You are on page 1of 88

Hydraulic

Expansion Locating Pin


Mode l VFL
Mode l VFM
Mode l VFJ
Mode l VFK

Locating Repeatability VFL/VFM:3μm VFJ/VFK:10μm
Zero Clearance between Reference Hole and Expansion Locating Pin PAT.

Hydraulic expansion locating pin locates workpiece


with high accuracy by expanding and releasing diameter.
Expanding locating pin has zero clearance
The general locating pin has some clearance
between pin and reference hole!!
between pin and reference hole.
High Accuracy, Setup Time and Total Cost Reduction

Workpiece Workpiece

Clearance

Expansion
Locating Pin Locating Pin

The World s First Locating Mechanism


When expanded : Zero clearance between the pin and a workpiece hole
General Locating Pin allows for high accuracy locating.
When released : The pin diameter is retracted so there is enough clearance
for easy loading and unloading of a workpiece.

Action Description
Expansion Locating Pin Object for Locating
General Locating Pin consists of : Round Pin and Diamond Pin.
Kosmek Expansion Locating Pin consists of : Datum Cylinder and
Cut Cylinder.

Reference Locating One Direction Locating


Round Pin Diamond Pin
↓ ↓
< Released State > < Locked State > Datum Cylinder Cut Cylinder

※This drawing shows VFL and VFM.


937
Expansion Locating Pin Cautions
Digest P.1009

Features High-Power
Series
Simple Arrangement Easy to Check the Accuracy For Shallow Workpiece Hole
Pneumatic Series
The compact body can be installed The same core part with X on the flange The low head pin can be used for
close to the clamp, so fixture design top allows to determine the origin and shallow workpiece hole. Hydraulic Series
is more simple. measure the distance accuracy.
Valve / Coupler
Work Clamp Measure the Distance Accuracy Hydraulic Unit
Probe
Expansion Locating Pin Manual Operation

Shallow Hole
Low Head
Accessories

※1
Cautions / Others
◎ φ0.01 X

D C
Hole Clamp
X SFA
Set Close
SFC

※1. It is φ0.02 for VFJ / VFK. Swing Clamp


LHA
Functions LHC
LHS
Air Blow Function With Seating Surface (Seat Check) Release Confirmation LHW
Equipped to All Options Only for -B:With Seating Surface Only for -M:Release Confirmation LT/LG
TLA-2

Air blow prevents foreign substances Seating confirmation is available Release confirmation is available TLB-2

from coming in. by using the gap sensor. by using the gap sensor. TLA-1

Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
※This drawing shows VFL.
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS

Low Pressure DT

Block Cylinder
MAX. 7MPa DBA

Model V FL → P.9 3 9 Mod e l VFM → P. 939 M ode l VFJ → P. 975 M ode l VFK → P. 97 5
DBC

Centering Vise
Type High Accuracy Model Multi-Purpose Model FVA
Locating Repeatability 3μm 10μm FVD
FVC
Single Action Double Action Single Action Double Action
Control Method Control Valve
(Spring Lock/Hydraulic Release) (Hydraulic Lock/Hydraulic Release) (Hydraulic Lock/Spring Release) (Hydraulic Lock/Hydraulic Release)
BZL

Operating Pressure Range 2.5 ∼ 7 MPa 2.5 ∼ 7 MPa 1.5 ∼ 7 MPa BZT
BZX/JZG

Pallet Clamp
Taper Sleeve Steel Ball
VS
VT

Expansion
Locating Pin
VF L
Action
VF M
VF J
VF K
Released State Locked State Released State Locked State
Pull Stud Clamp
FP
Taper sleeve expands. Steel balls come out from the pin.
FQ
Customized
Spring Cylinder
Sample Reference Finishing Line / Dividing Line Locating Casting Core Holes
DW A /DW B

938
Expansion Locating Pin Locating Repeatability:3μm m od e l VFL/V F M

PAT.

Hydrau l ic
Exp ansion L oc atin g P i n
Model VFL/VFM
Hydraulic・Single Action/Double Action

Locating Repeatability:3μm

Index

Expansion Locating Pin Digest P.937

Action Description P.940

System References and Essential Matters P.941

VFL Model No. Indication P.943

VFL Specifications P.945

VFL External Dimensions

・ Standard P.947

・ with Seating Surface P.951

・ Release Confirmation Model P.955

VFM Model No. Indication P.959

VFM Specifications P.961

VFM External Dimensions

・ Standard P.963

・ with Seating Surface P.967

・ Release Confirmation Model P.971

Cautions

・ Notes for Hydraulic Expansion Locating Pin P.1009

・ Cautions (Common) P.1237


・Notes on Hydraulic Cylinder Speed Control Circuit
・Hydraulic Fluid List
・Notes on Handling ・Maintenance/Inspection ・Warranty

939
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Action Description This is a simplified drawing of VFL / VFM (Standard). Series

Pneumatic Series
model VFL model VFM
Hydraulic Series
Phasing Pin
Taper Sleeve Phasing Pin
Taper Sleeve Valve / Coupler
Rod Rod Hydraulic Unit

Manual Operation
Mounting Bolt Body Accessories
Mounting Bolt Body

Cautions / Others

Hole Clamp
SFA
SFC
Air Blow Port
Air Blow Port Swing Clamp
LHA
Spring (for Lock) LHC
Base Plate
Hydraulic Release Port LHS
Piston Hydraulic Lock Port LHW
LT/LG
Base Plate
TLA-2
Hydraulic Release Port Piston
TLB-2
TLA-1

Link Clamp
LK A
About Reference Locating and Orientation LK C
LK W
Cut Mark LM/LJ
Taper Sleeve
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
360°Contact Body Shaft (High Rigidity) Thinned External Surface
TC
Air Sensing
Lift Cylinder
VFL/VFM -D:Datum V FL /V FM - C: Cut
LLW
Reference Locating One Direction Locating
Compact Cylinder
LL
model VFL model VFM LLR
LLU
DP
Workpiece Workpiece
・VFL:When release hydraulic pressure is ON, the taper sleeve DR

ascends with piston/rod and shrinks with its own elasticity. DS


DT
・VFM:When lock hydraulic pressure is OFF and release Seating
Seating hydraulic pressure is ON, the taper sleeve ascends with Block Cylinder
DBA
piston/rod and shrinks with its own elasticity.
DBC
・Air blow prevents debris contamination.
・Rod head and taper sleeve are designed to load/unload Centering Vise

workpiece smoothly and prevent scratches. FVA


Air Blow
Air Blow FVD
ON
ON FVC

Base Plate Release Hydraulic Pressure When loading workpiece When unloading workpiece Control Valve
Lock Hydraulic
ON Pressure OFF BZL
Base Plate Release Hydraulic Pressure BZT
ON BZX/JZG

Pallet Clamp
VS
VT
When locating Expansion
Locating Pin
VF L
・VFL:When release hydraulic pressure is OFF, VF M
VFJ
the piston/rod descend and the taper sleeve is expanded
VFK
to locate the workpiece with high accuracy.
・VFM:When release hydraulic pressure is OFF and lock hydraulic Pull Stud Clamp
Air Blow
pressure is ON, the piston/rod descend and the taper sleeve FP
ON
FQ
is expanded to locate the workpiece with high accuracy.
Air Blow Customized
ON (Seating is required for standard and release confirmation Spring Cylinder
Lock Hydraulic
models.) Pressure ON DW A /DW B
Release Hydraulic Pressure
Release Hydraulic Pressure
OFF
OFF 940
Expansion Locating Pin Locating Repeatability:3μm model VFL/V F M

System References

● Repeated locating accuracy of 3μm ( One step locating reduces setup time! )

● Avoid deterioration of workpiece accuracy when changing pallets to perform multiple operations.

● Using with hole clamp allows for 5-face machining, minimum setup and more compact fixture!

2 4 3 4
model VFL/VFM-D model VFL/VFM-C
Expansion Locating Pin (Equivalent to Round Pin) Expansion Locating Pin (Equivalent to Diamond Pin)

5 6

Work Clamp
(Hole Clamp)

1 4

Hole for Locating (2 required)


Rough Guide
(φ8 φ30:Hole Machining Accuracy H8 or better)

Workpiece (Pallet)

Base Plate

Application Examples

Workpiece Jig Fixture Plate

Enough
Clearance

Base Plate Base Plate

Suitable for Automation with


Workpiece Location Angle Plate Fixture Plate Location
Enough Clearance for Loading/Unloading

941
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Essential Points Series

Workpiece Hole Diameter Pneumatic Series

1 Workpiece Hole for Locating φ8 ∼φ30H8


Hydraulic Series
・Workpiece hole diameter is φ8∼φ30 (in 1mm increments).
Valve / Coupler
・ Hole machining accuracy for locating hole (two holes) is H8 or better.
Hydraulic Unit

Manual Operation
Accessories

2 Workpiece Weight Cautions / Others

・Workpiece weight that expansion locating pin is able to locate with


Expanding Hole Clamp
is calculated from expanding force. Force Maximum workpiece weight is SFA
calculated from expanding force. SFC
・ Expanding force is the force with which the expansion locating pin
Swing Clamp
pushes out (expands) against the workpiece. LHA
LHC
・ Refer to the specification page for each model's calculation method
LHS

of expansion force and allowable workpiece weight for locating. LHW


LT/LG
TLA-2
Cut Mark TLB-2
(Expanding Direction) TLA-1
3 Mounting Phase of VFL/VFM-C (Cut:For One Direction Locating) ar
Y cul Link Clamp
di
・ The reference position (origin) is determined by VFL/VFM-D (Datum: for reference locating). LK A

n
pe
X LK C

Per
・ VFL/VFM-C (Cut: for one direction locating) locates in one direction (Y-axis), LK W
LM/LJ
so phasing is necessary. When mounting, ensure the VFL/VFM-C (cut) cut mark T MA - 2
T MA - 1
is perpendicular to VFL/VFM-D (datum).
VFL/VFM-D (Datum) VFL/VFM-C (Cut) Work Support
(There is a cut mark (▲) on top of the flange on the VFL/VFM-C unit that For Reference Locating (X-axis / Y-axis) For One Direction (Y-axis) LD

shows the locating direction.) (Equivalent to Round Pin) (Equivalent to Diamond Pin) LC
T NC
TC
Air Sensing
Lift Cylinder

Workpiece Hole Distance ※1 LLW

4 Distance Accuracy between Expansion Locating Pins and between Workpiece Holes Compact Cylinder
LL
Work-
・ The distance accuracy for the expansion locating pin should be better than ±0.02mm. piece LLR
LLU
・ The distance accuracy of workpiece holes (pallet holes) (※1) should be DP
DR
within allowable difference. (Refer to Notes for Design .)
Base Plate DS
DT
Cylinder Distance
better than ±0.02 Block Cylinder
DBA
DBC

Reference Surface of Z-axis Centering Vise

5 Seat Setting Workpiece


FVA
FVD
Clearance

・ Standard model and -M:Release Confirmation model have no seating surface FVC

Control Valve
(reference surface towards Z-axis). Please prepare the seat separately. Z Seat
BZL
BZT
Base Plate BZX/JZG

Expansion Locating Pin Pallet Clamp


VS
VT

Expansion
Work Clamp Expansion locating pin can be used for locating only. Locating Pin

6 Setting Additional Work Clamps VF L


Work Clamp VF M

・ Expansion locating pin has no clamping function. VFJ


VFK
・ Additional clamps should be added to Workpiece
Pull Stud Clamp
clamp a workpiece. FP
FQ
Customized
Spring Cylinder
DW A /DW B

942
Expansion Locating Pin Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL

Model No. Indication

VFL 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7

1 Body Size

2 : Select from Workpiece Hole Diameter φ8 / φ9 / φ10 / φ11


3 : Select from Workpiece Hole Diameter φ12 / φ13 / φ14 / φ15
4 : Select from Workpiece Hole Diameter φ16 / φ17 / φ18 / φ19 / φ20
5 : Select from Workpiece Hole Diameter φ21 / φ22 / φ23 / φ24 / φ25
6 : Select from Workpiece Hole Diameter φ26 / φ27 / φ28 / φ29 / φ30

2 Design No.

0 :Revision Number

Contact us for workpiece hole diameters not listed below.


3 Workpiece Hole Diameter (Workpiece hole machining accuracy should be H8 or better.)

Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
+ 0.022 + 0.022
Workpiece Hole Diam. φWA H8 8 0 9 0 10 + 0.022
0 11 + 00.027 12 + 00.027 13 + 00.027 14 + 00.027 15 + 00.027 16 + 00.027 17 + 00.027 18 + 00.027 19 + 00.033 20 + 00.033
VFL2000 Selection Range
VFL3000 Selection Range
VFL4000 Selection Range

Workpiece Hole DiameterφWA


Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
Workpiece Hole Diam. φWA H8 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0
VFL5000 Selection Range
VFL6000 Selection Range

4 Functions

D :Datum (for Reference Locating) D C


Cut Mark
C :Cut (for One Direction Locating)

Datum Cut

5 Seating Height

Seating Height H (mm)


Seating Height

Model No.
15 20 25 30
VFL2000 Selection Range
VFL3000 Selection Range
VFL4000 Selection Range
VFL5000 Selection Range Note:

VFL6000 Selection Range Prepare the seat separately for 6 Option Blank:Standard
and M:Release Confirmation Model.

943
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Series

Pneumatic Series

Hydraulic Series

Valve / Coupler
Hydraulic Unit

Manual Operation
Accessories

6 Options Cautions / Others

Blank :None (Standard)


Hole Clamp
Note:
B :with Seating Surface SFA
Contact us for combined use of B:with Seating Surface SFC
M :Release Confirmation Model and M:Release Confirmation model.
Swing Clamp
LHA
LHC
LHS

7 Port Position Required only when selecting 6 Option:B (with Seating Surface), M (Release Confirmation Model). LHW
LT/LG
TLA-2
R :Refer to External Dimensions TLB-2
Note: TLA-1
L :Refer to External Dimensions
Refer to  Port Position on each External Dimension page for details. Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VF L
VFM
VFJ
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

944
Expansion Locating Pin Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL

Specifications:VFL2000 / VFL3000 / VFL4000


Model No. VFL2000 VFL3000 VFL4000
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
Workpiece Hole Diam. (Standard Diam.) mm φ8H8 + 0.022
0 φ9H8 + 0.022
0 φ10H8 + 0.022
0 φ11H8 + 00.027 φ12H8 + 00.027 φ13H8 + 00.027 φ14H8 + 00.027 φ15H8 + 00.027 φ16H8 + 00.027 φ17H8 + 00.027 φ18H8 + 00.027 φ19H8 + 00.033 φ20H8 + 0.033
0

Locating Repeatability mm 0.003


Allowable Offset (C:Cut) mm ±0.05 ±0.05 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15
Expanding Force (F) ※1 N 190 200 220 200 180 200 190 180 280 290 290 290 290
Allowable Thrust Load ※2 N 1500 1500 2000 2000 2500 2500 2500 2500 3500 3500 3500 3500 4000
Cylinder Capacity (Empty Action) cm3 0.07 0.08 0.18
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Specifications:VFL5000 / VFL6000
Model No. VFL5000 VFL6000
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300
Workpiece Hole Diam. (Standard Diam.) mm φ21H8 + 0.033
0 φ22H8 + 0.033
0 φ23H8 + 0.033
0 φ24H8 + 0.033
0 φ25H8 + 0.033
0 φ26H8 + 0.033
0 φ27H8 + 0.033
0 φ28H8 + 0.033
0 φ29H8 + 0.033
0 φ30H8 + 0.033
0

Locating Repeatability mm 0.003


Allowable Offset (C:Cut) mm ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15
Expanding Force (F) ※1 N 640 640 640 640 640 1080 1080 1080 1080 1080
Allowable Thrust Load ※2 N 5500 5500 5500 5500 6500 7500 7500 7500 9000 9000
Cylinder Capacity (Empty Action) cm3 0.35 0.47
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Notes:
※1. Expanding force shows the calculated value when coefficient friction is μ0.2.
Refer to the following for the relative equation of expanding force and allowable workpiece weight for locating.
※2. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates with spring and releases with hydraulic pressure. (Hydraulic Pressure Single Action)
2. This cylinder is used only for locating and does not have a clamping function.

Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating

F W F

Horizontal Attitude μ Vertical Attitude


Seat

Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5


Workpiece Weight (W) ≦ Workpiece Weight (W) ≦ Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5
Friction Coefficient of Workpiece Seat Face (μ)

945
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Thrust Load/Displacement Curve Series

Pneumatic Series
This graph shows the relationship between thrust load and displacement.
Thrust load is the static load applied perpendicular to the center axis of the VFL (Hydraulic Expansion Locating Pin).
Hydraulic Series

Note :
Valve / Coupler
This graph shows the thrust load (static load) on a single datum (VFL-D) cylinder
Hydraulic Unit
that is not used with any other cylinders, etc.
Manual Operation
Accessories
Displacement
Cautions / Others
【How to Read the Thrust Load/Displacement Curve】
Workpiece
ex.) When using VFL2000-100
Thrust Load
Requirement : When a 2000N thrust load is Hole Clamp

applied to an expanded VFL2000-100, SFA


Seat SFC
the displacement will be about 0.018mm.
Swing Clamp
LHA
LHC
VFL2000 VFL3000 LHS
LHW
0.020 0.020
VFL3000-120 LT/LG
0.018 VFL2000-100 0.018 VFL3000-130 TLA-2
VFL2000-110 VFL3000-140
0.016 VFL2000-080 0.016 VFL3000-150 TLB-2
Displacement (mm)

Displacement (mm)
0.014 0.014 TLA-1

0.012 0.012 Link Clamp

0.010 0.010 LK A
LK C
0.008 0.008
VFL2000-090 LK W
0.006 0.006
LM/LJ
0.004 0.004 T MA - 2
0.002 0.002 T MA - 1

0 0 Work Support
0 1000 2000 3000 4000 0 1000 2000 3000 4000
LD
Thrust Load (N) Thrust Load (N) LC
T NC
VFL4000 VFL5000 TC
Air Sensing
0.020 0.020 Lift Cylinder
VFL4000-160 VFL5000-210 VFL5000-250
0.018 0.018 LLW
0.016 0.016
Compact Cylinder
Displacement (mm)

Displacement (mm)

0.014 VFL4000-170 0.014 LL


0.012 VFL4000-180 0.012 VFL5000-240 LLR
VFL4000-200
0.010 VFL4000-190 0.010 LLU
VFL5000-230
DP
0.008 0.008
VFL5000-220 DR
0.006 0.006 DS
0.004 0.004 DT
0.002 0.002 Block Cylinder
0 0 DBA
0 1000 2000 3000 4000 0 2000 4000 6000 8000 10000
DBC
Thrust Load (N) Thrust Load (N)
Centering Vise
FVA
VFL6000
FVD
0.020 FVC
VWM3000-160
VFL6000-260
0.018
Control Valve
0.016 BZL
Displacement (mm)

0.014 BZT
0.012 VFL6000-300 BZX/JZG

0.010 VFL6000-290 Pallet Clamp


0.008 VFL6000-280 VS
VT
0.006
VFL6000-270
0.004 Expansion
Locating Pin
0.002
VF L
0 VFM
0 2000 4000 6000 8000 10000
VFJ
Thrust Load (N) VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

946
Expansion Locating Pin Standard Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL2 / VFL3 / VFL4

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL2000 / VFL3000 /
VFL4000.
When Releasing When Locking (At Full Stroke)
※1
Identification Mark

2-Mounting Bolt (Included) 2-Thread for Jack Bolt

Full Stroke
φR
U V

(Expanding Area)
(E)

(E)
Datum Diameter Datum Diameter

J
A
S

(When Releasing) (At Full Stroke)

Q Q

Workpiece Hole Dimensions

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


VFL-C φWAH8 Workpiece Hole Diameter
(Cut:One Direction Locating) ⊥ 0.05 Y
φWAH8
K+0.5 or more

⊥ 0.05 Y

WB or more

6.3S
View A

6.3S
1 or less

1 or less
5 Seating Height:H15

φL
φM
Expanding Area

60°

Y VFL Mounting Surface


Datum Diameter
K
E

φN
G ◎ φ0.01 X
C

※2
H

Notes:
A

Y
B
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6 direction locating).    indicates the locating direction.


6.5

X
9.5

※2. Do not use spring washer or toothed lock washer.


※3
1-O-ring (Included) ※3. Set the O-ring to the mounting hole side (fixture side) before
W mounting the body.
1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
5 Seating Height:H20 / H25 2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
φL
φM
Expanding Area

60°

Datum Diameter
K
E

φN
1

◎ φ0.01 X
C

G
H
A

※2
B

Y
F

φDh6
6.5

X
9.5

※3
1-O-ring (Included)
W

947
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

Q Q 2-ME Thread
Hydraulic Series

★ ★
Valve / Coupler
Hydraulic Unit

Manual Operation
MA

★ ★ Accessories

Cautions / Others
※4
Air Blow Port MC
φMB
Hole Clamp

φDH7 30° ⊥ 0.01 Z Notes: SFA


Z ※4. Install the air blow port choosing one port from four ★ parts. SFC
Must be 1.3

※5 ※5. There might be foam near the flange bottom depending on


S
6.3S

Mounting
6.3

Swing Clamp
Surface roughness of mounting surface, but this is not a malfunction. LHA
※6. Prepare the hydraulic release port on the bottom within
MF or more

LHC
8.5±0.1

the range of φMD. LHS


1. Make sure to check the cautions for cylinder mounting distance LHW
accuracy, workpiece hole distance accuracy and mounting phase LT/LG
before installation. (Refer to P.1011.) TLA-2
※6 TLB-2
Hydraulic Release Port
TLA-1
※6
φMD±0.05
Link Clamp
LK A
LK C
LK W

External Dimensions and Machining Dimensions for Mounting (mm)


LM/LJ
T MA - 2
Model No. VFL2000-□-□-□ VFL3000-□-□-□ VFL4000-□-□-□ T MA - 1

3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD

Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 0.033 LC
0 0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 32 37 42 32 37 42 32 37 42 32 37 42 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 34 39 44 34 39 44 34 39 44 34 39 44 34 39 44
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 Compact Cylinder

C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 LL
0 0 0 LLR
D h6 (Body Side) 15 - 0.011 15 - 0.011 18 - 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DS
DT
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Block Cylinder

J 4.6 5.1 6 DBA


DBC
K 7.5 8 9.5
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7 Centering Vise

M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18 FVA


FVD
N 14.5 9 9 14.5 10 10 14.5 11 11 14.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 22.5 17 17 22.5 18 18 22.5 19 19 22.5 20 20 22.5 21 21
FVC
P 4 4 5
Control Valve
Q 12 14 17.5
BZL
R 33 37 47
BZT
S 19 19 23 BZX/JZG
U M5×0.8×12 M5×0.8×12 M6×1×16
Pallet Clamp
V M6×1 M6×1 M8×1.25 VS
W AS568-013 (90°
) AS568-013 (90°) AS568-015 (90°) VT
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5 Expansion
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5 Locating Pin
VF L
MA 6.5 6.5 7.5
VFM
MB 3 3 4
VFJ
MC 10.5 10.5 13 VFK
MD 12.1 12.1 15.1
Pull Stud Clamp
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FP
MF 10.5 10.5 11
FQ
+ 0.022 + 0.022
WA  8 0  9 0  10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
 11 0  12 0  13 0  14 0  15 0  16 0  17 0  18 0  19 0  20 0
+ 0.027 + 0.033 + 0.033
Customized
WB 4 4.5 5.5 Spring Cylinder
DW A /DW B
Weight g 60 70 80 60 70 80 60 70 80 60 70 80 70 80 90 70 80 100 70 80 100 70 80 100 110 130 150 110 130 150 110 130 150 110 130 160 120 140 160
948
Expansion Locating Pin Standard Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL5 / VFL6

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL5000 / VFL6000.

