diameter Use two jack bolts to remove the product, keeping it
φL g8 VFJ-C:Cut parallel to the mounting surface.
Steel Ball J φM 2. This product has no seat. Choose option -B:with Seating
3.5
G φN
C
◎ φ0.02 X
1
※1
H
A
B
F
φ15g7 -- 0.006
5
0.024
X
10.5
1-O-ring (Included)
AS568-013 (90° )
Datum Diameter
φL g8 VFJ-C:Cut
Steel Ball J φM
60°
K
E
3.5
φN
C
◎ φ0.02 X
1
G
H
A
※1
B
F
φ15g7 -- 0.006
5
0.024
X
10.5
1-O-ring (Included)
AS568-013 (90° )
981
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
★ ★ Cautions / Others
※2
Air Blow Port 10.5 Hole Clamp
φ3 SFA
SFC
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※2. Install the air blow port choosing one port from four ★ parts.
Z LHW
※3. There might be foam near the flange bottom depending on
Must be 1.3
LT/LG
※3
S
6.3S
Mounting TLA-2
Surface
※4. Prepare the hydraulic lock port on the bottom within the range TLB-2
11 or more
TLA-1
of φ15.
1. Make sure to check the cautions for cylinder mounting distance Link Clamp
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT
982
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ3
φ3
R2 or less
K+0.5 or more
K+0.5 or more
7
2 or less
23
14 14
CD
CB
VFJ-C Notes:
(Cut:One Direction Locating) ※1. Do not use spring washer or toothed lock washer.
1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Datum Diameter Use two jack bolts to remove the product, keeping it
φL g8 parallel to the mounting surface.
φM VFJ-C:Cut 2. This product has no seat. Choose option -B:with Seating
1 3.5
φN
C
◎ φ0.02 X
G
H
※1
B
A
φ19g7 -- 0.028
0.007
5
X
16.5
1-O-ring (Included)
AS568-016 (90° )
983
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
Valve / Coupler
★ Hydraulic Unit
★ Manual Operation
Accessories
★
7.5
★ Cautions / Others
※2 Hole Clamp
Air Blow Port 12.5
SFA
φ3
SFC
Swing Clamp
LHA
⊥ 0.01 Z LHC
Notes: LHS
φ19H7 +0.021
0 30°
Z ※2. Install the air blow port choosing one port from four ★ parts. LHW
Must be 1.3
※3. There might be foam near the flange bottom depending on LT/LG
※3
S
6.3S
6.3
Mounting TLA-2
Surface roughness of mounting surface, but this is not a malfunction.
TLB-2
※4. Prepare the hydraulic lock port on the bottom within the range of TLA-1
17 or more
8
φ19, or within .
Link Clamp
1. Make sure to check the cautions for cylinder mounting distance
LK A
accuracy, workpiece hole distance accuracy and mounting phase LK C
before installation. (Refer to P.1011.) LK W
LM/LJ
※4 T MA - 2
Hydraulic Lock Port
0 ※4 T MA - 1
φ19 -
0.2
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT
C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve
984
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ 2-B
φ3
φWA
M5×0.8×12 R2 or less 2.5°or less
K+0.5 or more
K+0.5 or more
9.5
※1
2 or less
Workpiece Hole Diameter
φWC
45°
45°
BL
FC
O
W
. 24
BB
P.C.D
VFJ-C
(Cut:One Direction Locating)
Notes:
※1. Please note that if the chamfer of the workpiece hole end is
5 Seating Height:H15 large, the seating confirmation air may not be increased.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 VFJ-C:Cut Use two jack bolts to remove the product, keeping it
Steel Ball J φM parallel to the mounting surface.
3.5
◎ φ0.02 X
H±0.03
A
φ15g7 -- 0.006
5
0.024
X 1-O-ring (Included)
10.5
AS568-006 (90° )
1-O-ring (Included)
AS568-013 (90° )
Port Position
R Seating Confirmation Air Hole L
Datum Diameter
φL g8 VFJ-C:Cut
Seating Confirmation Air Port
Steel Ball J φM
Note:
K
φN
C
◎ φ0.02 X
G
H±0.03
A
φ15g7 -- 0.006
5
0.024
X 1-O-ring (Included)
10.5
AS568-006 (90° )
1-O-ring (Included)
AS568-013 (90° )
985
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
Hydraulic Unit
P.C.D 24
. 24 P .C.D.
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※2. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3
LT/LG
※2
S
6.3S
Mounting ※3. Prepare the hydraulic lock port on the bottom within the range
6.3
TLA-2
Surface
of φ15. TLB-2
11 or more
1. Make sure to check the cautions for cylinder mounting distance TLA-1
accuracy, workpiece hole distance accuracy and mounting phase Link Clamp
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT
C 4 4 4 4 4 4 4 4 4 DBC
L 7.5 - 0.005
8.3 - 0.005
9.3 - 0.005 BZL
- 0.027 - 0.027 - 0.027
BZT
M 5.5 6 6.5
BZX/JZG
N 15.5 15.5 15.5 16.5 16.5 16.5 17.5 17.5 17.5
Pallet Clamp
BA 12 13 14
VS
BB 6 6.5 7 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VF J
Weight g 70 80 100 70 80 100 70 80 100
VFK
986
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ 3-B
φ
2-Mounting Bolt (Included) BA 2-M6×1 Thread for Jack Bolt 2.5°or less
37
φWA
M5×0.8×12 R2 or less
K+0.5 or more
K+0.5 or more
11.5
※1
2 or less
Workpiece Hole Diameter
φWC
45°
45°
BL
FC
O
W
. 28
P.C.D
BB
VFJ-C Notes:
(Cut:One Direction Locating) ※1. Please note that if the chamfer of the workpiece hole end is
large, the seating confirmation air may not be increased.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 Use two jack bolts to remove the product, keeping it
φM VFJ-C:Cut parallel to the mounting surface.
