Professional Documents
Culture Documents
EC 10003 12 Vol1 A Series PDF
EC 10003 12 Vol1 A Series PDF
A37 A1637
A56
A16 A10
A10
21
A16
A22 16
A37 21
A45 16
★1
Single Pumps A56 21 28
A Series Variable Displacement Piston Pumps
M
O A70
28
A90
A100 21
A145 28
A220 16
Double Pumps
O
28
★2 112
A70 A220
Inboard Pump A16 A37 A56 A145
A90
★1 Various control types are available such as pressure compensator type. Refer to page 29 and 30.
★2 The maximum operating pressure for each double pump depends on its combination of pumps. Contact us for details.
Instructions
Mounting Drain Piping
When installing the pump the filling port should be Install drain piping according to the chart and ensure that
positioned upwards. pressure within the pump housing should be maintained at
a normal pressure of less than 0.1 MPa and surge pressure
Alignment of Shaft of less than 0.5 MPa.
Employ a flexible coupling whenever possible, and avoid Length of piping should be less than 1 m, and the pipe end
any stress from bending or thrust. should be submerged in oil.
Maximum permissible misalignment is less than 0.1 mm
TIR and maximum permissible misangular is less than [Recommended Drain Piping Size]
0.2°.
Model Fitting Size Inside Dia. of Pipe
Suction Pressure
Permissible suction pressure at inlet port of the pump is 3/8
A10, A16, A22 10 mm or more
between -16.7 and +50 kPa. [Inside Dia. 8.5 mm or more]
For piping to the suction port, use the pipes of the same 1/2
diametre as that of the specified pipe flange to be used. A37, A45 12 mm or more
[Inside Dia. 12 mm or more]
Make sure that the height of the pump suction port is within
A56, A70, A90, 3/4
one metre from the oil level in the reservoir. 19 mm or more
A100, A145 [Inside Dia. 16 mm or more]
Hints on Piping
When using steel pipes for the suction or discharge ports, Bleeding Air
excessive load from the piping to the pump generates It may be necessary to bleed air from pump case and
excessive noise. outlet line to remove causes of vibration. An air bleed
Whenever there is fear of excessive load, please use rubber valve (Model Number ST1004-*-10*, Page 265) is
hoses. recommended for this purpose.
Suction Piping
In case the pump is installed above the oil level, the
suction piping and suction line filter should be located
lower than the pump position to prevent air in the suction
line.
When using steel pipes for the suction or discharge ports,
excessive load from the piping to the pump generates
excessive noise.
Whenever there is fear of excessive load, please use
rubber hoses.
A Series
the control valves so that the discharged oil from the system requirements.
pump is returned direct to the reservoir or the actuator
moves in a free load. Adjustment of Discharge Pressure
Turning the adjustment screw clockwise, increases
[Volume of Pre-fill Oil Required] pressure.
Model Volume cm3 Volume adjusted by each full turn of the pressure
A10 370 adjustment screw
A16/A22 600
Adjustment Volume
A37/A45/A56 1200 Model Numbers
MPa
A70 2100 A10-FR01B 2.9
A90/A100 2500 A10-FR01C/H 5.4
A145 3300 A16/A22/A37/A56-*-R-01-B 3.5
A16/A22/A37/A56-*-R-01-C 6.5
A16/A37/A56-*-R-01-H 7.9
A70/A90/A100/A145-*-R01B 2.3
A70/A90/A100/A145-*-R01C 3.2
A70/A90/A100/A145-*-R01H 4.0
A70/A90/A100/A145-*-R01K 4.7
Adjustment of Delivery
Turning the flow adjustment screw clockwise, decreases
delivery.
Adjustable volume
with each full turn Minimum adjustment flow
Model of the adjustment
screw cm3/rev
cm3/rev
A10 1.1 2.0
A16 1.4 4.0
A22 2.0 6.0
A37 2.9 10
A56 3.9 12
A70 4.4 36
A90 4.8 56
A100 5.2 62
A145 7.2 83
Control Piston
Spool
Drain Port
Pivot
Flow Adj. Screw
Shaft
OUT
IN
Yoke
■ Features
● High efficiency ● Low noise level
The efficiency properties in case of “A16”from are high In the “A16” pump, the noise level is as low as 57.3 dB(A)
efficiencies to be shown below. [at the full cut-off pressure 21 MPa with speed 1500 r/min
one metre horizontally away from pump head cover.]
80 32 12 70
Efficiency %
28
Output Flow
Output Flow L/min
60
t-off
60 24 9
Input Power kW
20 Full Cu
er
50
ow
40 16 6
P
ut
Inp 12
40
20 8 3 0 4 8 12 16 20 21
4 Pressure MPa
0 0
0 4 8 12 16 20 21
Pressure MPa
■ Control Type
A Series
When the system pressure increases and comes close
Output Flow
Pressure
to the preset cut-off pressure, the pump flow decreases
"01" Compensator 31
automatically while maintaining the set pressure as it
Type
M
O is.
Pressure
Output Flow
Solenoid-two PL PH This type of control is ideal for an application where
Pressure SOL SOL the output power of the actuator has to be controlled
"02" "ON" 53
Control "OFF" in two different load pressures while keeping the
Type actuator speed nearly constant.
PL PH
M
O
Pressure
Compensator
to be kept at their lowest levels.
"03" with SOL SOL 61
Unloading "OFF" "ON"
• The pump can be used in combination with the
Type M
multistage pressure control valve.
Pressure
O
L)
Electro-
Output Flow
specific amplifier.
O
(S Input Current i 1 L)
Electro-
Hydraulic This type of control has the pressure sensor and tilt
Proportional angle sensor in the pump. The pump is used with the
"04E" Pressure & external amplifier (amplifier is integrated into pump 72
Flow in case of "04EH").
L)
Proportional
M
O Pressure
Pressure & (S Input Voltage L) • Linearity of input characteristics is excellent and
"04EH" easy to set. 82
Flow
Control • Hysteresis is lower, repeatability and reproducibility
Type are fine.
(OBE Type)
Two-Pressure QH
This type of control is suitable for an application like
Output Flow
Two-Flow
PH
starts.
Pres. M PL PH
O
Pressure
SOL"OFF"
Two-Pressure QH
This pump control is suitable for machining found
Output Flow
Two-Flow SOL"ON"
QL on machine tool, where machining starts after the
"06" Control Type PL 92
changeover from rapid advance, to feed has been
by Solenoid
made.
PH
Valve PL PH
M
O
Pressure
Output Flow
valve or multistage pressure control valve. By
Control Type
"07" controlling the pilot pressure, the full cut-off pressure 93
Pressure
can be remote-controlled according to your
Compensator
M
requirements.
O
Pressure
Pressure
QH
Simple Two- flow automatically decreases to “QL.”
"00- Pressure QL • This type of control is suitable for an application 109
Z500" Two-Flow QH like the press, where switching from rapid
Control Type QL
advance to feed is required just when the press
PL PH
Pressure → (pressurizing) starts.
• The PH pressure can be remote-controlled with a
separately located relief valve. With this type of
control, it is easy to change the applied pressure
setting when materials or shapes of the press are
changed.
A Series
Graphic Symbol
M
O M
O
■ Specifications
Geometric Minimum Operating Pressure Shaft Speed Range Approx. Mass
Model Numbers Displacement Adj. Flow MPa r/min kg
cm3/rev cm3/rev Rated★2 Intermittent★1 Max. Min. Flange Mtg. Foot Mtg.
A10-FR01B-12 5.1
10.0 2 16 21 1800 600 —
A10-FR01C/H-12 8.5
A16-*-R-01-*-*-K-32 15.8 4 16 21 1800 600 16.5 18.7
A22-*-R-01-*-*-K-32 22.2 6 16 16 1800 600 16.5 18.7
A37-*-R-01-*-*-K-32 36.9 10 16 21 1800 600 28.0 32.3
A56-*-R-01-*-*-K-32 56.2 12 16 21 1800 600 35.0 39.3
A70-*R01*S-60 70.0 36 25 28 1800 600 58.5 70.5
A90-*R01*S-60 91.0 56 25 28 1800 600 72.5 93
A100-*R01*S-10 100 62 21 21 1800 600 72.5 93
A145-*R01*S-60 145 83 25 28 1800 600 92.5 117.7
★1. Whenever setting pressure, make sure the full cut-off pressure never exceeds
the maximum intermittent pressure. One Cycle Time
★2. Care should be taken in cases of used at a higher pressure than the rated
pressure, because operating terms may be restricted. For example, if used as 1/5 of One Cycle
per maximum illustrated operating conditions, intermittent time at maximum (Max. 6s)
flow is restricted to under 1/5 of one cycle time and under six seconds
Pressure
(Viewed
Shaft End )
H: 1.2 - 21
F: Flange from None:
A22 Mtg. 01: Pressure B: 1.2 - 7 Axial Port
K: 32
(22.2 cm3/rev) Compensator C: 1.2 - 16
Keyed Shaft
A37 L: Foot R: Clockwise ★2 Type S:
Mtg. (Normal) B: 1.2 - 7 Side Port 32
(36.9 cm3/rev)
C: 1.2 - 16
A56 H: 1.2 - 21 32
(56.2 cm3/rev)
A70 -F R 01 B S -60
Direction of Pres. Adj. Range Design
Series Number Mounting Control Type Port Position
Rotation MPa Number
B: 1.2 - 7
A10 F: Flange★1
C: 2.0 - 16 — 12
(10.0 cm3/rev) Mtg.
H: 2.0 - 21
(Viewed
Shaft End )
A70 from 60
(70.0 cm3/rev)
01: Pressure
A90 F: Flange Compensator B: 1.2 - 7 60
(91.0 cm3/rev) Mtg. Type
R: Clockwise★2 C: 1.5 - 16
(Normal) S: Side Port
A100 H: 1.8 - 21
L: Foot 60
(100 cm3/rev) K: 2.0 - 28
Mtg.
A145
60
(145 cm3/rev)
★ 1. When A10 pump is used as the foot Mtg., order the Mtg. Bracket kit shown below separately. Refer to page 20 for dimensions of the Mtg.
bracket.
Note: The mounting bracket kit consists of a mounting bracket, two hex. bolts and two plain washer.
Mtg. Bracket Kit Numbers Approx. Mass kg
LP-1A-10 2.2
★ 2. Available to supply pump with anti-clockwise rotation (Except A100). Consult Yuken for details.
★ In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
● Details of the pipe flange kits are shown on page 262.
A Series
Maximum Operating Pressure MPa 16 16
Geometric Displacement cm /rev
3
45.0 219
Shaft Speed Range r/min 600 - 1800 600 - 1500
SOL
High Pressure Rubber Hose Model Rubber Hose Size
A16
3/4”× 700 mm
A22
A37
3/4”× 2000 mm
A56
● Conditions
Model Oil Temperature
Shaft Speed : 1500 r/min
Hydraulic Fluid : ISO VG 32 Oil A10 - A56 50℃ (20 mm2/s)
Oil Temperature : See right table A70 - A145 40℃ (32 mm2/s)
■ Result of Measurement
Full Cut-off Pressure at Full Response Time
Overshoot Pressure
t1 Pressure Flow ms
t2 Model PS
P1 P2
t t MPa
MPa MPa
Pressure
PS 1 2
P2 P2
A22 16 2 30 ★
72 ★
5.9
Time
A37 16 2 40 ★
78 ★
7.8
SOL
OFF ON OFF A56 16 2 38 ★
88 ★
7.6
★ Response time except A16, A22, A37 and A56 is measured Yoke travel.
