You are on page 1of 60

AGENDA

Special Subcommittee of the Planning and Zoning Commission


Missouri American Water Company Data Collection Unit Implementation

City Hall Council Chambers - 16860 Main Street


Monday, April 30, 2018
5:30 p.m.

I. Roll Call Of Subcommittee Members (Commissioners Gragnani, Lee, Renner, And Chair
Bopp)

II. Review Of Tonight’s Agenda And Opening Remarks By Chair Bopp

III. Identification Of Issues And Presentation Of Materials For Discussion By Department Of


Planning

Documents:

III. COMMISSIONER LEE EMAIL.PDF


III. CALCULATION SUBMITTAL
PACKAGE_52_AGL_POLEMOUNT_REDUCED.PDF
III. CALCULATION SUBMITTAL PACKAGE_SIRENPOLE_REV_2016-09-
27_REDUCED.PDF
III. CALCULATION SUBMITTAL
PACKAGE_34_AGL_POLEMOUNT_REDUCED.PDF

IV. Discussion Among Subcommittee Members And Petitioner

V. Consensus On The Subcommittee’s Recommendation To The Planning And Zoning


Commission And Next Steps

VI. Closing Remarks And Adjournment

If you would like to submit a comment regarding an item on this meeting agenda,
please visit the Form Center.

Note:  The Special Subcommittee of the Planning and Zoning Commission will consider and act upon these 
matters listed above and any such others as may be presented at the meeting and determined appropriate
for discussion at that time.

The City of Wildwood will provide reasonable accommodations for persons attending Planning and
Note:  The Special Subcommittee of the Planning and Zoning Commission will consider and act upon these 
matters listed above and any such others as may be presented at the meeting and determined appropriate
for discussion at that time.

The City of Wildwood will provide reasonable accommodations for persons attending Planning and
Zoning Commission Special Subcommittee meetings.  Requests for reasonable accommodations should 
be made directly to Amanda Foster, City Clerk, at 636-458-0440, or email at
afoster@cityofwildwood.com, at least 48 hours prior to the start of the meeting.
TABLE OF CONTENTS

DESCRIPTION ................................................................................................................................... PAGE


COVER LETTER ....................................................................................................................................... 1

52’ AGL POLE MOUNT DRAWINGS .................................................................................................. 2-3

52’ AGL POLE MOUNT STRUCTURAL ANALYSIS ......................................................................... 4-5

USGS SITE SEISMIC PARAMETERS ................................................................................................ 6-10

HARDWARE SPEC’S ........................................................................................................................ 11-16


Dwayne Kiefer April 22, 2016
Program Manager
945 Hornet Drive
Hazelwood, MO 63042

Subject: Aclara DCU Deployment

Dear Dwayne:

I have reviewed the structural adequacy of the above referenced project and it is my determination that to the
best of my knowledge, information and belief, the design of these timber poles is in substantial compliance
with current building code requirements. A structural analysis of the proposed timber poles was conducted
based upon the provided information. This analysis was used to verify the section capacity of the poles.

The poles have been designed to meet a 90-mph, 3-second gust wind speed and also checked against a 1” radial
ice condition with a reduced wind speed of 40-mph, 3-second gust. This analysis was conducted with guidance
from the ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures & Antennas, ASCE/SEI
7, Minimum Design Loads for Buildings & Other Structures, and the International Building Code.

In order for the foundations to function properly the poles should be set in a minimum of 12” diameter augured
hole to the appropriate depth against undisturbed earth. Pole shall be set plumb in 2 directions 90 degrees apart.
Hand tamping of native soils with pneumatic or vibrating equipment is an acceptable method of compaction.
Backfill shall be adequately compacted around the circumference of the pole.

All work should be performed in accordance with NEC, OSHA, and local building code standards.

If you have any questions of require further information in regards to this subject, please feel free to
contact us anytime. Thank you for the opportunity to be of service.

Civil Design, Inc.

Adam D. Bohnhoff, P.E., S.E.


Structural Department Manager

104 North Second Street, Suite A | Effingham, IL 62401 | 217.342.2025

Page 1
1552 South 7th Street
St. Louis, MO 63104
314.863.5570

CIVIL DESIGN,INC.
WBE | DBE
Missouri State Certificate
of Authority #2002006804

Page 2
1552 South 7th Street
St. Louis, MO 63104
314.863.5570

CIVIL DESIGN,INC.
WBE | DBE
Missouri State Certificate
of Authority #2002006804

Page 3
Project: Aclara DCU Deployment   SHEET NO. OF

  DESIGNED DATE 4/20/16


Job #: R2046   CHECKED ADB DATE 4/20/16

60 Foot Wood Pole Analysis

General Data
Pole Class = 3
Pole Type = Douglas Fir or Southern Pine
Tip Height of Pole, H = 52 ft
Embedded Depth of Pole, Hembed = 8 ft
Structure Class = II  
Circumference of Pole at 6' from Butt, Cbutt = 42 in
Circumference of Pole at Tip, Ctip = 23 in
Allowable Pole Fiber Strength, Fp = 8000 psi

Design Loads
Basic Wind Speed, V = 90 mph
Basic Wind Speed, Vice = 40 mph (Ice conditions)
Topographic Category = 1
Exposure Category = B
Gust Effect Factor, GH = 1.1
Force Coefficient, CF = 1.2 (For round pole)
Velocity Pressure Coefficient, Kz = 1.10
Topographic Constant, Kzt = 0.95
Wind Direction Probability Factor, Kd = 1.00
Importance Factor, I = 1.00

Velocity Pressure without Ice, qz = 21.73 psf


Velocity Pressure with Ice, qz = 4.29 psf

Design Pressure, qz = 28.68 psf

Pole Effective Projected Area, EPA = 91.00 sq ft

Design Wind Force, Fwind = 2610 lb


Design Wind Overturning Moment, Mwind = 47981 lb-ft (At Base)

Ultimate Resisting Moment, Mult = 59460 lb-ft 0.807 Utilization ratio < 1.00…..okay

Page 4 P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Design Calculations_wood pole_60 foot
4/22/2016
Project: Aclara DCU Deployment   SHEET NO. OF

  DESIGNED DATE 4/20/16


Job #: R2046   CHECKED ADB DATE 4/20/16

60 Foot Wood Pole Analysis

Seismic Analysis
Occupancy Category I
Importance Factor 1.00
Seismic Design Category D
Site Class D
Ss 0.583 g  
S1 0.168 g
SDS 0.518 g
SD1 0.238 g

Design Loads
T 0.269 sec
R 1.5
Cs 0.3453
Weight 3848 lb
Base Shear, V 1328.7 lb ...this is less than wind therefore wind controls

Page 5 P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Design Calculations_wood pole_60 foot
4/22/2016
Page 6
Page 7
Page 8
Page 9
Page 10
ATTACHMENT 3
DCU with Solar Charging Unit
DCUs with solar charging units are capable of two- Solar Panel Specifications
way communication with MTUs over the STAR RF
Dimensions 31.3” H x 26.5” W x 2.0” D
Network and with the NCC via cellular, Wi-Fi™,
Ethernet, or fiber optic backhaul. Its battery Weight 18.3 pounds
power, and solar charging unit, make it ideal for Power output 65 watts max
locations where traditional power sources are not
available. Nominal voltage 12 volts