3.5
φN
◎ φ0.02 X
C
G
H±0.03
A
φ19g7 -- 0.028
0.007
5
X 1-O-ring (Included)
AS568-006 (90° )
16.5
1-O-ring (Included)
AS568-016 (90° )
Port Position
R Seating Confirmation Air Hole L
Note:
3. Please make sure that the port positions are correct.
987
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
P.C.D 8 Hydraulic Unit
.2
. 28 P.C.D
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ19H7 +0.021
0 30° ※2. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3
LT/LG
※2
S
6.3S
※3. Prepare the hydraulic lock port on the bottom within the range of
6.3
Mounting TLA-2
Surface
φ19, or within . TLB-2
1. Make sure to check the cautions for cylinder mounting distance TLA-1
17 or more
8
accuracy, workpiece hole distance accuracy and mounting phase Link Clamp
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 DBC
L 10.2 -- 0.006 11.2 -- 0.006 12.0 -- 0.006 13.0 -- 0.006 13.8 -- 0.006 BZL
0.033 0.033 0.033 0.033 0.033
BZT
M 7.4 8.4 9.2 10.2 11.0
BZX/JZG
N 19.5 19.5 19.5 20.5 20.5 20.5 21.5 21.5 21.5 22.5 22.5 22.5 23.5 23.5 23.5
Pallet Clamp
BA 15 16 17 17 18
VS
BB 8 8.5 9 9.5 10 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL
988
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ2-M
φ3
φWA
M5×0.8×12 R2 or less 2.5°or less
K+0.5 or more
K+0.5 or more
T
35°
EX
9.5
2 or less
Workpiece Hole Diameter
φWC
45°
45°
R
BL
O
NS
O
W
SE
. 24
P.C.D
VFJ-C
(Cut:One Direction Locating)
Notes:
1. When mounting the product, use two mounting bolts
5 Seating Height:H15 (Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
Datum Diameter parallel to the mounting surface.
φL g8 VFJ-C:Cut 2. The port name is marked on the product surface.
Steel Ball J φM (EXT:Air Vent Port, BLOW:Air Blow Port,
3.5
◎ φ0.02 X
1
H
B
F
A
φ15g7 -- 0.006
5
0.024
X
16
1-O-ring (Included)
AS568-013 (90° )
Port Position
R Air Vent Port L
Datum Diameter
φL g8 VFJ-C:Cut
Release Confirmation Air Port
Steel Ball J φM
Note:
K
3.5
φN
C
◎ φ0.02 X
1
G
H
B
A
φ15g7 -- 0.006
5
0.024
X
16
1-O-ring (Included)
AS568-013 (90° )
989
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Air Vent Port 2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more Air Vent Port Hydraulic Series
φ3 φ3
Valve / Coupler
Hydraulic Unit
35°
P.C.D 24
35°
. 24 P .C.D.
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※1. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3
LT/LG
※1
S
6.3S
Mounting ※2. Prepare the hydraulic lock port on the bottom within the range
6.3
TLA-2
Surface
of φ15. TLB-2
TLA-1
16.5 or more
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT
990
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ3-M
φ
2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt φWA 2.5°or less
37
M5×0.8×12 R2 or less
K+0.5 or more
K+0.5 or more
T
EX
35°
11.5
2 or less
Workpiece Hole Diameter
φWC
45°
45°
R
BL
O
NS
O
W
SE
. 28
P.C.D
VFJ-C Notes:
(Cut:One Direction Locating) 1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
Datum Diameter parallel to the mounting surface.
φL g8 2. The port name is marked on the product surface.
φM VFJ-C:Cut (EXT:Air Vent Port, BLOW:Air Blow Port,
φN
C
◎ φ0.02 X
G
H
B
F
A
4
7.5
φ19g7 -- 0.007
0.028
X
1-O-ring (Included)
24
AS568-016 (90° )
Port Position
R Air Vent Port L
Note:
4. Please make sure that the port positions are correct.
991
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Valve / Coupler
P.C.D Hydraulic Unit
35°
28
35°
. 28 P.C.D.
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ19H7 +0.021
0 30° ※1. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3
LT/LG
※1
S
※2. Prepare the hydraulic lock port on the bottom within the range of
6.3S
6.3
Mounting TLA-2
Surface
φ19, or within . TLB-2
1. Make sure to check the cautions for cylinder mounting distance TLA-1
10.5
Link Clamp
before installation. (Refer to P.1011.) LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
※2 Work Support
Hydraulic Lock Port
0 ※2 LD
φ19 -
0.2
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT
C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve
992
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK
VFK 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7
1 Body Size
2 Design No.
0 :Revision Number
Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150
Workpiece Hole Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8 φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
Diameter (mm) Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8 φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
VFK2000 Selection Range
VFK3000 Selection Range
4 Functions
Datum Cut
5 Seating Height
H15 :15mm
Seating Height
Note:
H20 :20mm
Prepare the seat separately for 6 Option Blank:Standard
H25 :25mm and M:Release Confirmation Model.