Efficiency %
80 Overall Efficiency 20 80 20
Output Flow
Input Power kW
Input Power kW
40 10 8 40 10 8
6 6
r
Power tP owe
Input Inpu
5 4 5 4
2 2
0 0 0 0
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
■ Input Power
N=1500 r/min N=1800 r/min
8 8
P=MPa
7 7 P=20
P=MPa P=18
6 P=20 6 P=16
P=18
Input Power kW
Input Power kW
P=16 P=14
5 5
P=14 P=12
4 P=12 4 P=10
P=10 P= 8
3 P= 8 3
P= 6
P= 6
2 P= 4 2 P= 4
P= 2 P= 2
1 1
0 5 10 15 20 0 5 10 15 20
Output Flow L/min Output Flow L/min
0.8
1.0
Drain L/min
0.6
A10-FR01C
1500 r/min
0.4 A10-FR01C
0.5 1800 r/min
w
Full Flo
1500 r/min A10-FR01B
0.2
0 r/min
A10-FR01B 15 00, 180
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
70 70
Full Flow
Noise Level dB(A)
Full Flow
60 60
50 50
Full Cut-off Full Cut-off
40 40
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
Typical Performance Characteristics of Type A16 at Viscosity 20 mm2/s [ISO VG32 Oils, 50°C]
A Series
N=1500 r/min N=1800 r/min
100 100
Volumetric Efficiency Volumetric Efficiency
Overall Efficiency Overall Efficiency
80 80 32 12
28
Output Flow
Efficiency %
Efficiency %
Output Flow
Input Power kW
60 24 9 60 24 9
Input Power kW
20 20
er
40
er 16 6 40 ow 16 6
ow u tP
ut P 12 Inp 12
Inp
20 8 3 20 8 3
4 4
0 0 0 0
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
■ Input Power
N=1500 r/min N=1800 r/min P=MPa
12 12
P=MPa P= 20
P= 20 P= 18
10 10
P= 18 P= 16
P= 16 P= 14
Input Power kW
Input Power kW
8 8
P= 14 P= 12
P= 12 P= 10
6 6
P= 10 P= 8
P= 8 P= 6
4 4
P= 6 P= 4
P= 4 P= 2
2 2
P= 2 P=0.7
P=0.7
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Output Flow L/min Output Flow L/min
1800 r/min
A16-*-R-01-C
0.5 1
A16-*-R-01-C 1500 r/min in
r/m
1500 r/min A16-*-R-01-B 1800
1500,
A16-*-R-01-B Full Flow
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
80 80
Noise Level dB(A)
70 70
Full Flow
Full Flow
60 60
50 50 Full Cut-off
Full Cut-off
40 40
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
Efficiency %
Volumetric Efficiency Volumetric Efficiency Overall Efficiency
80 Overall Efficiency 40 80 40
Output Flow
Input Power kW
Input Power kW
10 10
r
owe
20 8 20 8
Po wer ut P
nput
6 Inp 6
I
10 4 10 4
2 2
0 0 0 0
0 4 8 12 16 0 4 8 12 16
Pressure MPa Pressure MPa
■ Input Power
N=1500 r/min N=1800 r/min
10 10
P=MPa P=MPa
P=14 P=14
8 8
P=12 P=12
Input Power kW
Input Power kW
P=10 P=10
6 6
P= 8 P= 8
P= 6 P= 6
4 4
P= 4 P= 4
P= 2 P= 2
2 2
P= 1 P= 1
0 10 20 30 40 50 0 10 20 30 40 50
Output Flow L/min Output Flow L/min
A22-*-R-01-C
A22-*-R-01-C
Drain L/min
1.0 2
1800 r/min
1500 r/min
0.5 1
A22-*-R-01-B
1500 r/min Full Flow in
A22-*-R-01-B 1500, 1800 r/m
0 4 8 12 16 0 4 8 12 16
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
80 80
Noise Level dB(A)
70 70
Full Flow
Full Flow
60 60
Typical Performance Characteristics of Type A37 at Viscosity 20 mm2/s [ISO VG32 Oils, 50°C]
A Series
N=1500 r/min N=1800 r/min
100 100
Efficiency %
Efficiency %
Volumetric Efficiency Volumetric Efficiency
Overall Efficiency Overall Efficiency
80 80 80
Input Power kW
Input Power kW
40 20 er 40 20
ow er ut Pow
ut P Inp
Inp
20 10 20 10
0 0 0 0
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
■ Input Power
Input Power kW
P=14
15 P=12 15 P=12
P=10 P=10
P= 8 P= 8
10 10
P= 6 P= 6
P= 4 P= 4
5 5 P= 2
P= 2
P= 1 P= 1
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Output Flow L/min Output Flow L/min
A37-*-R-01-C *-R
1800 r/min A37-
2 2 1500 r/min
Drain L/min
-01-C
*-R
A37-
1 1 in
-B r/m
-R-01 1800
low
1500 r/min 7 - *
A3 ,
A37-*-R-01-B
1 500 ll FFu
0 4 8 12 16 20 21 0 4 8 12 16 2021
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
80 80
Noise Level dB(A)
70 70
Full Flow
Full Flow
60 60
40 40
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
Efficiency %
80 Overall Efficiency 80 Overall Efficiency
60 60 60 120 60
Output Flow
Input Power kW
Input Power kW
Output Flow 100 100
80 40 80 40
r
owe
60 60
er tP
t Pow Inpu
Inpu 40 20 40 20
20 20
0 0 0 0
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Pressure MPa Pressure MPa
■ Input Power
P=MPa P=MPa
N=1500 r/min N=1800 r/min
40 P=20 40 P=20
P=18 P=18
35 35
P=16 P=16
Input Power kW
Input Power kW
30 P=14 30
P=14
25 P=12 25 P=12
20 P=10 20 P=10
P= 8 P= 8
15 15
P= 6 P= 6
10 10 P= 4
P= 4
5 P= 2
5 P= 2
-H
-R-01
3 3 A56-*
Drain L/min
-01-C
*-R
n A56-
2 /mi 2
0r
180
min
1 0 r/ 1 A56-*-R-01-B
150 1500 r/min Full Flow
1500, 1800 r/min
0 4 8 12 16 2021 0 4 8 12 16 20 21
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
80 80
Noise Level dB(A)
60 60
Full Cut-off Full Cut-off
50 50
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Typical Performance Characteristics of Type A70 at Viscosity 20 mm2/s [ISO VG32 Oils, 50°C]
A Series
Volumetric Efficiency N=1500 r/min Volumetric Efficiency N=1800 r/min
Efficiency %
Efficiency %
100 100
Overall Efficiency
Input Power kW
Input Power kW
r
er 80 owe 40
Pow ut P
40
t Inp
Inpu
20 20
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure MPa Pressure MPa
■ Input Power
N=1500 r/min N=1800 r/min P=MPa
60 P=MPa 60 P=24
P=24 P=22
50 P=22 50 P=20
P=20 P=18
Input Power kW
Input Power kW
P=18 P=16
40 40
P=16 P=14
P=14 P=12
30 P=12 30
P=10
P=10
P= 8 P= 8
20 20
P= 6 P= 6
P= 4 P= 4
10 10
P= 2 P= 2
6 6
Full Cut-off Power kW
5 5
off
ut-
in
Drain L/min
r/m lC in
Ful r/m
4 4
00 00
18 in 0, 18
150
3 r/m 3
0
150
2 2
low
in
ll F
/m
0r
1 1 Fu ,1
80
0
150
0 5 10 15 20 25 0 5 10 15 20 25
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
80 80
Noise Level dB(A)
70 70 Full Flow
Full Flow
60 60
Full Cut-off Full Cut-off
50 50
0 5 10 15 20 25 0 5 10 15 20 25
Pressure MPa Pressure MPa
Efficiency %
100 100
Overall Efficiency Overall Efficiency
80 80
60 60
Input Power kW
Input Power kW
130 60 150 60
er
wer
120
ow
40 140 40
t Po ut P
Inpu Inp
20 20
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure MPa Pressure MPa
■ Input Power
P=MPa
N=1500 r/min N=1800 r/min P=25
70 70
P=MPa P=24
P=25 P=22
60 P=24 60
P=20
P=22
50 50 P=18
P=20
Input Power kW
Input Power kW
P=18 P=16
40 P=16 40 P=14
P=14 P=12
30 P=12 30 P=10
P=10 P= 8
P= 8 P= 6
20 P= 6 20
P= 4
P= 4
10 P= 2 10 P= 2
6 8
5
Drain L/min
in 6
r/m
4 0
80
3
1
in 4 Full Cut- off
r/m /min
1800 r
00
2 15 in
2 1500 r/m 1800 r/min
ull Flow
1 1500 r/min
F
0 5 10 15 20 25 0 5 10 15 20 25
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
80 80
Noise Level dB(A)
70 70 Full Flow
Full Flow
60 60 Full Cut-off
Full Cut-off
50 50
0 5 10 15 20 25 0 5 10 15 20 25
Pressure MPa Pressure MPa
Typical Performance Characteristics of Type A100 at Viscosity 20 mm2/s [ISO VG32 Oils, 50°C]
A Series
N=1500 r/min N=1800 r/min
Efficiency %
Efficiency %
100 100 Volumetric Efficiency
Volumetric Efficiency
80 Overall Efficiency 80 Overall Efficiency
60 60
Input Power kW
Input Power kW
140 60 170 60
er
wer 130 Pow
t Po
160 40
40 ut
Inpu Inp
20 20
0 0
0 5 10 15 20 21 0 5 10 15 20 21
Pressure MPa Pressure MPa
■ Input Power
P=MPa
N=1500 r/min N=1800 r/min P=20
70 70
P=18
P=MPa
60 P=20 60 P=16
P=18 P=14
50 50
Input Power kW
Input Power kW
P=16 P=12
P=14 P=10
40 40
P=12
P= 8
P=10
30 30 P= 6
P= 8
P= 6 P= 4
20 20
P= 4 P= 2
P= 2
10 10
0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160 180 200
Output Flow L/min Output Flow L/min
6 6
5 5
Full Cut-off Power kW
t-off
Full Cur/min
4 in 4 1800
r/m
Drain L/min
00 min
18 in 1500 r/
3 r/m 3 1800 r/min
00
15 1500 r/min
2 2
Flow
1 1 Full
0 4 8 12 16 20 21 0 4 8 12 16 20 21
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
90 90
Noise Level dB(A)
80 80
Full Flow
Full Flow
70 70
Efficiency %
100 100
Overall Efficiency Overall Efficiency
80 80
60 60
Input Power kW
Input Power kW
200 120 250 120
wer
80 240 80
r
tP owe t Po
Inpu 40 Inpu 40
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure MPa Pressure MPa
■ Input Power
P = MPa
N=1500 r/min N=1800 r/min
120 120 P = 26
P = MPa P = 24
P = 26 P = 22
100 P = 24 100
P = 20
P = 22
Input Power kW
Input Power kW
P = 18
80 P = 20 80 P = 16
P = 18
P = 16 P = 14
60 P = 14 60 P = 12
P = 12 P = 10
P = 10 P= 8
40 P= 8 40
P= 6
P= 6
P= 4 P= 4
20 20 P= 2
P= 2
12.5 12.5
Full Cut-off Power kW
10.0 10.0
Drain L/min
in
7.5 7.5 -off
r/m
Cut in
Full800 r/m
0
1 80 in 1
5.0 r/m 5.0 min
0 0 0 r/
15 150
in
0 r/m
2.5 2.5 , 180
1500
low
Full F
0 5 10 15 20 25 0 5 10 15 20 25
Full Cut-off Pressure MPa Pressure MPa
■ Noise Level [One metre horizontally away from pump head cover]
N=1500 r/min N=1800 r/min
90 90
Noise Level dB(A)
80 80 Full Flow
Full Flow
70 70
Full Cut-off
Full Cut-off
60 60
0 5 10 15 20 25 0 5 10 15 20 25
Pressure MPa Pressure MPa
A Series
Flow Adj. Screw Filling Port ★1
13 Hex. (22 Hex. Head. Plug Furnished)
Pressure Adj. Screw
13 Hex. DEC.
INC. Fully Extended 44.5 Drain Port ★3
186 Rc3/8 Thd.
Fully Extended 90.5 6.5
102
52.5 25
19.02 Dia.
4.79
4.76
103
19.05
21.24
21.08
85
65
82.50 Dia.
12
167
41
31
82.55
Suction Port ★2, ★3 25 25 Discharge Port ★2, ★3 10.5 93 Dia.
Rc 1/2 Thd. 64.5 64.5 Rc 1/2 Thd. 131 106
34 Dia. 3.5 Deep 34 Dia. 3.5 Deep
156 130
159.5
●A10-FR01B
F
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two suction and discharge ports at your option. Keep the remaining ports plugged.
★3. As the tightening torques of suction, discharge and drain port fittings, conform to the below.
Tightening Torque
Name of Port
Nm
Suction
65 - 75
Discharge
Drain 40 - 50
Lock Nut
17 Hex. Fully Extended 219 44.5 Filling Port★1
(22 Hex. Head Plug Furnished)
59 6.5
26.5 Drain Port
Flow Adj. Screw 16 16 Pressure Adj. Screw Rc3/8 Thd.
17 Hex. 17 Hex.
DEC. INC.
4.79
19.02 Dia.
25 4.76
19.05
21.24
21.08
109
96
82.50 Dia.
62
18
11
187
47.6
82.55
M10 Thd. 17 Deep R12
Suction Port 8 Places 95 Dia.
22.2 12 106
19 Dia.
32.5 32.5 Discharge Port 172 130
19 Dia. 188
50 56.5 95
95 27.5 72.5 72.5
180
74 74 22.2
150.5
Surface of Suction Port Surface of Discharge Port
A Series
Lock Nut
Filling Port★1
17 Hex. Fully Extended 247 59
(22 Hex. Head Plug Furnished)
77 9.5
Flow Adj. Screw Pressure Adj. Screw 30 Drain Port
17 Hex. 17 Hex. Rc1/2 Thd.
13 19
DEC. INC.
22.20 Dia.
6.38
32 6.35
M10 Thd. 19 Deep
22.23
25.01
24.85
112
8 Places
105
101.55 Dia.
68
202
58.7
101.60
14
25
Suction Port R14
32 Dia. 120 Dia.
30.2 Discharge Port 12 146
36 36 32 Dia. 195 174
202
14 Dia. Through
28 Dia. Spotface
4 Places
102
15
14
3
60 74 120
115 39 95 95
230
58.7
86 86 30.2
178.5
Surface of Suction Port Surface of Discharge Port
Flow Adj. Screw Pressure Adj. Screw 43.5 Drain Port (Bath Sides)★2 Surface of Drain Port
17 Hex. 17 Hex. Rc3/4 Thd.
13 19 41 49
DEC. INC.
7.97
31.70 Dia.
40 7.94
35.32
35.14
138
31.75
101.55 Dia.
25
90
77
14
236
58.7
101.60
Suction Port R14
35 Dia. 30.2 M10 Thd. 19 Deep 12 120 Dia. 146
8 Places
38 38 Discharge Port 207 174
32 Dia. 232
14 Dia. Through
28 Dia. Spotface
4 Places
102
14
15
3
60 77 120
115 42 95 95
230
58.7
A Series
Drain Port (Both Sides)★2
Rc3/4 Thd.
Surface of Discharge Port Surface of Suction Port
40
27 Dia. Spotface
4 Places (Rear side) 7.97
31.70 Dia.
Y 7.94 X
182
14
31.75
35.32
35.14
90
126.95 Dia.
18
114.4
52.4
180
127.00
14
118
Discharge Port 19.5
26 Dia. 35 Dia. Spotface
16 114.4
26.2 2 Places (Rear side)
M10 Thd. 17 Deep 18 134
4 Places 246.5 181
211
Eye Bolt
M10
Filling Port★1
(22 Hex. Head Plug Furnished)
Suction Port
38 Dia.
Flow Adj. Screw Pressure Adj. Screw
17 Hex. 17 Hex.
69.9
DEC. INC.