Features Battery Specifications


• Remote firmware and configuration management Dimensions 6.9" H x 6.5" W x 4.9" D
• Individually tuned bandpass filter Weight 23.3 lbs
• Battery can provide up to 14 days of operation without
Nominal voltage 12 volt
recharging
• Non-volatile memory provides storage for approximately Capacity 26 A-h
600,000 transmissions or 28 days of data
• DCU enclosure security is provided by a door tamper indicator DCU Specifications
and the use of a DCU passphrase
External Enclosure 316 Stainless steel, NEMA 3R
Models Dimensions 22" H x 14" W x 8.25" D

Cellular GSM / GPRS / HSPA+ / CDMA / 1xRTT Internal PCB Enclosure Polycarbonate, NEMA 4X
501-9975VERST1R1 Verizon® Total weight 55 pounds
501-9975ATTST1R1 AT&T®, Bell Canada, Rogers™
Nominal voltage 12 VDC
501-9975SPRST1R1 Sprint®
Power Consumption 5 Watts average
Ethernet
Approval FCC Part 90, IC RSS-119
501-9975ETHST1R1
Wi-Fi
Environmental
501-9975WIFST1R1
Operating temperature -40°C to +70°C
Fiber Optic
Storage temperature -40°C to +85°C
501-9975FIBST1R1
0% to 95% relative humidity (non-
Operating humidity
condensing)
Mounting Kits
Vibration Seismic zone 4
Pole Banding or Through-pole
Wind load* 90 MPH
Roof
Water Tower
* Wind load rating is for DCU, DCU installation kit, antenna, and solar panel
installed with Aclara approved installation kits and in accordance with Aclara
STAR Antenna Specifications installation instructions. Wind load rating is independent of structure.

Dimensions Two 38.4" antennas spaced 48" apart

Weight 10 lbs

Frequency 450 - 470 MHz

Aclara Technologies LLC


30400 Solon Road, Solon, OH 44139 Y20341-TSS
P: 800.892.9008 F: 440.528.7199 support@aclara.com Revision F
©2012-2014 Aclara. All rights reserved. STAR is a registered trademark of Aclara Technologies
LLC. All other trademarks are the property of their respective owners.

Page 11
ATTACHMENT 4

EM-A10007
5 dBi UHF Fixed Station Telemetry Antenna
450-470 MHz, w/Integrated Vertical Down-tilt
 Fixed Point Data/Telemetry Access Points operating in extreme
environments for TETRA, LMR, DMR and Private UHF Networks
 Compressed Aperture Design for reduced height & visibility
 Integrated Down-tilt for optimized CPE coverage
 Xenoy™ base with TPV over mold with Solid Brass Adapter
 Dual Seal construction resists environmental ingress
 Rugged one-piece SS radiator, Solid Brass Adapter with
Durable/Conductive Black Chrome finish

Electrical Specifications
Frequency Band 450-470 MHz
VSWR 2:1 max
Impedance 50Ω
Gain 5 dBi
Power Rating 50 W
Polarization Linear, Vertical
E-Plane 25 Degrees, Nominal
Vertical Down-tilt (wrt Horizon) 5 Degrees
(OEM Specifications Available)
H-Plane Omnidirectional

Mechanical Specifications
Overall Length 28.4 in. (722 mm)
Whip Material Finish 17-7 Series SS, Black Chrome
Base Material Xenoy™ w/TPV Over Mold Grip
Mounting Application ¾ in. Thru-Hole NMO Mount
Jumper Cable Assembly & Connector Sold Separately
Operating Temperature -40° to 85° C
Corrosion Salt Fog
Humidity 95%
Environmental Ingress IP66

Specifications subject to change without notification. Custom specifications available per OEM request.

Page 12
ATTACHMENT 6
DCU on Pole

Antenna Assembly

Solar Panel

DCU

Page 13
ATTACHMENT 7 Mounting
Stainless
Steel
Banding

Stainless
Steel
Structure
Solar
Panel

Stainless
Steel
Bracket
&
Banding
DCU
Page 14
ATTACHMENT 8
65W PHOTOVOLTAIC MODULE - 65J

65W Photovoltaic module


65J
This line of modules is the direct result of over three decades of
design, manufacturing and use. Attending to every detail in the
design and manufacture of our products, our process controls
and testing methods have optimized module life and electrical
energy production.

Ameresco Solar’s off-grid module line offers the following


features and benefits:

► Built to last
From mountaintops to off-shore platforms, on weather stations in
the bitter cold of Antarctica and on telephone signal repeaters in
the hot Australian outback, the technology has been proven in
the harshest environments.

► Accessible junction box for


off-grid connections
J-type junction box has accessible
terminals for easier module
interconnections in off-grid applications,
and it allows fitting cable glands for
various sections.
► Thick, durable scratch resistant
back sheet
The thick back sheet provides extra
insulation and increased resistance to
protect your module against rough
handling. The white polyester
material lasts longer and increases
► High reliability energy production.
Cell interconnections and diode
placement use well-established
industry practice and are field-proven to
provide excellent reliability.
► Quality and certifications
ISO 9001 factory certification ensures that our
manufacturing facilities use proven manufacturing and
quality control processes.

Certified to IEC 61215 and 61730

Certified to UL1703 and ULC1703


Certified for use in Class 1, Division 2 Hazardous locations

Conforms with European Directive 2006/95/EC


Photographs are intended to portray typical module
appearance, actual module appearance may vary.

Page 15
65W PHOTOVOLTAIC MODULE - 65J
20W Photovoltaic module

Electrical characteristics
STC 1000W/m2
(1) (2)
NOCT 800W/m2
Maximum power (Pmax) 65W 46.8W 796 [31.3]
Including screw heads
Voltage at Pmax (Vmpp) 17.6V 15.7V 790 [31.1]
Without screw heads
Current at Pmax (Impp) 3.69A 2.95A front view
Short circuit current (Isc) 3.99A 3.23A

1234567
Open circuit voltage (Voc) 21.7V 19.7V

674 [26.5]
Module efficiency 12.1%
Tolerance (Pmax) ±10%
Nominal voltage 12V
Efficiency reduction at 200W/m2 <5% reduction (efficiency 11.5%)
Limiting reverse current 3.99A
Temperature coefficient of Isc 0.105%/°C
Temperature coefficient of Voc -0.360%/°C side view
50 [2.0]
Temperature coefficient of (Pmax) -0.45%/°C 20 [0.8]
(3)
NOCT 47±2°C Including screw heads
305 [12.0] 225 [8.9]
Maximum series fuse rating 10A back view
Application class (according to IEC 61730:2007) Class A
Junction Box dimensions:
Maximum system voltage 600V (US) / 1000V (IEC) 163.50 x 112.50 x 37.50
2
1: Values at Standard Test Conditions (STC): 1000W/m irradiance, AM1.5 solar spectrum and 25ºC module [6.4 x 4.4 x 1.5]