993
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Series
Pneumatic Series
Hydraulic Series
Valve / Coupler
Hydraulic Unit
Manual Operation
Accessories
7 Port Position Only for 6 Options:B (with Seating Surface), and M (Release Confirmation Model) LHW
LT/LG
R Vent Port Vent Port L TLA-2
R :As Illustrated TLB-2
Only for 6 M Only for 6 M TLA-1
L :As Illustrated
Link Clamp
LK A
Air Blow Port Air Blow Port LK C
LK W
Air Port Air Port LM/LJ
6 B :Seating Confirmation 6 B :Seating Confirmation T MA - 2
T MA - 1
6 M:Release Confirmation 6 M:Release Confirmation
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VFL
VFM
VFJ
VF K
994
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK
Specifications:VFK2000
Model No. VFK2000-080 VFK2000-090 VFK2000-100
Workpiece Hole Diameter Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8
mm Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.4 ±0.4 ±0.5
at 1.5MPa 50
Expanding Force (F) ※2
at 5.0MPa 150
N
at 7.0MPa 210
Allowable Thrust Load ※3 N 450 600 800
Cylinder Capacity Release side 0.03 0.04 0.04
(Empty Action) cm3 Lock side 0.08 0.10 0.12
Operating Pressure Range MPa 1.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32
Specifications:VFK3000
Model No. VFK3000-110 VFK3000-120 VFK3000-130 VFK3000-140 VFK3000-150
Workpiece Hole Diameter Straight Hole φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
mm Taper Hole φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.6 ±0.6 ±0.7 ±0.7 ±0.8
at 1.5MPa 100
Expanding Force (F) ※2
at 5.0MPa 330
N
at 7.0MPa 460
Allowable Thrust Load ※3 N 1000 1000 1300 1300 1800
Cylinder Capacity Release side 0.11 0.11 0.13 0.13 0.15
(Empty Action) cm3 Lock side 0.29 0.29 0.32 0.32 0.36
Operating Pressure Range MPa 1.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32
Notes:
※1. It shows locating repeatability under the specific condition (no load).
※2. Expanding force shows the calculated value when coefficient friction is μ0.1.
Refer to the next page for the relative equation of expanding force and allowable workpiece weight for locating.
※3. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates and releases with hydraulic pressure. (Hydraulic Pressure Double Action)
2. This cylinder is used only for locating and does not have a clamping function.
995
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating Series
Pneumatic Series
F W
F Hydraulic Series
Horizontal Attitude μ Vertical Attitude
Seat Valve / Coupler
Hydraulic Unit
W
Manual Operation
Accessories
Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5
Workpiece Weight (W) ≦ Workpiece Weight (W) ≦ Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5 Cautions / Others
Friction Coefficient of Workpiece Seat Face (μ)
Hole Clamp
SFA
SFC
Swing Clamp
LHA
LHC
LHS
LHW
LT/LG
TLA-2
TLB-2
TLA-1
Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VFL
VFM
VFJ
VF K
996
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Hyd. Release model VFK2
φ3
φWA
M5×0.8×12 R2 or less 2.5°or less
K+0.5 or more
K+0.5 or more
19
2 or less
Workpiece Hole Diameter
φWC
12 12
VFK-C
(Cut:One Direction Locating)
Notes:
※1. Set the O-ring to the mounting hole side (fixture side)
5 Seating Height:H15 before mounting the body.
※2. Do not use spring washer or toothed lock washer.
Datum Diameter 1. When mounting the product, use two mounting bolts
φL g8 VFK-C:Cut (Strength Grade 12.9) and tighten them evenly.
Steel Ball J φM Use two jack bolts to remove the product, keeping it
3.5
G φN
C
◎ φ0.02 X
1
※2
H
B
F
A
φ15g7 -- 0.006
5
0.024
X
18.5
1-O-ring (Included)
AS568-013 (90° )
※1
1-O-ring (Included)
AS568-013 (90° )
Datum Diameter
φL g8 VFK-C:Cut
Steel Ball J φM
60°
K
E
3.5
φN
C
◎ φ0.02 X
1
G
H
※2
B
A
φ15g7 -- 0.006
5
0.024
X
18.5
1-O-ring (Included)
AS568-013 (90° )
※1
1-O-ring (Included)
AS568-013 (90° )
997
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
★ ★ Cautions / Others
※3
Air Blow Port 10.5 Hole Clamp
φ3 SFA
SFC
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※3. Install the air blow port choosing one port from four ★ parts.
Z LHW
※4. There might be foam near the flange bottom depending on
Must be 1.3
LT/LG
※4
S
6.3S
Mounting TLA-2
Surface
※5. Prepare the hydraulic lock port on the bottom within the range TLB-2
TLA-1
of φ12.1.
7.5
19 or more
Link Clamp
※6
LK C
accuracy, workpiece hole distance accuracy and mounting phase
LK W
before installation. (Refer to P.1011.) LM/LJ
T MA - 2
※6 ※5
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※5
φ12.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT
998
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Hyd. Release model VFK3
φ3
R2 or less
K+0.5 or more
K+0.5 or more
7
23
2 or less
Workpiece Hole Diameter
φWC
14 14
CD
CB
VFK-C Notes:
(Cut:One Direction Locating) ※1. Set the O-ring to the mounting hole side (fixture side)
before mounting the body.
※2. Do not use spring washer or toothed lock washer.
Datum Diameter 1. When mounting the product, use two mounting bolts
φL g8 (Strength Grade 12.9) and tighten them evenly.
φM VFK-C:Cut Use two jack bolts to remove the product, keeping it
1 3.5
φN
C
◎ φ0.02 X
G
H
※2
B
A
φ19g7 -- 0.028
0.007
5
X
18.5
1-O-ring (Included)
AS568-016 (90° )
※1
1-O-ring (Included)
AS568-016 (90° )
999
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Pneumatic Series
Valve / Coupler
★ Hydraulic Unit
★ Manual Operation
Accessories
★
7.5
★ Cautions / Others
※3 Hole Clamp
Air Blow Port 12.5
SFA
φ3
SFC
Swing Clamp
LHA
⊥ 0.01 Z LHC
Notes: LHS
φ19H7 +0.021
0 30°
Z ※3. Install the air blow port choosing one port from four ★ parts. LHW
Must be 1.3
※4. There might be foam near the flange bottom depending on LT/LG
※4
S
6.3S
6.3
Mounting TLA-2
Surface roughness of mounting surface, but this is not a malfunction.