View Arrow X
★1. Install the pump that the “Filling Port” is at the top.
★2. Use either port of the two drain port at your option. Keep the remaining port plugged.
★3. Case drain port is available for use when draining hydraulic fluid from pump casing.
22 Dia. Through
43 Dia. Spotface
4 Places
130
26
24
125 77 171
195 37 130 130
320
38.05 Dia.
190.5
Y 9.58
42.36
42.18
38.10
9.53
152.35 Dia.
113
X
161.6
58.7
152.40
127
Discharge Port
32 Dia.
22 21.5 Dia. Through 161.6 R22
M10 Thd. 19 Deep 39 Dia. Spotface
30.2 23
4 Places 4 Places (Rear Side)
270
Case Drain Port★3
5 Hex. Soc.
Eye Bolt
Flow Adj. Screw Pressure Adj. Screw M10
17 Hex. 17 Hex. Filling Port★1
(27 Hex. Head Plug Furnished)
DEC. INC. Suction Port
48 Dia.
77.8
View Arrow Y
M12 Thd. 19 Deep
42.9 4 Places
270
View Arrow X
★1. Install the pump that the “Filling Port” is at the top.
★2. Use either port of the two drain port at your option. Keep the remaining port plugged.
★3. Case drain port is available for use when draining hydraulic fluid from pump casing.
25
24
3
A Series
Drain Port (Both Sides)★2 Surface of Discharge Port Surface of Suction Port
Rc3/4 Thd.
112 112
Flow Adj. Screw 357.5 112 Surface of Drain Port 72 72 Surface of Drain Port
17 Hex. 89 23
DEC. 13
70
44.40 Dia.
11.14
198.5
11.11
49.39
49.21
44.45
110
152.35 Dia.
Y X
228.6
58.7
YUKEN
152.40
141
Discharge Port
32 Dia.
24 228.6
30.2 21.5 Dia. Through R22
26 39 Dia. Spotface 273
M10 Thd. 19 Deep 299.5 4 Places (Rear Side)
4 Places
Case Drain Port★3
5 Hex. Soc.
Eye Bolt
Filling Port★1 M10
(27 Hex. Head Plug Furnished) Pressure Adj. Screw
143 17 Hex.
INC.
Suction Port
48 Dia.
114
77.8
M12 Thd. 19 Deep
4 Places
42.9
299.5
View Arrow Y
View Arrow X
★1. Install the pump that the “Filling Port” is at the top.
★2. Use either port of the two drain port at your option. Keep the remaining port plugged.
★3. Case drain port is available for use when draining hydraulic fluid from pump casing.
22 Dia. Through
43 Dia. Spotface
4 Places
187.3
30
29
3
A10ーFーRー01 X
21 36 23 43 35 34 33 12 37 34 8 5 31 11 29 22 32 13 15 14 3 20 7 40 1 Name of
Item Part Numbers Qty.
39 Parts
25 25 Bearing 6204 1
27
30
26 Oil Seal TCN24408Y 1
X 6 28 Bearing HMK1215 1
26
30 O-Ring SO-NB-G50 1
38
42 31 O-Ring SO-NB-G120 1
32 SO-NB-P14 1
IN OUT
4 O-Ring
47
46
33 O-Ring SO-NB-P12 5
45 34 O-Ring SO-NB-P6 2
35 O-Ring SO-NB-P9★ 1
54 O-Ring AS568-018 (NBR-70) 1
33 41 2 28 19 18 17 9 24 10 16
62 O-Ring SO-NB-P10 1
51 52 53 54 55 56 57 58 59 63 60 61 62
★O-Ring of Item ㉟ shall be SO-NB-P12 in case
of A10-FR01-B.
Section X-X
A16/A22/A37/A56ー*ーRー01
56 46 50 2 33 58 50 40 20 49 2 50 8 4 32 58 38 34 62 5 28 29 11 1
16
37
X X 45
30 49 42 23 26 24 22 31 21 39 44 25 47 41 18 48
13 53
35
52
15
43
57
51
14
61
60
59
Section X-X
17 55 6 36 27 12 10 9 19 3 7
Part Numbers
Item Name of Parts Qty.
A16 -*-R-01 A22-*-R-01 A37-*-R-01 A56-*-R-01
16 Bearing 6305 6307 NUP 207E 1
17 Bearing HMK 1715 Z30-1303-PK410300-8 HMK 2025V2 HMK 2530V2 1
35 Oil Seal TCN 254511 TCN 355511 TCN 355511 1
36 Gasket 130-PK211969-1 1316-PK211970-9 1307-PK21197-7 1
37 O-Ring SO-NA-G55 SO-NA-G75 1
40 O-Ring SO-NA-G25 SO-NA-G30 SO-NA-P36 2
41 O-Ring SO-NB-P12 SO-NB-P10A 1
42 O-Ring SO-NB-P9 1
43 O-Ring AS568-017 (NBR-70) 1
44 Seal Washer W8 1
62 O-Ring SO-NB-P14 1
A70/A90/A100-*R01*S
A Series
63
12 3 67 36 56 32 30 1 4
A
46
51
53 71 9
P X
O 35 26 X 42
Z
45 27 60
64 55 62
34 6
Z
40
38
48
52
66
47 54 2 39 61 5 33 31 13 28 37 16 14 15 17 29 65
59 22 44
58 44 11 21 20 18 8 10 70 50 7 44
69 9 10
68
23
19
72
24
Section Z-Z 43
Section X-X Section X-X
(Only for "A70") Detail "A"
Part Numbers
Item Name of Parts A90-*R01*S Qty.
A70-*R01*S
A100-*R01*S
5 Gasket 1314E-PK211972-5 1310E-PK211973-3 1
22 Back Up Ring 1310E-PK412440-0 1310E-PK412440-0 1
38 Bearing NUP 208EX50 NUP 210E 1
39 Needle Bearing HMK 3030V2 HMK 3530BV2 1
40 Oil Seal TCN 355511 (FKM) TCN 456812 (FKM) 1
42 O-Ring SO-FA-G85 SO-FA-G95 1
43 O-Ring SO-NA-P18 SO-NA-P18 1
44 O-Ring SO-NB-P9 SO-NB-P9 3
67 O-Ring SO-NB-P14 SO-NB-P18 1
68 O-Ring SO-NB-P5 SO-NB-P5 1
69 Seal Washer W10 ―― 1
A145-*R01*S
58 52 36 56 63 46 15 8 7 33 69 3 60 37 73 28 5 59 1 61
75 76
14 9
X X 46 39
65 62 54
51 25 41
75 65 68
70 29 4
35 27 64
67 44
71
57
72
53 74 2 40 6 34 11 32 30 13 38 10 12 16 31
19 56 22 17 50 48 47 49 66 20 57 23
45
21
24
62
18 43 59
Section X-X
A Series Variable Displacement Piston Pumps, Solenoid Two Pressure Control Type
A Series
Graphic Symbol Performance Characteristics
PL PH
Output Flow
SOL SOL
"OFF" "ON"
M
O
PL PH
Pressure
■ Specifications
Geometric Minimum Operating Pressure Minimum Shaft Speed Range Approx. Mass
Model Numbers Displacement Adj. Flow MPa Adj. Pres. r/min kg
cm3/rev cm3/rev Rated★2 Intermittent★1 MPa Max. Min. Flange Mtg. Foot Mtg.
A16-*-R-02-*-K*-32 15.8 4 16 21 1.2 1800 600 24.5 26.7
★1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
★2. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details.
■ Solenoid Ratings
Frequency Voltage (V) Current & Power at Rated Voltage
Electric source Coil Type
(Hz) Source Rating Serviceable Range Inrush (A)★2 Holding (A) Power (W)
50 100 80 - 110 2.42 0.51
A100 100 2.14 0.37
60 90 - 120
110 2.35 0.44
50 96 - 132 2.02 0.42
A120 120
60 108 - 144 1.78 0.31
AC —
50 200 160 - 220 1.21 0.25
A200 200 1.07 0.19
60 180 - 240
220 1.18 0.22
50 192 - 264 1.01 0.21
A240 240
60 216 - 288 0.89 0.15
D12 12 10.8 - 13.2 2.45
DC (K Series) D24 — 24 21.6 - 26.4 — 1.23 29
D48 48 43.2 - 52.8 0.61
R100 100 90 - 110 0.33
AC→DC Rectified(R) ★1
50/60 — 29
R200 200 180 - 220 0.16
★1. R type models with built-in current rectifier is recommended for shockless operation with AC power.
★2. Inrush current in the above table show rms values at maximum stroke.
A16
32
(15.8 cm3/rev)
AC
(Viewed
Shaft End )
A100, A120
A22 F: Flange from A200, A240
02: None: 32
(22.2 cm3/rev) Mtg.
Solenoid Two Axial Port K: DC
Pressure Control Keyed Shaft D12, D24
A37 L: Foot R: Clockwise★1 Type S: Side Port D48 32
(36.9 cm3/rev) Mtg. (Normal)
R (AC→DC Rectified)
R100, R200
A56
32
(56.2 cm3/rev)
A70 AC
60
( )
(70.0 cm3/rev) A100, A120
F: Flange Viewed from A200, A240
Mtg. Shaft End 02:
A90 DC
Solenoid Two Pressure S: Side Port 60
(91.0 cm3/rev) D12, D24
L: Foot R: Clockwise ★1
Control Type
D48
Mtg. (Normal)
A145 R (AC→DC Rectified) 60
(145 cm3/rev) R100, R200
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
■ Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 35 to 42.
A Series
A22-F-R-02-K
Fully Extended 256.5
2 3
Pilot Port "PP2"
141.5 Rc1/4 Thd.
95 136
74.5
Lock Nut 112 44.5 Electrical Conduit
14 Hex. 3 51.5 Connection
59 6.5 G1/2 Thd. (Both Ends)
1
Filling Port
26.5 (22 Hex. Head Plug Furnished)
"PP1" Drain Port
Rc3/8 Thd.
"PP2"
194.5
176
4.79
25
145
4.76
272.5
117
96
X
62
82.50 Dia.
18
12
82.55
19.02 Dia.
21.24
21.08
19.05
R12
95 Dia.
12 106
Lock Nut
17 Hex. 172 130
188
Pressure Adj. Screw (PH)
14 Hex.
Works at Solenoid INC.
Energised
2
Pilot Port "PP1"
16 23 Rc1/4 Thd.
DEC.
161
47.6
★1. Install the pump so that the "Filling Port" is at the top.
★2. The pilot port provided is for connecting a control valve, if multistage pressure control is required.
★3. The pilot port "PP2" is not provided for N.American Design Standard.
30 Drain Port
"PP1" Rc1/2 Thd.
"PP2"
198.5
180
32 6.38
149
288.5
X
121
6.35
105
101.55 Dia.
68
58.7
101.60
25
14
25.01
24.85
22.20 Dia.
R14
22.23
120 Dia.
Front Side : Discharge Port 32 Dia. 146
30.2 12
Rear Side : Suction Port 32 Dia.
178.5 174
M10 Thd. 19 Deep
4 Places
202
2
Pilot Port "PP1"
Pressure Adj. INC. Rc1/4 Thd.
13 26
Screw (PH)
14 Hex. Pressure Adj. Screw (PL)
Works at Solenoid
6 14 Hex.
Energised Works at Solenoid INC.
De-energised
Flow Adj. Screw
5 Hex. Soc.
DEC.
165
86 86
★1. Install the pump so that the "Filling Port" is at the top.
★2. The pilot port provided is for connecting a control valve, if multistage pressure control is required.
★3. The pilot port "PP2" is not provided for N.American Design Standard.
A Series
Fully Extended 292
223.5
40 5 5
41 49
205
7.97
174
X 7.94
321.5
146
90
77
58.7
25
14
Dia.
35.32
35.14
101.55 Dia.
R14
31.75
31.70
3
Pilot Port "PP1"
Pressure Adj. 13 26 Rc1/4 Thd.
Screw (PH) INC. Pressure Adj. Screw (PL)
14 Hex. 6 14 Hex.
Works at Solenoid Works at Solenoid INC.
Energised De-energised
Flow Adj. Screw
5 Hex. Soc.
DEC.
190
100 100
Surface of Surface of
Suction Port Discharge Port
View Arrow X
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. The pilot port provided is for connecting a control valve, if multistage pressure control is required.
★4. The pilot port "PP2" is not provided for N.American Design Standard.
★5. Dimensions show surface of drain port.
217.5
236
X 7.94
202.5
186.5
Y
126.95 Dia.
90
14
18
52.4
114.4
127.00
180
35.32
35.14
31.70 Dia.
Discharge Port
118
35 Dia. Spotface
26 Dia.
31.75
(Rear Side)
19.5 2 Places
M10 Thd. 26.2 114.4
17 Deep 16
4 Places
134
18
181
246.5
211
View Arrow Y
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. The pilot port provided is for connecting a control valve, if multistage pressure control is required.
★4. The pilot port "PP2" is not provided for N.American Design Standard.
★5. Case drain port is available for use when draining hydraulic fluid from pump casing.
A Series
Surface of Discharge Port Surface of Suction Port
2
Drain Port 105 105
Rc3/4 Thd. (Both Sides)
Surface of Drain Port 68 68 Surface of Drain Port
263.5 95
2.5 52
119.5 23 3 4
Pilot Port "PP2" 9.56
Rc1/4 Thd. 9.53
13
63
245.5
226
212
X
196
Y
113
152.35 Dia.
161.6
58.7
152.40
127
Discharge Port
38.05 Dia.
42.36
42.18
32 Dia.
38.10
5
Case drain Port
5 Hex. Soc.
196
De-energised 168
88
77.8
View Arrow Y
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. The pilot port provided is for connecting a control valve, if multistage pressure control is required.
