(The HYDROSPLIT-M3 is a separate thermal energy computer that measures the amount of energy used to heat or cool the water supplied to piping systems, including large calibers, that do not allow the installation of the compact version. It connects to the pulse output of a meter to measure the volume of water used. The processing of the data regarding the difference between the temperature of the thermal agent at flow and return, as well as the data regarding the volume of water used by each user, allows the calculation of the amount of energy actually consumed. ) Separate heat/BTU calculator for measuring the amount of energy used for heating and/or cooling. Easily connectable to flow meters equipped with pulse output and used in systems with pipes larger than DN20 – ¾ “. The processing of the data on the difference between the temperature of the thermo- vector fluid supply and the return one (DT), combined with the data on the volume of the thermo-vector fluid used, allows accurate calculation of the amount of energy consumed. Approved according to the MID 2004/22/CE MI004 and the EN1434 standard. Technical Features
Environmental class A (E1; M1)
Temperature measuring range (Heating) 5 – 180 °C Temperature difference range (Heating) 3 – 150 K Temperature measuring range (cooling) 2 – 24 °C Calibration temperature 3 – 20 K Maximum measurable power 99 MW Temperature sensor PT 1000 Cable length for the temperature sensor 3 m / 10 m Power supply Litium battery / external power supply Max. Battery life (basic version) 10+1 years Protection degree IP52 Display level 6 Display LCD 8 digits + icons Energy load indicator MWh (GJ on request) Maximum cable length pulse emitter 2m 0.1 – 0.25 – 1.0 – 2.5 – 10 – 25 – 100 – 250 Input pulse rate litres 1 dedicated for the heating/cooling circuit Pulse input meter Class IA (default): Open Collector or reed Pulse input class contact, max 5Hz Display Pulse input maximum frequency 5Hz (MID approved) Installation site of flowmeter (Flow in) Return pipe (default), Supply pipe (optional) Supported vector fluid Water The most important indications of the Hydrosplit M3 heat meter are:
Current readout of heat consumption in GJ;
Current amount of heat / cooling energy consumed; 26-month indications of consumption of heat / cooling and C1 and C2 water meters with dates; Instantaneous flow of the heating medium; Cumulative volume of flow; Flow / return temperature and temperature difference Instantaneous energy consumption in kW; Operating hours of the device since the issuance of the conformity assessment; Indications of C1 and C2 water meters.