TLB-2
※5. Prepare the hydraulic lock port on the bottom within the range TLA-1
7.5
of φ16.1.
19 or more
17±0.1
Link Clamp
※6. Prepare the hydraulic release port within .
※6
LK A
1. Make sure to check the cautions for cylinder mounting distance
7
LK C
accuracy, workpiece hole distance accuracy and mounting phase LK W
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT
C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve
1000
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK 2-B
φ3
φWA
M5×0.8×12 R2 or less 2.5°or less
K+0.5 or more
K+0.5 or more
9.5
※2
2 or less
Workpiece Hole Diameter
φWC
45°
45°
BL
FC
O
W
. 24
BB
P.C.D
VFK-C
(Cut:One Direction Locating)
Notes:
※1. Set the O-ring to the mounting hole side (fixture side)
5 Seating Height:H15 before mounting the body.
※2. Please note that if the chamfer of the workpiece hole end is
Datum Diameter large, the seating confirmation air may not be increased.
φL g8 VFK-C:Cut 1. When mounting the product, use two mounting bolts
Steel Ball J φM (Strength Grade 12.9) and tighten them evenly.
3.5
◎ φ0.02 X Continuously supply air pressure to the air blow port and
H±0.03
φ15g7 -- 0.006
5
0.024
X 1-O-ring (Included)
AS568-006 (90° )
18.5
1-O-ring (Included)
AS568-013 (90° )
※1
Port Position
1-O-ring (Included)
AS568-013 (90° ) R Seating Confirmation Air Hole L
Datum Diameter
φL g8 VFK-C:Cut
Seating Confirmation Air Port
Steel Ball J φM
Note:
K
φN
C
◎ φ0.02 X
G
H±0.03
A
φ15g7 -- 0.006
5
0.024
X 1-O-ring (Included)
AS568-006 (90° )
18.5
1-O-ring (Included)
AS568-013 (90° )
※1
1-O-ring (Included)
AS568-013 (90° )
1001
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
Hydraulic Unit
P.C.D 24
. 24 P .C.D.
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※3. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3
LT/LG
※3
S
6.3S
Mounting ※4. Prepare the hydraulic lock port on the bottom within the range
6.3
TLA-2
Surface
of φ12.1. TLB-2
19 or more
Link Clamp
※5
LK C
before installation. (Refer to P.1011.)
LK W
LM/LJ
T MA - 2
※5 ※4
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※4
φ12.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT
C 4 4 4 4 4 4 4 4 4 DBC
L 7.5 - 0.005
8.3 - 0.005
9.3 - 0.005 BZL
- 0.027 - 0.027 - 0.027
BZT
M 5.5 6 6.5
BZX/JZG
N 15.5 15.5 15.5 16.5 16.5 16.5 17.5 17.5 17.5
Pallet Clamp
BA 12 13 14
VS
BB 6 6.5 7 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VFJ
Weight g 80 90 110 80 90 110 80 90 110
VF K
1002
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK 3-B
φ
2-Mounting Bolt (Included) BA 2-M6×1 Thread for Jack Bolt 2.5°or less
37
φWA
M5×0.8×12 R2 or less
K+0.5 or more
K+0.5 or more
11.5
※2
2 or less
Workpiece Hole Diameter
φWC
45°
45°
BL
FC
O
W
. 28
P.C.D
BB
VFK-C Notes:
(Cut:One Direction Locating) ※1. Set the O-ring to the mounting hole side (fixture side)
before mounting the body.
※2. Please note that if the chamfer of the workpiece hole end is
Datum Diameter large, the seating confirmation air may not be increased.
φL g8 1. When mounting the product, use two mounting bolts
φM VFK-C:Cut (Strength Grade 12.9) and tighten them evenly.
G
H±0.03
A
φ19g7 -- 0.028
0.007
5
X 1-O-ring (Included)
AS568-006 (90° )
18.5
1-O-ring (Included)
AS568-016 (90° )
Port Position
※1
1-O-ring (Included)
AS568-016 (90° )
R Seating Confirmation Air Hole L
Note:
3. Please make sure that the port positions are correct.
1003
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
P.C.D 8 Hydraulic Unit
.2
. 28 P.C.D
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ19H7 +0.021
0 30° ※3. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3
LT/LG
※3
S
6.3S
Mounting ※4. Prepare the hydraulic lock port on the bottom within the range
6.3
TLA-2
Surface
of φ16.1. TLB-2
19 or more
17±0.1
1. Make sure to check the cautions for cylinder mounting distance Link Clamp
※5
LK C
before installation. (Refer to P.1011.)
LK W
LM/LJ
T MA - 2
※5 ※4
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※4
φ16.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 DBC
L 10.2 -- 0.006 11.2 -- 0.006 12.0 -- 0.006 13.0 -- 0.006 13.8 -- 0.006 BZL
0.033 0.033 0.033 0.033 0.033
BZT
M 7.4 8.4 9.2 10.2 11.0
BZX/JZG
N 19.5 19.5 19.5 20.5 20.5 20.5 21.5 21.5 21.5 22.5 22.5 22.5 23.5 23.5 23.5
Pallet Clamp
BA 15 16 17 17 18
VS
BB 8 8.5 9 9.5 10 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL
1004
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK 2-M
φ3
φWA
M5×0.8×12 R2 or less 2.5°or less
K+0.5 or more
K+0.5 or more
T
35°
EX
9.5
2 or less
Workpiece Hole Diameter
φWC
45°
45°
R
BL
O
NS
O
W
SE
. 24
P.C.D
VFK-C
(Cut:One Direction Locating)
Notes:
※1. Set the O-ring to the mounting hole side (fixture side)
5 Seating Height:H15 before mounting the body.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 VFK-C:Cut Use two jack bolts to remove the product, keeping it
Steel Ball J φM parallel to the mounting surface.