When Releasing When Locking (At Full Stroke)


※1
Identification Mark

φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt

7.5 (Expanding Area)


U V

Full Stroke
S

(E)

(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)

30°
30°

.Q

Workpiece Hole Dimensions


P.C.D

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


φWAH8 Workpiece Hole Diameter
⊥ 0.05 ZB
φWAH8
VFL-C ⊥ 0.05 ZB
12.5 or more

6.3S
(Cut:One Direction Locating)

7 or more
6.3S
View A
1 or less

1 or less
φL
φM
Expanding Area

60°

ZB VFL Mounting Surface


Datum Diameter
12
7.5
E

φN
◎ φ0.01 ZA
C

1.5

G
H
A

※2
ZB Notes:
B
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6 direction locating).    indicates the locating direction.


AC

ZA
AB

※2. Do not use spring washer or toothed lock washer.


※3
1-O-ring (Included) ※3. Set the O-ring to the mounting hole side (fixture side) before
W mounting the body.
1. When mounting the product, use three mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.

949
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

.Q
Hydraulic Series

P.C.D
※4
Air Blow Port 3-ME Thread
Valve / Coupler
φ4
Hydraulic Unit

Manual Operation
Accessories

Cautions / Others
★ ★

30°
30°

Hole Clamp
SFA
※4 SFC
Air Blow Port
φ4 Swing Clamp
LHA
LHC

30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3

※5
※4. Install the air blow port choosing one port from two ★ parts. LT/LG
S
6.3S

Mounting
6.3

※5. There might be foam near the flange bottom depending on TLA-2
Surface
roughness of mounting surface, but this is not a malfunction. TLB-2
MF or more
MG±0.1

※6. Prepare the hydraulic release port on the bottom within TLA-1
the range of φMD.
Link Clamp
1. Make sure to check the cautions for cylinder mounting distance
LK A
accuracy, workpiece hole distance accuracy and mounting phase LK C
before installation. (Refer to P.1011.) LK W
φMD ±0.05※6 Hydraulic Release Port
※6
LM/LJ
T MA - 2
T MA - 1

Work Support

External Dimensions and Machining Dimensions for Mounting (mm)


LD
LC
Model No. VFL5000-□-□ VFL6000-□-□ T NC
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 TC

5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 38 43 48 38 43 48 38 43 48 38 43 48 38 43 48 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 LLU

B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC

N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp

U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-119 (90°) Expansion
Locating Pin
AB 11 12.5 VF L
AC 8 8.3 VFM
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFJ
VFK
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5
MD 21.1 24.6 Pull Stud Clamp
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more FP
MF 12.5 14 FQ
Customized
MG 10 11.5
Spring Cylinder
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 DW A /DW B
Weight g 190 220 250 190 220 260 190 230 260 200 230 260 200 230 270 350 400 440 350 400 450 350 400 450 360 410 460 360 410 460
950
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL2-B / VFL3-B / VFL4-B

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL2000-BR / VFL3000-BR / VFL4000-BR.
The ports of VFL2000-BL / VFL3000-BL / VFL4000-BL are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark

2-Mounting Bolt (Included) BA 2-Thread for Jack Bolt

Full Stroke
φR
U V

(Expanding Area)
(K)

(K)
S

Datum Diameter Datum Diameter

J
A (When Releasing) (At Full Stroke)

45°
45°

BL

FC
O
W

.Q
P.C.D
BB

Seating Confirmation Air Hole


φ1.5
Workpiece Hole Dimensions

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


VFL-C φWAH8 Workpiece Hole Diameter
⊥ 0.05 Y
(Cut:One Direction Locating) φWAH8
K+0.5 or more

⊥ 0.05 Y

WB or more

6.3S
View A

6.3S
1 or less

1 or less
5 Seating Height:H15

φL
φM
60°
Expanding Area

Y VFL Mounting Surface


Datum Diameter
K

G φN
C

◎ φ0.01 X
1
H±0.005

Notes:
A

Y
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6 direction locating).    indicates the locating direction.


6.5

X 1-O-ring (Included)
9.5

※2. Set the O-ring to the mounting hole side (fixture side) before
BC
※2 mounting the body.
1-O-ring (Included)
1. When mounting the product, use two mounting bolts
W
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
5 Seating Height:H20 / H25 (BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
φL
seating confirmation air port.
φM
60°
Expanding Area

Datum Diameter Port Position


K

φN
R L
C

◎ φ0.01 X
1

Seating Confirmation Air Hole


G
H±0.005
A

Y
F

φDh6
6.5

X 1-O-ring (Included)
9.5

Seating Confirmation Air Port


BC
※2
1-O-ring (Included) Air Blow Port
W
Note:
3. Please make sure that the port positions are correct.
951
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

2-ME Thread 2-ME Thread Hydraulic Series

P.C.D .Q Valve / Coupler


.Q P.C.D Hydraulic Unit

Manual Operation
Accessories

45°

45°
45°

45°
Cautions / Others

Hole Clamp
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFA
φMB φMA φMA φMB SFC

φDH7 Swing Clamp


30° ⊥ 0.01 Z
Z LHA
Must be 1.3

※3 Notes: LHC
S

Mounting
6.3S

6.3

Surface ※3. There might be foam near the flange bottom depending on LHS
LHW
roughness of mounting surface, but this is not a malfunction.
MF or more
8.5±0.1

LT/LG
※4. Prepare the hydraulic release port on the bottom within
TLA-2
the range of φMD.
TLB-2
1. Make sure to check the cautions for cylinder mounting distance
TLA-1
accuracy, workpiece hole distance accuracy and mounting phase
※4 before installation. (Refer to P.1011.) Link Clamp
Hydraulic Release Port
LK A
※4
φMD±0.05 LK C
LK W

External Dimensions and Machining Dimensions for Mounting (mm)


LM/LJ
T MA - 2
Model No. VFL2000-□-□-□-B□ VFL3000-□-□-□-B□ VFL4000-□-□-□-B□ T MA - 1

3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD

Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 0.033 LC
0 0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 32 37 42 32 37 42 32 37 42 32 37 42 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 34 39 44 34 39 44 34 39 44 34 39 44 34 39 44
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Compact Cylinder

D h6 (Body Side)
0
15 - 0.011 15 - 00.011 0
18 - 0.011 LL
+ 0.018 + 0.018 + 0.018 LLR
D H7 (Machining Hole) 15 0 15 0 18 0
LLU
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DP
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DR
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 DS
DT
J 4.6 5.1 6
K 7.5 8 9.5 Block Cylinder

L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7 DBA
DBC
M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18
N 15.5 16.5 17.5 18.5 19.5 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 Centering Vise

P 4 4 5 FVA
FVD
Q 24 28 35
FVC
R 33 37 47
Control Valve
S 9.5 9.5 11.5
BZL
U M5×0.8×12 M5×0.8×12 M6×1×16
BZT
V M6×1 M6×1 M8×1.25 BZX/JZG
W AS568-013 (90°) AS568-013 (90°
) AS568-015 (90°)
Pallet Clamp
BA 12 13 14 14 15 16 17 18 19 20 21 22 23 VS
BB 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 VT
BC AS568-006 (90°) AS568-006 (90°
) AS568-007 (90°) Expansion
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5 Locating Pin
VF L
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5
VFM
MA 3 3 4
VFJ
MB 3 3 4 VFK
MD 12.1 12.1 15.1
Pull Stud Clamp
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FP
MF 10.5 10.5 11
FQ
+ 0.022 + 0.022
WA  8 0  9 0  10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
 11 0  12 0  13 0  14 0  15 0  16 0  17 0  18 0  19 0  20 0
+ 0.027 + 0.033 + 0.033
Customized
WB 4 4.5 5.5 Spring Cylinder
DW A /DW B
Weight g 70 80 100 70 80 100 70 80 100 70 80 100 80 100 110 80 100 110 80 100 120 80 100 120 130 160 180 130 160 190 130 160 190 140 160 190 140 160 190
952
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL5-B / VFL6-B

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL5000-BR / VFL6000-BR.
The ports of VFL5000-BL / VFL6000-BL are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark

3-Mounting Bolt (Included) BA 3-Thread for Jack Bolt


φ

7.5 (Expanding Area)


U R V

Full Stroke
S
Datum Diameter Datum Diameter

12

12
A (When Releasing) (At Full Stroke)
30°

BD
BL
OW

°
60
BB

FC
.Q

Seating Confirmation Air Hole Workpiece Hole Dimensions


P.C.D

φ1.5

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


φWAH8 Workpiece Hole Diameter
⊥ 0.05 ZB
φWAH8
VFL-C ⊥ 0.05 ZB
12.5 or more

6.3S
(Cut:One Direction Locating)

7 or more
6.3S
View A
1 or less

1 or less
φL
φM

60°
Expanding Area

ZB VFL Mounting Surface


Datum Diameter
12

7.5

φN
C

1.5

G ◎ φ0.01 ZA
H±0.005
A

ZB Notes:
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6 direction locating).    indicates the locating direction.


AC

ZA
AB

1-O-ring (Included)
※2. Set the O-ring to the mounting hole side (fixture side) before
BC
※2 mounting the body.
1-O-ring (Included)
W 1. When mounting the product, use three mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
seating confirmation air port.

Port Position
R L

Seating Confirmation Air Port

Air Blow Port

Note:
3. Please make sure that the port positions are correct.
953
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

.Q

P.C.D
Hydraulic Series

P.C.D

.Q
Air Blow Port 3-ME Thread 3-ME Thread Air Blow Port
Valve / Coupler
φ4 φ4
Hydraulic Unit

Manual Operation
Accessories

Cautions / Others
30°

30°
°

60
60

°
Hole Clamp
SFA
SFC

Seating Confirmation Air Port Seating Confirmation Air Port Swing Clamp

φ4 φ4 LHA
LHC

30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3

※3 ※3. There might be foam near the flange bottom depending on LT/LG
S

Mounting
6.3S

6.3

Surface roughness of mounting surface, but this is not a malfunction. TLA-2


※4. Prepare the hydraulic release port on the bottom within TLB-2
MF or more
MG±0.1

the range of φMD. TLA-1


1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.) LK C
LK W
φMD ±0.05※4 Hydraulic Release Port
※4
LM/LJ
T MA - 2

External Dimensions and Machining Dimensions for Mounting (mm)


T MA - 1

Work Support
Model No. VFL5000-□-□-B□ VFL6000-□-□-B□
LD
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 LC
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 T NC
Workpiece Hole Diameter (Standard Diam.) φ21H8 + 0.033
0 φ22H8 + 0.033
0 φ23H8 + 0.033
0 φ24H8 + 0.033
0 φ25H8 + 0.033
0 φ26H8 + 0.033
0 φ27H8 + 0.033
0 φ28H8 + 0.033
0 φ29H8 + 0.033
0 φ30H8 + 0.033
0 TC

At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less Air Sensing
Datum Diameter Lift Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more LLW
Full Stroke 1
Compact Cylinder
A 38 43 48 38 43 48 38 43 48 38 43 48 38 43 48 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5
LL
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LLR
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 LLU

D H7 (Machining Hole) 24 + 0.021


29 + 0.021 DP
0 0
DR
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14
DS
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DT
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
Block Cylinder
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 DBA
M 19 20 21 22 23 24 25 26 27 28 DBC
N 28.5 29.5 30.5 31.5 32.5 33.5 34.5 35.5 36.5 37.5
Centering Vise
P 5 6
FVA
Q 40 48 FVD
R 51 62 FVC

S 14 16.5 Control Valve


U M6×1×16 M8×1.25×20 BZL
V M8×1.25 M10×1.5 BZT
BZX/JZG
W AS568-019 (90°) AS568-119 (90°)
AB 11 12.5 Pallet Clamp

AC 8 8.3 VS
VT
BA 24 25 26 27 28 29 30 31 32 33
BB 12.5 13 13.5 14 14.5 15 15.5 16 16.5 17 Expansion
Locating Pin
BC AS568-007 (90°) 1BP5 VF L
BD 12.5 13 13.5 14 14.3 15 15.5 16 16.5 16.5 VFM
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFJ
VFK
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5
MD 21.1 24.6 Pull Stud Clamp
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more FP
MF 12.5 14 FQ
Customized
MG 10 11.5
Spring Cylinder
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 DW A /DW B
Weight g 190 220 250 190 220 260 190 230 260 200 230 260 200 230 270 350 400 440 350 400 450 350 400 450 360 410 460 360 410 460
954
Expansion Locating Pin Release Confirmation Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL2-M / VFL3-M / VFL4-M

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL2000-MR / VFL3000-MR / VFL4000-MR.
The ports of VFL2000-ML / VFL3000-ML / VFL4000-ML are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark
2-Mounting Bolt (Included) 2-Thread for Jack Bolt

Full Stroke
φR
U V

T
EX

(Expanding Area)
S

(E)

(E)
Datum Diameter Datum Diameter

J
A (When Releasing) (At Full Stroke)

45°
45°

R
BL

O
NS
O
W

SE
.Q
P.C.D

Workpiece Hole Dimensions

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


VFL-C φWAH8 Workpiece Hole Diameter
⊥ 0.05 Y
(Cut:One Direction Locating) φWAH8
K+0.5 or more

⊥ 0.05 Y

WB or more

6.3S
View A

6.3S
1 or less

1 or less
5 Seating Height:H15

φL
φM
Expanding Area

60°

Y VFL Mounting Surface


Datum Diameter
K
E

G φN
C

◎ φ0.01 X
1

Notes:
A

Y
B
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6 direction locating).    indicates the locating direction.


6.5

X
9.5

※2. Set the O-ring to the mounting hole side (fixture side) before
※2
1-O-ring (Included) mounting the body.
W 1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
5 Seating Height:H20 / H25 (EXT:Air Vent Port, BLOW:Air Blow Port, SENSOR:Release
Confirmation Air Port) Continuously supply air pressure to
φL
the air blow port and release confirmation air port.
φM
3. This product has no seat. Choose option -B:with Seating
Expanding Area

60° Surface or prepare another seat if necessary.

Datum Diameter
Port Position
K
E

φN
R L
1
C

◎ φ0.01 X Air Vent Port


G
H
A
B

Y
F

φDh6
6.5

X
9.5

Release Confirmation Air Port


※2
1-O-ring (Included)
W Air Blow Port

Note:
4. Please make sure that the port positions are correct.
955
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Air Vent Port 2-ME Thread 2-ME Thread Air Vent Port
Hydraulic Series
φMC φMC

Valve / Coupler
P.C.D .Q
.Q P.C.D
Hydraulic Unit

T
T
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port
SFC
φMB φMA φMA φMB
φDH7 Swing Clamp
30° ⊥ 0.01 Z
Z LHA
Must be 1.3

※3 Notes: LHC
S
6.3S

Mounting
6.3

Surface LHS
※3. There might be foam near the flange bottom depending on
LHW
roughness of mounting surface, but this is not a malfunction.
MF or more
8.5±0.1

LT/LG
※4. Prepare the hydraulic release port on the bottom within
TLA-2
the range of φMD. TLB-2
1. Make sure to check the cautions for cylinder mounting distance TLA-1
accuracy, workpiece hole distance accuracy and mounting phase
※4 Link Clamp
Hydraulic Release Port before installation. (Refer to P.1011.)
※4
LK A
φMD±0.05 LK C
LK W
External Dimensions and Machining Dimensions for Mounting (mm) LM/LJ
T MA - 2
Model No. VFL2000-□-□-□-M□ VFL3000-□-□-□-M□ VFL4000-□-□-□-M□
T MA - 1
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25
LD
Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022
0 φ9H8 + 0.022
0 φ10 + 0.022
H8 0 φ11 + 0.027
H8 0 φ12 + 0.027
H8 0 φ13 + 0.027
H8 0 φ14 + 0.027
H8 0 φ15 + 0.027
H8 0 φ16 + 0.027
H8 0 φ17 + 0.027
H8 0 φ18 + 0.027
H8 0 φ19 + 0.033
H8 0 φ20 + 0.033
H8 0
LC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less T NC
Datum Diameter
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more TC
Air Sensing
Full Stroke 0.65 0.75 1.0
Lift Cylinder
A 32 37 42 32 37 42 32 37 42 32 37 42 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 32.5 37.5 42.5 34 39 44 34 39 44 34 39 44 34 39 44 34 39 44 LLW
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5
Compact Cylinder
C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4
LL
0
D h6 (Body Side) 15 - 0.011 15 - 00.011 0
18 - 0.011 LLR
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0 LLU
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10
DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11
DS
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DT
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25
Block Cylinder
J 4.6 5.1 6 DBA
K 7.5 8 9.5 DBC
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7
Centering Vise
M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18
FVA
N 14.5 9 9 14.5 10 10 14.5 11 11 14.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 22.5 17 17 22.5 18 18 22.5 19 19 22.5 20 20 22.5 21 21 FVD
P 4 4 5 FVC

Q 24 28 35 Control Valve
R 33 37 47 BZL
S 9.5 9.5 11.5 BZT
BZX/JZG
T 35° 30° 30°
U M5×0.8×12 M5×0.8×12 M6×1×16 Pallet Clamp

V M6×1 M6×1 M8×1.25 VS


VT
W AS568-013 (90°
) AS568-013 (90°
) AS568-015 (90°)
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5 Expansion
Locating Pin
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5 VF L
MA 3 3 4 VFM
MB 3 3 4 VFJ
VFK
MC 3 3 4
MD 12.1 12.1 15.1 Pull Stud Clamp
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more FP

MF 10.5 10.5 11 FQ
+ 0.022 + 0.022 Customized
WA  8 0  9 0  10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
 11 0  12 0  13 0  14 0  15 0  16 0  17 0  18 0  19 0  20 0
+ 0.027 + 0.033 + 0.033
Spring Cylinder
WB 4 4.5 5.5 DW A /DW B
Weight g 70 80 100 70 80 100 70 80 100 70 80 100 80 100 110 80 100 110 80 100 120 80 100 120 130 160 180 130 160 190 130 160 190 140 160 190 140 160 190
956
Expansion Locating Pin Release Confirmation Locating Repeatability:3μm Spring Lock/Hyd. Release model VFL5-M / VFL6-M

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL5000-MR / VFL6000-MR.
The ports of VFL5000-ML / VFL6000-ML are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark

φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt

7.5 (Expanding Area)


U V

Full Stroke
S

(E)

(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)
30°

BL

°
OW

60
OR
30

EX
T NS
SE
°

.Q

Workpiece Hole Dimensions


P.C.D

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


φWAH8 Workpiece Hole Diameter
⊥ 0.05 ZB
φWAH8
VFL-C ⊥ 0.05 ZB
12.5 or more

6.3S
(Cut:One Direction Locating)

7 or more
6.3S
View A
1 or less

1 or less
φL
φM
Expanding Area

60°

ZB VFL Mounting Surface


Datum Diameter
12
7.5
E

φN
◎ φ0.01 ZA
C

1.5

G
H
A

ZB Notes:
B
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6 direction locating).    indicates the locating direction.


AC

ZA
AB

※2. Set the O-ring to the mounting hole side (fixture side) before
※2
1-O-ring (Included) mounting the body.
W 1. When mounting the product, use three mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(EXT:Air Vent Port, BLOW:Air Blow Port, SENSOR:Release
Confirmation Air Port) Continuously supply air pressure to
the air blow port and release confirmation air port.
3. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.

Port Position
R L

Release Confirmation Air Port

Air Vent Port

Air Blow Port


Note:
4. Please make sure that the port positions are correct.
957
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

.Q

P.C.D
Hydraulic Series

P.C.D

.Q
Air Blow Port 3-ME Thread 3-ME Thread Air Blow Port
Valve / Coupler
φ4 φ4
Hydraulic Unit

Manual Operation
Accessories

Cautions / Others
30°

30°
°

60
60
Hole Clamp

°
30

SFA

30
°

SFC

Air Vent Port Release Confirmation Air Port Release Confirmation Air Port Air Vent Port Swing Clamp

φ4 φ4 φ4 φ4 LHA
LHC

30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3

※3 ※3. There might be foam near the flange bottom depending on LT/LG
S

Mounting
6.3S

6.3

Surface roughness of mounting surface, but this is not a malfunction. TLA-2


※4. Prepare the hydraulic release port on the bottom within TLB-2
MF or more
MG±0.1

the range of φMD. TLA-1

1. Make sure to check the cautions for cylinder mounting distance Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase LK A
before installation. (Refer to P.1011.) LK C
LK W
φMD ±0.05※4 Hydraulic Release Port
※4
LM/LJ
T MA - 2
T MA - 1

Work Support

External Dimensions and Machining Dimensions for Mounting (mm)


LD
LC
Model No. VFL5000-□-□-M□ VFL6000-□-□-M□ T NC
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 TC

H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
5 Seating Height
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 38 43 48 38 43 48 38 43 48 38 43 48 38 43 48 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 44.5 49.5 54.5 LLU

B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC

N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp

U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-119 (90°) Expansion
Locating Pin
AB 11 12.5 VF L
AC 8 8.3 VFM
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFJ
VFK
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5
MD 21.1 24.6 Pull Stud Clamp
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more FP
MF 12.5 14 FQ
Customized
MG 10 11.5
Spring Cylinder
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 DW A /DW B
Weight g 190 220 250 190 220 260 190 230 260 200 230 260 200 230 270 350 400 440 350 400 450 350 400 450 360 410 460 360 410 460
958
Expansion Locating Pin Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM

Model No. Indication

VFM 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7

1 Body Size

2 : Select from Workpiece Hole Diameter φ8 / φ9 / φ10 / φ11


3 : Select from Workpiece Hole Diameter φ12 / φ13 / φ14 / φ15
4 : Select from Workpiece Hole Diameter φ16 / φ17 / φ18 / φ19 / φ20
5 : Select from Workpiece Hole Diameter φ21 / φ22 / φ23 / φ24 / φ25
6 : Select from Workpiece Hole Diameter φ26 / φ27 / φ28 / φ29 / φ30

2 Design No.

0 :Revision Number

Contact us for workpiece hole diameters not listed below.