639 [25.2]
temperature
2: Values at 800W/m2 irradiance, Nominal Operation Cell Temperature (NOCT) and AM1.5 solar spectrum
3: Nominal Operation Cell Temperature: Module operation temperature at 800W/m2 irradiance, 20ºC air
temperature, 1m/s wind speed
Ground hole
2 places
Mechanical characteristics
Solar cells 36 crystalline silicon cells in series
152.5 [6.0] 245 [9.7]
Front cover High transmission 3.2mm (1/8th in) glass Dimensions in mm [in].
Encapsulant EVA
Back cover White polyester
Frame Silver anodized aluminum
Temperature - dependence of performance
Junction box IP65 with 4 terminal screw connection block; accepts
Current (A)

4.0
PG 13.5, M20 13mm (½“)conduit, or cable fittings
accepting 6-12mm diameter cable. Terminals accept
3.0
2.5-10mm2 (8-14 AWG) wire
Dimensions 796 x 674 x 50mm / 31.3 x 26.5 x 1.97in
2.0
Weight 6.4kg /14lbs
All dimensional tolerances within ±1% unless otherwise stated. t = 0ºC
1.0 t = 25ºC
t = 50ºC
t = 75ºC
Warranty* 0
► Free from defects in materials and workmanship for 2 years 0
0 10 20 30
Voltage (V)
► 90% min. power output over 12 years
► Optional 25 years available
* Refer to limited warranty certificate for terms and conditions. Irradiance - dependence of performance
Current (A)

4.0

Certification
Certified according to the extended version of the IEC 61215 (ed.2), 3.0 1000W/m2

EN 61215:2005-08 (Crystalline silicon terrestrial photovoltaic modules -


800W/m2
Design qualification and type approval). 2.0
600W/m2

Certified according to IEC 61730-1 and IEC 61730-2 (ed.1), 1.0 400W/m2

EN 61730-1:2007-05 and EN 61730-2:2007-05. (Photovoltaic module safety


200W/m2
qualification, requirements for construction and testing). 0
0 5 10 15 20
Voltage (V)
Listed to UL 1703 & ULC ORD-C1703 Standard for Safety by Intertek ETL.
Class C Fire Rating.
For more information, call 855-43-SOLAR or
Approved by Intertek ETL according to FM 3611, Dec 2004, and according visit www.amerescosolar.com.
to CAN/CSA C22.2 No. 213-M1987, 1st Edition, Reaffirmed 2004, for use in
a Class I, Division 2, Group A, B, C, D Hazardous (Classified) Location. This publication summarises product warranty and specifications which are subject to change without notice.
© 2013 Ameresco, Inc. Ameresco and the Ameresco logo, the orb symbol and the tagline “Green. Clean. Sustainable.”
are registered in the U.S. Patent and Trademark Office. All rights reserved. PS-4857-01-0/13 04 00.0
Page 16
TABLE OF CONTENTS
DESCRIPTION ................................................................................................................................... PAGE
COVER LETTER ....................................................................................................................................... 1

50’ AGL POLE MOUNT DRAWINGS .................................................................................................. 2-3

50’ AGL POLE MOUNT STRUCTURAL ANALYSIS ......................................................................... 4-6

USGS SITE SEISMIC PARAMETERS ................................................................................................ 7-11

HARDWARE SPEC’S ........................................................................................................................ 12-19


Dwayne Kiefer June 6, 2016
Program Manager
945 Hornet Drive
Hazelwood, MO 63042

Subject: Aclara DCU Deployment

Dear Dwayne:

I have reviewed the structural adequacy of the above referenced project and it is my determination that to the
best of my knowledge, information and belief, the analysis of these early warning siren timber poles is in
substantial compliance with current building code requirements. A structural analysis of the existing early
warning siren timber poles was conducted based upon the provided information. This analysis was used to
verify the section capacity of the poles.

The poles have been analyzed using a 90-mph, 3-second gust wind speed and also checked against a 1” radial
ice condition with a reduced wind speed of 40-mph, 3-second gust. This analysis was conducted with guidance
from the ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures & Antennas, ASCE/SEI
7, Minimum Design Loads for Buildings & Other Structures, and the International Building Code.

All work should be performed in accordance with NEC, OSHA, and local building code standards.

If you have any questions of require further information in regards to this subject, please feel free to
contact us anytime. Thank you for the opportunity to be of service.

Civil Design, Inc.

Adam D. Bohnhoff, P.E., S.E.


Structural Department Manager

Page 1
1552 South 7th Street
St. Louis, MO 63104
314.863.5570

CIVIL DESIGN,INC.
WBE | DBE DRAWING REVISED:
Missouri State Certificate
of Authority #2002006804 9/27/2016
1552 South 7th Street
St. Louis, MO 63104
314.863.5570

CIVIL DESIGN,INC.
WBE | DBE DRAWING REVISED:
Missouri State Certificate
of Authority #2002006804 9/27/2016
Project: Aclara DCU Deployment   SHEET NO. 1 OF 3

  DESIGNED DATE
Job #: R2046   CHECKED ADB DATE 6/3/16

60 Foot Wood Pole Analysis

Design Assumptions

Item: Weight (lbs) Area (sq ft) Height (ft) Moment (lb-ft)
Exist. Siren 558 30.83 57 49,973
Prop. DCU Antenna + Cross Arm 53 2.24 50 3,181
Exist. Siren Solar Panel 25 3.89 35 3,871
Prop. DCU Solar Panel 18 5.00 50 7,110
Existing Siren Cabinet 240 17.18 20 9,770
Prop. DCU Cabinet 80 2.69 50 3,827
974 61.82

P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Siren Pole Mount\Design Calculations_ex 
wood pole_60 foot.xlsx 6/8/16

Page 4
Project: Aclara DCU Deployment   SHEET NO. 2 OF 3

  DESIGNED DATE
Job #: R2046   CHECKED ADB DATE 6/3/16

60 Foot Wood Pole Analysis

General Data
Pole Class = 1
Pole Type = Douglas Fir or Southern Pine
Tip Height of Pole, H = 50 ft
Embedded Depth of Pole, Hembed = 10 ft
Structure Class = II  
Circumference of Pole at 6' from Butt, Cbutt = 48 in
Circumference of Pole at Tip, Ctip = 27 in
Allowable Pole Fiber Strength, Fp = 8000 psi

Design Loads
Basic Wind Speed, V = 90 mph
Basic Wind Speed, Vice = 40 mph (Ice conditions)
Topographic Category = 1
Exposure Category = B
Gust Effect Factor, GH = 1.1
Force Coefficient, CF = 1.2 (For round pole)
Velocity Pressure Coefficient, Kz = 1.09
Topographic Constant, Kzt = 0.95
Wind Direction Probability Factor, Kd = 1.00
Importance Factor, I = 1.00