3.5
◎ φ0.02 X
1
- 0.006
φ15g7
5
- 0.024
X
18.5
1-O-ring (Included)
AS568-013 (90° )
1-O-ring (Included)
※1 Port Position
AS568-013 (90° )
R Air Vent Port L
Datum Diameter
φL g8 VFK-C:Cut
Release Confirmation Air Port
Steel Ball J φM
Note:
K
3.5
φN
C
◎ φ0.02 X
1
G
H
B
A
φ15g7 -- 0.006
5
0.024
X
18.5
1-O-ring (Included)
AS568-013 (90° )
※1
1-O-ring (Included)
AS568-013 (90° )
1005
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Air Vent Port 2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more Air Vent Port Hydraulic Series
φ3 φ3
Valve / Coupler
Hydraulic Unit
P.C.D 24
35°
.C.D.
35°
. 24 P
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
※2. There might be foam near the flange bottom depending on LHS
φ15H7 +0.018
0 30°
Z roughness of mounting surface, but this is not a malfunction.
LHW
Must be 1.3
LT/LG
※2
※3. Prepare the hydraulic lock port on the bottom within the
S
6.3S
Mounting
6.3
TLA-2
Surface
range of φ12.1. TLB-2
※4. Prepare the hydraulic release port within . TLA-1
7.5
19 or more
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
※4
LK A
before installation. (Refer to P.1011.)
7
LK C
LK W
LM/LJ
T MA - 2
※4 ※3
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※3
φ12.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT
1006
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Hyd. Release model VFK3-M
φ
2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt 2.5°or less
37
φWA
M5×0.8×12
R2 or less
K+0.5 or more
K+0.5 or more
T
EX
35°
11.5
2 or less
Workpiece Hole Diameter
φWC
45°
45°
R
BL
O
NS
O
W
SE
. 28
P.C.D
VFK-C Notes:
(Cut:One Direction Locating) ※1. Set the O-ring to the mounting hole side (fixture side)
before mounting the body.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 Use two jack bolts to remove the product, keeping it
φM VFK-C:Cut parallel to the mounting surface.
◎ φ0.02 X
G Surface or prepare another seat if necessary.
H
B
A
4
7.5
φ19g7 -- 0.007
0.028
X
21
1-O-ring (Included)
AS568-016 (90° )
Port Position
※1
1-O-ring (Included)
AS568-016 (90° )
R Air Vent Port L
Note:
4. Please make sure that the port positions are correct.
1007
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009
High-Power
Machining Dimensions for Mounting Series
Valve / Coupler
P.C.D Hydraulic Unit
28
35°
.C.D.
35°
. 28 P
Manual Operation
Accessories
Cautions / Others
45°
45°
45°
45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
※2. There might be foam near the flange bottom depending on LHS
φ19H7 +0.021
0 30°
Z roughness of mounting surface, but this is not a malfunction.
LHW
Must be 1.3
LT/LG
※2
※3. Prepare the hydraulic lock port on the bottom within the
S
6.3S
Mounting
6.3
TLA-2
Surface
range of φ16.1. TLB-2
※4. Prepare the hydraulic release port within . TLA-1
10
21.5 or more
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase LK A
※4
LK W
LM/LJ
T MA - 2
T MA - 1
※4 ※3
Hydraulic Release Port Hydraulic Lock Port
※3
Work Support
φ16.1±0.05
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT
C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve
1008
Expansion Locating Pin Cautions m od e l VFL/VFM/VFJ/ V F K
Cautions
Clearance
piece
lar
cu Expanding Direction
di
Seating Height
Spacer
en
Y
Perp
(Prepared by Customer)
X
max. 3
lar ● Install a spacer block under the flange if the height of expansion
cu Expanding Direction
di locating pin is not enough.
en
Y
Perp
Expanding Direction
1009
Expansion Locating Pin
Cautions
Digest P.937
High-Power
Series
Pneumatic Series
8)When the workpiece is in vertical position. 9)Inclination in the Z-axis direction. Hydraulic Series
● When setting a workpiece, make sure it is in proper proximity and ● If a workpiece is tilted when loading/unloading, expanded part
Valve / Coupler
square to the expansion locating pins. of expansion locating pin and workpiece hole will get stuck and Hydraulic Unit
If it is locked out of position, the products may be damaged. the cylinder and workpiece will be damaged. Workpiece should be
Manual Operation
● As the workpiece may fall down during releasing, it is recommended loaded and unloaded with less than 4/100 5/100 (approx. 2 3°
) Accessories
to set up the latching mechanism to prevent it from falling down. of tilt between workpiece and expansion locating pin plane.