★4. The pilot port "PP2" is not provided for N.American Design Standard.
★5. Case drain port is available for use when draining hydraulic fluid from pump casing.
247.5
214
198
Y
110
152.40Dia.
228.6
58.7
152.35
141
44.40 Dia.
49.39
49.21
Discharge Port
32 Dia.
44.45
De-energised
Flow Adj. Screw
M12 Thd. 19 Deep
17 Hex.
4 Places
229
DEC.
42.9
299.5
View Arrow X
View Arrow Y
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. The pilot port provided is for connecting a control valve, if multistage pressure control is required.
★4. The pilot port "PP2" is not provided for N.American Design Standard.
★5. Case drain port is available for use when draining hydraulic fluid from pump casing.
A Series
Graphic Symbol Performance Characteristics
Output Flow
SOL SOL
"OFF" "ON"
M
O
Pressure
■ Specifications
Geometric Minimum Adj. Operating Pressure Shaft Speed Range
Unloading Pressure
Model Numbers Displacement Flow MPa r/min
MPa
cm3/rev cm3/rev Rated Intermittent Max. Min.
A16-*-R-03-*-K-*-32 15.8 4 16 21 1.2 1800 600
A22-*-R-03-*-K-*-32 22.2 6 16 16 1.2 1800 600
A37-*-R-03-*-K-*-32 36.9 10 16 21 1.2 1800 600
A56-*-R-03-*-K-*-32 56.2 12 16 21 1.2 1800 600
A70-*R03S*-60 70.0 36 25 25 1.2 1800 600
A90-*R03S*-60 91.0 56 25 25 1.2 1800 600
A145-*R03S*-60 145 83 25 25 1.2 1800 600
( )
A100, A120
F: Flange Viewed from 03: A200, A240
A22 None:
Mtg. Shaft End Pressure 32
(22.2 cm3/rev) Axial Port K: DC
Compensator
A37 Keyed Shaft D12, D24
L: Foot R: Clockwise★1 with 32
(36.9 cm3/rev) Mtg. Unloading Type S: Side Port D48
(Normal)
A56 R (AC→DC Rectified)
R100, R200 32
(56.2 cm3/rev)
A70 AC
60
( )
(70.0 cm3/rev) A100, A120
Viewed from A200, A240
Shaft End 03:
F: Flange Mtg.
A90 Pressure Compensator DC
S: Side Port 60
(91.0 cm3/rev) with D12, D24
L: Foot Mtg. R: Clockwise ★1
Unloading Type D48
(Normal)
A145 R (AC→DC Rectified) 60
(145 cm3/rev) R100, R200
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
★2. Please inquire for A220 separatery.
Large)
2
Output Flow
Current i 2
Input
M
O
A16/A22/A37/A56
(Small
Pressure
(Small Input Large) 1
Current i1
2
M
O
A70/A90/A145
(Viewed
Shaft End )
A22 04: B: 1.5 - 6.9 (220 - 1000)
from 32
(22.2 cm3/rev) F: Flange Mtg. Proportional C: 1.5 - 15.7 (220 - 2280)
Electro-Hydraulic K: Keyed Shaft
A37 L: Foot Mtg. Load Sensing
R: Clockwise ★1
Type 32
(36.9 cm3/rev) B: 2 - 6.9 (290 - 1000)
C: 2 - 15.7 (290 - 2280)
A56 H: 2 - 20.6 (290 - 2990)
32
(56.2 cm3/rev)
A70 -F R 04 C S -60
Direction of Design
Series Number Mounting Control Type Pressure Adj. Range MPa Port Position
Rotation Number
A70
60
(70.0 cm3/rev)
(Viewed
Shaft End )
from 04:
F: Flange Mtg. Proportional
A90 C: 1.5 - 16 (220 - 2320)
Electro-Hydraulic S: Side Port 60
(91.0 cm3/rev) H: 1.5 - 21 (220 - 3050)
L: Foot Mtg. Load Sensing
R: Clockwise ★1
Type
A145
60
(145 cm3/rev)
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
★2. Please inquire for A220 separatery.
A Series
Threaded Connection Socket Welding★1 Butt Welding
■ Instructions
● Bleeding Air
In order to get steadily controlled pressure and flow, bleed air by loosening the air vent screw and fill solenoid armature with
operating oil.
● Connection of Surge Cut-off Valve to "A" Series Pump (For A16 to A56 Type)
If using surge cut-off valve (SF1105-A-10), connect between pilot port "PP" of this pump and port "PP" of surge cut-off valve as
pilot piping (refer to symbol below).
Inside diameter of pipe should be more than 8 mm.
Consult Yuken of detail of surge cut-off valve.
i1
"PP"
i2
M
O
Geometric Displacement cm3/rev 15.8 22.2 36.9 56.2 70.0 91.0 145
Rated ★2
16 16 16 16 21 21 21
Operating Pressure MPa
Intermittent★1 21 16 21 21 21 21 21
Max. 1800 1800 1800 1800 1800 1800 1800
Shaft Speed Range r/min
Min. 600 600 600 600 600 600 600
Flow Adj. Range L/min 1 - 28.4 1 - 40 1 - 66 1 - 101 1 - 126 1 - 163 2 - 261
Min. Pres. Required
MPa 1.5 1.5 1.5 2.0 1.0 1.0 1.0
for Flow Adj.
Differential Pres.
(Discharge Pres. MPa 0.37 0.22
-Load Pres.)
Flow Control Step Response★5
ms 70 80 120 125 100 120 210
(0 → Max. Flow)
Hysteresis 3 % or less★1
Rated Current mA 900 700 740 790 820 920 920
Coil Resistance
10
(20°C)
Pres. Adj. Range MPa Refer to Model Number Designation
t1 ★5
80 80 50 55 150 150 160
Step Response ms
t2★5 140 90 80 80 80 120 180
Pres. Control Hysteresis 2 % or less ★1
★1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure. Pres. Step Response
Model Loading Volume
★2. When operating the pump exceeding the rated pressure, operating t1 t2
conditions are restricted. Refer to page 31 for the details.
High Pressure Hose
★3. Specifications of power amplifiers, consult Yuken for details. A16, A22 1.5 → 16 MPa 16 → 1.5 MPa
3/8" × 2 m
★4. The figure mentioned in the above table are those obtained using Yuken's
amplifier. High Pressure Hose
A37, A56 2.0 → 16 MPa 16 → 2.0 MPa
3/4" × 2 m
★5. Step response depends on circuit and operating conditions. Data shown in
the table above is an example based on the condition right. A70, A90 High Pressure Hose
3.0 → 16 MPa 16 → 3.0 MPa
A145 1-1/4" × 2 m
A Series
■ Full Cut-off Pres. vs. Input Signal
● A16/A22/A37/A56 ● A70/A90/A145
24
20 20
"H"
"H"
16 16
"C"
12 12
"C"
8 8
4 "B" 4
0 0
200 400 600 800 900 200 400 600 800 1000
Input Current mA Input Current mA
20
Output Flow L/min
24
10
16
0
200 400 600 800
8 Input Current mA
● A56
0 L/min
200 400 600 800 1000 N=1800 r/min
110
Input Current mA 100
Output Flow
80
● A37 60
40
N=1800 r/min
70 20
50
40 ● A70
30
N=1800 r/min
140
Output Flow L/min
20
120
10
80
0
200 400 600 800 40
Input Current mA
0
200 400 600 800 1000
Input Current mA
● A90
N=1800 r/min ● A145
200
N=1800 r/min
280
160
Output Flow L/min
240
120
Output Flow L/min
200
80
160
40 120
0 80
200 400 600 800 1000
Input Current mA 40
0
200 400 600 800 1000
Input Current mA
229 44.5
2
213 6.5
Cable Departure Filling Port
(For Pres. Control) 167.5 (22 Hex. Head Plug Furnished) 101.5
59 63.2
Drain Port
Rc3/8 Thd.
26.5
25
4.79
177.5
152.5
4.76
X
255.5
96
57.5
12
18
Dia.
21.24
21.08
82.50 Dia.
R12
19.05
19.02
95 Dia.
82.55
12
106
172
130
Pressure Gauge Connection Surface of Suction Port
for Pump Discharge Pressure 187 188
Rc1/4 Thd
262
INC.
57.5
48
47.6
22.2 56
Discharge Port
M10 Thd. 17 Deep 32.5 85 G3/8 Thd.
4 Places
See 3 94 190.5
View Arrow X
G 3/8 Thd.
18.6 Dia. 15°
28 Dia.
A Series
Manual Pressure Adj. Screw INC.
3 Hex. Soc.
Air Vent 3 Hex. Soc.
3 Places
Air Vent 3 Hex. Soc. 308.5 59
3 Places. Cable Departure 1
296.5 9.5 (For Pres. Control)
Manual Flow Adj. Screw
3 Hex. Soc.
110.5 Filling Port
(22 Hex. Head Plug Furnished)
INC.
77
Safety Valve
77.3 Pressure Adj. Screw
30 3 Hex. Soc.
Drain Port
Rc1/2 Thd. INC.
6.38
185.5
147.2
32 6.35
132
X
105
275.5
14
25.01
24.85
22.20 Dia.
7
25
101.60 Dia.
22.23
100.5 115.5
27 1
Pilot Port "PP" Cable Departure
Rc1/4 Thd. (For Flow Control)
85
58.7
47.6
Discharge Port
Suction Port 20 Dia.
32 Dia. 30.2 22.2 M10 Thd. 19 Deep
M10 Thd. 19 Deep 4 Places
4 Places 36 42
83
★1. Cable Applicable:
Outside Dia......8-10 mm View Arrow X
Conductor Area......Not Exceeding 1.5 mm2
DIMENSIONS IN
Foot Mtg. : A37-L-R-04*-K MILLIMETRES
14 Dia. Through
28 Dia. Spotface
4 Places
102
15
14
3
60 74 120
115 39 95 95
230
7.94
147.2
X
283.5
90
7
14
25
35.32
35.14
31.70 Dia.
101.55 Dia.
31.75 R14
120 Dia.
101.60
Pressure Gauge Connection 12 146
for Pump Discharge Pressure
Rc1/4 Thd. 207 174
294
100 116
Cable Departure 1
Pilot Port "PP" 27 (For Flow Control)
Rc1/4 Thd.
47.6
85
View Arrow X
DIMENSIONS IN
Foot Mtg. : A56-L-R-04*-K MILLIMETRES
14 Dia. Through
28 Dia. Spotface
4 Places
102
14
15
3
60 77 120
115 42 95 95
230
A Series
Adj. Screw INC.
3 Hex. Soc.
1
344.5 Drain Port (Both Sides)
Rc3/4 Thd.
196.5 Safety Valve INC.
Air Vent
Pilot Port Pressure Adj. Screw
3 Hex. Soc. 227.5
Rc1/4 Thd. 169 3 Hex. Soc.
3 Places
Manual Flow INC.
196.5 62 Secondary Pressure 140 95 Surface of Suction Port
Adj. Screw Gauge Connection
3 Hex. Soc. 191.5 for Pump Discharge 104.3
Pressure
Air Vent 137 19.5 Rc1/4 Thd.
3 Hex. Soc. 73 73
3 Places
3 65 9.5
Cable Departure
(For Flow Control)
40 7.97
Tank Port
31.75 Dia.
7.94
Rc3/8 Thd.
196.5
31.70
35.32
35.14
137
120
14
X
127.00 Dia.
90
83
50
114.4
180
126.95
18
118
30.2
14
35 Dia. Spotface
Primary Pressure 16 (Rear Side)
Gauge Connection for 2 Places
114.4
Pump Discharge Pressure 58.7 18
Rc1/4 Thd. 27 Dia. Spotface 134
215 (Rear Side)
M10 Thd. 17 Deep 4 Places
4 Places 181
276
Discharge Port 211
25 Dia.
Suction Port
38 Dia.
69.9
★1. Use either port of two drain ports at your option. Keep the remaining 35.7
port plugged. 246.5
★2. Case drain port is available for use when draining hydraulic fluid Case Drain Port 2
DIMENSIONS IN
Foot Mtg. : A70-LR04*S MILLIMETRES
42.5
22 Dia. Through
43 Dia. Spotface
127 Dia.
4 Places
130
24
3
26
125 77 171
320
206
9.53
30.2
137
120
113
152.35Dia.
83
50
161.6
152.40
38.05 Dia.
42.36
42.18
127
Tank Port
Rc3/8 Thd.
38.10
Primary Pressure
Gauge Connection for 22 21.5 Dia. Through R22
Pump Discharge Pres. 58.7 39 Dia. Spotface 161.6
Rc1/4 Thd. 23 (Rear Side)
M10 Thd. 17 Deep 4 Places
4 Places 238.5
Discharge Port Filling Port
25 Dia. 299.5 (27 Hex. Head Plug Furnished)
Case Drain Port 2 Eye Bolt
5 Hex. Soc. M10
Suction Port
48 Dia.
77.8
M12 Thd. 19 Deep
4 Places
42.9
★1. Use either port of two drain ports at your option. Keep the remaining
port plugged. 270
★2. Case drain port is available for use when draining hydraulic fluid
from pump casing. View Arrow X
★3. Cable Applicable:
Outside Dia......8-10 mm
Conductor Area......Not Exceeding 1.5 mm2
DIMENSIONS IN
Foot Mtg. : A90-LR04*S MILLIMETRES
22 Dia. Through
43 Dia. Spotface
4 Places
25
140
24
3
375
A Series
(For Pres. Control)
1
Manual Pressure 400 Drain Port (Both Sides) Air Vent
Adj. Screw Rc3/4 Thd. 3 Hex. Soc. 216.5
3 Hex. Soc. 280.5 112 3 Places
189
INC. Manual Flow Adj. Screw
249.5 23
3 Hex. Soc. 160 112 Surface of Suction Port
INC.