Velocity Pressure without Ice, qz = 21.55 psf


Velocity Pressure with Ice, qz = 4.26 psf

Design Pressure, qz = 28.44 psf


Equipment Effective Projected Area, EPAeq = 61.82 sq ft
Pole Effective Projected Area, EPA = 78.13 sq ft

Design Wind Force, Fwind = 2222 lb


Design Wind Overturning Moment, Mwind = 109796 lb-ft (At Base)

Ultimate Resisting Moment, Mult = 151821 lb-ft 0.72 Utilization ratio < 1.00…..okay

P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Siren Pole Mount\Design Calculations_ex 
wood pole_60 foot.xlsx 6/8/16

Page 5
Project: Aclara DCU Deployment   SHEET NO. 3 OF 3

  DESIGNED DATE
Job #: R2046   CHECKED ADB DATE 6/3/16

60 Foot Wood Pole Analysis

Seismic Analysis
Occupancy Category I
Importance Factor 1.00
Seismic Design Category D
Site Class D
Ss 0.583 g  
S1 0.168 g
SDS 0.518 g
SD1 0.238 g

Design Loads
T 0.269 sec
R 1.5
Cs 0.3453
Weight 4016 lb
Base Shear, V 1386.7 lb ...this is less than wind therefore wind controls

P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Siren Pole Mount\Design Calculations_ex 
wood pole_60 foot.xlsx 6/8/16

Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
ATTACHMENT 3
DCU with Solar Charging Unit
DCUs with solar charging units are capable of two- Solar Panel Specifications
way communication with MTUs over the STAR RF
Dimensions 31.3” H x 26.5” W x 2.0” D
Network and with the NCC via cellular, Wi-Fi™,
Ethernet, or fiber optic backhaul. Its battery Weight 18.3 pounds
power, and solar charging unit, make it ideal for Power output 65 watts max
locations where traditional power sources are not
available. Nominal voltage 12 volts

Features Battery Specifications


• Remote firmware and configuration management Dimensions 6.9" H x 6.5" W x 4.9" D
• Individually tuned bandpass filter Weight 23.3 lbs
• Battery can provide up to 14 days of operation without
Nominal voltage 12 volt
recharging
• Non-volatile memory provides storage for approximately Capacity 26 A-h
600,000 transmissions or 28 days of data
• DCU enclosure security is provided by a door tamper indicator DCU Specifications
and the use of a DCU passphrase
External Enclosure 316 Stainless steel, NEMA 3R
Models Dimensions 22" H x 14" W x 8.25" D

Cellular GSM / GPRS / HSPA+ / CDMA / 1xRTT Internal PCB Enclosure Polycarbonate, NEMA 4X
501-9975VERST1R1 Verizon® Total weight 55 pounds
501-9975ATTST1R1 AT&T®, Bell Canada, Rogers™
Nominal voltage 12 VDC
501-9975SPRST1R1 Sprint®
Power Consumption 5 Watts average
Ethernet
Approval FCC Part 90, IC RSS-119
501-9975ETHST1R1
Wi-Fi
Environmental
501-9975WIFST1R1
Operating temperature -40°C to +70°C
Fiber Optic
Storage temperature -40°C to +85°C
501-9975FIBST1R1
0% to 95% relative humidity (non-
Operating humidity
condensing)
Mounting Kits
Vibration Seismic zone 4
Pole Banding or Through-pole
Wind load* 90 MPH
Roof
Water Tower
* Wind load rating is for DCU, DCU installation kit, antenna, and solar panel
installed with Aclara approved installation kits and in accordance with Aclara
STAR Antenna Specifications installation instructions. Wind load rating is independent of structure.

Dimensions Two 38.4" antennas spaced 48" apart

Weight 10 lbs

Frequency 450 - 470 MHz

Aclara Technologies LLC


30400 Solon Road, Solon, OH 44139 Y20341-TSS
P: 800.892.9008 F: 440.528.7199 support@aclara.com Revision F
©2012-2014 Aclara. All rights reserved. STAR is a registered trademark of Aclara Technologies
LLC. All other trademarks are the property of their respective owners.

Page 12
ATTACHMENT 4

EM-A10007
5 dBi UHF Fixed Station Telemetry Antenna
450-470 MHz, w/Integrated Vertical Down-tilt
 Fixed Point Data/Telemetry Access Points operating in extreme
environments for TETRA, LMR, DMR and Private UHF Networks
 Compressed Aperture Design for reduced height & visibility
 Integrated Down-tilt for optimized CPE coverage
 Xenoy™ base with TPV over mold with Solid Brass Adapter
 Dual Seal construction resists environmental ingress
 Rugged one-piece SS radiator, Solid Brass Adapter with
Durable/Conductive Black Chrome finish

Electrical Specifications
Frequency Band 450-470 MHz
VSWR 2:1 max
Impedance 50Ω
Gain 5 dBi
Power Rating 50 W
Polarization Linear, Vertical
E-Plane 25 Degrees, Nominal
Vertical Down-tilt (wrt Horizon) 5 Degrees
(OEM Specifications Available)
H-Plane Omnidirectional

Mechanical Specifications
Overall Length 28.4 in. (722 mm)
Whip Material Finish 17-7 Series SS, Black Chrome
Base Material Xenoy™ w/TPV Over Mold Grip
Mounting Application ¾ in. Thru-Hole NMO Mount
Jumper Cable Assembly & Connector Sold Separately
Operating Temperature -40° to 85° C
Corrosion Salt Fog
Humidity 95%
Environmental Ingress IP66

Specifications subject to change without notification. Custom specifications available per OEM request.

Page 13
ATTACHMENT 6
DCU on Pole

Antenna Assembly

Solar Panel

DCU

Page 14
ATTACHMENT 7 Mounting
Stainless
Steel
Banding

Stainless
Steel
Structure
Solar
Panel

Stainless
Steel
Bracket
&
Banding
DCU
Page 15
ATTACHMENT 8
65W PHOTOVOLTAIC MODULE - 65J

65W Photovoltaic module


65J
This line of modules is the direct result of over three decades of
design, manufacturing and use. Attending to every detail in the
design and manufacture of our products, our process controls
and testing methods have optimized module life and electrical
energy production.

Ameresco Solar’s off-grid module line offers the following


features and benefits:

► Built to last
From mountaintops to off-shore platforms, on weather stations in
the bitter cold of Antarctica and on telephone signal repeaters in
the hot Australian outback, the technology has been proven in
the harshest environments.

► Accessible junction box for


off-grid connections
J-type junction box has accessible
terminals for easier module
interconnections in off-grid applications,
and it allows fitting cable glands for
various sections.
► Thick, durable scratch resistant
back sheet
The thick back sheet provides extra
insulation and increased resistance to
protect your module against rough
handling. The white polyester
material lasts longer and increases
► High reliability energy production.
Cell interconnections and diode
placement use well-established
industry practice and are field-proven to
provide excellent reliability.
► Quality and certifications
ISO 9001 factory certification ensures that our
manufacturing facilities use proven manufacturing and
quality control processes.