3 Workpiece Hole Diameter (Workpiece hole machining accuracy should be H8 or better.)

Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
+ 0.022 + 0.022
Workpiece Hole Diam. φWA H8 8 0 9 0 10 + 0.022
0 11 + 00.027 12 + 00.027 13 + 00.027 14 + 00.027 15 + 00.027 16 + 00.027 17 + 00.027 18 + 00.027 19 + 00.033 20 + 00.033
VFM2000 Selection Range
VFM3000 Selection Range
VFM4000 Selection Range

Workpiece Hole DiameterφWA


Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
Workpiece Hole Diam. φWA H8 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0
VFM5000 Selection Range
VFM6000 Selection Range

4 Functions

D :Datum (for Reference Locating) D C


Cut Mark
C :Cut (for One Direction Locating)

Datum Cut

5 Seating Height

Seating Height H (mm)


Seating Height

Model No.
15 20 25 30
VFM2000 Selection Range
VFM3000 Selection Range
VFM4000 Selection Range
VFM5000 Selection Range Note:

VFM6000 Selection Range Prepare the seat separately for 6 Option Blank:Standard
and M:Release Confirmation Model.

959
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Series

Pneumatic Series

Hydraulic Series

Valve / Coupler
Hydraulic Unit

Manual Operation
Accessories

6 Options Cautions / Others

Blank :None (Standard)


Hole Clamp
Note:
B :with Seating Surface SFA
Contact us for combined use of B:with Seating Surface SFC
M :Release Confirmation Model and M:Release Confirmation model.
Swing Clamp
LHA
LHC
LHS

7 Port Position Not required only when selecting 6 Option:Blank (Standard) of VFM2000 / VFM3000 / VFM4000. LHW
LT/LG
TLA-2
R :Refer to External Dimensions TLB-2
Note: TLA-1
L :Refer to External Dimensions
Refer to  Port Position on each External Dimension page for details. Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VFL
VF M
VFJ
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

960
Expansion Locating Pin Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM

Specifications:VFM2000 / VFM3000 / VFM4000


Model No. VFM2000 VFM3000 VFM4000
3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200
Workpiece Hole Diam. (Standard Diam.) mm φ8H8 + 0.022
0 φ9H8 + 0.022
0 φ10H8 + 0.022
0 φ11H8 + 00.027 φ12H8 + 00.027 φ13H8 + 00.027 φ14H8 + 00.027 φ15H8 + 00.027 φ16H8 + 00.027 φ17H8 + 00.027 φ18H8 + 00.027 φ19H8 + 00.033 φ20H8 + 0.033
0

Locating Repeatability mm 0.003


Allowable Offset (C:Cut) mm ±0.05 ±0.05 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.10 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15
at 2.5MPa 260 260 280 260 260 290 270 260 390 400 400 400 400
Expanding Force (F) ※1
at 5.0MPa 680 680 700 680 680 710 690 680 980 990 990 990 1000
N
at 7.0MPa 1010 1020 1040 1020 1020 1040 1030 1020 1450 1460 1460 1460 1470
Allowable Thrust Load ※2 N 1500 1500 2000 2000 2500 2500 2500 2500 3500 3500 3500 3500 4000
Cylinder Capacity Release side 0.07 0.08 0.18
(Empty Action) cm3 Lock side 0.06 0.06 0.12
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Specifications:VFM5000 / VFM6000
Model No. VFM5000 VFM6000
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300
Workpiece Hole Diam. (Standard Diam.) mm φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +00.033 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0

Locating Repeatability mm 0.003


Allowable Offset (C:Cut) mm ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15 ±0.15
at 2.5MPa 750 750 750 750 750 1210 1220 1220 1220 1220
Expanding Force (F) ※1
at 5.0MPa 1690 1690 1690 1690 1690 2620 2630 2630 2630 2630
N
at 7.0MPa 2440 2440 2440 2440 2440 3740 3750 3750 3750 3750
Allowable Thrust Load ※2 N 5500 5500 5500 5500 6500 7500 7500 7500 9000 9000
Cylinder Capacity Release side 0.27 0.4
(Empty Action) cm3 Lock side 0.19 0.28
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Notes:
※1. Expanding force shows the calculated value when coefficient friction is μ0.2.
Refer to the following for the relative equation of expanding force and allowable workpiece weight for locating.
※2. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates and releases with hydraulic pressure. (Hydraulic Pressure Double Action)
2. This cylinder is used only for locating and does not have a clamping function.

Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating

F W F

Horizontal Attitude μ Vertical Attitude


Seat

Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5


Workpiece Weight (W) ≦ Workpiece Weight (W) ≦ Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5
Friction Coefficient of Workpiece Seat Face (μ)

961
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Thrust Load/Displacement Curve Series

Pneumatic Series
This graph shows the relationship between thrust load and displacement.
Thrust load is the static load applied perpendicular to the center axis of the VFM (Hydraulic Expansion Locating Pin).
Hydraulic Series

Note :
Valve / Coupler
This graph shows the thrust load (static load) on a single datum (VFM-D) cylinder
Hydraulic Unit
that is not used with any other cylinders, etc.
Manual Operation
Accessories
Displacement
Cautions / Others
【How to Read the Thrust Load/Displacement Curve】
Workpiece
ex.) When using VFM2000-100
Thrust Load
Requirement : When a 2000N thrust load is Hole Clamp

applied to an expanded VFM2000-100, SFA


Seat SFC
the displacement will be about 0.018mm.
Swing Clamp
LHA
LHC
VFM2000 VFM3000 LHS
LHW
0.020 0.020
VFM3000-120 LT/LG
0.018 VFM2000-100 0.018 VFM3000-130 TLA-2
VFM2000-110 VFM3000-140
0.016 VFM2000-080 0.016 VFM3000-150 TLB-2
Displacement (mm)

Displacement (mm)
0.014 0.014 TLA-1

0.012 0.012 Link Clamp

0.010 0.010 LK A
LK C
0.008 0.008
VFM2000-090 LK W
0.006 0.006
LM/LJ
0.004 0.004 T MA - 2
0.002 0.002 T MA - 1

0 0 Work Support
0 1000 2000 3000 4000 0 1000 2000 3000 4000
LD
Thrust Load (N) Thrust Load (N) LC
T NC
VFM4000 VFM5000 TC
Air Sensing
0.020 0.020 Lift Cylinder
VFM4000-160 VFM5000-210 VFM5000-250
0.018 0.018 LLW
0.016 0.016
Compact Cylinder
Displacement (mm)

Displacement (mm)

0.014 VFM4000-170 0.014 LL


0.012 VFM4000-180 0.012 VFM5000-240 LLR
VFM4000-200
0.010 VFM4000-190 0.010 LLU
VFM5000-230
DP
0.008 0.008
VFM5000-220 DR
0.006 0.006 DS
0.004 0.004 DT
0.002 0.002 Block Cylinder
0 0 DBA
0 1000 2000 3000 4000 0 2000 4000 6000 8000 10000
DBC
Thrust Load (N) Thrust Load (N)
Centering Vise
FVA
VFM6000
FVD
0.020 FVC
VWM3000-160
VFM6000-260
0.018
Control Valve
0.016 BZL
Displacement (mm)

0.014 BZT
0.012 VFM6000-300 BZX/JZG

0.010 VFM6000-290 Pallet Clamp


0.008 VFM6000-280 VS
VT
0.006
VFM6000-270
0.004 Expansion
Locating Pin
0.002
VFL
0 VF M
0 2000 4000 6000 8000 10000
VFJ
Thrust Load (N) VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

962
Expansion Locating Pin Standard Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM2 / VFM3 / VFM4

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFM2000 / VFM3000 / VFM4000.

When Releasing When Locking (At Full Stroke)


※1
Identification Mark

2-Mounting Bolt (Included) 2-Thread for Jack Bolt

Full Stroke
φR
U V

(Expanding Area)
(E)

(E)
Datum Diameter Datum Diameter

J
A
S

(When Releasing) (At Full Stroke)

Q Q

Workpiece Hole Dimensions

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


VFM-C φWAH8 Workpiece Hole Diameter
(Cut:One Direction Locating) ⊥ 0.05 Y
φWAH8
K+0.5 or more

⊥ 0.05 Y

WB or more

6.3S
View A

6.3S
1 or less

1 or less
5 Seating Height:H15

φL
φM
Expanding Area

60°

Y VFM Mounting Surface


Datum Diameter
K
E

φN
G ◎ φ0.01 X
C

※2
H

Y Notes:
B
F

※1. Identification mark is only marked on -C:Cut (for one


A

φDh6 direction locating).    indicates the locating direction.


5

X
※2. Do not use spring washer or toothed lock washer.
1-O-ring (Included)
18

※3. Set the O-ring to the mounting hole side (fixture side) before
W
mounting the body.
1-O-ring (Included)
※3 1. When mounting the product, use two mounting bolts
W (Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
5 Seating Height:H20 / H25 2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
φL
φM
Expanding Area

60°

Datum Diameter
K
E

φN
1

◎ φ0.01 X
C

G
H

※2
B

Y
A

φDh6
5

X
1-O-ring (Included)
18

※3
1-O-ring (Included)
W
963
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

Q Q 2-ME Thread
Hydraulic Series

★ ★
Valve / Coupler
Hydraulic Unit

Manual Operation
MA

★ ★ Accessories

Cautions / Others
※4
Air Blow Port MC
φMB
Hole Clamp

φDH7 30° ⊥ 0.01 Z Notes: SFA


Z ※4. Install the air blow port choosing one port from four ★ parts. SFC
Must be 1.3

※5. There might be foam near the flange bottom depending on


S
6.3S

Mounting※5
6.3

Swing Clamp
Surface roughness of mounting surface, but this is not a malfunction. LHA
※6. Prepare the hydraulic lock port within   . LHC
7.5

※7. Prepare the hydraulic release port on the bottom within


MF or more

LHS
17±0.1

the range of φMD. LHW


※6

1. Make sure to check the cautions for cylinder mounting distance LT/LG
7

accuracy, workpiece hole distance accuracy and mounting phase TLA-2

before installation. (Refer to P.1011.) TLB-2


TLA-1

Hydraulic Lock Port ※6 Hydraulic Release Port ※7 Link Clamp


※7 LK A
φMD±0.05
LK C
LK W

External Dimensions and Machining Dimensions for Mounting (mm)


LM/LJ
T MA - 2
Model No. VFM2000-□-□-□ VFM3000-□-□-□ VFM4000-□-□-□ T MA - 1

3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD

Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 0.033 LC
0 0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41 46 51 41 46 51 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 Compact Cylinder

C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 LL
0 0 0 LLR
D h6 (Body Side) 15 - 0.011 15 - 0.011 18 - 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DS
DT
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Block Cylinder

J 4.6 5.1 6 DBA


DBC
K 7.5 8 9.5
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7 Centering Vise

M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18 FVA


FVD
N 14.5 9 9 14.5 10 10 14.5 11 11 14.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 22.5 17 17 22.5 18 18 22.5 19 19 22.5 20 20 22.5 21 21
FVC
P 4 4 5
Control Valve
Q 12 14 17.5
BZL
R 33 37 47
BZT
S 19 19 23 BZX/JZG
U M5×0.8×12 M5×0.8×12 M6×1×16
Pallet Clamp
V M6×1 M6×1 M8×1.25 VS
W AS568-013 (90°
) AS568-013 (90°) AS568-015 (90°) VT
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5 Expansion
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5 Locating Pin
VFL
MA 6.5 6.5 7.5
VF M
MB 3 3 4
VFJ
MC 10.5 10.5 13 VFK
MD 12.1 12.1 15.1
Pull Stud Clamp
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FP
MF 19 19 19.5
FQ
+ 0.022 + 0.022
WA  8 0  9 0  10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
 11 0  12 0  13 0  14 0  15 0  16 0  17 0  18 0  19 0  20 0
+ 0.027 + 0.033 + 0.033
Customized
WB 4 4.5 5.5 Spring Cylinder
DW A /DW B
Weight g 70 80 90 70 80 90 70 80 100 70 80 100 80 90 110 80 90 110 80 100 110 80 100 110 130 150 170 130 150 170 130 150 170 130 150 170 130 150 170
964
Expansion Locating Pin Standard Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM5 / VFM6

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFM5000-R / VFM6000-R.
The ports of VFM5000-L / VFM6000-L are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark

φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt

7.5 (Expanding Area)


U V

Full Stroke
S

(E)

(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)

30°
30°

BL

CK
OW

LO
.Q

Workpiece Hole Dimensions


P.C.D

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


φWAH8 Workpiece Hole Diameter
⊥ 0.05 ZB
φWAH8
VFM-C ⊥ 0.05 ZB
12.5 or more

6.3S
(Cut:One Direction Locating)

7 or more
6.3S
View A
1 or less

1 or less
φL
φM
Expanding Area

60°

ZB VFM Mounting Surface


Datum Diameter
12
7.5
E

φN
C

◎ φ0.01 ZA
1.5

G
A

ZB Notes:
B
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6
direction locating).    indicates the locating direction.
5

ZA
8

1-O-ring (Included)
1. When mounting the product, use three mounting bolts
BC
(Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
W Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.

Port Position
R L

Hydraulic Lock Port

Air Blow Port

Note:
4. Please make sure that the port positions are correct.
965
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

.Q

P.C.D
Hydraulic Series

P.C.D

.Q
3-ME Thread 3-ME Thread
Valve / Coupler
Hydraulic Unit

Manual Operation
Accessories

Cautions / Others

30°

30°
30°

30°
Hole Clamp
SFA
SFC
Air Blow Port Hydraulic Lock Port Hydraulic Lock Port Air Blow Port
φ4 φ4 φ4 φ4 Swing Clamp
LHA
LHC

30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3

※2. There might be foam near the flange bottom depending on LT/LG
S
6.3S

Mounting※2
6.3

Surface
roughness of mounting surface, but this is not a malfunction. TLA-2
8.5 or more

※3. Prepare the hydraulic release port on the bottom within TLB-2
the range of φDH7. TLA-1
1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.) LK C
LK W
※3
Hydraulic Lock Port LM/LJ
T MA - 2
T MA - 1

Work Support

External Dimensions and Machining Dimensions for Mounting (mm)


LD
LC
Model No. VFM5000-□-□-□-□ VFM6000-□-□-□-□ T NC
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 TC

5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 40 45 50 40 45 50 40 45 50 40 45 50 40 45 50 LLU

B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC

N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp

U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-022 (90°) Expansion
Locating Pin
BC AS568-007 (90°) 1BP5 VFL
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VF M
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5 VFJ
VFK
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 Pull Stud Clamp
Weight g 180 210 250 180 220 250 190 220 250 190 220 260 190 220 260 320 370 420 330 380 420 330 380 430 340 380 430 340 380 440 FP
FQ
Customized
Spring Cylinder
DW A /DW B

966
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM2-B / VFM3-B / VFM4-B

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFM2000-BR / VFM3000-BR / VFM4000-BR.
The ports of VFM2000-BL / VFM3000-BL / VFM4000-BL are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark
2-Mounting Bolt (Included) BA 2-Thread for Jack Bolt

Full Stroke
φR
U V

(Expanding Area)
(K)

(K)
S

Datum Diameter Datum Diameter

J
A (When Releasing) (At Full Stroke)

45°
45°

BL

FC
O
W

.Q
P.C.D
BB

Seating Confirmation Air Hole


φ1.5
Workpiece Hole Dimensions

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


VFM-C φWAH8 Workpiece Hole Diameter
⊥ 0.05 Y
(Cut:One Direction Locating) φWAH8
K+0.5 or more

⊥ 0.05 Y

WB or more

6.3S
View A

6.3S
1 or less

1 or less
5 Seating Height:H15

φL
φM
60°
Expanding Area

Y VFM Mounting Surface


Datum Diameter
K

G φN
C

◎ φ0.01 X
1
H±0.005

Y Notes:
F

※1. Identification mark is only marked on -C:Cut (for one


A

φDh6 direction locating).    indicates the locating direction.


5

X 1-O-ring (Included)
※2. Set the O-ring to the mounting hole side (fixture side) before
BC
18

mounting the body.


1-O-ring (Included)
1. When mounting the product, use two mounting bolts
W
※2 (Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
Use two jack bolts to remove the product, keeping it
W
parallel to the mounting surface.
2. The port name is marked on the product surface.
5 Seating Height:H20 / H25 (BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
φL
seating confirmation air port.
φM
60°
Expanding Area

Datum Diameter Port Position


K

φN
R L
C

◎ φ0.01 X
1

Seating Confirmation Air Hole


G
H±0.005

Y
A

φDh6
5

X 1-O-ring (Included)
Seating Confirmation Air Port
BC
18

1-O-ring (Included) Air Blow Port


W
※2 Note:
1-O-ring (Included)
4. Please make sure that the port positions are correct.
W
967
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

2-ME Thread 2-ME Thread Hydraulic Series

P.C.D .Q Valve / Coupler


.Q P.C.D Hydraulic Unit

Manual Operation
Accessories

45°
45°

45°
45°

Cautions / Others

Hole Clamp
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFA
φMB φMA φMA φMB SFC

φDH7 Swing Clamp


30° ⊥ 0.01 Z
Z LHA
Must be 1.3

Notes: LHC
S

Mounting※3
6.3S

6.3

Surface LHS
※3. There might be foam near the flange bottom depending on
LHW
roughness of mounting surface, but this is not a malfunction.
7.5

LT/LG
MF or more

※4. Prepare the hydraulic lock port within   .


17±0.1

TLA-2
※5. Prepare the hydraulic release port on the bottom within TLB-2
※4

the range of φMD.


7

TLA-1
1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.)
LK C
Hydraulic Lock Port ※4 Hydraulic Release Port ※5
LK W
±0.05 ※5
φMD LM/LJ
T MA - 2
External Dimensions and Machining Dimensions for Mounting (mm) T MA - 1

Model No. VFM2000-□-□-□-B□ VFM3000-□-□-□-B□ VFM4000-□-□-□-B□ Work Support


3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 LD

5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LC
T NC
Workpiece Hole Diameter (Standard Diam.) φ8 + 0.022
H8 0 φ9 + 0.022
H8 0 φ10 + 0.022
H8 0 φ11 + 0.027
H8 0 φ12 + 0.027
H8 0 φ13 + 0.027
H8 0 φ14 + 0.027
H8 0 φ15 + 0.027
H8 0 φ16 + 0.027
H8 0 φ17 + 0.027
H8 0 φ18 + 0.027
H8 0 φ19 + 0.033
H8 0 φ20 + 0.033
H8 0
TC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less Air Sensing
Datum Diameter
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Lift Cylinder
LLW
Full Stroke 0.65 0.75 1.0
A 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41 46 51 41 46 51 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 Compact Cylinder

C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LL
0 LLR
D h6 (Body Side) 15 - 0.011 15 - 00.011 18
0
- 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DR
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DS
DT
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25
J 4.6 5.1 6 Block Cylinder

K 7.5 8 9.5 DBA


DBC
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7
M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18 Centering Vise

N 15.5 16.5 17.5 18.5 19.5 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 FVA
FVD
P 4 4 5
FVC
Q 24 28 35
Control Valve
R 33 37 47
BZL
S 9.5 9.5 11.5
BZT
U M5×0.8×12 M5×0.8×12 M6×1×16 BZX/JZG
V M6×1 M6×1 M8×1.25
Pallet Clamp
W AS568-013 (90°) AS568-013 (90°) AS568-015 (90°) VS
BA 12 13 14 14 15 16 17 18 19 20 21 22 23 VT
BB 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 Expansion
BC AS568-006 (90°) AS568-006 (90°) AS568-007 (90°) Locating Pin
VFL
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5
VF M
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5
VFJ
MA 3 3 4 VFK
MB 3 3 4
Pull Stud Clamp
MD 12.1 12.1 15.1
FP
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FQ
MF 19 19 19.5 Customized
WA  8
+ 0.022
0  9 + 0.022
0  10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
 11 0  12 0  13 0  14 0  15 0  16 0  17 0  18 0  19 0  20 0
+ 0.027 + 0.033 + 0.033 Spring Cylinder
DW A /DW B
WB 4 4.5 5.5
Weight g 80 90 110 80 90 110 80 90 110 80 100 110 90 110 130 90 110 130 90 110 130 100 110 130 150 170 200 150 180 200 150 180 200 150 180 210 150 180 210 968
Expansion Locating Pin with Seating Surface Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM5-B / VFM6-B

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFM5000-BR / VFM6000-BR.
The ports of VFM5000-BL / VFM6000-BL are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark

3-Mounting Bolt (Included) BA 3-Thread for Jack Bolt


φ

7.5 (Expanding Area)


U R V

Full Stroke
S
Datum Diameter Datum Diameter

12

12
A (When Releasing) (At Full Stroke)

30°
30°

BD
BL

CK
OW

LO
°
BB

FC
30
.Q

Seating Confirmation Air Hole Workpiece Hole Dimensions


P.C.D

φ1.5

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


φWAH8 Workpiece Hole Diameter
⊥ 0.05 ZB
φWAH8
VFM-C ⊥ 0.05 ZB
12.5 or more

6.3S
(Cut:One Direction Locating)

7 or more
6.3S
View A
1 or less

1 or less
φL
φM

60°
Expanding Area

ZB VFM Mounting Surface


Datum Diameter
12

7.5

φN
C

1.5

G ◎ φ0.01 ZA
H±0.005
A

ZB Notes:
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6
direction locating).    indicates the locating direction.
5

ZA
8

2-O-ring (Included)
1. When mounting the product, use three mounting bolts
BC
(Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
W Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(BLOW:Air Blow Port, FC:Seating Confirmation Air Port,
LOCK:Hydraulic Lock Port) Continuously supply air pressure
to the air blow port and seating confirmation air port.