Cautions / Others
● When the workpiece is used in vertical position (hanging on the wall), ● If necessary, provide guide pins to keep the workpiece level during
the internal moving parts tend to wear out. Check the locating accuracy loading and unloading. Please prepare guide pin (rough guide) etc.
regularly, and if exceeding the allowable range, replace the product. Hole Clamp
SFA
Workpiece
SFC
Example of Latching Mechanism
Swing Clamp
LHA
LHC
LHS
LHW
Expansion Locating Pin LT/LG
TLA-2
TLB-2
TLA-1
Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
Guide Pin
T MA - 1
(Rough Guide)
Work Support
LD
10)Thickness around the Workpiece Hole
LC
● Thin wall around the workpiece hole could be deformed by T NC
expanding force, and locating accuracy would not fill the TC
Air Sensing
specification. Please conduct trial testing and adjust to proper Lift Cylinder
hydraulic pressure before use. LLW
Compact Cylinder
LL
LLR
LLU
Deformation
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
Expansion
Locating Pin
VF L
VF M
VF J
VF K
1010
Expansion Locating Pin Cautions m od e l VFL/VFM/VFJ/ V F K
Cautions
● Notes for Design Regarding to VFL / VFM ● Notes for Design Regarding to VFJ / VFK
Workpiece
Base Plate
1011
Expansion Locating Pin
Cautions
Digest P.937
High-Power
Series
Pneumatic Series
● Installation Notes
1)Usable Fluid 5)Appropriate Measures for the Air Vent Port Hydraulic Series
● Please use the appropriate fluid by referring to the Hydraulic ● For the air vent port of -M:Release Confirmation model,
Valve / Coupler
Fluid List (P.1237). consider the environment and avoid coolant or any contaminants. Hydraulic Unit
If coolant or contaminants enter in the product, it will not function
Manual Operation
2)Procedure before Piping properly. Accessories
● The pipeline, piping connector and fixture circuits should be
Cautions / Others
cleaned and flushed thoroughly.
The dust and cutting chips in the circuit may lead to fluid leakage
and malfunction. Hole Clamp
SFA
SFC
3)Applying Sealing Tape
Swing Clamp
● Wrap with tape 1 to 2 times following the screwing direction.
LHA
Wrapping in the wrong direction will cause leaks and malfunction. Examples LHC
● Pieces of the sealing tape can lead to oil leaks and malfunction. ① Prepare the manifold piping. LHS
LHW
● When piping, be careful that contaminant such as sealing tape Use the manifold piping and prepare the air vent port to
LT/LG
does not enter in products. the place without the influence of coolant or cutting chips. TLA-2
TLB-2
● Use all bolts with hex holes (Strength Grade 12.9) and tighten Link Clamp
LK A
them with a torque wrench as shown in the table below.
LK C
Tighten them evenly to prevent twisting or jamming. LK W
LM/LJ
Model No. Thread Size Tightening Torque (N・m)
T MA - 2
VFL2000 M5×0.8 6.3
T MA - 1
VFL3000 M5×0.8 6.3
Work Support
VFL4000 M6×1 10 ② Prepare the external piping.
VFL5000 M6×1 10 LD
If it is impossible to prepare manifold piping like the case ①,
LC
VFL6000 M8×1.25 25
move the air vent port by using external piping to the place T NC
VFM2000 M5×0.8 6.3
VFM3000 M5×0.8 6.3
without the influence of coolant or any contaminants. TC
Air Sensing
VFM4000 M6×1 10 Lift Cylinder
VFM5000 M6×1 10 LLW
VFM6000 M8×1.25 25
Compact Cylinder
VFJ2000 M5×0.8 6.3
LL
VFJ3000 M5×0.8 6.3
LLR
VFK2000 M5×0.8 6.3
LLU
VFK3000 M5×0.8 6.3
DP
DR
● Do not use spring washer or toothed lock washer. DS
DT
● There might be foam near the flange bottom depending on
roughness of mounting surface, but this is not a malfunction. 6)Installation of O-ring (Included) Block Cylinder
DBA
● When removing the product, use two jack bolts (two mounting bolt ● For VFL / VFM (VFM2000 / VFM3000 / VFM4000) / VFK,
DBC
holes) in order not to damage the installation tap. The below picture set the O-ring to the mounting hole side (fixture side)
Centering Vise
shows the case in which the parallel pin (hollow set) is set in the before mounting the body.
FVA
tapped hole so that the installation tap will not be damaged.
FVD
FVC
Pallet Clamp
VS
VT
1012
Expansion Locating Pin Cautions model VFL/V F M
Circuit Reference
● Notes on Hydraulic Cylinder Speed Control Circuit VFL (Standard) VFL-B (with Seating Surface) VFL-M (Release Confirmation Model)
Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance.
Circuit Reference
※2
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator
VFL
※2
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Single Action Releases with Hydraulic Pressure Release Hydraulic Pressure
Pressure
※1
model VFL
Expansion Locating Pin and Recommended Air Pressure
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow
Air
the same circuit.
VFL-C VFL-D Filter 5μm
(Cut) (Datum)
※3
Single-Action Actuator Double-Action Actuator
VFL-B
※2
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Releases with Hydraulic Pressure Release Hydraulic Pressure Pressure
※1
※3
Single-Action Actuator Double-Action Actuator
VFL-M
※2
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Releases with Hydraulic Pressure Release Hydraulic Pressure Pressure
※1
Notes:
※1. The procedure for lock operation should be "VFL (Expansion Locating Pin)" → "other actuators".
Otherwise there might be accuracy failure and/or damages on the product.
※2. Use the check valve (Recommended cracking pressure:0.04MPa or less) if there is back pressure in the tank port.
※3. Adjust the flow rate so that there is no surge pressure.
※4. Recommended Air Sensor:ISA□-G (SMC), GPS3 (CKD)
1. This circuit reference is one example. It should be prepared depending on the fixture structure.
1013
Expansion Locating Pin
Cautions
Digest P.937
High-Power
Series
Pneumatic Series
● Notes on Hydraulic Cylinder Speed Control Circuit VFM (Standard) VFM-B (with Seating Surface) VFM-M (Release Confirmation Model)
Hydraulic Series
Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit
Circuit Reference
Manual Operation
Accessories
Expansion Locating Pin and Recommended Air Pressure
0.3 ∼ 0.4MPa
other actuators on Air Blow Cautions / Others
Air
different circuits.