Certified to IEC 61215 and 61730

Certified to UL1703 and ULC1703


Certified for use in Class 1, Division 2 Hazardous locations

Conforms with European Directive 2006/95/EC


Photographs are intended to portray typical module
appearance, actual module appearance may vary.

Page 16
65W PHOTOVOLTAIC MODULE - 65J
20W Photovoltaic module

Electrical characteristics
(1)
STC 1000W/m2 (2)
NOCT 800W/m2
Maximum power (Pmax) 65W 46.8W 796 [31.3]
Including screw heads
Voltage at Pmax (Vmpp) 17.6V 15.7V 790 [31.1]
Without screw heads
Current at Pmax (Impp) 3.69A 2.95A front view

1234567
Short circuit current (Isc) 3.99A 3.23A
Open circuit voltage (Voc) 21.7V 19.7V

674 [26.5]
Module efficiency 12.1%
Tolerance (Pmax) ±10%
Nominal voltage 12V
Efficiency reduction at 200W/m2 <5% reduction (efficiency 11.5%)
Limiting reverse current 3.99A
Temperature coefficient of Isc 0.105%/°C
Temperature coefficient of Voc -0.360%/°C side view
50 [2.0]
Temperature coefficient of (Pmax) -0.45%/°C 20 [0.8]
(3) Including screw heads
NOCT 47±2°C 305 [12.0] 225 [8.9]
Maximum series fuse rating 10A back view
Application class (according to IEC 61730:2007) Class A
Junction Box dimensions:
Maximum system voltage 600V (US) / 1000V (IEC) 163.50 x 112.50 x 37.50

639 [25.2]
2
1: Values at Standard Test Conditions (STC): 1000W/m irradiance, AM1.5 solar spectrum and 25ºC module [6.4 x 4.4 x 1.5]
temperature
2: Values at 800W/m2 irradiance, Nominal Operation Cell Temperature (NOCT) and AM1.5 solar spectrum
3: Nominal Operation Cell Temperature: Module operation temperature at 800W/m2 irradiance, 20ºC air
temperature, 1m/s wind speed
Ground hole

Mechanical characteristics
2 places

Solar cells 36 crystalline silicon cells in series


152.5 [6.0] 245 [9.7]
Front cover High transmission 3.2mm (1/8th in) glass Dimensions in mm [in].
Encapsulant EVA
Back cover White polyester
Frame Silver anodized aluminum
Temperature - dependence of performance
Junction box IP65 with 4 terminal screw connection block; accepts
Current (A)

4.0
PG 13.5, M20 13mm (½“)conduit, or cable fittings
accepting 6-12mm diameter cable. Terminals accept
3.0
2.5-10mm2 (8-14 AWG) wire
Dimensions 796 x 674 x 50mm / 31.3 x 26.5 x 1.97in
2.0
Weight 6.4kg /14lbs
All dimensional tolerances within ±1% unless otherwise stated. t = 0ºC
1.0 t = 25ºC
t = 50ºC
t = 75ºC
Warranty* 0
► Free from defects in materials and workmanship for 2 years 0
0 10 20 30
Voltage (V)
► 90% min. power output over 12 years
► Optional 25 years available
* Refer to limited warranty certificate for terms and conditions. Irradiance - dependence of performance
Current (A)

4.0

Certification
Certified according to the extended version of the IEC 61215 (ed.2), 3.0 1000W/m2

EN 61215:2005-08 (Crystalline silicon terrestrial photovoltaic modules -


800W/m2
Design qualification and type approval). 2.0
600W/m2

Certified according to IEC 61730-1 and IEC 61730-2 (ed.1), 1.0 400W/m2

EN 61730-1:2007-05 and EN 61730-2:2007-05. (Photovoltaic module safety


200W/m2
qualification, requirements for construction and testing). 0
0 5 10 15 20
Voltage (V)
Listed to UL 1703 & ULC ORD-C1703 Standard for Safety by Intertek ETL.
Class C Fire Rating.
For more information, call 855-43-SOLAR or
Approved by Intertek ETL according to FM 3611, Dec 2004, and according visit www.amerescosolar.com.
to CAN/CSA C22.2 No. 213-M1987, 1st Edition, Reaffirmed 2004, for use in
This publication summarises product warranty and specifications which are subject to change without notice.
a Class I, Division 2, Group A, B, C, D Hazardous (Classified) Location. © 2013 Ameresco, Inc. Ameresco and the Ameresco logo, the orb symbol and the tagline “Green. Clean. Sustainable.”
Page 17 are registered in the U.S. Patent and Trademark Office. All rights reserved. PS-4857-01-0/13 04 00.0
WPS2910 Ten Cell

Mass Notification Warning Product


Whelen's Mass Notification Other features are dependent upon one or
WPS2900 Series omni- two-way controls. Whelen equipment can be
directional voice product interfaced with many different types of two-way
radio communications products and systems,
delivers clear, powerful from ACE, MOSCAD and FSK.
voice communication. The following is available as standard options.
BOLD BLUE indicates the Whelen Model:
SYSTEM FEATURES
■ WPS2910 – Ten omni-directional speaker ONE-WAY CONTROLS
cells assembled in a vertical column ■ AUXIN – Auxilliary board for contact closure
■ Three compartment (Type III) natural activation
finish aluminum or stainless steel cabinet ■ D2030LL – 10 digit DTMF Landline
■ Speaker cell includes ten high efficiency ■ D2030NV – 10 digit DTMF VHF High-Band
400 watt EZ-PULL™ speaker drivers Narrow-Band
■ 50’ cable included ■ D2030NU – 10 digit DTMF UHF Narrow-Band
■ Pole top mounting bracket included ■ WPSTT – Two-tone sequential option
■ Public address and pre-recorded voice (one-way radio package must be ordered
message capability from above options)
■ AC temperature compensated TWO-WAY CONTROLS
“tri-mode” 10 amp battery charger ■ AUXCS – Two-way contact closure activation
■ Local or remote controls available and status board
■ Battery powered ■ C2030LL – Two-way landline activation
■ Ten power amplifiers WPS2910 with ■ C2030NV – 10 digit DTMF VHF High-Band
■ Electronic controller optional VALERTR Narrow-Band
and Solar SBC280
■ Tone Generator ■ C2030NU – 10 digit DTMF UHF Narrow-Band
■ Timer
OPTIONS
■ Local control push-buttons
■ FSKXMOD – Converts one-way and two-way
■ Battery switch controls above to FSK format
■ RDVM1G – digital voice option, one hour ■ STATUS – Cabinet window LED status
of message recording time indicator
■ SI TEST ® ■ PGINT – Paging interface
■ SLIDEOUT ™ battery tray ■ INTRUWPS – Intrusion alarm
■ Lightning arrestor
■ Six standard warning tones – Wail, Whoop,
Alert, Attack, Hi-Lo, Airhorn

SYSTEM OPTIONS
■ Solar option – Two each 80 watt panels,
with brackets and solar regulator
■ Batteries – Four each Delco S2000 or
Interstate Workaholic 31-MHD Batteries.
Check Whelen’s web site, www.whelen.com,
for other recommended batteries
■ Microphone – for use at the cabinet (locally)
or at the control point (remotely)