Port Position
R L
Hydraulic Lock Port

Seating Confirmation Air Port

Air Blow Port

Note:
3. Please make sure that the port positions are correct.
969
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

.Q

P.C.D
Hydraulic Series

P.C.D

.Q
3-ME Thread 3-ME Thread
Valve / Coupler
Hydraulic Unit

Manual Operation
Accessories

Cautions / Others
30°

30°

30°
30°
° Hole Clamp

30
SFA
Hydraulic Lock Port Hydraulic Lock Port
30

°
SFC
Air Blow Port φ4 φ4 Air Blow Port
φ4 Seating Confirmation Air Port Seating Confirmation Air Port φ4 Swing Clamp

φ4 φ4 LHA
LHC

30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3

※3. There might be foam near the flange bottom depending on LT/LG
S

Mounting※3
6.3S

6.3

Surface roughness of mounting surface, but this is not a malfunction. TLA-2


8.5 or more

※4. Prepare the hydraulic release port on the bottom within TLB-2
the range of φDH7. TLA-1

1. Make sure to check the cautions for cylinder mounting distance Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase LK A
before installation. (Refer to P.1011.) LK C
※4
Hydraulic Release Port LK W
LM/LJ
T MA - 2

External Dimensions and Machining Dimensions for Mounting (mm)


T MA - 1

Work Support
Model No. VFM5000-□-□-B□ VFM6000-□-□-B□
LD
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 LC
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 T NC
Workpiece Hole Diameter (Standard Diam.) φ21H8 + 0.033
0 φ22H8 + 0.033
0 φ23H8 + 0.033
0 φ24H8 + 0.033
0 φ25H8 + 0.033
0 φ26H8 + 0.033
0 φ27H8 + 0.033
0 φ28H8 + 0.033
0 φ29H8 + 0.033
0 φ30H8 + 0.033
0 TC

At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less Air Sensing
Datum Diameter Lift Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more LLW
Full Stroke 1
Compact Cylinder
A 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 40 45 50 40 45 50 40 45 50 40 45 50 40 45 50
LL
C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 LLR
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 LLU

D H7 (Machining Hole) 24 + 0.021


29 + 0.021 DP
0 0
DR
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14
DS
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° DT
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
Block Cylinder
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 DBA
M 19 20 21 22 23 24 25 26 27 28 DBC
N 28.5 29.5 30.5 31.5 32.5 33.5 34.5 35.5 36.5 37.5
Centering Vise
P 5 6
FVA
Q 40 48 FVD
R 51 62 FVC

S 14 16.5 Control Valve


U M6×1×16 M8×1.25×20 BZL
V M8×1.25 M10×1.5 BZT
BZX/JZG
W AS568-019 (90°) AS568-022 (90°)
BA 24 25 26 27 28 29 30 31 32 33 Pallet Clamp

BB 12.5 13 13.5 14 14.5 15 15.5 16 16.5 17 VS


VT
BC AS568-007 (90°
) 1BP5
BD 12.5 13 13.5 14 14.3 15 15.5 16 16.5 16.5 Expansion
Locating Pin
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VFL
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5 VF M
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more VFJ
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 VFK
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0

Weight g 180 210 250 180 220 250 190 220 250 190 220 260 190 220 260 320 370 420 330 380 420 330 380 430 340 380 430 340 380 440 Pull Stud Clamp
FP
FQ
Customized
Spring Cylinder
DW A /DW B

970
Expansion Locating Pin Release Confirmation Model Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM2-M / VFM3-M / VFM4-M

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFM2000-MR / VFM3000-MR / VFM4000-MR.
The ports of VFM2000-ML / VFM3000-ML / VFM4000-ML are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark
2-Mounting Bolt (Included) 2-Thread for Jack Bolt

Full Stroke
φR
U V

T
EX

(Expanding Area)
S

(E)

(E)
Datum Diameter Datum Diameter

J
A (When Releasing) (At Full Stroke)

45°
45°

R
BL

O
NS
O
W

SE
.Q
P.C.D

Workpiece Hole Dimensions

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


VFM-C φWAH8 Workpiece Hole Diameter
⊥ 0.05 Y
(Cut:One Direction Locating) φWAH8
K+0.5 or more

⊥ 0.05 Y

WB or more

6.3S
View A

6.3S
1 or less

1 or less
5 Seating Height:H15

φL
φM
Expanding Area

60°

Y VFM Mounting Surface


Datum Diameter
K
E

G φN
C

◎ φ0.01 X
1

Y Notes:
B
F

※1. Identification mark is only marked on -C:Cut (for one


A

φDh6 direction locating).    indicates the locating direction.


5

X
※2. Set the O-ring to the mounting hole side (fixture side) before
1-O-ring (Included)
18

mounting the body.


W
1. When mounting the product, use two mounting bolts
1-O-ring (Included)
※2 (Strength Grade 12.9) and tighten them evenly.
W Use two jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
5 Seating Height:H20 / H25 (EXT:Air Vent Port, BLOW:Air Blow Port, SENSOR:Release
Confirmation Air Port) Continuously supply air pressure to
φL
the air blow port and release confirmation air port.
φM
3. This product has no seat. Choose option -B:with Seating
Expanding Area

60° Surface or prepare another seat if necessary.

Datum Diameter
K

Port Position
E

φN
1
C

◎ φ0.01 X Air Vent Port


R L
G
H
B

Y
A

φDh6
5

X
Release Confirmation Air Port
1-O-ring (Included)
18

W Air Blow Port

1-O-ring (Included)
※2 Note:
W 4. Please make sure that the port positions are correct.
971
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Air Vent Port 2-ME Thread 2-ME Thread Air Vent Port
Hydraulic Series
φMC φMA

Valve / Coupler
P.C.D .Q
.Q P.C.D
Hydraulic Unit

T
T
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFA
φMB φMA φMC φMB SFC
φDH7 30°
Z ⊥ 0.01 Z Swing Clamp
Must be 1.3

LHA
S

Mounting※3
6.3S

6.3

Surface Notes: LHC

※3. There might be foam near the flange bottom depending on LHS
LHW
roughness of mounting surface, but this is not a malfunction.
7.5

MF or more

LT/LG
※4. Prepare the hydraulic lock port within   .
17±0.1

TLA-2
※5. Prepare the hydraulic release port on the bottom within the
※4

TLB-2
7

range of φMD.
TLA-1
1. Make sure to check the cautions for cylinder mounting distance
accuracy, workpiece hole distance accuracy and mounting phase Link Clamp

before installation. (Refer to P.1011.) LK A


Hydraulic Lock Port ※4 Hydraulic Release Port ※5 LK C
±0.05 ※5
φMD LK W

External Dimensions and Machining Dimensions for Mounting (mm)


LM/LJ
T MA - 2
Model No. VFM2000-□-□-□-M□ VFM3000-□-□-□-M□ VFM4000-□-□-□-M□ T MA - 1

3 Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150 160 170 180 190 200 Work Support
5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LD

Workpiece Hole Diameter (Standard Diam.) φ8H8 + 0.022 φ9H8 + 0.022 φ10H8+ 0.022 φ11H8+ 0.027 φ12H8+ 0.027 φ13H8+ 0.027 φ14H8+ 0.027 φ15H8+ 0.027 φ16H8+ 0.027 φ17H8+ 0.027 φ18H8+ 0.027 φ19H8+ 0.033 φ20H8+ 00.033 LC
0 0 0 0 0 0 0 0 0 0 0 0
T NC
At Releasing φ7.94 or less φ8.94 or less φ9.94 or less φ10.94 or less φ11.92 or less φ12.92 or less φ13.92 or less φ14.92 or less φ15.89 or less φ16.89 or less φ17.89 or less φ18.89 or less φ19.89 or less
Datum Diameter TC
At Full Stroke φ8.05 or more φ9.05 or more φ10.05 or more φ11.05 or more φ12.05 or more φ13.05 or more φ14.05 or more φ15.05 or more φ16.07 or more φ17.07 or more φ18.07 or more φ19.07 or more φ20.07 or more Air Sensing
Full Stroke 0.65 0.75 1.0 Lift Cylinder
LLW
A 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41 46 51 41 46 51 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5 42.5 47.5 52.5
B 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 Compact Cylinder

C 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 LL
0 0 0 LLR
D h6 (Body Side) 15 - 0.011 15 - 0.011 18 - 0.011
LLU
+ 0.018 + 0.018 + 0.018
D H7 (Machining Hole) 15 0 15 0 18 0
DP
E 8.3 8 8 8.3 8 8 8.3 8 8 8.3 8 8 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 8.8 8.5 8.5 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 10.3 10 10 DR
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 DS
DT
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Block Cylinder

J 4.6 5.1 6 DBA


DBC
K 7.5 8 9.5
L 7.9 8.9 9.8 10.8 11.8 12.8 13.8 14.8 15.7 16.7 17.7 18.7 19.7 Centering Vise

M 6.5 7.5 8.5 9.5 10.5 11.5 12.5 13.5 14 15 16 17 18 FVA


FVD
N 14.5 9 9 14.5 10 10 14.5 11 11 14.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 22.5 17 17 22.5 18 18 22.5 19 19 22.5 20 20 22.5 21 21
FVC
P 4 4 5
Control Valve
Q 24 28 35
BZL
R 33 37 47
BZT
S 9.5 9.5 11.5 BZX/JZG
T 35° 30° 30°
Pallet Clamp
U M5×0.8×12 M5×0.8×12 M6×1×16 VS
V M6×1 M6×1 M8×1.25 VT
W AS568-013 (90°
) AS568-013 (90°) AS568-015 (90°) Expansion
CA 2.5 2.5 3 3 3.5 3.5 4 4 4.5 4.5 5 5 5 Locating Pin
VFL
CB 7.8 8.8 9.7 10.7 11.7 12.7 13.7 14.7 15.5 16.5 17.5 18.5 19.5
VF M
MA 3 3 4
VFJ
MB 3 3 4 VFK
MC 3 3 4
Pull Stud Clamp
MD 12.1 12.1 15.1
FP
ME M5×0.8 Thread Depth 9 or more M5×0.8 Thread Depth 9 or more M6×1 Thread Depth 12 or more
FQ
MF 19 19 19.5 Customized
WA  8
+ 0.022
0  9 + 0.022
0  10 + 0.022
0
+ 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027 + 0.027
 11 0  12 0  13 0  14 0  15 0  16 0  17 0  18 0  19 0  20 0
+ 0.027 + 0.033 + 0.033 Spring Cylinder
DW A /DW B
WB 4 4.5 5.5
Weight g 80 90 110 80 90 110 80 90 110 80 100 110 90 110 130 90 110 130 90 110 130 100 110 130 150 170 200 150 180 200 150 180 200 150 180 210 150 180 210 972
Expansion Locating Pin Release Confirmation Model Locating Repeatability:3μm Hyd. Lock/Hyd. Release model VFM5-M / VFM6-M

External Dimensions Expanding Area Detail


※ The drawing shows the released state of VFL5000-MR / VFL6000-MR.
The ports of VFL5000-ML / VFL6000-ML are placed to the symmetrical
positions of this drawing. When Releasing When Locking (At Full Stroke)
※1
Identification Mark

φR
3-Mounting Bolt (Included) 3-Thread for Jack Bolt

7.5 (Expanding Area)


U V

Full Stroke
S

(E)

(E)
Datum Diameter Datum Diameter
A (When Releasing) (At Full Stroke)

30°
30°

BL

CK
OW

LO
EX OR °
30

T NS
SE
30
°

.Q

Workpiece Hole Dimensions


P.C.D

Blind Hole Through Hole


φCB
CA

Workpiece Hole Diameter


φWAH8 Workpiece Hole Diameter
⊥ 0.05 ZB
φWAH8
VFM-C ⊥ 0.05 ZB
12.5 or more

6.3S
(Cut:One Direction Locating)

7 or more
6.3S
View A
1 or less

1 or less
φL
φM
Expanding Area

60°

ZB VFM Mounting Surface


Datum Diameter
12
7.5
E

φN
C

◎ φ0.01 ZA
1.5

G
A

ZB Notes:
B
F

※1. Identification mark is only marked on -C:Cut (for one


P

φDh6
direction locating).    indicates the locating direction.
5

ZA
8

1-O-ring (Included)
1. When mounting the product, use three mounting bolts
BC
(Strength Grade 12.9) and tighten them evenly.
1-O-ring (Included)
W Use three jack bolts to remove the product, keeping it
parallel to the mounting surface.
2. The port name is marked on the product surface.
(EXT:Air Vent Port, BLOW:Air Blow Port,
SENSOR:Release Confirmation Air Port, LOCK:Air Lock Port)
Continuously supply air pressure to the air blow port and
release confirmation air port.
3. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.

Port Position
R L
Hydraulic Lock Port

Release Confirmation Air Port

Air Vent Port

Air Blow Port


Note:
4. Please make sure that the port positions are correct.
973
Expansion Locating Pin Action System Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest Description References (VFL) (VFL) (VFM) (VFM) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

.Q

P.C.D
Hydraulic Series

P.C.D

.Q
Air Blow Port 3-ME Thread 3-ME Thread Air Blow Port
Valve / Coupler
φ4 φ4
Hydraulic Unit

Manual Operation
Accessories

Cautions / Others

30°
30°

30°
30°
Hole Clamp

°
°
30

30

30
SFA
Hydraulic Lock Port Hydraulic Lock Port
30
°

°
SFC
φ4 φ4
Air Vent Port Release Confirmation Air Port Release Confirmation Air Port Air Vent Port Swing Clamp

φ4 φ4 φ4 φ4 LHA
LHC

30° LHS
φDH7 ⊥ 0.01 ZC Notes:
ZC LHW
Must be 1.3

※2. There might be foam near the flange bottom depending on LT/LG
S

Mounting※2
6.3S

6.3

Surface roughness of mounting surface, but this is not a malfunction. TLA-2


8.5 or more

※3. Prepare the hydraulic release port on the bottom within the TLB-2
range of φDH7. TLA-1
1. Make sure to check the cautions for cylinder mounting distance
Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
LK A
before installation. (Refer to P.1011.) LK C
LK W
※3
Hydraulic Release Port LM/LJ
T MA - 2
T MA - 1

Work Support

External Dimensions and Machining Dimensions for Mounting (mm)


LD
LC
Model No. VFM5000-□-□-M□ VFM6000-□-□-M□ T NC
3 Workpiece Hole Diam. Code 210 220 230 240 250 260 270 280 290 300 TC

5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 H20 H25 H30 Air Sensing
Lift Cylinder
Workpiece Hole Diameter (Standard Diam.) φ21H8 +0.033
0 φ22H8 +0.033
0 φ23H8 +0.033
0 φ24H8 +00.033 φ25H8 +00.033 φ26H8 +00.033 φ27H8 +00.033 φ28H8 +00.033 φ29H8 +00.033 φ30H8 +0.033
0
LLW
At Releasing φ20.89 or less φ21.89 or less φ22.89 or less φ23.89 or less φ24.89 or less φ25.89 or less φ26.89 or less φ27.89 or less φ28.89 or less φ29.89 or less
Datum Diameter Compact Cylinder
At Full Stroke φ21.07 or more φ22.07 or more φ23.07 or more φ24.07 or more φ25.07 or more φ26.07 or more φ27.07 or more φ28.07 or more φ29.07 or more φ30.07 or more
LL
Full Stroke 1 LLR
A 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 40 45 50 40 45 50 40 45 50 40 45 50 40 45 50 LLU

B 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 10.5 15.5 20.5 14.5 20 25 14.5 20 25 14.5 20 25 14.5 19.5 24.5 14.5 19.5 24.5 DP
DR
C 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 3.7 4 4 4.7 4.5 4.5 4.7 4.5 4.5 4.7 4.5 4.5 4.7 5 5 4.7 5 5
DS
0 0
D h6 (Body Side) 24 - 0.013 29 - 0.013 DT
+ 0.021 + 0.021
D H7 (Machining Hole) 24 0 29 0
Block Cylinder
E 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 12.8 12.5 12.5 DBA
F 8 11 11 8 11 11 8 11 11 8 11 11 8 11 11 11 14 14 11 14 14 11 14 14 11 14 14 11 14 14 DBC
G 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30° 8° 15° 30°
Centering Vise
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 20 25 30 20 25 30 20 25 30 20 25 30 20 25 30
FVA
L 20.7 21.7 22.7 23.7 24.7 25.7 26.7 27.7 28.7 29.7 FVD
M 19 20 21 22 23 24 25 26 27 28 FVC

N 27.5 22 22 27.5 23 23 27.5 24 24 27.5 25 25 27.5 26 26 32.5 27 27 32.5 28 28 32.5 29 29 32.5 30 30 32.5 31 31 Control Valve
P 5 6 BZL
Q 40 48 BZT
BZX/JZG
R 51 62
S 14 16.5 Pallet Clamp

U M6×1×16 M8×1.25×20 VS
VT
V M8×1.25 M10×1.5
W AS568-019 (90°) AS568-022 (90°) Expansion
Locating Pin
BC AS568-007 (90°) 1BP5 VFL
CA 5.5 5.5 6 6 6 6.5 6.5 7 7 7 VF M
CB 20.5 21.5 22.5 23.5 24.5 25.5 26.5 27.5 28.5 29.5 VFJ
VFK
ME M6×1 Thread Depth 12 or more M8×1.25 Thread Depth 15 or more
+ 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033 + 0.033
WA 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 Pull Stud Clamp
Weight g 180 210 250 180 220 250 190 220 250 190 220 260 190 220 260 320 370 420 330 380 420 330 380 430 340 380 430 340 380 440 FP
FQ
Customized
Spring Cylinder
DW A /DW B

974
Expansion Locating Pin Locating Repeatability:10μm model VFJ/V F K

PAT.

Hydraul ic
E xpans ion L oc atin g P i n
Model VFJ/VFK
Hydraulic・Single Action/Double Action

Locating Repeatability:10μm

Index

Expansion Locating Pin Digest P.937

Action Description P.976

VFJ Model No. Indication P.977

VFJ Specifications P.979

VFJ External Dimensions

・ Standard P.981

・ with Seating Surface P.985

・ Release Confirmation Model P.989

VFK Model No. Indication P.993

VFK Specifications P.995

VFK External Dimensions

・ Standard P.997

・ with Seating Surface P.1001

・ Release Confirmation Model P.1005

Cautions

・ Notes for Hydraulic Expansion Locating Pin P.1009

・ Cautions (Common) P.1237


・Notes on Hydraulic Cylinder Speed Control Circuit
・Hydraulic Fluid List
・Notes on Handling ・Maintenance/Inspection ・Warranty

975
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Action Description This is a simplified drawing of VFJ / VFK (Standard). Series

Pneumatic Series
model VFJ model VFK
Hydraulic Series
Steel Ball
Steel Ball Valve / Coupler
Stopper Hydraulic Unit
Stopper
Manual Operation
Mounting Bolt Body Accessories
Mounting Bolt Body

Cautions / Others

Hole Clamp
SFA
SFC
Air Blow Port
Air Blow Port Swing Clamp

Release Spring LHA

Base Plate LHC

Hydraulic Lock Port LHS


Piston Rod Hydraulic Release Port LHW
LT/LG
Base Plate
TLA-2
Hydraulic Lock Port Piston Rod
TLB-2
TLA-1

Link Clamp
LK A
About Reference Locating and Orientation LK C
LK W
Steel Ball (3 Parts) Steel Ball (2 Parts) LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
VFJ/VFK- D:Datum V FJ/V FK - C:Cut
LLW
Reference Locating One Direction Locating
Compact Cylinder
LL
model VFJ model VFK LLR
LLU
DP
Workpiece Workpiece
・ VFJ:When lock hydraulic pressure is OFF, DR
the piston rod descends and steel balls are free to move. DS

・ VFK:When lock hydraulic pressure is OFF and release DT


Seat
Seat hydraulic pressure is ON, the piston rod descends and Block Cylinder
steel balls are free to move. DBA
DBC
・ Air blow prevents debris contamination.
※It is not a malfunction when the steel balls are expanded with Centering Vise
air blow pressure. FVA
Air Blow
Air Blow FVD
ON
ON FVC
When loading workpiece When unloading workpiece
Base Plate Lock Hydraulic Pressure Control Valve
Release Hydraulic Pressure
OFF ON BZL
Base Plate Lock Hydraulic Pressure BZT
OFF BZX/JZG

Pallet Clamp
VS
VT

When locating Expansion


Locating Pin
VFL
VFM
・ VFJ:When lock hydraulic pressure is ON, the piston rod VF J
VF K
is ascended and the steel balls are expanded to locate
the workpiece. Pull Stud Clamp
・ VFK:When release hydraulic pressure is OFF and lock Air Blow
FP
ON
hydraulic pressure is ON, the piston rod is ascended and FQ
Air Blow Customized
ON the steel balls are expanded to locate the workpiece.
Release Hydraulic Pressure Spring Cylinder
(Another seat is required for standard and release confirmation models.) OFF DW A /DW B
Lock Hydraulic Pressure
Lock Hydraulic Pressure
ON
ON 976
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ

Model No. Indication

VFJ 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7

1 Body Size

2 : Select from Workpiece Hole Diameter φ7.6∼φ10.8


3 : Select from Workpiece Hole Diameter φ10.4∼φ16.2

2 Design No.

0 :Revision Number

3 Workpiece Hole Diameter

Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150
Workpiece Hole Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8 φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
Diameter (mm) Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8 φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
VFJ2000 Selection Range
VFJ3000 Selection Range

Straight Hole Taper Hole


Slope Angle
Workpiece Hole Diameter 2.5°or less

Workpiece Hole Diameter

4 Functions

D :Datum (for Reference Locating) D C Steel Ball

C :Cut (for One Direction Locating)

Datum Cut

5 Seating Height

H15 :15mm
Seating Height

Note:
H20 :20mm
Prepare the seat separately for 6 Option Blank:Standard
H25 :25mm and M:Release Confirmation Model.

977
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Series

Pneumatic Series

Hydraulic Series

Valve / Coupler
Hydraulic Unit

Manual Operation
Accessories

6 Options Cautions / Others

Blank :None (Standard)


Hole Clamp
Note:
B :with Seating Surface SFA
Contact us for combined use of B:with Seating Surface SFC
M :Release Confirmation Model and M:Release Confirmation model.
Swing Clamp
LHA
LHC
LHS

7 Port Position Only for 6 Options:B (with Seating Surface), and M (Release Confirmation Model) LHW
LT/LG
R Vent Port Vent Port L TLA-2
R :As Illustrated TLB-2
Only for 6 M Only for 6 M TLA-1
L :As Illustrated
Link Clamp
LK A
Air Blow Port Air Blow Port LK C
LK W
Air Port Air Port LM/LJ
6 B :Seating Confirmation 6 B :Seating Confirmation T MA - 2
T MA - 1
6 M:Release Confirmation 6 M:Release Confirmation
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VFL
VFM
VF J
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

978
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ

Specifications:VFJ2000
Model No. VFJ2000-080 VFJ2000-090 VFJ2000-100
Workpiece Hole Diameter Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8
mm Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.4 ±0.4 ±0.5
at 2.5MPa 50
Expanding Force (F) ※2
at 5.0MPa 130
N
at 7.0MPa 190
Allowable Thrust Load ※3 N 450 600 800
Cylinder Capacity (Empty Action) cm3 0.08 0.10 0.12
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Specifications:VFJ3000
Model No. VFJ3000-110 VFJ3000-120 VFJ3000-130 VFJ3000-140 VFJ3000-150
Workpiece Hole Diameter Straight Hole φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
mm Taper Hole φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.6 ±0.6 ±0.7 ±0.7 ±0.8
at 2.5MPa 130
Expanding Force (F) ※2
at 5.0MPa 290
N
at 7.0MPa 420
Allowable Thrust Load ※3 N 1000 1000 1300 1300 1800
Cylinder Capacity (Empty Action) cm3 0.29 0.29 0.32 0.32 0.36
Operating Pressure Range MPa 2.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Notes:
※1. It shows locating repeatability under the specific condition (no load).
※2. Expanding force shows the calculated value when coefficient friction is μ0.1.
Refer to the next page for the relative equation of expanding force and allowable workpiece weight for locating.
※3. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates with hydraulic pressure and releases with spring. (Hydraulic Pressure Single Action)
2. This cylinder is used only for locating and does not have a clamping function.