VFM-C VFM-D Filter 5μm
(Cut) (Datum)
Hole Clamp
Lock Hydraulic Pressure ※2 SFA
SFC
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator Swing Clamp
VFM LHA
Lock Hydraulic Pressure ※2
Locates and Releases Hydraulic LHC
Double Action with Hydraulic Pressure Release Hydraulic Pressure Pressure LHS
※1 LHW
model VFM LT/LG
Expansion Locating Pin and Recommended Air Pressure
TLA-2
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow TLB-2
Air
the same circuit. TLA-1
VFM-C VFM-D Filter 5μm
(Cut) (Datum) Link Clamp
LK A
Lock Hydraulic Pressure LK C
LK W
Release Hydraulic Pressure
LM/LJ
Single-Action Actuator Double-Action Actuator ※3
VFM T MA - 2
Circuit Reference
● Notes on Hydraulic Cylinder Speed Control Circuit VFJ (Standard) VFJ-B (with Seating Surface) VFJ-M (Release Confirmation Model)
Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance.
Circuit Reference
※3
Single-Action Actuator Double-Action Actuator
VFJ
※2
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Single Action Releases with Spring Release Hydraulic Pressure Pressure
※1
model VFJ
Expansion Locating Pin and Recommended Air Pressure
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow
Air
the same circuit.
VFJ-C VFJ-D Filter 5μm
(Cut) (Datum)
※3
Single-Action Actuator Double-Action Actuator
VFJ-B
※2
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Releases with Spring Release Hydraulic Pressure
Pressure
※1
※3
Single-Action Actuator Double-Action Actuator
VFJ-M
※2
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Releases with Spring Release Hydraulic Pressure
Pressure
※1
Notes:
※1. The procedure for lock operation should be "VFJ (Expansion Locating Pin)" → "other actuators".
Otherwise there might be accuracy failure and/or damages on the product.
※2. Use the check valve (Recommended cracking pressure:0.04MPa or less) if there is back pressure in the tank port.
※3. Adjust the flow rate so that there is no surge pressure.
※4. Recommended Air Sensor:ISA□-G (SMC), GPS3 (CKD)
1. This circuit reference is one example. It should be prepared depending on the fixture structure.
1015
Expansion Locating Pin
Cautions
Digest P.937
High-Power
Series
Pneumatic Series
● Notes on Hydraulic Cylinder Speed Control Circuit VFK (Standard) VFK-B (with Seating Surface) VFK-M (Release Confirmation Model)
Hydraulic Series
Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit
Circuit Reference
Manual Operation
Accessories
Expansion Locating Pin and Recommended Air Pressure
0.3 ∼ 0.4MPa
other actuators on Air Blow Cautions / Others
Air
different circuits.
VFK-C VFK-D Filter 5μm
(Cut) (Datum)
Hole Clamp
Lock Hydraulic Pressure ※2 SFA
SFC
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator Swing Clamp
VFK LHA
Lock Hydraulic Pressure ※2
Locates and Releases Hydraulic LHC
Double Action with Hydraulic Pressure Release Hydraulic Pressure Pressure LHS
※1 LHW
model VFK LT/LG
Expansion Locating Pin and Recommended Air Pressure
TLA-2
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow TLB-2
Air
the same circuit. TLA-1
VFK-C VFK-D Filter 5μm
(Cut) (Datum) Link Clamp
LK A
Lock Hydraulic Pressure LK C
LK W
Release Hydraulic Pressure LM/LJ
Single-Action Actuator Double-Action Actuator ※3
VFK T MA - 2
Cautions
● The pipeline, piping connector and fixture circuits should be cleaned JX Nippon Oil & Energy Super Hyrando 32 Super Mulpus DX 32
Cosmo Oil Cosmo Hydro AW32 Cosmo New Mighty Super 32
by thorough flushing.
ExxonMobil Mobil DTE 24 Mobil DTE 24 Light
● The dust and cutting chips in the circuit may lead to fluid leakage
Matsumura Oil Hydol AW-32
and malfunction.
Castrol Hyspin AWS 32
● There is no filter provided with Kosmek s product except for a part
Note As it may be difficult to purchase the products as shown in the table from
of valves which prevents foreign materials and contaminants from
overseas, please contact the respective manufacturer.
getting into the circuit.
1237
Installation Notes Notes on Hydraulic Cylinder
Hydraulic Fluid List Notes on Handling Maintenance/Inspection Warranty
(For Hydraulic Series) Speed Control Circuit
High-Power
Series
Pneumatic Series
● Notes on Hydraulic Cylinder Speed Control Unit
Please pay attention to the cautions below. Design the hydraulic circuit for controlling the action speed of hydraulic cylinder.
!
Hydraulic Series
Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit
● Flow Control Circuit for Single Acting Cylinder In the case of meter-out circuit, the hydraulic circuit should Manual Operation
For spring return single acting cylinders, restricting flow be designed with the following points. Accessories
during release can extremely slow down or disrupt release action. ① Single acting components should not be used in the same
Cautions / Others
The preferred method is to control the flow during the lock action flow control circuit as the double acting components.
using a valve that has free-flow in the release direction. The release action of the single acting cylinders may become
It is also preferred to provide a flow control valve at each actuator. erratic or very slow.
Cautions
Installation Notes
(For Hydraulic Series)
Hydraulic Fluid List
Maintenance/
Inspection
Accelerated clamping speed by excessive hydraulic flow to
Warranty
the cylinder may sustain damage. In this case add flow control to
regulate flow. (Please add flow control to release flow if the
lever weight is put on at the time of release action when using Refer to the following circuit when both the single acting Company Profile
cylinder and double acting cylinder are used together. Company Profile
swing clamps.)
○ Separate the control circuit. Our Products
Flow Control at the Release Side
History
Index
Search by
Alphabetical Order
W Sales Offices
② In the case of meter-out circuit, the inner circuit pressure may
increase during the cylinder action because of the fluid supply.