ACTIVATION CONTROLS
Our VHF and UHF radio narrow-band control
packages feature Whelen protocol
COMM/STAT™ and include the following:
■ Radio
■ Radio interface
■ Tone squelch
■ 2-3 dB gain omni-directional antenna UL
®
with bracket
■ 35’ of RG58 antenna cable Type III
■ Polyphaser Electronic
■ SI TEST Cabinet

■ Low battery alarm (two-way only)

Page 18
WPS2910 Ten Cell

Specifications
Height Width Depth Weight
Component MASS NOTIFICATION PRODUCTS
Inches (CM) Inches (CM) Inches (CM) Lbs. (kg)
Whelen Engineering Company, Inc.
WPS2910 Speaker 132.9 (337.6) 33.4 (84.8) − 558 (253.1) 51 Winthrop Road
Chester, Connecticut 06412-0684
Electronics Cabinet 860-526-9504
74.5 (189.2) 33.2 (84.3) 12 (30.5) 240 (108.9)
Type III 800-637-4736
Fax: 860-526-4784
Pole Top Bracket 30.5 (77) 12.0 (30.5) x See Drawing 68 (30.9)
(Optional) (with top plate) 13.5 (34.3) www.whelen.com
33.4" iowsales@whelen.com
Batteries add 230 lbs. Pallets, boxes and skids add weight.
Check with Whelen if a freight quote is needed. Whelen Engineering Company, Inc.
reserves the right to upgrade its products with
Electrical design improvements without notification.
© 2015 Whelen Engineering Company, Inc.
■ Battery Charger Input: 120VAC, 60 Hz, 7A fuse (240 VAC 50/60 Hz available) Printed in the U.S.A.
■ Battery Charger Output: 28VDC, 10 A (nominal) 11693H-071015
■ Batteries: (4) 12V, 115AH lead calcium
■ Standby Current: 80mA, 24VDC
■ Operating Current: 221A, 24 VDC
■ Power Amplifier Output Power: Tone: 4000 watts, Voice: 5000 watts
HEIGHT
“Our Mass Notification Products
Environmental see chart

Speak for Themselves”™


■ Operating Temperature: -35°C to +60°C
■ Storage Temperature: -65°C to +125°C
■ Humidity, Non Condensing: 0 to 95%

Ordering Information 5/8"-9 THRU HEX HEAD


OR SQUARE HEAD BOLTS.
(7 PLACES)
BASIC SYSTEM INCLUDES THE FOLLOWING MOUNTING BRACKET (4)
ALUMINUM CABINET (3)
■ WPS2910 – Speaker assembly with 50’ cable & electronics cabinet with all
the standard components including voice boards for pre-recorded messages
12” 13.5”
OPTIONS 10” 11”
■ AUXIN (one-way) / AUXCS (two-way) – Auxiliary boards for contact closure
activation 1” Clearence
between top
■ D2030LL / D2030NV / D2030NU – One-way controls 1 POINT RACK, SPOOL of pole and
inside bottom
INSULATOR AND
■ C2030LL / C2030NV / C2030NU – Two-way controls SERVICE CLAMP FOR
of bracket
AC SUPPLY. *
■ WPSTT – Two-tone sequential
■ FSKXMOD – FSK format (4) 10' SECTIONS 18”
18” 30”
■ STATUS – Cabinet window LED status indicator OF 1" RIGID STEEL
CONDUIT. *
30”

■ PGINT – Paging interface DRIP LOOP


■ INTRUWPS – Intrusion alarm (two-way only) WEATHER HEAD FOR
7.5” 4.5”

■ MSGPROG – Custom pre-recorded messages SERVICE ENTRANCE. *

■ MSGPROGL – Whelen library messages 2 POLE, 30A, NEMA #3R


A/C DISCONNECT. *
■ WPSNCMIC – Microphone for public address use at the cabinet 50' (TYP)
■ WPSBATT – One pair of Whelen approved batteries Customer
■ RTM – Roof top mount Supplied Pole
9.5” Dia.
■ SBC280 – Solar option A) .75 DIA. CONDUIT
A.C. POWER INPUT
(+/- 0.5)
Pole Top Bracket
OPTIONAL LIGHTING ACCESSORIES B) .75 DIA. CONDUIT-
ANTENNA CABLE
■ VALERT* - VisuAlert ™ lighting accessory
C)1.00 DIA. CONDUIT-
■ L31H*F4 – L31 LED, 24VDC SPEAKER DRIVERS
AND SOLAR
■ ISB24* - 24VDC strobe A B C
FLEX CONDUIT *
4 AWG COPPER WIRE
■ SCWPS – Strobe/LED controller with mounting plate, hardware and CABINET GROUND. *
harnessing for ISB24 4 AWG COPPER WIRE
■ LCWPS – LED controller with mounting plate, hardware and SPEAKER, ANTENNA
GROUND. *
harnessing for L31
■ STCTRL – Strobe controller only GROUND WIRES TIED
TO GROUND RODS
■ LEDCTRL – LED controller only PER SPEC. OR CODE. 10'-12' (TYP)

* Specify color A=Amber, B=Blue, R=Red, C=White/Clear, G-Green


Acoustic Performance
POLE SETTING DEPTH CLASS 1 OR 2
PER LOCAL CODES UTILITY POLE. *
Wattage: 4000 watts
Estimated Range: 6,100 ft / 1859 m GROUND RODS * PER SPEC, OR
GROUNDING PER LOCAL CODES.
Weather, terrain and other structures may impact the range. Each siren within the system * CUSTOMER SUPPLIED

may have a decreased or increased range depending on conditions beyond our control.

ISO 9001 Registered QMS

Page 19
TABLE OF CONTENTS
DESCRIPTION ................................................................................................................................... PAGE
COVER LETTER ....................................................................................................................................... 1

34’ AGL POLE MOUNT DRAWINGS .................................................................................................. 2-3

34’ AGL POLE MOUNT STRUCTURAL ANALYSIS ......................................................................... 4-5

USGS SITE SEISMIC PARAMETERS ................................................................................................ 6-10

HARDWARE SPEC’S ........................................................................................................................ 11-16


Dwayne Kiefer May 17, 2016
Program Manager
945 Hornet Drive
Hazelwood, MO 63042

Subject: Aclara DCU Deployment

Dear Dwayne:

I have reviewed the structural adequacy of the above referenced project and it is my determination that to the
best of my knowledge, information and belief, the design of these timber poles is in substantial compliance
with current building code requirements. A structural analysis of the proposed timber poles was conducted
based upon the provided information. This analysis was used to verify the section capacity of the poles.

The poles have been designed to meet a 90-mph, 3-second gust wind speed and also checked against a 1” radial
ice condition with a reduced wind speed of 40-mph, 3-second gust. This analysis was conducted with guidance
from the ANSI/TIA-222-G Structural Standard for Antenna Supporting Structures & Antennas, ASCE/SEI
7, Minimum Design Loads for Buildings & Other Structures, and the International Building Code.

