ACM-7 self-contained downhole pressure and temperature gauge

Purpose.

ACM-7 designed to record pressure and temperature by the hydrodynamic studies in


the process of drilling and operation of oil and injection wells.

The tool measures pressure and temperature at set intervals of time and records the
digital information in an electronic non-volatile memory. The pressure sensor at the
same time is a temperature sensor.

After the measurement, the data is read into the computer for processing, analysis,
display (printer) in graphic or digital form and transfer to other programs.

ACM-7 has improved characteristics of pressure channel through the use of pressure
sensor "Keller" (Germany).

Technical characteristics
Parameter Value
Pressure channel (P)
Measuring range, kgf/sq.cm 0-250, 0-400, 0-600, 0-1000
The number of ADC bits 19
Absolute error*, kgf/sq.cm ±0.18
Drift of zero pressure by sharp heating (30 min.) from 20 to ±0.1
50°C, kgf/sq. cm
Hysteresis at room temperature, kgf/sq. cm ±0.02
The sensitivity of pressure (depending on operation mode), 0.001
kgf/sq cm
* the maximum absolute error for the range 0-600 kgf/sq cm
** 1 kgf/sq cm=0.098066 MPa
Temperature channel (T)
Measuring range, °C 0...+100, 0...+120, 0...+150
The number of ADC bits 13
Absolute error, °C ±1
Time constant, min, not more than 3
Tool memory
Amount of memory of the tool 4 MB (1 081 344 of measurement points) or 8 MB (2 162 688
of measurement points)
Filling time memory from 300 hours (cycle 1 sec) up to 1 239 days (cycle 99 sec)
The time of storage of information 10 years
Number of write cycles in the internal memory 100000
Time parameters
The response time (measurement period), sec 1-99
The variance in time of the internal clock per day, sec, not more ±5
than
Power supply
Power source Lithium battery 3.6 V
The minimum voltage, V 3
The current consumption in the storage mode, µA 40
Current consumption in operational mode (depending on the 0.043 (cycle 99 sec)
time cycle), mA 0.36 (cycle 1 sec)
The duration of the power source, the day 115 (cycle of 1 sec) 969 (cycle 99 sec) (when power supply
capacity 1000mAh)

1/2
LLC PKF GEOTEKH 452684, Russian Feleration, Bashkortostan, Neftekamsk city, Socialisticheskaya, 36B
E-mail: mail@geotekh.ru; tel.:+7 (34783) 4-85-26, 4-86-09 Product Catalog. Generation date: 04.02.2020

Parameter Value
Software
Switching on and off of the tool in the record mode using a
computer
The read data from the tool to the PC in any interval of time
worked
View the real values of pressure, temperature and voltage of the
power supply to test instrument
Setting the time cycle from 1 to 99 sec
View data on the computer screen in numerical and graphical
form
Conclusion the data obtained in the selected range to the printer
in numerical and graphic form
Save a received data in formats *.txt, *.las, *.xls (Excel)
Communication with PC USB2.0
Read the entire memory of the tool, min, not more 2
The reliability of the tool
The average repair time, h, not more 4
Average lifetime, years 5
Size
Length, mm от 300
Diameter, mm 20, 25, 30
Weight, kg, not more than 2

Modifications
Model Description
ACM-7-20 MPa/°С Channels: P, Tin. Pressure sensor Keller
ACM-7-30 MPa/°С Channels: P, Tin. Pressure sensor Keller.
ACM-7G-30 MPa/°С Channels: P, Tin. Pressure sensor Keller. Gas-resistant.
ACM-7T-30 MPa/°С Channels: P, Tout, Tin. Pressure sensor Keller. With
thermometer.
ACM-7TG-30 MPa/°С Channels: P, Tout, Tin. Pressure gauge Keller. Gas-resistant.
With thermometer.

2/2