Air Vent 225 72 72
3 Hex. Soc. Pilot Port Rc1/4 Thd. Safety Valve
3 Places 13 Pressure Adj. Screw
168 Secondary Pressure Gauge 85.3 3 Hex. Soc.
3 Connection for Pump
Cable Departure INC.
89 Discharge Pressure
(For Flow Control)
Rc1/4 Thd. 11.14
Tank Port 70 11.11
Rc3/8 Thd.
208
137
30.2
120
110
152.40 Dia.
83
50
228.6
152.35
49.39
49.21
44.40 Dia.
141
Primary Pressure
44.45
332
Filling Port
2 (27 Hex. Head Plug Furnished)
Case Drain Port
5 Hex. Soc. Eye Bolt
M10
Suction Port
48 Dia.
77.8
DIMENSIONS IN
Foot Mtg. : A145-LR04*S MILLIMETRES
22 Dia. Through
43 Dia. Spotface
4 Places
187.3
29
30
438
■ Performance
Input Signal for Input Signal for Characteristics
Flow Control Pressure Control
Amplifier
(S ← Input Voltage → L)
Proportional Solenoid
Output Flow→
Pressure Sensor
Control Valve ★1 ★2
Pressure
(S ← Input Voltage → L)
★1. Unloading pressure when input
Control Piston
signal is 0 V.
★2. Safety valve setting pressure
Graphic Symbols
Safety valve
A16/A22/A37/A45/A56
M
O
A70/A90/A100/A145
■ Model Number Designation
A45 -F R 04E 16M S -60 -10
A70 -F R 04E 16M A -60 -60
Type of
Direction of Control Pressure at Compensation Design
Series Number Mounting Control Type Outboard Port Position
Rotation Input Signal is 5 V Number★3 Number
Pump
A45 None : Axial Port
60 10
(45.0 cm3/rev) S : Side Port
A16 —— 06 42
(15.8 cm3/rev)
( )
A22 Viewed
Use the same 11 42
(22.2 cm3/rev) L:
from Shaft
A37 Foot measure of the
End 04E: 60 42
(36.9 cm3/rev) Mtg. control pressure as
Proportional None★2
A56 shown on the right,
Pressure & 60 42
(56.2 cm3/rev) 6.9 MPa specify
Flow Control
F: within the range of ——
A70 R: Type
Flange maximum 60 60
(70.0 cm3/rev) Clockwise★1
Mtg. operating pressure
A90 (Normal)
60 60
(91.0 cm3/rev) A ★2
A100 B ★2
60 10
(100 cm3/rev)
A145
60 60
(145 cm3/rev)
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
★2. These pumps, except A16/A22/A45 types, can be connected to outboard pumps.
- A37/A56 type (outboard pump connection symbol: None): spigot diameter: 82.55 mm (A16, A22, and PV2R1).
- A70/A90/A100/A145 type (outboard pump connection symbol: "A"): spigot diameter:82.55 mm (A16, A22, and PV2R1).
- A70/A90/A100/A145 type (outboard pump connection symbol: "B"): spigot diameter:101.6 mm (A37 and PV2R2).
★3. Amplifier Compensation Number may differ according to the main machine conditions. Consult Yuken for detail.
■ Specifications
Model Numbers
A16 A22 A37 A45 A56 A70 A90 A100 A145
Descriptions
A Series
Geometric Displacement cm3/rev 15.8 22.2 36.9 45.0 56.2 70.0 91.0 100 145
Rated ★2
16 16 16 16 16 25 25 21 25
Operating Pressure MPa
Intermittent★1 21 16 21 17.2 21 28 28 21 28
Shaft Speed Range r/min 600 - 1800
50 Hz Pin 28.4 40.0 66.4 81.0 101 126 163 180 261
Max. Flow★3 L/min
60 Hz Pin 23.7 33.3 55.4 67.0 84.3 105 136 150 217
Flow Control
Repeatability 1 % or less
Input Signal Specified Control Pressure / 5 V DC
Coil Resistance Ω(@20℃) 10
Input Impedance Flow Control : 10 kΩ Pressure Control : 10 kΩ
Supply Electric Power 24 V DC (21 - 28 V Included Ripple)
Power Input (Max.) W 30
Flow 5 V DC / Max. Flow (50 Hz Pin)
Output Signal
Pressure 5 V DC / Specified Control Pressure
Alarm Signal Output (Open Collector) Voltage : Max. 30 V DC Current : Max. 40 mA
Ambient Temperature ℃ 0 - 50 (With Circulated Air)
Flange Mtg. 20.5 20.5 32 32 39 64 76.5 76.5 96.4
Approx. Mass kg
Foot Mtg. 22.7 22.7 36.3 36.3 43.3 76 97 97 121.4
★1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
★2. When operating the pump exceeding the rated pressure, operating conditions are restricted.
Refer to page 31 for the details.
★3. Maximum flow differs to shaft speed.
The value listed above indicates shaft speed of 1800 r/min.
For other shaft speed calculate by the ratio of shaft speed.
"D2" Dia.
SK1106-★-91-60-10 - 14.7
SK1106-★-91-60-1001 14.8 - 19.6
A90-*R04E★*-60-60
Involute-serration SK1106-★-91-60-1002 19.7 - 22.6
SK1106-★-91-60-1003 22.7 -
( )
Dimensions Serration Size SK1106-★-100-60-10 - 14.7
Outboard Pump Part Number of mm Nominal Dia.×
A100-*R04E★-60-10 SK1106-★-100-60-1001 14.8 - 19.6
Connection Symbol Coupling Ass'y No. of Teeth×
"D1" "D2" Mojule SK1106-★-100-60-1002 19.7 - 21.0
A37/A56 None SK1106-★-145-60-10 - 14.7
098-PK412588-6 27 19.5 18.75×24×0.75 SK1106-★-145-60-1001 14.8 - 19.6
A70/A90/ “A” A145-*R04E★*-60-60
SK1106-★-145-60-1002 19.7 - 22.6
A100/A145 “B” 098-PK412623-1 36 26 25×24×1
SK1106-★-145-60-1003 22.7 -
Note 1. The symbol "★", shown with pump and amplifier model
● Selecting an Outboard Pump Type numbers, is the control pressure at input signal of 5 V.
2. Cable for pump-amplifier connection is not included. See Page
The maximum torque of outboard pumps is limited by shaft
81 for details on ordering cables.
and coupling assembly strength. When determining the
outboard pump type, the value of the displacement times
the pressure for a particular pump should not exceed the ■ Instructions
value shown in the table below. ● Input Signal
The pump is on unload condition when the pump is
②Outboard Pump
Pump ①Inboard Pump and q2×P2 operated without input signal voltage.
Model Outboard Pump ● Electric Source
Outboard pump connection symbol
No. (q1×P1)+(q2×P2) Always turn off electric source whenever the connector for
"None"/"A" "B"
swash plate tilt angle sensor is removed.
A37 900 and less
—— ● Compensation of Pump Maximum Regulated Flow at Frequency
A56 1742 and less If the same maximum flow is required at 50 Hz or 60 Hz,
A70 2408 and less 519 and less 935 and less connect short plug in the amplifier to 60 Hz at the place
A90/A100 4348 and less 977 and less where supplied frequency is 60 Hz. At this condition,
A145 4739 and less 951 and less maximum flow comes to the same value at 50 Hz.
If short plug is used at 60 Hz without making the change,
・q1, q2 : Displacement cm3/rev
・P1, P2 : Pressure MPa maximum flow increased in proportion to frequency.
・For selection of the appropriate pump, both values, ① and ②, should
be satisfied.
A Series
100 1800 r/min
Output Flow L/min
16 60
40
8
20
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC
● A22 ● A70
45 150
40 1800 r/min
125 1800 r/min
Output Flow L/min
75
20
50
10
25
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC
● A37 ● A90
80 175
1800 r/min
1800 r/min 150
Output Flow L/min
60 1500 r/min
1500 r/min
Output Flow L/min
125
40 100
75
20
50
0 1 2 3 4 5 25
Input Signal V DC
0 1 2 3 4 5
● A45
Input Signal V DC
90 ● A100
80 1800 r/min 180 1800 r/min
1500 r/min 160
Output Flow L/min
60 1500 r/min
Output Flow L/min
120
40
80
20
40
0 1 2 3 4 5
Input Signal V DC 0 1 2 3 4 5
Input Signal V DC
Note: Pump characteristics at 1800 r/min is the same as those at
1500 r/min where frequency is compensated.
(Refer to page 74.) ● A145
280
1800 r/min
240
Output Flow L/min
160
Specified Pressure
21 21 MPa 120
A**−FR04E21M
20 80
Full Cut-off Pressure MPa
A**−FR04E16M 40
16 16 MPa
0 1 2 3 4 5
12 Input Signal V DC
8 8 MPa
4
A**−FR04E8M
Refer to page 35 to 42 for performance characteristics of pressure
compensator type excluding characteristics appeared on this catalogue.
As for A45, contact us for details.
0 1 2 3 4 5
Input Signal V
19.02 Dia.
4.79
162
4.76
8 Places
21.24
21.08
19.05
96
82.50 Dia.
18
11
47.6
47.6
82.55
78
Suction Port Discharge Port
R12
19 Dia. 19 Dia.
22.2 22.2 12 106
172 130
32.5 32.5 95 Dia.
★1. Install the pump so that the “Filling Port” is at the top.
★2. Do not touch the screw because it is adjusted at the time of shipment.
★3. For cable connection with amplifiers, see page 81.
Plain Washer
X 7.97 Suction Port
166
7.94 32 Dia.
31.75
35.32
35.14
105
25
14
58.7
58.7
101.60
90
Discharge Port
32 Dia. M10 Thd. 19 Deep
M10 Thd. 19 Deep 30.2 12 146 R14 30.2 4 Places
4 Places 178.5 174 178.5
Outboard Pump Position 252.5
120 Dia.
★2
★2
★1. Install the pump so that the “Filling Port” is at the top.
★2. Do not touch the screw because it is adjusted at the time of shipment.
★3. For cable connection with amplifiers, see page 81.
View Arrow X
A Series
Cable Departure★3 Air Vent
Cable Applicable : 3 Hex. Soc.
Outside Dia. ..... 8 - 10 mm Filling Port★1
Conductor Area .....Not Exceeding 1.5mm2 (22 Hex. Head Plug Furnished)
Pressure Sensor Connector Drain Port
263.5 59
★2 Rc1/2 Thd. 151.5 149
30 9.5
★2
32
22.20 Dia.
6.38
Suction Port Discharge Port
166
6.35
25.01
24.85
32 Dia. 32 Dia.
22.23
105
101.55 Dia.
X
58.7
58.7
101.60
25
14
90
M10 Thd. 19 Deep
8 Places 12
36 36 146 R14
195
30.2 30.2 174
120 Dia.
Tilt Angle Sensor Connector
★1. Install the pump so that the “Filling Port” is at the top.
★2. Do not touch the screw because it is adjusted at the time of shipment.
View Arrow X ★3. For cable connection with amplifiers, see page 81.
DIMENSIONS IN
Side Port Type MILLIMETRES
263.5 59
151.5 149
166
58.7
90
30.2 86 86
178.5
Surface of Discharge Port Surface of Suction Port
31.70 Dia.
7.97
191
7.94
35.32
35.14
31.75
Hex. Hd. Screw
101.55 Dia.
90
25
14
58.7
58.7
101.60
R14
98
Discharge Port
32 Dia. Suction Port
M10 Thd. 19 Deep 30.2 12 146 30.2 35 Dia.
4 Places 191 174 191 M10 Thd. 19 Deep
Outboard 265 4 Places
120 Dia.
Pump Position
★3
★3
★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For cable connection with amplifiers, see page 81.
View Arrow X
X Suction Port
207.5
7.94
Hex. Hd. Screw 38 Dia.
35.32
35.14
31.75
126.95 Dia.
90
69.9
52.4
127.00
180
18
YUKEN
118
Discharge Port
26 Dia. M12 Thd. 19 Deep
35 Dia. Spotface
M10 Thd. 17 Deep 26.2 18 181 35.7 4 Places
(Rear Side)
4 Places 246.5 2 Places 211 246.5
Outboard Pump 305.5
Position Case Drain Port★3
★5 5 Hex. Soc.
★3 ★3 ★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option.
Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
View Arrow X ★4. For cable connection with amplifiers, see page 81.
★5. If you do not use the special sequence valve, plug the port (FP-SC-1/32).
● Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 47 for the dimensions of mounting bracket.
A Series
Cable Departure★4 Air Vent
Cable Applicable : 3 Hex. Soc. Filling Port★1
Outside Dia. ..... 8-10 mm (27 Hex. Head Plug Eye Bolt
Drain Port ★2
Conductor Area Rc3/4 Thd. 2 Places 117.5 157 Furnished) M10
.....Not Exceeding 1.5mm2 Tilt Angle Sensor
359 95 105 105
Connector
End Cover 119.5 23 Surface of Drain Port 68 68 Surface of Drain Port
(with Plug) Pressure Sensor
Seal Cover 13
Connector
63
Plain Washer
Suction Port
38.05 Dia.
X
217
Hex. Hd. Screw 48 Dia.
42.36
42.18
9.56
38.10
152.35 Dia.
113
9.53
161.6
77.8
58.7
152.40
YUKEN
127
Discharge Port
32 Dia. 21.5 Dia. Through
M10 Thd. 19 Deep 30.2 23
39 Dia. Spotface
161.6 R22 42.9 M12 Thd. 19 Deep
4 Places 270 (Rear Side) 270 4 Places
Outboard Pump 324 4 Places
Position
★5 Case Drain Port★3
5 Hex. Soc.
★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option.