In order for the foundations to function properly the poles should be set in a minimum of 12” diameter augured
hole to the appropriate depth against undisturbed earth. Pole shall be set plumb in 2 directions 90 degrees apart.
Hand tamping of native soils with pneumatic or vibrating equipment is an acceptable method of compaction.
Backfill shall be adequately compacted around the circumference of the pole.

All work should be performed in accordance with NEC, OSHA, and local building code standards.

If you have any questions of require further information in regards to this subject, please feel free to
contact us anytime. Thank you for the opportunity to be of service.

Civil Design, Inc.

Adam D. Bohnhoff, P.E., S.E.


Structural Department Manager



104 North Second Street, Suite A | Effingham, IL 62401 | 217.342.2025 

Page 1
1552 South 7th Street
St. Louis, MO 63104
314.863.5570

CIVIL DESIGN,INC.
WBE | DBE
Missouri State Certificate
of Authority #2002006804

Page 2
1552 South 7th Street
St. Louis, MO 63104
314.863.5570

CIVIL DESIGN,INC.
WBE | DBE
Missouri State Certificate
of Authority #2002006804

Page 3
Project: Aclara DCU Deployment   SHEET NO. OF

  DESIGNED DATE 5/14/16


Job #: R2046   CHECKED ADB DATE 5/14/16

40 Foot Wood Pole Analysis

General Data
Pole Class = 3
Pole Type = Douglas Fir or Southern Pine
Tip Height of Pole, H = 34 ft
Embedded Depth of Pole, Hembed = 6 ft
Structure Class = II  
Circumference of Pole at 6' from Butt, Cbutt = 36 in
Circumference of Pole at Tip, Ctip = 23 in
Allowable Pole Fiber Strength, Fp = 8000 psi

Design Loads
Basic Wind Speed, V = 90 mph
Basic Wind Speed, Vice = 40 mph (Ice conditions)
Topographic Category = 1
Exposure Category = B
Gust Effect Factor, GH = 1.1
Force Coefficient, CF = 1.2 (For round pole)
Velocity Pressure Coefficient, Kz = 1.01
Topographic Constant, Kzt = 0.95
Wind Direction Probability Factor, Kd = 1.00
Importance Factor, I = 1.00

Velocity Pressure without Ice, qz = 19.87 psf


Velocity Pressure with Ice, qz = 3.92 psf

Design Pressure, qz = 26.22 psf

Pole Effective Projected Area, EPA = 51.00 sq ft


Equipment Effective Projected Area, EPAeq = 8.21 sq ft
Design Wind Force, Fwind = 1337 lb
Design Wind Overturning Moment, Mwind = 21081 lb-ft (At Base)

Ultimate Resisting Moment, Mult = 37444 lb-ft 0.56 Utilization ratio < 1.00…..okay

P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Design Calculations_wood pole_40 
Page 4 foot_REVISED.xlsx 5/17/16
Project: Aclara DCU Deployment   SHEET NO. OF

  DESIGNED DATE 4/20/16


Job #: R2046   CHECKED ADB DATE 4/20/16

40 Foot Wood Pole Analysis

Seismic Analysis
Occupancy Category I
Importance Factor 1.00
Seismic Design Category D
Site Class D
Ss 0.583 g  
S1 0.168 g
SDS 0.518 g
SD1 0.238 g

Design Loads
T 0.269 sec
R 1.5
Cs 0.3453
Weight 1946 lb
Base Shear, V 671.86 lb ...this is less than wind therefore wind controls

P:\Infrastructure+Analytics\2046 ‐ Aclara DCU Deployment\Structural\Design Calculations_wood pole_40 
Page 5 foot_REVISED.xlsx 5/17/16
Page 6
Page 7
Page 8
Page 9
Page 10
ATTACHMENT 3
DCU with Solar Charging Unit
DCUs with solar charging units are capable of two- Solar Panel Specifications
way communication with MTUs over the STAR RF
Dimensions 31.3” H x 26.5” W x 2.0” D
Network and with the NCC via cellular, Wi-Fi™,
Ethernet, or fiber optic backhaul. Its battery Weight 18.3 pounds
power, and solar charging unit, make it ideal for Power output 65 watts max
locations where traditional power sources are not
available. Nominal voltage 12 volts

Features Battery Specifications


• Remote firmware and configuration management Dimensions 6.9" H x 6.5" W x 4.9" D
• Individually tuned bandpass filter Weight 23.3 lbs
• Battery can provide up to 14 days of operation without
Nominal voltage 12 volt
recharging
• Non-volatile memory provides storage for approximately Capacity 26 A-h
600,000 transmissions or 28 days of data
• DCU enclosure security is provided by a door tamper indicator DCU Specifications
and the use of a DCU passphrase
External Enclosure 316 Stainless steel, NEMA 3R
Models Dimensions 22" H x 14" W x 8.25" D

Cellular GSM / GPRS / HSPA+ / CDMA / 1xRTT Internal PCB Enclosure Polycarbonate, NEMA 4X
501-9975VERST1R1 Verizon® Total weight 55 pounds
501-9975ATTST1R1 AT&T®, Bell Canada, Rogers™
Nominal voltage 12 VDC
501-9975SPRST1R1 Sprint®
Power Consumption 5 Watts average
Ethernet
Approval FCC Part 90, IC RSS-119
501-9975ETHST1R1
Wi-Fi
Environmental
501-9975WIFST1R1
Operating temperature -40°C to +70°C
Fiber Optic
Storage temperature -40°C to +85°C
501-9975FIBST1R1
0% to 95% relative humidity (non-
Operating humidity
condensing)
Mounting Kits
Vibration Seismic zone 4
Pole Banding or Through-pole
Wind load* 90 MPH
Roof
Water Tower
* Wind load rating is for DCU, DCU installation kit, antenna, and solar panel
installed with Aclara approved installation kits and in accordance with Aclara
STAR Antenna Specifications installation instructions. Wind load rating is independent of structure.

Dimensions Two 38.4" antennas spaced 48" apart

Weight 10 lbs

Frequency 450 - 470 MHz

Aclara Technologies LLC


30400 Solon Road, Solon, OH 44139 Y20341-TSS
P: 800.892.9008 F: 440.528.7199 support@aclara.com Revision F
©2012-2014 Aclara. All rights reserved. STAR is a registered trademark of Aclara Technologies
LLC. All other trademarks are the property of their respective owners.