979
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating Series

Pneumatic Series

Hydraulic Series
F W
F
Horizontal Attitude μ Vertical Attitude Valve / Coupler
Hydraulic Unit
Seat
W Manual Operation
Accessories

Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5 Cautions / Others
Workpiece Weight (W) ≦ Workpiece Weight (W) ≦ Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5
Friction Coefficient of Workpiece Seat Face (μ)
Hole Clamp
SFA
SFC

Swing Clamp
LHA
LHC
LHS
LHW
LT/LG
TLA-2
TLB-2
TLA-1

Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VFL
VFM
VF J
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

980
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ2

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFJ2000 clamping action without workpiece.

Straight Hole Taper Hole

Workpiece Hole Diameter


2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt Slope Angle

φ3
φWA
M5×0.8×12 R2 or less 2.5°or less

K+0.5 or more
K+0.5 or more
19

2 or less
Workpiece Hole Diameter
φWC

12 12

VFJ Mounting Surface


CD
CB
CA
CC
CB

VFJ-C
(Cut:One Direction Locating)
Notes:
※1. Do not use spring washer or toothed lock washer.
5 Seating Height:H15 1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Datum Diameter Use two jack bolts to remove the product, keeping it
φL g8 VFJ-C:Cut parallel to the mounting surface.
Steel Ball J φM 2. This product has no seat. Choose option -B:with Seating

60° Surface or prepare another seat if necessary.


K
E

3.5

G φN
C

◎ φ0.02 X
1

※1
H
A
B
F

φ15g7 -- 0.006
5

0.024
X
10.5

1-O-ring (Included)
AS568-013 (90° )

5 Seating Height:H20 / H25

Datum Diameter
φL g8 VFJ-C:Cut
Steel Ball J φM

60°
K
E

3.5

φN
C

◎ φ0.02 X
1

G
H
A

※1
B
F

φ15g7 -- 0.006
5

0.024
X
10.5

1-O-ring (Included)
AS568-013 (90° )

981
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

2-M5×0.8 Thread Depth 9 or more Hydraulic Series


12 12
Valve / Coupler
Hydraulic Unit
★ ★
Manual Operation
Accessories
6.5

★ ★ Cautions / Others

※2
Air Blow Port 10.5 Hole Clamp
φ3 SFA
SFC

Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※2. Install the air blow port choosing one port from four ★ parts.
Z LHW
※3. There might be foam near the flange bottom depending on
Must be 1.3

LT/LG
※3
S
6.3S

roughness of mounting surface, but this is not a malfunction.


6.3

Mounting TLA-2
Surface
※4. Prepare the hydraulic lock port on the bottom within the range TLB-2
11 or more

TLA-1
of φ15.
1. Make sure to check the cautions for cylinder mounting distance Link Clamp

accuracy, workpiece hole distance accuracy and mounting phase LK A


LK C
before installation. (Refer to P.1011.)
LK W
※4
※4 Hydraulic Lock Port LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFJ2000-080-□-□ VFJ2000-090-□-□ VFJ2000-100-□-□ Compact Cylinder



3 Workpiece Hole Diam. Code 080 090 100 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT

Cylinder Stroke 1.8 2.2 2.6 Block Cylinder


A 33 38 43 33.5 38.5 43.5 34 39 44 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 Centering Vise


E 8.3 8 8 8.8 8.5 8.5 9.3 9 9 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 Control Valve

J 2.5 3 3.5 BZL


BZT
K 7.5 8 8.5
BZX/JZG
- 0.005 - 0.005 - 0.005
L 7.5 - 0.027 8.3 - 0.027 9.3 - 0.027
Pallet Clamp
M 5.5 6 6.5
VS
N 14.5 9 9 14.5 10 10 14.5 11 11 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VF J
Weight g 60 70 80 60 70 80 60 70 90
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

982
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ3

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFJ3000 clamping action without workpiece.

Straight Hole Taper Hole

Workpiece Hole Diameter Slope Angle


2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt
φWA 2.5°or less
M5×0.8×12

φ3
R2 or less

K+0.5 or more
K+0.5 or more
7

2 or less
23

Workpiece Hole Diameter


φWC

14 14

CD
CB

VFJ Mounting Surface


CA
CC
CB

VFJ-C Notes:
(Cut:One Direction Locating) ※1. Do not use spring washer or toothed lock washer.
1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Datum Diameter Use two jack bolts to remove the product, keeping it
φL g8 parallel to the mounting surface.
φM VFJ-C:Cut 2. This product has no seat. Choose option -B:with Seating

60° Surface or prepare another seat if necessary.


Steel Ball J
K
E

1 3.5

φN
C

◎ φ0.02 X
G
H

※1
B
A

φ19g7 -- 0.028
0.007
5

X
16.5

1-O-ring (Included)
AS568-016 (90° )

983
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

14 14 2-M5×0.8 Thread Depth 9 or more Hydraulic Series

Valve / Coupler
★ Hydraulic Unit

★ Manual Operation
Accessories


7.5

★ Cautions / Others

※2 Hole Clamp
Air Blow Port 12.5
SFA
φ3
SFC

Swing Clamp
LHA
⊥ 0.01 Z LHC
Notes: LHS
φ19H7 +0.021
0 30°
Z ※2. Install the air blow port choosing one port from four ★ parts. LHW
Must be 1.3

※3. There might be foam near the flange bottom depending on LT/LG
※3
S
6.3S

6.3

Mounting TLA-2
Surface roughness of mounting surface, but this is not a malfunction.
TLB-2
※4. Prepare the hydraulic lock port on the bottom within the range of TLA-1
17 or more
8

φ19, or within   .
Link Clamp
1. Make sure to check the cautions for cylinder mounting distance
LK A
accuracy, workpiece hole distance accuracy and mounting phase LK C
before installation. (Refer to P.1011.) LK W
LM/LJ
※4 T MA - 2
Hydraulic Lock Port
0 ※4 T MA - 1
φ19 -  
0.2

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFJ3000-110-□-□ VFJ3000-120-□-□ VFJ3000-130-□-□ VFJ3000-140-□-□ VFJ3000-150-□-□ Compact Cylinder



3 Workpiece Hole Diam. Code 110 120 130 140 150 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT

Cylinder Stroke 3 3 3.4 3.4 3.8 Block Cylinder


A 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41.5 46.5 51.5 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve

J 4 4 4.5 4.5 5 BZL


BZT
K 9 9 9.5 9.5 10
BZX/JZG
- 0.006 - 0.006 - 0.006 - 0.006 - 0.006
L 10.2 - 0.033 11.2 - 0.033 12.0 - 0.033 13.0 - 0.033 13.8 - 0.033
Pallet Clamp
M 7.4 8.4 9.2 10.2 11.0
VS
N 18.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL

CD R4.5 R5 R5.3 R5.8 R6.1 VFM


VF J
Weight g 100 110 130 100 110 130 100 120 130 100 120 130 100 120 130
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

984
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ 2-B

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFJ2000-BR clamping action without workpiece.
The ports of VFJ2000-BL are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter


2-Mounting Bolt(Included) BA 2-M6×1 Thread for Jack Bolt Slope Angle

φ3
φWA
M5×0.8×12 R2 or less 2.5°or less

K+0.5 or more
K+0.5 or more
9.5

※1

2 or less
Workpiece Hole Diameter
φWC

45°
45°

BL

FC
O
W

. 24
BB

P.C.D

Seating Confirmation Air Hole


φ1.5

VFJ Mounting Surface


CD
CB
CA
CC
CB

VFJ-C
(Cut:One Direction Locating)
Notes:
※1. Please note that if the chamfer of the workpiece hole end is
5 Seating Height:H15 large, the seating confirmation air may not be increased.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 VFJ-C:Cut Use two jack bolts to remove the product, keeping it
Steel Ball J φM parallel to the mounting surface.

60° 2. The port name is marked on the product surface.


(BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
K

3.5

seating confirmation air port.


G φN
C

◎ φ0.02 X
H±0.03
A

φ15g7 -- 0.006
5

0.024
X 1-O-ring (Included)
10.5

AS568-006 (90° )
1-O-ring (Included)
AS568-013 (90° )
Port Position
R Seating Confirmation Air Hole L

5 Seating Height:H20 / H25

Datum Diameter
φL g8 VFJ-C:Cut
Seating Confirmation Air Port
Steel Ball J φM

60° Air Blow Port

Note:
K

3. Please make sure that the port positions are correct.


3.5

φN
C

◎ φ0.02 X
G
H±0.03
A

φ15g7 -- 0.006
5

0.024
X 1-O-ring (Included)
10.5

AS568-006 (90° )
1-O-ring (Included)
AS568-013 (90° )

985
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
Hydraulic Unit
P.C.D 24
. 24 P .C.D.
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※2. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3

LT/LG
※2
S
6.3S

Mounting ※3. Prepare the hydraulic lock port on the bottom within the range
6.3

TLA-2
Surface
of φ15. TLB-2
11 or more

1. Make sure to check the cautions for cylinder mounting distance TLA-1

accuracy, workpiece hole distance accuracy and mounting phase Link Clamp

before installation. (Refer to P.1011.) LK A


LK C
LK W
※3
※3 Hydraulic Lock Port LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFJ2000-080-□-□-B□ VFJ2000-090-□-□-B□ VFJ2000-100-□-□-B□ Compact Cylinder



3 Workpiece Hole Diam. Code 080 090 100 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT

Cylinder Stroke 1.8 2.2 2.6 Block Cylinder


A 33 38 43 33.5 38.5 43.5 34 39 44 DBA

C 4 4 4 4 4 4 4 4 4 DBC

F 9 9 9.5 9 9 9.5 9 9 9.5 Centering Vise


G 8° 25° 40° 8° 25° 40° 8° 25° 40° FVA
H 15 20 25 15 20 25 15 20 25 FVD
FVC
J 2.5 3 3.5
K 7.5 8 8.5 Control Valve

L 7.5 - 0.005
8.3 - 0.005
9.3 - 0.005 BZL
- 0.027 - 0.027 - 0.027
BZT
M 5.5 6 6.5
BZX/JZG
N 15.5 15.5 15.5 16.5 16.5 16.5 17.5 17.5 17.5
Pallet Clamp
BA 12 13 14
VS
BB 6 6.5 7 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VF J
Weight g 70 80 100 70 80 100 70 80 100
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

986
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ 3-B

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFJ3000-BR clamping action without workpiece.
The ports of VFJ3000-BL are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter Slope Angle

φ
2-Mounting Bolt (Included) BA 2-M6×1 Thread for Jack Bolt 2.5°or less
37
φWA
M5×0.8×12 R2 or less

K+0.5 or more
K+0.5 or more
11.5

※1

2 or less
Workpiece Hole Diameter
φWC

45°
45°

BL

FC
O
W

. 28
P.C.D
BB

Seating Confirmation Air Hole


φ1.5

CD VFJ Mounting Surface


CB
CA
CC
CB

VFJ-C Notes:
(Cut:One Direction Locating) ※1. Please note that if the chamfer of the workpiece hole end is
large, the seating confirmation air may not be increased.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 Use two jack bolts to remove the product, keeping it
φM VFJ-C:Cut parallel to the mounting surface.

60° 2. The port name is marked on the product surface.


Steel Ball J
(BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
Continuously supply air pressure to the air blow port and
seating confirmation air port.
K

3.5

φN
◎ φ0.02 X
C

G
H±0.03
A

φ19g7 -- 0.028
0.007
5

X 1-O-ring (Included)
AS568-006 (90° )
16.5

1-O-ring (Included)
AS568-016 (90° )
Port Position
R Seating Confirmation Air Hole L

Seating Confirmation Air Port

Air Blow Port

Note:
3. Please make sure that the port positions are correct.

987
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
P.C.D 8 Hydraulic Unit
.2
. 28 P.C.D
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ19H7 +0.021
0 30° ※2. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3

LT/LG
※2
S
6.3S

※3. Prepare the hydraulic lock port on the bottom within the range of
6.3

Mounting TLA-2
Surface
φ19, or within   . TLB-2

1. Make sure to check the cautions for cylinder mounting distance TLA-1
17 or more
8

accuracy, workpiece hole distance accuracy and mounting phase Link Clamp

before installation. (Refer to P.1011.) LK A


LK C
LK W
LM/LJ
※3 T MA - 2
Hydraulic Lock Port
0 ※3 T MA - 1
φ19 -  
0.2

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFJ3000-110-□-□-B□ VFJ3000-120-□-□-B□ VFJ3000-130-□-□-B□ VFJ3000-140-□-□-B□ VFJ3000-150-□-□-B□ Compact Cylinder



3 Workpiece Hole Diam. Code 110 120 130 140 150 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT

Cylinder Stroke 3 3 3.4 3.4 3.8 Block Cylinder


A 40.5 45.5 50.5 40.5 45.5 50.5 41 46 51 41 46 51 41.5 46.5 51.5 DBA

C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 DBC

F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 Centering Vise


G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° FVA
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 FVD
FVC
J 4 4 4.5 4.5 5
K 9 9 9.5 9.5 10 Control Valve

L 10.2 -- 0.006 11.2 -- 0.006 12.0 -- 0.006 13.0 -- 0.006 13.8 -- 0.006 BZL
0.033 0.033 0.033 0.033 0.033
BZT
M 7.4 8.4 9.2 10.2 11.0
BZX/JZG
N 19.5 19.5 19.5 20.5 20.5 20.5 21.5 21.5 21.5 22.5 22.5 22.5 23.5 23.5 23.5
Pallet Clamp
BA 15 16 17 17 18
VS
BB 8 8.5 9 9.5 10 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL

R4.5 R5 R5.3 R5.8 R6.1 VFM


CD
VF J
Weight g 110 120 140 110 130 140 110 130 140 110 130 150 110 130 150
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

988
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ2-M

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFJ2000-MR clamping action without workpiece.
The ports of VFJ2000-ML are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter


2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt Slope Angle

φ3
φWA
M5×0.8×12 R2 or less 2.5°or less

K+0.5 or more
K+0.5 or more
T

35°
EX
9.5

2 or less
Workpiece Hole Diameter
φWC

45°
45°

R
BL

O
NS
O
W

SE
. 24
P.C.D

VFJ Mounting Surface


CD
CB
CA
CC
CB

VFJ-C
(Cut:One Direction Locating)
Notes:
1. When mounting the product, use two mounting bolts
5 Seating Height:H15 (Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
Datum Diameter parallel to the mounting surface.
φL g8 VFJ-C:Cut 2. The port name is marked on the product surface.
Steel Ball J φM (EXT:Air Vent Port, BLOW:Air Blow Port,

60° SENSOR:Release Confirmation Air Port)


Continuously supply air pressure to the air blow port and
release confirmation air port.
K
E

3.5

3. This product has no seat. Choose option -B:with Seating


G φN
Surface or prepare another seat if necessary.
C

◎ φ0.02 X
1
H
B
F
A

φ15g7 -- 0.006
5

0.024
X
16

1-O-ring (Included)
AS568-013 (90° )

Port Position
R Air Vent Port L

5 Seating Height:H20 / H25

Datum Diameter
φL g8 VFJ-C:Cut
Release Confirmation Air Port
Steel Ball J φM

60° Air Blow Port

Note:
K

4. Please make sure that the port positions are correct.


E

3.5

φN
C

◎ φ0.02 X
1

G
H
B
A

φ15g7 -- 0.006
5

0.024
X
16

1-O-ring (Included)
AS568-013 (90° )

989
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Air Vent Port 2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more Air Vent Port Hydraulic Series
φ3 φ3
Valve / Coupler
Hydraulic Unit

35°
P.C.D 24

35°
. 24 P .C.D.
Manual Operation
Accessories

Cautions / Others

45°

45°
45°
45°

Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※1. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3

LT/LG
※1
S
6.3S

Mounting ※2. Prepare the hydraulic lock port on the bottom within the range
6.3

TLA-2
Surface
of φ15. TLB-2
TLA-1
16.5 or more

1. Make sure to check the cautions for cylinder mounting distance


accuracy, workpiece hole distance accuracy and mounting phase Link Clamp

before installation. (Refer to P.1011.) LK A


LK C
LK W
LM/LJ
※2 T MA - 2
※2 Hydraulic Lock Port
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFJ2000-080-□-□-M□ VFJ2000-090-□-□-M□ VFJ2000-100-□-□-M□ Compact Cylinder



3 Workpiece Hole Diam. Code 080 090 100 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT

Cylinder Stroke 1.8 2.2 2.6 Block Cylinder


A 38.5 43.5 48.5 39 44 49 39.5 44.5 49.5 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 Centering Vise


E 8.3 8 8 8.8 8.5 8.5 9.3 9 9 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 Control Valve

J 2.5 3 3.5 BZL


BZT
K 7.5 8 8.5
BZX/JZG
- 0.005 - 0.005 - 0.005
L 7.5 - 0.027 8.3 - 0.027 9.3 - 0.027
Pallet Clamp
M 5.5 6 6.5
VS
N 14.5 9 9 14.5 10 10 14.5 11 11 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VF J
Weight g 70 100 110 70 100 110 80 100 110
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

990
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Spring Release m od e l VFJ3-M

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFJ3000-MR clamping action without workpiece.
The ports of VFJ3000-ML are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter Slope Angle

φ
2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt φWA 2.5°or less

37
M5×0.8×12 R2 or less

K+0.5 or more
K+0.5 or more
T
EX

35°
11.5

2 or less
Workpiece Hole Diameter
φWC

45°
45°

R
BL

O
NS
O
W

SE
. 28
P.C.D

CD VFJ Mounting Surface


CB
CA
CC
CB

VFJ-C Notes:
(Cut:One Direction Locating) 1. When mounting the product, use two mounting bolts
(Strength Grade 12.9) and tighten them evenly.
Use two jack bolts to remove the product, keeping it
Datum Diameter parallel to the mounting surface.
φL g8 2. The port name is marked on the product surface.
φM VFJ-C:Cut (EXT:Air Vent Port, BLOW:Air Blow Port,

60° SENSOR:Release Confirmation Air Port)


Steel Ball J
Continuously supply air pressure to the air blow port and
release confirmation air port.
3. This product has no seat. Choose option -B:with Seating
K
E

Surface or prepare another seat if necessary.


1 3.5

φN
C

◎ φ0.02 X
G
H
B
F
A

4
7.5

φ19g7 -- 0.007
0.028
X
1-O-ring (Included)
24

AS568-016 (90° )
Port Position
R Air Vent Port L

Release Confirmation Air Port

Air Blow Port

Note:
4. Please make sure that the port positions are correct.

991
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Air Vent Port Air Vent Port


2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more Hydraulic Series
φ3 φ3

Valve / Coupler
P.C.D Hydraulic Unit

35°
28

35°
. 28 P.C.D.
Manual Operation
Accessories

Cautions / Others

45°

45°
45°
45°

Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ19H7 +0.021
0 30° ※1. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3

LT/LG
※1
S

※2. Prepare the hydraulic lock port on the bottom within the range of
6.3S

6.3

Mounting TLA-2
Surface
φ19, or within   . TLB-2

1. Make sure to check the cautions for cylinder mounting distance TLA-1
10.5

accuracy, workpiece hole distance accuracy and mounting phase


24.5 or more

Link Clamp
before installation. (Refer to P.1011.) LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1

※2 Work Support
Hydraulic Lock Port
0 ※2 LD
φ19 -  
0.2
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFJ3000-110-□-□-M□ VFJ3000-120-□-□-M□ VFJ3000-130-□-□-M□ VFJ3000-140-□-□-M□ VFJ3000-150-□-□-M□ Compact Cylinder



3 Workpiece Hole Diam. Code 110 120 130 140 150 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT

Cylinder Stroke 3 3 3.4 3.4 3.8 Block Cylinder


A 48 53 58 48 53 58 48.5 53.5 58.5 48.5 53.5 58.5 49 54 59 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve

J 4 4 4.5 4.5 5 BZL


BZT
K 9 9 9.5 9.5 10
BZX/JZG
- 0.006 - 0.006 - 0.006 - 0.006 - 0.006
L 10.2 - 0.033 11.2 - 0.033 12.0 - 0.033 13.0 - 0.033 13.8 - 0.033
Pallet Clamp
M 7.4 8.4 9.2 10.2 11.0
VS
N 18.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL

CD R4.5 R5 R5.3 R5.8 R6.1 VFM


VF J
Weight g 150 170 190 150 170 190 150 170 190 150 170 190 160 170 190
VFK

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

992
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK

Model No. Indication

VFK 2 00 0 - 080 - D - H 2 0 - M R
1 2 3 4 5 6 7

1 Body Size

2 : Select from Workpiece Hole Diameter φ7.6∼φ10.8


3 : Select from Workpiece Hole Diameter φ10.4∼φ16.2

2 Design No.

0 :Revision Number

3 Workpiece Hole Diameter

Workpiece Hole Diam. Code 080 090 100 110 120 130 140 150
Workpiece Hole Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8 φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
Diameter (mm) Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8 φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
VFK2000 Selection Range
VFK3000 Selection Range

Straight Hole Taper Hole


Slope Angle
Workpiece Hole Diameter 2.5°or less

Workpiece Hole Diameter

4 Functions

D :Datum (for Reference Locating) D C Steel Ball

C :Cut (for One Direction Locating)

Datum Cut

5 Seating Height

H15 :15mm
Seating Height

Note:
H20 :20mm
Prepare the seat separately for 6 Option Blank:Standard
H25 :25mm and M:Release Confirmation Model.