★3 ★3
Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For cable connection with amplifiers, see page 81.
★5. If you do not use the special sequence valve, plug the port (FP-SC-1/32).
View Arrow X
11.14
219
★3
152.35 Dia.
110
228.6
58.7
77.8
152.40
YUKEN
Suction Port
141
Discharge Port
48 Dia.
32 Dia.
M10 Thd. 19 Deep 30.2 24 21.5 Dia. Through 228.6 42.9 M12 Thd. 19 Deep
R22 4 Places
4 Places 299.5 39 Dia. Spotface (273) 299.5
Outboard Pump 357.5 (Rear Side)
4 Places
Position
379.5:A145-FR04E*A ★5
383 :A145-FR04E*B
SK1106-★-*-*-10**
● Specifications ● Detail of Connector
Model No. Connector Name of Signal
SK1106-★-*-*-10**
Description CN1 1
Output to pilot valve solenoid
Solenoid 2
Applicable Coil
10 Ω (20℃)
Resistance CN2 1 0 [V] (0 V)
Input Impedance 10 kΩ (PIN, QIN) Power 2 +24 [V] (24 V)
24 V DC Supply 3 0 [V]
Power Supply
(21 - 28 V Included Ripple) 1 +5 [V]
Power Input (Max.) 30 W CN3 Power Supply for Sensor
2 0 [V]
Max. Flow / 5 V (QIN) Pres.
Input Signal 3 Input Signal - Sensor
Specified Pres. / 5 V (PIN) Sensor
4 0 [V]
Output Signal for Sensor 5 V / Max. Flow (SMQ)
1 +8 [V]
Monitor 5 V / Specified Pres. (SMP) Power Supply for Sensor
CN4 2 0 [V]
Ambient Temperature 0 - 50 ℃ Tilt
3 Input Signal - Sensor
Approx. Mass 450 g Angle
Sensor 4 0 [V]
5 —
1 Input Signal - Flow (Qin)
2 Input Signal - Common (COM)
CN5
Input/ 3 Input Signal - Pres. (Pin)
Output 4 Output Signal - Sensor Monitor P (SMP)
Signal
5 Output Signal - Sensor Monitor Q(SMQ)
6 0 [V]
Connector
15
CN1
Solenoid POWER
CN1
CN2 CONTROLLER
Power Supply 電 源/POWER SUPPLY
CN2
Frequency
1
(5A) Q. COMP
165
140
CN3 圧力
P. SPAN L. Q. C
Q. SPAN Q. DOT
MODEL TP1
SK1106-***-***-**-10
AMP. MFG NO.
EK411027-6
Input/
MADE IN JAPAN
Output
5
Signal
92 View with the Cover Removed
100
48
A Series
The cable assemblies are not included in the pump assembly. Purchase separately with model number described in the
below table if required.
センサ
ソレノイド
電 源
圧 力
信 号
斜板角
★1. Cable assemblies are available. When ordering, specify the cable ass'y model numbers from the table below.
■ Performance
Input Signal for Input Signal for Characteristics
Pressure Control Flow Control
Amplifier
L)
Proportional Solenoid
Pressure
Input Voltage
Sensor Control
Output Flow
Valve
1 2
(S
Pressure
(S Input Voltage L)
Control
Piston
1. Unloading pressure when input
signal is 0 V.
2. Safety valve setting pressure
Safety valve
( )
None:
A22
Viewed Axial Port 11 43
(22.2 cm3/rev) F:
Flange from Shaft ——
A37 04EH:
End S: 01 43
(36.9 cm3/rev) Mtg. "OBE" Type
Control Pressure at Input Side Port
A56 Proportional
Signal is 5 V 02 43
(56.2 cm3/rev) Pressure &
( )
(Refer to above Table)
A70 L: Flow Control
R: Viewed 60 61
(70.0 cm3/rev) Foot Type
Clockwise★1 from Shaft
A90 Mtg. (Normal) S:
End 60 61
(91.0 cm3/rev) Side Port
R: Right
A145 L: Left 60 61
(145 cm3/rev)
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
★2. Amplifier Compensation Number may differ according to the main machine conditions. Consult Yuken for detail.
■ Specifications
Model Numbers
A16 A22 A37 A56 A70 A90 A145
Descriptions
A Series
Geometric Displacement cm3/rev 15.8 22.2 36.9 56.2 70.0 91.0 145.0
Rated ★2
16 16 16 16 25 25 25
Operating Pressure MPa (PSI)
Intermittent★1 21 16 21 21 28 28 28
Shaft Speed Range r/min 600 - 1800
Max. Flow★2 L/min 28.4 40.0 66.4 101.2 126.0 163.0 261.0
Min. Pres. Required
MPa 2.0
Flow for Flow Adj.
Control Hysteresis 1 % or less
Repeatability 1 % or less
Input Signal Max. Flow / 5 V DC
Min. Adjustment
MPa 0.7
Pressure
Pressure
Hysteresis 1 % or less
Control
Repeatability 1 % or less
Input Signal Specified Control Pressure / 5 V DC
Coil Resistance Ω [@ 20℃] 10
Input Impedance Flow Control : 10 kΩ Pres. Control : 10 kΩ
Supply Electric Power 24 V DC (21 - 28 V Included Ripple)
Power Input (Max.) W 30
Flow 5 V DC / Max. Flow
Output Signal
Pressure 5 V DC / Specified Control Pressure
Alarm Signal Output (Open Collector) Voltage : Max. 30 V DC Current : Max. 40 mA
Ambient Temperature ℃ 0 - 50 (With Circulated Air)
Flange Mtg. 20.7 20.7 32.2 39.2 64 76.5 98
Mass kg
Foot Mtg. 22.9 22.9 36.5 43.5 76 97 123
★1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
★2. When operating the pump exceeding the rated pressure, operating conditions are restricted.
Refer to page 31 for the details.
★3. Maximum flow differs to shaft speed.
The value listed above indicates shaft speed of 1800 r/min.
For other shaft speed calculate by the ratio of shaft speed.
■ Instructions
● Input Signal
The pump is on unload condition when the pump is operated without input signal voltage.
● Electric Source
Always turn off electric source whenever the connector for swash plate tilt angle sensor is removed.
● Compensation of Pump Maximum Regulated Flow at Frequency
If the same maximum flow is required at 50 Hz or 60 Hz, connect short plug in the amplifier to 60 Hz at the place where supplied
frequency is 60 Hz. At this condition, maximum flow comes to the same value at 50 Hz.
If short plug is used at 60 Hz without making the change, maximum flow increased in proportion to frequency.
● Painting on Amp. Box and Solenoiod
To maintain suitable radiation effect, the amp. box and the solenoid of the control valve should not be painted.
● A16 ● A56
120
32
1800 r/min 100 1800 r/min
16 60
40
8
20
0 1 2 3 4 5
0 1 2 3 4 5
Input Signal V DC Input Signal V DC
● A22 ● A70
45 150
40 1800 r/min 125 1800 r/min
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC
● A90
● A37
175
1800 r/min
80
Output Flow L / min 150
1500 r/min
125
1800 r/min
Output Flow L / min
60 100
1500 r/min
75
40
50
20 25
0 0 1 2 3 4 5
1 2 3 4 5
Input Signal V DC Input Signal V DC
● A145
280
1800 r/min
240
Output Flow L / min
1500 r/min
200
Note: Pump characteristics at 1800 r/min is the same as those at 1500 r/min 160
where frequency is compensated. 120
(Refer to page 74.) 80
40
0 1 2 3 4 5
Input Signal V DC
■ Full Cut-off Pres. vs. Input Signal
28 A*-*R04EH28M 28 27.5MPa
{280kgf/cm2}
Full Cut-off Pressure MPa
A*-*R04EH280
24 24
A*-*R04EH200
20 A*-*R04EH20M 20 19.6MPa
{200kgf/cm2}
16 A*-*R04EH16M 16 15.7MPa
{160kgf/cm2}
12 12 A*-*R04EH160
8 A*-*R04EH8M 8 7.8MPa
{80kgf/cm2}
4 4 A*-*R04EH80
0 1 2 3 4 5 0 1 2 3 4 5
Input Signal V DC Input Signal V DC
NOTE {kgf/cm
: 2
}
is reference only.
Refer to page 35 to 42 for performance characteristics of
pressure compensator type excluding characteristics
appeared on this catalogue.
A Series
A22-FR04EH* 221 6.5 Filling Port
59 ( 22 Hex. Head Plug Furnished)
150.5
Electrical Conduit Connection 26.5
144
G 1/2 Thd. Drain Port Rc3/8 Thd.
25
2
See
Discharge Port
173
138
19 Dia.
21.24
21.08
X
251
96
47.6
19.05 Dia.
82.55 Dia.
19.02
82.50
Suction Port 22.2 M10 Thd. 17 Deep 12
19 Dia. 65 8 Places 172
145 94
★1. Install the pump so that the "Filling Port" is at the top.
★2. Do not touch the screw because it is adjusted at the time of shipment. 4.79
4.76
★3. For detail of amplifier, refer to page 90.
18
Port mounting dimensions are the same as those of pressure
R12
compensator model. Refer to page 44 for port mounting
95 Dia.
dimensions. 106
Discharge Port
177
142
32 Dia.
267
105
X
58.7
22.23 Dia.
25.01
24.85
101.60 Dia.
22.20
30.2 12
32 Dia. 8 Places
72 195
149 101
★1. Install the pump so that the "Filling Port" is at the top.
★2. Do not touch the screw because it is adjusted at the time of shipment. 6.38
★3. For detail of amplifier, refer to page 90. 6.35
274 62
256 9.5
Air Vent 3 Hex. Soc.
152.5 50.5
3
See
40
202
Discharge Port
167
32 Dia.
X
300
90
58.7
31.75 Dia.
35.52
35.14
101.60 Dia.
Suction Port
31.70
M10 Thd. 19 Deep
35 Dia.
101.55
8 Places 12
30.2
76 207
163.5 116
41 49
7.97
7.94
25
14
R14
120 Dia.
146
174
View Arrow X
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining
port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For detail of amplifier, refer to page 90.
A Series
Surface of Drain Port
107 157
314 62 95 95
40
7.97
Plug 5
213.5
7.94
2 Hex. Soc.
179.5
X
14
127.00 Dia.
90
114.4
52.4
180
126.95
18
118
35.32
35.14
31.75 Dia.
Discharge Port
26 Dia.
31.70
35 Dia. Spotface
M10 Thd. 17 Deep (Rear Side)
4 Places 26.2 16 2 Places 114.4 27 Dia. Spotface
(Rear Side)
18 134 4 Places
246.5 181
306.5 211
Suction Port
38 Dia.
★1. Install the pump so that the "Filling Port" is at the top.
View Arrow X
★2. Use either port of two drain ports at your option. Keep the remaining
port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For detail of amplifier, refer to page 90.
★5. If you use the special sequence valve, remove the plug.
223
2 Hex. Soc.
189
9.53
X
113
152.40 Dia.
161.6
58.7
152.35
127
38.10 Dia.
Discharge Port
42.36
42.18
39 Dia. Spotface
M10 Thd. 19 Deep (Rear Side) R22
4 Places 30.2 22 4 Places 161.6
23 105 105
270
Surface of Discharge Port Surface of Suction Port
324
Eye Bolt
◦Amplifier Direction "R": M10
Filling Port 1
A90-FR04EH*RS (27 Hex. Head Plug Furnished)
3
77.8
Suction Port
48 Dia.
View Arrow X
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For detail of amplifier, refer to page 90.
★5. If you use the special sequence valve, remove the plug.
A Series
Surface of Electrical Conduit Connection Surface of Drain Port
Plug 5
2 Hex. Soc.
225
191
11.14
X
110
152.40 Dia.
11.11
228.6
58.7
152.35
44.45 Dia.
49.39
49.21
141
Discharge Port
32 Dia.
44.40
Eye Bolt
◦Amplifier Direction "R": M10
A145-FR04EH*RS Filling Port 1
(27 Hex. Head Plug Furnished)
3
77.8
Suction Port
48 Dia.
View Arrow X
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For detail of amplifier, refer to page 90.
★5. If you use the special sequence valve, remove the plug.
60Hz
50Hz
24 V
Compensation Cartridge
FUSE
0V
ALM ALM SMQ SMP Q IN C P IN CH
C S
SPARE
FUSE
Terminal Name
P IN Input Signal, Pressure (+)
C Input Signal (COM)
Q IN Input Signal, Flow (+)
SMP Sensor Monitor Output, Pressure
SMQ Sensor Monitor Output, Tilt Angle
0V
Power Supply
24 V
ALM S Alarm Output
ALM C Alarm Output (COM)
CH Output Current Check (to COM)
Note 1. For "SENSOR MONITOR" terminal, external instruments
should have input impedance of more than 10 kΩ.
2. For "CH" terminal, external instruments should have input
impedance of more than 10 kΩ.
3. Volume adjustment of "DITHER", "GAIN", "CMG", "FMG"
and "LQC" is made at the time of shipment.
Adjustment at the customer is not required.
4. Use shielded cable for "Input" connection.
The ground of the shielded cable must be connected to input
signal side.
● Circuit Schematic
ALARM P SENSOR
SIG COM MONITOR
PRESS.
SENSOR
P IN
A
P GAIN ALARM
C
LQC
Q IN
A
CH
D CMG
OSC
DITHER
POSITION
SENSOR
FMG
24 V 0V Q SENSOR
MONITOR
A Series
Graphic Symbol ■ Performance Characteristics
QH
PH
Output Flow
QL
PL
M PL PH
O
Pressure
■ Specifications
Deliverry Volume Adj. Range Operating Pressure Shaft Speed Range
Geometric
cm3/rev MPa r/min
Model Numbers Displacement
Large Displacement Small Displacement
cm3/rev Rated Intermittent Max. Min.