The increase of the inner circuit pressure can be prevented by
reducing the supplied fluid beforehand via the flow control valve.
Especially when using sequence valve or pressure switches for
clamping detection. If the back pressure is more than the set
pressure then the system will not work as it is designed to.
Sequence Valve
1238
Cautions
Cautions
1)It should be handled by qualified personnel. 1)Removal of the Machine and Shut-off of Pressure Source
● The hydraulic machine and air compressor should be handled ● Before the machine is removed, make sure that the
and maintained by qualified personnel. above-mentioned safety measures are in place. Shut off the
2)Do not handle or remove the machine unless the safety protocols air of hydraulic source and make sure no pressure exists in
are ensured. the hydraulic and air circuit.
① The machine and equipment can only be inspected or prepared ● Make sure there is no abnormality in the bolts and respective
when it is confirmed that the preventive devices are in place. parts before restarting.
② Before the machine is removed, make sure that the above-mentioned
safety measures are in place. Shut off the air of hydraulic source 2)Regularly clean the area around the piston rod and plunger.
and make sure no pressure exists in the hydraulic and air circuit. ● If it is used when the surface is contaminated with dirt, it may
③ After stopping the machine, do not remove until the temperature lead to packing seal damage, malfunctioning, fluid leakage
cools down. and air leaks.
④ Make sure there is no abnormality in the bolts and respective parts
before restarting the machine or equipment.
1239
Installation Notes Notes on Hydraulic Cylinder
Hydraulic Fluid List Notes on Handling Maintenance/Inspection Warranty
(For Hydraulic Series) Speed Control Circuit
High-Power
Series
Pneumatic Series
● Warranty
Manual Operation
2)Warranty Scope Accessories
● If the product is damaged or malfunctions during the warranty
Cautions / Others
period due to faulty design, materials or workmanship, we will
replace or repair the defective part at our expense.
Defects or failures caused by the following are not covered.
Cautions
Installation Notes
① If the stipulated maintenance and inspection are not carried out. (For Hydraulic Series)
② If the product is used while it is not suitable for use based on Hydraulic Fluid List
1240
Company Profile
Sales Offices
Sales Offices across the World
Japan TEL. +81-78-991-5162 FAX. +81-78-991-8787
KOSMEK LTD. 1-5, 2-chome, Murotani, Nishi-ku, Kobe-city, Hyogo, Japan 651-2241
Overseas Sales
〒651-2241 兵庫県神戸市西区室谷2丁目1番5号
Taiwan
(Taiwan Exclusive Distributor)
TEL. +886-2-82261860 FAX. +886-2-82261890
Full Life Trading Co., Ltd. 16F-4, No.2, Jian Ba Rd., Zhonghe District, New Taipei City Taiwan 23511
盈生貿易有限公司 台湾新北市中和區建八路2號 16F- 4(遠東世紀廣場)
Philippines
(Philippines Exclusive Distributor)
TEL. +63-2-310-7286 FAX. +63-2-310-7286
G.E.T. Inc, Phil. Victoria Wave Special Economic Zone Mt. Apo Building, Brgy. 186, North Caloocan City, Metro Manila, Philippines 1427
Indonesia
(Indonesia Exclusive Distributor)
TEL. +62-21-29628607 FAX. +62-21-29628608
PT. Yamata Machinery Delta Commercial Park I, Jl. Kenari Raya B-08, Desa Jayamukti, Kec. Cikarang Pusat Kab. Bekasi 17530 Indonesia
Europe
Canada
U.S.A.
Asia
Mexico
Brazil
Australia
Korea
Japan
China
Taiwan
India
Thailand Philippines
Malaysia
Singapore
Indonesia
● FOR FURTHER INFORMATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US. JQA-QMA10823
KOSMEK HEAD OFFICE
● SPECIFICATIONS IN THIS CATALOG ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Company Profile
Sales Offices
Sales Offices across the World
Japan TEL. +81-78-991-5162 FAX. +81-78-991-8787
KOSMEK LTD. 1-5, 2-chome, Murotani, Nishi-ku, Kobe-city, Hyogo, Japan 651-2241
Overseas Sales
〒651-2241 兵庫県神戸市西区室谷2丁目1番5号
Taiwan
(Taiwan Exclusive Distributor)
TEL. +886-2-82261860 FAX. +886-2-82261890
Full Life Trading Co., Ltd. 16F-4, No.2, Jian Ba Rd., Zhonghe District, New Taipei City Taiwan 23511
盈生貿易有限公司 台湾新北市中和區建八路2號 16F- 4(遠東世紀廣場)
Philippines
(Philippines Exclusive Distributor)
TEL. +63-2-310-7286 FAX. +63-2-310-7286
G.E.T. Inc, Phil. Victoria Wave Special Economic Zone Mt. Apo Building, Brgy. 186, North Caloocan City, Metro Manila, Philippines 1427
Indonesia
(Indonesia Exclusive Distributor)
TEL. +62-21-29628607 FAX. +62-21-29628608
PT. Yamata Machinery Delta Commercial Park I, Jl. Kenari Raya B-08, Desa Jayamukti, Kec. Cikarang Pusat Kab. Bekasi 17530 Indonesia
Europe
Canada
U.S.A.
Asia
Mexico
Brazil
Australia
Korea
Japan
China
Taiwan
India
Thailand Philippines
Malaysia
Singapore
Indonesia
● FOR FURTHER INFORMATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US. JQA-QMA10823
KOSMEK HEAD OFFICE
● SPECIFICATIONS IN THIS CATALOG ARE SUBJECT TO CHANGE WITHOUT NOTICE.