: 2283
CONSULTING ENGINEERS Tel : ???? PAGE:
???? Fax :???? DATE: 31-Jan-2012
???? email: ???? DESIGN: SCH
LY
Use Directional Wind Speeds TRUE
N NE E SE S SW W NW
β 0 45 90 135 180 225 270 315 degrees
Tcat 2.5 2.5 3 3 3 3 3 2.5
V[R,u] = 45 45 45 45 45 45 45 45 m/s
N
M[d] = 0.90 0.80 0.80 0.80 0.85 0.95 1.00 0.95
M[z,cat] = 0.87 0.87 0.83 0.83 0.83 0.83 0.83 0.87
M[s] = 1.00 1.00 1.00 0.95
O 0.95 0.95 0.95 1.00
M[t] = 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
M[z,cat].M[s].M[t] = 0.87 0.87 0.83 0.79 0.79 0.79 0.79 0.87
V[sit,β,u] = 35.24 31.32 30.00 30.00 30.16 33.71 35.48 37.19 m/s
Maximum Expected wind speed at SITE for strength limit state = V[sit,β,u] = 37.19 m/s relative to building
E
ASSESSMENT OF BUILDING ORIENTATION AlternateValue 360
Bearing of Northern Most Face -19 (degrees from North, less than 90°) Orientation known 0
Building Face 1 2 3 4
PL
Site Design
Maximum Design wind speed for Building for strength limit state = V[des,Θ,u] = 37.19 m/s Vp = 30.4