993
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Series

Pneumatic Series

Hydraulic Series

Valve / Coupler
Hydraulic Unit

Manual Operation
Accessories

6 Options Cautions / Others

Blank :None (Standard)


Hole Clamp
Note:
B :with Seating Surface SFA
Contact us for combined use of B:with Seating Surface SFC
M :Release Confirmation Model and M:Release Confirmation model.
Swing Clamp
LHA
LHC
LHS

7 Port Position Only for 6 Options:B (with Seating Surface), and M (Release Confirmation Model) LHW
LT/LG
R Vent Port Vent Port L TLA-2
R :As Illustrated TLB-2
Only for 6 M Only for 6 M TLA-1
L :As Illustrated
Link Clamp
LK A
Air Blow Port Air Blow Port LK C
LK W
Air Port Air Port LM/LJ
6 B :Seating Confirmation 6 B :Seating Confirmation T MA - 2
T MA - 1
6 M:Release Confirmation 6 M:Release Confirmation
Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VFL
VFM
VFJ
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

994
Expansion Locating Pin Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK

Specifications:VFK2000
Model No. VFK2000-080 VFK2000-090 VFK2000-100
Workpiece Hole Diameter Straight Hole φ7.6 ∼φ8.5 φ8.5 ∼φ9.5 φ9.5 ∼φ10.8
mm Taper Hole φ8 ∼φ8.5 φ9 ∼φ9.5 φ10 ∼φ10.8
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.4 ±0.4 ±0.5
at 1.5MPa 50
Expanding Force (F) ※2
at 5.0MPa 150
N
at 7.0MPa 210
Allowable Thrust Load ※3 N 450 600 800
Cylinder Capacity Release side 0.03 0.04 0.04
(Empty Action) cm3 Lock side 0.08 0.10 0.12
Operating Pressure Range MPa 1.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Specifications:VFK3000
Model No. VFK3000-110 VFK3000-120 VFK3000-130 VFK3000-140 VFK3000-150
Workpiece Hole Diameter Straight Hole φ10.4 ∼φ12 φ11.4 ∼φ13 φ12.2 ∼φ14.1 φ13.2 ∼φ15.1 φ14 ∼φ16.2
mm Taper Hole φ11 ∼φ12 φ12 ∼φ13 φ13 ∼φ14.1 φ14 ∼φ15.1 φ15 ∼φ16.2
Locating Repeatability ※1 mm 0.01
Allowable Offset (C:Cut) mm ±0.6 ±0.6 ±0.7 ±0.7 ±0.8
at 1.5MPa 100
Expanding Force (F) ※2
at 5.0MPa 330
N
at 7.0MPa 460
Allowable Thrust Load ※3 N 1000 1000 1300 1300 1800
Cylinder Capacity Release side 0.11 0.11 0.13 0.13 0.15
(Empty Action) cm3 Lock side 0.29 0.29 0.32 0.32 0.36
Operating Pressure Range MPa 1.5 ∼ 7.0
Withstanding Pressure MPa 10.5
Recommended Air Blow Pressure MPa 0.3 ∼ 0.4
Operating Temperature Range ℃ 0 ∼ 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32

Notes:
※1. It shows locating repeatability under the specific condition (no load).
※2. Expanding force shows the calculated value when coefficient friction is μ0.1.
Refer to the next page for the relative equation of expanding force and allowable workpiece weight for locating.
※3. Exceeding allowable thrust load leads to accuracy failure and/or damages on the product.
1. This product locates and releases with hydraulic pressure. (Hydraulic Pressure Double Action)
2. This cylinder is used only for locating and does not have a clamping function.

995
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Relative Equation of Expanding Force and Allowable Workpiece Weight for Locating Series

Pneumatic Series

F W
F Hydraulic Series
Horizontal Attitude μ Vertical Attitude
Seat Valve / Coupler
Hydraulic Unit
W
Manual Operation
Accessories
Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5
Workpiece Weight (W) ≦ Workpiece Weight (W) ≦ Expanding Force per Expansion Locating Pin (F)×Efficiency 0.5 Cautions / Others
Friction Coefficient of Workpiece Seat Face (μ)

Hole Clamp
SFA
SFC

Swing Clamp
LHA
LHC
LHS
LHW
LT/LG
TLA-2
TLB-2
TLA-1

Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1

Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
LLW

Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VFL
VFM
VFJ
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

996
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Hyd. Release model VFK2

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFK2000 clamping action without workpiece.

Straight Hole Taper Hole

Workpiece Hole Diameter


2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt Slope Angle

φ3
φWA
M5×0.8×12 R2 or less 2.5°or less

K+0.5 or more
K+0.5 or more
19

2 or less
Workpiece Hole Diameter
φWC

12 12

VFK Mounting Surface


CD
CB
CA
CC
CB

VFK-C
(Cut:One Direction Locating)
Notes:
※1. Set the O-ring to the mounting hole side (fixture side)
5 Seating Height:H15 before mounting the body.
※2. Do not use spring washer or toothed lock washer.
Datum Diameter 1. When mounting the product, use two mounting bolts
φL g8 VFK-C:Cut (Strength Grade 12.9) and tighten them evenly.
Steel Ball J φM Use two jack bolts to remove the product, keeping it

60° parallel to the mounting surface.


2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
K
E

3.5

G φN
C

◎ φ0.02 X
1

※2
H
B
F
A

φ15g7 -- 0.006
5

0.024
X
18.5

1-O-ring (Included)
AS568-013 (90° )

※1
1-O-ring (Included)
AS568-013 (90° )

5 Seating Height:H20 / H25

Datum Diameter
φL g8 VFK-C:Cut
Steel Ball J φM

60°
K
E

3.5

φN
C

◎ φ0.02 X
1

G
H

※2
B
A

φ15g7 -- 0.006
5

0.024
X
18.5

1-O-ring (Included)
AS568-013 (90° )

※1
1-O-ring (Included)
AS568-013 (90° )
997
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

2-M5×0.8 Thread Depth 9 or more Hydraulic Series


12 12
Valve / Coupler
Hydraulic Unit
★ ★
Manual Operation
Accessories
6.5

★ ★ Cautions / Others

※3
Air Blow Port 10.5 Hole Clamp
φ3 SFA
SFC

Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※3. Install the air blow port choosing one port from four ★ parts.
Z LHW
※4. There might be foam near the flange bottom depending on
Must be 1.3

LT/LG
※4
S
6.3S

roughness of mounting surface, but this is not a malfunction.


6.3

Mounting TLA-2
Surface
※5. Prepare the hydraulic lock port on the bottom within the range TLB-2
TLA-1
of φ12.1.
7.5

19 or more

※6. Prepare the hydraulic release port within   .


17±0.1

Link Clamp
※6

1. Make sure to check the cautions for cylinder mounting distance LK A


7

LK C
accuracy, workpiece hole distance accuracy and mounting phase
LK W
before installation. (Refer to P.1011.) LM/LJ
T MA - 2
※6 ※5
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※5
φ12.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFK2000-080-□-□ VFK2000-090-□-□ VFK2000-100-□-□ Compact Cylinder



3 Workpiece Hole Diam. Code 080 090 100 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT

Cylinder Stroke 1.8 2.2 2.6 Block Cylinder


A 41 46 51 41.5 46.5 51.5 42 47 52 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 Centering Vise


E 8.3 8 8 8.8 8.5 8.5 9.3 9 9 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 Control Valve

J 2.5 3 3.5 BZL


BZT
K 7.5 8 8.5
BZX/JZG
- 0.005 - 0.005 - 0.005
L 7.5 - 0.027 8.3 - 0.027 9.3 - 0.027
Pallet Clamp
M 5.5 6 6.5
VS
N 14.5 9 9 14.5 10 10 14.5 11 11 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VFJ
Weight g 70 80 90 70 80 90 70 80 100
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

998
Expansion Locating Pin Standard Locating Repeatability:10μm Hyd. Lock/Hyd. Release model VFK3

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFK3000 clamping action without workpiece.

Straight Hole Taper Hole

Workpiece Hole Diameter Slope Angle


2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt
φWA 2.5°or less
M5×0.8×12

φ3
R2 or less

K+0.5 or more
K+0.5 or more
7
23

2 or less
Workpiece Hole Diameter
φWC

14 14

CD
CB

VFK Mounting Surface


CA
CC
CB

VFK-C Notes:
(Cut:One Direction Locating) ※1. Set the O-ring to the mounting hole side (fixture side)
before mounting the body.
※2. Do not use spring washer or toothed lock washer.
Datum Diameter 1. When mounting the product, use two mounting bolts
φL g8 (Strength Grade 12.9) and tighten them evenly.
φM VFK-C:Cut Use two jack bolts to remove the product, keeping it

60° parallel to the mounting surface.


Steel Ball J
2. This product has no seat. Choose option -B:with Seating
Surface or prepare another seat if necessary.
K
E

1 3.5

φN
C

◎ φ0.02 X
G
H

※2
B
A

φ19g7 -- 0.028
0.007
5

X
18.5

1-O-ring (Included)
AS568-016 (90° )

※1
1-O-ring (Included)
AS568-016 (90° )

999
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

Pneumatic Series

14 14 2-M5×0.8 Thread Depth 9 or more Hydraulic Series

Valve / Coupler
★ Hydraulic Unit

★ Manual Operation
Accessories


7.5

★ Cautions / Others

※3 Hole Clamp
Air Blow Port 12.5
SFA
φ3
SFC

Swing Clamp
LHA
⊥ 0.01 Z LHC
Notes: LHS
φ19H7 +0.021
0 30°
Z ※3. Install the air blow port choosing one port from four ★ parts. LHW
Must be 1.3

※4. There might be foam near the flange bottom depending on LT/LG
※4
S
6.3S

6.3

Mounting TLA-2
Surface roughness of mounting surface, but this is not a malfunction.
TLB-2
※5. Prepare the hydraulic lock port on the bottom within the range TLA-1
7.5

of φ16.1.
19 or more
17±0.1

Link Clamp
※6. Prepare the hydraulic release port within   .
※6

LK A
1. Make sure to check the cautions for cylinder mounting distance
7

LK C
accuracy, workpiece hole distance accuracy and mounting phase LK W

before installation. (Refer to P.1011.) LM/LJ


T MA - 2
※6 ※5
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※5
φ16.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFK3000-110-□-□ VFK3000-120-□-□ VFK3000-130-□-□ VFK3000-140-□-□ VFK3000-150-□-□ Compact Cylinder



3 Workpiece Hole Diam. Code 110 120 130 140 150 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT

Cylinder Stroke 3 3 3.4 3.4 3.8 Block Cylinder


A 42.5 47.5 52.5 42.5 47.5 52.5 43 48 53 43 48 53 43.5 48.5 53.5 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve

J 4 4 4.5 4.5 5 BZL


BZT
K 9 9 9.5 9.5 10
BZX/JZG
- 0.006 - 0.006 - 0.006 - 0.006 - 0.006
L 10.2 - 0.033 11.2 - 0.033 12.0 - 0.033 13.0 - 0.033 13.8 - 0.033
Pallet Clamp
M 7.4 8.4 9.2 10.2 11.0
VS
N 18.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL

CD R4.5 R5 R5.3 R5.8 R6.1 VFM


VFJ
Weight g 100 120 130 100 120 130 100 120 140 110 120 140 110 120 140
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

1000
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK 2-B

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFK2000-BR clamping action without workpiece.
The ports of VFK2000-BL are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter


2-Mounting Bolt (Included) BA 2-M6×1 Thread for Jack Bolt Slope Angle

φ3
φWA
M5×0.8×12 R2 or less 2.5°or less

K+0.5 or more
K+0.5 or more
9.5

※2

2 or less
Workpiece Hole Diameter
φWC

45°
45°

BL

FC
O
W

. 24
BB

P.C.D

Seating Confirmation Air Hole


φ1.5

VFK Mounting Surface


CD
CB
CA
CC
CB

VFK-C
(Cut:One Direction Locating)
Notes:
※1. Set the O-ring to the mounting hole side (fixture side)
5 Seating Height:H15 before mounting the body.
※2. Please note that if the chamfer of the workpiece hole end is
Datum Diameter large, the seating confirmation air may not be increased.
φL g8 VFK-C:Cut 1. When mounting the product, use two mounting bolts
Steel Ball J φM (Strength Grade 12.9) and tighten them evenly.

60° Use two jack bolts to remove the product, keeping it


parallel to the mounting surface.
2. The port name is marked on the product surface.
K

3.5

(BLOW:Air Blow Port, FC:Seating Confirmation Air Port)


G φN
C

◎ φ0.02 X Continuously supply air pressure to the air blow port and
H±0.03

seating confirmation air port.


F
A

φ15g7 -- 0.006
5

0.024
X 1-O-ring (Included)
AS568-006 (90° )
18.5

1-O-ring (Included)
AS568-013 (90° )
※1
Port Position
1-O-ring (Included)
AS568-013 (90° ) R Seating Confirmation Air Hole L

5 Seating Height:H20 / H25

Datum Diameter
φL g8 VFK-C:Cut
Seating Confirmation Air Port
Steel Ball J φM

60° Air Blow Port

Note:
K

3. Please make sure that the port positions are correct.


3.5

φN
C

◎ φ0.02 X
G
H±0.03
A

φ15g7 -- 0.006
5

0.024
X 1-O-ring (Included)
AS568-006 (90° )
18.5

1-O-ring (Included)
AS568-013 (90° )
※1
1-O-ring (Included)
AS568-013 (90° )
1001
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
Hydraulic Unit
P.C.D 24
. 24 P .C.D.
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ15H7 +0.018
0 30° ※3. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3

LT/LG
※3
S
6.3S

Mounting ※4. Prepare the hydraulic lock port on the bottom within the range
6.3

TLA-2
Surface
of φ12.1. TLB-2

※5. Prepare the hydraulic release port within   . TLA-1


7.5

19 or more

1. Make sure to check the cautions for cylinder mounting distance


17±0.1

Link Clamp
※5

accuracy, workpiece hole distance accuracy and mounting phase LK A


7

LK C
before installation. (Refer to P.1011.)
LK W
LM/LJ
T MA - 2
※5 ※4
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※4
φ12.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFK2000-080-□-□-B□ VFK2000-090-□-□-B□ VFK2000-100-□-□-B□ Compact Cylinder



3 Workpiece Hole Diam. Code 080 090 100 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT

Cylinder Stroke 1.8 2.2 2.6 Block Cylinder


A 41 46 51 41.5 46.5 51.5 42 47 52 DBA

C 4 4 4 4 4 4 4 4 4 DBC

F 9 9 9.5 9 9 9.5 9 9 9.5 Centering Vise


G 8° 25° 40° 8° 25° 40° 8° 25° 40° FVA
H 15 20 25 15 20 25 15 20 25 FVD
FVC
J 2.5 3 3.5
K 7.5 8 8.5 Control Valve

L 7.5 - 0.005
8.3 - 0.005
9.3 - 0.005 BZL
- 0.027 - 0.027 - 0.027
BZT
M 5.5 6 6.5
BZX/JZG
N 15.5 15.5 15.5 16.5 16.5 16.5 17.5 17.5 17.5
Pallet Clamp
BA 12 13 14
VS
BB 6 6.5 7 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VFJ
Weight g 80 90 110 80 90 110 80 90 110
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

1002
Expansion Locating Pin with Seating Surface Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK 3-B

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFK3000-BR clamping action without workpiece.
The ports of VFK3000-BL are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter Slope Angle

φ
2-Mounting Bolt (Included) BA 2-M6×1 Thread for Jack Bolt 2.5°or less
37
φWA
M5×0.8×12 R2 or less

K+0.5 or more
K+0.5 or more
11.5

※2

2 or less
Workpiece Hole Diameter
φWC

45°
45°

BL

FC
O
W

. 28
P.C.D
BB

Seating Confirmation Air Hole


φ1.5

CD VFK Mounting Surface


CB
CA
CC
CB

VFK-C Notes:
(Cut:One Direction Locating) ※1. Set the O-ring to the mounting hole side (fixture side)
before mounting the body.
※2. Please note that if the chamfer of the workpiece hole end is
Datum Diameter large, the seating confirmation air may not be increased.
φL g8 1. When mounting the product, use two mounting bolts
φM VFK-C:Cut (Strength Grade 12.9) and tighten them evenly.

60° Use two jack bolts to remove the product, keeping it


Steel Ball J
parallel to the mounting surface.
2. The port name is marked on the product surface.
(BLOW:Air Blow Port, FC:Seating Confirmation Air Port)
K

Continuously supply air pressure to the air blow port and


3.5

φN seating confirmation air port.


◎ φ0.02 X
C

G
H±0.03
A

φ19g7 -- 0.028
0.007
5

X 1-O-ring (Included)
AS568-006 (90° )
18.5

1-O-ring (Included)
AS568-016 (90° )
Port Position
※1
1-O-ring (Included)
AS568-016 (90° )
R Seating Confirmation Air Hole L

Seating Confirmation Air Port

Air Blow Port

Note:
3. Please make sure that the port positions are correct.

1003
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Hydraulic Series
2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more
Valve / Coupler
P.C.D 8 Hydraulic Unit
.2
. 28 P.C.D
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
SFA
Air Blow Port Seating Confirmation Air Port Seating Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC
LHS
φ19H7 +0.021
0 30° ※3. There might be foam near the flange bottom depending on
Z LHW
roughness of mounting surface, but this is not a malfunction.
Must be 1.3

LT/LG
※3
S
6.3S

Mounting ※4. Prepare the hydraulic lock port on the bottom within the range
6.3

TLA-2
Surface
of φ16.1. TLB-2

※5. Prepare the hydraulic release port within   . TLA-1


7.5

19 or more
17±0.1

1. Make sure to check the cautions for cylinder mounting distance Link Clamp
※5

accuracy, workpiece hole distance accuracy and mounting phase LK A


7

LK C
before installation. (Refer to P.1011.)
LK W
LM/LJ
T MA - 2
※5 ※4
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※4
φ16.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFK3000-110-□-□-B□ VFK3000-120-□-□-B□ VFK3000-130-□-□-B□ VFK3000-140-□-□-B□ VFK3000-150-□-□-B□ Compact Cylinder



3 Workpiece Hole Diam. Code 110 120 130 140 150 LL
5 Seating Height
  H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT

Cylinder Stroke 3 3 3.4 3.4 3.8 Block Cylinder


A 42.5 47.5 52.5 42.5 47.5 52.5 43 48 53 43 48 53 43.5 48.5 53.5 DBA

C 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 DBC

F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 Centering Vise


G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° FVA
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 FVD
FVC
J 4 4 4.5 4.5 5
K 9 9 9.5 9.5 10 Control Valve

L 10.2 -- 0.006 11.2 -- 0.006 12.0 -- 0.006 13.0 -- 0.006 13.8 -- 0.006 BZL
0.033 0.033 0.033 0.033 0.033
BZT
M 7.4 8.4 9.2 10.2 11.0
BZX/JZG
N 19.5 19.5 19.5 20.5 20.5 20.5 21.5 21.5 21.5 22.5 22.5 22.5 23.5 23.5 23.5
Pallet Clamp
BA 15 16 17 17 18
VS
BB 8 8.5 9 9.5 10 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL

R5.3 R5.8 R6.1 VFM


CD R4.5 R5
VFJ
Weight g 110 130 150 110 130 150 110 130 150 110 130 150 120 130 150
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

1004
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Hyd. Release m od e l VFK 2-M

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFK2000-MR clamping action without workpiece.
The ports of VFK2000-ML are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter


2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt Slope Angle

φ3
φWA
M5×0.8×12 R2 or less 2.5°or less

K+0.5 or more
K+0.5 or more
T

35°
EX
9.5

2 or less
Workpiece Hole Diameter
φWC

45°
45°

R
BL

O
NS
O
W

SE
. 24
P.C.D

VFK Mounting Surface


CD
CB
CA
CC
CB

VFK-C
(Cut:One Direction Locating)
Notes:
※1. Set the O-ring to the mounting hole side (fixture side)
5 Seating Height:H15 before mounting the body.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 VFK-C:Cut Use two jack bolts to remove the product, keeping it
Steel Ball J φM parallel to the mounting surface.

60° 2. The port name is marked on the product surface.


(EXT:Air Vent Port, BLOW:Air Blow Port,
SENSOR:Release Confirmation Air Port)
K
E

3.5

Continuously supply air pressure to the air blow port and


G φN
release confirmation air port.
C

◎ φ0.02 X
1

3. This product has no seat. Choose option -B:with Seating


H
B

Surface or prepare another seat if necessary.


F
A

- 0.006
φ15g7
5

- 0.024
X
18.5

1-O-ring (Included)
AS568-013 (90° )

1-O-ring (Included)
※1 Port Position
AS568-013 (90° )
R Air Vent Port L

5 Seating Height:H20 / H25

Datum Diameter
φL g8 VFK-C:Cut
Release Confirmation Air Port
Steel Ball J φM

60° Air Blow Port

Note:
K

4. Please make sure that the port positions are correct.


E

3.5

φN
C

◎ φ0.02 X
1

G
H
B
A

φ15g7 -- 0.006
5

0.024
X
18.5

1-O-ring (Included)
AS568-013 (90° )

※1
1-O-ring (Included)
AS568-013 (90° )
1005
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Air Vent Port 2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more Air Vent Port Hydraulic Series
φ3 φ3
Valve / Coupler
Hydraulic Unit
P.C.D 24

35°
.C.D.

35°
. 24 P
Manual Operation
Accessories

Cautions / Others

45°

45°
45°

45°
Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC

※2. There might be foam near the flange bottom depending on LHS
φ15H7 +0.018
0 30°
Z roughness of mounting surface, but this is not a malfunction.
LHW
Must be 1.3

LT/LG
※2
※3. Prepare the hydraulic lock port on the bottom within the
S
6.3S

Mounting
6.3

TLA-2
Surface
range of φ12.1. TLB-2
※4. Prepare the hydraulic release port within   . TLA-1
7.5

19 or more

1. Make sure to check the cautions for cylinder mounting distance


17±0.1

Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase
※4

LK A
before installation. (Refer to P.1011.)
7

LK C
LK W
LM/LJ
T MA - 2
※4 ※3
Hydraulic Release Port Hydraulic Lock Port T MA - 1
※3
φ12.1±0.05 Work Support
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFK2000-080-□-□-M□ VFK2000-090-□-□-M□ VFK2000-100-□-□-M□ Compact Cylinder



3 Workpiece Hole Diam. Code 080 090 100 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 7.6 ∼ 8.5 8.5 ∼ 9.5 9.5 ∼ 10.8
Workpiece Hole Diameter DP
WC (Taper Hole) 8 ∼ 8.5 9 ∼ 9.5 10 ∼ 10.8 DR
At Releasing φ7.5 or less φ8.3 or less φ9.3 or less DS
Datum Diameter
At Full Stroke φ8.5 or more φ9.5 or more φ10.8 or more DT

Cylinder Stroke 1.8 2.2 2.6 Block Cylinder


A 41 46 51 41.5 46.5 51.5 42 47 52 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 Centering Vise


E 8.3 8 8 8.8 8.5 8.5 9.3 9 9 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 Control Valve

J 2.5 3 3.5 BZL


BZT
K 7.5 8 8.5
BZX/JZG
- 0.005 - 0.005 - 0.005
L 7.5 - 0.027 8.3 - 0.027 9.3 - 0.027
Pallet Clamp
M 5.5 6 6.5
VS
N 14.5 9 9 14.5 10 10 14.5 11 11 VT
CA 3.5 4 4.5
Expansion
CB 0.4 0.4 0.5 Locating Pin
CC 6.7 7.5 8.3 VFL
VFM
CD R3.35 R3.75 R4.15
VFJ
Weight g 80 90 110 80 90 110 80 90 110
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

1006
Expansion Locating Pin Release Confirmation Model Locating Repeatability:10μm Hyd. Lock/Hyd. Release model VFK3-M

External Dimensions Workpiece Hole Dimensions


※ This drawing shows VFK3000-MR clamping action without workpiece.
The ports of VFK3000-ML are placed to the symmetrical positions of
this drawing. Straight Hole Taper Hole

Workpiece Hole Diameter Slope Angle

φ
2-Mounting Bolt (Included) 2-M6×1 Thread for Jack Bolt 2.5°or less
37
φWA
M5×0.8×12
R2 or less

K+0.5 or more
K+0.5 or more
T
EX

35°
11.5

2 or less
Workpiece Hole Diameter
φWC

45°
45°

R
BL

O
NS
O
W

SE
. 28
P.C.D

CD VFK Mounting Surface


CB
CA
CC
CB

VFK-C Notes:
(Cut:One Direction Locating) ※1. Set the O-ring to the mounting hole side (fixture side)
before mounting the body.
1. When mounting the product, use two mounting bolts
Datum Diameter (Strength Grade 12.9) and tighten them evenly.
φL g8 Use two jack bolts to remove the product, keeping it
φM VFK-C:Cut parallel to the mounting surface.