(QH) (QL)
A16-*-R-05-**-S-K-32 15.8 2.6-15.8 2.6-11.1 16 21
A37-*-R-05-**-S-K-32 36.9 4.1-36.9 4.1-20.1 16 21 1800 600
A56-*-R-05-**-S-K-32 56.2 3.4-56.2 3.4-25.1 16 21
T P SOL a
SOL“OFF”
B A a QH
Output Flow
PL PL SOL“ON”
QL
PH PH
PL PH
Pressure
M M
O O
A16/A22/A37/A56 A70/A90/A145
■ Specifications
Deliverry Volume Adj. Range Operating Pressure Shaft Speed Range
Geometric cm3/rev MPa r/min
Model Numbers Displacement
cm3/rev Large Displacement Small Displacement
Rated Intermittent Max. Min.
(QH) (QL)
A16-*-R-06-**-S-K-*-33 15.8 2.6 - 15.8 2.6 - 11.1 16 21
A22-*-R-06-**-S-K-*-33 22.2 3.7 - 22.2 3.7 - 15.5 16 16
A37-*-R-06-**-S-K-*-33 36.9 4.1 - 36.9 4.1 - 20.1 16 21
A56-*-R-06-**-S-K-*-33 56.2 3.4 - 56.2 3.4 - 25.1 16 21 1800 600
A70-*R06S*-60 70.0 36 - 70.0 3 - 70.0 25 25
A90-*R06S*-60 91.0 56 - 91.0 3 - 70.0 25 25
A145-*R06S*-60 145 83 - 145 3 - 145 25 25
(Viewed
Shaft End ) Two-Pressure
A100, A120
F: Flange from 06: A200, A240
A22
Mtg. B: 2.5 - 7 B: 2.5 - 7 K: 33
(22.2 cm3/rev) S: DC
Two-Flow C: 2.5 - 16 C: 2.5 - 16 Keyed
A37 Side Port D12, D24
L: Foot R: Clockwise Control Type by H: 2.5 - 21 H: 2.5 - 21 Shaft 33
(36.9 cm3/rev) D48
Mtg. (Normal) Solenoid Valve
A56 R(AC→DC Rectifild)
R100, R200 33
(56.2 cm3/rev)
A70 AC
60
( )
(70.0 cm3/rev) A100, A120
F: Flange Viewed from 06: A200, A240
Mtg. Shaft End Two-Pressure
A90 S: DC
Two-Flow 60
(91.0 cm3/rev) Side Port D12, D24
L: Foot R: Clockwise Control Type by
D48
Mtg. (Normal) Solenoid Valve
A145 R(AC→DC Rectifild) 60
(145 cm3/rev) R100, R200
A Series
Graphic Symbol ■ Performance Characteristics
Output Flow
M
O
Pressure
■ Specifications
Operating Pressure Shaft Speed Range Approx. Mass
Geometric Minimum Minimum
MPa r/min kg
Model Numbers Displacement Adj. Flow Adj. Pres.
cm3/rev Flange Foot
cm3/rev Rated★2 Intermittent★1 MPa Max. Min.
Mtg. Mtg.
A10-FR07-12 10.0 2 16 21 2.0 1800 600 8.5 10.7
A16-*-R-07-*-K-32 15.8 4 16 21 1.2 1800 600 21 23.2
A22-*-R-07-*-K-32 22.2 6 16 16 1.2 1800 600 21 23.2
A37-*-R-07-*-K-32 36.9 10 16 21 1.2 1800 600 29 33.3
A56-*-R-07-*-K-32 56.2 12 16 21 1.2 1800 600 36 40.3
A70-*R07S-60 70.0 36 25 25 2 1800 600 60.3 72.3
A90-*R07S-60 91.0 56 25 25 2 1800 600 77.5 98
A145-*R07S-60 145 83 25 25 2 1800 600 94 119
★1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
★2. When operating the pump exceeding the rated pressure, operating conditions are restricted.
Refer to page 31 for the details.
A70 -F R 07 S -60
Series Number Mounting Direction of Rotation Control Type Port Position Design Number
A10 F:
— 12
(10.0 cm3/rev) Flange Mtg.★2
A70
(70.0 cm3/rev) F:
(Viewed
Shaft End )
from
07: 60
Flange Mtg. Pilot Pressure Control Type
A90 R: Clockwise★1 Pressure Compensator S:
60
(91.0 cm3/rev) (Normal) Side Port
L:
A145 Foot Mtg.
60
(145 cm3/rev)
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
★2. When A10 pump is used as the foot Mtg., order the Mtg. Bracket kit shown below separately.
Refer to page 20 for dimensions of the Mtg. bracket.
★3. Please inquire for A220 separatery.
INC. 52.5 25
4.79
Flow Adj. Screw 4.76
13 Hex.
107
92
DEC.
65
82.50 Dia.
171
41
82.55
19.05 Dia.
21.24
21.08
11
19.02
2 3
Suction Port 10.5
25 25 93 Dia. 106
Rc1/2 Thd.
2 3 131
64.5 64.5 Discharge Port 130
Rc1/2 Thd. 156
159.5
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two suction and discharge ports at your option. Keep the remaining ports plugged.
★3. As the tightening torques of suction, discharge and drain port fittings, conform to the below.
Tightening Torque Nm
Model Numbers Suction Port &
Drain Port
Discharge Port
A10-FR07-12 65 - 75 40 - 50
A Series
A22-F-R-07-K
202
2
Pilot Port "PP"
Rc3/8 Thd. 187 44.5
59 6.5 1
Filling Port
(22 Hex. Head Plug Furnished)
26.5
Drain Port Rc3/8 Thd.
25 4.79
4.76
109
96
82.5
62
82.50 Dia.
187
18
12
82.55
X
21.24
21.08
19.02 Dia. R12
19.05
95 Dia.
12 106
172 130
188
Surface of Suction and Discharge Port
INC. ★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two pilot ports at your option.
Keep the remaining port plugged.
65
47.6
Suction Port
22.2 M10 Thd. 17 Deep
19 Dia. 8 Places
65
Discharge Port
19 Dia.
View Arrow X
225
210 59
2 1
Pilot Port "PP" 77 9.5 Filling Port
Rc3/8 Thd. (22 Hex. Head Plug Furnished)
30
Drain Port Rc1/2 Thd.
6.38
32 6.35
112
105
88.5
68
X
202
58.7
14
25
25.01
24.85
Dia.
22.23
22.20 R14
Dia.
120 Dia.
101.60
101.55
M10 Thd. 19 Deep
30.2 12 146
4 Places (Both Sides)
Discharge Port 32 Dia. 178.5 174
(Rear Side)
Suction Port 32 Dia. 202
INC.
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two pilot ports at your option.
71
86 86
View Arrow X
A Series
Fully Extended 262.5
237.5
2
Pilot Port "PP" 222.5 62
Rc3/8 Thd. Filling Port 1
50.5 9.5 (22 Hex. Head Plug Furnished)
2
43.5 Drain Port Rc3/4 Thd.
(Both Sides) Surface of Drain Port
41 49
7.97
40 7.94
138
97.5
90
77
X
236
58.7
25
14
31.70 Dia.
35.32
35.14
Dia.
31.75
R14
101.60
101.55
120 Dia.
M10 Thd. 19 Deep 30.2 12 146
4 Places (Both Sides)
Discharge Port 30 Dia. 191 174
(Rear Side)
Suction Port 35 Dia. 232
INC. ★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two pilot and drain ports at your option.
Keep the remaining ports plugged.
80
100 100
View Arrow X
40
X 7.97
7.94
180.5
182
14
Y
90
18
114.4
52.4
180
118
35 Dia. Spotface
35.32
35.14
31.70 Dia.
2 Places
127.00
126.95
19.5
M10 Thd. 17 Deep 26.2 114.4
4 Places 16
134
18
181
246.5
211
Surface of
Pilot Port "PP1"
2
Pilot Port "PP2"
316.5 Rc1/4 Thd.
165.5
INC. 69.9
246.5
View Arrow Y
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged.
★3. Case drain port is available for use when draining hydraulic fluid from pump casing.
A Series
2
Drain Port Rc3/4 Thd.
(Both Sides) Surface of Discharge Port Surface of Suction Port
95
105 105
119.5 23
Surface of Drain Port 68 68 Surface of Drain Port
13
63
X
190.5
190
9.56 Y
113
9.53
161.6
58.7
127
Dia.
42.36
42.18
22
30.2 R22
M10 Thd. 39 Dia. Spotface 161.6
19 Deep 23 (Rear Side)
4 Places 4 Places
270
Surface of Pilot Port "PP1"
3
Case Drain Port 2
5 Hex. Soc. Fully Extended Pilot Port "PP2"
376 Rc1/4 Thd.
341 Safety Valve Pres. Adj. Screw
Eye Bolt 14 Hex.
M10 268.5 INC.
2 Filling Port 1 Flow Adj. Screw
Pilot Port "PP1" (27 Hex. Head Plug Furnished)
Rc1/4 Thd. 17 Hex.
9.5 17.5 DEC.
170
88
77.8
Suction Port
48 Dia.
View Arrow X
42.9
View Arrow Y
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged.
★3. Case drain port is available for use when draining hydraulic fluid from pump casing.
112 112
Fully Extended 112
400.5 Surface of Drain Port 72 72 Surface of Drain Port
89 23
15
13
70
X
11.14
198.5
11.11
110
Y
228.6
58.7
Discharge Port
141
49.39
49.21
44.40 Dia.
152.35 Dia.
32 Dia.
21.5 Dia. Through
44.45
M10 Thd.
152.40
39 Dia. Spotface
19 Deep 30.2 24 (Rear Side) 228.6 R22
4 Places 4 Places
26 273
299.5
3
Case Drain Port
5 Hex. Soc.
Surface of
Eye Bolt Pilot Port "PP1"
Safety Valve Pres. M10 2
Adj. Screw 362.5 Pilot Port "PP2"
2
14 Hex. Rc1/4 Thd.
Pilot Port "PP1" INC.
24 290
Rc1/4 Thd. Flow Adj. Screw
17 Hex. Filling Port 1
DEC. (27 Hex. Head Plug Furnished)
Suction Port
48 Dia.
177
192
77.8
View Arrow X
M12 Thd. 19 Deep
4 Places
42.9
299.5
View Arrow Y
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged.
★3. Case drain port is available for use when draining hydraulic fluid from pump casing.
A Series
■ Performance Characteristics
Ou
t pu
tF
lo
w
Output Flow
Input Power
Input Power
Pressure
Graphic Symbol
PP P PP P
M M M M
O O O O
S DR S DR
■ Specifications
Operating Pres. Shaft Speed Range Approx. Mass
Geometric Minimum★2
MPa r/min kg
Model Numbers Displacement Adj. Flow
cm3/rev Flange Foot
cm3/rev Max. Max. Min.
Mtg. Mtg.
A16-*-R-09-*-*-K-32 15.8 ―― 21★1 1800 600 29.0 31.2
A37-*-R-09-*-*-K-32 36.9 ―― 21★1 1800 600 37.0 41.3
A56-*-R-09-*-*-K-32 56.2 ―― 21★1
1800 44.0 44.0 48.3
A70-*R09*S-60 70.0 36 25 1800 600 72.8 84.8
A145-*R09*S-60 145 83 25 1800 600 110 135
★1. Maximum Operating Pressure of A16/A37/A56 varies according to Input Power Setting. See Model Number Designation for details.
★2. Minimum Adjustment Flow of A70/A145 is absolutely minimum flow that can be adjusted with Flow Adjustment Screw.
A90 type pump (91 cm3/rev) is available. Ask Yuken for Details.
● A70/A145
A70 -F R 09 -A S -60
Direction of Design
Series Number Mounting Control Type Input Power Setting Direction of Port
Rotation Number
(Viewed
Shaft End )
A70 A : 15 kW C : 22 kW
F: Flange from 60
(70 cm3/rev) 09: Constant B : 18.5 kW D : 30 kW
Mtg.
Power A : 15 kW E : 37 kW S: Side Port
A145 Control B : 18.5 kW F : 45 kW
L: Foot R: Clockwise★1 60
(145 cm3/rev) Type C : 22 kW G : 55 kW
Mtg. (Normal)
D : 30 kW H : 75 kW
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
★2. Specify control pressure of A16/A37/A56 with lower than Maximum Operating Pressure depending on Input Power Setting
A Series
● A16 ● A70
30 200 40
20 5 150 30
Input Power kW
3.7 kW
Input Power kW
25
Output Flow 22 kW
3
2.2 kW 100 20
10 18.5 kW
2
15 kW
15
1
1.5 kW 30 kW
0 50 10
22 kW
0 3.5 7 10. 5 14 17. 5 21
Pressure MPa 18.5 kW 5
15 kW
0
0 10 20 30
Pressure MPa
● A37 ● A145
11 kW
60 Output Flow 12 300 75
Input Power 37 kW 70
50 10 45 kW
7.5 kW 60
Output Flow L/min
40 8
55 kW
5.5 kW 200 50
Output Flow L/min
30 6
Input Power kW
45 kW
20 4 40
37 kW
10 2 30
3.7 kW 30 kW
0 100
0 3.5 7 10. 5 14 17. 5 21 22 kW 20
Pressure MPa 30 kW
22 kW 10
0
0 10 20 30
Pressure MPa
● A56
100 20
Output Flow
Output Flow L/min
Input Power kW
80
60
10
40
20
3.7 kW
0
0 3.5 7 10. 5 14 17. 5 21
Pressure MPa
229 6.5
172 130
Drain Port
26.5 Rc3/8 Thd.
106
Fully Extended
25 4.79
4.76 R12
111
96
X
19.02 Dia.
12
21.24
21.08
18
78
82.55 Dia.
19.05
95 Dia.
82.50
12
252
63.5
Suction Port
19 Dia.
47.6
32.5 56
Discharge Port
G1/2 Thd.