Page 11
ATTACHMENT 4

EM-A10007
5 dBi UHF Fixed Station Telemetry Antenna
450-470 MHz, w/Integrated Vertical Down-tilt
 Fixed Point Data/Telemetry Access Points operating in extreme
environments for TETRA, LMR, DMR and Private UHF Networks
 Compressed Aperture Design for reduced height & visibility
 Integrated Down-tilt for optimized CPE coverage
 Xenoy™ base with TPV over mold with Solid Brass Adapter
 Dual Seal construction resists environmental ingress
 Rugged one-piece SS radiator, Solid Brass Adapter with
Durable/Conductive Black Chrome finish

Electrical Specifications
Frequency Band 450-470 MHz
VSWR 2:1 max
Impedance 50Ω
Gain 5 dBi
Power Rating 50 W
Polarization Linear, Vertical
E-Plane 25 Degrees, Nominal
Vertical Down-tilt (wrt Horizon) 5 Degrees
(OEM Specifications Available)
H-Plane Omnidirectional

Mechanical Specifications
Overall Length 28.4 in. (722 mm)
Whip Material Finish 17-7 Series SS, Black Chrome
Base Material Xenoy™ w/TPV Over Mold Grip
Mounting Application ¾ in. Thru-Hole NMO Mount
Jumper Cable Assembly & Connector Sold Separately
Operating Temperature -40° to 85° C
Corrosion Salt Fog
Humidity 95%
Environmental Ingress IP66

Specifications subject to change without notification. Custom specifications available per OEM request.

Page 12
ATTACHMENT 6
DCU on Pole

Antenna Assembly

Solar Panel

DCU

Page 13
ATTACHMENT 7 Mounting
Stainless
Steel
Banding

Stainless
Steel
Structure
Solar
Panel

Stainless
Steel
Bracket
&
Banding
DCU
Page 14
ATTACHMENT 8
65W PHOTOVOLTAIC MODULE - 65J

65W Photovoltaic module


65J
This line of modules is the direct result of over three decades of
design, manufacturing and use. Attending to every detail in the
design and manufacture of our products, our process controls
and testing methods have optimized module life and electrical
energy production.

Ameresco Solar’s off-grid module line offers the following


features and benefits:

► Built to last
From mountaintops to off-shore platforms, on weather stations in
the bitter cold of Antarctica and on telephone signal repeaters in
the hot Australian outback, the technology has been proven in
the harshest environments.

► Accessible junction box for


off-grid connections
J-type junction box has accessible
terminals for easier module
interconnections in off-grid applications,
and it allows fitting cable glands for
various sections.
► Thick, durable scratch resistant
back sheet
The thick back sheet provides extra
insulation and increased resistance to
protect your module against rough
handling. The white polyester
material lasts longer and increases
► High reliability energy production.
Cell interconnections and diode
placement use well-established
industry practice and are field-proven to
provide excellent reliability.
► Quality and certifications
ISO 9001 factory certification ensures that our
manufacturing facilities use proven manufacturing and
quality control processes.

Certified to IEC 61215 and 61730

Certified to UL1703 and ULC1703


Certified for use in Class 1, Division 2 Hazardous locations

Conforms with European Directive 2006/95/EC


Photographs are intended to portray typical module
appearance, actual module appearance may vary.

Page 15
65W PHOTOVOLTAIC MODULE - 65J
20W Photovoltaic module

Electrical characteristics
STC 1000W/m2
(1) (2)
NOCT 800W/m2
Maximum power (Pmax) 65W 46.8W 796 [31.3]
Including screw heads
Voltage at Pmax (Vmpp) 17.6V 15.7V 790 [31.1]
Without screw heads
Current at Pmax (Impp) 3.69A 2.95A front view
Short circuit current (Isc) 3.99A 3.23A

1234567
Open circuit voltage (Voc) 21.7V 19.7V

674 [26.5]
Module efficiency 12.1%
Tolerance (Pmax) ±10%
Nominal voltage 12V
Efficiency reduction at 200W/m2 <5% reduction (efficiency 11.5%)
Limiting reverse current 3.99A
Temperature coefficient of Isc 0.105%/°C
Temperature coefficient of Voc -0.360%/°C side view
50 [2.0]
Temperature coefficient of (Pmax) -0.45%/°C 20 [0.8]
(3)
NOCT 47±2°C Including screw heads
305 [12.0] 225 [8.9]
Maximum series fuse rating 10A back view
Application class (according to IEC 61730:2007) Class A
Junction Box dimensions:
Maximum system voltage 600V (US) / 1000V (IEC) 163.50 x 112.50 x 37.50
2
1: Values at Standard Test Conditions (STC): 1000W/m irradiance, AM1.5 solar spectrum and 25ºC module [6.4 x 4.4 x 1.5]

639 [25.2]
temperature
2: Values at 800W/m2 irradiance, Nominal Operation Cell Temperature (NOCT) and AM1.5 solar spectrum
3: Nominal Operation Cell Temperature: Module operation temperature at 800W/m2 irradiance, 20ºC air
temperature, 1m/s wind speed
Ground hole
2 places
Mechanical characteristics
Solar cells 36 crystalline silicon cells in series
152.5 [6.0] 245 [9.7]
Front cover High transmission 3.2mm (1/8th in) glass Dimensions in mm [in].
Encapsulant EVA
Back cover White polyester
Frame Silver anodized aluminum
Temperature - dependence of performance
Junction box IP65 with 4 terminal screw connection block; accepts
Current (A)

4.0
PG 13.5, M20 13mm (½“)conduit, or cable fittings
accepting 6-12mm diameter cable. Terminals accept
3.0
2.5-10mm2 (8-14 AWG) wire
Dimensions 796 x 674 x 50mm / 31.3 x 26.5 x 1.97in
2.0
Weight 6.4kg /14lbs
All dimensional tolerances within ±1% unless otherwise stated. t = 0ºC
1.0 t = 25ºC
t = 50ºC
t = 75ºC
Warranty* 0
► Free from defects in materials and workmanship for 2 years 0
0 10 20 30
Voltage (V)
► 90% min. power output over 12 years
► Optional 25 years available
* Refer to limited warranty certificate for terms and conditions. Irradiance - dependence of performance
Current (A)

4.0

Certification
Certified according to the extended version of the IEC 61215 (ed.2), 3.0 1000W/m2

EN 61215:2005-08 (Crystalline silicon terrestrial photovoltaic modules -


800W/m2
Design qualification and type approval). 2.0
600W/m2

Certified according to IEC 61730-1 and IEC 61730-2 (ed.1), 1.0 400W/m2

EN 61730-1:2007-05 and EN 61730-2:2007-05. (Photovoltaic module safety


200W/m2
qualification, requirements for construction and testing). 0
0 5 10 15 20
Voltage (V)
Listed to UL 1703 & ULC ORD-C1703 Standard for Safety by Intertek ETL.
Class C Fire Rating.
For more information, call 855-43-SOLAR or
Approved by Intertek ETL according to FM 3611, Dec 2004, and according visit www.amerescosolar.com.
to CAN/CSA C22.2 No. 213-M1987, 1st Edition, Reaffirmed 2004, for use in
a Class I, Division 2, Group A, B, C, D Hazardous (Classified) Location. This publication summarises product warranty and specifications which are subject to change without notice.
© 2013 Ameresco, Inc. Ameresco and the Ameresco logo, the orb symbol and the tagline “Green. Clean. Sustainable.”
are registered in the U.S. Patent and Trademark Office. All rights reserved. PS-4857-01-0/13 04 00.0
Page 16

You might also like