60° 2. The port name is marked on the product surface.


Steel Ball J
(EXT:Air Vent Port, BLOW:Air Blow Port,
SENSOR:Release Confirmation Air Port)
Continuously supply air pressure to the air blow port and
K
E

release confirmation air port.


1 3.5

φN 3. This product has no seat. Choose option -B:with Seating


C

◎ φ0.02 X
G Surface or prepare another seat if necessary.
H
B
A

4
7.5

φ19g7 -- 0.007
0.028
X
21

1-O-ring (Included)
AS568-016 (90° )
Port Position
※1
1-O-ring (Included)
AS568-016 (90° )
R Air Vent Port L

Release Confirmation Air Port

Air Blow Port

Note:
4. Please make sure that the port positions are correct.

1007
Expansion Locating Pin Action Model No. Indication /Specifications External Dimensions Model No. Indication /Specifications External Dimensions Cautions
Index
Digest P.937 Description (VFJ) (VFJ) (VFK) (VFK) P.1009

High-Power
Machining Dimensions for Mounting Series

7 Port Position:R 7 Port Position:L Pneumatic Series

Air Vent Port Air Vent Port


2-M5×0.8 Thread Depth 9 or more 2-M5×0.8 Thread Depth 9 or more Hydraulic Series
φ3 φ3

Valve / Coupler
P.C.D Hydraulic Unit
28

35°
.C.D.

35°
. 28 P
Manual Operation
Accessories

Cautions / Others

45°

45°
45°
45°

Hole Clamp
SFA
Air Blow Port Release Confirmation Air Port Release Confirmation Air Port Air Blow Port SFC
φ3 φ3 φ3 φ3
Swing Clamp
LHA
⊥ 0.01 Z Notes: LHC

※2. There might be foam near the flange bottom depending on LHS
φ19H7 +0.021
0 30°
Z roughness of mounting surface, but this is not a malfunction.
LHW
Must be 1.3

LT/LG
※2
※3. Prepare the hydraulic lock port on the bottom within the
S
6.3S

Mounting
6.3

TLA-2
Surface
range of φ16.1. TLB-2
※4. Prepare the hydraulic release port within   . TLA-1
10

21.5 or more

1. Make sure to check the cautions for cylinder mounting distance


19.5±0.1

Link Clamp
accuracy, workpiece hole distance accuracy and mounting phase LK A
※4

before installation. (Refer to P.1011.) LK C


7

LK W
LM/LJ
T MA - 2
T MA - 1
※4 ※3
Hydraulic Release Port Hydraulic Lock Port
※3
Work Support
φ16.1±0.05
LD
LC
T NC
TC
Air Sensing
Lift Cylinder
External Dimensions and Machining Dimensions for Mounting (mm) LLW

Model No. VFK3000-110-□-□-M□ VFK3000-120-□-□-M□ VFK3000-130-□-□-M□ VFK3000-140-□-□-M□ VFK3000-150-□-□-M□ Compact Cylinder



3 Workpiece Hole Diam. Code 110 120 130 140 150 LL


5 Seating Height H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 H15 H20 H25 LLR
LLU
WA (Straight Hole) 10.4 ∼ 12 11.4 ∼ 13 12.2 ∼ 14.1 13.2 ∼ 15.1 14 ∼ 16.2
Workpiece Hole Diameter DP
WC (Taper Hole) 11 ∼ 12 12 ∼ 13 13 ∼ 14.1 14 ∼ 15.1 15 ∼ 16.2 DR
At Releasing φ10.2 or less φ11.2 or less φ12.0 or less φ13.0 or less φ13.8 or less DS
Datum Diameter
At Full Stroke φ12.0 or more φ13.0 or more φ14.1 or more φ15.1 or more φ16.2 or more DT

Cylinder Stroke 3 3 3.4 3.4 3.8 Block Cylinder


A 45 50 55 45 50 55 45.5 50.5 55.5 45.5 50.5 55.5 46 51 56 DBA

B 11 15.5 20.5 11 15.5 20.5 11 15.5 20.5 11 15 20 11 15 20 DBC

C 3.2 4 4 3.2 4 4 3.2 4 4 3.2 4.5 4.5 3.2 4.5 4.5 Centering Vise
E 9.8 9.5 9.5 9.8 9.5 9.5 10.3 10 10 10.3 10 10 10.8 10.5 10.5 FVA
F 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 9 9 9.5 FVD
FVC
G 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40° 8° 25° 40°
H 15 20 25 15 20 25 15 20 25 15 20 25 15 20 25 Control Valve

J 4 4 4.5 4.5 5 BZL


BZT
K 9 9 9.5 9.5 10
BZX/JZG
- 0.006 - 0.006 - 0.006 - 0.006 - 0.006
L 10.2 - 0.033 11.2 - 0.033 12.0 - 0.033 13.0 - 0.033 13.8 - 0.033
Pallet Clamp
M 7.4 8.4 9.2 10.2 11.0
VS
N 18.5 12 12 18.5 13 13 18.5 14 14 18.5 15 15 18.5 16 16 VT
CA 5 5 5.5 5.5 6
Expansion
CB 0.6 0.6 0.7 0.7 0.8 Locating Pin
CC 9 10 10.6 11.6 12.2 VFL

CD R4.5 R5 R5.3 R5.8 R6.1 VFM


VFJ
Weight g 120 140 160 120 140 160 120 140 160 120 140 160 120 140 160
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

1008
Expansion Locating Pin  Cautions m od e l VFL/VFM/VFJ/ V F K

Cautions

● Notes for Design  VFL / VFM / VFJ / VFK common

1)Check Specifications 6)Reference Surface towards Z-axis


● Please use each product according to the specifications. ● -B:with Seating Surface has seating on the flange surface, but
VFL locates with spring and releases with hydraulic pressure. Standard and -M:Release Confirmation models have no seating
VFM locates and releases with hydraulic pressure. (reference surface towards Z-axis). Please prepare a seat separately.
VFJ locates with hydraulic pressure and releases with spring.
VFK locates and releases with hydraulic pressure. -B:with Seating Surface

Surface towards Z-axis


2) Notes for Circuit Design
● Please read Circuit Reference to assist with proper hydraulic Workpiece
circuit design.
Carry out sufficient advance review as the wrong circuit design Z

may lead to product malfunctioning and damage.


Base Plate
3)Air Supply
Expansion Locating Pin
● Continuously supply air pressure to the air blow port.
If air supply is shut off during operation, contaminants
enter into the cylinder leading to malfunctions. Standard / -M:Release Confirmation Model
● Continuously supply air pressure to the seating confirmation
Surface towards Z-axis
air port for -B:with Seating Surface, and to the release
confirmation air port for -M:Release Confirmation model.
Work

Clearance
piece

4)Setting Up the Clamps Z


● The expansion locating pin is a positioning cylinder and has
Seating
no clamping mechanism. A clamp must be provided separately.
(Prepared by Customer) Base Plate

Expansion Locating Pin


5)Expansion Locating Pin Mounting Direction (Phase)
● The Cut (VF□-C) locates a workpiece in the direction of rotation,
based on the datum (VF□-D). VF□-C (Cut: for locating in one
direction) locates in one direction (Y-axis), so phasing is necessary. 7) Adjusting Height of Expansion Locating Pin
● Seating height can be selected from 15mm / 20mm / 25mm.
When mounting the product, make sure that expanding direction ● For slight adjustment of seating height and expanding part height,
of -C (Cut) is perpendicular to -D (Datum). install a spacer (3mm or less) under the flange.

lar
cu Expanding Direction
di
Seating Height

Spacer
en

Y
Perp

(Prepared by Customer)

X
max. 3

Mounting Distance Accuracy


-D (Datum) -C (Cut)
better than ±0.02

lar ● Install a spacer block under the flange if the height of expansion
cu Expanding Direction
di locating pin is not enough.
en

Y
Perp

Mounting Distance Accuracy Spacer Block


-D (Datum) -C (Cut)
better than ±0.02 (Prepared by Customer)

Expanding Direction

Expanding direction of standard model is the same as


the direction of mounting bolt. Contact us if needing
to change the expanding direction of C:Cut.

1009
Expansion Locating Pin
Cautions
Digest P.937

High-Power
Series

Pneumatic Series

8)When the workpiece is in vertical position. 9)Inclination in the Z-axis direction. Hydraulic Series

● When setting a workpiece, make sure it is in proper proximity and ● If a workpiece is tilted when loading/unloading, expanded part
Valve / Coupler
square to the expansion locating pins. of expansion locating pin and workpiece hole will get stuck and Hydraulic Unit
If it is locked out of position, the products may be damaged. the cylinder and workpiece will be damaged. Workpiece should be
Manual Operation
● As the workpiece may fall down during releasing, it is recommended loaded and unloaded with less than 4/100 5/100 (approx. 2 3°
) Accessories
to set up the latching mechanism to prevent it from falling down. of tilt between workpiece and expansion locating pin plane.
Cautions / Others
● When the workpiece is used in vertical position (hanging on the wall), ● If necessary, provide guide pins to keep the workpiece level during
the internal moving parts tend to wear out. Check the locating accuracy loading and unloading. Please prepare guide pin (rough guide) etc.
regularly, and if exceeding the allowable range, replace the product. Hole Clamp
SFA
Workpiece
SFC
Example of Latching Mechanism
Swing Clamp
LHA
LHC
LHS
LHW
Expansion Locating Pin LT/LG
TLA-2
TLB-2
TLA-1

Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
Guide Pin
T MA - 1
(Rough Guide)
Work Support
LD
10)Thickness around the Workpiece Hole
LC
● Thin wall around the workpiece hole could be deformed by T NC
expanding force, and locating accuracy would not fill the TC
Air Sensing
specification. Please conduct trial testing and adjust to proper Lift Cylinder
hydraulic pressure before use. LLW

Compact Cylinder
LL
LLR
LLU
Deformation

DP
DR
DS
DT

Block Cylinder
DBA
DBC

Centering Vise
FVA
FVD
FVC

Control Valve
BZL
BZT
BZX/JZG

Pallet Clamp
VS
VT

Expansion
Locating Pin
VF L
VF M
VF J
VF K

Pull Stud Clamp


FP
FQ
Customized
Spring Cylinder
DW A /DW B

1010
Expansion Locating Pin  Cautions m od e l VFL/VFM/VFJ/ V F K

Cautions

● Notes for Design  Regarding to VFL / VFM ● Notes for Design  Regarding to VFJ / VFK

1) Distance Accuracy of VFL / VFM 1)Distance Accuracy of VFJ / VFK


● Distance accuracy of the VFL / VFM's mounting hole should be ● Distance accuracy between VFJ / VFK mounting holes (-D/-C)
better than ±0.02mm. and between workpiece holes has to be machined
The distance accuracy of each workpiece hole should be within corresponding with the allowable offset (VFJ / VFK-C:Cut).
the allowable offset.
Please refer to the following list of JIS B 0613 Class 2.

 Allowable Offset (C : Cut) ≧ Datum Cylinder Distance Accuracy


+Workpiece Hole Distance Accuracy
(Listed in JIS B 0613)

[JIS B 0613 Excerpt] unit : mm


Center Distance Classification Center Distance Accuracy
Greater than or less class 2
50 80 ±0.023
80 120 ±0.027
120 180 ±0.032
180 250 ±0.036
250 315 ±0.041
315 400 ±0.045
400 500 ±0.049
500 630 ±0.055
630 800 ±0.063
800 1000 ±0.070

Workpiece Hole Distance ※1

Workpiece

Base Plate

Expansion Locating Pin Distance


better than ±0.02

1011
Expansion Locating Pin
Cautions
Digest P.937

High-Power
Series

Pneumatic Series
● Installation Notes

1)Usable Fluid 5)Appropriate Measures for the Air Vent Port Hydraulic Series

● Please use the appropriate fluid by referring to the Hydraulic ● For the air vent port of -M:Release Confirmation model,
Valve / Coupler
Fluid List (P.1237). consider the environment and avoid coolant or any contaminants. Hydraulic Unit
If coolant or contaminants enter in the product, it will not function
Manual Operation
2)Procedure before Piping properly. Accessories
● The pipeline, piping connector and fixture circuits should be
Cautions / Others
cleaned and flushed thoroughly.
The dust and cutting chips in the circuit may lead to fluid leakage
and malfunction. Hole Clamp
SFA
SFC
3)Applying Sealing Tape
Swing Clamp
● Wrap with tape 1 to 2 times following the screwing direction.
LHA
Wrapping in the wrong direction will cause leaks and malfunction. Examples LHC
● Pieces of the sealing tape can lead to oil leaks and malfunction. ① Prepare the manifold piping. LHS
LHW
● When piping, be careful that contaminant such as sealing tape Use the manifold piping and prepare the air vent port to
LT/LG
does not enter in products. the place without the influence of coolant or cutting chips. TLA-2
TLB-2

4)Mounting / Removing Expansion Locating Pin TLA-1

● Use all bolts with hex holes (Strength Grade 12.9) and tighten Link Clamp
LK A
them with a torque wrench as shown in the table below.
LK C
Tighten them evenly to prevent twisting or jamming. LK W
LM/LJ
Model No. Thread Size Tightening Torque (N・m)
T MA - 2
VFL2000 M5×0.8 6.3
T MA - 1
VFL3000 M5×0.8 6.3
Work Support
VFL4000 M6×1 10 ② Prepare the external piping.
VFL5000 M6×1 10 LD
If it is impossible to prepare manifold piping like the case ①,
LC
VFL6000 M8×1.25 25
move the air vent port by using external piping to the place T NC
VFM2000 M5×0.8 6.3
VFM3000 M5×0.8 6.3
without the influence of coolant or any contaminants. TC
Air Sensing
VFM4000 M6×1 10 Lift Cylinder
VFM5000 M6×1 10 LLW
VFM6000 M8×1.25 25
Compact Cylinder
VFJ2000 M5×0.8 6.3
LL
VFJ3000 M5×0.8 6.3
LLR
VFK2000 M5×0.8 6.3
LLU
VFK3000 M5×0.8 6.3
DP
DR
● Do not use spring washer or toothed lock washer. DS
DT
● There might be foam near the flange bottom depending on
roughness of mounting surface, but this is not a malfunction. 6)Installation of O-ring (Included) Block Cylinder
DBA
● When removing the product, use two jack bolts (two mounting bolt ● For VFL / VFM (VFM2000 / VFM3000 / VFM4000) / VFK,
DBC
holes) in order not to damage the installation tap. The below picture set the O-ring to the mounting hole side (fixture side)
Centering Vise
shows the case in which the parallel pin (hollow set) is set in the before mounting the body.
FVA
tapped hole so that the installation tap will not be damaged.
FVD
FVC

Jack Bolt Control Valve


BZL
BZT
Expansion Locating Pin BZX/JZG

Pallet Clamp
VS
VT

Installation Tap Make sure to set the O-ring first. Expansion


Locating Pin
Parallel Pin (Hollow Set) etc.
VF L
VF M
VF J
VF K

Pull Stud Clamp


FP
FQ
・Hydraulic Fluid List ・Notes on Hydraulic Cylinder Speed Control Circuit
※ Please refer to P.1237 for common cautions. Customized
・Notes on Handling ・Maintenance/Inspection ・Warranty Spring Cylinder
DW A /DW B

1012
Expansion Locating Pin  Cautions model VFL/V F M

Circuit Reference

● Notes on Hydraulic Cylinder Speed Control Circuit VFL (Standard) VFL-B (with Seating Surface) VFL-M (Release Confirmation Model)

Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance.

Circuit Reference

Expansion Locating Pin and Recommended Air Pressure


0.3 ∼ 0.4MPa
other actuators on Air Blow
Air
different circuits.
VFL-C VFL-D Filter 5μm
(Cut) (Datum)

※2
Release Hydraulic Pressure

※3
Single-Action Actuator Double-Action Actuator
VFL
※2
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Single Action Releases with Hydraulic Pressure Release Hydraulic Pressure
Pressure
※1
model VFL
Expansion Locating Pin and Recommended Air Pressure
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow
Air
the same circuit.
VFL-C VFL-D Filter 5μm
(Cut) (Datum)

Release Hydraulic Pressure

Single-Action Actuator Double-Action Actuator ※3


VFL
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Releases with Hydraulic Pressure ※1 Release Hydraulic Pressure
Pressure
※1

Expansion Locating Pin and Recommended Air Pressure


other actuators on Seating 0.2MPa
Air Confirmation
different circuits.
Sensor
※4
Recommended
Air Pressure
VFL-D-B 0.3 ∼ 0.4MPa
VFL-C-B (Datum) Air Blow
Single Action (Cut) Air
Filter 5μm
model VFL-B

with Seating Surface ※2


Release Hydraulic Pressure

※3
Single-Action Actuator Double-Action Actuator
VFL-B
※2
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Releases with Hydraulic Pressure Release Hydraulic Pressure Pressure
※1

Expansion Locating Pin and Recommended Air Pressure


other actuators on Release 0.2MPa
Air Confirmation
different circuits.
Sensor
※4
Recommended
Air Pressure
VFL-D-M 0.3 ∼ 0.4MPa
VFL-C-M (Datum) Air Blow
Single Action (Cut) Air
Filter 5μm
model VFL-M

Release Confirmation Model ※2


Release Hydraulic Pressure

※3
Single-Action Actuator Double-Action Actuator
VFL-M
※2
Locates with Spring Lock Hydraulic Pressure
Hydraulic
Releases with Hydraulic Pressure Release Hydraulic Pressure Pressure
※1

Notes:
※1. The procedure for lock operation should be "VFL (Expansion Locating Pin)" → "other actuators".
Otherwise there might be accuracy failure and/or damages on the product.
※2. Use the check valve (Recommended cracking pressure:0.04MPa or less) if there is back pressure in the tank port.
※3. Adjust the flow rate so that there is no surge pressure.
※4. Recommended Air Sensor:ISA□-G (SMC), GPS3 (CKD)
1. This circuit reference is one example. It should be prepared depending on the fixture structure.
1013
Expansion Locating Pin
Cautions
Digest P.937

High-Power
Series

Pneumatic Series
● Notes on Hydraulic Cylinder Speed Control Circuit VFM (Standard) VFM-B (with Seating Surface) VFM-M (Release Confirmation Model)
Hydraulic Series
Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit
Circuit Reference
Manual Operation
Accessories
Expansion Locating Pin and Recommended Air Pressure
0.3 ∼ 0.4MPa
other actuators on Air Blow Cautions / Others
Air
different circuits.
VFM-C VFM-D Filter 5μm
(Cut) (Datum)
Hole Clamp
Lock Hydraulic Pressure ※2 SFA
SFC
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator Swing Clamp
VFM LHA
Lock Hydraulic Pressure ※2
Locates and Releases Hydraulic LHC

Double Action with Hydraulic Pressure Release Hydraulic Pressure Pressure LHS

※1 LHW
model VFM LT/LG
Expansion Locating Pin and Recommended Air Pressure
TLA-2
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow TLB-2
Air
the same circuit. TLA-1
VFM-C VFM-D Filter 5μm
(Cut) (Datum) Link Clamp
LK A
Lock Hydraulic Pressure LK C
LK W
Release Hydraulic Pressure
LM/LJ
Single-Action Actuator Double-Action Actuator ※3
VFM T MA - 2

Locates and Releases Lock Hydraulic Pressure


Hydraulic
T MA - 1

with Hydraulic Pressure ※1 Release Hydraulic Pressure


Pressure Work Support
※1
LD
LC
Expansion Locating Pin and Recommended Air Pressure T NC
other actuators on Seating 0.2MPa
TC
Air Confirmation
different circuits. Air Sensing
Sensor
Lift Cylinder
※4 Recommended
Air Pressure LLW
VFM-D-B 0.3 ∼ 0.4MPa
VFM-C-B (Datum) Air Blow Compact Cylinder
Double Action (Cut) Air
LL
Filter 5μm LLR
model VFM-B
LLU
with Seating Surface Lock Hydraulic Pressure ※2 DP
DR
Release Hydraulic Pressure
※3 DS
Single-Action Actuator Double-Action Actuator DT
VFM-B
※2
Locates and Releases Lock Hydraulic Pressure
Hydraulic
Block Cylinder
DBA
with Hydraulic Pressure Release Hydraulic Pressure Pressure
DBC
※1

Expansion Locating Pin and Recommended Air Pressure


Centering Vise

other actuators on Release 0.2MPa FVA


Air Confirmation FVD
different circuits.
Sensor FVC
※4
Recommended
Control Valve
Air Pressure
VFM-D-M 0.3 ∼ 0.4MPa BZL
VFM-C-M (Datum) Air Blow
Double Action (Cut) Air BZT

Filter 5μm BZX/JZG


model VFM-M
Pallet Clamp
Release Confirmation Model Lock Hydraulic Pressure ※2 VS
VT
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator Expansion
VFM-M Locating Pin
※2 VF L
Locates and Releases Lock Hydraulic Pressure
Hydraulic
VF M
with Hydraulic Pressure Release Hydraulic Pressure Pressure
VFJ
※1
VFK
Notes:
Pull Stud Clamp
※1. The procedure for lock operation should be "VFM (Expansion Locating Pin)" → "other actuators".
FP
Otherwise there might be accuracy failure and/or damages on the product.
FQ
※2. Use the check valve (Recommended cracking pressure:0.04MPa or less) if there is back pressure in the tank port.
Customized
※3. Adjust the flow rate so that there is no surge pressure. Spring Cylinder
※4. Recommended Air Sensor:ISA□-G (SMC), GPS3 (CKD) DW A /DW B
1. This circuit reference is one example. It should be prepared depending on the fixture structure.
1014
Expansion Locating Pin  Cautions m od e l VFJ/ V F K

Circuit Reference

● Notes on Hydraulic Cylinder Speed Control Circuit VFJ (Standard) VFJ-B (with Seating Surface) VFJ-M (Release Confirmation Model)

Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance.