94 87
View Arrow X
17
0.5 2.5
A Series
59
Filing Port 1 Drain Port Rc1/2 Thd.
9.5
(22 Hex. Head Plug Furnished) 101 101
30 32
Fully Extended
155
6.38
6.35
105
101.60 Dia.
7
101.55
25
14
22.23 Dia.
25.01
24.85
90
R14
22.20
12
Pressure Gauge Connection 195 146
for Pump Discharge Pressure
120 Dia.
Rc1/4 Thd. 228 174
282
27 Rc1/4 Thd.
Suction Port
30 Dia. Discharge Port
20 Dia. ★1. Install the pump so that the "Filling Port" is at the top.
85
★2. Do not touch the screw because it is adjusted at the time of shipment.
58.7
47.6
30.2 22.2
36 42
View Arrow X
DIMENSIONS IN
MILLIMETRES
Foot Mtg. : A37-L-R-09-*-K
14 Dia. Through
28 Dia. Spotface
4 Places
102
15
14
3
60 74 120
115 39 95 95
230
Filling Port 1
(22 Hex. Head Plug Furnished)
Drain Port 2 50.5 62
41 49
Rc3/4 (Both Sides)
43.5 9.5
Surface of Drain Port
40
Surface of Drain Port
7.97
161
7.94
X
101.60 Dia.
90
101.55
25
14
35.32
35.14
31.75 Dia.
98
R14
31.70
12
120 Dia.
207 146
240 174
Pressure Gauge Connection
for Pump Discharge Pressure 294 232
Rc1/4 Thd.
Surface of Suction Port
47.6
★3. Do not touch the screw because it is adjusted at the time of shipment.
M10 Thd. 19 Deep M10 Thd. 19 Deep
4 Places 4 Places
30.2 22.2
38 44
View Arrow X
DIMENSIONS IN
MILLIMETRES
Foot Mtg. : A56-L-R-09-*-K-32
14 Dia. Through
28 Dia. Spotface
4 Places
102
14
15
3
60 77 120
115 42 95 95
230
A Series
Fully Extended
351.5 62 27 Dia. Spotface
(Rear Side) 4 places
Drain Port 2 65 19.5 188 95 Surface of Suction Port
Rc3/4 Thd. (Both Sides)
M10 Thd. 17 Deep 9.5 Surface of Drain Port 73 73 Surface of Drain Port
4 Places
40
7.97
Y 7.94
180.5
182
X
18
90
114.4
26.2
180
31.75 Dia.
35.32
35.14
118
127.00 Dia.
31.70
14
Discharge Port
126.95
18 Dia. 35 Dia. Spotface
52.4 18 114.4
(Rear Side) 2 places
212.5 134
211
69.9
View Arrow Y
M12 Thd. 19 Deep
4 Places
Case Drain Port 4
35.7
5 Hex. Soc.
246.5
View Arrow X
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. Case drain port is available for use when draining hydraulic fluid from pump casing.
Drain Port 2
Input Power Setting Screw "A" 3
Fully Extended Rc3/4 Thd. (Both Sides)
397 112
Surface of Discharge Port 214 112 Surface of Suction Port
89 23
Surface of Drain Port 72 72 Surface of Drain Port
Discharge Port 13 11.14
32 Dia. 11.11
70
Fully Extended
30.2
246
198.5
X
110
57
228.6
YUKEN
44.45 Dia.
141
49.39
49.21
M10 Thd. 19 Deep
152.40 Dia.
4 Places 44.40
21.5 Dia. Through
152.35
58.7 24 228.6 R22
39 Dia. Spotface
(Rear Side)
299.5 4 Places 273
5 Hex. Soc.
Eye Bolt
INC.
M10 Pressure Adj. Screw
Filling Port 1 17 Hex.
(27 Hex. Head Plug Furnished) Flow Adj. Screw
17 Hex. DEC.
Suction Port
48 Dia.
77.8
299.5
View Arrow X
★1. Install the pump so that the "Filling Port" is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. Case drain port is available for use when draining hydraulic fluid from pump casing.
A Series
■ Specifications
Performance Characteristics
Output Flow Adj. Operating
Geometric Range Pressure Shaft Speed
cm /rev
3
MPa
Model Numbers Displacement Range QH
Large Small
Output Flow →
cm3/rev Displacement Displacement Rated Intermittent r/min
(QH) (QL) QL
■ Instruction QL
As the pump does not have Full-Cut off function, setting relief valve of PH pressure
(Maximum Pressure on circuit) for pump discharge line is absolutely required.
A16
32500
(15.8 cm3/rev) (Viewed from
F : Flange Mtg Shaft End)
A37 00 : Special
H : 1.2-21 K : Keyed Shaft 32500
(36.9 cm3/rev) ★ Control Type
L : Foot Mtg. R : Clockwise
A56 (Normal)
32500
(56.2 cm3/rev)
● A70-A145
A70 −F R 00 H S −60500
Direction of Pres. Adj. Range Design
Series Number Mounting Control Type Port Position
Rotation MPa Number
A70
(70.0 cm3/rev) (Viewed from
F : Flange Mtg Shaft End)
A90 00 : Special
H : 2-21 S : Side Port 60500
(91.0 cm3/rev) ★ Control Type
L : Foot Mtg. R : Clockwise
A145 (Normal)
(145 cm3/rev)
★ Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
Graphic Symbol
M
O
■ Specifications
Shaft Speed
Operating Pressure Approx. Mass
Geometric Min. Adj. Range
MPa kg
Model Numbers Displacement Flow r/min
cm3/rev cm3/rev Flange Foot
Rated Intermittent Max. Min.
Mtg. Mtg.
Outboard Pump 15.8 4 16 21
A1616-*R01*01**K-32 1800 600 35.5 37.7
Inboard Pump 15.8 4 16 21
Outboard Pump 15.8 4 16 21
A1622-*R01*01**K-32 1800 600 35.5 37.7
Inboard Pump 22.2 6 16 16
Outboard Pump 22.2 6 16 16
A2222-*R01*01**K-32 1800 600 35.5 37.7
Inboard Pump 22.2 6 16 16
Outboard Pump 15.8 4 16 21
A1637-*R01*01**K-32 1800 600 50 54.3
Inboard Pump 36.9 10 16 21
Outboard Pump 22.2 6 16 16
A2237-*R01*01**K-32 1800 600 50 54.3
Inboard Pump 36.9 10 16 21
Outboard Pump 15.8 4 16 21
A1656-*R01*01**K-32 1800 600 54.5 58.8
Inboard Pump 56.2 12 16 21
Outboard Pump 22.2 6 16 16
A2256-*R01*01**K-32 1800 600 54.5 58.8
Inboard Pump 56.2 12 16 21
Outboard Pump 15.8 4 16 21
A1670-*R01*01**-60 1800 600 77.5 89.5
Inboard Pump 70.0 36 25 28
Outboard Pump 22.2 6 16 16
A2270-*R01*01**-60 1800 600 77.5 89.5
Inboard Pump 70.0 36 25 28
Outboard Pump 36.9 10 16 21
A3770-*R01*01**-60 1800 600 86.5 98.5
Inboard Pump 70.0 36 25 28
Outboard Pump 15.8 4 16 21
A1690-*R01*01**-60 1800 600 88 108.5
Inboard Pump 91.0 56 25 28
Outboard Pump 22.2 6 16 16
A2290-*R01*01**-60 1800 600 88 108.5
Inboard Pump 91.0 56 25 28
Outboard Pump 36.9 10 16 21
A3790-*R01*01**-60 1800 600 100.5 121
Inboard Pump 91.0 56 25 28
Outboard Pump 56.2 12 16 21
A5690-*R01*01**-60 1800 600 107.5 128
Inboard Pump 91.0 56 25 28
Outboard Pump 15.8 4 16 21
A16145-*R01*01**-60 1800 600 109 134
Inboard Pump 145 83 25 28
Outboard Pump 22.2 6 16 16
A22145-*R01*01**-60 1800 600 109 134
Inboard Pump 145 83 25 28
Outboard Pump 36.9 10 16 21
A37145-*R01*01**-60 1800 600 121.5 146.5
Inboard Pump 145 83 25 28
Outboard Pump 56.2 12 16 21
A56145-*R01*01**-60 1800 600 128.5 153.5
Inboard Pump 145 83 25 28
A Series
01 C 01 C
Series Direction of Pres. Adj. Pres. Adj. Port Position of Shaft Design
Mounting Control Type Control Type
Number Rotation Range MPa Range MPa Outboard Pump Extension Number
A1616 B : 1.2- 7
(15.8/15.8 C : 1.2-16 32
cm3/rev) B : 1.2- 7 D : 1.2-21
C : 1.2-16
A1622 D : 1.2-21
(15.8/22.2 32
cm3/rev) B : 1.2- 7
A2222 C : 1.2-16
B : 1.2- 7
(22.2/22.2 32
C : 1.2-16
cm3/rev)
A1637 B : 1.2- 7 K:
(15.8/36.9 C : 1.2-16 Keyed 32
cm3/rev) H : 1.2-21 Shaft
A2237
B : 1.2- 7
(22.2/36.9 32
C : 1.2-16 B : 1.2- 7
cm3/rev)
C : 1.2-16
A1656 B : 1.2- 7 D : 1.2-21
(15.8/56.2 C : 1.2-16 32
cm3/rev) H : 1.2-21
A2256
B : 1.2- 7
(22.2/56.2 32
C : 1.2-16
cm3/rev)
A1670 B : 1.2- 7
(Viewed
Shaft End )
(15.8/70.0 F: C : 1.2-16 60
cm3/rev) from H : 1.2-21
Flange S:
A2270 Mtg. Side Port
B : 1.2- 7
(22.2/70.0 01: 01: 60
R: C : 1.2-16
cm3/rev) Pressure Pressure
Clockwise★1
A3770 Compensator Compensator
(Normal)
(36.2/70.0 Type Type 60
cm3/rev) B : 1.2- 7
L: None:
C : 1.2-16
A1690 Foot Axial Port
H : 1.2-21
(15.8/91.0 Mtg. 60
cm3/rev)
A2290
B : 1.2- 7
(22.2/91.0 60
C : 1.2-16
cm3/rev)
B : 1.2- 7
A3790 None:
C : 1.5-16
(36.9/91.0 Keyed 60
H : 1.8-21
cm3/rev) Shaft
K : 2.0-28
A5690 B : 1.2- 7
(56.2/91.0 C : 1.2-16 60
cm3/rev) H : 1.2-21
A16145
(15.8/145 60
cm3/rev)
A22145
B : 1.2- 7
(22.2/145 60
C : 1.2-16
cm3/rev)
A37145
(36.9/145 60
cm3/rev) B : 1.2- 7
C : 1.2-16
A56145 H : 1.2-21
(56.2/145 60
cm3/rev)
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
Graphic Symbol
M
O
B : 1.2- 7
A16R1 C : 1.2-16 32
D : 1.2-21
B : 1.2- 7
A22R1 32
C : 1.2-16 K:
Keyed
Shaft
A37R1 32
B : 1.2- 7
6, 8
C : 1.2-16
10, 12
D : 1.2-21
A56R1 F: 14, 17 32
Flange 19, 23
A70R1
Mtg.
(Viewed
Shaft End ) 01:
from 25, 31
(Viewed
Shaft End )
from
60
Pressure
R: Compensator B: 1.2- 7
Clockwise★1 Type C: 1.5-16 A: Up A: Up
A90R1 60
L: (Normal) H: 1.8-21
Foot K: 2.0-28
A145R1 Mtg. 60
None:
Keyed
Shaft
A70R2 60
B: 1.2- 7
41,47
C: 1.5-16
A90R2 56,59 60
H: 1.8-21
65
K: 2.0-28
A145R2 60
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
■ Specifications
Shaft Speed
Operating Pressure Approx. Mass
Geometric Range
MPa kg
Model Numbers Displacement r/min
A Series
cm3/rev Flange Foot
Rated Intermittent Max. Min.
Mtg. Mtg.
Outboard Pump Refer to the following table
A16R1-*R01*-AAK-32 1800 750 28.8 31.0
Inboard Pump 15.8 16 21
Outboard Pump Refer to the following table
A22R1-*R01*-AAK-32 1800 750 28.8 31.0
Inboard Pump 22.2 16 16
Outboard Pump Refer to the following table
A37R1-*R01*-AAK-32 1800 750 39 43.3
Inboard Pump 36.9 16 21
Outboard Pump Refer to the following table
A56R1-*R01*-AAK-32 1800 750 47 51.3
Inboard Pump 56.2 16 21
Outboard Pump Refer to the following table
A70R1-*R01*-AA-60 1800 750 66 78
Inboard Pump 70.0 25 28
Outboard Pump Refer to the following table
A90R1-*R01*-AA-60 1800 750 82 105
Inboard Pump 91.0 25 28
Outboard Pump Refer to the following table
A145R1-*R01*-AA-60 1800 750 102 129
Inboard Pump 145 25 28
Outboard Pump Refer to the following table
A70R2-*R01*-*AA-60 1800 600 72.5 84.5
Inboard Pump 70.0 25 28
Outboard Pump Refer to the following table
A90R2-*R01*-*AA-60 1800 600 91.5 112
Inboard Pump 91.0 25 28
Outboard Pump Refer to the following table
A145R2-*R01*-*AA-60 1800 600 112 137
Inboard Pump 145 25 28