Circuit Reference

Expansion Locating Pin and Recommended Air Pressure


0.3 ∼ 0.4MPa
other actuators on Air Blow
Air
different circuits.
VFJ-C VFJ-D Filter 5μm
(Cut) (Datum)

Lock Hydraulic Pressure ※2

※3
Single-Action Actuator Double-Action Actuator
VFJ
※2
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Single Action Releases with Spring Release Hydraulic Pressure Pressure
※1
model VFJ
Expansion Locating Pin and Recommended Air Pressure
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow
Air
the same circuit.
VFJ-C VFJ-D Filter 5μm
(Cut) (Datum)

Lock Hydraulic Pressure


Single-Action Actuator Double-Action Actuator ※3
VFJ
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Releases with Spring Release Hydraulic Pressure Pressure
※1
※1

Expansion Locating Pin and Recommended Air Pressure


other actuators on Seating 0.2MPa
Air Confirmation
different circuits.
Sensor
※4
Recommended
Air Pressure
VFJ-D-B 0.3 ∼ 0.4MPa
VFJ-C-B (Datum) Air Blow
Single Action (Cut) Air
Filter 5μm
model VFJ-B

with Seating Surface Lock Hydraulic Pressure ※2

※3
Single-Action Actuator Double-Action Actuator
VFJ-B
※2
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Releases with Spring Release Hydraulic Pressure
Pressure

※1

Expansion Locating Pin and Recommended Air Pressure


other actuators on Release 0.2MPa
Air Confirmation
different circuits.
Sensor
※4
Recommended
Air Pressure
VFJ-D-M 0.3 ∼ 0.4MPa
VFJ-C-M (Datum) Air Blow
Single Action (Cut) Air
Filter 5μm
model VFJ-M

Release Confirmation Model Lock Hydraulic Pressure ※2

※3
Single-Action Actuator Double-Action Actuator
VFJ-M
※2
Locates with Hydraulic Pressure Lock Hydraulic Pressure
Hydraulic
Releases with Spring Release Hydraulic Pressure
Pressure

※1

Notes:
※1. The procedure for lock operation should be "VFJ (Expansion Locating Pin)" → "other actuators".
Otherwise there might be accuracy failure and/or damages on the product.
※2. Use the check valve (Recommended cracking pressure:0.04MPa or less) if there is back pressure in the tank port.
※3. Adjust the flow rate so that there is no surge pressure.
※4. Recommended Air Sensor:ISA□-G (SMC), GPS3 (CKD)
1. This circuit reference is one example. It should be prepared depending on the fixture structure.
1015
Expansion Locating Pin
Cautions
Digest P.937

High-Power
Series

Pneumatic Series
● Notes on Hydraulic Cylinder Speed Control Circuit VFK (Standard) VFK-B (with Seating Surface) VFK-M (Release Confirmation Model)
Hydraulic Series
Please pay attention to the cautions below. Design the circuit for controlling the action speed of cylinder.
! Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit
Circuit Reference
Manual Operation
Accessories
Expansion Locating Pin and Recommended Air Pressure
0.3 ∼ 0.4MPa
other actuators on Air Blow Cautions / Others
Air
different circuits.
VFK-C VFK-D Filter 5μm
(Cut) (Datum)
Hole Clamp
Lock Hydraulic Pressure ※2 SFA
SFC
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator Swing Clamp
VFK LHA
Lock Hydraulic Pressure ※2
Locates and Releases Hydraulic LHC

Double Action with Hydraulic Pressure Release Hydraulic Pressure Pressure LHS

※1 LHW
model VFK LT/LG
Expansion Locating Pin and Recommended Air Pressure
TLA-2
Standard other actuators on
0.3 ∼ 0.4MPa
Air Blow TLB-2
Air
the same circuit. TLA-1
VFK-C VFK-D Filter 5μm
(Cut) (Datum) Link Clamp
LK A
Lock Hydraulic Pressure LK C
LK W
Release Hydraulic Pressure LM/LJ
Single-Action Actuator Double-Action Actuator ※3
VFK T MA - 2

Locates and Releases Lock Hydraulic Pressure


Hydraulic
T MA - 1

with Hydraulic Pressure Pressure Work Support


※1 Release Hydraulic Pressure
※1
LD
LC
Expansion Locating Pin and Recommended Air Pressure T NC
other actuators on Seating 0.2MPa
TC
Air Confirmation
different circuits. Air Sensing
Sensor
Lift Cylinder
※4
Recommended
LLW
Air Pressure
VFK-D-B 0.3 ∼ 0.4MPa
VFK-C-B (Datum) Air Blow Compact Cylinder
Double Action (Cut) Air
LL
Filter 5μm LLR
model VFK-B
LLU
with Seating Surface Lock Hydraulic Pressure ※2 DP
DR
Release Hydraulic Pressure
※3 DS
Single-Action Actuator Double-Action Actuator DT
VFK-B
※2
Locates and Releases Lock Hydraulic Pressure
Hydraulic
Block Cylinder
Pressure DBA
with Hydraulic Pressure Release Hydraulic Pressure
DBC
※1

Expansion Locating Pin and Recommended Air Pressure


Centering Vise

other actuators on Release 0.2MPa FVA


Air Confirmation FVD
different circuits.
Sensor FVC
※4
Recommended
Control Valve
Air Pressure
VFK-D-M 0.3 ∼ 0.4MPa BZL
VFK-C-M (Datum) Air Blow
Double Action (Cut) Air BZT

Filter 5μm BZX/JZG


model VFK-M
Pallet Clamp
Release Confirmation Model Lock Hydraulic Pressure ※2 VS
VT
Release Hydraulic Pressure
※3
Single-Action Actuator Double-Action Actuator Expansion
VFK-M Locating Pin
※2 VFL
Locates and Releases Lock Hydraulic Pressure
Hydraulic
VFM
with Hydraulic Pressure Release Hydraulic Pressure
Pressure
VF J
※1
VF K
Notes:
Pull Stud Clamp
※1. The procedure for lock operation should be "VFK (Expansion Locating Pin)" → "other actuators".
FP
Otherwise there might be accuracy failure and/or damages on the product.
FQ
※2. Use the check valve (Recommended cracking pressure:0.04MPa or less) if there is back pressure in the tank port.
Customized
※3. Adjust the flow rate so that there is no surge pressure. Spring Cylinder
※4. Recommended Air Sensor:ISA□-G (SMC), GPS3 (CKD) DW A /DW B
1. This circuit reference is one example. It should be prepared depending on the fixture structure.
1016
Cautions

Cautions

● Installation Notes (For Hydraulic Series) ● Hydraulic Fluid List

1)Check the Usable Fluid ISO Viscosity Grade ISO-VG-32


● Please use the appropriate fluid by referring to the Hydraulic Fluid List. Maker Anti-Wear Hydraulic Oil Multi-Purpose Hydraulic Oil
Showa Shell Sekiyu Tellus S2 M 32 Morlina S2 B 32
2)Procedure before Piping Idemitsu Kosan Daphne Hydraulic Fluid 32 Daphne Super Multi Oil 32

● The pipeline, piping connector and fixture circuits should be cleaned JX Nippon Oil & Energy Super Hyrando 32 Super Mulpus DX 32
Cosmo Oil Cosmo Hydro AW32 Cosmo New Mighty Super 32
by thorough flushing.
ExxonMobil Mobil DTE 24 Mobil DTE 24 Light
● The dust and cutting chips in the circuit may lead to fluid leakage
Matsumura Oil Hydol AW-32
and malfunction.
Castrol Hyspin AWS 32
● There is no filter provided with Kosmek s product except for a part
Note As it may be difficult to purchase the products as shown in the table from
of valves which prevents foreign materials and contaminants from
overseas, please contact the respective manufacturer.
getting into the circuit.

3)Applying Sealing Tape


● Wrap with tape 1 to 2 times following the screw direction.
● Pieces of the sealing tape can lead to oil leakage and malfunction.
● In order to prevent a foreign substance from going into the product
during the piping work, it should be carefully cleaned before working.

4)Air Bleeding of the Hydraulic Circuit


● If the hydraulic circuit has excessive air, the action time may become
very long. If air enters the circuit after connecting the hydraulic port
or under the condition of no air in the oil tank, please perform
the following steps.

① Reduce hydraulic pressure to less than 2MPa.


② Loosen the cap nut of pipe fitting closest to the clamp by one full turn.
③ Wiggle the pipeline to loosen the outlet of pipe fitting.
Hydraulic fluid mixed with air comes out.

④ Tighten the cap nut after bleeding.


⑤ It is more effective to bleed air at the highest point inside the circuit
or at the end of the circuit.
(Set an air bleeding valve at the highest point inside the circuit.)

5)Checking Looseness and Retightening


● At the beginning of the machine installation, the bolt and nut may
be tightened lightly. Check the looseness and re-tighten as required.

1237
Installation Notes Notes on Hydraulic Cylinder
Hydraulic Fluid List Notes on Handling Maintenance/Inspection Warranty
(For Hydraulic Series) Speed Control Circuit

High-Power
Series

Pneumatic Series
● Notes on Hydraulic Cylinder Speed Control Unit

Please pay attention to the cautions below. Design the hydraulic circuit for controlling the action speed of hydraulic cylinder.

Hydraulic Series

Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit

● Flow Control Circuit for Single Acting Cylinder In the case of meter-out circuit, the hydraulic circuit should Manual Operation
For spring return single acting cylinders, restricting flow be designed with the following points. Accessories
during release can extremely slow down or disrupt release action. ① Single acting components should not be used in the same
Cautions / Others
The preferred method is to control the flow during the lock action flow control circuit as the double acting components.
using a valve that has free-flow in the release direction. The release action of the single acting cylinders may become
It is also preferred to provide a flow control valve at each actuator. erratic or very slow.
Cautions
Installation Notes
(For Hydraulic Series)
Hydraulic Fluid List

Notes on Hydraulic Cylinder


Speed Control Circuit
Notes on Handling

Maintenance/
Inspection
Accelerated clamping speed by excessive hydraulic flow to
Warranty
the cylinder may sustain damage. In this case add flow control to
regulate flow. (Please add flow control to release flow if the
lever weight is put on at the time of release action when using Refer to the following circuit when both the single acting Company Profile

cylinder and double acting cylinder are used together. Company Profile
swing clamps.)
○ Separate the control circuit. Our Products
Flow Control at the Release Side
History

Index
Search by
Alphabetical Order

W Sales Offices

● Flow Control Circuit for Double Acting Cylinder


Flow control circuit for double acting cylinder should have meter-out
circuits for both the lock and release sides. Meter-in control can ○ Reduce the influence of double acting cylinder control unit.
have adverse effect by presence of air in the system. However, due to the back pressure in tank line, single action
However, in the case of controlling LKE, TMA, TLA, both lock side cylinder is activated after double action cylinder works.
and release side should be meter-in circuit.
Refer to P.75 for speed adjustment of LKE.
For TMA and TLA, if meter-out circuit is used, abnormal high
pressure is created, which causes oil leakage and damage.
  
【Meter-out Circuit】(Except LKE/TMA/TLA)

  
② In the case of meter-out circuit, the inner circuit pressure may
increase during the cylinder action because of the fluid supply.
The increase of the inner circuit pressure can be prevented by
reducing the supplied fluid beforehand via the flow control valve.
Especially when using sequence valve or pressure switches for
clamping detection. If the back pressure is more than the set
pressure then the system will not work as it is designed to.

【Meter-in Circuit】(LKE/TMA/TLA must be controlled with meter-in.)

Sequence Valve

Flow Control Valve


(Any location is OK)

1238
Cautions

Cautions

● Notes on Handling ● Maintenance and Inspection

1)It should be handled by qualified personnel. 1)Removal of the Machine and Shut-off of Pressure Source
● The hydraulic machine and air compressor should be handled ● Before the machine is removed, make sure that the
and maintained by qualified personnel. above-mentioned safety measures are in place. Shut off the
2)Do not handle or remove the machine unless the safety protocols air of hydraulic source and make sure no pressure exists in
are ensured. the hydraulic and air circuit.
① The machine and equipment can only be inspected or prepared ● Make sure there is no abnormality in the bolts and respective
when it is confirmed that the preventive devices are in place. parts before restarting.
② Before the machine is removed, make sure that the above-mentioned
safety measures are in place. Shut off the air of hydraulic source 2)Regularly clean the area around the piston rod and plunger.
and make sure no pressure exists in the hydraulic and air circuit. ● If it is used when the surface is contaminated with dirt, it may
③ After stopping the machine, do not remove until the temperature lead to packing seal damage, malfunctioning, fluid leakage
cools down. and air leaks.
④ Make sure there is no abnormality in the bolts and respective parts
before restarting the machine or equipment.

3)Do not touch clamp (cylinder) while clamp (cylinder) is working.


Otherwise, your hands may be injured due to clinching.

3) Please clean out the reference surface regularly (taper reference


surface and seating surface) of locating machine. (VS/VT/VFL/
VFM/VFJ/VFK/WVS/VWM/VWK/VX/VXF)
4)Do not disassemble or modify. ● Location products, except VX/VXF model, can remove
● If the equipment is taken apart or modified, the warranty will be contaminants with cleaning functions.
voided even within the warranty period. When installing pallets makes sure there is no thick sludge like
substances on pallets.
● Continuous use with dirt on components will lead to locating
functions not work properly, leaking and malfunction.

4) If disconnecting by couplers on a regular basis, air bleeding


should be carried out daily to avoid air mixed in the circuit.

5)Regularly tighten nuts, bolts, pins, cylinders and pipe line to


ensure proper use.

6)Make sure the hydraulic fluid has not deteriorated.

7)Make sure there is smooth action and no abnormal noise.


● Especially when it is restarted after left unused for a long
period, make sure it can be operated correctly.

8)The products should be stored in the cool and dark place


without direct sunshine or moisture.

9)Please contact us for overhaul and repair.

1239
Installation Notes Notes on Hydraulic Cylinder
Hydraulic Fluid List Notes on Handling Maintenance/Inspection Warranty
(For Hydraulic Series) Speed Control Circuit

High-Power
Series

Pneumatic Series
● Warranty

1)Warranty Period Hydraulic Series

● The product warranty period is 18 months from shipment from


Valve / Coupler
our factory or 12 months from initial use, whichever is earlier. Hydraulic Unit

Manual Operation
2)Warranty Scope Accessories
● If the product is damaged or malfunctions during the warranty
Cautions / Others
period due to faulty design, materials or workmanship, we will
replace or repair the defective part at our expense.
Defects or failures caused by the following are not covered.
Cautions
Installation Notes
① If the stipulated maintenance and inspection are not carried out. (For Hydraulic Series)

② If the product is used while it is not suitable for use based on Hydraulic Fluid List

the operator s judgment, resulting in defect. Notes on Hydraulic Cylinder


Speed Control Circuit
③ If it is used or handled in inappropriate way by the operator.
Notes on Handling
(Including damage caused by the misconduct of the third party.) Maintenance/
④ If the defect is caused by reasons other than our responsibility. Inspection
Warranty
⑤ If repair or modifications are carried out by anyone other than Kosmek,
or without our approval and confirmation, it will void warranty.
Company Profile
⑥ Other caused by natural disasters or calamities not attributable to
Company Profile
our company.
Our Products
⑦ Parts or replacement expenses due to parts consumption and
History
deterioration.
(Such as rubber, plastic, seal material and some electric components.)
Index
Search by
Damages excluding from direct result of a product defect shall be Alphabetical Order

excluded from the warranty.


Sales Offices

1240
Company Profile

Sales Offices
Sales Offices across the World
Japan TEL. +81-78-991-5162 FAX. +81-78-991-8787
KOSMEK LTD. 1-5, 2-chome, Murotani, Nishi-ku, Kobe-city, Hyogo, Japan 651-2241
Overseas Sales
〒651-2241 兵庫県神戸市西区室谷2丁目1番5号

USA TEL. +1-630-620-7650 FAX. +1-630-620-9015


KOSMEK(USA)LTD. 650 Springer Drive, Lombard, IL 60148 USA

Mexico TEL. +52-442-161-2347


KOSMEK USA Mexico Office Blvd Jurica la Campana 1040, B Colonia Punta Juriquilla Queretaro, QRO 76230 Mexico

EUROPE TEL. +43-463-287587 FAX. +43-463-287587-20


KOSMEK EUROPE GmbH Schleppeplatz 2 9020 Klagenfurt am Wörthersee Austria

China TEL. +86-21-54253000 FAX. +86-21-54253709


KOSMEK(CHINA)LTD. Room601, RIVERSIDE PYRAMID No.55, Lane21, Pusan Rd, Pudong Shanghai 200125, China
考世美(上海)貿易有限公司 中国上海市浦东新区浦三路21弄55号银亿滨江中心601室 200125

India TEL. +91-9880561695


KOSMEK LTD - INDIA F 203, Level-2, First Floor, Prestige Center Point, Cunningham Road, Bangalore -560052 India

Thailand TEL. +66-2-300-5132 FAX. +66-2-300-5133


Thailand Representative Office 67 Soi 58, RAMA 9 Rd., Suanluang, Suanluang, Bangkok 10250, Thailand

Taiwan
(Taiwan Exclusive Distributor)
TEL. +886-2-82261860 FAX. +886-2-82261890
Full Life Trading Co., Ltd. 16F-4, No.2, Jian Ba Rd., Zhonghe District, New Taipei City Taiwan 23511
盈生貿易有限公司 台湾新北市中和區建八路2號 16F- 4(遠東世紀廣場)

Philippines
(Philippines Exclusive Distributor)
TEL. +63-2-310-7286 FAX. +63-2-310-7286
G.E.T. Inc, Phil. Victoria Wave Special Economic Zone Mt. Apo Building, Brgy. 186, North Caloocan City, Metro Manila, Philippines 1427

Indonesia
(Indonesia Exclusive Distributor)
TEL. +62-21-29628607 FAX. +62-21-29628608
PT. Yamata Machinery Delta Commercial Park I, Jl. Kenari Raya B-08, Desa Jayamukti, Kec. Cikarang Pusat Kab. Bekasi 17530 Indonesia

Sales Offices in Japan


Head Office TEL. 078-991-5162 FAX. 078-991-8787
Osaka Sales Office
Overseas Sales 〒651-2241 兵庫県神戸市西区室谷2丁目1番5号

TEL. 048-652-8839 FAX. 048-652-8828


Tokyo Sales Office
〒331-0815 埼玉県さいたま市北区大成町4丁目81番地

TEL. 0566-74-8778 FAX. 0566-74-8808


Nagoya Sales Office
〒446-0076 愛知県安城市美園町2丁目10番地1

TEL. 092-433-0424 FAX. 092-433-0426


Fukuoka Sales Office
〒812-0006 福岡県福岡市博多区上牟田1丁目8-10-101
Global Network

Overseas Affiliates and Sales Offices


Distributors

Europe
Canada
U.S.A.

Asia
Mexico

Brazil

Australia

Asia Detailed Map

Korea

Japan
China

Taiwan
India

Thailand Philippines

Malaysia
Singapore

Indonesia

● FOR FURTHER INFORMATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US. JQA-QMA10823
KOSMEK HEAD OFFICE
● SPECIFICATIONS IN THIS CATALOG ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Company Profile

Sales Offices
Sales Offices across the World
Japan TEL. +81-78-991-5162 FAX. +81-78-991-8787
KOSMEK LTD. 1-5, 2-chome, Murotani, Nishi-ku, Kobe-city, Hyogo, Japan 651-2241
Overseas Sales
〒651-2241 兵庫県神戸市西区室谷2丁目1番5号

USA TEL. +1-630-620-7650 FAX. +1-630-620-9015


KOSMEK(USA)LTD. 650 Springer Drive, Lombard, IL 60148 USA

Mexico TEL. +52-442-161-2347


KOSMEK USA Mexico Office Blvd Jurica la Campana 1040, B Colonia Punta Juriquilla Queretaro, QRO 76230 Mexico

EUROPE TEL. +43-463-287587 FAX. +43-463-287587-20


KOSMEK EUROPE GmbH Schleppeplatz 2 9020 Klagenfurt am Wörthersee Austria

China TEL. +86-21-54253000 FAX. +86-21-54253709


KOSMEK(CHINA)LTD. Room601, RIVERSIDE PYRAMID No.55, Lane21, Pusan Rd, Pudong Shanghai 200125, China
考世美(上海)貿易有限公司 中国上海市浦东新区浦三路21弄55号银亿滨江中心601室 200125

India TEL. +91-9880561695


KOSMEK LTD - INDIA F 203, Level-2, First Floor, Prestige Center Point, Cunningham Road, Bangalore -560052 India

Thailand TEL. +66-2-300-5132 FAX. +66-2-300-5133


Thailand Representative Office 67 Soi 58, RAMA 9 Rd., Suanluang, Suanluang, Bangkok 10250, Thailand

Taiwan
(Taiwan Exclusive Distributor)
TEL. +886-2-82261860 FAX. +886-2-82261890
Full Life Trading Co., Ltd. 16F-4, No.2, Jian Ba Rd., Zhonghe District, New Taipei City Taiwan 23511
盈生貿易有限公司 台湾新北市中和區建八路2號 16F- 4(遠東世紀廣場)

Philippines
(Philippines Exclusive Distributor)
TEL. +63-2-310-7286 FAX. +63-2-310-7286
G.E.T. Inc, Phil. Victoria Wave Special Economic Zone Mt. Apo Building, Brgy. 186, North Caloocan City, Metro Manila, Philippines 1427

Indonesia
(Indonesia Exclusive Distributor)
TEL. +62-21-29628607 FAX. +62-21-29628608
PT. Yamata Machinery Delta Commercial Park I, Jl. Kenari Raya B-08, Desa Jayamukti, Kec. Cikarang Pusat Kab. Bekasi 17530 Indonesia

Sales Offices in Japan


Head Office TEL. 078-991-5162 FAX. 078-991-8787
Osaka Sales Office
Overseas Sales 〒651-2241 兵庫県神戸市西区室谷2丁目1番5号

TEL. 048-652-8839 FAX. 048-652-8828


Tokyo Sales Office
〒331-0815 埼玉県さいたま市北区大成町4丁目81番地

TEL. 0566-74-8778 FAX. 0566-74-8808


Nagoya Sales Office
〒446-0076 愛知県安城市美園町2丁目10番地1

TEL. 092-433-0424 FAX. 092-433-0426


Fukuoka Sales Office
〒812-0006 福岡県福岡市博多区上牟田1丁目8-10-101
Global Network

Overseas Affiliates and Sales Offices


Distributors

Europe
Canada
U.S.A.

Asia
Mexico

Brazil

Australia

Asia Detailed Map

Korea

Japan
China

Taiwan
India

Thailand Philippines

Malaysia
Singapore

Indonesia

● FOR FURTHER INFORMATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US. JQA-QMA10823
KOSMEK HEAD OFFICE
● SPECIFICATIONS IN THIS CATALOG ARE SUBJECT TO CHANGE WITHOUT NOTICE.